1
|
Yu Z, Li Y, Deng L, Luo B, Wu P, Geng D. A high-performance cell-phone based polarized microscope for malaria diagnosis. JOURNAL OF BIOPHOTONICS 2023; 16:e202200290. [PMID: 36541739 DOI: 10.1002/jbio.202200290] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/20/2022] [Revised: 11/09/2022] [Accepted: 12/08/2022] [Indexed: 05/17/2023]
Abstract
We present a cell-phone based polarized microscope for diagnosing malaria through hemozoin recognition over a wide field-of-view (FOV) accompanied with decent image performance. The system is constructed based on attachment method using a lens assembly as objective, two mobile phones and two linear polarizers. A ~0.92 μm resolution across a FOV of ~3.27 mm × 3.27 mm with high imaging quality is realized, demonstrating an increased resolving power, four times improvement in FOV and better imaging quality over mobile-optical-polarization imaging device. Importantly, we also demonstrate it has capability of recognizing hemozoin within the sample for malaria diagnosis by imaging malaria-infected blood samples with similar sensitivity comparable to Leica microscopy. It is more compact, portable, and insensitive to alignment, making it highly suitable for malaria detection in a portable, easy to setup and use way in low-resource areas.
Collapse
Affiliation(s)
- Zhenfang Yu
- Analysis and Test Center of Sichuan Province, Chengdu, China
- Scientific Equipments Company of Sichuan Province, Chengdu, China
| | - Yunfei Li
- Analysis and Test Center of Sichuan Province, Chengdu, China
- Scientific Equipments Company of Sichuan Province, Chengdu, China
| | - Lin Deng
- Analysis and Test Center of Sichuan Province, Chengdu, China
| | - Bing Luo
- Analysis and Test Center of Sichuan Province, Chengdu, China
| | - Pinghui Wu
- College of Physics & Information Engineering, Quanzhou Normal University, QuanZhou, China
| | - Dongxian Geng
- Analysis and Test Center of Sichuan Province, Chengdu, China
- Scientific Equipments Company of Sichuan Province, Chengdu, China
| |
Collapse
|
2
|
Liu L, An X, Zhang H, Lu Z, Nie S, Cao H, Xu Q, Liu H. Ball milling pretreatment facilitating α-amylase hydrolysis for production of starch-based bio-latex with high performance. Carbohydr Polym 2020; 242:116384. [PMID: 32564822 DOI: 10.1016/j.carbpol.2020.116384] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2020] [Accepted: 04/27/2020] [Indexed: 11/28/2022]
Abstract
Starch based bio-latex has been widely researched in the coating paper area for the purpose of partial replacement of petroleum-based binders. In this paper, a green and facile ball milling pretreatment was proposed to modify the starch granules before α-amylase hydrolysis by breaking up their crystalline structure, thus improving the accessibility and susceptibility of amylase into starch structure. It was found that the improved hydrolysis process after 8 h ball milling can generate suitable degree of polymerization of polysaccharides or oligosaccharides, which further facilitated the following H2O2 oxidation and SHMP crosslinking processes. In addition, a mechanism was also demonstrated to illustrate the improvement induced by ball milling pretreatment. The prepared bio-latex with crosslinking-structure performed excellent adhesive properties when substituted 25 % of petroleum-based latex during paper coating application, which showed great potential in improving the economic, cost, and environment benefits of traditional production of coated paper.
Collapse
Affiliation(s)
- Liqin Liu
- Tianjin Key Laboratory of Pulp and Paper, Tianjin University of Science and Technology, No. 29, 13th Street, TEDA, Tianjin, 300457, PR China
| | - Xingye An
- Tianjin Key Laboratory of Pulp and Paper, Tianjin University of Science and Technology, No. 29, 13th Street, TEDA, Tianjin, 300457, PR China.
| | - Hao Zhang
- Tianjin Key Laboratory of Pulp and Paper, Tianjin University of Science and Technology, No. 29, 13th Street, TEDA, Tianjin, 300457, PR China
| | - Zonghong Lu
- Tianjin Key Laboratory of Pulp and Paper, Tianjin University of Science and Technology, No. 29, 13th Street, TEDA, Tianjin, 300457, PR China
| | - Shuangxi Nie
- Guangxi Key Laboratory of Clean Pulp & Papermaking and Pollution Control, College of Light Industry and Food Engineering, Guangxi University, Nanning 530004, PR China
| | - Haibing Cao
- Zhejiang Jing Xing Paper Joint Stock Co., Ltd., No. 1, Jingxing Industry Zone, Jingxing First Road, Caoqiao Street, Pinghu, Zhejiang Province, 314214, PR China
| | - Qingliang Xu
- Zhejiang Jing Xing Paper Joint Stock Co., Ltd., No. 1, Jingxing Industry Zone, Jingxing First Road, Caoqiao Street, Pinghu, Zhejiang Province, 314214, PR China
| | - Hongbin Liu
- Tianjin Key Laboratory of Pulp and Paper, Tianjin University of Science and Technology, No. 29, 13th Street, TEDA, Tianjin, 300457, PR China.
| |
Collapse
|
3
|
Pirnstill CW, Coté GL. Malaria Diagnosis Using a Mobile Phone Polarized Microscope. Sci Rep 2015; 5:13368. [PMID: 26303238 PMCID: PMC4548194 DOI: 10.1038/srep13368] [Citation(s) in RCA: 78] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2015] [Accepted: 07/14/2015] [Indexed: 12/15/2022] Open
Abstract
Malaria remains a major global health burden, and new methods for low-cost, high-sensitivity, diagnosis are essential, particularly in remote areas with low-resource around the world. In this paper, a cost effective, optical cell-phone based transmission polarized light microscope system is presented for imaging the malaria pigment known as hemozoin. It can be difficult to determine the presence of the pigment from background and other artifacts, even for skilled microscopy technicians. The pigment is much easier to observe using polarized light microscopy. However, implementation of polarized light microscopy lacks widespread adoption because the existing commercial devices have complicated designs, require sophisticated maintenance, tend to be bulky, can be expensive, and would require re-training for existing microscopy technicians. To this end, a high fidelity and high optical resolution cell-phone based polarized light microscopy system is presented which is comparable to larger bench-top polarized microscopy systems but at much lower cost and complexity. The detection of malaria in fixed and stained blood smears is presented using both, a conventional polarized microscope and our cell-phone based system. The cell-phone based polarimetric microscopy design shows the potential to have both the resolution and specificity to detect malaria in a low-cost, easy-to-use, modular platform.
Collapse
Affiliation(s)
- Casey W Pirnstill
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843
| | - Gerard L Coté
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843.,Center for Remote Health Technologies and Systems, Texas Engineering Experiment Station, College Station, TX 77843
| |
Collapse
|