Karunakar P, Reddy MSR, Faizuddin U, Priya PS, Karteek BS, Saideep CV. Comparative evaluation of working length determined using integrated apex locator and root ZX mini under various irrigating solutions: An
in vivo study.
JOURNAL OF CONSERVATIVE DENTISTRY AND ENDODONTICS 2023;
26:590-594. [PMID:
38292354 PMCID:
PMC10823966 DOI:
10.4103/jcde.jcde_68_23]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/07/2023] [Revised: 08/08/2023] [Accepted: 08/10/2023] [Indexed: 02/01/2024]
Abstract
Background
Electronic apex locators (EALs) are frequently used as adjuvant to radiographs in working length (WL) determination. The introduction of integrated apex locators (IALs) further simplified the root canal treatment by continuous monitoring of the apex while root canal shaping.
Aim
The aim of this study was to evaluate the efficacy of radiographs, EAL, and IAL in determining the WL in the presence of various irrigants.
Materials and Methods
The present in vivo study was carried out on 30 patients who were divided into 10 in each group, based on the type of irrigant used; 0.9% saline (Group 1), 0.2% chlorhexidine (Group 2), and 2.5% of sodium hypochlorite (NaOCL) (Group 3). In each group, WL is determined using conventional radiographs, Root ZX Mini (EAL), and CanalPro CL2i (IAL).
Statistical Analysis
Kruskal-Wallis test and Friedman's two-way ANOVA test were used for statistical analysis.
Results
Mean WL was comparably lower with Root ZX Mini, while the WL by CanalPro CL2i and the radiographic method were comparable. In all methods, the type of solutions used did not influence the WL, with a higher mean WL when NaOCL is used as an irrigant. Nevertheless, the above comparisons were not statistically significant.
Conclusion
the irrigation solutions employed in this study had no impact on the performance of apex locators and radiographs.
Collapse