1
|
Alharbi G, Al Nahedh HNA, Al-Saud LM, Shono N, Maawadh A. Flexural strength and degree of conversion of universal single shade resin-based composites. Heliyon 2024; 10:e32557. [PMID: 38961985 PMCID: PMC11219500 DOI: 10.1016/j.heliyon.2024.e32557] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2023] [Revised: 05/13/2024] [Accepted: 06/05/2024] [Indexed: 07/05/2024] Open
Abstract
Background/purpose Recently, a group of universal single-shade resin-based composites (RBCs) has been developed to simplify the process of shade selection. Excellent mechanical and physical properties are crucial for the ultimate success and clinical longevity of restorations. Therefore, evaluating the properties of the single-shaded RBCs is imperative. This study aimed to determine the flexural strength (FS) and degree of conversion (DC) of universal single-shade RBCs. Materials and methods In this study, four commercial RBCs were used; three universal single-shade RBCs; Omnichroma (OC), Charisma® Diamond ONE (CD), and Vittra APS Unique (VU), and a conventional nanohybrid composite Filtek™ Z250 XT (FT) which was used as a control. Sixty composite beams and 40 composite discs were used for FS and DC, respectively. A universal test machine with a three-point bending test was used to measure the FS, whereas the DC was measured using a Fourier-transform infrared spectrometer (FTIR). Three fractured specimens from each resin composite group were qualitatively analyzed using scanning electron microscopy. Results ANOVA was used to compare the mean values of FS and DC among the four RBCs (OC, CD, VU, and FT). Highly significant differences were observed in the mean FS and DC values (F = 673.043, p < 0.001 and F (=782.4, p < 0.0001), respectively. The highest FS was observed in the CD group, followed by FT and VU groups; the lowest value was observed in the OC group. In addition, a statistically significant difference was identified in DC values. The highest DC value was observed in VU, followed by OC and CD, and the lowest DC value was observed in FT. Conclusion Universal single-shade RBCs demonstrated a good FS, except for OC, which exhibited a significantly low FS. The DC of the universal single-shade RBCs was higher than that of the conventional nanohybrid composite restorative material.
Collapse
Affiliation(s)
- Ghada Alharbi
- Department of Restorative Dental Science, College of Dentistry, King Saud University. P.O. Box 60169, Riyadh 11545, Saudi Arabia
- Department of Clinical Dental Sciences, College of Dentistry, Princess Nourah Bint Abdulrahman University. PO Box 84428, Riyadh 11671, Saudi Arabia
| | - Hend NA Al Nahedh
- Department of Restorative Dental Science, College of Dentistry, King Saud University. P.O. Box 60169, Riyadh 11545, Saudi Arabia
| | - Loulwa M. Al-Saud
- Department of Restorative Dental Science, College of Dentistry, King Saud University. P.O. Box 60169, Riyadh 11545, Saudi Arabia
| | - Nourah Shono
- Department of Restorative Dental Science, College of Dentistry, King Saud University. P.O. Box 60169, Riyadh 11545, Saudi Arabia
| | - Ahmed Maawadh
- Department of Restorative Dental Science, College of Dentistry, King Saud University. P.O. Box 60169, Riyadh 11545, Saudi Arabia
| |
Collapse
|
2
|
Alharbi G, Al Nahedh HN, Al-Saud LM, Shono N, Maawadh A. Effect of different finishing and polishing systems on surface properties of universal single shade resin-based composites. BMC Oral Health 2024; 24:197. [PMID: 38326838 PMCID: PMC10848531 DOI: 10.1186/s12903-024-03958-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2023] [Accepted: 01/30/2024] [Indexed: 02/09/2024] Open
Abstract
BACKGROUND Recently, universal single-shade resin composites have become increasingly available in the dental market. The modification of their composition can have an inadvertent effect on their physical and surface properties, and subsequently determinantal effect on their clinical function and longevity. Therefore, this study aimed to evaluate the effect of different finishing and polishing (F/P) systems on surface roughness (Ra), surface gloss (GU), and Vickers microhardness (VMH) of universal single-shade RBCs. MATERIALS AND METHODS Four commercial RBCs were used; the universal single-shade RBCs were Omnichroma, Charisma® Diamond ONE, and Vittra APS Unique, and a conventional nanocomposite Filtek™ Z250 XT was used as a control. The 3 F/P systems were Sof-Lex™ XT, Enhance®/PoGo®, and Diacomp® Plus Twist. A total of 160 discs were used for the 3 F/P system groups for all RBCs (n = 10). After F/P, the Ra, GU, and VMH were assessed. The data were analyzed using 2-way ANOVA at p-value < 0.05. RESULTS Significant differences were found among the four RBCs and the 3 F/P systems (p < .000). Omnichroma showed the lowest Ra and acceptable GU, but the lowest VMH. Charisma showed the highest Ra, acceptable GU, and VMH. Vittra showed acceptable Ra, GU, and VMH and Filtek showed the highest GU, VMH, and acceptable Ra. CONCLUSION Although conventional nanohybrid RBC (Filtek Z250 XT) showed better GU and VMH values, the universal single-shade RBCs demonstrated comparable surface properties. The highest GU & VMH and lowest Ra were achieved by Diacomp followed by Enhance and Soflex.
Collapse
Affiliation(s)
- Ghada Alharbi
- Department of Restorative Dental Science, College of Dentistry, King Saud University, P.O. Box 60169, Riyadh, 11545, Saudi Arabia.
- Department of Clinical Dental Sciences, College of Dentistry, Princess Nourah bint Abdulrahman University, Box 84428, Riyadh, PO, 11671, Saudi Arabia.
| | - Hend Na Al Nahedh
- Department of Restorative Dental Science, College of Dentistry, King Saud University, P.O. Box 60169, Riyadh, 11545, Saudi Arabia
| | - Loulwa M Al-Saud
- Department of Restorative Dental Science, College of Dentistry, King Saud University, P.O. Box 60169, Riyadh, 11545, Saudi Arabia
| | - Nourah Shono
- Department of Restorative Dental Science, College of Dentistry, King Saud University, P.O. Box 60169, Riyadh, 11545, Saudi Arabia
| | - Ahmed Maawadh
- Department of Restorative Dental Science, College of Dentistry, King Saud University, P.O. Box 60169, Riyadh, 11545, Saudi Arabia
| |
Collapse
|
3
|
Kedici Alp C, Arslandaş Dinçtürk B, Altınışık H. The Effect of Food-Simulating Liquids on Surface Features of Single-Shade Universal Composites: An In Vitro Study. J Int Soc Prev Community Dent 2023; 13:157-165. [PMID: 37223442 PMCID: PMC10202257 DOI: 10.4103/jispcd.jispcd_233_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2022] [Revised: 03/14/2023] [Accepted: 03/26/2023] [Indexed: 05/25/2023] Open
Abstract
Objectives This study aimed to investigate the microhardness, surface roughness, and field emission scanning electron microscopes (FE-SEM) images of three different single-shade composites (Essentia Universal, Omnichroma, and Vittra APS Unique) in food simulation liquids such as ethanol, citric acid, and distilled water. Materials and Methods Three single-shade universal composites were selected for this study. For each composite resin group, 92 samples (5-mm diameter and 2-mm depth) were prepared in plexiglass molds (N = 276). Then, samples were separated into four groups randomly consisting of 23 samples each (10 for hardness, 10 for roughness, and 3 for FE-SEM analysis). Three groups were immersed in food-simulating liquids (FSL)-citric acid (0.02N), distilled water, and 75% ethanol stored in a glass at 37°C for the next 7 days to simulate a wet oral environment. Control samples were stored in an opaque-light-proof box at room temperature. After the conditioning period, roughness and microhardness were measured, and FE-SEM analysis was performed. For statistical analysis, the two-way analysis of variance and Tukey honestly significant difference tests were used to evaluate roughness and microhardness (P < 0.05). Results There was a statistically significant difference between the composites in terms of roughness and hardness averages (P = 0.001; P < 0.05). Omnichroma showed the most surface changes in ethanol storage, whereas Vittra Unique showed the most surface changes in citric acid storage such as Essentia. Conclusion FSL that mimic various oral environments affect single-shade universal resin composite restorations.
Collapse
Affiliation(s)
- Cemile Kedici Alp
- Department of Restorative Dentistry, Faculty of Dentistry, Gazi University, Ankara, Turkey
| | | | - Hanife Altınışık
- Department of Restorative Dentistry, Faculty of Dentistry, Gazi University, Ankara, Turkey
| |
Collapse
|
4
|
Altınışık H, Özyurt E. Instrumental and visual evaluation of the color adjustment potential of different single-shade resin composites to human teeth of various shades. Clin Oral Investig 2023; 27:889-896. [PMID: 36222960 DOI: 10.1007/s00784-022-04737-x] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2022] [Accepted: 10/04/2022] [Indexed: 01/08/2024]
Abstract
OBJECTIVE The study aims to evaluate the color adjustment potential (CAP-I, CAP-V) of different single-shade resin composites. MATERIALS AND METHODS The shades of 40 human incisors were determined using a spectrophotometer, with the teeth divided into four groups of the same shade (n = 10). The following single-shade resin composites were tested: Omnichroma, Charisma Diamond One, Vittra Unique, and Essentia Universal. The specimens were prepared as "dual" and "single." Standardized cavity preparations (diameter, 7 mm; depth, 2 mm) were prepared in human incisor teeth and then restored for dual specimens. Composite duplicates of human incisors were prepared with resin composites for single specimens (n = 10). The color match of these specimens to that of unrestored human incisors was compared, and the color difference (ΔE*) was calculated. Independent observers conducted a visual evaluation of the specimens and scored them. CAP-I and CAP-V values were determined. A one-way analysis of variance test was used for statistical analysis (p < 0.05). RESULTS There was no statistically significant difference between the CAP-V and CAP-I values of the tested single-shade resin composites (p > 0.05). All the materials tested had acceptable color-matching potential. CONCLUSIONS In terms of color matching, there were no significant differences between the different tooth shades of all the tested resin composites. CLINICAL RELEVANCE Single-shade resin composites have acceptable CAP. The use of single-shade resin composites can reduce in-chair clinical times by minimizing the time spent on shade selection.
Collapse
Affiliation(s)
- Hanife Altınışık
- Department of Restorative Dentistry, Faculty of Dentistry, Gazi University, Ankara, Turkey
| | - Esra Özyurt
- Department of Restorative Dentistry, Faculty of Dentistry, Trakya University, Edirne, Turkey.
| |
Collapse
|
5
|
Yılmaz Atalı P, Doğu Kaya B, Manav Özen A, Tarçın B, Şenol AA, Tüter Bayraktar E, Korkut B, Bilgin Göçmen G, Tağtekin D, Türkmen C. Assessment of Micro-Hardness, Degree of Conversion, and Flexural Strength for Single-Shade Universal Resin Composites. Polymers (Basel) 2022; 14:polym14224987. [PMID: 36433113 PMCID: PMC9697557 DOI: 10.3390/polym14224987] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2022] [Revised: 11/12/2022] [Accepted: 11/14/2022] [Indexed: 11/19/2022] Open
Abstract
Single-shade universal resin composites (SsURC) are preferred in clinical practice to reduce time for shade selection and obtain good esthetic results. In this study, the static mechanical properties of seven new SsURCs were investigated, their spectral analyzes were performed and scanning electron microscopy (SEM) evaluations were presented. Charisma Diamond One/DO, Admira Fusion x-tra/AFX, Omnichroma/OC, OptiShade/OS, Essentia Universal/EU, Zenchroma/ZC, Vittra APS Unique/VU were used in a three-point bending test to determine flexural strength (FS) and elastic modulus (EM); Vickers micro-hardness (VHN) and hardness-ratio (HR) were performed with a micro-hardness tester from top/bottom after 24-h/15-days of storage in distilled water at 37 °C (±1 °C). The degree of conversion (DC) was assessed by using Fourier transform infrared spectroscopy (FTIR). The structure of the resin matrix and filler content were assessed by SEM. Data were analyzed using IBM SPSS V23 and the R program and the significance level was taken as p < 0.05. The main effect of the tested SsURCs was found to be statistically significant on FS, EM, VHN, and DC values (p < 0.001). Bis-GMA free SsURCs (AFX, DO, VU) showed better DC and HR except for OC. All seven tested SsURCs conform to the requirements of ISO standards for dental resin composites for all tested categories.
Collapse
|
6
|
Effect of Chemical Challenges on the Properties of Composite Resins. Int J Dent 2021; 2021:4895846. [PMID: 34899913 PMCID: PMC8654529 DOI: 10.1155/2021/4895846] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2021] [Revised: 10/31/2021] [Accepted: 11/19/2021] [Indexed: 11/24/2022] Open
Abstract
Objective To evaluate the chemical degradation effect on microhardness and roughness of composite resins after aging. Materials and Methods Specimens (n = 10) were used for Filtek Z350 XT (Z350), Filtek Bulk Fill (BULK), Micerium HRI (HRI), Micerium BIOFUNCION (BIO), and Vittra APS (VITTRA). Microhardness and roughness were performed before and after degradation with the followed solutions: citric acid, phosphoric acid, 75% alcohol, and distilled water. Samples were to a 180-day chemical cycling protocol. After degradation, one sample of each group was selected for scanning electron microscope evaluation. The data were analyzed with normal distribution (Kolmogorov–Smirnov) and similarities of variations for the Bartlett test. ANOVA (two-way) followed by Tukey's test was performed considering treatment and composite resin (P < 0.05). Results For microhardness and roughness, variations were noted to different solution and resin formulations. Z350 and HRI showed higher microhardness percentage loss, and it was more evident after storage in alcohol (−48.49 ± 20.16 and −25.02 ± 14.04, respectively) and citric acid (−65.05 ± 28.97 and 16.12 ± 8.35, respectively). For roughness, Z350 and VITTRA showed less delta values after alcohol storage (−0.047 ± 0.007 and −0.022 ± 0.009, respectively). HRI had the worst roughness for citric acid (−0.090 ± 0.025). All resins were not statistically different between each other in water and phosphoric acid. Conclusion The formulations of restorative resin materials influenced in degree of surface degradation after 180 days of chemical degradation. Water was considered the solution that causes less degradation for microhardness and roughness evaluations. For microhardness, alcohol was considered the worst solution for Z350 and HRI. For superficial roughness, Z350 and VITTRA showed less degradation in alcohol and citric and phosphoric acid solutions.
Collapse
|