Haefeli PC, Zwahlen ZM, Baumgärtner R, Link BC, Beck M. RM Pressfit vitamys: the 10-year follow-up. Hip Int 2025; 35:142-149. [PMID: 39772936 DOI: 10.1177/11207000241304659] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/11/2025]
Abstract
INTRODUCTION The RM Pressfit vitamys is an uncemented, titanium particle-coated, isoelastic monoblock cup made of vitamin E blended highly cross-linked polyethylene. We addressed the following questions: (1) What are the clinical and (2) radiographic outcomes 10 years after implantation? (3) What is the revision rate? METHODS In this prospective observational study in a tertiary care centre we investigated all consecutive cases of total hip replacement with the RM Pressfit vitamys cup between September 2009 and November 2011. It was implanted in 162 hips, 49.4% in women. The mean age was 67.2 years (standard deviation [SD] 9.5), and the mean BMI was 27.3 kg/m2 (SD 4.7). In 153 cases (94.4%), primary or secondary osteoarthritis was the diagnosis. We evaluated preoperative and follow-up data at 6 weeks, 1, 5, and 10 years. A modified Harris Hip Score (mHHS), pain and satisfaction on a visual analogue scale (VAS), radiographic evaluation, complications and revision rate were investigated. RESULTS At the 10-year follow-up (mean 120.5 months, SD 1.4, range 118-126), 99 hips were available for clinical and radiographic evaluation. (1) The mean mHHS was 94.8 (SD 9.9), rest pain 0.2 (SD 0.6), load pain 0.5 (SD 1.5), and satisfaction 9.5 (SD 1.1). The mean improvement as compared to preoperatively was +33.7 (SD 16.8), -3.3 (SD 2.7), -6.0 (SD 2.4) and +5.7 (SD 2.5), respectively. (2) In the radiographic evaluation, no loose cups, no acetabular lucent lines, or acetabular osteolysis were seen. (3) 2 cups were revised, both due to malpositioning. The 10-year cumulative revision rate was 2.0% (95%CI, 0.0-4.2%). The implant survival rate with aseptic loosening as endpoint was 100%. No adverse events were reported. CONCLUSIONS At the 10-year follow-up, the RM Pressfit vitamys cup still had promising results with good clinical and radiographic outcomes and a low revision rate.
Collapse
Affiliation(s)
- Pascal C Haefeli
- Department of Orthopaedic and Trauma Surgery, Lucerne Cantonal Hospital, Spitalstrasse, Lucerne, Switzerland
| | - Zinedine M Zwahlen
- Department of Orthopaedic and Trauma Surgery, Lucerne Cantonal Hospital, Spitalstrasse, Lucerne, Switzerland
| | - Ralf Baumgärtner
- Department of Orthopaedic and Trauma Surgery, Lucerne Cantonal Hospital, Spitalstrasse, Lucerne, Switzerland
| | - Björn-Christian Link
- Department of Orthopaedic and Trauma Surgery, Lucerne Cantonal Hospital, Spitalstrasse, Lucerne, Switzerland
| | - Martin Beck
- Orthopaedic Clinic Lucerne, Lucerne, Switzerland
| |
Collapse
|
2
|
Portet A, Besnard M, Ratsimbazafy C, Berhouet J, Samargandi R, Le Nail LR. The RM Press fit cup™: an investigation in 182 hips at ten-year follow-up. Orthop Traumatol Surg Res 2024:103988. [PMID: 39245266 DOI: 10.1016/j.otsr.2024.103988] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/05/2024] [Revised: 08/04/2024] [Accepted: 09/05/2024] [Indexed: 09/10/2024]
Abstract
INTRODUCTION For over 10 years, the RM Pressfit cup™ has been used in our department. This is a one-piece, elastic, cementless implant designed with standard polyethylene (PE), covered with a thin coating of titanium particles. To date, there is no French study evaluating this cup after more than 10 years. Therefore, we conducted a retrospective study in order to: (1) evaluate the survival of the implant with a minimum follow-up of 10 years, (2) evaluate the functional scores at the last follow-up, (3) measure the wear of the PE, (4) identify radiological loosening, (5) search for risk factors for cup removal, (6) identify complications that required management in the operating theatre. HYPOTHESIS The working hypothesis was that the survival of this implant was greater than 95% at 10 years' follow-up, in accordance with the criteria of the National Institute for Health and Care Excellence (NICE). MATERIALS AND METHODS This was a retrospective monocentric study, including adult patients who underwent total hip arthroplasty (THA) with an RM Pressfit cup™ (28 mm friction size) for coxarthrosis (primary or secondary) or femoral head osteonecrosis. Exclusion criteria were a follow-up period of less than 10 years, the placement of an RM Pressfit cup™ as a secondary intention for a THA (n = 5) or following a trochanteric fracture (n = 1). In total, 163 patients (182 hips) with a median age (Q1-Q3) of 63 (56-68) years, and a sex ratio (M/F) of 1.7 were included. Functional scores were evaluated using the Harris and Oxford scores. Radiographs were analyzed in the immediate postoperative period and at the last follow-up. RESULTS The median follow-up was 10.5 (10-11.5) years. Of the 182 included hips, 7 cups were removed, corresponding to a 10-year survival rate of 96.1% (95% CI [93.3; 96.9]). The median Harris and Oxford scores at 10.5 years were 95 (90-98) and 19 (17-23) points, respectively. The median PE wear rate was 0.058 (0.039-0.087) mm/year. Univariate analysis showed that male gender was associated with PE wear (OR = 3.6; 95% CI [1.3; 12.9] [p = 0.012]). Ten cups (6%) showed radiological instability with migration greater than 3 mm and/or variation in inclination greater than 8 °, and only 9 hips (6%) showed bone resorption. No preoperative or perioperative factors analyzed were associated with cup removal. Dislocation accounted for 71% (n = 5) of the causes of cup removal. Additionally, 6 hips experienced at least one dislocation episode requiring reduction by external maneuvers in the operating room, bringing the overall dislocation rate in the series to 6% (n = 11). Increased cup inclination was the only risk factor for prosthetic dislocation (OR = 1.2; 95% CI [1.09; 1.4] [p = 0.0003]). Overall complications requiring surgical intervention included 15 (8.3%) implanted cups (7 removed cups, 6 dislocation episodes requiring reduction by external maneuvers in the operating room, and 2 hips reoperated for washing and changing of mobile components due to early infection). CONCLUSION The RM Pressfit cup™ gives good long-term clinical and radiological results with an overall survival of 96.1% and a low complication rate over 10 years. Over the last 2 years the RM Vitamys™ cup has been introduced allowing the use of 32 mm femoral head diameter for size 48 cups, to reduce the risk of dislocation. LEVEL OF EVIDENCE IV; retrospective cohort.
Collapse
Affiliation(s)
- Adrien Portet
- Service de Chirurgie Orthopédique, Hôpital Trousseau, CHRU de Tours, Avenue de la République, Chambray-lès-Tours, Tours Cedex 9, 37044, France.
| | - Marion Besnard
- Centre Hospitalier Intercommunal Amboise-Château-Renault, Hôpital Robert-Debré, rue des Ursulines, BP 329, 37403 Amboise Cedex, France
| | - Carole Ratsimbazafy
- Hôpital Saint-Antoine, Pharmacie, GHU AP-HP Sorbonne Université 184 rue du Faubourg-Saint-Antoine, 75012 Paris, France
| | - Julien Berhouet
- Service de Chirurgie Orthopédique, Hôpital Trousseau, CHRU de Tours, Avenue de la République, Chambray-lès-Tours, Tours Cedex 9, 37044, France
| | - Ramy Samargandi
- Service de Chirurgie Orthopédique, Hôpital Trousseau, CHRU de Tours, Avenue de la République, Chambray-lès-Tours, Tours Cedex 9, 37044, France; Department of Orthopedic Surgery, Faculty of Medicine, University of Jeddah, Jeddah, Saudi Arabia
| | - Louis-Romée Le Nail
- Service de Chirurgie Orthopédique, Hôpital Trousseau, CHRU de Tours, Avenue de la République, Chambray-lès-Tours, Tours Cedex 9, 37044, France
| |
Collapse
|
3
|
Ramsodit KR, Sierevelt IN, Janssen ERC, Kaarsemaker S, Haverkamp D. Mid-term clinical outcomes of the uncemented Robert Mathys pressfit cup. World J Clin Cases 2024; 12:3684-3691. [PMID: 38994294 PMCID: PMC11235464 DOI: 10.12998/wjcc.v12.i19.3684] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/22/2023] [Revised: 04/25/2024] [Accepted: 05/16/2024] [Indexed: 06/29/2024] Open
Abstract
BACKGROUND The use of uncemented cups during total hip arthroplasty (THA) has gained popularity in recent years. The Robert Mathys (RM) pressfit cup, an uncemented monoblock implant is expected to preserve bone density due to its composition and external surface, while reducing backside wear with its monoblock construction. These factors should lead to a high survival rate of the implant. AIM To evaluate the mid-term survival and functional outcome of the RM Pressfit cup in a large study population. METHODS Between 2011 and 2020, we included 1324 patients receiving a primary THA using the RM pressfit cup. Final clinical follow-up was performed at 2 years postoperatively with the Dutch arthroplasty register used to assess implant status thereafter. Revision for acetabular failure and reason for revision were reported to evaluate implant survival, while the hip disability and osteoarthritis outcome score (HOOS) scores were used to assess functional outcome. RESULTS The mean age at surgery was 64.9 years. The mean follow-up was 4.6 years. Of the 1324 THAs performed, 13 needed cup revisions within 5 years after index THA: 5 due to aseptic loosening, 6 due to infection, 2 due to dislocation and 2 due to other causes. This resulted in a 5-year cup survival of 98.8% (95%CI: 98.1-99.5). Nine of the cup revisions occurred within the first year after index THA. HOOS scores increased significantly in all domains during the first year and levelled out during the second year. CONCLUSION In the present study, the RM pressfit cup demonstrated excellent clinical outcomes at mid-term follow-up; however, future studies are needed to assess the long-term outcomes of this acetabular implant.
Collapse
Affiliation(s)
- Kishan Ritek Ramsodit
- Department of Orthopedic Surgery, Xpert Clinics Amsterdam, Amsterdam 1101EA, North-Holland, Netherlands
| | - Inger N Sierevelt
- Department of Orthopedic Surgery, Xpert Clinics Amsterdam, Amsterdam 1101EA, North-Holland, Netherlands
- Department of Orthopedic, Spaarne Gasthuis Academy, Hoofddorp 2134 TM, Netherlands
| | - Esther R C Janssen
- Department of Orthopaedic Surgery, Viecuri Medical Centre, Venlo 5912 BL, Netherlands
| | - Sjoerd Kaarsemaker
- Department of Orthopaedic Surgery, Viecuri Medisch Centrum, Venlo 5912 BL, Netherlands
| | - Daniël Haverkamp
- Department of Orthopedic Surgery, Xpert Clinics Amsterdam, Amsterdam 1101EA, North-Holland, Netherlands
| |
Collapse
|
4
|
Foxall-Smith M, Wyatt MC, Frampton C, Kieser D, Hooper G. The 45-year evolution of the Mathys RM monoblock cups: have the paradigm shifts been worthwhile? Hip Int 2023; 33:193-202. [PMID: 35438033 DOI: 10.1177/11207000211067507] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
INTRODUCTION The Robert Mathys (RM) monoblock uncemented cup is a design less commonly used in primary total hip replacement. It's purported advantages over modular cemented cups are: (1) its modulus of elasticity approximating bone, thus mimicking load transmission and the biomechanical behaviour of the cup to better match stresses on the acetabulum, leading to bone-preservation; and (2) as a 1-piece cup there is absence of a mobile interface between a liner and shell, preventing backside wear. Since its inception in 1983 there have been 3 major design changes: the RM Classic, the RM Pressfit, and the RM Vitamys with the most modern polyethylene (vitamin E). METHODS In a retrospective cohort study of the New Zealand Joint Registry, all designs of RM acetabular cup were reviewed. Data were included from1998 to 2018. All-cause revision rates, reasons for revision and the Oxford Hip Score (OHS) were assessed. RESULTS In total 13,272 acetabular cups were included. The all-cause revision rates did not differ between the designs. Revision rates for aseptic loosening in the RM Vitamys were lower, but the follow-up was shorter and more larger heads were used. There was no difference in the OHS. CONCLUSION All implant designs were safe. The use of larger heads led to a decrease in revisions due to dislocation. It has to be waited out whether the RM Vitamys performs superior in the long-term due to the highly cross-linked polyethylene.
Collapse
Affiliation(s)
| | - Michael C Wyatt
- Department of Trauma and Orthopaedic Surgery, Palmerston North Hospital, Massey University, Manawatu, New Zealand
| | - Christopher Frampton
- Department of Surgery and Musculoskeletal Medicine, University of Otago, New Zealand
| | - David Kieser
- Department of Surgery and Musculoskeletal Medicine, University of Otago, New Zealand
| | - Gary Hooper
- Department of Surgery and Musculoskeletal Medicine, University of Otago, New Zealand
| |
Collapse
|
5
|
Brodt S, Jacob B, Nowack D, Zippelius T, Strube P, Matziolis G. An Isoelastic Monoblock Cup Retains More Acetabular and Femoral Bone Than a Modular Press-Fit Cup: A Prospective Randomized Controlled Trial. J Bone Joint Surg Am 2021; 103:992-999. [PMID: 33617161 DOI: 10.2106/jbjs.19.00787] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND For cup revision after total hip arthroplasty, sufficiently good periacetabular bone stock is a prerequisite for fixation of the revision implant. Cementless cups can lead to a relevant reduction of peri-implant bone mineral density (BMD) through stress-shielding. METHODS Fifty patients were included in this prospective randomized controlled trial. Group 1 (RM group) received an isoelastic monoblock cup (RM Pressfit vitamys; Mathys). Group 2 (IT group) received a modular titanium cup (Allofit-S IT Alloclassic with a polyethylene liner; Zimmer). Periacetabular BMD was determined and subdivided into 4 regions of interest by dual x-ray absorptiometry at 1 week (baseline) and at 4 years postoperatively. Our primary outcome was reduction in periacetabular BMD. RESULTS Periacetabular BMD was reduced by an average of 15.1% in the RM group and 16.5% in the IT group at 4 years postoperatively. No significant difference was found between the 2 groups over the periacetabular structure as a whole. However, the decrease of BMD in the polar region was significantly different in the RM group (4.9% ± 10.0%) compared with the IT group (15.9% ± 14.9%, p = 0.005). Use of the isoelastic RM cup showed significantly less bone loss than the modular IT cup. CONCLUSIONS Relevant loss of BMD at 4 years after surgery was identified in the periacetabular region in both groups. No differences between the 2 cup systems were found when looking at the overall periacetabular region. As a secondary outcome, less postoperative periacetabular bone loss occurred in the polar region when an isoelastic cup was used. Longer follow-up is required to allow for conclusions to be drawn about the long-term course of the 2 cup systems. LEVEL OF EVIDENCE Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Steffen Brodt
- Department of Orthopedics, Jena University Hospital, Campus Eisenberg, Germany
| | | | | | | | | | | |
Collapse
|
6
|
Young PS, Macarico DT, Silverwood RK, Farhan-Alanie OM, Mohammed A, Periasamy K, Nicol A, Meek RMD. Anatomical pelvic loading of a monoblock polyethylene acetabular component. Bone Joint J 2021; 103-B:872-880. [PMID: 33934654 DOI: 10.1302/0301-620x.103b5.bjj-2020-1321.r2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS Uncemented metal acetabular components show good osseointegration, but material stiffness causes stress shielding and retroacetabular bone loss. Cemented monoblock polyethylene components load more physiologically; however, the cement bone interface can suffer fibrous encapsulation and loosening. It was hypothesized that an uncemented titanium-sintered monoblock polyethylene component may offer the optimum combination of osseointegration and anatomical loading. METHODS A total of 38 patients were prospectively enrolled and received an uncemented monoblock polyethylene acetabular (pressfit) component. This single cohort was then retrospectively compared with previously reported randomized cohorts of cemented monoblock (cemented) and trabecular metal (trabecular) acetabular implants. The primary outcome measure was periprosthetic bone density using dual-energy x-ray absorptiometry over two years. Secondary outcomes included radiological and clinical analysis. RESULTS Although there were differences in the number of males and females in each group, no significant sex bias was noted (p = 0.080). Furthermore, there was no significant difference in age (p = 0.910) or baseline lumbar bone mineral density (BMD) (p = 0.998) found between any of the groups (pressfit, cemented, or trabecular). The pressfit implant initially behaved like the trabecular component with an immediate fall in BMD in the inferior and medial regions, with preserved BMD laterally, suggesting lateral rim loading. However, the pressfit component subsequently showed a reversal in BMD medially with recovery back towards baseline, and a continued rise in lateral BMD. This would suggest that the pressfit component begins to reload the medial bone over time, more akin to the cemented component. Analysis of postoperative radiographs revealed no pressfit component subsidence or movement up to two years postoperatively (100% interobserver reliability). Medial defects seen immediately postoperatively in five cases had completely resolved by two years in four patients. CONCLUSION Initially, the uncemented monoblock component behaved similarly to the rigid trabecular metal component with lateral rim loading; however, over two years this changed to more closely resemble the loading pattern of a cemented polyethylene component with increasing medial pelvic loading. This indicates that the uncemented monoblock acetabular component may result in optimized fixation and preservation of retroacetabular bone stock. Cite this article: Bone Joint J 2021;103-B(5):872-880.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Alice Nicol
- Department of Nuclear Medicine, Queen Elizabeth University Hospital, Glasgow, UK
| | - R M Dominic Meek
- Department of Orthopaedics, Queen Elizabeth University Hospital, Glasgow, UK
| |
Collapse
|
7
|
Mahmood FF, Beck M, de Gast A, Rehbein P, French GJ, Becker R, Dominkus M, Helmy N, Hollmann L, Baines J. Survivorship and Patient-Reported Outcomes of an Uncemented Vitamin E-Infused Monoblock Acetabular Cup: A Multicenter Prospective Cohort Study. J Arthroplasty 2021; 36:1700-1706. [PMID: 33516632 DOI: 10.1016/j.arth.2020.12.032] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/03/2020] [Revised: 12/16/2020] [Accepted: 12/18/2020] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Addition of vitamin E to polyethylene is theorized to reduce the potential for oxidative wear in acetabular components. This paper presents a multicenter prospective cohort study that reports on outcomes from use of a Vitamin E-infused highly cross-linked polyethylene acetabular cup. METHODS Patients were recruited across nine medical institutions. Clinical outcome measures recorded were the Harris Hip Score, visual analogue score for pain and satisfaction. Evidence of implant loosening or osteolysis was collected radiologically. Cup survival and reasons for revision in relevant cases were also recorded. Data collection was undertaken preoperatively, at 6-12 weeks, 6 months, 1 year, 2 years, and 5 years. A total of 675 patients were recruited, with 450 cases available at final review. Data regarding cup survival was available to 8 years and 9 months postoperatively. RESULTS Improvements in both the Harris Hip Score and visual analogue score for pain and satisfaction were recorded at all time points, with these being maintained through the length of follow-up. In total, 89% of cups were implanted within the Lewinnek safe zone. A lucent line was identified in one case, with no evidence of acetabular osteolysis observed throughout the follow-up period. Cup survival was 98.9% at 8 years and 9 months. No revisions for aseptic loosening were observed. CONCLUSIONS The use of a vitamin E-infused polyethylene acetabular cup demonstrates reassuring patient-reported outcomes, radiological measures, and cup survival at medium to long-term follow-up.
Collapse
Affiliation(s)
- Fahd F Mahmood
- Department of Orthopaedics, Golden Jubilee National Hospital, Clydebank, UK
| | - Martin Beck
- Luzerner Kantonsspital, Luzern, Switzerland; Orthopaedic Clinic Lucerne, Hirslanden Clinic St. Anna, Lucerne
| | - Arthur de Gast
- Diakonessenhuis Utrecht, Utrecht, the Netherlands; Clinical Orthopedic Research Center Midden-Nederland, Diakonessenhuis Zeist, Zeist, the Netherlands
| | - Philipp Rehbein
- Department of Orthopaedics, St. Josefs-Hospital Wiesbaden, Wiesbaden, Germany
| | | | - Roland Becker
- Dept. of Orthopedics and Traumatology, Brandenburg Medical School, Brandenburg, Germany
| | - Martin Dominkus
- Orthopaedic Department, Orthopädisches Spital Speising, Wien, Austria; Sigmund Freud University, Campus Prater Freudplatz 1, Wien, Austria
| | - Naeder Helmy
- Department of Orthopaedics, Nurgerspital Solothurn, Solothurn, Switzerland
| | - Lutz Hollmann
- Streekziekenhuis Koningin Beatrix, Winterswijk, the Netherlands
| | - Joe Baines
- Department of Orthopaedics, Golden Jubilee National Hospital, Clydebank, UK
| |
Collapse
|
8
|
Erivan R, Villatte G, Millerioux S, Mulliez A, Descamps S, Boisgard S. Survival at 11 to 21 years for 779 Metasul® metal-on-metal total hip arthroplasties. J Orthop Surg (Hong Kong) 2021; 28:2309499020926265. [PMID: 32735149 DOI: 10.1177/2309499020926265] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
Abstract
BACKGROUND Total hip arthroplasties (THAs) bearing is one of the most important factors for hip replacement because THA survival depends on it. Metal-on-metal (MoM) bearing has lower wear than metal-on-polyethylene but lot of aseptic loosening decrease utilization. We analyze the survival rate of 28 mm Metasul® bearings after a mean follow-up of 12.9 years. METHODS The main objective of this study was to evaluate the survival of the MoM. We evaluate 779 consecutive THAs performed between January 1995 and December 2005 for primary osteoarthritis, congenital dysplasia classified Crowe I, or rheumatoid arthritis. Survival rate was calculated by the Kaplan-Meir method. The association between survival and age, gender, body mass index (BMI), and surface coating was investigated with a proportional odds model. The clinical assessment included Oxford score. RESULTS Six hundred fifty-two THAs were reviewed. Sixty-two revisions (9.5%) were performed including 34 aseptic loosening and 11 deep infections. The survival for prosthesis with any reason at 20 years was 87% (confidence interval (CI) 83-90.2) for aseptic loosening at 20 years was 90.1% (CI 87-93.8). There was no association with age, BMI, and surface coating. Gender was significant with lower aseptic loosening for men, hazard ratio = 0.45, p value = 0.035. Oxford score was 57 ± 6.7 (19-60). CONCLUSION The survival rate of Metasul was well and seems to be like our clinical finding. However, radiographic aseptic loosening without surgery is not included in the survival rate. The Oxford score was very good with a lot of patients with asymptomatic hip. LEVEL OF EVIDENCE Level IV/Retrospective study.
Collapse
Affiliation(s)
- Roger Erivan
- Université Clermont Auvergne, CHU Clermont-Ferrand, CNRS, SIGMA Clermont, ICCF, Clermont-Ferrand, France
| | - Guillaume Villatte
- Université Clermont Auvergne, CHU Clermont-Ferrand, CNRS, SIGMA Clermont, ICCF, Clermont-Ferrand, France
| | - Stéphane Millerioux
- Université Clermont Auvergne, CHU Clermont-Ferrand, Clermont-Ferrand, France
| | - Aurélien Mulliez
- Délégation à la Recherche Clinique et aux Innovations (DRCI) - CHU Clermont-Ferrand, Clermont-Ferrand, France
| | - Stéphane Descamps
- Université Clermont Auvergne, CHU Clermont-Ferrand, CNRS, SIGMA Clermont, ICCF, Clermont-Ferrand, France
| | - Stéphane Boisgard
- Université Clermont Auvergne, CHU Clermont-Ferrand, CNRS, SIGMA Clermont, ICCF, Clermont-Ferrand, France
| |
Collapse
|
9
|
Afghanyar Y, Joser S, Tecle J, Drees P, Dargel J, Rehbein P, Kutzner KP. The concept of a cementless isoelastic monoblock cup made of highly cross-linked polyethylene infused with vitamin E: radiological analyses of migration and wear using EBRA and clinical outcomes at mid-term follow-up. BMC Musculoskelet Disord 2021; 22:107. [PMID: 33485345 PMCID: PMC7827971 DOI: 10.1186/s12891-021-03981-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/02/2020] [Accepted: 01/17/2021] [Indexed: 11/10/2022] Open
Abstract
Background The newest generation of cementless titanium-coated, isoelastic monoblock cup with vitamin E-blended highly cross-linked polyethylene (HXLPE) was introduced to the market in 2009. The aim of the present study was to obtain mid-term follow-up data including migration and wear analyses. Methods This prospective study investigated 101 primary total hip arthroplasty (THA) cases in 96 patients treated at a single institution. Patients were allowed full weight-bearing on the first day postoperatively. Harris hip score (HHS) and pain and satisfication on a visual analogue scale (VAS) were assessed at a mean follow-up of 79.0 months. Migration and wear were assessed using Einzel-Bild-Roentgen-Analyse (EBRA) software. Radiological acetabular bone alterations and complications were documented. Results At mid-term follow-up (mean 79.0 months, range: 51.8–101.7), 81 cases with complete clinical and radiological data were analyzed. Utilisable EBRA measurements were obtained for 42 hips. The mean HHS was 91.1 (range 38.0–100.0), VAS satisfaction was 9.6 (range 6.0–10.0), VAS rest pain was 0.2 (range 0.0–4.0), and VAS load pain was 0.6 (range 0.0–9.0). Mean migration was 0.86 mm (range: 0.0–2.56) at 24 months and 1.34 mm (range: 0.09–3.14) at 5 years, and the mean annual migration rate was 0.22 (range: − 0.24–1.34). The mean total wear was 0.4 mm (range: 0.03–1.0), corresponding to a mean annual wear rate of 0.06 mm per year (range: 0.0–0.17). Radiographic analysis did not reveal any cases of osteolysis, and no revision surgeries had to be performed. Conclusions After using vitamin-E blended HXLPE in cementless isoelastic monoblock cups, there were no obvious signs of osteolysis or aseptic loosening occurred. No patients required revision surgery after mid-term follow-up. Cup migration and wear values were well below the benchmarks considered predictive for potential future failure. Trial registration The trial registration number on ClinicalTrials.gov: NCT04322916 (retrospectively registered at 26.03.2020). Supplementary Information The online version contains supplementary material available at 10.1186/s12891-021-03981-8.
Collapse
Affiliation(s)
- Yama Afghanyar
- Department of Orthopaedic Surgery, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany.
| | - Sebastian Joser
- Department of Orthopaedic Surgery, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany
| | - Jonas Tecle
- Department of Orthopaedic Surgery, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany
| | - Philipp Drees
- Department of Orthopaedics and Traumatology, University Medical Centre of the Johannes Gutenberg-University of Mainz, Langenbeckstraße 1, 55131, Mainz, Germany
| | - Jens Dargel
- Department of Orthopaedic Surgery, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany
| | - Philipp Rehbein
- Department of Orthopaedic Surgery, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany
| | - Karl Philipp Kutzner
- Department of Orthopaedic Surgery, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany.,Department of Orthopaedics and Traumatology, University Medical Centre of the Johannes Gutenberg-University of Mainz, Langenbeckstraße 1, 55131, Mainz, Germany
| |
Collapse
|
10
|
Coupry A, Rony L, Ducellier F, Hubert L, Chappard D. Texture analysis of trabecular bone around RM-Pressfit cementless acetabulum in a series of 46 patients during a 5 year period. Orthop Traumatol Surg Res 2019; 105:1283-1287. [PMID: 31477444 DOI: 10.1016/j.otsr.2019.06.011] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/02/2019] [Revised: 05/27/2019] [Accepted: 06/06/2019] [Indexed: 02/02/2023]
Abstract
BACKGROUND Cementless total hip arthroplasty (THA) is a common procedure producing excellent clinical results. Their long-term survival is nevertheless burdened by loosening of the acetabular part caused by changes in the distribution of strains around the cup. In this context the RM-Pressfit® cup has been developed, resulting in a more harmonious distribution of the strains. HYPOTHESIS Texture analysis of X-ray films can evaluate the evolution of trabecular bone micro-architecture during the five years following THA with a RM-Pressfit® cup. MATERIAL AND METHOD A monocentric series of 46 hips was reviewed regularly within five years post- surgery. Radiographic evaluation of the operated hip was done on frontal digitized radiographs of the pelvis to follow evolution of bone micro-architecture in the #2 zone of De Lee and Charnley. Texture analysis using fractal algorithms was done at D0, 6 months, 1, 2 and 5 years post-THA. The fractal methods used included the skyscrapers and the dynamic blanket methods with 3 different structuring elements (a cross, a horizontal and a vertical vector). RESULTS The RM-Pressfit® caused significant changes in the distribution of strains around the acetabulum that preserved the bone volume over a 5-year period post-surgery. This corresponds to an improvement of the trabecular micro-architecture around the acetabular cups. CONCLUSION A statistically significant increase in the four fractal dimensions considered corresponded to an improved trabecular bone micro-architecture revealed by texture analysis, a non-invasive method that can be used on digitized X-ray images. LEVEL OF EVIDENCE IIIb, Case control study, retrospective design.
Collapse
Affiliation(s)
- Augustin Coupry
- Département de chirurgie osseuse, CHU-Angers, 49033 Angers, France
| | - Louis Rony
- Département de chirurgie osseuse, CHU-Angers, 49033 Angers, France; Groupe Etudes Remodelage Osseux et bioMatériaux, GEROM, EA-4658, SFR-4208, Univ-Angers, IRIS-IBS Institut de Biologie en Santé, CHU-Angers, 49933 Angers, France
| | | | - Laurent Hubert
- Département de chirurgie osseuse, CHU-Angers, 49033 Angers, France; Groupe Etudes Remodelage Osseux et bioMatériaux, GEROM, EA-4658, SFR-4208, Univ-Angers, IRIS-IBS Institut de Biologie en Santé, CHU-Angers, 49933 Angers, France
| | - Daniel Chappard
- Groupe Etudes Remodelage Osseux et bioMatériaux, GEROM, EA-4658, SFR-4208, Univ-Angers, IRIS-IBS Institut de Biologie en Santé, CHU-Angers, 49933 Angers, France.
| |
Collapse
|