1
|
Manousi N, Kabir Α, Furton KG, Zacharis CK. Ionic-liquid/Carbowax 20 M functionalized capsule phase microextraction platform for the extraction of phosphodiesterase-5 inhibitors from human serum and urine prior to their determination by LC-MS. J Chromatogr A 2024; 1730:465157. [PMID: 39025028 DOI: 10.1016/j.chroma.2024.465157] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2024] [Revised: 07/06/2024] [Accepted: 07/09/2024] [Indexed: 07/20/2024]
Abstract
Capsule phase microextraction (CPME) is an efficient bioanalytical technique that streamlines the sample preparation by integrating the filtration and stirring mechanism directly into the device. A novel composite sorbent designed to be selective towards the target analytes consisting of mixed-mode sorbent chemistry synthesized by sol-gel technology is found promising and superior to the conventional C18 sorbents. Herein we describe the encapsulation of an ionic liquid (IL)/Carbowax 20M-functionalized sol-gel sorbent (sol-gel IL/Carbowax 20 M) in the lumen of porous polypropylene tubes for the capsule phase microextraction of three phosphodiesterase-5 inhibitors namely avanafil, sildenafil, and tadalafil in human serum and urine samples. The CPME device was characterized by Scanning Electron Microscopy (SEM) and Fourier-Transform Infrared Spectroscopy (FT-IR). The experimental parameters of CPME procedure (e.g. sample pH and ionic strength, extraction time, stirring rate, elution solvent and volume) were carefully optimized to achieve the highest possible extraction efficiency for the analytes. Method validation was conducted in terms of precision, linearity, accuracy, matrix effect, lower limits of quantification, and limits of detection (LOD). The method linearity was investigated in the range of 50-1000 ng mL-1 for all analytes while the precision was less than 11.8 % in all cases. For all analytes, the LOD values were 17 ng mL-1. The IL/CW 20M-functionalized microextraction capsules could be reused at least 25 times both for urine and serum samples. The green character and the applicability of the proposed method were evaluated using the ComplexGAPI and BAGI indexes. The optimized CPME protocol exhibited reduced consumption of organic solvent and generation of waste, cost-effectiveness, and simplicity. Finally, the proposed method was successfully applied to the analysis of sildenafil in human urine after administration of drug-containing formulation.
Collapse
Affiliation(s)
- Natalia Manousi
- Laboratory of Pharmaceutical Analysis, School of Pharmacy, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece
| | - Αbuzar Kabir
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, Miami, FL, USA.
| | - Kenneth G Furton
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, Miami, FL, USA
| | - Constantinos K Zacharis
- Laboratory of Pharmaceutical Analysis, School of Pharmacy, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece.
| |
Collapse
|
2
|
Samanidou V. Evaluating the "Blueness" of a method: the new drift to assess practicality in (green) bioanalysis. Bioanalysis 2024:1-4. [PMID: 39016191 DOI: 10.1080/17576180.2024.2374670] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2024] [Accepted: 06/27/2024] [Indexed: 07/18/2024] Open
Affiliation(s)
- Victoria Samanidou
- Laboratory of Analytical Chemistry, School of Chemistry, Aristotle University of Thessaloniki, Thessaloniki 54124, Greece
| |
Collapse
|
3
|
Pour PH, Suzaei FM, Daryanavard SM. Greenness assessment of microextraction techniques in therapeutic drug monitoring. Bioanalysis 2024; 16:249-278. [PMID: 38466891 PMCID: PMC11216521 DOI: 10.4155/bio-2023-0266] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Accepted: 02/08/2024] [Indexed: 03/13/2024] Open
Abstract
Aim: In this study, we evaluated the greenness and whiteness scores for microextraction techniques used in therapeutic drug monitoring. Additionally, the cons and pros of each evaluated method and their impacts on the provided scores are also discussed. Materials & methods: The Analytical Greenness Sample Preparation metric tool and white analytical chemistry principles are used for related published works (2007-2023). Results & conclusion: This study provided valuable insights for developing methods based on microextraction techniques with a balance in greenness and whiteness areas. Some methods based on a specific technique recorded higher scores, making them suitable candidates as green analytical approaches, and some others achieved high scores both in green and white areas with a satisfactory balance between principles.
Collapse
Affiliation(s)
- Parastoo Hosseini Pour
- Department of Chemistry, Faculty of Science, University of Hormozgan, Bandar-Abbas, 79177, Iran
| | - Foad Mashayekhi Suzaei
- Toxicology Laboratories, Monitoring the Human Hygiene Condition and Standard of Qeshm (MHCS Company), Qeshm Island, 79511, Iran
| | | |
Collapse
|
4
|
Ferracane A, Manousi N, Kabir A, Furton KG, Mondello A, Tranchida PQ, Zachariadis GA, Samanidou VF, Mondello L, Rosenberg E. Dual sorbent coating based magnet-integrated fabric phase sorptive extraction as a front-end to gas chromatography-mass spectrometry for multi-class pesticide determination in water samples. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 906:167353. [PMID: 37769739 DOI: 10.1016/j.scitotenv.2023.167353] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Revised: 09/23/2023] [Accepted: 09/23/2023] [Indexed: 10/03/2023]
Abstract
Magnet-integrated fabric phase sorptive extraction (MI-FPSE) is a sample preparation technique that has proved to be a powerful tool for environmental analysis. The fabrication and application of magnet-integrated dual sorbent-based FPSE membrane prepared by combining two different sol-gel sorbent-coated disks of different polarities together with a magnetic bar inserted between the two membranes to allow the stirring, was examined as novel preparation technique that not required samples pretreatments. The dual sorbent-based sample preparation platforms (made up of poly(tetrahydrofuran) and Carbowax 20M) were used for the extraction of seven classes of pesticides from ambient surface water samples prior to their determination by gas chromatography-mass spectrometry. Initially, different single and dual sol-gel sorbent-based MI-FPSE membranes were evaluated in terms of their extraction efficiency. The MI-FPSE with dual sol-gel sorbents were found to be superior to the single-materials MI-FPSE devices in terms of extraction recovery. The main parameters affecting the MI-FPSE extraction protocol (e.g., adsorption time, sample volume, stirring rate, salt addition, eluent type, desorption time and elution volume) were investigated. The selected extraction protocol enabled detection limits in the range between 0.001 and 0.16 ng mL-1. Furthermore, good relative standard deviation values for the intra-day and inter-day repeatability studies were obtained and were lower than 5.9 and 9.9 %, respectively. The proposed method was successfully used for the multi-class analysis of environmental surface water samples.
Collapse
Affiliation(s)
- Antonio Ferracane
- Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, Messina, Italy; Institute of Chemical Technologies and Analytics, Vienna University of Technology, 1060 Vienna, Austria
| | - Natalia Manousi
- Institute of Chemical Technologies and Analytics, Vienna University of Technology, 1060 Vienna, Austria; Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, Thessaloniki 54124, Greece
| | - Abuzar Kabir
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, Miami, FL, USA
| | - Kenneth G Furton
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, Miami, FL, USA
| | - Alice Mondello
- Department of Economics, University of Messina, Messina, Italy
| | - Peter Q Tranchida
- Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, Messina, Italy
| | - George A Zachariadis
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, Thessaloniki 54124, Greece
| | - Victoria F Samanidou
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, Thessaloniki 54124, Greece
| | - Luigi Mondello
- Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, Messina, Italy; Chromaleont s.r.l., c/o Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, Messina, Italy.
| | - Erwin Rosenberg
- Institute of Chemical Technologies and Analytics, Vienna University of Technology, 1060 Vienna, Austria
| |
Collapse
|
5
|
Manousi N, Tzanavaras PD, Zacharis CK. Microextraction based on liquid-solid phase transition of benzoic acid: Extraction of statins from human urine followed by chromatographic analysis. Talanta 2024; 266:125088. [PMID: 37625289 DOI: 10.1016/j.talanta.2023.125088] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Revised: 08/09/2023] [Accepted: 08/16/2023] [Indexed: 08/27/2023]
Abstract
Herein, a microextraction method was reported based on the liquid-solid phase transition of benzoic acid to quantify two statins, namely lovastatin and simvastatin in authentic human urine. The principle of the method is based on the phase transition of benzoic acid by altering the pH of the sample solution enabling efficient dispersion and phase separation in one step. Due to the moderate melting point of benzoic acid, its solidification is performed at ambient temperature without the need for sample cooling. Various experimental parameters that affect the performance of the analytes (i.e. extractant type and its concentration, acid type and concentration, and sample volume) have been examined and optimized. The method was validated based on the total error concept. For this purpose, accuracy profiles were constructed in the concentration range of 100-5000 ng mL-1 while β-expectation tolerance intervals fell within ±15% demonstrating that 95% of future results will not exceed the defined bias limits. The intra-day and inter-day method precision was less than 4.7% and 4.3% for both analytes, while the limit of detection was 15 ng mL-1 for both analytes. It was also proved that the usage of benzoic acid is advantageous in minimizing the potential inter-conversion of the analytes during the acidification step of the extraction procedure. The green potential of the proposed analytical scheme was examined based on Green Analytical Procedure index. The proposed sample pretreatment technique proved to be a valuable tool offering selectivity and rapidness. The developed method was used for the analysis of real human urine obtained after the administration of statin-based pharmaceutical formulations.
Collapse
Affiliation(s)
- Natalia Manousi
- Laboratory of Pharmaceutical Analysis, School of Pharmacy, Aristotle University of Thessaloniki, 54124, Thessaloniki, Greece
| | - Paraskevas D Tzanavaras
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, Thessaloniki, 54124, Greece
| | - Constantinos K Zacharis
- Laboratory of Pharmaceutical Analysis, School of Pharmacy, Aristotle University of Thessaloniki, 54124, Thessaloniki, Greece.
| |
Collapse
|
6
|
Manousi N, Ntorkou M, Tzanavaras PD, Zacharis CK. A review of bioanalytical applications of microextraction techniques combined with derivatization. Bioanalysis 2023; 15:937-954. [PMID: 37638635 DOI: 10.4155/bio-2023-0121] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/29/2023] Open
Abstract
Microextraction techniques have attracted the attention of many researchers working in the field of bioanalysis due to their unique advantages, mainly in downsizing the scale of sample preparation steps. In parallel, analytical derivatization offers a powerful combination in terms of additional sensitivity, selectivity and compatibility with modern separation techniques. The aim of this review is to discuss the most recent advances in bioanalytical sample preparation based on the combination of microextraction and analytical derivatization. Both innovative fundamental reports and analyte-targeted applications are included and discussed. Dispersive liquid-liquid extraction and solid-phase microextraction are the most common techniques that typically combined with derivatization, while the development of novel and greener protocols is receiving substantial consideration in the field of analytical chemistry.
Collapse
Affiliation(s)
- Natalia Manousi
- Laboratory of Pharmaceutical Analysis, School of Pharmacy, Aristotle University of Thessaloniki, Thessaloniki, GR-54124, Greece
| | - Marianna Ntorkou
- Laboratory of Pharmaceutical Analysis, School of Pharmacy, Aristotle University of Thessaloniki, Thessaloniki, GR-54124, Greece
| | - Paraskevas D Tzanavaras
- Laboratory of Analytical Chemistry, School of Chemistry, Faculty of Sciences, Aristotle University of Thessaloniki, GR-54124, Greece
| | - Constantinos K Zacharis
- Laboratory of Pharmaceutical Analysis, School of Pharmacy, Aristotle University of Thessaloniki, Thessaloniki, GR-54124, Greece
| |
Collapse
|
7
|
Manousi N, Ferracane A, Kalogiouri NP, Kabir A, Furton KG, Tranchida PQ, Zachariadis GA, Mondello L, Samanidou VF, Rosenberg E. Design and development of second-generation fabric phase sorptive extraction membranes: Proof-of-concept for the extraction of organophosphorus pesticides from apple juice prior to GC-MS analysis. Food Chem 2023; 424:136423. [PMID: 37247598 DOI: 10.1016/j.foodchem.2023.136423] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2023] [Revised: 05/02/2023] [Accepted: 05/17/2023] [Indexed: 05/31/2023]
Abstract
In this work, different sol-gel sorbent-coated second-generation fabric phase sorptive extraction (FPSE) membranes were synthesized using titania-based sol-gel precursors. The proposed membranes were tested for their efficiency to extract eleven selected organophosphorus pesticides (OPPs) from apple juice samples. Among the examined materials, sol-gel C18 coated titania-based FPSE membranes showed the highest extraction efficiency. These membranes were used for the optimization and validation of an FPSE method prior to analysis by gas chromatography-mass spectrometry. The detection limits for OPPs ranged between 0.03 and 0.08 ng mL-1. Moreover, the relative standard deviation was < 8.2% and 8.4% for intra-day and inter-day studies, respectively. The relative recoveries were 91-110% (intra-day study) and 90-106% (inter-day study) for all the target analytes, demonstrating good overall method accuracy. Moreover, the novel membranes were reusable at least 5 times. The titania-based membranes were compared to the conventional silica-based membranes and their utilization resulted in higher extraction recoveries.
Collapse
Affiliation(s)
- Natalia Manousi
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, Thessaloniki 54124, Greece; Laboratory of Pharmaceutical Analysis, School of Pharmacy, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece.
| | - Antonio Ferracane
- Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, Messina, Italy
| | - Natasa P Kalogiouri
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, Thessaloniki 54124, Greece
| | - Abuzar Kabir
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, Miami, FL, USA.
| | - Kenneth G Furton
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, Miami, FL, USA
| | - Peter Q Tranchida
- Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, Messina, Italy
| | - George A Zachariadis
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, Thessaloniki 54124, Greece
| | - Luigi Mondello
- Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, Messina, Italy; Chromaleont s.r.l., c/o Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, University of Messina, Messina, Italy
| | - Victoria F Samanidou
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, Thessaloniki 54124, Greece
| | - Erwin Rosenberg
- Institute of Chemical Technologies and Analytics, Vienna University of Technology, 1060 Vienna, Austria
| |
Collapse
|
8
|
Manousi N, Kabir A, Furton KG, Anthemidis A. Sol-Gel Graphene Oxide-Coated Fabric Disks as Sorbents for the Automatic Sequential-Injection Column Preconcentration for Toxic Metal Determination in Distilled Spirit Drinks. Molecules 2023; 28:molecules28052103. [PMID: 36903348 PMCID: PMC10004266 DOI: 10.3390/molecules28052103] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2023] [Revised: 02/16/2023] [Accepted: 02/21/2023] [Indexed: 03/02/2023] Open
Abstract
Sol-gel graphene oxide-coated polyester fabric platforms were synthesized and used for the on-line sequential injection fabric disk sorptive extraction (SI-FDSE) of toxic (i.e., Cd(II), Cu(II) and Pb(II)) metals in different distilled spirit drinks prior to their determination by electrothermal atomic absorption spectrometry (ETAAS). The main parameters that could potentially influence the extraction efficiency of the automatic on-line column preconcentration system were optimized and the SI-FDSE-ETAAS method was validated. Under optimum conditions, enhancement factors of 38, 120 and 85 were achieved for Cd(II), Cu(II) and Pb(II), respectively. Method precision (in terms of relative standard deviation) was lower than 2.9% for all analytes. The limits of detection for Cd(II), Cu(II) and Pb(II) were 1.9, 7.1 and 17.3 ng L-1, respectively. As a proof of concept, the proposed protocol was employed for the monitoring of Cd(II), Cu(II), and Pb(II) in distilled spirit drinks of different types.
Collapse
Affiliation(s)
- Natalia Manousi
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece
| | - Abuzar Kabir
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, Miami, FL 33131, USA
| | - Kenneth G. Furton
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, Miami, FL 33131, USA
| | - Aristidis Anthemidis
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, Miami, FL 33131, USA
- Correspondence:
| |
Collapse
|
9
|
Monolithic capsule phase microextraction prior to gas chromatography-mass spectrometry for the determination of organochlorine pesticides in environmental water samples. Microchem J 2022. [DOI: 10.1016/j.microc.2022.108355] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
10
|
Manousi N, Kabir A, Furton KG, Anthemidis AN. Dual Lab-in-Syringe Flow-Batch Platform for Automatic Fabric Disk Sorptive Extraction/Back-extraction as a Front End to Inductively Coupled Plasma Atomic Emission Spectrometry. Anal Chem 2022; 94:12943-12947. [PMID: 36098462 DOI: 10.1021/acs.analchem.2c02268] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
A novel dual lab-in-syringe flow-batch (D-LIS-FB) platform for automatic fabric-disk-in-syringe sorptive extraction followed by oxidative back-extraction as a front end to inductively coupled plasma atomic emission spectrometry (ICP-AES) is presented for the first time. Sol-gel poly(caprolactone)-poly(dimethylsiloxane)-poly(caprolactone)-coated polyester fabric disks were packed at the top of the glass barrel of a microsyringe pump as an alternative to column preconcentration. Herein lie multiple significant advantages including effectiveness, compactness, lower back-pressure, and lower time of analysis. Copper, lead, and cadmium were used as model analytes for the exploration of the capabilities of the developed platform. The online retained metal-diethyldithiophosphate complexes were eluted using diisopropyl ketone prior to atomization. Undesirable incompatibility of organic solvents for direct injection into the ICP-AES system was overcome ingeniously in a flow manner by oxidative back-extraction of the analytes utilizing a second lab-in-syringe setup. Following its optimization, the D-LIS-FB platform showed excellent linearity, in combination with good method precision (i.e., RSD < 3.4%) and trueness. Moreover, the limits of detection were 0.25 μg L-1 for Cd(II), 0.13 μg L-1 for Cu(II), and 0.37 μg L-1 for Pb(II), confirming the applicability of the proposed system for metal analysis at trace levels. As a proof-of-concept, the developed versatile system was utilized for the analysis of different environmental, food, and biological samples.
Collapse
Affiliation(s)
- Natalia Manousi
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, Thessaloniki 54124, Greece
| | - Abuzar Kabir
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, Miami, Florida 33131, United States
| | - Kenneth G Furton
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, Miami, Florida 33131, United States
| | - Aristidis N Anthemidis
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, Thessaloniki 54124, Greece
| |
Collapse
|
11
|
Sidiropoulou G, Kabir A, Furton KG, Kika FS, Fytianos K, Tzanavaras PD, Zacharis CK. Combination of fabric phase sorptive extraction with UHPLC-ESI-MS/MS for the determination of adamantine analogues in human urine. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107250] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
|
12
|
Ares-Fuentes AM, Lorenzo RA, Fernández P, Fernández AM, Furton KG, Kabir A, Carro AM. Determination of synthetic opioids in oral fluid samples using fabric phase sorptive extraction and gas chromatography-mass spectrometry. J Chromatogr A 2022; 1663:462768. [PMID: 34974368 DOI: 10.1016/j.chroma.2021.462768] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2021] [Revised: 12/15/2021] [Accepted: 12/20/2021] [Indexed: 01/10/2023]
Abstract
New psychoactive substances (NPS) continue to emerge in the drug market every year, becoming a global threat to public health and safety. These compounds are mostly synthetic cannabinoids and designer cathinones. However, synthetic opioids have appeared on the recreational drug markets in recent years, particularly fentanyl and its derivatives ("fentanyls"). Fentanyl and its analogs are related to harmful intoxications and an increase in opioid-related mortality in many countries, such as in the United States and Europe in the last years. Taking the drug related global crisis into consideration, this work developed and validated an effective and sensitive method based on fabric phase sorptive extraction (FPSE) followed by gas chromatography-mass spectrometry (GC-MS) for the simultaneous determination of 11 fentanyl analogs in oral fluid samples. The extraction was carried out using a sol-gel Carbowax 20 M sorbent immobilized on 100% cellulose fabric substrate and using ethyl acetate as the desorption solvent. The limits of detection (LODs) and quantification (LOQs) ranged from 1 to 15 ng mL-1 and 5 to 50 ng mL-1, respectively. Intra-day and inter-day precision were found within 8.2% and 8.6%, respectively, while accuracy ranged from -5.5 to 9.1%, in accordance with the established criteria. The absolute recovery values were in the range of 94.5%-109.1%. The validated method demonstrated its great potential to detect and quantify fentanyl analogs in possible forensic work and off-site analysis in road traffic cases.
Collapse
Affiliation(s)
- Ana M Ares-Fuentes
- Department of Analytical Chemistry, Nutrición y Bromatología, Faculty of Chemistry and Health Research, Institute of Santiago de Compostela (IDIS), University of Santiago de Compostela, Avda de las Ciencias S/N, Santiago de Compostela E-15782, Spain
| | - Rosa A Lorenzo
- Department of Analytical Chemistry, Nutrición y Bromatología, Faculty of Chemistry and Health Research, Institute of Santiago de Compostela (IDIS), University of Santiago de Compostela, Avda de las Ciencias S/N, Santiago de Compostela E-15782, Spain
| | - Purificación Fernández
- Institute of Legal Medicine, Forensic Toxicology Service, University of Santiago de Compostela, Santiago de Compostela E-15782, Spain
| | | | - Kenneth G Furton
- Department of Chemistry and Biochemistry, International Forensic Research Institute, Florida International University, Miami, FL 33199, USA
| | - Abuzar Kabir
- Department of Chemistry and Biochemistry, International Forensic Research Institute, Florida International University, Miami, FL 33199, USA; Department of Pharmacy, Faculty of Allied Health Sciences, Daffodil International University, Dhaka 1207, Bangladesh
| | - Antonia M Carro
- Department of Analytical Chemistry, Nutrición y Bromatología, Faculty of Chemistry and Health Research, Institute of Santiago de Compostela (IDIS), University of Santiago de Compostela, Avda de las Ciencias S/N, Santiago de Compostela E-15782, Spain; Department of Analytical Chemistry, Nutrición y Bromatología, Faculty of Chemistry. Health Research, Institute of Santiago de Compostela (IDIS). Instituto de Materiais (iMATUS). University of Santiago de Compostela, Avda de las Ciencias S/N, Santiago de Compostela E-15782, Spain.
| |
Collapse
|