1
|
Gopal N, Chauhan N, Jain U, Dass SK, Sharma HS, Chandra R. Advancement in biomarker based effective diagnosis of neonatal sepsis. ARTIFICIAL CELLS, NANOMEDICINE, AND BIOTECHNOLOGY 2023; 51:476-490. [PMID: 37656048 DOI: 10.1080/21691401.2023.2252016] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/06/2022] [Revised: 08/17/2023] [Accepted: 08/18/2023] [Indexed: 09/02/2023]
Abstract
Neonatal sepsis is considered as alarming medical emergency and becomes the common global reason of neonatal mortality. Non-specific symptoms and limitations of conventional diagnostic methods for neonatal sepsis mandate fast and reliable method to diagnose disease for point of care application. Recently, disease specific biomarkers have gained interest for rapid diagnosis that led to the development of electrochemical biosensor with enhanced specificity, sensitivity, cost-effectiveness and user-friendliness. Other than conventional biomarker C-reactive protein to diagnose neonatal sepsis, several potential biomarkers including Procalcitonin (PCT), Serum amyloid A (SAA) and other candidates are extensively investigated. The present review provides insights on advancements and diagnostic abilities of protein and nucleotide based biomarkers with their incorporation in developing electrochemical biosensors by employing novel fabrication strategies. This review provides an overview of most promising biomarker and its capability for neonatal sepsis diagnosis to fulfil future demand to develop electrochemical biosensor for point-of-care applications.
Collapse
Affiliation(s)
- Neha Gopal
- Department of Chemistry, University of Delhi, Delhi, India
| | - Nidhi Chauhan
- Amity Institute of Nanotechnology, Amity University, Noida, Uttar Pradesh, India
| | - Utkarsh Jain
- Amity Institute of Nanotechnology, Amity University, Noida, Uttar Pradesh, India
| | - Sujata K Dass
- Department of Neurology, BLK Super Speciality Hospital, New Delhi, India
| | - Hari S Sharma
- Department of Pathology and Clinical Bioinformatics, Erasmus MC, University Medical Center, Rotterdam, The Netherlands
| | - Ramesh Chandra
- Department of Chemistry, University of Delhi, Delhi, India
- Institute of Nanomedical Sciences (INMS), University of Delhi, Delhi, India
- Dr. B. R. Ambedkar Center for Biomedical Research, University of Delhi, Delhi, India
| |
Collapse
|
2
|
Aoki H, Miyazaki R, Ohama M, Murata M, Asai K, Ogata G, Einaga Y. Urine protein quantification in human urine on boron-doped diamond electrodes based on the electrochemical reaction of Coomassie brilliant blue. Analyst 2023; 148:4396-4405. [PMID: 37551933 DOI: 10.1039/d3an01000g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/09/2023]
Abstract
Urinalysis is attracting interest in personal healthcare management as part of a general move to improve quality of life. Urine contains various metabolites and the protein level in urine is an indicator of kidney function. In this study, a novel electrochemical sensing system based on boron-doped diamond (BDD) electrodes was developed for the detection of protein concentrations in human urine. BDD electrodes have the advantages of a wide electrochemical potential window and low non-specific adsorption, making them ideal for simple, rapid, and compact devices for home detection of bio-relevant substances. Coomassie brilliant blue (CBB), a dye that selectively and strongly binds to urine proteins, was found to be a redox-active indicator to show a decrease in its redox currents in relation to the concentration of protein in urine samples. Our detailed studies of BDD electrodes showed their limit of detection to be 2.57 μg mL-1 and that they have a linear response that ranges from 0 to 400 μg mL-1 in urine samples. We also investigated the detection of urine protein in different urine samples. Our results agreed with those obtained using conventional colorimetric analysis. We believe this to be the first study of electrochemical detection of urine protein in urine samples on BDD electrodes, which is of great significance to be able to obtain results with electrical signals rapidly compared to conventional colorimetric analysis. This CBB-BDD technique has the potential to assist healthcare management in the form of a rapid daily diagnostic test to judge whether a more detailed examination is needed.
Collapse
Affiliation(s)
- Hiroshi Aoki
- Environmental Management Research Institute, National Institute of Advance Industrial Science and Technology (AIST), 16-1 Onogawa, Tsukuba 305-8569, Japan.
- Department of Chemistry, Faculty of Science and Technology, Keio University, 3-14-1 Hiyoshi, Yokohama 223-8522, Japan.
| | - Risa Miyazaki
- Environmental Management Research Institute, National Institute of Advance Industrial Science and Technology (AIST), 16-1 Onogawa, Tsukuba 305-8569, Japan.
- Department of Chemistry, Faculty of Science and Technology, Keio University, 3-14-1 Hiyoshi, Yokohama 223-8522, Japan.
| | - Miho Ohama
- Environmental Management Research Institute, National Institute of Advance Industrial Science and Technology (AIST), 16-1 Onogawa, Tsukuba 305-8569, Japan.
- Department of Chemistry, Faculty of Science and Technology, Keio University, 3-14-1 Hiyoshi, Yokohama 223-8522, Japan.
| | - Michio Murata
- Department of Chemistry, Faculty of Science and Technology, Keio University, 3-14-1 Hiyoshi, Yokohama 223-8522, Japan.
| | - Kai Asai
- Department of Chemistry, Faculty of Science and Technology, Keio University, 3-14-1 Hiyoshi, Yokohama 223-8522, Japan.
- Department of Sensor Development, First Screening Co., Ltd., 1-30-14 Yoyogi, Shibuya 151-0053, Japan
| | - Genki Ogata
- Department of Chemistry, Faculty of Science and Technology, Keio University, 3-14-1 Hiyoshi, Yokohama 223-8522, Japan.
| | - Yasuaki Einaga
- Department of Chemistry, Faculty of Science and Technology, Keio University, 3-14-1 Hiyoshi, Yokohama 223-8522, Japan.
| |
Collapse
|
3
|
Ganguly A, Gunda V, Thai K, Prasad S. Inflammatory Stimuli Responsive Non-Faradaic, Ultrasensitive Combinatorial Electrochemical Urine Biosensor. SENSORS (BASEL, SWITZERLAND) 2022; 22:7757. [PMID: 36298107 PMCID: PMC9611881 DOI: 10.3390/s22207757] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/05/2022] [Revised: 09/28/2022] [Accepted: 10/01/2022] [Indexed: 06/16/2023]
Abstract
In this work, we propose a novel diagnostic biosensor that can enable stratification of disease states based on severity and hence allow for clear and actionable diagnoses. The scheme can potentially boost current Point-Of-Care (POC) biosensors for diseases that require time-critical stratification. Here, two key inflammatory biomarkers—Interleukin-8 and Interleukin-6—have been explored as proof of concept, and a four-class stratification of inflammatory disease severity is discussed. Our method is superior to traditional lab techniques as it is faster (<4 minutes turn-around time) and can work with any combination of disease biomarkers to categorize diseases by subtypes and severity. At its core, the biosensor relies on electrochemical impedance spectroscopy to transduce subtle inflammatory stimuli at the input for IL-8 and IL-6 for a limit of detection (LOD) of 1 pg/mL each. The biosensing scheme utilizes a two-stage random forest machine learning model for 4-state output disease classification with a 98.437% accuracy. This scheme can potentially boost the diagnostic power of current electrochemical biosensors for better precision therapy and improved patient outcomes.
Collapse
Affiliation(s)
| | | | | | - Shalini Prasad
- Department of Bioengineering, The University of Texas at Dallas, Richardson, TX 75080, USA
| |
Collapse
|
4
|
Pauliukaite R, Voitechovič E. Multisensor Systems and Arrays for Medical Applications Employing Naturally-Occurring Compounds and Materials. SENSORS (BASEL, SWITZERLAND) 2020; 20:E3551. [PMID: 32585936 PMCID: PMC7349305 DOI: 10.3390/s20123551] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/21/2020] [Revised: 06/17/2020] [Accepted: 06/20/2020] [Indexed: 12/14/2022]
Abstract
The significant improvement of quality of life achieved over the last decades has stimulated the development of new approaches in medicine to take into account the personal needs of each patient. Precision medicine, providing healthcare customization, opens new horizons in the diagnosis, treatment and prevention of numerous diseases. As a consequence, there is a growing demand for novel analytical devices and methods capable of addressing the challenges of precision medicine. For example, various types of sensors or their arrays are highly suitable for simultaneous monitoring of multiple analytes in complex biological media in order to obtain more information about the health status of a patient or to follow the treatment process. Besides, the development of sustainable sensors based on natural chemicals allows reducing their environmental impact. This review is concerned with the application of such analytical platforms in various areas of medicine: analysis of body fluids, wearable sensors, drug manufacturing and screening. The importance and role of naturally-occurring compounds in the development of electrochemical multisensor systems and arrays are discussed.
Collapse
Affiliation(s)
- Rasa Pauliukaite
- Department of Nanoengineering, Center for Physical Sciences and Technology, Savanoriu Ave. 231, LT-02300 Vilnius, Lithuania;
| | | |
Collapse
|
5
|
Sardesai AU, Dhamu VN, Paul A, Muthukumar S, Prasad S. Design and Electrochemical Characterization of Spiral Electrochemical Notification Coupled Electrode (SENCE) Platform for Biosensing Application. MICROMACHINES 2020; 11:E333. [PMID: 32213807 PMCID: PMC7143249 DOI: 10.3390/mi11030333] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/02/2020] [Revised: 03/22/2020] [Accepted: 03/23/2020] [Indexed: 01/08/2023]
Abstract
C-reactive protein (CRP) is considered to be an important biomarker associated with many diseases. During any physiological inflammation, the level of CRP reaches its peak at 48 h, whereas its half-life is around 19 h. Hence, the detection of low-level CRP is an important task for the prognostic management of diseases like cancer, stress, metabolic disorders, cardiovascular diseases, and so on. There are various techniques available in the market to detect low-level CRP like ELISA, Western blot, etc. An electrochemical biosensor is one of the important miniaturized platforms which provides sensitivity along with ease of operation. The most important element of an electrochemical biosensor platform is the electrode which, upon functionalization with a probe, captures the selective antibody-antigen interaction and produces a digital signal in the form of potential/current. Optimization of the electrode design can increase the sensitivity of the sensor by 5-10-fold. Herein, we come up with a new sensor design called the spiral electrochemical notification coupled electrode (SENCE) where the working electrode (WE) is concentric in nature, which shows better response than the market-available standard screen-printed electrode. The sensor is thoroughly characterized using a standard Ferro/Ferri couple. The sensing performance of the fabricated platform is also characterized by the detection of standard H2O2 using a diffusion-driven technique, and a low detection limit of 15 µM was achieved. Furthermore, we utilized the platform to detect a low level (100 ng/mL) of CRP in synthetic sweat. The manuscript provides emphasis on the design of a sensor that can offer good sensitivity in electrochemical biosensing applications.
Collapse
Affiliation(s)
- Abha Umesh Sardesai
- Department of Bioengineering, The University of Texas at Dallas, Richardson, TX 75080, USA
| | - Vikram Narayanan Dhamu
- Department of Bioengineering, The University of Texas at Dallas, Richardson, TX 75080, USA
| | - Anirban Paul
- Department of Bioengineering, The University of Texas at Dallas, Richardson, TX 75080, USA
| | - Sriram Muthukumar
- Department of Bioengineering, The University of Texas at Dallas, Richardson, TX 75080, USA
- EnLiSense LLC, 1813 Audubon Pondway, Allen, TX 75013, USA
| | - Shalini Prasad
- Department of Bioengineering, The University of Texas at Dallas, Richardson, TX 75080, USA
- EnLiSense LLC, 1813 Audubon Pondway, Allen, TX 75013, USA
| |
Collapse
|
6
|
Qureshi A, Niazi JH. Biosensors for detecting viral and bacterial infections using host biomarkers: a review. Analyst 2020; 145:7825-7848. [DOI: 10.1039/d0an00896f] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
A schematic diagram showing multiple modes of biosensing platforms for the diagnosis of bacterial or viral infections.
Collapse
Affiliation(s)
- Anjum Qureshi
- Sabanci University
- SUNUM Nanotechnology Research and Application Center
- Tuzla 34956
- Turkey
| | - Javed H. Niazi
- Sabanci University
- SUNUM Nanotechnology Research and Application Center
- Tuzla 34956
- Turkey
| |
Collapse
|
7
|
Lei R, Huo R, Mohan C. Current and emerging trends in point-of-care urinalysis tests. Expert Rev Mol Diagn 2020; 20:69-84. [PMID: 31795785 PMCID: PMC7365142 DOI: 10.1080/14737159.2020.1699063] [Citation(s) in RCA: 37] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2019] [Accepted: 11/26/2019] [Indexed: 02/06/2023]
Abstract
Introduction: The development of point-of-care testing (POCT) has made clinical diagnostics available, affordable, rapid, and easy to use since the 1990s.The significance of this platform rests on its potential to empower patients to monitor their own health status more frequently, in the convenience of their home, so that diseases can be diagnosed at the earliest possible time-point. Recent advances have expanded traditional formats such as qualitative or semi-quantitative dipsticks and lateral flow immunoassays to newer platforms such as microfluidics and paper-based assays where signals can be measured quantitatively using handheld devices.Areas covered: This review discusses: (1) working principles and operating mechanisms of both existing and emerging POCT platforms, (2) urine analytes measured using POCT in comparison to the laboratory or clinical 'gold standard,' and (3) limitations of existing POCT and expectations of emerging POCT in urinalysis.Expert opinion: Currently, a variety of biological samples such as urine, saliva, serum, plasma, and other fluids can be applied to POCT for quick diagnosis, especially in resource-limited settings. Emerging platforms will increasingly empower individuals to monitor their health status through frequent urine analysis even from their homes. The impact of these emerging technologies on healthcare is likely to be transformative.
Collapse
Affiliation(s)
- Rongwei Lei
- Department of Biomedical Engineering, University of Houston, Houston, TX
| | - Rannon Huo
- Department of Biomedical Engineering, University of Houston, Houston, TX
| | - Chandra Mohan
- Department of Biomedical Engineering, University of Houston, Houston, TX
| |
Collapse
|
8
|
Lin KC, Kinnamon D, Sankhala D, Muthukumar S, Prasad S. AWARE: A Wearable Awareness with Real-time Exposure, for monitoring alcohol consumption impact through ethyl glucuronide detection. Alcohol 2019; 81:93-99. [PMID: 30366035 DOI: 10.1016/j.alcohol.2018.10.006] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2018] [Revised: 09/14/2018] [Accepted: 10/17/2018] [Indexed: 12/31/2022]
Abstract
Here we demonstrate for the first time a dynamic monitoring of the ethanol metabolite ethyl glucuronide (EtG) for a more robust evaluation of alcohol consumption, compared to conventional methods. A wearable biosensor device capable of reporting EtG levels in sweat continuously via low power impedance spectroscopy is reported. The custom hardware was compared against a conventional benchtop potentiostat, and demonstrated comparable results in the application of EtG detection in low volume sweat. The device successfully differentiated three distinct EtG concentrations correlating to simulated drinking scenarios estimated to be 1, 2, and 3 standard U.S. drinks consumed over a duration of 60 min, with p < 0.0001. This device has the potential to enable moderate drinkers to engage in guided decision-making, based on objective data, to address the needs of alcohol-sensitive populations. The device also will serve as a tool for researchers to better understand and characterize the relationship between sweat EtG and consumed alcohol.
Collapse
Affiliation(s)
- Kai-Chun Lin
- Department of Bioengineering, University of Texas at Dallas, 800 West Campbell Rd., Richardson, TX 75080, United States
| | - David Kinnamon
- Department of Bioengineering, University of Texas at Dallas, 800 West Campbell Rd., Richardson, TX 75080, United States
| | - Devangsingh Sankhala
- Department of Bioengineering, University of Texas at Dallas, 800 West Campbell Rd., Richardson, TX 75080, United States
| | | | - Shalini Prasad
- Department of Bioengineering, University of Texas at Dallas, 800 West Campbell Rd., Richardson, TX 75080, United States.
| |
Collapse
|
9
|
Parthasarathy R, Monette CE, Bracero S, S Saha M. Methods for field measurement of antibiotic concentrations: limitations and outlook. FEMS Microbiol Ecol 2019; 94:5033401. [PMID: 29931290 DOI: 10.1093/femsec/fiy105] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2018] [Accepted: 06/04/2018] [Indexed: 11/13/2022] Open
Abstract
The growing prevalence of antibiotic resistance poses an increasingly serious threat to human health. Although an important driver of antibiotic resistance is the continuous exposure of bacteria to sublethal concentrations of antibiotics in natural environments, antibiotic pollutants are not currently tracked globally or systematically. This limits the international capacity to address the rise of antibiotic resistance at its source. To address this lack of data, the development of methods to measure antibiotic concentrations on-site is essential. These methods, ideally, must be sensitive to sublethal concentrations of antibiotics and require minimal technical expertise. Furthermore, factors such as cost, selectivity, biosafety and the ability to multiplex must be evaluated in the context of field use. Based on these criteria, we provide a critical review of current methods in antibiotic detection and evaluate their adaptability for use on-site. We categorize these methods into microbiological assays, physical and chemical assays, immunoassays, aptasensors and whole-cell biosensors. We recommend continued development of a dipstick or microfluidics approach with a bacterial promoter-based mechanism and colorimetric output. This technique would incorporate the advantageous aspects of existing methods, maximize shelf-life and ease-of-use, and require minimal resources to implement in the field.
Collapse
Affiliation(s)
- Ranjani Parthasarathy
- Department of Biology, Integrated Science Center, College of William and Mary, 540 Landrum Dr., Williamsburg, Virginia, 23187-8795, USA
| | - Callan E Monette
- Department of Biology, Integrated Science Center, College of William and Mary, 540 Landrum Dr., Williamsburg, Virginia, 23187-8795, USA
| | - Sabrina Bracero
- Department of Biology, Integrated Science Center, College of William and Mary, 540 Landrum Dr., Williamsburg, Virginia, 23187-8795, USA
| | - Margaret S Saha
- Department of Biology, Integrated Science Center, College of William and Mary, 540 Landrum Dr., Williamsburg, Virginia, 23187-8795, USA
| |
Collapse
|
10
|
Small AC, Thorogood SL, Shah O, Healy KA. Emerging Mobile Platforms to Aid in Stone Management. Urol Clin North Am 2019; 46:287-301. [PMID: 30961861 DOI: 10.1016/j.ucl.2018.12.010] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Nephrolithiasis is an increasingly common condition worldwide and mobile technology is revolutionizing how patients with kidney stone are being diagnosed and managed. Emerging platforms include software applications to increase adherence to stone prevention, mobile compatible hardware, online social media communities, and telemedicine. Applications and hardware specifically relevant to increasing hydration, diet modification, medication adherence, and rapid diagnosis (ie, mobile ultrasound and endoscopy) have the greatest potential to reduce stone recurrence and expedite treatment. Social media and online communities have also been rapidly adopted by patients and providers to promote education and support.
Collapse
Affiliation(s)
- Alexander C Small
- Department of Urology, Columbia University Medical Center, New York Presbyterian Hospital, 161 Fort Washington Avenue, 11th Floor, New York, NY 10032, USA
| | - Samantha L Thorogood
- Department of Urology, Columbia University Medical Center, New York Presbyterian Hospital, 161 Fort Washington Avenue, 11th Floor, New York, NY 10032, USA
| | - Ojas Shah
- Department of Urology, Columbia University Medical Center, New York Presbyterian Hospital, 161 Fort Washington Avenue, 11th Floor, New York, NY 10032, USA
| | - Kelly A Healy
- Department of Urology, Columbia University Medical Center, New York Presbyterian Hospital, 161 Fort Washington Avenue, 11th Floor, New York, NY 10032, USA.
| |
Collapse
|