1
|
Mallat J, Siuba MT, Abou-Arab O, Kovacevic P, Ismail K, Duggal A, Guinot PG. Changes in pulse pressure variation induced by passive leg raising test to predict preload responsiveness in mechanically ventilated patients with low tidal volume in ICU: a systematic review and meta-analysis. Crit Care 2025; 29:18. [PMID: 39789598 PMCID: PMC11720620 DOI: 10.1186/s13054-024-05238-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2024] [Accepted: 12/26/2024] [Indexed: 01/12/2025] Open
Abstract
BACKGROUND Pulse pressure variation (PPV) is limited in low tidal volume mechanical ventilation. We conducted this systematic review and meta-analysis to evaluate whether passive leg raising (PLR)-induced changes in PPV can reliably predict preload/fluid responsiveness in mechanically ventilated patients with low tidal volume in the intensive care unit. METHODS PubMed, Embase, and Cochrane databases were screened for diagnostic research relevant to the predictability of PPV change after PLR in low-tidal volume mechanically ventilated patients. The QUADAS-2 scale was used to assess the risk of bias of the included studies. In-between study heterogeneity was assessed through the I2 indicator. Publication bias was assessed by the Deeks' funnel plot asymmetry test. Summary receiving operating characteristic curve (SROC), pooled sensitivity, and specificity were calculated. RESULTS Five studies with a total of 474 patients were included in this meta-analysis. The SROC of the absolute PPV change resulted in an area under the curve of 0.91 (95% CI 0.88-0.93), with overall pooled sensitivity and specificity of 0.88 (95% CI 0.82-0.91) and 0.83 (95% CI 0.76-0.89), respectively. The diagnostic odds ratio was 35 (95% CI 19-67). The mean and median cutoff values of PLR-induced absolute change in absolute PPV were both -2 points and ranged from -2.5 to -1 points. Overall, there was no significant heterogeneity with I2 = 0%. There was no significant publication bias. Fagan's nomogram showed that with a pre-test probability of 50%, the post-test probability reached 84% and 17% for the positive and negative tests, respectively. CONCLUSIONS PLR-induced change in absolute PPV has good diagnostic performance in predicting preload/fluid responsiveness in ICU patients on mechanical ventilation with low tidal volume. Trial registration PROSPERO (CRD42024496901). Registered on 15 January 2024.
Collapse
Affiliation(s)
- Jihad Mallat
- Critical Care Division, Integrated Hospital Care Institute, Cleveland Clinic Abu Dhabi, 112412, Abu Dhabi, United Arab Emirates.
- Cleveland Clinic Lerner College of Medicine of Case Western Reserve University, Cleveland, OH, 44106, USA.
| | - Matthew T Siuba
- Department of Critical Care Medicine Integrated Hospital Care Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Osama Abou-Arab
- Anesthesia and Critical Care Department, Amiens Hospital University, 80054, Amiens, France
| | - Pedja Kovacevic
- Medical Intensive Care Unit, University Clinical Centre of the Republic of Srpska, Dvanaest Beba Bb, 78000, Banja Luka, Republic of Srpska, Bosnia and Herzegovina
- Faculty of Medicine, University of Banja Luka, Save Mrkalja 14, 78000, Banja Luka, Republic of Srpska, Bosnia and Herzegovina
| | - Khaled Ismail
- Critical Care Division, Integrated Hospital Care Institute, Cleveland Clinic Abu Dhabi, 112412, Abu Dhabi, United Arab Emirates
| | - Abhijit Duggal
- Department of Critical Care Medicine Integrated Hospital Care Institute, Cleveland Clinic, Cleveland, OH, USA
| | | |
Collapse
|
2
|
Griva P, Kapetanakis EI, Milionis O, Panagouli K, Fountoulaki M, Sidiropoulou T. Tidal Volume Challenge to Assess Volume Responsiveness with Dynamic Preload Indices During Non-Cardiac Surgery: A Prospective Study. J Clin Med 2024; 14:101. [PMID: 39797182 PMCID: PMC11721188 DOI: 10.3390/jcm14010101] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2024] [Revised: 11/30/2024] [Accepted: 12/09/2024] [Indexed: 01/13/2025] Open
Abstract
Background/Objectives: The aim of this study is to assess whether changes in Pulse Pressure Variation (PPV) and Stroke Volume Variation (SVV) following a VtC can predict the response to fluid administration in patients undergoing surgery under general anesthesia with protective mechanical ventilation. Methods: A total of 40 patients undergoing general surgery or vascular surgery without clamping the aorta were enrolled. Protective mechanical ventilation was applied, and the radial artery was catheterized in all patients. The protocol began one hour after the induction of general anesthesia and the stabilization of hemodynamic parameters. The parameters PPV6 and SVV6 were recorded during ventilation with a Vt of 6 mL/kg Ideal Body Weight (IBW) (T1). Then, the Vt was increased to 8 mL/kg IBW for 3 min without changing other respiratory parameters. After the VtC, the parameters PPV8 and SVV8 (T2) were recorded. After the stabilization of hemodynamic parameters, volume expansion (VE) was administered with colloid fluid of 6 mL/kg IBW. Parameters before (T3) and 5 min after fluid challenge (T4) were recorded. The change in the Stroke Volume Index (SVI) before and after VE was used to indicate fluid responsiveness. Patients were classified as fluid responders (SVI ≥ 10%) or non-responders (SVI < 10%). Results: The parameter ΔPPV(6-8) demonstrated good predictive ability to predict fluid responsiveness, evidenced by an Area Under the Curve (AUC) of 0.86 [95% Confidence Interval (CI) 0.74 to 0.95, p < 0.0001]. The threshold of ΔPPV(6-8) exceeding 2% identified responders with a sensitivity of 83% (95% CI 0.45 to 1.0, p < 0.0001) and a specificity of 73% (95% CI 0.48 to 1.0, p < 0.0001). The parameter ΔSVV(6-8) also revealed good predictive ability, reflected by an AUC of 0.82 (95% CI 0.67 to 0.94, p < 0.0001). The criterion ΔSVV(6-8) greater than 2% pinpointed responders with a sensitivity of 83% (95% CI 0.71 to 1.0, p < 0.001) and a specificity of 77% (95% CI 0.44 to 1.0, p < 0.001). Conclusions: This study demonstrates that VtC possesses good predictive ability for fluid responsiveness in patients undergoing general surgery.
Collapse
Affiliation(s)
- Panagiota Griva
- Second Department of Anesthesiology, Attikon University Hospital, National and Kapodistrian University of Athens, 12461 Athens, Greece; (P.G.); (O.M.); (K.P.); (M.F.)
| | - Emmanouil I. Kapetanakis
- Department of Thoracic Surgery, Attikon University Hospital, National and Kapodistrian University of Athens, 12461 Athens, Greece;
| | - Orestis Milionis
- Second Department of Anesthesiology, Attikon University Hospital, National and Kapodistrian University of Athens, 12461 Athens, Greece; (P.G.); (O.M.); (K.P.); (M.F.)
| | - Konstantina Panagouli
- Second Department of Anesthesiology, Attikon University Hospital, National and Kapodistrian University of Athens, 12461 Athens, Greece; (P.G.); (O.M.); (K.P.); (M.F.)
| | - Maria Fountoulaki
- Second Department of Anesthesiology, Attikon University Hospital, National and Kapodistrian University of Athens, 12461 Athens, Greece; (P.G.); (O.M.); (K.P.); (M.F.)
| | - Tatiana Sidiropoulou
- Second Department of Anesthesiology, Attikon University Hospital, National and Kapodistrian University of Athens, 12461 Athens, Greece; (P.G.); (O.M.); (K.P.); (M.F.)
| |
Collapse
|
3
|
Chen Q, Wu B, Deng M, Wei K. Effect of different targets of goal-directed fluid therapy on intraoperative hypotension and fluid infusion in robot-assisted laparoscopic gynecological surgery: a randomized non-inferiority trial. J Robot Surg 2024; 18:127. [PMID: 38492125 DOI: 10.1007/s11701-024-01875-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2023] [Accepted: 02/17/2024] [Indexed: 03/18/2024]
Abstract
Carotid corrected flow time (FTc) and tidal volume challenge pulse pressure variation (VtPPV) are useful clinical parameters for assessing volume status and fluid responsiveness in robot-assisted surgery, but their usefulness as goal-directed fluid therapy (GDFT) targets is unclear. We investigated whether FTc or VtPPV as targets are inferior to PPV in GDFT. This single-center, prospective, randomized, non-inferiority study included 133 women undergoing robot-assisted laparoscopic gynecological surgery in the modified head-down lithotomy position. Patients were equally divided into three groups, and the GDFT protocol was guided by FTc, VtPPV, or PPV during surgery. Primary outcomes were non-inferiority of the time-weighted average of hypotension, intraoperative fluid volume, and urine output. Secondary outcomes were optic nerve sheath diameter (ONSD) pre- and post-operatively and creatinine and blood urea nitrogen preoperatively and on day 1 post-operatively. No significant differences were observed in intraoperative hypotension index, infusion and urine volumes, and ONSD post-operatively between the FTc and VtPPV groups and the PPV group. No differences in serum creatinine and urea nitrogen levels were identified between the FTc and VtPPV groups preoperatively, but on day 1 post-operatively, the urea nitrogen level in the FTc group was higher than that in the PPV group (4.09 ± 1.28 vs. 3.0 ± 1.1 mmol/L, 1.08 [0.59, 1.58], p < 0.0001), and the difference from the preoperative value was smaller than that in the PPV group (- 2 [- 2.97, 1.43] vs. - 1.34 [- 1.9, - 0.67], p = 0.004). FTc- or VtPPV-guided protocols are not inferior to that of PPV in GDFT during robot-assisted laparoscopic surgery in the modified head-down lithotomy position.Trial registration: Chinese Clinical Trial Registry (ChiCTR2200064419).
Collapse
Affiliation(s)
- Qi Chen
- Department of Anesthesiology, The First Affiliated of Chongqing Medical University, Chongqing, China
- Department of Anesthesiology, Chongqing University Cancer Hospital, Chongqing, China
| | - Bin Wu
- Department of Anesthesiology, The First Affiliated of Chongqing Medical University, Chongqing, China
| | - Meiling Deng
- Department of Anesthesiology, The First Affiliated of Chongqing Medical University, Chongqing, China
| | - Ke Wei
- Department of Anesthesiology, The First Affiliated of Chongqing Medical University, Chongqing, China.
| |
Collapse
|
4
|
Messina A, Calabrò L, Pugliese L, Lulja A, Sopuch A, Rosalba D, Morenghi E, Hernandez G, Monnet X, Cecconi M. Fluid challenge in critically ill patients receiving haemodynamic monitoring: a systematic review and comparison of two decades. Crit Care 2022; 26:186. [PMID: 35729632 PMCID: PMC9210670 DOI: 10.1186/s13054-022-04056-3] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2022] [Accepted: 06/07/2022] [Indexed: 11/10/2022] Open
Abstract
Abstract
Introduction
Fluid challenges are widely adopted in critically ill patients to reverse haemodynamic instability. We reviewed the literature to appraise fluid challenge characteristics in intensive care unit (ICU) patients receiving haemodynamic monitoring and considered two decades: 2000–2010 and 2011–2021.
Methods
We assessed research studies and collected data regarding study setting, patient population, fluid challenge characteristics, and monitoring. MEDLINE, Embase, and Cochrane search engines were used. A fluid challenge was defined as an infusion of a definite quantity of fluid (expressed as a volume in mL or ml/kg) in a fixed time (expressed in minutes), whose outcome was defined as a change in predefined haemodynamic variables above a predetermined threshold.
Results
We included 124 studies, 32 (25.8%) published in 2000–2010 and 92 (74.2%) in 2011–2021, overall enrolling 6,086 patients, who presented sepsis/septic shock in 50.6% of cases. The fluid challenge usually consisted of 500 mL (76.6%) of crystalloids (56.6%) infused with a rate of 25 mL/min. Fluid responsiveness was usually defined by a cardiac output/index (CO/CI) increase ≥ 15% (70.9%). The infusion time was quicker (15 min vs 30 min), and crystalloids were more frequent in the 2011–2021 compared to the 2000–2010 period.
Conclusions
In the literature, fluid challenges are usually performed by infusing 500 mL of crystalloids bolus in less than 20 min. A positive fluid challenge response, reported in 52% of ICU patients, is generally defined by a CO/CI increase ≥ 15%. Compared to the 2000–2010 decade, in 2011–2021 the infusion time of the fluid challenge was shorter, and crystalloids were more frequently used.
Collapse
|
5
|
Monnet X, Shi R, Teboul JL. Prediction of fluid responsiveness. What’s new? Ann Intensive Care 2022; 12:46. [PMID: 35633423 PMCID: PMC9148319 DOI: 10.1186/s13613-022-01022-8] [Citation(s) in RCA: 91] [Impact Index Per Article: 30.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2022] [Accepted: 05/09/2022] [Indexed: 02/07/2023] Open
Abstract
AbstractAlthough the administration of fluid is the first treatment considered in almost all cases of circulatory failure, this therapeutic option poses two essential problems: the increase in cardiac output induced by a bolus of fluid is inconstant, and the deleterious effects of fluid overload are now clearly demonstrated. This is why many tests and indices have been developed to detect preload dependence and predict fluid responsiveness. In this review, we take stock of the data published in the field over the past three years. Regarding the passive leg raising test, we detail the different stroke volume surrogates that have recently been described to measure its effects using minimally invasive and easily accessible methods. We review the limits of the test, especially in patients with intra-abdominal hypertension. Regarding the end-expiratory occlusion test, we also present recent investigations that have sought to measure its effects without an invasive measurement of cardiac output. Although the limits of interpretation of the respiratory variation of pulse pressure and of the diameter of the vena cava during mechanical ventilation are now well known, several recent studies have shown how changes in pulse pressure variation itself during other tests reflect simultaneous changes in cardiac output, allowing these tests to be carried out without its direct measurement. This is particularly the case during the tidal volume challenge, a relatively recent test whose reliability is increasingly well established. The mini-fluid challenge has the advantage of being easy to perform, but it requires direct measurement of cardiac output, like the classic fluid challenge. Initially described with echocardiography, recent studies have investigated other means of judging its effects. We highlight the problem of their precision, which is necessary to evidence small changes in cardiac output. Finally, we point out other tests that have appeared more recently, such as the Trendelenburg manoeuvre, a potentially interesting alternative for patients in the prone position.
Collapse
|