Zhang K, Zhang S, Shi Y, Zhang L, Fu B. Effects of disinfectants on physical properties of denture base resins: A systematic review and meta-analysis.
J Prosthet Dent 2024;
131:841-858. [PMID:
35465961 DOI:
10.1016/j.prosdent.2022.03.020]
[Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2021] [Revised: 03/14/2022] [Accepted: 03/15/2022] [Indexed: 11/16/2022]
Abstract
STATEMENT OF PROBLEM
The disinfection of removable dental prostheses and orthodontic appliances is essential to preventing transmission of pathogens. However, whether different disinfection solutions and durations affect the physical properties of denture base resins is unclear.
PURPOSE
The purpose of this systematic review and meta-analysis was to statistically analyze the influence of disinfectants on the physical properties of denture base resins.
MATERIAL AND METHODS
A systematic search in Medline, Embase, PubMed, and Cochrane Library databases was conducted to evaluate the effects of chemical disinfection on the physical properties of denture base resins such as surface morphology, roughness, hardness, and flexural strength. Of 1909 studies, 44 studies were included in the systematic review and 41 in the meta-analysis. Heterogeneity was analyzed by using I2 statistics. The influence of different disinfection solutions and durations on the physical properties was further analyzed, and the risk of bias evaluated. Statistical analyses were performed by using the RevMan 5.4 software program with the standardized mean differences (SMDs) and 95% confidence intervals (CIs).
RESULTS
Of the 44 included studies, 40 studies were assessed as having a low risk of bias, and 4 had an unclear risk of bias. Meta-analysis results showed that compared with the control, disinfection could not significantly affect surface roughness and hardness within 60 minutes of immersion in disinfectant solutions or flexural strength within 30 minutes (roughness: P=.79, I2=0%; flexural strength: P=.08, I2=0%; hardness: P=.05, I2=19%). In addition, the physical properties were not significantly affected when glutaraldehyde, chlorhexidine, and peracetic acid were repeatedly used for more than 30 minutes.
CONCLUSIONS
Most of the disinfectants did not reduce the physical properties of denture base resin within 30 minutes of immersion. Glutaraldehyde, chlorhexidine, and peracetic acid are recommended if longer immersion or repeated disinfection is required.
Collapse