Ludes G, Ohana M, Labani A, Meyer N, Moliére S, Roy C. Impact of a reduced iodine load with deep learning reconstruction on abdominal MDCT. Medicine (Baltimore) 2023; 102:e34579. [PMID: 37657067 PMCID: PMC10476859 DOI: 10.1097/md.0000000000034579] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Accepted: 07/13/2023] [Indexed: 09/03/2023] Open
Abstract
To evaluate the impact of a reduced iodine load using deep learning reconstruction (DLR) on the hepatic parenchyma compared to conventional iterative reconstruction (hybrid IR) and its consequence on the radiation dose and image quality. This retrospective monocentric intraindividual comparison study included 66 patients explored at the portal phase using different multidetector computed tomography parameters: Group A, hybrid IR algorithm (hybrid IR) and a nonionic low-osmolality contrast agent (350 mgI/mL); Group B, DLR algorithm (DLR) and a nonionic iso-osmolality contrast agent (270 mgI/mL). We recorded the attenuation of the liver parenchyma, image quality, and radiation dose parameters. The mean hounsfield units (HU) value of the liver parenchyma was significantly lower in group B, at 105.9 ± 10.9 HU versus 118.5 ± 14.6 HU in group A. However, the 90%IC of mean liver attenuation in the group B (DLR) was between 100.8 HU and 109.3 HU. The signal-to-noise ratio of the liver parenchyma was significantly higher on DLR images, increasing by 56%. However, for both the contrast-to-noise ratio (CNR) and CNR liver/PV no statistical difference was found, even if the CNR liver/PV ratio was slightly higher for group A. The mean dose-length product and computed tomography dose index volume values were significantly lower with DLR, corresponding to a radiation dose reduction of 36% for the DLR. Using a DLR algorithm for abdominal multidetector computed tomography with a low iodine load can provide sufficient enhancement of the liver parenchyma up to 100 HU in addition to the advantages of a higher image quality, a better signal-to-noise ratio and a lower radiation dose.
Collapse
Affiliation(s)
- Gaspard Ludes
- Department of Radiology B, University Hospital of Strasbourg – New Civil Hospital, Strasbourg, Cedex, France
| | - Mickael Ohana
- Department of Radiology B, University Hospital of Strasbourg – New Civil Hospital, Strasbourg, Cedex, France
| | - Aissam Labani
- Department of Radiology B, University Hospital of Strasbourg – New Civil Hospital, Strasbourg, Cedex, France
| | - Nicolas Meyer
- Department of Statistics, University Hospital of Strasbourg – New Civil Hospital, Strasbourg, Cedex, France
| | - Sébastien Moliére
- Department of Radiology B, University Hospital of Strasbourg – New Civil Hospital, Strasbourg, Cedex, France
| | - Catherine Roy
- Department of Radiology B, University Hospital of Strasbourg – New Civil Hospital, Strasbourg, Cedex, France
| |
Collapse
|
2
|
Chen L, Ge S, Chen Y, Zhang TT, Zhu ZH. A feasibility study of 70 kV double low-dose coronary imaging technique in abdomen-fatty patients using dual-source CT. Afr Health Sci 2023; 23:599-606. [PMID: 38357100 PMCID: PMC10862595 DOI: 10.4314/ahs.v23i3.70] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/16/2024] Open
Abstract
Objective To investigate the aplication of low contrast agent concentration and low tube voltage in coronary CTA on patients with high BMI (26kg/m228kg/m2). Methods 60 patients with high BMI (26kg/m228kg/m2) were randomly divided into two groups: double low group A (n=30, tube voltage = 70 KV), double low group B (n=30, tube voltage = 70 KV), processed by SAFIRE iterative reconstruction with 270 mgI/ml contrast agent. Conventional group a (n=30, tube voltage = 120 KV), conventional group b (n=30, tube voltage = 120 KV), with filtered back projection (FBP) and 370 mg I/ml contrast agent. the image excellent index (FOM), the effective radiation dose (ED), mean CT value, signal-to-noise ratio (SNR), and contrast-to-noise ratio(CNR) between corresponding groups were compared. Result There was no significant difference in subjective scores of coronary artery image quality between the two high BMI subgroups (P>0.05).The ED of group A (1.103±0.101 mSv) was significantly lower than that of group a (4.663±0.412 mSv) (P<0.001).There was no significant difference in mean CT value, SNR and CNR between the two subgroups (P>0.05).The image excellent index (FOM) of group A was higher than that of group a (P<0.05).The total iodine content and iodine injection rate in group A were lower than those in group a (P<0.001).The difference of subjective scores of coronary artery image quality between the two ultra-high subgroups was significant. The mean CT value, SNR and CNR of group B were lower than those of group b (P<0.05). The images of 14 patients in group B could not meet the diagnosis demand. Conclusion It is feasible to reduce the tube voltage to 70KV in patients with abdominal BMI with high BMI (26Kg/m228Kg/m2), under the same conditions, the 70KV can not meet the daily diagnosis requirement.
Collapse
Affiliation(s)
- Lei Chen
- Department of Radiology, The Affiliated Huaian No.1 People's Hospital of Nanjing Medical University, Huaian 223300, China
| | - Shang Ge
- Department of Radiology, The Affiliated Huaian No.1 People's Hospital of Nanjing Medical University, Huaian 223300, China
| | - Yuan Chen
- Department of Radiology, The Affiliated Huaian No.1 People's Hospital of Nanjing Medical University, Huaian 223300, China
| | - Ting-Ting Zhang
- Department of Radiology, The Affiliated Huaian No.1 People's Hospital of Nanjing Medical University, Huaian 223300, China
| | - Zhao-Huan Zhu
- Department of Radiology, The Affiliated Huaian No.1 People's Hospital of Nanjing Medical University, Huaian 223300, China
| |
Collapse
|
3
|
The Image Quality and Diagnostic Performance of CT with Low-Concentration Iodine Contrast (240 mg Iodine/mL) for the Abdominal Organs. Diagnostics (Basel) 2022; 12:diagnostics12030752. [PMID: 35328304 PMCID: PMC8947528 DOI: 10.3390/diagnostics12030752] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2022] [Revised: 03/11/2022] [Accepted: 03/17/2022] [Indexed: 11/17/2022] Open
Abstract
Purpose: To evaluate the difference between CT examinations using 240 mgI/mL contrast material (CM) and 320 mgI/mL CM in the contrast enhancement of the abdominal organs and the diagnostic performance for focal hepatic lesions. Materials and methods: This retrospective study included 422 CT examinations, using 240 mgI/mL iohexol (Group A, 206 examinations) and 320 mgI/mL ioversol (Group B, 216 examinations), performed between April 2019 and May 2020. Two CT scanners (single-source CT (machine A) and dual-source CT (machine B)) were used to obtain CT images. Two radiologists independently drew regions of interest (ROIs) in the liver, pancreas, spleen, kidney, aorta, portal vein, and paraspinal muscle. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated for each organ. They evaluated the degree of subjective enhancement of the organs and detected/differentiated focal hepatic lesions. Results: The SNR, CNR, and subjective enhancement of most organs were significantly higher in Group B than in Group A (p < 0.05). The sensitivity and specificity for cysts and malignancy were higher than 85.0% in both groups. The sensitivity for hemangioma was lower in Group B (<75%) than in Group A. In Group A, the SNR and CNR were significantly higher in most organs with machine B than with machine A. Conclusion: Although the SNR and CNR of the abdominal organs were lower with 240 mgI/mL CM than with 320 mgI/mL CM, 240 mgI/mL CM was feasible for evaluating the liver. A CT scanner with more advanced specifications may be beneficial for examinations with 240 mgI/mL CM by using lower tube voltage.
Collapse
|
4
|
Zanca F, Brat HG, Pujadas P, Racine D, Dufour B, Fournier D, Rizk B. Prospective multicenter study on personalized and optimized MDCT contrast protocols: results on liver enhancement. Eur Radiol 2021; 31:8236-8245. [PMID: 33914115 DOI: 10.1007/s00330-021-07953-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2021] [Revised: 03/12/2021] [Accepted: 03/26/2021] [Indexed: 01/19/2023]
Abstract
OBJECTIVE To determine a personalized and optimized contrast injection protocol for a uniform and optimal diagnostic level of liver parenchymal enhancement, in a large patient population enrolled in a multicenter study. METHODS Six hundred ninety-two patients who underwent a standardized multi-phase liver CT examination were prospectively assigned to one contrast media (CM) protocol group: G1 (100 mL fixed volume, 37 gI); G2 (600 mgI/kg of total body weight (TBW)); G3 (750 mgI/kg of fat-free mass (FFM)), and G4 (600 mgI/kg of FFM). Change in liver parenchyma CT number between unenhanced and contrast-enhanced images was measured by two radiologists, on 3-mm pre-contrast and portal phase axial reconstructions. The enhancement histograms were compared across CM protocols, specifically according to a target diagnostic value of 50 HU. The total amount of iodine dose was also compared among protocols by median and interquartile range (IQR). The Kruskal-Wallis and Mann-Whitney U tests were used to assess significant differences (p < 0.005), as appropriate. RESULTS A significant difference (p < 0.001) was found across the groups with liver enhancement decreasing from median over-enhanced values of 77.0 (G1), 71.3 (G2), and 65.1 (G3) to a target enhancement of 53.2 HU for G4. Enhancement IQR was progressively reduced from 26.5 HU (G1), 26.0 HU (G2), and 17.8 HU (G3) to 14.5 HU (G4). G4 showed a median iodine dose of 26.0 gI, significantly lower (p < 0.001) than G3 (33.9 gI), G2 (38.8 gI), and G1 (37 gI). CONCLUSIONS The 600 mgI/kg FFM-based protocol enabled a diagnostically optimized liver enhancement and improved patient-to-patient enhancement uniformity, while significantly reducing iodine load. KEY POINTS • Consistent and clinically adequate liver enhancement is observed with personalized and optimized contrast injection protocol. • Fat-free mass is an appropriate body size parameter for correlation with liver parenchymal enhancement. • Diagnostic oncology follow-up liver CT examinations may be obtained using 600 mgI/kg of FFM.
Collapse
Affiliation(s)
- F Zanca
- Palindromo Consulting, Willem de Corylaan, 51 3001, Leuven, Belgium.
| | - H G Brat
- Institut de Radiologie de Sion, Groupe 3R, Sion, Switzerland
| | | | - D Racine
- Institute of Radiation Physics (IRA), Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - B Dufour
- Institut de Radiologie de Sion, Groupe 3R, Sion, Switzerland
| | - D Fournier
- Institut de Radiologie de Sion, Groupe 3R, Sion, Switzerland
| | - B Rizk
- Centre d'Imagerie de Fribourg, Groupe 3R, Fribourg, Switzerland
| |
Collapse
|
5
|
Miyoshi K, Onoda H, Tanabe M, Nakao S, Higashi M, Iida E, Okada M, Furukawa M, Ito K. Image quality in dual-source multiphasic dynamic computed tomography of the abdomen: evaluating the effects of a low tube voltage (70 kVp) in combination with contrast dose reduction. Abdom Radiol (NY) 2020; 45:3755-3762. [PMID: 32382819 DOI: 10.1007/s00261-020-02565-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
PURPOSE To compare the image quality of multiphasic (arterial, portal, and equilibrium phases) dynamic computed tomography (CT) of the abdomen obtained by a low tube voltage (70kVp) in combination with a half-dose iodine load using low-concentration contrast agent in high tube output dual-source CT with a standard tube voltage (120kVp) and full-dose iodine load using the same group of adult patients. METHODS Fifty-five patients who underwent both low-tube-voltage (70kVp) abdominal CT with a half-dose iodine load and standard-tube-voltage (120kVp) CT with a full-dose iodine load were analyzed. The mean CT values and signal-to-noise ratio (SNR) of the liver, aorta and portal veins were quantitatively assessed. In addition, the contrast enhancement of the abdominal organs and overall image quality were qualitatively evaluated. RESULTS The mean CT values and SNR of the liver parenchyma were significantly higher in 70-kVp protocol than in 120-kVp protocol in all 3 phases (p = 0.018 ~ < 0.001). Regarding the qualitative analysis, the overall image quality in the 70-kVp protocol was significantly better than in the 120-kVp protocol in all 3 phases (p < 0.001). In addition, the contrast enhancement scores of the liver parenchyma and hepatic vein in the equilibrium phase were also significantly higher in the 70-kVp protocol than in the 120-kVp protocol (p < 0.001). CONCLUSION A low tube voltage (70kVp) in combination with a half-dose iodine load using a low-concentration contrast agent and an iterative reconstruction algorithm in high tube output dual-source CT may improve the contrast enhancement and image quality in multiphasic dynamic CT of the abdomen in patients under 71 kg of body weight.
Collapse
Affiliation(s)
- Keisuke Miyoshi
- Department of Radiology, Yamaguchi University Graduate School of Medicine, 1-1-1 Minami-Kogushi, Ube, Yamaguchi, 755-8505, Japan
| | - Hideko Onoda
- Department of Radiology, Yamaguchi University Graduate School of Medicine, 1-1-1 Minami-Kogushi, Ube, Yamaguchi, 755-8505, Japan
| | - Mashiro Tanabe
- Department of Radiology, Yamaguchi University Graduate School of Medicine, 1-1-1 Minami-Kogushi, Ube, Yamaguchi, 755-8505, Japan
| | - Sei Nakao
- Department of Radiology, Yamaguchi University Graduate School of Medicine, 1-1-1 Minami-Kogushi, Ube, Yamaguchi, 755-8505, Japan
| | - Mayumi Higashi
- Department of Radiology, Yamaguchi University Graduate School of Medicine, 1-1-1 Minami-Kogushi, Ube, Yamaguchi, 755-8505, Japan
| | - Etsushi Iida
- Department of Radiology, Yamaguchi University Graduate School of Medicine, 1-1-1 Minami-Kogushi, Ube, Yamaguchi, 755-8505, Japan
| | - Munemasa Okada
- Department of Radiology, Yamaguchi University Graduate School of Medicine, 1-1-1 Minami-Kogushi, Ube, Yamaguchi, 755-8505, Japan
| | - Matakazu Furukawa
- Department of Radiology, Yamaguchi University Graduate School of Medicine, 1-1-1 Minami-Kogushi, Ube, Yamaguchi, 755-8505, Japan
| | - Katsuyoshi Ito
- Department of Radiology, Yamaguchi University Graduate School of Medicine, 1-1-1 Minami-Kogushi, Ube, Yamaguchi, 755-8505, Japan.
| |
Collapse
|
6
|
Wang L, Gong S, Yang J, Zhou J, Xiao J, Gu J, Yang H, Zhu J, He B. CARE Dose 4D combined with sinogram-affirmed iterative reconstruction improved the image quality and reduced the radiation dose in low dose CT of the small intestine. J Appl Clin Med Phys 2019; 20:293-307. [PMID: 30508275 PMCID: PMC6333130 DOI: 10.1002/acm2.12502] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2018] [Revised: 08/06/2018] [Accepted: 10/19/2018] [Indexed: 12/27/2022] Open
Abstract
OBJECTIVE Multislice computed tomography (MSCT) has been used for diagnosis of small intestinal diseases. However, the radiation dose is a big problem. This study was to investigate whether CARE Dose 4D combined with sinogram-affirmed iterative reconstruction (SAFIRE) can provide better image quality at a lower dose for imaging small intestinal diseases compared to MSCT. METHODS The noise reduction ability of SAFIRE was assessed by scanning the plain water mold using SOMATOM Definition Flash double-source spiral CT. CT images at each stage of radiography for 239 patients were obtained. The patients were divided into groups A and B were based on different tube voltage and current or the image recombination methods. The images were restructured using with filtered back projection (FBP) and SAFIRE (S1-S5). The contrast noise ratio (CNR), CT Dose index (CTDI), subjective scoring, and objective scoring were compared to obtain the best image and reformation parameters at different stages of CT. RESULTS Twenty-six restructuring patterns of tube voltage and current were obtained by FBP and SAFIRE. The average radiation dose using CARE Dose 4D combined with SAFIRE (S4-S5) reduced approximately 74.85% compared to conditions where the tube voltage of 100 kV and tube current of 131 mAs for patients with MSCT small intestinal CT enterography at plain CT scan, arterial stage, small intestine, and portal venous phase. The objective and subjective scoring were all significantly different among groups A and B at each stage. CONCLUSIONS Combination of CARE Dose 4D and SAFIRE is shown to decrease the radiation dose while maintaining image quality.
Collapse
Affiliation(s)
- Lin Wang
- Department of RadiologyThe Second Affiliated Hospital of Nantong UniversityJiangsuChina
| | - Shenchu Gong
- Department of RadiologyThe Second Affiliated Hospital of Nantong UniversityJiangsuChina
| | - Jushun Yang
- Department of RadiologyThe Second Affiliated Hospital of Nantong UniversityJiangsuChina
| | - Jie Zhou
- Department of RadiologyThe Second Affiliated Hospital of Nantong UniversityJiangsuChina
| | - Jing Xiao
- Department of Epidemiology and Medical StatisticsSchool of Public Health Nantong UniversityNantongJiangsuChina
| | - Jin‐hua Gu
- Department of PathophysiologyNantong University Medical SchoolNantongJiangsuChina
| | - Hong Yang
- Department of RadiologyThe Second Affiliated Hospital of Nantong UniversityJiangsuChina
| | - Jianfeng Zhu
- Department of RadiologyThe Second Affiliated Hospital of Nantong UniversityJiangsuChina
| | - Bosheng He
- Department of RadiologyThe Second Affiliated Hospital of Nantong UniversityJiangsuChina
- Clinical Medicine Research Centerthe Second Affiliated Hospital of Nantong UniversityNantongJiangsuChina
| |
Collapse
|