Oliveira IV, Oliveira LVSX, Santos VMB, Souza JLT, Costa MLL, Borges PF, Campos DB, Talieri IC. Determination of intraocular pressure and Schirmer tear test and the comparison between the applanation tonometer (Tono-Pen AVIA®) and the rebound tonometer (TonoVet Plus®) in mini lionhead rabbits.
Vet Ophthalmol 2024;
27:53-60. [PMID:
37747053 DOI:
10.1111/vop.13150]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2023] [Revised: 09/13/2023] [Accepted: 09/13/2023] [Indexed: 09/26/2023]
Abstract
OBJECTIVE
To determine intraocular pressure (IOP) and tear production, as well as to compare the IOP obtained with the TonoVet Plus® (rebound) with the Tono-Pen Avia® (applanation) tonometers.
ANIMALS
Twenty-five Mini Lionhead rabbits (n = 50 eyes).
PROCEDURE
Tear production was measured at 6:00 a.m. and 6:00 p.m. by using the STT. The IOP reading was performed with the rebound tonometer, followed by the applanation tonometer, at 6:00 a.m., 9:00 a.m., 12:00 p.m., 3:00 p.m., and 6:00 p.m. Regression analysis, analysis of variance (anova) and Bland-Altman statistics were used.
RESULTS
Daily tear production was 10.25 ± 3.75 mm/min, with no differences among the moments evaluated. Average daily IOP was 17.7 ± 3.08 mmHg with the TonoVet Plus® and 11.5 ± 4.56 mmHg with the Tono-Pen Avia®. IOP values were higher at the beginning and end of the day with both tonometers.
CONCLUSION
The IOP values are higher with the TonoVet Plus® tonometer. The reference values of IOP and tear production obtained in this work may support the diagnosis, treatment, and monitoring of ocular disorders in pet Mini Lionhead rabbits.
Collapse