1
|
Cahyanto A, Liemidia M, Karlina E, Zakaria MN, Shariff KA, Sukotjo C, El-Ghannam A. Bioactive Carbonate Apatite Cement with Enhanced Compressive Strength via Incorporation of Silica Calcium Phosphate Composites and Calcium Hydroxide. MATERIALS (BASEL, SWITZERLAND) 2023; 16:2071. [PMID: 36903186 PMCID: PMC10003863 DOI: 10.3390/ma16052071] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/01/2023] [Revised: 02/28/2023] [Accepted: 03/02/2023] [Indexed: 06/18/2023]
Abstract
Carbonate apatite (CO3Ap) is a bioceramic material with excellent properties for bone and dentin regeneration. To enhance its mechanical strength and bioactivity, silica calcium phosphate composites (Si-CaP) and calcium hydroxide (Ca(OH)2) were added to CO3Ap cement. The aim of this study was to investigate the effect of Si-CaP and Ca(OH)2 on the mechanical properties in terms of the compressive strength and biological characteristics of CO3Ap cement, specifically the formation of an apatite layer and the exchange of Ca, P, and Si elements. Five groups were prepared by mixing CO3Ap powder consisting of dicalcium phosphate anhydrous and vaterite powder added by varying ratios of Si-CaP and Ca(OH)2 and 0.2 mol/L Na2HPO4 as a liquid. All groups underwent compressive strength testing, and the group with the highest strength was evaluated for bioactivity by soaking it in simulated body fluid (SBF) for one, seven, 14, and 21 days. The group that added 3% Si-CaP and 7% Ca(OH)2 had the highest compressive strength among the groups. SEM analysis revealed the formation of needle-like apatite crystals from the first day of SBF soaking, and EDS analysis indicated an increase in Ca, P, and Si elements. XRD and FTIR analyses confirmed the presence of apatite. This combination of additives improved the compressive strength and showed the good bioactivity performance of CO3Ap cement, making it a potential biomaterial for bone and dental engineering applications.
Collapse
Affiliation(s)
- Arief Cahyanto
- Department of Dental Materials Science and Technology, Faculty of Dentistry, Padjadjaran University, Jl. Raya Bandung Sumedang KM 21, Jatinangor 45363, Indonesia
- Department of Restorative Dentistry, Faculty of Dentistry, University of Malaya, Kuala Lumpur 50603, Malaysia
- Biomaterials Technology Research Groups, Faculty of Dentistry, University of Malaya, Kuala Lumpur 50603, Malaysia
| | - Michella Liemidia
- Faculty of Dentistry, Padjajaran University, Jl. Raya Bandung Sumedang KM 21, Jatinangor 45363, Indonesia
| | - Elin Karlina
- Department of Dental Materials Science and Technology, Faculty of Dentistry, Padjadjaran University, Jl. Raya Bandung Sumedang KM 21, Jatinangor 45363, Indonesia
- Department of Restorative Dentistry, Faculty of Dentistry, University of Malaya, Kuala Lumpur 50603, Malaysia
| | - Myrna Nurlatifah Zakaria
- Department of Restorative Dentistry, Faculty of Dentistry, University of Malaya, Kuala Lumpur 50603, Malaysia
- Department of Endodontology and Operative Dentistry, Faculty of Dentistry, Universitas Jenderal Achmad Yani, Jl. Terusan Jenderal Sudirman, Cimahi 40531, Indonesia
| | - Khairul Anuar Shariff
- School of Materials and Mineral Resources Engineering, Engineering Campus, Universiti Sains Malaysia, Nibong Tebal, Pulau Pinang 14300, Malaysia
| | - Cortino Sukotjo
- Department of Restorative Dentistry, University of Illinois at Chicago, Chicago, IL 60612, USA
| | - Ahmed El-Ghannam
- Department of Mechanical Engineering and Engineering Science, University of North Carolina at Charlotte, Charlotte, NC 28223, USA
| |
Collapse
|
2
|
Osteogenic Induction with Silicon Hydroxyapatite Using Modified Autologous Adipose Tissue-Derived Stromal Vascular Fraction: In Vitro and Qualitative Histomorphometric Analysis. MATERIALS 2022; 15:ma15051826. [PMID: 35269057 PMCID: PMC8911855 DOI: 10.3390/ma15051826] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/13/2022] [Revised: 02/24/2022] [Accepted: 02/25/2022] [Indexed: 12/16/2022]
Abstract
Large bone defects requiring invasive surgical procedures have long been a problem for orthopedic surgeons. Despite the use of autologous bone grafting, satisfactory results are often not achieved due to associated limitations. Biomaterials are viable alternatives and have lately been used in association with Stromal Vascular Fraction (SVF), stem cells, and signaling factors for bone tissue engineering (BTE). The objective of the current study was to assess the biocompatibility of Silicon Hydroxyapatite (Si-HA) and to improve osteogenic potential by using autologous adipose-derived SVF with Si-HA in a rabbit bone defect model. Si-HA granules synthesized using a wet precipitation method were used. They were characterized using scanning electron microscopy (SEM), Fourier transform infrared (FTIR), and X-ray diffraction (XRD). A hemolysis assay was used to assess the hemolytic effects of Si-HA, while cell viability was assessed through Alamar Blue assay using MC3T3 mouse osteoblasts. The osteogenic potential of Si-HA both alone and with enzymatically/non-enzymatically-derived SVF (modified) was performed by implantation in a rabbit tibia model followed by histomorphometric analysis and SEM of dissected bone after six weeks. The results showed that Si-HA granules were microporous and phase pure and that the addition of Silicon did not influence Si-HA phase composition. Si-HA granules were found to be non-hemolytic on the hemolysis assay and non-toxic to MC3T3 mouse osteoblasts on the Alamar Blue assay. Six weeks following implantation Si-HA showed high biocompatibility, with increased bone formation in all groups compared to control. Histologically more mature bone was formed in the Si-HA implanted along with non-enzymatically-derived modified SVF. Bone formation was observed on and around Si-HA, reflecting osseointegration. In conclusion, Si-HA is osteoconductive and promotes osteogenesis, and its use with SVF enhances osteogenesis.
Collapse
|
3
|
Ngo HX, Bai Y, Sha J, Ishizuka S, Toda E, Osako R, Kato A, Morioka R, Ramanathan M, Tatsumi H, Okui T, Kanno T. A Narrative Review of u-HA/PLLA, a Bioactive Resorbable Reconstruction Material: Applications in Oral and Maxillofacial Surgery. MATERIALS 2021; 15:ma15010150. [PMID: 35009297 PMCID: PMC8746248 DOI: 10.3390/ma15010150] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/19/2021] [Revised: 12/17/2021] [Accepted: 12/22/2021] [Indexed: 12/13/2022]
Abstract
The advent of bioresorbable materials to overcome limitations and replace traditional bone-reconstruction titanium-plate systems for bone fixation, thus achieving greater efficiency and safety in medical and dental applications, has ushered in a new era in biomaterial development. Because of its bioactive osteoconductive ability and biocompatibility, the forged composite of uncalcined/unsintered hydroxyapatite and poly L-lactic acid (u-HA/PLLA) has attracted considerable interest from researchers in bone tissue engineering, as well as from clinicians, particularly for applications in maxillofacial reconstructive surgery. Thus, various in vitro studies, in vivo studies, and clinical trials have been conducted to investigate the feasibility and weaknesses of this biomaterial in oral and maxillofacial surgery. Various technical improvements have been proposed to optimize its advantages and limit its disadvantages. This narrative review presents an up-to-date, comprehensive review of u-HA/PLLA, a bioactive osteoconductive and bioresorbable bone-reconstruction and -fixation material, in the context of oral and maxillofacial surgery, notably maxillofacial trauma, orthognathic surgery, and maxillofacial reconstruction. It simultaneously introduces new trends in the development of bioresorbable materials that could used in this field. Various studies have shown the superiority of u-HA/PLLA, a third-generation bioresorbable biomaterial with high mechanical strength, biocompatibility, and bioactive osteoconductivity, compared to other bioresorbable materials. Future developments may focus on controlling its bioactivity and biodegradation rate and enhancing its mechanical strength.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | | | | | | | | | - Takahiro Kanno
- Correspondence: ; Tel.: +81-(0)853-20-2301; Fax: +81-(0)853-20-2299
| |
Collapse
|
4
|
Boyle R, Varelas J. Otoconia Structure After Short- and Long-Duration Exposure to Altered Gravity. J Assoc Res Otolaryngol 2021; 22:509-525. [PMID: 34008038 PMCID: PMC8476704 DOI: 10.1007/s10162-021-00791-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2020] [Accepted: 02/09/2021] [Indexed: 10/21/2022] Open
Abstract
Vertebrates use weight-lending otoconia in the inner ear otolith organs to enable detection of their translation during self or imposed movements and a change in their orientation with respect to gravity. In spaceflight, otoconia are near weightless. It has been hypothesized that otoconia undergo structural remodeling after exposure to weightlessness to restore normal sensation. A structural remodeling is reasoned to occur for hypergravity but in the opposite sense. We explored these hypotheses in several strains of mice within a Biospecimen Sharing Program in separate space- and ground-based projects. Mice were housed 90 days on the International Space Station, 13 days on two Shuttle Orbiter missions, or exposed to 90 days of hindlimb unloading or net 2.38 g via centrifugation. Corresponding flight habitat and standard cage vivarium controls were used. Utricular otoliths were visually analyzed using scanning electron microscopy and in selected samples before and after focused ion beam (FIB) milling. Results suggest a possible mass addition to the otoconia outer shell might occur after exposure to longer-duration spaceflight, but not short ones or hindlimb unloading. A destructive process is clearly seen after centrifugation: an ablation or thinning of the outer shell and cavitation of the inner core. This study provides a purely descriptive account of otoconia remodeling after exposures to altered gravity. The mechanism(s) underlying these processes must be identified and quantitatively validated to develop countermeasures to altered gravity levels during exploration missions.
Collapse
Affiliation(s)
- Richard Boyle
- National Aeronautics and Space Administration, Ames Research Center, Moffett Field, CA, 94035, USA.
| | - Joseph Varelas
- National Aeronautics and Space Administration, Ames Research Center, Moffett Field, CA, 94035, USA
- Science & Technology Innovation Labs, Universities Space Research Association, Ames Research Center, Moffett Field, CA, 94035, USA
| |
Collapse
|
5
|
Shah FA, Thomsen P, Palmquist A. Osseointegration and current interpretations of the bone-implant interface. Acta Biomater 2019; 84:1-15. [PMID: 30445157 DOI: 10.1016/j.actbio.2018.11.018] [Citation(s) in RCA: 151] [Impact Index Per Article: 30.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2018] [Revised: 10/28/2018] [Accepted: 11/12/2018] [Indexed: 02/07/2023]
Abstract
Complex physical and chemical interactions take place in the interface between the implant surface and bone. Various descriptions of the ultrastructural arrangement to various implant design features, ranging from solid and macroporous geometries to surface modifications on the micron-, submicron-, and nano- levels, have been put forward. Here, the current knowledge regarding structural organisation of the bone-implant interface is reviewed with a focus on solid devices, mainly metal (or alloy) intended for permanent anchorage in bone. Certain biomaterials that undergo surface and bulk degradation are also considered. The bone-implant interface is a heterogeneous zone consisting of mineralised, partially mineralised, and unmineralised areas. Within the meso-micro-nano-continuum, mineralised collagen fibrils form the structural basis of the bone-implant interface, in addition to accumulation of non-collagenous macromolecules such as osteopontin, bone sialoprotein, and osteocalcin. In the published literature, as many as eight distinct arrangements of the bone-implant interface ultrastructure have been described. The interpretation is influenced by the in vivo model and species-specific characteristics, healing time point(s), physico-chemical properties of the implant surface, implant geometry, sample preparation route(s) and associated artefacts, analytical technique(s) and their limitations, and non-compromised vs compromised local tissue conditions. The understanding of the ultrastructure of the interface under experimental conditions is rapidly evolving due to the introduction of novel techniques for sample preparation and analysis. Nevertheless, the current understanding of the interface zone in humans in relation to clinical implant performance is still hampered by the shortcomings of clinical methods for resolving the finer details of the bone-implant interface. STATEMENT OF SIGNIFICANCE: Being a hierarchical material by design, the overall strength of bone is governed by composition and structure. Understanding the structure of the bone-implant interface is essential in the development of novel bone repair materials and strategies, and their long-term success. Here, the current knowledge regarding the eventual structural organisation of the bone-implant interface is reviewed, with a focus on solid devices intended for permanent anchorage in bone, and certain biomaterials that undergo surface and bulk degradation. The bone-implant interface is a heterogeneous zone consisting of mineralised, partially mineralised, and unmineralised areas. Within the meso-micro-nano-continuum, mineralised collagen fibrils form the structural basis of the bone-implant interface, in addition to accumulation of non-collagenous macromolecules such as osteopontin, bone sialoprotein, and osteocalcin.
Collapse
|
6
|
Rydén L, Omar O, Johansson A, Jimbo R, Palmquist A, Thomsen P. Inflammatory cell response to ultra-thin amorphous and crystalline hydroxyapatite surfaces. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2017; 28:9. [PMID: 27896599 PMCID: PMC5126180 DOI: 10.1007/s10856-016-5814-2] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/22/2016] [Accepted: 11/08/2016] [Indexed: 05/04/2023]
Abstract
It has been suggested that surface modification with a thin hydroxyapatite (HA) coating enhances the osseointegration of titanium implants. However, there is insufficient information about the biological processes involved in the HA-induced response. This study aimed to investigate the inflammatory cell response to titanium implants with either amorphous or crystalline thin HA. Human mononuclear cells were cultured on titanium discs with a machined surface or with a thin, 0.1 μm, amorphous or crystalline HA coating. Cells were cultured for 24 and 96 h, with and without lipopolysaccharide (LPS) stimulation. The surfaces were characterized with respect to chemistry, phase composition, wettability and topography. Biological analyses included the percentage of implant-adherent cells and the secretion of pro-inflammatory cytokine (TNF-α) and growth factors (BMP-2 and TGF-β1). Crystalline HA revealed a smooth surface, whereas the amorphous HA displayed a porous structure, at nano-scale, and a hydrophobic surface. Higher TNF-α secretion and a higher ratio of adherent cells were demonstrated for the amorphous HA compared with the crystalline HA. TGF-β1 secretion was detected in all groups, but without any difference. No BMP-2 secretion was detected in any of the groups. The addition of LPS resulted in a significant increase in TNF-α in all groups, whereas TGF-β1 was not affected. Taken together, the results show that thin HA coatings with similar micro-roughness but a different phase composition, nano-scale roughness and wettability are associated with different monocyte responses. In the absence of strong inflammatory stimuli, crystalline hydroxyapatite elicits a lower inflammatory response compared with amorphous hydroxyapatite.
Collapse
Affiliation(s)
- Louise Rydén
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Box 412, Gothenburg, SE-405 30, Sweden
| | - Omar Omar
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Box 412, Gothenburg, SE-405 30, Sweden.
- BIOMATCELL, VINN Excellence Center of Biomaterials and Cell Therapy, Gothenburg, Sweden.
| | - Anna Johansson
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Box 412, Gothenburg, SE-405 30, Sweden
- BIOMATCELL, VINN Excellence Center of Biomaterials and Cell Therapy, Gothenburg, Sweden
| | - Ryo Jimbo
- Department of Oral and Maxillofacial Surgery and Oral Medicine, Faculty of Odontology, Malmö University, Malmö, Sweden
| | - Anders Palmquist
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Box 412, Gothenburg, SE-405 30, Sweden
- BIOMATCELL, VINN Excellence Center of Biomaterials and Cell Therapy, Gothenburg, Sweden
| | - Peter Thomsen
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Box 412, Gothenburg, SE-405 30, Sweden
- BIOMATCELL, VINN Excellence Center of Biomaterials and Cell Therapy, Gothenburg, Sweden
| |
Collapse
|