1
|
Meier D, Toggweiler S, Muller O, Fournier S. Long-term Outcomes After Transcatheter Aortic Valve Replacement: Are All Platforms Equal? Can J Cardiol 2024:S0828-282X(24)01242-X. [PMID: 39638145 DOI: 10.1016/j.cjca.2024.12.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2024] [Revised: 11/30/2024] [Accepted: 12/02/2024] [Indexed: 12/07/2024] Open
Affiliation(s)
- David Meier
- Department of Cardiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
| | - Stefan Toggweiler
- Heart Center Lucerne, Luzerner Kantonsspital, Lucerne, Switzerland. https://twitter.com/Toggweiler
| | - Olivier Muller
- Department of Cardiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland. https://twitter.com/Muller
| | - Stephane Fournier
- Department of Cardiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland. https://twitter.com/Fournier
| |
Collapse
|
2
|
Ordoñez S, Chu MWA, Diamantouros P, Valdis M, Chaumont G, Vila RCB, Teefy P, Bagur R. Next-Day Discharge After Transcatheter Aortic Valve Implantation With the ACURATE neo/neo2 Self-Expanding Aortic Bioprosthesis. Am J Cardiol 2024; 227:65-74. [PMID: 38996897 DOI: 10.1016/j.amjcard.2024.07.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/18/2023] [Revised: 06/29/2024] [Accepted: 07/08/2024] [Indexed: 07/14/2024]
Abstract
Previous studies have shown the safety of early discharge pathways in selected patients and using selected transcatheter heart valves. Hence, we sought to evaluate the safety of next-day discharge (NDD) in patients who underwent transfemoral transcatheter aortic valve implantation (TF-TAVI) with the ACURATE neo/neo2 (Boston Scientific, Marlborough, Massachusetts) self-expanding aortic bioprosthesis. Patients who underwent TF-TAVI between January 2018 and April 2023 were prospectively included. Patients were stratified into 3 groups according to discharge times within 24 hours (NDD), between 24 and 48 hours, and those discharged >48 hours after TAVI. The primary outcome was the first unplanned readmission at 30 days after TAVI. Log-rank test was used to assess the differences in the outcome of interest between the groups. A total of 368 all-comers were included in this study. According to discharge times, 204 patients followed NDD, 69 patients 24 to 48 hours discharge, and 95 patients >48 hours discharge after TAVI. The mean age was 84 ± 6.3 years and 61% were women, without differences between the groups. The mean Society of Thoracic Surgeons score was lower in those with NDD versus 24 to 48 hours and >48 hours (2.9 ± 1.0, 3.2 ± 1.2, and 3.4 ± 1.4, respectively, p = 0.014). There were no differences between the groups in terms of preprocedural right bundle branch block or pacemaker. The need for new permanent pacemaker implantation was the leading postprocedural complication; it occurred more frequently in the >48 hours group than the 24 to 48 hours, and <24 hours groups (24% vs 8.6% and 2.2%, p <0.001). There were 5 strokes (1.4%) and all of them occurred in the >48 hours group (p = 0.005). At 30 days after discharge, there were no deaths and no differences in all-cause readmissions (9.3% in <24 hours, 8.6% in 24 to 48 hours, and 19% in >48 hours, log-rank p = 0.087). The readmission rates for new permanent pacemaker implantation requirement were 3.3% (n = 6) in NDD, 0% in 24 to 48 hours, and 1.6% (n = 5) in the >48 hours groups (p = 0.27). In conclusion, in unselected patients who underwent TF-TAVI with the ACURATE neo/neo2 self-expanding bioprosthesis, the NDD pathway is feasible and appears to be safe, without an increased risk of death or all-cause rehospitalization through 30 days after hospital discharge.
Collapse
Affiliation(s)
- Santiago Ordoñez
- Heart Team, London Health Sciences Centre, Western University, London, Ontario, Canada
| | - Michael W A Chu
- Heart Team, London Health Sciences Centre, Western University, London, Ontario, Canada
| | - Pantelis Diamantouros
- Heart Team, London Health Sciences Centre, Western University, London, Ontario, Canada
| | - Matthew Valdis
- Heart Team, London Health Sciences Centre, Western University, London, Ontario, Canada
| | - Gloria Chaumont
- Heart Team, London Health Sciences Centre, Western University, London, Ontario, Canada
| | | | - Patrick Teefy
- Heart Team, London Health Sciences Centre, Western University, London, Ontario, Canada
| | - Rodrigo Bagur
- Heart Team, London Health Sciences Centre, Western University, London, Ontario, Canada.
| |
Collapse
|
3
|
Eckel C, Kim WK, Schlüter J, Renker M, Bargon S, Grothusen C, Elsässer A, Dohmen G, Choi YH, Charitos EI, Hamm CW, Sossalla S, Möllmann H, Blumenstein J. Impact of Accidental High or Low Implantation Depth on Peri-Procedural Outcomes after Implantation with the Self-Expanding ACURATE neo2. J Clin Med 2024; 13:5342. [PMID: 39274553 PMCID: PMC11396697 DOI: 10.3390/jcm13175342] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2024] [Revised: 08/15/2024] [Accepted: 08/24/2024] [Indexed: 09/16/2024] Open
Abstract
Background: Precise implantation could play a crucial role in the technical success of transcatheter aortic valve replacement (TAVR) for some prostheses. The impact of an accidental implantation depth (ID) outside the recommended range has not been assessed for the ACURATE neo2 (NEO2). Methods: Data from 1839 patients with severe native aortic stenosis treated with the NEO2 prosthesis were evaluated. We compared the results of prostheses implanted in an ID both inside and outside the recommendations. The outcome assessment followed the Valve Academic Research Consortium-3 criteria. Results: Patients were retrospectively divided into high (<3 mm; n = 412), optimal (3-7 mm; n = 1236), and low (>7 mm; n = 169) implantations. Technical success (94.7% vs. 94.7% vs. 91.7%, p = 0.296) and device success were high (90.1% vs. 89.3% vs. 84.6%, p = 0.112) without differences between groups. Rates of relevant paravalvular regurgitation (PVL; >mild or VinV due to PVL) were comparable (1.2% vs. 1.8% vs. 1.2%, p = 0.759). Even when hemodynamics were superior in the high-implantation group, with greater iEOA (1.01 cm2/m2 vs. 0.95 cm2/m2 vs. 0.92 cm2/m2, p < 0.001), spontaneous embolization or after post-dilatation was more common. Low implantation was associated with a higher rate of associated pacemaker implantation (PPI) (6.1% vs. 8.8% vs. 14.8%, p = 0.001). Conclusions: Implantation with the ACURATE neo2 showed excellent hemodynamic results, including low gradients and a small number of relevant PVL, in line with a high technical success rate that was irrespective of the ID. A favorable outcome can also be achieved in accidental low or high positions. Low implantation was associated with a higher rate of associated pacemaker implantation. Deliberately high implantation should be avoided due to the risk of embolization.
Collapse
Affiliation(s)
- Clemens Eckel
- Department of Cardiology, St. Johannes Hospital, 44137 Dortmund, Germany
- School VI-School of Medicine and Health Sciences, Carl von Ossietzky Universität Oldenburg, 26129 Oldenburg, Germany
| | - Won-Keun Kim
- Department of Cardiology, Kerckhoff Heart Center, 61231 Bad Nauheim, Germany
- Department of Cardiology, Justus-Liebig University of Giessen, 35390 Giessen, Germany
| | - Judith Schlüter
- Department of Cardiology, St. Johannes Hospital, 44137 Dortmund, Germany
| | - Matthias Renker
- Department of Cardiology, Kerckhoff Heart Center, 61231 Bad Nauheim, Germany
- Department of Cardiac Surgery, Kerckhoff Heart Center, 61231 Bad Nauheim, Germany
| | - Sophie Bargon
- Department of Cardiology, St. Johannes Hospital, 44137 Dortmund, Germany
| | - Christina Grothusen
- Department of Cardiology, St. Johannes Hospital, 44137 Dortmund, Germany
- Department of Cardiac Surgery, University of Kiel, 24118 Kiel, Germany
| | - Albrecht Elsässer
- School VI-School of Medicine and Health Sciences, Carl von Ossietzky Universität Oldenburg, 26129 Oldenburg, Germany
| | - Guido Dohmen
- Department of Cardiac Surgery, St. Johannes Hospital, 44137 Dortmund, Germany
| | - Yeong-Hoon Choi
- Department of Cardiac Surgery, Kerckhoff Heart Center, 61231 Bad Nauheim, Germany
| | | | - Christian W Hamm
- Department of Cardiology, Kerckhoff Heart Center, 61231 Bad Nauheim, Germany
- Department of Cardiology, Justus-Liebig University of Giessen, 35390 Giessen, Germany
| | - Samuel Sossalla
- Department of Cardiology, Kerckhoff Heart Center, 61231 Bad Nauheim, Germany
- Department of Cardiology, Justus-Liebig University of Giessen, 35390 Giessen, Germany
| | - Helge Möllmann
- Department of Cardiology, St. Johannes Hospital, 44137 Dortmund, Germany
| | - Johannes Blumenstein
- Department of Cardiology, St. Johannes Hospital, 44137 Dortmund, Germany
- School VI-School of Medicine and Health Sciences, Carl von Ossietzky Universität Oldenburg, 26129 Oldenburg, Germany
| |
Collapse
|
4
|
Kroon HG, Hokken T, van Wiechen M, Ooms JFW, van Gils L, Kardys I, Daemen J, De Jaegere PPT, Nuis RJ, Van Mieghem NM. Conduction dynamics over time after transcatheter aortic valve replacement: An expert review. CARDIOVASCULAR REVASCULARIZATION MEDICINE 2024:S1553-8389(24)00625-0. [PMID: 39299841 DOI: 10.1016/j.carrev.2024.08.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2024] [Revised: 07/27/2024] [Accepted: 08/13/2024] [Indexed: 09/22/2024]
Abstract
New conduction disorders remain a frequent complication in current transcatheter aortic valve replacement (TAVR) era. Left bundle branch block (LBBB) occurs early in about 20-30 % of TAVR-patients, persists at 1 month in about 35-45 % of cases and will likely remain thereafter. Third-degree atrioventricular block (AV3B) affects approximately 15 % of patients. Pacemaker dependency gradually decreases throughout follow-up and approximately 25-35 % of patients remain pacemaker dependent at one year. We aimed to review what is currently known about the dynamics of acquired conduction disorders, including extraction of predictors, and how to interpret these dynamics in light of an early discharge policy.
Collapse
Affiliation(s)
- Herbert G Kroon
- Department of Cardiology, Erasmus University Medical Center, Rotterdam, the Netherlands
| | - Thijmen Hokken
- Department of Cardiology, Erasmus University Medical Center, Rotterdam, the Netherlands
| | - Maarten van Wiechen
- Department of Cardiology, Erasmus University Medical Center, Rotterdam, the Netherlands
| | - Joris F W Ooms
- Department of Cardiology, Erasmus University Medical Center, Rotterdam, the Netherlands
| | - Lennart van Gils
- Department of Cardiology, Erasmus University Medical Center, Rotterdam, the Netherlands
| | - Isabella Kardys
- Department of Cardiology, Erasmus University Medical Center, Rotterdam, the Netherlands
| | - Joost Daemen
- Department of Cardiology, Erasmus University Medical Center, Rotterdam, the Netherlands
| | - Peter P T De Jaegere
- Department of Cardiology, Erasmus University Medical Center, Rotterdam, the Netherlands
| | - Rutger-Jan Nuis
- Department of Cardiology, Erasmus University Medical Center, Rotterdam, the Netherlands
| | - Nicolas M Van Mieghem
- Department of Cardiology, Erasmus University Medical Center, Rotterdam, the Netherlands.
| |
Collapse
|
5
|
Nuis RJ, van den Dorpel M, Adrichem R, Daemen J, Van Mieghem N. Conduction Abnormalities after Transcatheter Aortic Valve Implantation: Incidence, Impact and Management Using CT Data Interpretation. Interv Cardiol 2024; 19:e12. [PMID: 39221063 PMCID: PMC11363062 DOI: 10.15420/icr.2024.11] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2024] [Accepted: 06/09/2024] [Indexed: 09/04/2024] Open
Abstract
The demonstrated safety and effectiveness of transcatheter aortic valve implantation (TAVI) among low surgical risk patients opened the road to its application in younger low-risk patients. However, the occurrence of conduction abnormalities and need for permanent pacemaker implantation remains a frequent problem associated with adverse outcomes. The clinical implications may become greater when TAVI shifts towards younger populations, highlighting the need for comprehensive strategies to address this issue. Beyond currently available clinical and electrocardiographic predictors, patient-specific anatomical assessment of the aortic root using multi-sliced CT (MSCT) imaging can refine risk stratification. Moreover, leveraging MSCT data for computational 3D simulations to predict device-anatomy interactions may help guide procedural strategy to mitigate conduction abnormalities. The aims of this review are to summarise the incidence and clinical impact of new left bundle branch block and permanent pacemaker implantation post-TAVI using contemporary transcatheter heart valves; and highlight the value of MSCT data interpretation to improve the management of this complication.
Collapse
Affiliation(s)
- Rutger-Jan Nuis
- Department of Cardiology, Thoraxcenter, Erasmus University Medical Center Rotterdam, the Netherlands
| | - Mark van den Dorpel
- Department of Cardiology, Thoraxcenter, Erasmus University Medical Center Rotterdam, the Netherlands
| | - Rik Adrichem
- Department of Cardiology, Thoraxcenter, Erasmus University Medical Center Rotterdam, the Netherlands
| | - Joost Daemen
- Department of Cardiology, Thoraxcenter, Erasmus University Medical Center Rotterdam, the Netherlands
| | - Nicolas Van Mieghem
- Department of Cardiology, Thoraxcenter, Erasmus University Medical Center Rotterdam, the Netherlands
| |
Collapse
|
6
|
Travieso A, Toggweiler S, Montarello N, Renker M, Tirado-Conte G, Loretz L, Charitos EI, Kim WK, De Backer O. Commissural alignment and the ACURATE neo2 transcatheter aortic valve: Impact on valve performance. Catheter Cardiovasc Interv 2024; 104:115-124. [PMID: 38764320 DOI: 10.1002/ccd.31089] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/15/2023] [Revised: 02/26/2024] [Accepted: 05/08/2024] [Indexed: 05/21/2024]
Abstract
BACKGROUND Transcatheter aortic valve replacement (TAVR) is increasingly being used to treat severe aortic stenosis in younger patients. Accordingly, lifetime management regarding future reintervention and coronary access is a concern. AIMS To assess the impact of commissural alignment on ACURATE neo2 transcatheter aortic valve (TAV) performance. METHODS COMALIGN-neo2 was an observational, retrospective study enrolling consecutive TAVR patients treated with the ACURATE neo2 (October 2021 to October 2022). The degree of commissural (mis)-alignment (CMA) with the native aortic valve commissures was determined and transvalvular gradient, effective orifice area, patient-prosthesis mismatch (PPM), and aortic regurgitation (AR) were assessed. RESULTS Among 825 patients, the mean age was 80.7 years and 42% were female. Commissural alignment was achieved in 60% of cases; mild (26%), moderate (9%), and severe misalignment (5%) were found less often. Severe PPM occurred more frequently in patients with severe CMA (14.7%) compared to aligned valves (p = 0.034). By multivariate analysis, severe CMA (odds ratio [OR]: 3.12, 95% confidence interval [CI] [1.09-8.90]; p = 0.033) and lack of postdilatation (OR: 3.85, [1.33-11.1]; p = 0.012) were associated with severe PPM. Higher rates of ≥mild AR (51.4%) were found in TAVs implanted with severe CMA compared to aligned (34.3%), mildly (38.1%) or moderately (36.0%) misaligned TAVs (p = 0.030). Multivariate analysis identified severe CMA (OR: 2.05, [1.05-4.02]; p = 0.037) to be an independent predictor of ≥mild AR. CONCLUSIONS COMALIGN-neo2 is the largest study to date assessing the impact of commissural alignment on acute TAV performance. Severe CMA with the ACURATE neo2 platform was associated with worse valve hemodynamics and increased risk for mild AR.
Collapse
Affiliation(s)
| | | | | | - Matthias Renker
- Department of Cardiology, Kerckhoff Heart Center, Bad Nauheim, Germany
- Department of Cardiac Surgery, Kerckhoff Heart Center, Bad Nauheim, Germany
- DZHK (German Center for Cardiovascular Research), Site Rhein-Main, Bad Nauheim, Germany
| | | | - Lucca Loretz
- Heart Center Lucerne, Lucerner Kantonsspital, Lucerne, Switzerland
| | | | - Won-Keun Kim
- Department of Cardiology, Kerckhoff Heart Center, Bad Nauheim, Germany
- Department of Cardiac Surgery, Kerckhoff Heart Center, Bad Nauheim, Germany
- DZHK (German Center for Cardiovascular Research), Site Rhein-Main, Bad Nauheim, Germany
- Department of Cardiology, Justus Liebig University of Giessen and Marburg, Giessen, Germany
| | - Ole De Backer
- The Heart Center, Rigshospitalet, Copenhagen, Denmark
| |
Collapse
|
7
|
Sultan I, Reardon MJ, Søndergaard L, Chehab B, Smith D, Walton AS, Worthley SG, Manoharan G, Yong G, Jilaihawi H, Asch F, Bates N, Fontana GP. Predictors and Trends of New Permanent Pacemaker Implantation: A Subanalysis of the International Navitor IDE Study. STRUCTURAL HEART : THE JOURNAL OF THE HEART TEAM 2024; 8:100293. [PMID: 39100579 PMCID: PMC11294828 DOI: 10.1016/j.shj.2024.100293] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/29/2023] [Revised: 01/14/2024] [Accepted: 02/01/2024] [Indexed: 08/06/2024]
Abstract
Background The Navitor Investigational Device Exemption (IDE) study is a prospective, multicenter, global study assessing the safety and effectiveness of the Navitor valve in a population with severe, symptomatic aortic stenosis who are at high and extreme surgical risk. The impact of pre-existing conduction abnormalities and implantation technique on new permanent pacemaker implantation (PPI) for the Navitor platform is not fully understood. Therefore, the goal of this analysis was to investigate the associations between patient and procedural factors and the 30-day new PPI rate. Methods A total of 260 patients who underwent implantation of a Navitor valve in the Navitor IDE study were reviewed. Patients with preprocedural permanent pacemakers (n = 28) were excluded. Baseline risk factors were assessed for statistical significance. Multivariable logistic regression analyses were performed to identify independent predictors of new PPI. Results Mean age of the pacemaker-naïve population was 83.3 ± 5.2 years, 58.6% were female, average Society of Thoracic Surgeons score was 3.8% ± 1.9%, median frailty score was 1 (interquartile range 1, 2), and 17.7% were deemed at extreme surgical risk. Pre-existing first-degree atrioventricular block and right bundle branch block significantly increased the risk of new PPI postimplantation, whereas left bundle branch block did not. Membranous septum length in relation to noncoronary cusp implant depth was a significant predictor of new PPI, with higher rates of new PPI observed when noncoronary cusp implant depth exceeded membranous septum length. Analysis of implant depth alone revealed deeper implants were associated with a higher rate of new PPI, regardless of patient baseline conduction abnormality. Conclusions The 30-day rate of new PPI in the Navitor IDE study is associated with patient pre-existing baseline conduction disturbances and implantation depth.
Collapse
Affiliation(s)
- Ibrahim Sultan
- Division of Cardiac Surgery, Department of Cardiothoracic Surgery, Heart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA
| | - Michael J. Reardon
- Department of Cardiovascular Surgery, Houston Methodist DeBakey Heart and Vascular Center, Houston, Texas, USA
| | - Lars Søndergaard
- Structural Heart Medical Affairs, Abbott Medical, Santa Clara, California, USA
| | - Bassem Chehab
- Department of Cardiology, Ascension Via Christi Hospital, University of Kansas, Wichita, Kansas, USA
| | - Dave Smith
- Morriston Hospital, Swansea Bay University Health Board, Swansea, UK
| | - Antony S. Walton
- Department of Interventional Cardiology, Alfred Hospital, Melbourne, Victoria, Australia
- Monash University, Melbourne, Victoria, Australia
| | - Stephen G. Worthley
- Department of Cardiology, Macquarie University Hospital, Macquarie Park, New South Wales, Australia
| | - Ganesh Manoharan
- Regional Cardiology Centre, Royal Victoria Hospital, Belfast, UK
| | - Gerald Yong
- Department of Cardiology, Fiona Stanley Hospital, Murdoch, Western Australia, Australia
| | - Hasan Jilaihawi
- Department of Cardiology, Cedars-Sinai Medical Center, Los Angeles, California, USA
| | - Federico Asch
- Cardiovascular Core Labs, MedStar Health Research Institute and Georgetown University, Washington, District of Columbia, USA
| | - Nicholas Bates
- Structural Heart Clinical Affairs, Abbott Medical, St. Paul, Minnesota, USA
| | - Gregory P. Fontana
- Cardiovascular Institute, Hospital Corporation of America, Los Robles Regional Medical Center, Thousand Oaks, California, USA
| |
Collapse
|
8
|
Tobe A, Garg S, Möllmann H, Rück A, Kim WK, Buono A, Scotti A, Latib A, Toggweiler S, Mangieri A, Laine M, Meduri CU, Rheude T, Wong I, Pruthvi CR, Tsai TY, Onuma Y, Serruys PW. Short-Term Outcomes of ACURATE neo2. STRUCTURAL HEART : THE JOURNAL OF THE HEART TEAM 2024; 8:100277. [PMID: 38799801 PMCID: PMC11121741 DOI: 10.1016/j.shj.2023.100277] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/27/2023] [Revised: 12/02/2023] [Accepted: 12/21/2023] [Indexed: 05/29/2024]
Abstract
Inferior outcomes with ACURATE neo, a self-expanding transcatheter heart valve (THV) for the treatment of severe aortic stenosis, were mainly driven by higher rates of moderate/severe paravalvular leak (PVL). To overcome this limitation, the next-generation ACURATE neo2 features a 60% larger external sealing skirt. Data on long-term performance are limited; however, clinical evidence suggests improved short-term performance which is comparable to contemporary THVs. This report reviews data on short-term clinical and echocardiographic outcomes of ACURATE neo2. A PubMed search yielded 13 studies, including 5 single arm and 8 nonrandomized comparative studies with other THVs which reported in-hospital or 30-day clinical and echocardiographic outcomes. In-hospital or 30-day all-cause mortality was ≤3.3%, which is comparable to other contemporary THVs. The rates of postprocedural ≧moderate PVL ranged 0.6%-4.7%. In multicenter propensity-matched analyses, neo2 significantly reduced the rate of ≧moderate PVL compared to neo (3.5% vs. 11.3%, p < 0.01), whereas rates were comparable to Evolut Pro/Pro+ (Neo2: 2.0% vs. Pro/Pro+: 3.1%, p = 0.28) and SAPIEN 3 Ultra (Neo2: 0.6% vs. Ultra: 1.1%, p = 0.72). The rate of permanent pacemaker implantation with neo2 was consistently low (3.3%-8.6%) except in one study, and in propensity-matched analyses were significantly lower than Evolut Pro/Pro+ (6.7% vs. 16.7%, p < 0.01), and comparable to SAPIEN 3 Ultra (8.1% vs. 10.3%, p = 0.29). In conclusion, ACURATE neo2 showed better short-term performance by considerably reducing PVL compared to its predecessor, with short-term clinical and echocardiographic outcomes comparable to contemporary THVs.
Collapse
Affiliation(s)
- Akihiro Tobe
- Department of Cardiology, University of Galway, Galway, Ireland
| | - Scot Garg
- Department of Cardiology, Royal Blackburn Hospital, Blackburn, UK
| | - Helge Möllmann
- Department of Cardiology, St. Johannes Hospital, Dortmund, Germany
| | - Andreas Rück
- Department of Cardiology, Karolinska University Hospital, Stockholm, Sweden
| | - Won-Keun Kim
- Department of Cardiology, Kerckhoff Heart and Thorax Center, Bad Nauheim, Germany
| | - Andrea Buono
- Cardiovascular Department, Interventional Cardiology Unit, Fondazione Poliambulanza Institute, Brescia, Italy
| | - Andrea Scotti
- Montefiore-Einstein Center for Heart and Vascular Care, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, New York, USA
| | - Azeem Latib
- Montefiore-Einstein Center for Heart and Vascular Care, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, New York, USA
| | | | - Antonio Mangieri
- Cardio Center, IRCCS Humanitas Research Hospital, Rozzano, Milan, Italy
| | - Mika Laine
- Department of Cardiology, Heart and Lung Center, Helsinki University and Helsinki University Central Hospital, Helsinki, Finland
| | | | - Tobias Rheude
- Department of Cardiovascular Diseases, German Heart Center Munich, Technical University Munich, Munich, Germany
| | - Ivan Wong
- Division of Cardiology, Queen Elizabeth Hospital, Kowloon, Hong Kong
| | | | - Tsung-Ying Tsai
- Department of Cardiology, University of Galway, Galway, Ireland
- Cardiovascular Center, Taichung Veterans General Hospital, Taichung, Taiwan
| | - Yoshinobu Onuma
- Department of Cardiology, University of Galway, Galway, Ireland
| | | |
Collapse
|
9
|
Kim WK, Möllmann H, Montorfano M, Ellert-Gregersen J, Rudolph TK, Van Mieghem NM, Hilker M, Amat-Santos I, Terkelsen CJ, Petronio AS, Stella P, Götberg M, Rück A, Kasel AM, Trillo R, Appleby C, Barbanti M, Blanke P, Asch FM, Modolo R, Allocco DJ, Tamburino C. Outcomes and performance of the ACURATE neo2 transcatheter heart valve in clinical practice: one-yearresults of the ACURATE neo2 PMCF Study. EUROINTERVENTION 2024; 20:85-94. [PMID: 37982152 PMCID: PMC10756225 DOI: 10.4244/eij-d-23-00823] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Accepted: 10/23/2023] [Indexed: 11/21/2023]
Abstract
BACKGROUND Transcatheter aortic valve implantation is an effective treatment for patients with aortic stenosis; however, complications related to paravalvular leakage (PVL) persist, including increased risk of mortality, cardiovascular mortality, and rehospitalisation. AIMS We sought to evaluate the clinical outcomes and valve performance at 1 year in patients with severe aortic stenosis treated with the ACURATE neo2 valve in a post-market clinical setting. METHODS Valve Academic Research Consortium-2 safety events were assessed up to 1 year. Independent core laboratories evaluated echocardiographic measures of valve performance and hypoattenuated leaflet thickening (HALT; as measured by four-dimensional computed tomography). RESULTS The study enrolled 250 patients (64% female; mean age: 81 years; baseline Society of Thoracic Surgeons risk score: 2.9±2.0%); 246 patients were implanted with ACURATE neo2. All-cause mortality was 0.8% at 30 days and 5.1% at 1 year. The 1-year rates for stroke and disabling stroke were 3.0% and 1.3%, respectively. Overall, HALT of >50% leaflet involvement of at least one leaflet was present in 9% of patients at 30 days and in 12% of patients at 1 year. No association was observed between the presence of HALT and 1-year clinical or haemodynamic outcomes. Early haemodynamic improvements were maintained up to 1 year (mean aortic valve gradient: 47.6±14.5 mmHg at baseline, 7.6±3.2 mmHg at 1 year; mean aortic valve area: 0.7±0.2 cm2 at baseline, 1.7±0.4 cm2 at 1 year). At 1 year, 99% of patients had mild or no/trace PVL (<1% had moderate PVL; no patient had severe PVL). CONCLUSIONS The study outcomes confirm favourable performance and safety up to 1 year in patients treated with ACURATE neo2 in routine clinical practice. (ClinicalTrials.gov: NCT04655248).
Collapse
Affiliation(s)
| | | | - Matteo Montorfano
- School of Medicine, Vita-Salute San Raffaele University, Milan, Italy and Interventional Cardiology Unit, IRCCS San Raffaele Scientific Institute, Milan, Italy
| | | | - Tanja K Rudolph
- Heart and Diabetes Center North Rhine-Westphalia, Bad Oeynhausen, Germany
| | | | | | | | | | | | - Pieter Stella
- University Medical Center Utrecht, Utrecht, the Netherlands
| | - Matthias Götberg
- Department of Cardiology, Skåne University Hospital, Lund University, Lund, Sweden
| | - Andreas Rück
- Department of Cardiology, Karolinska University Hospital, Stockholm, Sweden
| | | | - Ramiro Trillo
- Complejo Hospitalario Universitario de Santiago, Santiago de Compostela, Spain and Centro de Investigación Biomedica en Red Enfermedades Cardiovasculares (CIBERCV), Madrid, Spain
| | - Clare Appleby
- Liverpool Heart and Chest Hospital, Liverpool, United Kingdom
| | | | - Philipp Blanke
- Department of Radiology, St Paul's Hospital & University of British Columbia, Vancouver, BC, Canada
| | | | | | | | - Corrado Tamburino
- Division of Cardiology, Azienda Ospedaliero Universitaria Policlinico G. Rodoloco-San Marco, Catania, Italy
| |
Collapse
|
10
|
McInerney A, Bagur R. Hypoattenuated Leaflet Thickening After Transcatheter Aortic Valve Implantation: The Research Around HALT Does Not Halt. Am J Cardiol 2023; 201:378-381. [PMID: 37468396 DOI: 10.1016/j.amjcard.2023.06.061] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/06/2023] [Accepted: 06/14/2023] [Indexed: 07/21/2023]
Affiliation(s)
- Angela McInerney
- Galway University Hospital, National University of Ireland Galway, Galway, Ireland
| | - Rodrigo Bagur
- London Health Sciences Centre, Western University, London, Ontario, Canada.
| |
Collapse
|
11
|
Sinning JM. ACURATE neo2: jack of all trades or master of none? EUROINTERVENTION 2023; 19:18-19. [PMID: 37170564 PMCID: PMC10173748 DOI: 10.4244/eij-e-23-00012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Affiliation(s)
- Jan-Malte Sinning
- Department of Cardiology, St. Vincent Hospital Cologne, Cologne, Germany
| |
Collapse
|