1
|
Iglesias JF, Roffi M, Losdat S, Muller O, Degrauwe S, Kurz DJ, Haegeli L, Weilenmann D, Kaiser C, Tapponnier M, Cook S, Cuculi F, Heg D, Windecker S, Pilgrim T. Long-term outcomes with biodegradable polymer sirolimus-eluting stents versus durable polymer everolimus-eluting stents in ST-segment elevation myocardial infarction: 5-year follow-up of the BIOSTEMI randomised superiority trial. Lancet 2023; 402:1979-1990. [PMID: 37898137 DOI: 10.1016/s0140-6736(23)02197-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/11/2023] [Revised: 09/26/2023] [Accepted: 09/28/2023] [Indexed: 10/30/2023]
Abstract
BACKGROUND Biodegradable polymer sirolimus-eluting stents improve early stent-related clinical outcomes compared to durable polymer everolimus-eluting stents in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention. The long-term advantages of biodegradable polymer sirolimus-eluting stents after complete degradation of its polymer coating in patients with STEMI remains however uncertain. METHODS BIOSTEMI Extended Survival (BIOSTEMI ES) was an investigator-initiated, follow-up extension study of the BIOSTEMI prospective, multicentre, single-blind, randomised superiority trial that compared biodegradable polymer sirolimus-eluting stents with durable polymer everolimus-eluting stents in patients with STEMI undergoing primary percutaneous coronary intervention at ten hospitals in Switzerland. All individuals who had provided written informed consent for participation in the BIOSTEMI trial were eligible for this follow-up study. The primary endpoint was target lesion failure, defined as a composite of cardiac death, target vessel myocardial re-infarction, or clinically indicated target lesion revascularisation, at 5 years. Superiority of biodegradable polymer sirolimus-eluting stents over durable polymer everolimus-eluting stents was declared if the Bayesian posterior probability for a rate ratio (RR) of less than 1 was greater than 0·975. Analyses were performed according to the intention-to-treat principle. The study was registered with ClinicalTrials.gov, NCT05484310. FINDINGS Between April 26, 2016, and March 9, 2018, 1300 patients with STEMI (1622 lesions) were randomly allocated in a 1:1 ratio to treatment with biodegradable polymer sirolimus-eluting stents (649 patients, 816 lesions) or durable polymer everolimus-eluting stents (651 patients, 806 lesions). At 5 years, the primary composite endpoint of target lesion failure occurred in 50 (8%) patients treated with biodegradable polymer sirolimus-eluting stents and in 72 (11%) patients treated with durable polymer everolimus-eluting stents (difference of -3%; RR 0·70, 95% Bayesian credible interval 0·51-0·95; Bayesian posterior probability for superiority 0·988). INTERPRETATION In patients undergoing primary percutaneous coronary intervention for STEMI, biodegradable polymer sirolimus-eluting stents were superior to durable polymer everolimus-eluting stents with respect to target lesion failure at 5 years of follow-up. The difference was driven by a numerically lower risk for ischaemia-driven target lesion revascularisation. FUNDING Biotronik.
Collapse
Affiliation(s)
- Juan F Iglesias
- Department of Cardiology, Geneva University Hospitals, Geneva, Switzerland.
| | - Marco Roffi
- Department of Cardiology, Geneva University Hospitals, Geneva, Switzerland
| | - Sylvain Losdat
- Clinical Trials Unit Bern, University of Bern, Bern, Switzerland
| | - Olivier Muller
- Department of Cardiology, Lausanne University Hospital, Lausanne, Switzerland
| | - Sophie Degrauwe
- Department of Cardiology, Geneva University Hospitals, Geneva, Switzerland
| | - David J Kurz
- Department of Cardiology, Triemlispital, Zurich, Switzerland
| | | | | | - Christoph Kaiser
- Department of Cardiology, Basel University Hospital, Basel, Switzerland
| | | | - Stéphane Cook
- Department of Cardiology, Hôpital Cantonal, Fribourg, Switzerland
| | - Florim Cuculi
- Department of Cardiology, Kantonsspital, Lucerne, Switzerland
| | - Dik Heg
- Clinical Trials Unit Bern, University of Bern, Bern, Switzerland
| | - Stephan Windecker
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Thomas Pilgrim
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| |
Collapse
|
2
|
Häner JD, Rohla M, Losdat S, Iglesias JF, Muller O, Eeckhout E, Kurz D, Weilenmann D, Kaiser C, Tapponnier M, Roffi M, Heg D, Windecker S, Pilgrim T. Ultrathin-strut vs thin-strut drug-eluting stents for multi and single-stent lesions: A lesion-level subgroup analysis of 2 randomized trials. Am Heart J 2023; 263:73-84. [PMID: 37192697 DOI: 10.1016/j.ahj.2023.05.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Revised: 05/04/2023] [Accepted: 05/04/2023] [Indexed: 05/18/2023]
Abstract
BACKGROUND Whether ultrathin-strut stents are particularly beneficial for lesions requiring implantation of more than 1 stent is unknown. METHODS In a post-hoc lesion-level analysis of 2 randomized trials comparing ultrathin-strut biodegradable polymer Sirolimus-eluting stents (BP-SES) vs thin-strut durable polymer Everolimus-eluting stents (DP-EES), lesions were stratified into multistent lesions (MSL) vs single-stent lesions (SSL). The primary endpoint was target lesion failure (TLF), a composite of lesion-related unclear/cardiac death, myocardial infarction (MI), or revascularization, at 24 months. RESULTS Among 5328 lesions in 3397 patients, 1492 (28%) were MSL (722 with BP-SES, 770 with DP-EES). At 2 years, TLF occurred in 63 lesions (8.9%) treated with BP-SES and 60 lesions (7.9%) treated with DP-EES in the MSL-group (subdistibution hazard ratio [SHR], 1.13; 95% CI, 0.77-1.64; P = .53), and in 121 (6.4%) and 136 (7.4%) lesions treated with BP-SES and DP-EES respectively (SHR, 0.86; 95% CI, 0.62-1.18; P = .35) in the SSL-group (P for interaction = .241). While the rates of lesion-related MI or revascularization were significantly lower in SSL treated with BP-SES as compared to DP-EES (3.5% vs 5.2%; SHR, 0.67; 95% CI 0.46-0.97; P = .036), no significant difference was observed in MSL (7.1% vs 5.4%; SHR, 1.31; 95% CI 0.85-2.03; P = .216) with significant interaction between groups (P for interaction = .014). CONCLUSIONS Rates of TLF are similar between ultrathin-strut BP-SES and thin-strut DP-EES in MSL and SSL. The use of ultrathin-strut BP-SES vs thin-strut DP-EES did not prove to be particularly beneficial for the treatment of multistent lesions. TRIAL REGISTRATION Post-hoc analysis from the BIOSCIENCE (NCT01443104) and BIOSTEMI (NCT02579031) trials.
Collapse
Affiliation(s)
- Jonas D Häner
- Department of Cardiology, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Miklos Rohla
- Department of Cardiology, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Sylvain Losdat
- Institute of Social and Preventive Medicine and Clinical Trials Unit, University of Bern, Bern, Switzerland
| | - Juan F Iglesias
- Department of Cardiology, Geneva University Hospitals, Geneva, Switzerland
| | - Olivier Muller
- Department of Cardiology, Lausanne University Hospital, Lausanne, Switzerland
| | - Eric Eeckhout
- Department of Cardiology, Lausanne University Hospital, Lausanne, Switzerland
| | - David Kurz
- Department of Cardiology, Triemli Hospital, Zurich, Switzerland
| | | | - Christoph Kaiser
- Department of Cardiology, Basel University Hospital, Basel; Switzerland
| | | | - Marco Roffi
- Department of Cardiology, Geneva University Hospitals, Geneva, Switzerland
| | - Dik Heg
- Institute of Social and Preventive Medicine and Clinical Trials Unit, University of Bern, Bern, Switzerland
| | - Stephan Windecker
- Department of Cardiology, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Thomas Pilgrim
- Department of Cardiology, Bern University Hospital, University of Bern, Bern, Switzerland.
| |
Collapse
|
3
|
Iglesias JF, Muller O, Losdat S, Roffi M, Kurz DJ, Weilenmann D, Kaiser C, Heg D, Windecker S, Pilgrim T. Complex primary percutaneous coronary intervention with ultrathin-strut biodegradable versus thin-strut durable polymer drug-eluting stents in patients with ST-segment elevation myocardial infarction: A subgroup analysis from the BIOSTEMI randomized trial. Catheter Cardiovasc Interv 2023; 101:687-700. [PMID: 36807456 DOI: 10.1002/ccd.30600] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/27/2022] [Revised: 01/22/2023] [Accepted: 02/08/2023] [Indexed: 02/21/2023]
Abstract
BACKGROUND Ultrathin-strut biodegradable polymer sirolimus-eluting stents (BP-SES) are superior to thin-strut durable polymer everolimus-eluting stents (DP-EES) with respect to target lesion failure (TLF) at 2 years among patients with ST-segment elevation myocardial infarction (STEMI). We sought to determine the impact of primary percutaneous coronary intervention (pPCI) complexity on long-term clinical outcomes with BP-SES versus DP-EES in STEMI patients. METHODS We performed a post hoc subgroup analysis from the BIOSTEMI (NCT02579031) randomized trial, which included individual data from 407 STEMI patients enrolled in the BIOSCIENCE trial (NCT01443104). STEMI patients were randomly assigned to treatment with ultrathin-strut BP-SES or thin-strut DP-EES, and further categorized into those undergoing complex versus noncomplex pPCI. Complex pPCI was defined by the presence of ≥1 of the following criteria: 3 vessel treatment, ≥3 stents implanted, ≥3 lesions treated, bifurcation lesion with ≥2 stents implanted, total stent length ≥60 mm, and/or chronic total occlusion treatment. The primary endpoint was TLF, a composite of cardiac death, target-vessel myocardial reinfarction, or clinically indicated target lesion revascularization, within 2 years. RESULTS Among a total of 1707 STEMI patients, 421 (24.7%) underwent complex pPCI. Baseline characteristics were similar between groups. At 2 years, TLF occurred in 14 patients (7.1%) treated with BP-SES and 25 patients (11.6%) treated with DP-EES (hazard ratio [HR]: 0.62; 95% confidence interval [CI]: 0.32-1.19; p = 0.15) in the complex pPCI group, and in 28 patients (4.4%) treated with BP-SES and 49 patients (8.2%) treated with DP-EES (HR: 0.54; 95% CI: 0.34-0.86; p = 0.008; p for interaction = 0.74) in the noncomplex pPCI group. Individual TLF components and stent thrombosis rates did not significantly differ between groups. CONCLUSION In a post hoc subgroup analysis from the BIOSTEMI randomized trial, ultrathin-strut BP-SES were superior to thin-strut DP-EES with respect to TLF at 2 years among STEMI patients undergoing both complex and noncomplex pPCI.
Collapse
Affiliation(s)
- Juan F Iglesias
- Department of Cardiology, Geneva University Hospitals, Geneva, Switzerland
| | - Olivier Muller
- Department of Cardiology, Lausanne University Hospital, Lausanne, Switzerland
| | | | - Marco Roffi
- Department of Cardiology, Geneva University Hospitals, Geneva, Switzerland
| | - David J Kurz
- Department of Cardiology, Triemlispital, Zurich, Switzerland
| | | | - Christoph Kaiser
- Department of Cardiology, Basel University Hospital, Basel, Switzerland
| | - Dik Heg
- CTU Bern, University of Bern, Bern, Switzerland
| | - Stephan Windecker
- Department of Cardiology, Bern University Hospital, Bern, Switzerland
| | - Thomas Pilgrim
- Department of Cardiology, Bern University Hospital, Bern, Switzerland
| |
Collapse
|
4
|
Pilgrim T, Muller O, Heg D, Roffi M, Kurz DJ, Moarof I, Weilenmann D, Kaiser C, Tapponnier M, Losdat S, Eeckhout E, Valgimigli M, Jüni P, Windecker S, Iglesias JF. Biodegradable- Versus Durable-Polymer Drug-Eluting Stents for STEMI: Final 2-Year Outcomes of the BIOSTEMI Trial. JACC Cardiovasc Interv 2021; 14:639-648. [PMID: 33727005 DOI: 10.1016/j.jcin.2020.12.011] [Citation(s) in RCA: 32] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/28/2020] [Revised: 12/03/2020] [Accepted: 12/07/2020] [Indexed: 12/19/2022]
Abstract
OBJECTIVES The aim of this study was to investigate the safety and efficacy of biodegradable-polymer sirolimus-eluting stents (BP-SES) compared with durable-polymer everolimus-eluting stents (DP-EES) in patients with ST-segment elevation myocardial infarction (STEMI). BACKGROUND Primary percutaneous coronary intervention (PCI) is an effective treatment for patients with STEMI, and long-term outcomes are determined by the safety and efficacy profile of the newest generation drug-eluting stents. METHODS BIOSTEMI (A Comparison of an Ultrathin Strut Biodegradable Polymer Sirolimus-Eluting Stent With a Durable Polymer Everolimus-Eluting Stent for Patients With Acute ST-Segment Elevation Myocardial Infarction Undergoing Primary Percutaneous Coronary Intervention) was an investigator-initiated, multicenter, assessor-blind, randomized superiority trial using Bayesian methods. Patients with STEMI undergoing primary PCI within 24 h of symptom onset were randomized in a 1:1 ratio to receive BP-SES (n = 649) or DP-EES (n = 651). The primary endpoint was target lesion failure (TLF), a composite of cardiac death, target vessel myocardial reinfarction, and clinically indicated target lesion revascularization (TLR) at 2 years. RESULTS Between April 2016 and March 2018, 1,300 patients were included. Baseline characteristics were comparable between the 2 treatment groups. Follow-up through 2 years was complete in 1,221 patients (94%). At 2 years, TLF occurred in 33 patients (5.1%) treated with BP-SES and in 53 patients (8.1%) treated with DP-EES (rate ratio: 0.58; 95% Bayesian credible interval: 0.40 to 0.84; posterior probability of superiority = 0.998). The difference was driven by a lower incidence of clinically indicated TLR in patients treated with BP-SES compared with DP-EES (2.5% vs. 5.1%; rate ratio: 0.52; 95% Bayesian credible interval: 0.30 to 0.87; posterior probability of superiority = 0.993). There were no significant differences in rates of cardiac death, target vessel myocardial reinfarction, and definite stent thrombosis between the 2 treatment arms. CONCLUSIONS In patients with STEMI undergoing primary PCI, BP-SES were superior to DP-EES with respect to TLF at 2 years. The difference was driven by lower rates of ischemia-driven TLR. (A Comparison of an Ultrathin Strut Biodegradable Polymer Sirolimus-Eluting Stent With a Durable Polymer Everolimus-Eluting Stent for Patients With Acute ST-Segment Elevation Myocardial Infarction Undergoing Primary Percutaneous Coronary Intervention [BIOSTEMI]; NCT02579031).
Collapse
Affiliation(s)
- Thomas Pilgrim
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Olivier Muller
- Department of Cardiology, Lausanne University Hospital, Lausanne, Switzerland
| | - Dik Heg
- CTU Bern, University of Bern, Bern, Switzerland
| | - Marco Roffi
- Division of Cardiology, Geneva University Hospitals, Geneva, Switzerland
| | - David J Kurz
- Department of Cardiology, Triemli Hospital, Zurich, Switzerland
| | - Igal Moarof
- Department of Cardiology, Kantonsspital, Aarau, Switzerland
| | | | - Christoph Kaiser
- Department of Cardiology, Basel University Hospital, Basel, Switzerland
| | | | | | - Eric Eeckhout
- Department of Cardiology, Lausanne University Hospital, Lausanne, Switzerland
| | - Marco Valgimigli
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Peter Jüni
- Applied Health Research Centre, Li Ka Shing Knowledge Institute of St. Michael's Hospital, Department of Medicine and Institute of Health Policy, Management and Evaluation, University of Toronto, Toronto, Ontario, Canada
| | - Stephan Windecker
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Juan F Iglesias
- Division of Cardiology, Geneva University Hospitals, Geneva, Switzerland.
| |
Collapse
|
5
|
Iglesias JF, Muller O, Losdat S, Roffi M, Kurz DJ, Weilenmann D, Kaiser C, Heg D, Valgimigli M, Windecker S, Pilgrim T. Multivessel percutaneous coronary intervention with thin-strut biodegradable versus durable polymer drug-eluting stents in ST-segment elevation myocardial infarction: A subgroup analysis of the BIOSTEMI randomized trial. Int J Cardiol 2021; 334:37-41. [PMID: 33887341 DOI: 10.1016/j.ijcard.2021.04.034] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/26/2020] [Revised: 03/29/2021] [Accepted: 04/16/2021] [Indexed: 10/21/2022]
Abstract
BACKGROUND Randomized evidence comparing newer-generation drug-eluting stents for multivessel percutaneous coronary intervention (PCI) in patients with ST-segment elevation myocardial infarction (STEMI) is limited. We sought to investigate clinical outcomes in STEMI patients undergoing multivessel PCI with thin-strut biodegradable polymer sirolimus-eluting stents (BP-SES) versus durable polymer everolimus-eluting stents (DP-EES). METHODS We performed a subgroup analysis of the BIOSTEMI (NCT02579031) randomized trial, which included individual patient data from STEMI patients enrolled into the BIOSCIENCE (NCT02579031) study. STEMI patients randomly allocated to BP-SES or DP-EES were divided into those undergoing multivessel versus culprit lesion-only PCI. The primary endpoint was target lesion failure (TLF), a composite of cardiac death, target vessel myocardial re-infarction or clinically indicated target lesion revascularization (TLR), within 24 months. RESULTS Among 1707 STEMI patients, 145 patients underwent multivessel PCI. At 2 years, TLF occurred in 2 patients (2.8%) treated with BP-SES and 13 patients (18.7%) treated with DP-EES (hazard ratio [HR], 0.14; 95% confidence interval (CI), 0.03-0.61; p = 0.009) in the multivessel PCI group, and in 40 (5.3%) and 61 (8.2%) patients treated with BP-SES and DP-EES respectively (HR, 0.64; 95%CI, 0.43-0.96; p = 0.03; p for interaction = 0.050) in the culprit lesion-only PCI group. In the multivessel PCI group, the rates of clinically indicated TLR (0% vs. 12.4%) and target vessel myocardial re-infarction (0% vs. 4.6%) at 2 years were lower in patients treated with BP-SES compared with DP-EES. CONCLUSION In a subgroup analysis of the BIOSTEMI trial, BP-SES were associated with lower 2-year TLF rates compared to DP-EES in STEMI patients undergoing multivessel PCI.
Collapse
Affiliation(s)
- Juan F Iglesias
- Division of Cardiology, Geneva University Hospitals, Geneva, Switzerland.
| | - Olivier Muller
- Department of Cardiology, Lausanne University Hospital, Lausanne, Switzerland
| | | | - Marco Roffi
- Division of Cardiology, Geneva University Hospitals, Geneva, Switzerland
| | - David J Kurz
- Department of Cardiology, Triemlispital, Zurich, Switzerland
| | | | - Christoph Kaiser
- Department of Cardiology, Basel University Hospital, Basel, Switzerland
| | - Dik Heg
- CTU Bern, University of Bern, Bern, Switzerland
| | - Marco Valgimigli
- Department of Cardiology, Inselspital, Bern University Hospital, Bern, Switzerland
| | - Stephan Windecker
- Department of Cardiology, Inselspital, Bern University Hospital, Bern, Switzerland
| | - Thomas Pilgrim
- Department of Cardiology, Inselspital, Bern University Hospital, Bern, Switzerland
| |
Collapse
|
6
|
Kim YH, Her AY, Jeong MH, Kim BK, Hong SJ, Kim S, Ahn CM, Kim JS, Ko YG, Choi D, Hong MK, Jang Y. Comparison of Durable-Polymer- and Biodegradable-Polymer-Based Newer-Generation Drug-Eluting Stents in Patients with Acute Myocardial Infarction and Prediabetes After Successful Percutaneous Coronary Intervention. Int Heart J 2020; 61:673-684. [PMID: 32684595 DOI: 10.1536/ihj.19-654] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Hyperglycemia is an important risk factor for poor clinical outcomes in patients with acute myocardial infarction (AMI). The relative superiority of the long-term clinical outcomes of durable-polymer (DP) -based and biodegradable-polymer (BP) -based newer-generation drug-eluting stents (DESs) after successful percutaneous coronary intervention (PCI) in patients with AMI and prediabetes is not well established. We compared the clinical outcomes in such patients between DP-based and BP-based newer-generation DESs.A total of 4,377 patients with AMI and prediabetes were divided into the following two groups: the DP-DES group (n = 3,775; zotarolimus-eluting stents [ZES; n = 1,546] and everolimus-eluting stents [EES; n = 2,229]) and the BP-DES group (n = 602; biolimus-eluting stents [BES]). The primary endpoint was the occurrence of major adverse cardiac events (MACEs), defined as all-cause death, recurrent myocardial infarction (re-MI), or any repeat revascularization. The secondary endpoint was the occurrence of stent thrombosis (ST).The 2-year adjusted hazard ratio (aHR) of MACEs for ZES versus EES, ZES versus BES, EES versus BES, and ZES/EES versus BES (aHR: 1.125; 95% confidence interval [CI], 0.834-1.518; P = 0.440) were similar. The cumulative incidence of ST was also comparable between the DP-DES and BP-DES groups (aHR: 1.407; 95% CI, 0.476-4.158; P = 0.537). Moreover, the 2-year aHRs of all-cause death, CD, re-MI, target lesion revascularization (TLR), target vessel revascularization (TVR), and non-TVR were similar.Patients with AMI and prediabetes who received DP-DES or BP-DES during PCI showed comparable safety and efficacy during the 2-year follow-up period.
Collapse
Affiliation(s)
- Yong Hoon Kim
- Division of Cardiology, Department of Internal Medicine, Kangwon National University School of Medicine
| | - Ae-Young Her
- Division of Cardiology, Department of Internal Medicine, Kangwon National University School of Medicine
| | - Myung Ho Jeong
- Department of Cardiology, Cardiovascular Center, Chonnam National University Hospital
| | - Byeong-Keuk Kim
- Division of Cardiology, Severance Cardiovascular Hospital, Yonsei University College of Medicine
| | - Sung-Jin Hong
- Division of Cardiology, Severance Cardiovascular Hospital, Yonsei University College of Medicine
| | - Seunghwan Kim
- Division of Cardiology, Inje University College of Medicine, Haeundae Paik Hospital
| | - Chul-Min Ahn
- Division of Cardiology, Severance Cardiovascular Hospital, Yonsei University College of Medicine
| | - Jung-Sun Kim
- Division of Cardiology, Severance Cardiovascular Hospital, Yonsei University College of Medicine
| | - Young-Guk Ko
- Division of Cardiology, Severance Cardiovascular Hospital, Yonsei University College of Medicine
| | - Donghoon Choi
- Division of Cardiology, Severance Cardiovascular Hospital, Yonsei University College of Medicine
| | - Myeong-Ki Hong
- Division of Cardiology, Severance Cardiovascular Hospital, Yonsei University College of Medicine
| | - Yangsoo Jang
- Division of Cardiology, Severance Cardiovascular Hospital, Yonsei University College of Medicine
| |
Collapse
|
7
|
The Orsiro Ultrathin, Bioresorbable-Polymer Sirolimus-Eluting Stent: A Review of Current Evidence. CARDIOVASCULAR REVASCULARIZATION MEDICINE 2020; 21:540-548. [PMID: 31952919 DOI: 10.1016/j.carrev.2019.12.039] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2019] [Revised: 12/19/2019] [Accepted: 12/30/2019] [Indexed: 11/23/2022]
Abstract
Advances in stent design and the development of bioresorbable polymers have allowed the development of novel stent technologies such as the Orsiro bioresorbable-polymer sirolimus eluting stent (BP-SES). Over several noninferiority trials, the BP-SES has demonstrated itself to be a safe and effective therapy for obstructive coronary artery disease. This article reviews the current evidence of the efficacy of the BP-SES and examines its performance in high-risk populations, such as patients presenting with ST-segment myocardial infarction, chronic total occlusions, diabetes, and small vessel disease.
Collapse
|
8
|
Iglesias JF, Muller O, Heg D, Roffi M, Kurz DJ, Moarof I, Weilenmann D, Kaiser C, Tapponnier M, Stortecky S, Losdat S, Eeckhout E, Valgimigli M, Odutayo A, Zwahlen M, Jüni P, Windecker S, Pilgrim T. Biodegradable polymer sirolimus-eluting stents versus durable polymer everolimus-eluting stents in patients with ST-segment elevation myocardial infarction (BIOSTEMI): a single-blind, prospective, randomised superiority trial. Lancet 2019; 394:1243-1253. [PMID: 31488372 DOI: 10.1016/s0140-6736(19)31877-x] [Citation(s) in RCA: 131] [Impact Index Per Article: 26.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/12/2019] [Revised: 07/24/2019] [Accepted: 07/26/2019] [Indexed: 12/16/2022]
Abstract
BACKGROUND Newer-generation drug-eluting stents that combine ultrathin strut metallic platforms with biodegradable polymers might facilitate vascular healing and improve clinical outcomes in patients with acute myocardial infarction undergoing primary percutaneous coronary intervention (PCI) compared with contemporary thin strut second-generation drug-eluting stents. We did a randomised clinical trial to investigate the safety and efficacy of ultrathin strut biodegradable polymer sirolimus-eluting stents versus thin strut durable polymer everolimus-eluting stents in patients with acute ST-segment elevation myocardial infarction (STEMI) undergoing primary PCI. METHODS The BIOSTEMI trial was an investigator-initiated, multicentre, prospective, single-blind, randomised superiority trial at ten hospitals in Switzerland. Patients aged 18 years or older with acute STEMI who were referred for primary PCI were eligible to participate. Patients were randomly allocated (1:1) to either biodegradable polymer sirolimus-eluting stents or durable polymer everolimus-eluting stents. Central randomisation was done based on a computer-generated allocation sequence with variable block sizes of 2, 4, and 6, which was stratified by centre, diabetes status, and presence or absence of multivessel coronary artery disease, and concealed using a secure web-based system. Patients and treating physicians were aware of group allocations, whereas outcome assessors were masked to the allocated stent. The experimental stent (Orsiro; Biotronik; Bülach, Switzerland) consisted of an ultrathin strut cobalt-chromium metallic stent platform releasing sirolimus from a biodegradable polymer. The control stent (Xience Xpedition/Alpine; Abbott Vascular, Abbott Park, IL, USA) consisted of a thin strut cobalt-chromium stent platform that releases everolimus from a durable polymer. The primary endpoint was target lesion failure, a composite of cardiac death, target vessel myocardial reinfarction (Q-wave and non-Q-wave), and clinically-indicated target lesion revascularisation, within 12 months of the index procedure. All analyses were done with the individual participant as the unit of analysis and according to the intention-to-treat principle. The trial was registered with ClinicalTrials.gov, number NCT02579031. FINDINGS Between April 26, 2016, and March 9, 2018, we randomly assigned 1300 patients (1623 lesions) with acute myocardial infarction to treatment with biodegradable polymer sirolimus-eluting stents (649 patients and 816 lesions) or durable polymer everolimus-eluting stents (651 patients and 806 lesions). At 12 months, follow-up data were available for 614 (95%) patients treated with biodegradable polymer sirolimus-eluting stents and 626 (96%) patients treated with durable polymer everolimus-eluting stents. The primary composite endpoint of target lesion failure occurred in 25 (4%) of 649 patients treated with biodegradable polymer sirolimus-eluting stents and 36 (6%) of 651 patients treated with durable polymer everolimus-eluting stents (difference -1·6 percentage points; rate ratio 0·59, 95% Bayesian credibility interval 0·37-0·94; posterior probability of superiority 0·986). Cardiac death, target vessel myocardial reinfarction, clinically-indicated target lesion revascularisation, and definite stent thrombosis were similar between the two treatment groups in the 12 months of follow-up. INTERPRETATION In patients with acute STEMI undergoing primary PCI, biodegradable polymer sirolimus-eluting stents were superior to durable polymer everolimus-eluting stents with respect to target lesion failure at 1 year. This difference was driven by reduced ischaemia-driven target lesion revascularisation in patients treated with biodegradable polymer sirolimus-eluting stents compared with durable polymer everolimus-eluting stents. FUNDING Biotronik.
Collapse
Affiliation(s)
- Juan F Iglesias
- Division of Cardiology, Geneva University Hospitals, Geneva, Switzerland
| | - Olivier Muller
- Department of Cardiology, Lausanne University Hospital, Lausanne, Switzerland
| | - Dik Heg
- Clinical Trials Unit Bern, University of Bern, Bern, Switzerland
| | - Marco Roffi
- Division of Cardiology, Geneva University Hospitals, Geneva, Switzerland
| | - David J Kurz
- Department of Cardiology, Triemli Hospital, Zurich, Switzerland
| | - Igal Moarof
- Department of Cardiology, Kantonsspital, Aarau, Switzerland
| | | | - Christoph Kaiser
- Department of Cardiology, Basel University Hospital, Basel, Switzerland
| | | | - Stefan Stortecky
- Department of Cardiology, Inselspital, Bern University Hospital, Bern, Switzerland
| | - Sylvain Losdat
- Clinical Trials Unit Bern, University of Bern, Bern, Switzerland
| | - Eric Eeckhout
- Department of Cardiology, Lausanne University Hospital, Lausanne, Switzerland
| | - Marco Valgimigli
- Department of Cardiology, Inselspital, Bern University Hospital, Bern, Switzerland
| | - Ayodele Odutayo
- Applied Health Research Centre, Li Ka Shing Knowledge Institute of St Michael's Hospital, Department of Medicine and Institute of Health Policy, Management and Evaluation, University of Toronto, Toronto, Canada
| | - Marcel Zwahlen
- Institute of Social and Preventive Medicine, University of Bern, Bern, Switzerland
| | - Peter Jüni
- Applied Health Research Centre, Li Ka Shing Knowledge Institute of St Michael's Hospital, Department of Medicine and Institute of Health Policy, Management and Evaluation, University of Toronto, Toronto, Canada
| | - Stephan Windecker
- Department of Cardiology, Inselspital, Bern University Hospital, Bern, Switzerland.
| | - Thomas Pilgrim
- Department of Cardiology, Inselspital, Bern University Hospital, Bern, Switzerland
| |
Collapse
|
9
|
Häner JD, Räber L, Windecker S. Biodegradable vs. permanent polymer drug-eluting stents: the need for a new nomenclature to classify drug-eluting stent technology. Eur Heart J 2019; 40:2616-2619. [PMID: 31132081 DOI: 10.1093/eurheartj/ehz330] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Abstract
Collapse
Affiliation(s)
- Jonas Dominik Häner
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Lorenz Räber
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Stephan Windecker
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| |
Collapse
|
10
|
Cassese S, Ndrepepa G, Byrne RA, Kufner S, Lahmann AL, Mankerious N, Xhepa E, Laugwitz KL, Schunkert H, Fusaro M, Kastrati A, Joner M. Outcomes of patients treated with ultrathin-strut biodegradable polymer sirolimus-eluting stents versus fluoropolymer-based everolimus-eluting stents: a meta-analysis of randomised trials. EUROINTERVENTION 2019. [PMID: 29537375 DOI: 10.4244/eij-d-18-00024] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
AIMS The ultrathin-strut biodegradable polymer sirolimus-eluting stent (SES) is a new-generation drug-eluting stent (DES) developed to improve the percutaneous treatment of patients with coronary artery disease. Here, we sought to investigate whether the performance of the ultrathin-strut biodegradable polymer SES is superior to that of the benchmark thin-strut fluoropolymer-based everolimus-eluting stent (EES). METHODS AND RESULTS We undertook a study-level meta-analysis of trials in which patients receiving percutaneous coronary intervention (PCI) were randomly assigned to either SES or EES. Primary efficacy and safety outcomes were target lesion revascularisation (TLR) and definite/probable stent thrombosis (ST), respectively. Secondary outcomes were myocardial infarction (MI), death, target lesion failure (TLF) and target vessel failure (TVF). A total of 4,853 patients received a PCI with either SES (n=2,816) or EES (n=2,037) in six trials. After a weighted median follow-up of 12 months, patients treated with SES had a risk of TLR (odds ratio [95% confidence interval]: 1.24 [0.83-1.85], p=0.30), definite/probable ST (0.84 [0.53-1.33], p=0.45) and MI related to the target vessel (0.77 [0.55-1.07], p=0.12) comparable to that of patients treated with EES. We found no significant difference with regard to other secondary outcomes. CONCLUSIONS At one-year follow-up, the ultrathin-strut biodegradable polymer sirolimus-eluting stent displays a performance comparable to that of the fluoropolymer-based everolimus-eluting stent.
Collapse
Affiliation(s)
- Salvatore Cassese
- Deutsches Herzzentrum München, Technische Universität München, Munich, Germany
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
11
|
Cassese S, Lahmann AL, Joner M. Ultrathin strut biodegradable-polymer sirolimus-eluting stents: being wary or going with the flow? J Thorac Dis 2018; 10:688-692. [PMID: 29607135 DOI: 10.21037/jtd.2018.01.118] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Affiliation(s)
- Salvatore Cassese
- Deutsches Herzzentrum München, Technische Universität München, Munich, Germany
| | - Anna Lena Lahmann
- Deutsches Herzzentrum München, Technische Universität München, Munich, Germany
| | - Michael Joner
- Deutsches Herzzentrum München, Technische Universität München, Munich, Germany.,DZHK (German Centre for Cardiovascular Research), Partner Site Munich Heart Alliance, Munich, Germany
| |
Collapse
|