1
|
Li Z, Yang Z, Lu J, Zhu Q, Wang Y, Zhao M, Li Z, Fu J. Deep learning-based dose map prediction for high-dose-rate brachytherapy. Phys Med Biol 2023; 68:175015. [PMID: 37589292 DOI: 10.1088/1361-6560/acecd2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Accepted: 08/02/2023] [Indexed: 08/18/2023]
Abstract
Background. Creating a clinically acceptable plan in the time-sensitive clinic workflow of brachytherapy is challenging. Deep learning-based dose prediction techniques have been reported as promising solutions with high efficiency and accuracy. However, current dose prediction studies mainly target EBRT which are inappropriate for brachytherapy, the model designed specifically for brachytherapy has not yet well-established.Purpose. To predict dose distribution in brachytherapy using a novel Squeeze and Excitation Attention Net (SE_AN) model.Method. We hypothesized the tracks of192Ir inside applicators are essential for brachytherapy dose prediction. To emphasize the applicator contribution, a novel SE module was integrated into a Cascaded UNet to recalibrate informative features and suppress less useful ones. The Cascaded UNet consists of two stacked UNets, with the first designed to predict coarse dose distribution and the second added for fine-tuning 250 cases including all typical clinical applicators were studied, including vaginal, tandem and ovoid, multi-channel, and free needle applicators. The developed SE_AN was subsequently compared to the classic UNet and classic Cascaded UNet (without SE module) models. The model performance was evaluated by comparing the predicted dose against the clinically approved plans using mean absolute error (MAE) of DVH metrics, includingD2ccandD90%.Results. The MAEs of DVH metrics demonstrated that SE_AN accurately predicted the dose with 0.37 ± 0.25 difference for HRCTVD90%, 0.23 ± 0.14 difference for bladderD2cc, and 0.28 ± 0.20 difference for rectumD2cc. In comparison studies, UNet achieved 0.34 ± 0.24 for HRCTV, 0.25 ± 0.20 for bladder, 0.25 ± 0.21 for rectum, and Cascaded UNet achieved 0.42 ± 0.31 for HRCTV, 0.24 ± 0.19 for bladder, 0.23 ± 0.19 for rectum.Conclusion. We successfully developed a method specifically for 3D brachytherapy dose prediction. Our model demonstrated comparable performance to clinical plans generated by experienced dosimetrists. The developed technique is expected to improve the standardization and quality control of brachytherapy treatment planning.
Collapse
Affiliation(s)
- Zhen Li
- Shanghai Sixth People's Hospital, Shanghai, People's Republic of China
| | - Zhenyu Yang
- Duke University, Durham, NC, United States of America
| | - Jiayu Lu
- Boston University, Boston, MA, United States of America
| | - Qingyuan Zhu
- Shanghai Sixth People's Hospital, Shanghai, People's Republic of China
| | - Yanxiao Wang
- Shanghai Sixth People's Hospital, Shanghai, People's Republic of China
| | - Mengli Zhao
- Shanghai Sixth People's Hospital, Shanghai, People's Republic of China
| | - Zhaobin Li
- Shanghai Sixth People's Hospital, Shanghai, People's Republic of China
| | - Jie Fu
- Shanghai Sixth People's Hospital, Shanghai, People's Republic of China
| |
Collapse
|
2
|
Berger D, Van Dyk S, Beaulieu L, Major T, Kron T. Modern Tools for Modern Brachytherapy. Clin Oncol (R Coll Radiol) 2023:S0936-6555(23)00182-6. [PMID: 37217434 DOI: 10.1016/j.clon.2023.05.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2022] [Revised: 03/28/2023] [Accepted: 05/04/2023] [Indexed: 05/24/2023]
Abstract
This review aims to showcase the brachytherapy tools and technologies that have emerged during the last 10 years. Soft-tissue contrast using magnetic resonance and ultrasound imaging has seen enormous growth in use to plan all forms of brachytherapy. The era of image-guided brachytherapy has encouraged the development of advanced applicators and given rise to the growth of individualised 3D printing to achieve reproducible and predictable implants. These advances increase the quality of implants to better direct radiation to target volumes while sparing normal tissue. Applicator reconstruction has moved beyond manual digitising, to drag and drop of three-dimensional applicator models with embedded pre-defined source pathways, ready for auto-recognition and automation. The simplified TG-43 dose calculation formalism directly linked to reference air kerma rate of high-energy sources in the medium water remains clinically robust. Model-based dose calculation algorithms accounting for tissue heterogeneity and applicator material will advance the field of brachytherapy dosimetry to become more clinically accurate. Improved dose-optimising toolkits contribute to the real-time and adaptive planning portfolio that harmonises and expedites the entire image-guided brachytherapy process. Traditional planning strategies remain relevant to validate emerging technologies and should continue to be incorporated in practice, particularly for cervical cancer. Overall, technological developments need commissioning and validation to make the best use of the advanced features by understanding their strengths and limitations. Brachytherapy has become high-tech and modern by respecting tradition and remaining accessible to all.
Collapse
Affiliation(s)
- D Berger
- International Atomic Energy Agency, Vienna International Centre, Vienna, Austria.
| | - S Van Dyk
- Radiation Therapy Services, Division of Radiation Oncology, Peter MacCallum Cancer Centre, Melbourne, Australia
| | - L Beaulieu
- Service de Physique Médicale et Radioprotection, et Axe Oncologie du Centre de Recherche du CHU de Québec, CHU de Québec, Québec, Canada; Département de Physique, de Génie Physique et d'Optique et Centre de Recherche sur le Cancer, Université Laval, Québec, Canada
| | - T Major
- Radiotherapy Centre, National Institute of Oncology, Budapest, Hungary; Department of Oncology, Semmelweis University, Budapest, Hungary
| | - T Kron
- Peter MacCallum Cancer Centre and Sir Peter MacCallum Department of Oncology, University of Melbourne, Melbourne, Australia; Centre for Medical Radiation Physics, University of Wollongong, Wollongong, Australia
| |
Collapse
|
3
|
Major T, Fröhlich G, Ágoston P, Polgár C, Takácsi-Nagy Z. The value of brachytherapy in the age of advanced external beam radiotherapy: a review of the literature in terms of dosimetry. Strahlenther Onkol 2021; 198:93-109. [PMID: 34724086 PMCID: PMC8789711 DOI: 10.1007/s00066-021-01867-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2021] [Accepted: 10/03/2021] [Indexed: 12/29/2022]
Abstract
Brachytherapy (BT) has long been used for successful treatment of various tumour entities, including prostate, breast and gynaecological cancer. However, particularly due to advances in modern external beam techniques such as intensity-modulated radiotherapy (IMRT), volume modulated arc therapy (VMAT) and stereotactic body radiotherapy (SBRT), there are concerns about its future. Based on a comprehensive literature review, this article aims to summarize the role of BT in cancer treatment and highlight its particular dosimetric advantages. The authors conclude that image-guided BT supported by inverse dose planning will successfully compete with high-tech EBRT in the future and continue to serve as a valuable modality for cancer treatment.
Collapse
Affiliation(s)
- Tibor Major
- Radiotherapy Centre, National Institute of Oncology, Budapest, Hungary. .,Department of Oncology, Semmelweis University, Budapest, Hungary.
| | - Georgina Fröhlich
- Radiotherapy Centre, National Institute of Oncology, Budapest, Hungary.,Faculty of Science, Eötvös Loránd University, Budapest, Hungary
| | - Péter Ágoston
- Radiotherapy Centre, National Institute of Oncology, Budapest, Hungary.,Department of Oncology, Semmelweis University, Budapest, Hungary
| | - Csaba Polgár
- Radiotherapy Centre, National Institute of Oncology, Budapest, Hungary.,Department of Oncology, Semmelweis University, Budapest, Hungary
| | - Zoltán Takácsi-Nagy
- Radiotherapy Centre, National Institute of Oncology, Budapest, Hungary.,Department of Oncology, Semmelweis University, Budapest, Hungary
| |
Collapse
|
4
|
Multicatheter interstitial brachytherapy versus stereotactic radiotherapy with CyberKnife for accelerated partial breast irradiation: a comparative treatment planning study with respect to dosimetry of organs at risk. Radiol Oncol 2021; 55:229-239. [PMID: 33768766 PMCID: PMC8042824 DOI: 10.2478/raon-2021-0016] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2020] [Accepted: 02/02/2021] [Indexed: 01/02/2023] Open
Abstract
Background The aim of the study was to dosimetrically compare multicatheter interstitial brachytherapy (MIBT) and stereotactic radiotherapy with CyberKnife (CK) for accelerated partial breast irradiation (APBI) especially concerning the dose of organs at risk (OAR-s). Patients and methods Treatment plans of thirty-two MIBT and CK patients were compared. The OAR-s included ipsilateral non-target and contralateral breast, ipsilateral and contralateral lung, skin, ribs, and heart for left-sided cases. The fractionation was identical (4 x 6.25 Gy) in both treatment groups. The relative volumes (e.g. V100, V90) receiving a given relative dose (100%, 90%), and the relative doses (e.g. D0.1cm3, D1cm3) delivered to the most exposed small volumes (0.1 cm3, 1 cm3) were calculated from dose-volume histograms. All dose values were related to the prescribed dose (25 Gy). Results Regarding non-target breast CK performed slightly better than MIBT (V100: 0.7% vs. 1.6%, V50: 10.5% vs. 12.9%). The mean dose of the ipsilateral lung was the same for both techniques (4.9%), but doses irradiated to volume of 1 cm3 were lower with MIBT (36.1% vs. 45.4%). Protection of skin and rib was better with MIBT. There were no significant differences between the dose-volume parameters of the heart, but with MIBT, slightly larger volumes were irradiated by 5% dose (V5: 29.9% vs. 21.2%). Contralateral breast and lung received a somewhat higher dose with MIBT (D1cm3: 2.6% vs. 1.8% and 3.6% vs. 2.5%). Conclusions The target volume can be properly irradiated by both techniques with similar dose distributions and high dose conformity. Regarding the dose to the non-target breast, heart, and contralateral organs the CK was superior, but the nearby organs (skin, ribs, ipsilateral lung) received less dose with MIBT. The observed dosimetric differences were small but significant in a few parameters at the examined patient number. More studies are needed to explore whether these dosimetric findings have clinical significance.
Collapse
|
5
|
Biological dose summation of external beam radiotherapy for the whole breast and image-guided high-dose-rate interstitial brachytherapy boost in early-stage breast cancer. J Contemp Brachytherapy 2020; 12:462-469. [PMID: 33299435 PMCID: PMC7701920 DOI: 10.5114/jcb.2020.100379] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2020] [Accepted: 08/25/2020] [Indexed: 11/17/2022] Open
Abstract
Purpose To develop an alternative method for summing biologically effective doses of external beam radiotherapy (EBRT) with interstitial high-dose-rate (HDR) brachytherapy (BT) boost in breast cancer. The total doses using EBRT boost were compared with BT boost using our method. Material and methods Twenty-four EBRT plus interstitial HDR-BT plans were selected, and additional plans using EBRT boost were created. The prescribed dose was 2.67/40.05 Gy to whole breast and 4.75/14.25 Gy BT or 2.67/10.7 Gy EBRT to planning target volume (PTV) boost. EBRT and BT computed tomography (CT) were registered twice, including fitting the target volumes and using the lung, and the most exposed volume of critical organs in BT were identified on EBRT CT images. The minimal dose of these from EBRT was summed with their BT dose, and these EQD2 doses were compared using BT vs. EBRT boost. This method was compared with uniform dose conception (UDC). Results D90 of PTV boost was significantly higher with BT than with EBRT boost: 67.1 Gy vs. 56.7 Gy, p = 0.0001. There was no significant difference in the dose of non-target and contralateral breast using BT and EBRT boost. D1 to skin, lung, and D0.1 to heart were 58.6 Gy vs. 66.7 Gy (p = 0.0025), 32.6 Gy vs. 50.6 Gy (p = 0.0002), and 52.2 Gy vs. 58.1 Gy (p = 0.0009), respectively, while D0.1 to ribs was 44.3 Gy vs. 37.7 Gy (p = 0.0062). UDC overestimated D1 (lung) by 54% (p = 0.0001) and D1 (ribs) by 28% (p = 0.0003). Conclusions Based on our biological dose summation method, the total dose of PTV in the breast is higher using BT boost than with EBRT. BT boost yields lower skin, lung, and heart doses, but higher dose to ribs. UDC overestimates lung and ribs doses.
Collapse
|
6
|
Fröhlich G, Mészáros N, Smanykó V, Stelczer G, Herein A, Polgár C, Major T. Is stereotactic CyberKnife radiotherapy or multicatheter HDR brachytherapy the better option dosimetrically for accelerated partial breast irradiation? Brachytherapy 2020; 20:326-331. [PMID: 33221260 DOI: 10.1016/j.brachy.2020.10.003] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2020] [Revised: 10/08/2020] [Accepted: 10/13/2020] [Indexed: 02/08/2023]
Abstract
OBJECTIVE To compare dosimetrically the stereotactic CyberKnife (CK) therapy and multicatheter high-dose-rate (HDR) brachytherapy (BT) for accelerated partial breast irradiation (APBI). METHODS Treatment plans of 25 patients treated with CK were selected, and additional plans using multicatheter HDR BT were created on the same CT images. The prescribed dose was 6.25/25 Gy in both plans to the target volume (PTV). The dose-volume parameters were calculated for both techniques and compared. RESULTS The D90 total dose of the PTV was significantly lower with CK than with HDR BT, D90 was 25.7 Gy, and 27.0 Gy (p < 0.001). However, CK plans were more conformal than BT, COIN was 0.87, and 0.81 (p = 0.0030). The V50 of the non-target breast was higher with CK than with BT: 10.5% and 3.3% (p = 0.0010), while there was no difference in the dose of the contralateral breast and contralateral lung. Dose to skin, ipsilateral lung, and ribs were higher with CK than with BT: D1 was 20.6 Gy vs. 11.5 Gy (p = 0.0018) to skin, 11.4 Gy vs. 9.6 Gy (p = 0.0272) to ipsilateral lung and 18.5 Gy vs. 12.3 Gy (p = 0.0013) to ribs, while D0.1 to heart was lower, 3.0 Gy vs. 3.2 Gy (p = 0.0476), respectively. CONCLUSIONS Multicatheter HDR BT yields more advantageous plans than stereotactic CyberKnife treatment in accelerated partial breast irradiation, except in terms of dose conformality and the dose to the heart. There was no difference in the dose of the contralateral breast and lung.
Collapse
Affiliation(s)
- Georgina Fröhlich
- National Institute of Oncology, Centre of Radiotherapy, Budapest, Hungary; Department of Biophysics, Eötvös Loránd University, Faculty of Science, Budapest, Hungary.
| | - Norbert Mészáros
- National Institute of Oncology, Centre of Radiotherapy, Budapest, Hungary; Department of Oncology, Faculty of Medicine, Semmelweis University, Budapest, Hungary
| | - Viktor Smanykó
- National Institute of Oncology, Centre of Radiotherapy, Budapest, Hungary
| | - Gábor Stelczer
- National Institute of Oncology, Centre of Radiotherapy, Budapest, Hungary
| | - András Herein
- National Institute of Oncology, Centre of Radiotherapy, Budapest, Hungary
| | - Csaba Polgár
- National Institute of Oncology, Centre of Radiotherapy, Budapest, Hungary; Department of Oncology, Faculty of Medicine, Semmelweis University, Budapest, Hungary
| | - Tibor Major
- National Institute of Oncology, Centre of Radiotherapy, Budapest, Hungary; Department of Oncology, Faculty of Medicine, Semmelweis University, Budapest, Hungary
| |
Collapse
|