1
|
Lone SB, Zeeshan R, Khadim H, Khan MA, Khan AS, Asif A. Synthesis, monomer conversion, and mechanical properties of polylysine based dental composites. J Mech Behav Biomed Mater 2024; 151:106398. [PMID: 38237205 DOI: 10.1016/j.jmbbm.2024.106398] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Revised: 01/08/2024] [Accepted: 01/09/2024] [Indexed: 02/03/2024]
Abstract
OBJECTIVE The aim of this study was to synthesize a new bioactive and antibacterial composite by incorporating reactive calcium phosphate and antibacterial polylysine into a resin matrix and evaluate the effect of these fillers on structural analysis, degree of monomer conversion, mechanical properties, and bioactivity of these newly developed polypropylene based dental composites. METHODOLOGY Stock monomers were prepared by mixing urethane dimethacrylate and polypropylene glycol dimethacrylate and combined with 40 wt% silica to make experimental control (E-C). The other three experimental groups contained a fixed percentage of silica (40 wt%), monocalcium phosphate monohydrate, and β-tri calcium phosphate (5 wt% each) with varying amounts of polylysine (PL). These groups include E-CCP0 (0 wt% PL), E-CCP5 (5 wt% PL) and E-CCP10 (10 wt% PL). The commercial control used was Filtek™ Z250 3M ESPE. The degree of conversion was assessed by using Fourier transform infrared spectroscopy (FTIR). Compressive strength and Vicker's micro hardness testing were evaluated after 24 h of curing the samples. For bioactivity, prepared samples were placed in simulated body fluid for 0, 1, 7, and 28 days and were analyzed using a scanning electron microscope (SEM). SPSS 23 was used to analyze the data and one-way ANOVA and post hoc tukey's test were done, where the significant level was set ≤0.05. RESULTS Group E-C showed better mechanical properties than other experimental and commercial control groups. Group E-C showed the highest degree of conversion (72.72 ± 1.69%) followed by E-CCP0 (72.43 ± 1.47%), Z250 (72.26 ± 1.75%), E-CCP10 (71.07 ± 0.19%), and lowest value was shown by E-CCP5 (68.85 ± 7.23%). In shear bond testing the maximum value was obtained by E-C. The order in decreasing value of bond strength is E-C (8.13 ± 3.5 MPa) > Z250 (2.15 ± 1.1 MPa) > E-CCP10 (2.08 ± 2.1 MPa) > E-CCP5 (0.94 ± 0.8 MPa) > E-CCP0 (0.66 ± 0.2 MPa). In compressive testing, the maximum strength was observed by commercial control i.e., Z250 (210.36 ± 18 MPa) and E-C (206.55 ± 23 MPa), followed by E-CCP0 (108.06 ± 19 MPa), E-CCP5 (94.16 ± 9 MPa), and E-CCP10 (80.80 ± 13 MPa). The maximum number of hardness was shown by E-C (93.04 ± 8.23) followed by E-CCP0 (38.93 ± 9.21) > E-CCP10 (35.21 ± 12.31) > E-CCP5 (34.34 ± 12.49) > Z250 (25 ± 2.61). SEM images showed that the maximum apatite layer as shown by E-CCP10 and the order followed as E-CCP10 > E-CCP5 > E-CCP0 >Z250> E-C. CONCLUSION The experimental formulation showed an optimal degree of conversion with compromised mechanical properties when the polylysine percentage was increased. Apatite layer formation and polylysine at the interface may result in remineralization and ultimately lead to the prevention of secondary caries formation.
Collapse
Affiliation(s)
- Saadia Bano Lone
- Department of Dental Materials, Rashid Latif Dental College, Lahore, Pakistan
| | - Rabia Zeeshan
- Interdisciplinary Research Centre in Biomedical Materials, COMSATS University Islamabad, Lahore Campus, Lahore, Pakistan
| | - Hina Khadim
- Interdisciplinary Research Centre in Biomedical Materials, COMSATS University Islamabad, Lahore Campus, Lahore, Pakistan
| | - Muhammad Adnan Khan
- Department of Dental Materials, Institute of Basic Medical Sciences, Khyber Medical University Peshawar, Peshawar, Pakistan
| | - Abdul Samad Khan
- Department of Restorative Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Anila Asif
- Interdisciplinary Research Centre in Biomedical Materials, COMSATS University Islamabad, Lahore Campus, Lahore, Pakistan.
| |
Collapse
|
2
|
Alharbi G, Al Nahedh HN, Al-Saud LM, Shono N, Maawadh A. Effect of different finishing and polishing systems on surface properties of universal single shade resin-based composites. BMC Oral Health 2024; 24:197. [PMID: 38326838 PMCID: PMC10848531 DOI: 10.1186/s12903-024-03958-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2023] [Accepted: 01/30/2024] [Indexed: 02/09/2024] Open
Abstract
BACKGROUND Recently, universal single-shade resin composites have become increasingly available in the dental market. The modification of their composition can have an inadvertent effect on their physical and surface properties, and subsequently determinantal effect on their clinical function and longevity. Therefore, this study aimed to evaluate the effect of different finishing and polishing (F/P) systems on surface roughness (Ra), surface gloss (GU), and Vickers microhardness (VMH) of universal single-shade RBCs. MATERIALS AND METHODS Four commercial RBCs were used; the universal single-shade RBCs were Omnichroma, Charisma® Diamond ONE, and Vittra APS Unique, and a conventional nanocomposite Filtek™ Z250 XT was used as a control. The 3 F/P systems were Sof-Lex™ XT, Enhance®/PoGo®, and Diacomp® Plus Twist. A total of 160 discs were used for the 3 F/P system groups for all RBCs (n = 10). After F/P, the Ra, GU, and VMH were assessed. The data were analyzed using 2-way ANOVA at p-value < 0.05. RESULTS Significant differences were found among the four RBCs and the 3 F/P systems (p < .000). Omnichroma showed the lowest Ra and acceptable GU, but the lowest VMH. Charisma showed the highest Ra, acceptable GU, and VMH. Vittra showed acceptable Ra, GU, and VMH and Filtek showed the highest GU, VMH, and acceptable Ra. CONCLUSION Although conventional nanohybrid RBC (Filtek Z250 XT) showed better GU and VMH values, the universal single-shade RBCs demonstrated comparable surface properties. The highest GU & VMH and lowest Ra were achieved by Diacomp followed by Enhance and Soflex.
Collapse
Affiliation(s)
- Ghada Alharbi
- Department of Restorative Dental Science, College of Dentistry, King Saud University, P.O. Box 60169, Riyadh, 11545, Saudi Arabia.
- Department of Clinical Dental Sciences, College of Dentistry, Princess Nourah bint Abdulrahman University, Box 84428, Riyadh, PO, 11671, Saudi Arabia.
| | - Hend Na Al Nahedh
- Department of Restorative Dental Science, College of Dentistry, King Saud University, P.O. Box 60169, Riyadh, 11545, Saudi Arabia
| | - Loulwa M Al-Saud
- Department of Restorative Dental Science, College of Dentistry, King Saud University, P.O. Box 60169, Riyadh, 11545, Saudi Arabia
| | - Nourah Shono
- Department of Restorative Dental Science, College of Dentistry, King Saud University, P.O. Box 60169, Riyadh, 11545, Saudi Arabia
| | - Ahmed Maawadh
- Department of Restorative Dental Science, College of Dentistry, King Saud University, P.O. Box 60169, Riyadh, 11545, Saudi Arabia
| |
Collapse
|
3
|
Elgammal YA, Temirek MM, Hassanein OE, Abdelaziz MM. The Effect of Different Finishing and Polishing Systems on Surface Properties of New Flowable Bulk-fill Resin Composite. J Contemp Dent Pract 2023; 24:587-594. [PMID: 38193183 DOI: 10.5005/jp-journals-10024-3548] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2024]
Abstract
AIM The purpose of this research was to explore how various finishing and polishing techniques affect the surface roughness (Ra) and gloss of flowable bulk-fill injectable resin composite utilized for posterior teeth restoration, following exposure to a range of food-simulating liquids (FSLs) over three months. MATERIALS AND METHODS This study comprised fifty-six disk specimens of G-aenial™ Bulk Injectable flowable resin composite which were created using a Teflon mold (10 × 4 mm). Two techniques of finishing and polishing (F/P) were employed: The two-step 3M™ Sof-Lex™ F/P spiral wheels system and the multiple-step 3M™ Sof-Lex™ XT finishing disks supplemented by the Ultradent Jiffy HiShine polisher cup system. The Ra and gloss of the prepared specimens were measured using an interference microscope system and Horiba gloss checker respectively, immediately post-finishing and polishing and then reassessed after three months in artificial saliva and Coca-Cola. RESULTS The two-step system showed a statistically significant difference, exhibiting greater "surface roughness (Ra)" and lower "surface gloss (GU)" mean values compared to the multiple-step system under different storage conditions, particularly after 3 months of storage (p = 0.001). CONCLUSION The multiple-step polishing system improved the "Ra" and "GU" of resin composite, suggesting their suitability for posterior resin composite restorations. Acidic media had a deleterious impact on the "Ra" and "GU" of resin composite restoration. CLINICAL SIGNIFICANCE The quality of resin composite restorations can be significantly improved with the correct use of finishing and polishing systems, particularly in complex areas of posterior teeth restorations, leading to successful dental procedures.
Collapse
Affiliation(s)
- Yara A Elgammal
- Department of Conservative Dentistry, Faculty of Dentistry, October 6 University, Giza, Egypt, Phone: +20 1157564592, e-mail: , Orcid: https://orcid.org/0009-0006-0848-9156
| | - Marwa M Temirek
- Department of Conservative Dentistry, Faculty of Dentistry, October 6 University, Giza, Egypt; Department of Operative Dentistry, Faculty of Dentistry, Fayoum University, Fayoum, Egypt, Orcid: https://orcid.org/0000-0002-7243-6773
| | - Olfat E Hassanein
- Department of Conservative Dentistry, Faculty of Dentistry, Cairo University, Cairo, Egypt
| | - Monaliza M Abdelaziz
- Department of Conservative Dentistry, Faculty of Dentistry, October 6 University, Giza, Egypt, Orcid: https://orcid.org/0000-0002-3923-6083
| |
Collapse
|
4
|
de Oliveira AG, Rocha RS, Spinola MDS, Batista GR, Bresciani E, Caneppele TMF. Surface smoothness of resin composites after polishing-A systematic review and network meta-analysis of in vitro studies. Eur J Oral Sci 2023; 131:e12921. [PMID: 36781294 DOI: 10.1111/eos.12921] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Accepted: 01/21/2023] [Indexed: 02/15/2023]
Abstract
A systematic review and network meta-analysis was performed to provide evidence for the best polishing protocol for different types of resin composites to minimize surface roughness. A search was performed in PubMed, Scopus, Web of Science, LILACS, BBO, EMBASE, and Cochrane Library on July 2, 2019 (updated in December, 2020). In vitro studies that included at least two systems for polishing resin composites and analyzed surface roughness were included. The risk of bias was evaluated. A random-effects Bayesian-mixed treatment comparison model was used to compare surface roughness in resin composites with the different types of polishers. Surface under the cumulative ranking curve (SUCRA) analysis was performed to rank the probability for the best polishing system. After removal of duplicates, title and abstract screening yielded 34 studies. Network meta-analysis was not possible for hybrid and microhybrid composites. SUCRA analysis showed that abrasive paper discs allowed greater surface smoothness for nanohybrid and nanofill composites to a probability of between 83% and 91.6%. Silicon carbide brush had a 78.2% probability of being the best system for microfill composites. The use of abrasive paper disc polishers showed a favorable result in nanofill and nanohybrid resin composites. Silicon carbide brush has a greater chance of promoting a smoother surface for microfill resin composites.
Collapse
Affiliation(s)
- Ananda Gomes de Oliveira
- Department of Restorative Dentistry, Institute of Science and Technology, São Paulo State University, São José dos Campos, São Paulo, Brazil
| | - Rafael Santos Rocha
- Department of Restorative Dentistry, Institute of Science and Technology, São Paulo State University, São José dos Campos, São Paulo, Brazil
| | - Manuela da Silva Spinola
- Department of Restorative Dentistry, Braz Cubas University, São José dos Campos, São Paulo, Brazil
| | - Graziela Ribeiro Batista
- Department of Restorative Dentistry, Missouri School of Dentistry and Oral Health, A. T. Still University, São José dos Campos, São Paulo, Brazil
| | - Eduardo Bresciani
- Department of Restorative Dentistry, Institute of Science and Technology, São Paulo State University, São José dos Campos, São Paulo, Brazil
| | - Taciana Marco Ferraz Caneppele
- Department of Restorative Dentistry, Institute of Science and Technology, São Paulo State University, São José dos Campos, São Paulo, Brazil
| |
Collapse
|
5
|
In Vitro Comparison of Surface Roughness, Flexural, and Microtensile Strength of Various Glass-Ionomer-Based Materials and a New Alkasite Restorative Material. Polymers (Basel) 2023; 15:polym15030650. [PMID: 36771950 PMCID: PMC9920171 DOI: 10.3390/polym15030650] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2022] [Revised: 01/19/2023] [Accepted: 01/23/2023] [Indexed: 01/31/2023] Open
Abstract
This study aims to evaluate the physical properties of Cention N and various glass-ionomer-based materials in vitro. The groups were obtained as follows: Group 1 (LC-Cent): light-cured Cention N; Group 2 (SC-Cent): self-cured Cention N; Group 3 (COMP): composite (3M Universal Restorative 200); Group 4 (DYRA): compomer (Dyract XP); Group 5 (LINER): Glass Liner; Group 6 (FUJI): FujiII LC Capsule; and Group 7 (NOVA): Nova Glass LC. For the microtensile bond strength (μTBS) test, 21 extracted human molar teeth were used. The enamel of the teeth was removed, and flat dentin surfaces were obtained. Materials were applied up to 3 mm, and sticks were obtained from the teeth. Additionally, specimens were prepared, and their flexural strength and surface roughness (Ra) were evaluated. Herein, data were recorded using SPSS 22.0, and the flexural strength, μTBS, and Ra were statistically analyzed. According to the surface roughness tests, the highest Ra values were observed in Group 6 (FUJI) (0.33 ± 0.1), whereas the lowest Ra values were observed in Group 2 (SC-Cent) (0.17 ± 0.04) (p < 0.05). The flexural strengths of the materials were compared, and the highest value was obtained in Group 2 (SC-Cent) (86.32 ± 15.37), whereas the lowest value was obtained in Group 5 (LINER) (41.75 ± 10.05) (p < 0.05). When the μTBS of materials to teeth was evaluated, the highest μTBS was observed in Group 3 (COMP) (16.50 ± 7.73) and Group 4 (DYRA) (16.36 ± 4.64), whereas the lowest μTBS was found in Group 7 (NOVA) (9.88 ± 1.87) (p < 0.05). According to the μTBS results of materials-to-materials bonding, both Group 2 (SC-Cent) and Group 1 (LC-Cent) made the best bonding with Group 3 (COMP) (p < 0.05). It can be concluded that self-cured Cention N had the highest flexural strength and lowest surface roughness of the seven materials tested. Although the bond strength was statistically lower than conventional composites and compomers, it was similar to resin-modified glass ionomer cements. Additionally, the best material-to-material bonding was found between self-cured Cention N and conventional composites.
Collapse
|
6
|
Surface roughness and gloss alteration of polished resin composites with various filler types after simulated toothbrush abrasion. J Dent Sci 2022. [DOI: 10.1016/j.jds.2022.12.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022] Open
|
7
|
The Use of the Diode Laser against the Microbiome on Composites Closing the Screw Access Hall (Sah) in the Reconstruction of Dental Implants: Ex Vivo Studies. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:ijerph19127494. [PMID: 35742743 PMCID: PMC9224170 DOI: 10.3390/ijerph19127494] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/03/2022] [Accepted: 06/16/2022] [Indexed: 02/05/2023]
Abstract
Patients undergoing implant treatment are at risk of peri-implant bone loss, which is most often caused by the adverse effects of microorganisms, but there are few proven procedures for their reduction. The aim of the research was to identify the microorganisms inhabiting the composites used to close the screw access hole (SAH), compare them numerically with those present on the surface of crowns and teeth, and optimize the doses of the diode laser, which will reduce microorganisms and will not deteriorate the roughness of polished composites. Patients were swabbed from the surface of SAH composites, from porcelain and zirconium restorations, and from teeth, and then the number of microorganisms was determined by using a culture technique. Microorganisms were identified by MALDI–TOF MS and NGS sequencing. The effectiveness of diode laser irradiation was achieved by using four variants of exposure. After polishing and laser irradiation, the surface roughness of the composites was studied by using optical profilometry. On the surface of SAH, 106 to 108 microorganisms were identified at 0.4 cm2, including many pathogenic species. Among the materials used for the reconstruction of dental implants, the greatest microbiological contamination was found on the composites used to close the SAH. The diode laser with a wavelength of 810 nm with an average power of 3.84 W, during 60 s and 2 × 30 s, has a biocidal effect and does not significantly change the surface roughness of composites. The best reduction of microorganisms was achieved on a composite polished with a polishing rubber and then with a Sof-Lex™ Pre-Polishing Spiral beige (3M ESPE, Ave. St. Paul., MN, USA). Studies have shown that using the optimal laser dose can help treat periimplantitis. These studies provide important information on the possibility of the effective elimination of microorganisms by using a diode laser in the treatment of peri-implant bone loss.
Collapse
|
8
|
Németh KD, Haluszka D, Seress L, Lovász BV, Szalma J, Lempel E. Effect of Air-Polishing and Different Post-Polishing Methods on Surface Roughness of Nanofill and Microhybrid Resin Composites. Polymers (Basel) 2022; 14:polym14091643. [PMID: 35566812 PMCID: PMC9100913 DOI: 10.3390/polym14091643] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Revised: 04/11/2022] [Accepted: 04/12/2022] [Indexed: 11/27/2022] Open
Abstract
Air-abrasion is a popular prophylactic procedure to maintain oral hygiene. However, depending on the applied air-abrasive powder, it can damage the surface of the tooth and restorations, making it susceptible to plaque accumulation. The purpose of this study was to investigate the effect of 5 s and 10 s air-abrasion of calcium carbonate on surface roughness (Ra) of enamel, nanofill, and microhybrid resin-composites and the effect of post-polishing with two-step rubber- (RP) or one-step brush polisher (BP) to re-establish the surface smoothness. Surface topography was visualized by scanning-electron-microscopy. The quantitative measurement of the Ra was carried out with atomic-force-microscopy. Air-abrasion for 10 s decreased the Ra of enamel as a result of abrasion of the natural surface texture. Post-polishing with RP after 10 s air-abrasion did not change the Ra or BP; however, Ra was increased significantly by scratching the surface. Air-abrasion increased the Ra of resin composites significantly, irrespective of the application time. While RP provided a similarly smooth surface to the control in the case of microhybrid resin composite, BP increased the Ra significantly. The Ra for the control group of the nanofill-resin composite was initially high, which was further increased by air-abrasion. RP and BP re-established the initial Ra with deeper and shallower scratches after BP. Both the material and treatment type showed a large effect on Ra.
Collapse
Affiliation(s)
- Kinga Dorottya Németh
- Department of Restorative Dentistry and Periodontology, University of Pécs Medical School, Dischka Gy. Street 5, 7621 Pécs, Hungary;
| | - Dóra Haluszka
- Department of Biophysics and Radiation Biology, Semmelweis University, Tűzoltó Street 37–47, 1094 Budapest, Hungary;
| | - László Seress
- Central Electron Microscope Laboratory, University of Pécs Medical School, Szigeti Street 12, 7624 Pécs, Hungary;
| | - Bálint Viktor Lovász
- Department of Oral and Maxillofacial Surgery, University of Pécs Medical School, Dischka Gy. Street 5, 7621 Pécs, Hungary; (B.V.L.); (J.S.)
| | - József Szalma
- Department of Oral and Maxillofacial Surgery, University of Pécs Medical School, Dischka Gy. Street 5, 7621 Pécs, Hungary; (B.V.L.); (J.S.)
| | - Edina Lempel
- Department of Restorative Dentistry and Periodontology, University of Pécs Medical School, Dischka Gy. Street 5, 7621 Pécs, Hungary;
- Correspondence: ; Tel.: +36-72-535926
| |
Collapse
|
9
|
FİDAN M, DERELİ Z. Effect of Polishing Systems on the Color and Surface Properties of Resin Composites in the Process of Accelerated Artificial Aging. CLINICAL AND EXPERIMENTAL HEALTH SCIENCES 2022. [DOI: 10.33808/clinexphealthsci.1014098] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Objective: This study aimed to investigate the effects of polishing system on the color stability, surface roughness, and hardness of resin composites in the presence and absence of accelerated artificial aging (AAA).
Methods: Six resin composites (Universal Restorative 200, G-Aenial Anterior, Ceram-X Duo, Admira, IPS Empress Direct, Clearfil Majesty Esthetic) were evaluated. Thirty disc-shaped samples were prepared for each composite group. Resin composite groups were divided into three subgroups: control (Mylar strip), disc (Optidisc), and rubber (Dimanto) (n=10). Color change (ΔE00) was calculated using the CIEDE 2000 formula. Before and after AAA, the surface roughness (Ra, μm) and hardness (VHN) values were measured. Data were analysed using ANOVA,
the Bonferroni test, and Pearson correlation (p
Collapse
Affiliation(s)
| | - Zeynep DERELİ
- NECMETTİN ERBAKAN ÜNİVERSİTESİ, DİŞ HEKİMLİĞİ FAKÜLTESİ
| |
Collapse
|
10
|
Cayo-Rojas C, Ramírez-Vargas G, Ladera-Castañeda M, López-Gurreonero C, Cornejo-Pinto A, Cachay-Criado H, Cervantes-Ganoza L. Surface roughness in nanoparticle resin composites subjected to two polishing systems: An in vitro comparative study. J Int Soc Prev Community Dent 2022; 13:114-123. [DOI: 10.4103/jispcd.jispcd_279_21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2021] [Revised: 11/29/2021] [Accepted: 12/05/2021] [Indexed: 11/11/2022] Open
|
11
|
Jaramillo-Cartagena R, López-Galeano EJ, Latorre-Correa F, Agudelo-Suárez AA. Effect of Polishing Systems on the Surface Roughness of Nano-Hybrid and Nano-Filling Composite Resins: A Systematic Review. Dent J (Basel) 2021; 9:dj9080095. [PMID: 34436007 PMCID: PMC8391685 DOI: 10.3390/dj9080095] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2021] [Revised: 08/10/2021] [Accepted: 08/10/2021] [Indexed: 11/26/2022] Open
Abstract
Background: The polishing of surface roughness is an important characteristic of composite resins and is directly related to the longevity of the restoration and patient comfort. Different polishing systems utilize different protocols, as reported in the literature. This systematic review (SR) aimed to synthesize and analyze the available scientific evidence about the effect of polishing systems on the surface roughness of nano-hybrid and nano-filling composite resins. Methods: The study protocol of this SR was registered at the International Prospective Register of Systematic Reviews -PROSPERO- (CRD4201705653). A search was conducted in PubMed-Medline, Scopus, LILACS, EMBASE, for the period 2007–2020. Quality appraisal and a descriptive analysis of the papers that met the inclusion criteria were conducted. Results: 18 records were included. Seven polishing systems (PS) of one step were found, seven PS of two steps, eight PS of three steps, three PS of four steps, and four PS of five steps. Polishing protocols (PP) varied, with application times ranging from 10 s to 60 s with speeds between 10,000 and 30,000 RPM. Regarding composition, the aluminum oxide was one of the most important components used to achieve a smooth surface. Conclusions: Multistep polishing systems were the most effective (i.e., Astropol and Sof-Lex Discs).
Collapse
|
12
|
Surface Geometry of Four Conventional Nanohybrid Resin-Based Composites and Four Regular Viscosity Bulk Fill Resin-Based Composites after Two-Step Polishing Procedure. BIOMED RESEARCH INTERNATIONAL 2020; 2020:6203053. [PMID: 32851084 PMCID: PMC7441458 DOI: 10.1155/2020/6203053] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/15/2020] [Accepted: 07/28/2020] [Indexed: 11/17/2022]
Abstract
Objectives. The aim of the study was to determine the quantitative and qualitative surface structure of contemporary RBCs in posterior teeth reconstructions: regular viscosity bulk fill and conventional composites, obtained after two-stage polishing procedure. Materials and Methods. Four conventional nanohybrid composites (Tetric EvoCeram, GrandioSO, Filtek Z550, and Ceram·X Mono) and four regular viscosity bulk fill composites (Tetric EvoCeram Bulk Fill, X-tra fil, Filtek Bulk Fill Posterior, and QuixFil) were tested. Samples of each RBC were prepared using PMMA cylindrical mold. After two-step polishing procedure, a surface geometry was evaluated under profilometry (Turbowave v. 7.36, Hommel-Etamic) and SEM (VEGA 3, Tescan Analytics). To evaluate differences between values, the following nonparametric tests were used: Friedman’s ANOVA, Wilcoxon’s matched-pair test, ANOVA Kruskal-Wallis, and Mann-Whitney U. Results. All conventional RBCs showed Ra values in the range of 0.20-0.26 μm. Bulk fill showed higher values in range of 0.49-1.36 μm except for Filtek Bulk Fill Posterior, which achieved 0.23 μm Ra value. SEM images of conventional RBCs were described as smooth surfaces with slight damage except for TEC, which presented smooth surface with no damage. Bulk fill composites showed rough surface, except for TBF, which presented smooth surface with slight damage. Conclusions. Regular viscosity bulk fill composites do not constitute a homogeneous group regarding surface roughness after polishing. They obtain, for the most part, poorer smoothness values after polishing than conventional RBCs.
Collapse
|
13
|
Daud A, Adams AJ, Shawkat A, Gray G, Wilson NH, Lynch CD, Blum IR. Effects of toothbrushing on surface characteristics of microhybrid and nanofilled resin composites following different finishing and polishing procedures. J Dent 2020; 99:103376. [DOI: 10.1016/j.jdent.2020.103376] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Revised: 05/13/2020] [Accepted: 05/14/2020] [Indexed: 11/30/2022] Open
|
14
|
Daud A, Gray G, Lynch CD, Wilson NHF, Blum IR. A randomised controlled study on the use of finishing and polishing systems on different resin composites using 3D contact optical profilometry and scanning electron microscopy. J Dent 2018; 71:25-30. [PMID: 29360492 DOI: 10.1016/j.jdent.2018.01.008] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2018] [Accepted: 01/18/2018] [Indexed: 11/16/2022] Open
Abstract
OBJECTIVES The aim of this study was to evaluate theeffects of different finishing and polishing techniques on the surface roughness of microhybrid and nanofilled resin composites. METHODS The resin composites included were Filtek Z250 (a universal microhybrid resin composite) and Filtek Supreme XTE (a universal nanofill resin composite). Ninety cylindrical-shaped specimens were prepared for each composite resin material. The polishing methods used included tungsten carbide bur (TC); diamond bur (Db); Sof-Lex discs (S); Enhance PoGo discs (PG); TC + S; Db + S; TC + PG; Db + PG. Polymerisation against a Mylar strip without finishing and polishing acted as the control group. Surface roughness was measured using a 3D contact optical profilometer and surface morphology was examined by scanning electron microscope examination. RESULTS The results showed that the Mylar-formed surfaces were smoothest for both composites. Finishing with the 20 μm diamond finishing bur caused significantly greater surface irregularity (P < 0.0001) and damage than finishing with the tungsten carbide finishing bur. The Enhance PoGo polishing system produced smoother surfaces than the Sof-Lex disc polishing system; this difference was statistically highly significant (P < 0.0001). CONCLUSION For both composites, the Mylar-formed surfaces were smoothest. Where indicated clinically, finishing is better conducted using a tungsten carbide bur- rather than a diamond finishing bur. The Enhance PoGo system was found to produce a smoother surface finish than the Sof-Lex system. CLINICAL SIGNIFICANCE If finishing and polishing is required the use a tungsten carbide finishing bur followed by Enhance PoGo polishing may be found to result in the smoothest surface finish.
Collapse
Affiliation(s)
- Alaa Daud
- School of Oral & Dental Sciences, University of Bristol Dental School, UK
| | - Gordon Gray
- School of Oral & Dental Sciences, University of Bristol Dental School, UK
| | | | | | - Igor R Blum
- Maurice Wohl Dental Centre, King's College Hospital and King's College London Dental Institute, UK.
| |
Collapse
|