1
|
Wijayanti AD, Ardiansyah RD, Pratama AM, Haryanto A, Fitriana I. Validation method for determining enrofloxacin and tylosin levels in broiler liver, kidney, and muscle using high-performance liquid chromatography. Vet World 2022; 15:268-274. [PMID: 35400941 PMCID: PMC8980376 DOI: 10.14202/vetworld.2022.268-274] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2021] [Accepted: 01/10/2022] [Indexed: 11/16/2022] Open
Abstract
Background and Aim: Enrofloxacin and tylosin can be combined into an antibiotic formulation which is expected to have a broader range of antibacterial activity against various infections in broilers. Validation method analysis of the levels of these two active compounds needs to be done for future use in pharmacokinetic or residual studies. The present study aims to determine a suitable validation method of isocratic high-performance liquid chromatography (HPLC) to measure the concentration of antibiotic combinations in the broiler liver, kidney, and muscles.
Materials and Methods: The combination of enrofloxacin and tylosin in the liver, kidney, and muscle was validated by HPLC method to find the procedures, processes, equipment, and systems used, consistently provides the appropriate results. The chromatography system consisted of an Octadecyl-silica column of 5 μm in diameter and 150 mm in length with a mobile phase of a mixture of 0.05 M monobasic sodium phosphate (pH 2.5) and acetonitrile (65:35 v/v). The solution was detected at a wavelength of 280 nm, 30°C, a flow rate of 1 mL/min, and an injection volume of 20 μL. The combination antibiotics powder was produced from PT Tekad Mandiri Citra, Bandung, Indonesia, and broiler tissues obtained from day-old chick broilers maintained for 30 days with free antibiotic feed.
Results: Validation of a combination solution of enrofloxacin and tylosin shows the linearity values of enrofloxacin and tylosin in the liver, kidney, and muscles as r2=0.9988, r2=0.9999, r2=0.9997, r2=0.9989, r2=0.9978, and r2=0.9962. The accuracy and precision values of enrofloxacin in the liver, kidney, and muscles were 5.53, 6.23, and 6.93, respectively. The values of accuracy and precision of tylosin in the liver, kidney, and muscles were 10.43, 4.63, and 7.16%, respectively. The retention times for enrofloxacin and tylosin were 1.945-2.000 min and 4.175-4.342 min. The limit of detection (LOD) and limit of quantity (LOQ) values for enrofloxacin were 3.03 and 10.1 μg/g, respectively. In contrast, the LOD and LOQ values for tylosin were 9.05 and 30.17 μg/g, respectively.
Conclusion: The value of linearity, accuracy, precision, specificity, and sensitivity of the combined solution of enrofloxacin and tylosin showed promising results.
Collapse
Affiliation(s)
- Agustina Dwi Wijayanti
- Department of Pharmacology, Faculty of Veterinary Medicine, Universitas Gadjah Mada, Jl. Fauna no. 2 Karangmalang, Yogyakarta, Indonesia
| | - Rahmad Dwi Ardiansyah
- Department of Pharmacology, Faculty of Veterinary Medicine, Universitas Gadjah Mada, Jl. Fauna no. 2 Karangmalang, Yogyakarta, Indonesia
| | - Anggi Muhtar Pratama
- Department of Pharmacology, Faculty of Veterinary Medicine, Universitas Gadjah Mada, Jl. Fauna no. 2 Karangmalang, Yogyakarta, Indonesia
| | - Aris Haryanto
- Department of Biochemistry, Faculty of Veterinary Medicine, Universitas Gadjah Mada, Jl. Fauna no. 2 Karangmalang, Yogyakarta, Indonesia
| | - Ida Fitriana
- Department of Pharmacology, Faculty of Veterinary Medicine, Universitas Gadjah Mada, Jl. Fauna no. 2 Karangmalang, Yogyakarta, Indonesia
| |
Collapse
|
2
|
Critical reagents for ligand-binding assays: process development methodologies to enable high-quality reagents. Bioanalysis 2022; 14:117-135. [PMID: 35019733 DOI: 10.4155/bio-2021-0217] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Development of biotherapeutics require pharmacokinetic/pharmacodynamic (PK/PD) and immunogenicity assays that are frequently in a ligand-binding assay (LBA) format. Conjugated critical reagents for LBAs are generated conjugation of the biotherapeutic drug or anti-drug molecule with a label. Since conjugated critical reagent quality impacts LBA performance, control of the generation process is essential. Our perspective is that process development methodologies should be integrated into critical reagent production to understand the impact of conjugation reactions, purification techniques and formulation conditions on the quality of the reagent. In this article, case studies highlight our approach to developing process conditions for different molecular classes of critical reagents including antibodies and a peptide. This development approach can be applied to the generation of future conjugated critical reagents.
Collapse
|
3
|
A normalized signal calibration with a long-term reference improves the robustness of RPLC-MRM/MS lipidomics in plasma. Anal Bioanal Chem 2021; 413:4077-4090. [PMID: 33907864 DOI: 10.1007/s00216-021-03364-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2021] [Accepted: 04/19/2021] [Indexed: 10/21/2022]
Abstract
Improving the reliability of quantification in lipidomic analyses is crucial for its successful application in the discovery of new biomarkers or in clinical practice. In this study, we propose a workflow to improve the accuracy and precision of lipidomic results issued by the laboratory. Lipid species from 11 classes were analyzed by a targeted RPLC-MRM/MS method. The peak areas of species were used to estimate concentrations by an internal standard calibration approach (IS-calibration) and by an alternative normalization signal calibration schema (NS-calibration). The latter uses a long-term reference plasma material as a matrix-matched external calibrator whose accuracy was compared to the NIST SRM-1950 mean consensus values reported by the Interlaboratory Lipidomics Comparison Exercise. The bias of lipid concentrations showed a good accuracy for 69 of 89 quantified lipids. The quantitation of species by the NS-calibration schema improved the within- and between-batch reproducibility in quality control samples, in comparison to the usual IS-calibration approach. Moreover, the NS-calibration workflow improved the robustness of the lipidomics measurements reducing the between-batch variability (relative standard deviation <10% for 95% of lipid species) in real conditions tested throughout the analysis of 120 plasma samples. In addition, we provide a free access web tool to obtain the concentration of lipid species by the two previously mentioned quantitative approaches, providing an easy follow-up of quality control tasks related to lipidomics.
Collapse
|