1
|
Lawrence KW, Rajahraman V, Meftah M, Rozell JC, Schwarzkopf R, Arshi A. Patient-reported outcome differences for navigated and robot-assisted total hip arthroplasty frequently do not achieve clinically important differences: a systematic review. Hip Int 2024; 34:578-587. [PMID: 38566302 DOI: 10.1177/11207000241241797] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 04/04/2024]
Abstract
INTRODUCTION Total hip arthroplasty (THA) using computer-assisted navigation (N-THA) and robot-assisted surgery (RA-THA) has been increasingly adopted to improve implant positioning and offset/leg-length restoration. Whether clinically meaningful differences in patient-reported outcomes (PROMs) compared to conventional THA (C-THA) are achieved with intraoperative technology has not been established. This systematic review aimed to assess whether published relative PROM improvements with technology use in THA achieved minimal clinically important differences (MCIDs). METHODS PubMed/MEDLINE/Cochrane Library were systematically reviewed for studies comparing PROMs for primary N-THA or RA-THA with C-THA as the control group. Relative improvement differences between groups were compared to established MCID values. Reported clinical and radiographic differences were assessed. Review of N-THA and RA-THA literature yielded 6 (n = 2580) and 10 (n = 2786) studies, respectively, for analyses. RESULTS Statistically significant improvements in postoperative PROM scores were reported in 2/6 (33.3%) studies comparing N-THA with C-THA, though only 1 (16.7%) reported clinically significant relative improvements. Statistically significant improvements in postoperative PROMs were reported in 6/10 (60.0%) studies comparing RA-THA and C-THA, though none reported clinically significant relative improvements. Improved radiographic outcomes for N-THA and RA-THA were reported in 83.3% and 70.0% of studies, respectively. Only 1 study reported a significant improvement in revision rates with RA-THA as compared to C-THA. CONCLUSIONS Reported PROM scores in studies comparing N-THA or RA-THA to C-THA often do not achieve clinically significant relative improvements. Future studies reporting PROMs should be interpreted in the context of validated MCID values to accurately establish the clinical impact of intraoperative technology.
Collapse
Affiliation(s)
- Kyle W Lawrence
- Department of Orthopaedic Surgery, NYU Langone Health, New York, NY, USA
| | - Vinaya Rajahraman
- Department of Orthopaedic Surgery, NYU Langone Health, New York, NY, USA
| | - Morteza Meftah
- Department of Orthopaedic Surgery, NYU Langone Health, New York, NY, USA
| | - Joshua C Rozell
- Department of Orthopaedic Surgery, NYU Langone Health, New York, NY, USA
| | - Ran Schwarzkopf
- Department of Orthopaedic Surgery, NYU Langone Health, New York, NY, USA
| | - Armin Arshi
- Department of Orthopaedic Surgery, NYU Langone Health, New York, NY, USA
| |
Collapse
|
2
|
Nazmy H, Solitro G, Domb B, Amirouche F. Comparative Study of Alternative Methods for Measuring Leg Length Discrepancy after Robot-Assisted Total Hip Arthroplasty. Bioengineering (Basel) 2024; 11:853. [PMID: 39199810 PMCID: PMC11351844 DOI: 10.3390/bioengineering11080853] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2024] [Revised: 08/05/2024] [Accepted: 08/16/2024] [Indexed: 09/01/2024] Open
Abstract
BACKGROUND Our study addresses the lack of consensus on measuring leg length discrepancy (LLD) after total hip arthroplasty (THA). We will assess the inter-observer variability and correlation between the five most commonly used LLD methods and investigate the use of trigonometric principles in overcoming the limitations of current techniques. METHODS LLD was measured on postoperative AP pelvic radiographs using five conventional methods. CT images created a 3D computer model of the pelvis and femur. The resulting models were projected onto a 2D, used to measure LLD by the five methods. The measurements were evaluated via Taguchi analysis, a statistical method identifying the process's most influential factors. The approach was used to assess the new trigonometric method. RESULTS Conventional methods demonstrated poor correlation. Methods referenced to the centers of the femoral heads were insensitive to LLD originating outside the acetabular cup. Methods referencing either the inter-ischial line or the inter-obturator foramina to the lesser trochanter were sensitive to acetabular and femoral components. Trigonometry-based measurements showed a higher correlation. CONCLUSIONS Our results underscore clinicians' need to specify the methods used to assess LLD. Applying trigonometric principles was shown to be accurate and reliable, but it was contingent on proper radiographic alignment.
Collapse
Affiliation(s)
- Hamad Nazmy
- Department of Orthopaedic Surgery, University of Illinois at Chicago, Chicago, IL 60612, USA;
| | - Giovanni Solitro
- Department of Orthopaedics, LSU Health Shreveport, Shreveport, LA 71103, USA;
| | - Benjamin Domb
- American Hip Institute, 999 E. Touhy, Suite 450, Des Plaines, IL 60018, USA;
| | - Farid Amirouche
- Department of Orthopaedic Surgery, University of Illinois at Chicago, Chicago, IL 60612, USA;
- Orthopaedic and Spine Institute, Department of Orthopaedic Surgery, Northshore University Health System, an Affiliate of the University of Chicago Pritzker School of Medicine, 9669 Kenton Avenue, Skokie, IL 60076, USA
| |
Collapse
|
3
|
Cardenas JM, Gordon D, Waddell BS, Kitziger KJ, Peters PC, Gladnick BP. Does Artificial Intelligence Outperform Humans Using Fluoroscopic-Assisted Computer Navigation for Total Hip Arthroplasty? Arthroplast Today 2024; 27:101410. [PMID: 38840694 PMCID: PMC11150909 DOI: 10.1016/j.artd.2024.101410] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/23/2024] [Revised: 03/13/2024] [Accepted: 04/28/2024] [Indexed: 06/07/2024] Open
Abstract
Background Successful total hip arthroplasty (THA) relies on the correct implant position. THA accuracy can be improved with the use of intraoperative fluoroscopic-assisted computer navigation. Artificial intelligence (AI) software may enhance fluoroscopic navigation; however, the accuracy of the AI compared to human-controlled software in assessing acetabular component position and leg length discrepancy (LLD) has not been studied. Methods We analyzed 420 consecutive primary THAs performed by a single surgeon using fluoroscopic-assisted computer navigation software. The first cohort of 211 patients required inputs from a human technician (manual), while the second cohort of 209 patients used an automated version of the software controlled by AI. The intraoperative acetabular component placement (inclination and anteversion) and LLD were recorded and compared to the 2-week postoperative standing anterior-posterior pelvis radiograph. Results Ninety-four percent (199/211) of cups in the manual cohort and 95% (198/209) of cups in the AI cohort were within the Lewinnek "safe-zone" (P = 1.0). In the manual cohort, 69% (146/211) of THAs had a final LLD within ±2 mm of the intraoperatively navigated LLD (ie, ΔLLD ≤2 mm). In the AI cohort, 66% (137/209) of THAs had a final LLD within ±2 mm of the intraoperatively navigated LLD (P = .47). Ninety-nine percent (209/211) of hips in the manual cohort and 98% (205/209) of hips in the AI cohort had a final LLD within ±5 mm of the intraoperatively navigated LLD (P = .45). Conclusions Both AI and human-controlled versions of the same navigation platform were similarly accurate for navigating cup position within the Lewinnek "safe zone" and LLD accuracy.
Collapse
Affiliation(s)
- Justin M. Cardenas
- W.B. Carrell Memorial Clinic, Adult Hip and Knee Reconstruction, Dallas, TX, USA
| | - Dan Gordon
- Baylor University Medical Center, Dallas, TX, USA
| | - Bradford S. Waddell
- W.B. Carrell Memorial Clinic, Adult Hip and Knee Reconstruction, Dallas, TX, USA
| | - Kurt J. Kitziger
- W.B. Carrell Memorial Clinic, Adult Hip and Knee Reconstruction, Dallas, TX, USA
| | - Paul C. Peters
- W.B. Carrell Memorial Clinic, Adult Hip and Knee Reconstruction, Dallas, TX, USA
| | - Brian P. Gladnick
- W.B. Carrell Memorial Clinic, Adult Hip and Knee Reconstruction, Dallas, TX, USA
| |
Collapse
|
4
|
Manzo MA, Lex JR, Rodriguez-Elizalde SR, Perlus R, Cayen B, Chang JS. Fluoroscopy Versus Imageless Optical Navigation in Direct Anterior Approach Total Hip Arthroplasty. J Am Acad Orthop Surg 2024; 32:e284-e292. [PMID: 38166193 DOI: 10.5435/jaaos-d-23-00790] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/01/2023] [Accepted: 11/16/2023] [Indexed: 01/04/2024] Open
Abstract
BACKGROUND Utilization of the direct anterior approach (DAA) for total hip arthroplasty (THA) has risen in popularity. Accurate implant placement is a critical factor that influences patient outcomes. The goal of this study was to compare the accuracy and precision of fluoroscopy with imageless optical navigation in DAA THA. METHODS This was a cohort study of 640 consecutive primary DAA THAs performed with intraoperative fluoroscopy (n = 300 patients) or imageless optical navigation (n = 304 patients). Accuracy was compared by measuring acetabular cup inclination, anteversion, and leg-length discrepancy (LLD). The proportion of implants placed within the Lewinnek safe zone and those placed within a more precise target of 40 ± 5° inclination and 20 ± 5° anteversion was evaluated. RESULTS According to the Lewinnek criteria, there was no difference in the percentage of implants placed within both inclination and anteversion targets (fluoroscopy: 90.3%; navigation: 88.8%, P = 0.519). Using the more precise targets, navigation increased the implants positioned correctly for both inclination and anteversion (fluoroscopy: 50.3%; navigation: 65.6%, P < 0.001). Navigation increased the proportion of implants positioned within the target anteversion zone (fluoroscopy: 71.3%; navigation: 83.8%, P < 0.001) but not inclination (fluoroscopy: 71.9%; navigation: 76.9%, P = 0.147). The mean LLD was higher with the use of fluoroscopy compared with navigation (5.5 mm, standard deviation: 4.1; 4.6 mm, SD: 3.4, P < 0.005). No difference in dislocation rate was observed ( P = 0.643). CONCLUSION Both fluoroscopy and imageless optical navigation demonstrated accurate acetabular implant positioning during DAA THA. Navigation was more precise and associated with improved acetabular anteversion placement and restoration of LLD. Navigation is an accurate alternative to fluoroscopy with decreased radiation exposure.
Collapse
Affiliation(s)
- Marc A Manzo
- From the Temerty Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada (Manzo), the Department of Surgery, Division of Orthopaedic Surgery, Temerty Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada, (Lex, Rodriguez-Elizalde, Perlus, and Cayen, and Chang) and the Division of Orthopaedic Surgery, Humber River Hospital, Toronto, Ontario, Canada (Rodriguez-Elizalde, Perlus, Cayen, and Chang)
| | | | | | | | | | | |
Collapse
|
5
|
Kim HS, Lee HJ, Yoo JJ. Minimal pre-operative leg length discrepancy as a risk factor of post-operative leg length discrepancy after total hip arthroplasty: a retrospective study of patients with non-traumatic osteonecrosis of the femoral head. BMC Musculoskelet Disord 2023; 24:954. [PMID: 38066461 PMCID: PMC10704764 DOI: 10.1186/s12891-023-07086-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/03/2023] [Accepted: 11/30/2023] [Indexed: 12/18/2023] Open
Abstract
BACKGROUND Leg length discrepancy (LLD) is one of the troublesome complications of total hip arthroplasty (THA). Previously, several risk factors have been suggested, but they were subjected to their inherent limitations. By controlling confounding variables, we hypothesized that known risk factors be re-evaluated and novel ones be discovered. This study aimed to analyze the independent risk factors for LLD after primary THA in patients with non-traumatic osteonecrosis of the femoral head (ONFH). METHODS We retrospectively reviewed patients with non-traumatic ONFH who underwent unilateral THA between 2014 and 2021. All patients were operated by one senior surgeon using a single implant. Demographic data, surgical parameters, and radiological findings (pre-operative LLD, Dorr classification, and femoral neck resection) were analyzed to identify the risk factors of ≥ 5 mm post-operative LLD based on radiological measurement and to calculate odds ratios by logistic regression analysis. Post hoc power analysis demonstrated that the number of analyzed patients was sufficient with 80% power. RESULTS One hundred and eighty-six patients were analyzed, including 96 females, with a mean age of 58.8 years at the time of initial THA. The average post-operative LLD was 1.2 ± 2.9 mm in the control group and 9.7 ± 3.2 mm in the LLD group, respectively. The LLD group tended to have minimal pre-operative LLD than the control group (-3.2 ± 5.1 mm vs. -7.9 ± 5.8 mm p = 2.38 × 10- 8). No significant difference was found between the groups in age, gender, body mass index, femoral cortical index, and implant size. CONCLUSION Mild pre-operative LLD is associated with an increased risk of post-operative LLD after primary THA in patients with ONFH. Thus, surgeons should recognize pre-operative LLD to achieve an optimal outcome and must inform patients about the risk of developing LLD.
Collapse
Affiliation(s)
- Hong Seok Kim
- Department of Orthopedic Surgery, Seoul National University Hospital, Seoul, South Korea
- Department of Orthopedic Surgery, College of Medicine, Seoul National University, Seoul, South Korea
| | - Han Jin Lee
- Department of Orthopedic Surgery, Hanil General Hospital, Seoul, South Korea
| | - Jeong Joon Yoo
- Department of Orthopedic Surgery, Seoul National University Hospital, Seoul, South Korea.
- Department of Orthopedic Surgery, College of Medicine, Seoul National University, Seoul, South Korea.
| |
Collapse
|
6
|
Migliorini F, Cuozzo F, Oliva F, Eschweiler J, Hildebrand F, Maffulli N. CT-based navigation for total hip arthroplasty: a meta-analysis. Eur J Med Res 2023; 28:443. [PMID: 37853456 PMCID: PMC10583311 DOI: 10.1186/s40001-023-01437-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2022] [Accepted: 10/07/2023] [Indexed: 10/20/2023] Open
Abstract
INTRODUCTION Computer tomography (CT) based navigation is considered by some authors as an advance in total hip arthroplasty (THA). A meta-analysis was conducted to compare CT based versus conventional THA in terms of surgical duration of the procedure, leg length difference, acetabular cup position, and rate of dislocation. MATERIAL AND METHODS The present study was conducted according to the PRISMA 2020. In December 2022, the following databases were accessed: PubMed, Web of Science, Google Scholar, Embase with no time constrain. All the clinical studies comparing CT based navigation versus the conventional THA were accessed. RESULTS Data from 1801 procedures were collected. The mean age of the patients was 61.6 ± 5.3 years, and the mean BMI was 26.9 ± 2.3 kg/m2. There was between studies comparability at baseline in terms of age, BMI, pain score, Harris hip score, leg length discrepancy (P > 0.1). The navigated group demonstrated lower leg length discrepancy (P = 0.02), and lower degrees of cup anteversion (P = 0.002). Similarity was found in cup inclination (P = 0.98), surgical duration (P = 0.3), and the rate of dislocation (P = 0.6). CONCLUSION CT guided THA may have the potential to increase the accuracy of acetabular positioning and reduce the leg length discrepancy. Current evidence is very limited and heterogeneous, and no recommendations can be inferred. Further investigations are required to definitely clarify the role of CT based THA in current practice.
Collapse
Affiliation(s)
- Filippo Migliorini
- Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany.
- Department of Orthopaedic and Trauma Surgery, Academic Hospital of Bolzano (SABES-ASDAA), Teaching Hospital of the Paracelsus Medical University, 39100, Bolzano, Italy.
| | - Francesco Cuozzo
- Department of Medicine, Surgery and Dentistry, University of Salerno, 84081, Baronissi, SA, Italy
| | - Francesco Oliva
- Department of Human Sciences and Promotion of the Quality of Life, San Raffaele Roma Open University , Rome, Italy
| | - Joerg Eschweiler
- Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany
| | - Frank Hildebrand
- Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany
| | - Nicola Maffulli
- School of Pharmacy and Bioengineering, Keele University Faculty of Medicine, ST4 7QB, Stoke On Trent, England
- Queen Mary University of London, Barts and the London School of Medicine and Dentistry, Centre for Sports and Exercise Medicine, Mile End Hospital, E1 4DG, London, England
- Faculty of Medicine and Psychology , Univeristy of Rome La Sapienza , Rome , Italy
| |
Collapse
|
7
|
Hu TY, Lin DC, Zhou YJ, Zhang ZW, Yuan JJ. Clinical outcomes of robotic-assisted and manual total hip arthroplasty in the same patient: A case report. World J Clin Cases 2023; 11:5519-5524. [PMID: 37637687 PMCID: PMC10450369 DOI: 10.12998/wjcc.v11.i23.5519] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/08/2023] [Revised: 07/19/2023] [Accepted: 07/25/2023] [Indexed: 08/16/2023] Open
Abstract
BACKGROUND Total hip arthroplasty (THA) is an effective treatment for advanced osteonecrosis of the femoral head, which can significantly relieve pain and improve patients' quality of life. Robotic-assisted THA enhances the accuracy and stability of THA surgery and achieves better clinical outcomes than manual THA. CASE SUMMARY We report the clinical outcomes of robotic-assisted THA and manual THA in the same patient with osteonecrosis of the femoral head. A 49-year-old male patient attended our hospital due to more than 3 years of pain in both hip joints. The left hip was treated with robotic-assisted THA. The patient underwent manual THA of the right hip 3 mo after robotic-assisted THA. We obtained postoperative radiograph parameters, Harris hip score and forgotten joint score of the patient 1 year after surgery. CONCLUSION Compared with manual THA, the patient's left hip felt better 1 year after robotic-assisted THA. Robotic-assisted THA resulted in a better Harris hip score and forgotten joint score than manual THA in the same patient with osteonecrosis of the femoral head.
Collapse
Affiliation(s)
- Tian-Ye Hu
- Department of Orthopaedics,Shulan (Hangzhou) Hospital Affiliated to Zhejiang Shuren University Shulan International Medical College, Hangzhou 311000, Zhejiang Province, China
| | - Dao-Chao Lin
- Department of Orthopaedics,Shulan (Hangzhou) Hospital Affiliated to Zhejiang Shuren University Shulan International Medical College, Hangzhou 311000, Zhejiang Province, China
| | - Yi-Jun Zhou
- Department of Orthopaedics,Shulan (Hangzhou) Hospital Affiliated to Zhejiang Shuren University Shulan International Medical College, Hangzhou 311000, Zhejiang Province, China
| | - Zhi-Wu Zhang
- Department of Orthopaedics,Shulan (Hangzhou) Hospital Affiliated to Zhejiang Shuren University Shulan International Medical College, Hangzhou 311000, Zhejiang Province, China
| | - Jia-Jun Yuan
- Department of Orthopaedics,Shulan (Hangzhou) Hospital Affiliated to Zhejiang Shuren University Shulan International Medical College, Hangzhou 311000, Zhejiang Province, China
| |
Collapse
|
8
|
Wu J, Zhuang X, Lin C, He L, Zhang R. Does the use of intraoperative measurement reduce limb length discrepancies after total hip arthroplasty? BMC Musculoskelet Disord 2023; 24:648. [PMID: 37573304 PMCID: PMC10423409 DOI: 10.1186/s12891-023-06774-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/11/2023] [Accepted: 08/02/2023] [Indexed: 08/14/2023] Open
Abstract
PURPOSE Postoperative limb length discrepancy (LLD) is a common complication of total hip arthroplasty, and several methods exist to prevent LLD, but each has its benefits and drawbacks. The study investigates the application of intraoperative lower limb length measurement in preventing postoperative LLD. METHODS This study retrospectively analyzed 70 patients who underwent total hip arthroplasty from October 2018 to July 2022. The length of the lower limb on the operated side was measured intraoperatively using a sterilized paper ruler after the fitting of the trial mould and compared with the healthy side. Then the prosthesis size, depth and neck length were adjusted accordingly. RESULTS The absolute value of postoperative LLD was found to be 6.68 ± 4.48 mm, of which 53 cases (75.7%) were less than or equal to 10 mm, while 30 patients (42.9%) were less than or equal to 5 mm. CONCLUSION The use of intraoperative measurement is effective in reducing LLD after total hip arthroplasty.
Collapse
Affiliation(s)
- Junzhe Wu
- Department of Orthopaedic Surgery, The Second Affiliated Hospital, Fujian Medical University, Quanzhou, Fujian, 362000, China
| | - Xunrong Zhuang
- Department of Orthopaedic Surgery, The Second Affiliated Hospital, Fujian Medical University, Quanzhou, Fujian, 362000, China
| | - Chaohui Lin
- Department of Orthopaedic Surgery, The Second Affiliated Hospital, Fujian Medical University, Quanzhou, Fujian, 362000, China
| | - Lijiang He
- Department of Orthopaedic Surgery, The Second Affiliated Hospital, Fujian Medical University, Quanzhou, Fujian, 362000, China
| | - Rongmou Zhang
- Department of Orthopaedic Surgery, The Second Affiliated Hospital, Fujian Medical University, Quanzhou, Fujian, 362000, China.
| |
Collapse
|
9
|
Ma M, Song P, Zhang S, Kong X, Chai W. Does robot-assisted surgery reduce leg length discrepancy in total hip replacement? Robot-assisted posterior approach versus direct anterior approach and manual posterior approach: a propensity score-matching study. J Orthop Surg Res 2023; 18:445. [PMID: 37344859 PMCID: PMC10286345 DOI: 10.1186/s13018-023-03864-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/20/2022] [Accepted: 05/18/2023] [Indexed: 06/23/2023] Open
Abstract
BACKGROUND Advocates of robot-assisted technique argue that robots could improve leg length restoration in total hip replacement. However, there were few studies to compare the robot-assisted posterior approach (RPA) with conventional posterior approach (PA) THA and direct anterior approach (DAA) THA in LLD. This study aimed to determine whether robot-assisted techniques could significantly reduce LLD compared to manual DAA and manual PA. METHODS We retrospectively reviewed the cohort of consecutive ONFH patients who underwent THA robot-assisted posterior, manual posterior, and manual DAA from January 2018 to December 2020 in one institution. One experienced surgeon performed all procedures. We calculated the propensity score to match similar patients in different groups by multivariate logistic regression analysis for each patient. We included confounders consisting of age at the time of surgery, sex, body mass index (BMI), and preoperative LLD. Postoperative LLD and Harris hip scores (HHS) at two years after surgery of different cohorts were compared. RESULT We analyzed 267 ONFH patients treated with RPA, DAA, or PA (73 RPA patients, 99 DAA patients, and 95 PA patients). After propensity score matching, we generated cohorts of 40 patients in DAA and RPA groups. And we found no significant difference in postoperative LLD between RPA and DAA cohorts (4.10 ± 3.50 mm vs 4.60 ± 4.14 mm, p = 0.577) in this study. The HHS at 2 years postoperatively were 87.04 ± 7.06 vs 85.33 ± 8.34 p = 0.202. After propensity score matching, we generated cohorts of 58 patients in manual PA and RPA groups. And there were significant differences in postoperative LLD between the RPA and PA cohorts. (3.98 ± 3.27 mm vs 5.38 ± 3.68 mm, p = 0.031). The HHS at 2 years postoperatively were 89.38 ± 6.81 vs 85.33 ± 8.81 p = 0.019. After propensity score matching, we generated cohorts of 75 patients in manual DAA and PA groups. And there were significant differences in postoperative LLD between the DAA and PA cohorts. (4.03 ± 3.93 mm vs 5.39 ± 3.83 mm, p = 0.031) The HHS at 2 years postoperatively were 89.71 ± 6.18 vs 86.91 ± 7.20 p = 0.012. CONCLUSION This study found no significant difference in postoperative LLD between RPA and DAA, but we found a significant difference between RPA and manual PA, DAA and manual PA in ONFH patients. We found a significant advantage in leg length restoration in primary total hip arthroplasty with robot-assisted surgery.
Collapse
Affiliation(s)
- Mingyang Ma
- Chinese PLA Medical School, Beijing, China
- Department of Orthopedics, The Fourth Medical Center of Chinese PLA General Hospital, Fuxing Road No. 28, Haidian, Beijing, China
- National Clinical Research Center for Orthopedics Sports Medicine and Rehabilitation, Beijing, China
| | - Ping Song
- Chinese PLA Medical School, Beijing, China
- Department of Orthopedics, The Fourth Medical Center of Chinese PLA General Hospital, Fuxing Road No. 28, Haidian, Beijing, China
- National Clinical Research Center for Orthopedics Sports Medicine and Rehabilitation, Beijing, China
| | - Shuai Zhang
- Chinese PLA Medical School, Beijing, China
- Department of Orthopedics, The Fourth Medical Center of Chinese PLA General Hospital, Fuxing Road No. 28, Haidian, Beijing, China
- National Clinical Research Center for Orthopedics Sports Medicine and Rehabilitation, Beijing, China
| | - Xiangpeng Kong
- Department of Orthopedics, The Fourth Medical Center of Chinese PLA General Hospital, Fuxing Road No. 28, Haidian, Beijing, China
- National Clinical Research Center for Orthopedics Sports Medicine and Rehabilitation, Beijing, China
| | - Wei Chai
- Department of Orthopedics, The Fourth Medical Center of Chinese PLA General Hospital, Fuxing Road No. 28, Haidian, Beijing, China
- National Clinical Research Center for Orthopedics Sports Medicine and Rehabilitation, Beijing, China
| |
Collapse
|
10
|
Huang Z, Zhang Z, Lu X, Liu Y, Zhang H. The influence of prosthetic positioning and proximal femoral morphology on leg length discrepancy and early clinical outcomes of cementless total hip arthroplasty. J Orthop Surg Res 2023; 18:408. [PMID: 37277763 DOI: 10.1186/s13018-023-03847-w] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/03/2023] [Accepted: 05/09/2023] [Indexed: 06/07/2023] Open
Abstract
BACKGROUND Leg length discrepancy (LLD) is a common complication of total hip arthroplasty (THA). However, the relationship between femoral prosthesis filling, proximal femoral morphology, and acetabular prosthesis positioning with postoperative LLD and clinical outcomes is unclear. The aims of this study were to investigate the influence of canal flare index (CFI), canal fill ratio (CFR), center of rotation (COR), and femoral offset (FO) on (1) postoperative LLD; and (2) clinical outcomes in the two stem designs with different coating distribution. METHODS The study cohort included 161 patients who underwent primary cementless THA between January 2021 and March 2022 with either proximal coating or full coating stems. Multivariate logistic regression was used to assess the effect of CFI, CFR, COR, and FO on postoperative LLD, and linear regression to assess their effect on clinical outcomes. RESULTS No statistical difference was found in clinical outcomes or postoperative LLD between the two groups. High CFI (p = 0.014), low ΔVCOR (p = 0.012), and Gender (p = 0.028) were found independent risk factors for LLD one day postoperative. High CFI was also an independent risk factor for postoperative subjectively perceived LLD (p = 0.013). CFR at the level of 2 cm below the LT (p = 0.017) was an independent risk factor for Harris Hip Score. CONCLUSIONS Proximal femoral morphology and acetabular prosthesis positioning but not femoral prosthesis filling affected the LLD. High CFI was an independent risk factor for postoperative LLD and subjectively perceived LLD, and low ΔVCOR was also an independent risk factor for postoperative LLD. Women were susceptible to postoperative LLD.
Collapse
Affiliation(s)
- Zhenchao Huang
- Department of Joint Surgery, The Affiliated Hospital of Qingdao University, Qingdao, 266000, Shandong, China
| | - Zian Zhang
- Department of Joint Surgery, The Affiliated Hospital of Qingdao University, Qingdao, 266000, Shandong, China
| | - Xinzhe Lu
- Department of Joint Surgery, The Affiliated Hospital of Qingdao University, Qingdao, 266000, Shandong, China
| | - Yikai Liu
- Department of Joint Surgery, The Affiliated Hospital of Qingdao University, Qingdao, 266000, Shandong, China
| | - Haining Zhang
- Department of Joint Surgery, The Affiliated Hospital of Qingdao University, Qingdao, 266000, Shandong, China.
| |
Collapse
|
11
|
Deckey DG, Verhey JT, Christopher ZK, Gerhart CRB, Clarke HD, Spangehl MJ, Bingham JS. Discordance Abounds in Minimum Clinically Important Differences in THA: A Systematic Review. Clin Orthop Relat Res 2023; 481:702-714. [PMID: 36398323 PMCID: PMC10013655 DOI: 10.1097/corr.0000000000002434] [Citation(s) in RCA: 15] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/23/2022] [Accepted: 09/08/2022] [Indexed: 11/21/2022]
Abstract
BACKGROUND The minimum clinically important difference (MCID) is intended to detect a change in a patient-reported outcome measure (PROM) large enough for a patient to appreciate. Their growing use in orthopaedic research stems from the necessity to identify a metric, other than the p value, to better assess the effect size of an outcome. Yet, given that MCIDs are population-specific and that there are multiple calculation methods, there is concern about inconsistencies. Given the increasing use of MCIDs in total hip arthroplasty (THA) research, a systematic review of calculated MCID values and their respective ranges, as well as an assessment of their applications, is important to guide and encourage their use as a critical measure of effect size in THA outcomes research. QUESTIONS/PURPOSES We systematically reviewed MCID calculations and reporting in current THA research to answer the following: (1) What are the most-reported PROM MCIDs in THA, and what is their range of values? (2) What proportion of studies report anchor-based versus distribution-based MCID values? (3) What are the most common methods by which anchor-based MCID values are derived? (4) What are the most common derivation methods for distribution-based MCID values? (5) How do the reported medians and corresponding ranges compare between calculation methods for each PROM? METHODS The EMBASE, MEDLINE, and PubMed databases were systematically reviewed from inception through March 2022 for THA studies reporting an MCID value for any PROMs. Two independent authors reviewed articles for inclusion. All articles calculating new PROM MCID scores after primary THA were included for data extraction and analysis. MCID values for each PROM, MCID calculation method, number of patients, and study demographics were extracted from each article. In total, 30 articles were included. There were 45 unique PROMs for which 242 MCIDs were reported. These studies had a total of 1,000,874 patients with a median age of 64 years and median BMI of 28.7 kg/m 2 . Women made up 55% of patients in the total study population, and the median follow-up period was 12 months (range 0 to 77 months). The overall risk of bias was assessed as moderate using the modified Methodological Index for Nonrandomized Studies criteria for comparative studies (the mean score for comparative papers in this review was 18 of 24, with higher scores representing better study quality) and noncomparative studies (for these, the mean score was 10 of a possible 16 points, with higher scores representing higher study quality). Calculated values were classified as anchor-based, distribution-based, or not reported. MCID values for each PROM, MCID calculation method, number of patients, and study demographics were extracted from each study. Anchor-based and distribution-based MCIDs were compared for each unique PROM using a Wilcoxon rank sum test, given the non-normal distribution of values. RESULTS The Oxford Hip Score (OHS) and the Hip Injury and Osteoarthritis Score (HOOS) Pain and Quality of Life subscore MCIDs were the most frequently reported, comprising 12% (29 of 242), 8% (20 of 242), and 8% (20 of 242), respectively. The EuroQol VAS (EQ-VAS) was the next-most frequently reported (7% [17 of 242]) followed by the EuroQol 5D (EQ-5D) (7% [16 of 242]). The median anchor-based value for the OHS was 9 (IQR 8 to 11), while the median distribution-based value was 6 (IQR 5 to 6). The median anchor-based MCID values for HOOS Pain and Quality of Life were 33 (IQR 28 to 35) and 25 (14 to 27), respectively; the median distribution-based values were 10 (IQR 9 to 10) and 13 (IQR 10 to 14), respectively. Thirty percent (nine of 30) of studies used an anchor-based method to calculate a new MCID, while 40% (12 of 30) used a distribution-based technique. Thirty percent of studies (nine of 30) calculated MCID values using both methods. For studies reporting an anchor-based calculation method, a question assessing pain relief, satisfaction, or quality of life on a five-point Likert scale was the most commonly used anchor (30% [eight of 27]), followed by a receiver operating characteristic curve estimation (22% [six of 27]). For studies using distribution-based calculations, the most common method was one-half the standard deviation of the difference between preoperative and postoperative PROM scores (46% [12 of 26]). Most reported median MCID values (nine of 14) did not differ by calculation method for each unique PROM (p > 0.05). The OHS, HOOS JR, and HOOS Function, Symptoms, and Activities of Daily Living subscores all varied by calculation method, because each anchor-based value was larger than its respective distribution-based value. CONCLUSION We found that MCIDs do not vary very much by calculation method across most outcome measurement tools. Additionally, there are consistencies in MCID calculation methods, because most authors used an anchor question with a Likert scale for the anchor-based approach or used one-half the standard deviation of preoperative and postoperative PROM score differences for the distribution-based approach. For some of the most frequently reported MCIDs, however, anchor-based values tend to be larger than distribution-based values for their respective PROMs. CLINICAL RELEVANCE We recommend using a 9-point increase as the MCID for the OHS, consistent with the median reported anchor-based value derived from several high-quality studies with large patient groups that used anchor-based approaches for MCID calculations, which we believe are most appropriate for most applications in clinical research. Likewise, we recommend using the anchor-based 33-point and 25-point MCIDs for the HOOS Pain and Quality of Life subscores, respectively. We encourage using anchor-based MCID values of WOMAC Pain, Function, and Stiffness subscores, which were 29, 26, and 30, respectively.
Collapse
Affiliation(s)
- David G. Deckey
- Department of Orthopaedic Surgery, Mayo Clinic Arizona, Phoenix, AZ, USA
| | - Jens T. Verhey
- Department of Orthopaedic Surgery, Mayo Clinic Arizona, Phoenix, AZ, USA
| | | | | | - Henry D. Clarke
- Department of Orthopaedic Surgery, Mayo Clinic Arizona, Phoenix, AZ, USA
| | - Mark J. Spangehl
- Department of Orthopaedic Surgery, Mayo Clinic Arizona, Phoenix, AZ, USA
| | - Joshua S. Bingham
- Department of Orthopaedic Surgery, Mayo Clinic Arizona, Phoenix, AZ, USA
| |
Collapse
|
12
|
Tang A, Singh V, Sharan M, Roof MA, Mercuri JJ, Meftah M, Schwarzkopf R. The accuracy of component positioning during revision total hip arthroplasty using 3D optical computer-assisted navigation. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY & TRAUMATOLOGY : ORTHOPEDIE TRAUMATOLOGIE 2022:10.1007/s00590-022-03383-z. [PMID: 36074304 DOI: 10.1007/s00590-022-03383-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/07/2022] [Accepted: 08/28/2022] [Indexed: 06/15/2023]
Abstract
INTRODUCTION Despite the excellent outcomes associated with primary total hip arthroplasty (THA), implant failure and revision continue to burden the healthcare system. The use of computer-assisted navigation (CAN) offers the potential for more accurate placement of hip components during surgery. While intraoperative CAN systems have been shown to improve outcomes in primary THA, their use in the context of revision total hip arthroplasty (rTHA) has not been elucidated. We sought to investigate the validity of using CAN during rTHA. METHODS A retrospective analysis was performed at an academic medical institution identifying all patients who underwent rTHA using CAN from 2016-2019. Patients were 1:1 matched with patients undergoing rTHA without CAN (control) based on demographic data. Cup anteversion, inclination, change in leg length discrepancy (ΔLLD) and change in femoral offset between pre- and post-operative plain weight-bearing radiographic images were measured and compared between both groups. A safety target zone of 15-25° for anteversion and 30-50° for inclination was used as a reference for precision analysis of cup position. RESULTS Eighty-four patients were included: 42 CAN cases and 42 control cases. CAN cases displayed a lower ΔLLD (5.74 ± 7.0 mm vs 9.13 ± 7.9 mm, p = 0.04) and greater anteversion (23.4 ± 8.53° vs 19.76 ± 8.36°, p = 0.0468). There was no statistical difference between the proportion of CAN or control cases that fell within the target safe zone (40% vs 20.9%, p = 0.06). Femoral offset was similar in CAN and control cases (7.63 ± 5.84 mm vs 7.14 ± 4.8 mm, p = 0.68). CONCLUSION Our findings suggest that the use of CAN may improve accuracy in cup placement compared to conventional methodology, but our numbers are underpowered to show a statistical difference. However, with a ΔLLD of ~ 3.4 mm, CAN may be useful in facilitating the successful restoration of pre-operative leg length following rTHA. Therefore, CAN may be a helpful tool for orthopedic surgeons to assist in cup placement and LLD during complex revision cases.
Collapse
Affiliation(s)
- Alex Tang
- Department of Orthopedic Surgery, NYU Langone Orthopedic Health, 301 East 17th Street, New York, NY, 10003, USA
- Department of Orthopaedic Surgery, Geisinger Health, Scranton, PA, USA
| | - Vivek Singh
- Department of Orthopedic Surgery, NYU Langone Orthopedic Health, 301 East 17th Street, New York, NY, 10003, USA
- Levitetz Department of Orthopaedic Surgery, Cleveland Clinic Florida, Weston, FL, USA
| | - Mohamad Sharan
- Department of Orthopedic Surgery, NYU Langone Orthopedic Health, 301 East 17th Street, New York, NY, 10003, USA
| | - Mackenzie A Roof
- Department of Orthopedic Surgery, NYU Langone Orthopedic Health, 301 East 17th Street, New York, NY, 10003, USA
| | - John J Mercuri
- Department of Orthopaedic Surgery, Geisinger Health, Scranton, PA, USA
| | - Morteza Meftah
- Department of Orthopedic Surgery, NYU Langone Orthopedic Health, 301 East 17th Street, New York, NY, 10003, USA
| | - Ran Schwarzkopf
- Department of Orthopedic Surgery, NYU Langone Orthopedic Health, 301 East 17th Street, New York, NY, 10003, USA.
| |
Collapse
|
13
|
Guo DH, Li XM, Ma SQ, Zhao YC, Qi C, Xue Y. Total Hip Arthroplasty with Robotic Arm Assistance for Precise Cup Positioning: A Case-Control Study. Orthop Surg 2022; 14:1498-1505. [PMID: 35701994 PMCID: PMC9251322 DOI: 10.1111/os.13334] [Citation(s) in RCA: 22] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/21/2021] [Revised: 05/12/2022] [Accepted: 05/16/2022] [Indexed: 11/30/2022] Open
Abstract
OBJECTIVE To determine whether more precise cup positioning can be achieved with robot-assisted total hip arthroplasty (THA) as compared to conventional THA. METHODS In this study, between July 2019 and May 2021, 93 patients aged 23-75 years with osteonecrosis of the femoral head (ONFH) and adult developmental dysplasia of hip who underwent first hip surgery were included in the study. They were randomly assigned to either the robotic-assisted THA group (n = 45) or the conventional THA group (n = 48). After the operation, all patients were given routine rapid rehabilitation guidance. The duration of operation was recorded to estimate the learning curve through cumulative summation analysis. We compared the demographics, duration of operation, cup positioning, leg length discrepancy, hip offset, and Harris Hip Score between robot-assisted THA and manual THA. Precision in the positioning of the acetabular prosthesis using the MAKO system was also compared between the two groups. RESULTS The mean duration of operation for the robot-assisted THA group was 91.37 ± 17.34 min (range: 63 to 135 min), which was significantly higher than that for the conventional THA group. When the number of procedures was increased to 13, the duration of operation in the robot-assisted group decreased significantly and gradually became stable. In terms of duration of operation, robot-assisted THA was associated with a learning curve of 13 cases. The mean amount of bleeding in the robot-assisted THA group was not significantly different from that in conventional THA group (328 ± 210 ml vs 315 ± 205 ml) (p = 0.741). There was no significant difference in the proportion of prostheses located within Lewinnek's safe zone between robot-assisted THA group and conventional THA group (69.81% vs 64.41%). The leg length discrepancy (LLD) was significantly smaller in the robot-assisted THA group than in the conventional THA group (p < 0.001), but both were within acceptable limits (10 mm). The inclination and anteversion angles of the acetabular prosthesis planned before operations were correlated with the actual measurement (r = 0.857 p < 0.001, r = 0.830, p < 0.001). After surgery, none of the patients experienced hip dislocation, aseptic loosening, or periprosthetic infection during the 3 months of follow-up. CONCLUSION The proportion of acetabular prostheses in the Lewinnek's safety zone was higher and the extent of LLD was significantly lower in the robot-assisted THA group, as compared to the same metrics in the conventional THA group. The MAKO robot improved the accuracy of implant placement in THA.
Collapse
Affiliation(s)
- Dong-Hui Guo
- Department of Orthopaedic Surgery, Tianjin Medical University General Hospital, Tianjin, China.,Department of Orthopaedic Surgery, Cangzhou Hospital of Integrated Traditional Chinese and Western Medicine of Hebei Province, Cangzhou, China
| | - Xiao-Ming Li
- Department of Orthopaedic Surgery, Cangzhou Hospital of Integrated Traditional Chinese and Western Medicine of Hebei Province, Cangzhou, China
| | - Shi-Qiang Ma
- Department of Orthopaedic Surgery, Cangzhou Hospital of Integrated Traditional Chinese and Western Medicine of Hebei Province, Cangzhou, China
| | - Yun-Chao Zhao
- Department of Orthopaedic Surgery, Cangzhou Hospital of Integrated Traditional Chinese and Western Medicine of Hebei Province, Cangzhou, China
| | - Chao Qi
- Department of Orthopaedic Surgery, Cangzhou Hospital of Integrated Traditional Chinese and Western Medicine of Hebei Province, Cangzhou, China
| | - Yuan Xue
- Department of Orthopaedic Surgery, Tianjin Medical University General Hospital, Tianjin, China
| |
Collapse
|
14
|
Migliorini F, Cuozzo F, Oliva F, Eschweiler J, Hildebrand F, Maffulli N. Imageless navigation for primary total hip arthroplasty: a meta-analysis study. J Orthop Traumatol 2022; 23:21. [PMID: 35426527 PMCID: PMC9012775 DOI: 10.1186/s10195-022-00636-9] [Citation(s) in RCA: 19] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/28/2021] [Accepted: 02/26/2022] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND There has been a growing interest in imageless navigation for primary total hip arthroplasty (THA). Its superiority over standard THA is debated. This meta-analysis compared surgical duration, implant positioning, Harris Hip Score and rate of dislocation of imageless navigation versus conventional THA. METHODS The present study was conducted according to the PRISMA 2020 guidelines. All the clinical trials comparing imageless navigation versus conventional for primary THA were accessed. In January 2022, the following databases were accessed: PubMed, Web of Science, Google Scholar and Embase. No time constraints were used for the search. The outcomes of interest were to compare cup inclination and anteversion, leg length discrepancy, surgical duration, Harris Hip Score and rate of dislocation of imageless navigation versus conventional THA. RESULTS Twenty-one studies (2706 procedures) were retrieved. Fifty-two percent of patients were women. There was between-group comparability at baseline in terms of age, body mass index (BMI), visual analogue scale, Harris Hip Score and leg length discrepancy (P > 0.1). Compared with conventional THA, the navigated group demonstrated slightly lower leg length discrepancy (P = 0.02) but longer duration of the surgical procedure (P < 0.0001). Cup anteversion (P = 0.6) and inclination (P = 0.5), Harris Hip Score (P = 0.1) and rate of dislocation (P = 0.98) were similar between the two interventions. CONCLUSION Imageless navigation may represent a viable option for THA.
Collapse
Affiliation(s)
- Filippo Migliorini
- Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, 52074, Aachen, Germany.
| | - Francesco Cuozzo
- Department of Medicine, Surgery and Dentistry, University of Salerno, 84081, Baronissi, SA, Italy
| | - Francesco Oliva
- Department of Medicine, Surgery and Dentistry, University of Salerno, 84081, Baronissi, SA, Italy
| | - Joerg Eschweiler
- Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, 52074, Aachen, Germany
| | - Frank Hildebrand
- Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, 52074, Aachen, Germany
| | - Nicola Maffulli
- Department of Medicine, Surgery and Dentistry, University of Salerno, 84081, Baronissi, SA, Italy.,School of Pharmacy and Bioengineering, Keele University Faculty of Medicine, Stoke on Trent, ST4 7QB, UK.,Queen Mary University of London, Barts and the London School of Medicine and Dentistry, Centre for Sports and Exercise Medicine, Mile End Hospital, London, E1 4DG, UK
| |
Collapse
|
15
|
Fujita M, Hayashi S, Kamenaga T, Fujishiro T, Matsumoto T, Kuroda R. LIGAMENT PRESERVING TOTAL HIP ARTHROPLASTY PREVENTS DIFFERENT LEG LENGTH AND FEMORAL OFFSET. ACTA ORTOPÉDICA BRASILEIRA 2022; 30:e242758. [PMID: 35864827 PMCID: PMC9270039 DOI: 10.1590/1413-785220223001e242758] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/31/2020] [Accepted: 01/21/2021] [Indexed: 11/21/2022]
Abstract
Objectives: The leg length (LL) and femoral offset (FO) discrepancy following total hip arthroplasty (THA) are important factors for postoperative outcomes and restoring native hip biomechanics is essential for THA. Hip capsular ligament contributes to joint stability; however, there are few studies about the influence of ligament preservation on LLD and FO following THA. Methods: We conducted a retrospective study involving 60 patients who underwent primary THA using a short stem through the anterolateral approach between June 2016 and August 2018. From August 2017, we preserved the vertical band of iliofemoral ligament and the pubofemoral ligament in THA, and the compared pre- and postoperative radiographic LLD and FO difference between the ligament preservation (n = 30) and ligament excision (n = 30) groups. Results: Postoperative LLD was significantly smaller in the ligament preservation than in the ligament excision group. The ratio of excessive LLD and FO difference was lower in the ligament preservation group than the ligament excision one. Conclusion: The preservation of the hip capsular ligament suppressed the increased LLD and FO difference. Level of Evidence II; Prognostic Study - Investigation of the Effect of a Patient Characteristic on the Outcome of a Disease .
Collapse
Affiliation(s)
- Masahiro Fujita
- Centre Takatsuki General Hospital, Japan; Kobe University Graduate School of Medicine, Japan
| | | | | | | | | | | |
Collapse
|
16
|
Tone S, Hasegawa M, Naito Y, Wakabayashi H, Sudo A. Accuracy of image-free navigation in intraoperative leg length change from total hip arthroplasty using evaluations from 2D and 3D measurements. BMC Musculoskelet Disord 2021; 22:1021. [PMID: 34872557 PMCID: PMC8647365 DOI: 10.1186/s12891-021-04906-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/22/2021] [Accepted: 11/24/2021] [Indexed: 12/03/2022] Open
Abstract
Background Leg length discrepancy is one of the most common problems after total hip arthroplasty (THA). The aim of this study was to investigate the accuracy of image-free navigation in intraoperative leg length change (LLC) using evaluations from anteroposterior radiographs (2D measurement) and 3D bone models using CT data (3D measurement). Methods One hundred THAs with cementless cups and stems were performed using an image-free navigation system in our hospital. We evaluated the accuracy of image-free navigation based on LLC from 2D and 3D measurements. Furthermore, we also investigated error in absolute value and correlations between 2D and 3D measurements in LLC. Results The accuracy of image-free navigation based on 2D measurement was 94% within 5 mm and 76% within 3 mm. The accuracy of image-free navigation based on 3D measurement was 92% within 5 mm and 81% within 3 mm. The error in absolute value in LLC between 2D and 3D measurements was 1.7 ± 1.4 mm (range, 0 to 6 mm). A strong correlation was observed between 2D and 3D measurements in the LLC. Conclusions In the present study, good accuracy of image-free navigation in intraoperative LLC was confirmed for both evaluation methods from 2D and 3D measurements. In addition, the error in absolute value in the LLC between 2D and 3D measurements was very small, and we observed a strong correlation between 2D and 3D measurements. Based on these results, evaluation of LLC from radiographs was considered sufficient if radiographs can be taken accurately.
Collapse
Affiliation(s)
- Shine Tone
- Department of Orthopaedic Surgery, Mie University, Graduate School of Medicine, 2-174 Edobashi, Tsu, Mie, 514-8507, Japan
| | - Masahiro Hasegawa
- Department of Orthopaedic Surgery, Mie University, Graduate School of Medicine, 2-174 Edobashi, Tsu, Mie, 514-8507, Japan.
| | - Yohei Naito
- Department of Orthopaedic Surgery, Mie University, Graduate School of Medicine, 2-174 Edobashi, Tsu, Mie, 514-8507, Japan
| | - Hiroki Wakabayashi
- Department of Orthopaedic Surgery, Mie University, Graduate School of Medicine, 2-174 Edobashi, Tsu, Mie, 514-8507, Japan
| | - Akihiro Sudo
- Department of Orthopaedic Surgery, Mie University, Graduate School of Medicine, 2-174 Edobashi, Tsu, Mie, 514-8507, Japan
| |
Collapse
|
17
|
Affiliation(s)
- Babar Kayani
- Department of Trauma and Orthopaedic Surgery, University College London Hospital, London, UK.,Department of Orthopaedic Surgery, The Princess Grace Hospital, London, UK
| | - Dia Giebaly
- University College London Hospitals NHS Foundation Trust, London, UK
| | - Fares S Haddad
- The Bone & Joint Journal , London, UK.,University College London Hospitals, The Princess Grace Hospital, and The NIHR Biomedical Research Centre at UCLH, London, UK
| |
Collapse
|
18
|
Kawamura H, Watanabe Y, Nishino T, Mishima H. Effects of lower limb and pelvic pin positions on leg length and offset measurement errors in experimental total hip arthroplasty. J Orthop Surg Res 2021; 16:193. [PMID: 33726774 PMCID: PMC7962310 DOI: 10.1186/s13018-021-02347-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/16/2021] [Accepted: 03/09/2021] [Indexed: 01/23/2023] Open
Abstract
Background Leg length (LL) and offset (OS) are important factors in total hip arthroplasty (THA). Because most LL and OS callipers used in THA depend on fixed points on the pelvis and the femur, limb position could affect measurement error. This study was conducted on a THA simulator to clarify the effects of lower limb position and iliac pin position on LL and OS errors and to determine the permissible range of limb position for accurate LL and OS measurement. Methods An LL and OS measurement instrument was used. Two pin positions were tested: the iliac tubercle and the top of the iliac crest intersecting with the extension of the femoral axis. First, the limb was moved in one direction (flexion-extension, abduction-adduction, or internal-external rotation), and LL and OS were measured for each pin position. Next, the limb was moved in combinations of the three directions. Then, the permissible range of combined limb position, which resulted in LL and OS measurement error within ±2 mm, was determined for each pin position. Results Only 4° of abduction/adduction caused 5–7 mm error in LL and 2–4 mm error in OS, irrespective of pin position. The effects of flexion–extension and internal–external rotation on LL error were smaller for the top of the iliac crest than for the iliac tubercle, though OS error was similar for both pin positions. For LL, the permissible range of the combined limb position was wider for the top of the iliac crest than for the iliac tubercle. Conclusion To minimize LL and OS measurement errors in THA, adduction–abduction must be maintained. The iliac pin position in the top of the iliac crest is preferred because it provides less LL measurement error and a wider permissible range of combined limb position for accurate LL measurement.
Collapse
Affiliation(s)
- Haruo Kawamura
- Department of Orthopaedic Surgery, Kenhoku Medical Center Takahagi Kyodo Hospital, 1006-9 Kamiteduna Agehochou, Takahagi, Ibaraki, 318-0004, Japan.
| | - Yasuhiko Watanabe
- Department of Orthopaedic Surgery, Ryugasaki Saiseikai Hospital, 1-1 Nakasato, Ryugasaki, Ibaraki, 301-0854, Japan
| | - Tomofumi Nishino
- Department of Orthopaedic Surgery, Institute of Clinical Medicine and University Hospital, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki, 305-8575, Japan
| | - Hajime Mishima
- Department of Orthopaedic Surgery, Institute of Clinical Medicine and University Hospital, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki, 305-8575, Japan
| |
Collapse
|
19
|
Sharan M, Tang A, Schoof L, Gaukhman A, Meftah M, Sculco P, Schwarzkopf R. Obesity does not influence acetabular component accuracy when using a 3D optical computer navigation system. J Clin Orthop Trauma 2020; 14:40-44. [PMID: 33717895 PMCID: PMC7919980 DOI: 10.1016/j.jcot.2020.09.028] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/30/2020] [Revised: 09/14/2020] [Accepted: 09/22/2020] [Indexed: 11/24/2022] Open
Abstract
INTRODUCTION Improper cup positioning and leg length discrepancy (LLD) are two of the most common errors following total hip arthroplasty (THA) and are associated with potentially significant consequences. Obesity is associated with increased risk of mechanical complications, including dislocations, which may be secondary to cup malposition and failure to restore leg length and offset. 3D Optical Camera computerassisted navigation (CAN) system may reduce the risk of component malposition and LLD with real time intraoperative feedback. The aim of this study was to investigate whether the use of CAN influences acetabular component placement (CP) accuracy and leg length restoration in obese (body mass index(BMI)≥35kg/m 2 ) patients undergoing primary THA. METHODS A multi-center retrospective review was conducted identifying consecutive THA cases with BMI > 35kg/m 2 using CAN (Intellijoint Hip, Waterloo, CA) from 2015-2019. These patients were then matched with patients undergoing conventional THA (control) at a 1:1 ratio according to BMI, American Society of Anesthesiologists score, and gender. TraumaCad™ software (Brainlab, Chicago, IL) was used to measure cup anteversion, inclination, and change (Δ) in LLD between pre- and postoperative radiographic images. The safety target zones used as reference for precision analysis of CP were 15°-30° for anteversion and 30°-50° for inclination. RESULTS 176 patients were included: 88 CAN and 88 control cases. CAN cases were found to have a lower ΔLLD than controls (3.53±2.12mm vs. 5.00±4.05mm; p=0.003). Additionally, more CAN cases fell within the target safe zone than controls (83% vs.60%, p=0.00083). CONCLUSION Our findings suggest that the use of a CAN system may be more precise in component placement, and useful in facilitating the successful restoration of preoperative leg length following THA than conventional methodology.
Collapse
Affiliation(s)
- Mohamad Sharan
- Department of Orthopedic Surgery, NYU Langone Health, New York, NY, USA,Corresponding author.
| | - Alex Tang
- Department of Orthopedic Surgery, NYU Langone Health, New York, NY, USA
| | - Lauren Schoof
- Department of Orthopedic Surgery, NYU Langone Health, New York, NY, USA
| | | | - Morteza Meftah
- Department of Orthopedic Surgery, NYU Langone Health, New York, NY, USA
| | - Peter Sculco
- Department of Orthopedic Surgery, Hospital for Special Surgery, New York, NY, USA
| | - Ran Schwarzkopf
- Department of Orthopedic Surgery, NYU Langone Health, New York, NY, USA,Corresponding author. Department of Orthopedic Surgery NYU Langone Health, 301 East 17th Street, New York, NY, 10003, USA.
| |
Collapse
|
20
|
Cozzi Lepri A, Villano M, Innocenti M, Porciatti T, Matassi F, Civinini R. Precision and accuracy of robot-assisted technology with simplified express femoral workflow in measuring leg length and offset in total hip arthroplasty. Int J Med Robot 2020; 16:1-6. [PMID: 32735039 DOI: 10.1002/rcs.2141] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2020] [Revised: 06/24/2020] [Accepted: 07/08/2020] [Indexed: 11/06/2022]
Abstract
BACKGROUND Semi-active robot-assisted total hip arthroplasty (THA) has two options to measure the leg length discrepancy (LLD) and combined offset (CO), the 'enhanced' femoral workflow and the so-called 'express' simplified workflow. The purpose of this study was to determine the precision and accuracy of intraoperative LLD and CO measurement with express workflow robotic THA. METHODS Between February 2018 and December 2019, 30 patients underwent an express workflow robot-assisted primary THA for intraoperative LLD and CO measurements. Postoperative radiographs were used for LLD and CO measurement. In order to examine the accuracy of the robotic system assessment, the absolute difference between the robotic assessments and radiographic evaluations was calculated. RESULTS Intraoperative robotic measurements reported a mean error of 0.2-0.6 mm for each registration, with no significant difference between them (p = 0.311). The average absolute discrepancies between the robotic and radiographic assessments in the LLD and CO measurements were 1.3 ± 1.5 mm (p = 0.17) and 1.1 ± 0.9 mm (p = 0.11), respectively, while the Pearson's correlation coefficients were 0.69 and 0.71. CONCLUSIONS An external marker without a femoral array inserted into a screw positioned in the greater trochanter would be an easier and faster method to measure LLD and CO. Our study showed that the measured values of LLD and CO obtained by intraoperative express workflow robot-assisted THA system were precise and accurate.
Collapse
Affiliation(s)
- Andrea Cozzi Lepri
- Orthopedic Unit, Department of Health Sciences, University of Florence, Firenze, Italy.,C.T.O., Firenze, Italy
| | - Marco Villano
- Orthopedic Unit, Department of Health Sciences, University of Florence, Firenze, Italy.,C.T.O., Firenze, Italy
| | - Matteo Innocenti
- Orthopedic Unit, Department of Health Sciences, University of Florence, Firenze, Italy.,C.T.O., Firenze, Italy
| | - Tommaso Porciatti
- Orthopedic Unit, Department of Health Sciences, University of Florence, Firenze, Italy.,C.T.O., Firenze, Italy
| | - Fabrizio Matassi
- Orthopedic Unit, Department of Health Sciences, University of Florence, Firenze, Italy.,C.T.O., Firenze, Italy
| | - Roberto Civinini
- Orthopedic Unit, Department of Health Sciences, University of Florence, Firenze, Italy.,C.T.O., Firenze, Italy
| |
Collapse
|
21
|
Kishimoto Y, Suda H, Kishi T, Takahashi T. A low-volume surgeon is an independent risk factor for leg length discrepancy after primary total hip arthroplasty: a case-control study. INTERNATIONAL ORTHOPAEDICS 2020; 44:445-451. [PMID: 31673739 DOI: 10.1007/s00264-019-04435-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/01/2019] [Accepted: 10/02/2019] [Indexed: 11/30/2022]
Abstract
PURPOSE Leg length discrepancy (LLD) is one of the bothersome complications that reduce patient satisfaction after total hip arthroplasty (THA). This study aimed to investigate the independent risk factors of LLD after primary THA. METHODS This is a case-control study of 163 THAs for 163 patients at our institution between April 2015 and March 2018. The relevant data about the general characteristics of the patients (age, sex, body mass index, and diagnosis), surgery (surgical approach, type of femoral stem fixation, and surgeon volume), and radiological findings (Dorr classification and pre-operative LLD) were reviewed to identify the risk factors of ≥ 5 mm post-operative LLD according to radiological measurement and to calculate odds ratios (OR) via logistic regression analysis. RESULTS The median (interquartile) absolute value of post-operative LLD was 3.9 (2.3-7.4) mm, and 57 (35.0%) patients had LLD of ≥ 5 mm. After controlling for possible confounders, a low-volume surgeon was considered the only independent risk factor of post-operative LLD (adjusted OR: 8.26; 95% confidence interval: 3.48, 19.60; P < 0.001). Among the 103 patients performed by high-volume surgeons, 82 (79.6%) had LLD of < 5 mm, whereas among the 60 patients performed by low-volume surgeons, only 24 (40.0%) achieved LLD of < 5 mm (P < 0.001). CONCLUSION A low-volume surgeon is associated with an increased risk of a post-operative LLD after primary THA, and the importance of measurements should be recognized to prevent post-operative LLD and achieve optimal outcomes. Moreover, surgeons must inform patients about the risk of developing LLD pre-operatively.
Collapse
Affiliation(s)
- Yuji Kishimoto
- Department of Rheumatology, Tottori Red Cross Hospital, 117 Shotoku-cho, Tottori-shi, Tottori, 680-8517, Japan.
- Department of Orthopedic Surgery, Tottori Red Cross Hospital, Tottori, 680-8517, Japan.
| | - Hiroko Suda
- Department of Orthopedic Surgery, Tottori Red Cross Hospital, Tottori, 680-8517, Japan
| | - Takahiro Kishi
- Department of Orthopedic Surgery, Tottori Red Cross Hospital, Tottori, 680-8517, Japan
| | - Toshiaki Takahashi
- Department of Orthopedic Surgery, Tottori Red Cross Hospital, Tottori, 680-8517, Japan
| |
Collapse
|
22
|
Guo R, Chen JY, Zhang G, Zhou Y, Chen J, Chai W. Calculation method to predict postoperative limb length in patients undergoing THA following developmental dysplasia of hips. BMC Musculoskelet Disord 2019; 20:513. [PMID: 31679510 PMCID: PMC6827358 DOI: 10.1186/s12891-019-2903-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/08/2019] [Accepted: 10/18/2019] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Limb length discrepancy (LLD) is one of the main cause of dissatisfaction after total hip arthroplasty (THA). The teardrop-lesser trochanter method can accurately predict and analyze LLD for healthy people. However, for patients with preoperative LLD, no method for predicting postoperative LLD is currently available, and these patients are highly susceptible to more severe LLD after THA. Accordingly, this study proposed a calculation method to predict postoperative limb length for these patients. METHODS Eighty patients who underwent THA between May 2016 and October 2018 due to unilateral developmental dysplasia of the hip (DDH) were evaluated. Relevant parameters were measured from radiographs of full-length lower limbs, e.g. the distance between the rotation center of the hip and the midpoint of the tibial plafond and the distance between the point which was marked at the same height as the lesser trochanter on the anatomical long axis of the femur and the midpoint of the tibial plafond. Then, a mathematical model was established by simplifying the structure from the hip to the ankle. The relationship between the placement position of the prosthesis and the LLD value was calculated by Law of Sines and Iterative Calculation. RESULTS The preoperatively predicted LLD values and the postoperatively measured LLD values were compared, yielding a mean absolute difference of 3.7 (range, 0.1 to 8.6) mm. The intraclass correlation coefficient (ICC) of the two parameters exhibited strong reliability (ICC = 0.911, 95%CI, 0.795 to 0.955). The Bland-Altman plot also showed good conformity between the two parameters. CONCLUSIONS The proposed calculation method effectively predicted the postoperative LLD using preoperative parameters. Despite the complexity of the method, it can go a long way towards reducing the occurrence of severe postoperative LLD in DDH-THA.
Collapse
Affiliation(s)
- Renwen Guo
- Department of Orthopaedic Surgery, Chinese People's Liberation Army General Hospital, 28 Fuxing Road, Beijing, 100853, People's Republic of China
| | - Jerry Yongqiang Chen
- Department of Orthopaedic Surgery, Singapore General Hospital, Outram Road, Singapore, 169608, Singapore
| | - Guoqiang Zhang
- Department of Orthopaedic Surgery, Chinese People's Liberation Army General Hospital, 28 Fuxing Road, Beijing, 100853, People's Republic of China
| | - Yonggang Zhou
- Department of Orthopaedic Surgery, Chinese People's Liberation Army General Hospital, 28 Fuxing Road, Beijing, 100853, People's Republic of China
| | - Jiying Chen
- Department of Orthopaedic Surgery, Chinese People's Liberation Army General Hospital, 28 Fuxing Road, Beijing, 100853, People's Republic of China
| | - Wei Chai
- Department of Orthopaedic Surgery, Chinese People's Liberation Army General Hospital, 28 Fuxing Road, Beijing, 100853, People's Republic of China.
| |
Collapse
|
23
|
Jia J, Zhao Q, Lu P, Fan G, Chen H, Liu C, Liu J, Chen S, Jin Z. Clinical efficacy of orthopilot navigation system versus conventional manual of total hip arthroplasty: A systematic review and meta-analysis. Medicine (Baltimore) 2019; 98:e15471. [PMID: 31096443 PMCID: PMC6531135 DOI: 10.1097/md.0000000000015471] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/04/2022] Open
Abstract
BACKGROUND To compare the clinical efficacy between Orthopilot navigation system and conventional manual surgery in total hip arthroplasty (THA). METHODS Electronic databases were searched to identify randomized controlled trials (RCTs) investigating Orthopilot navigation system versus conventional manual in patients undergoing THA. Outcome measurements include anteversion angle, inclination angle, preoperative leg length discrepancy, postoperative leg length discrepancy and femoral offset. Statistical software Stata 12.0 was used for data-analysis. RESULTS A total of 5 studies were finally included in this meta-analysis. The results showed that the conventional manual group have a less anteversion angle than that in Orthopilot navigation system group (weighted mean difference (WMD) = 4.67, 95% confidence interval (CI) = 3.53, 5.82, P = .000). And pooled analysis showed that the inclination angle in Orthopilot navigation group was less than that in conventional manual group (WMD = -4.19, 95% CI = -8.00, -0.37, P = .031). There was no significant difference between the preoperative leg length discrepancy and postoperative leg length discrepancy (P > .05). Orthopilot navigation system compared with conventional manual procedure was associated with decreased of femoral offset by 2.76 (WMD = -2.76, 95%CI = -3.90, -1.62, P = .000). CONCLUSION Both Orthopilot navigation system and conventional THA result in significant improvements in patient function with similar overall complication rates and have their own edges in cup position.
Collapse
Affiliation(s)
- Jianguo Jia
- Department of Orthopedics, SuZhou WuJiang Hospital of Integrated Traditional Chinese and Western Medicine
| | - Qun Zhao
- Department of Orthopedics, SuZhou WuJiang Hospital of Integrated Traditional Chinese and Western Medicine
| | - Pei Lu
- Department of Orthopedics, the Affiliated Wuxi No. 2 People's Hospital of Nanjing Medical University
| | - Guiyong Fan
- Department of Orthopaedics, Suzhou Kowloom Hospital, Medical College of Shanghai Jiaotong University
| | - Hao Chen
- Department of Orthopaedics, Suzhou Kowloom Hospital, Medical College of Shanghai Jiaotong University
| | - Chaoqun Liu
- Department of Orthopaedics, Suzhou Kowloom Hospital, Medical College of Shanghai Jiaotong University
| | - Jinlian Liu
- Department of Orthopaedics, Suzhou Kowloom Hospital, Medical College of Shanghai Jiaotong University
| | - Sheng Chen
- Department of Orthopaedics, Jiangsu Shengze Hospital, Nanjing Medical University, Suzhou, Jiangsu, China
| | - Zhengshuai Jin
- Department of Orthopaedics, Jiangsu Shengze Hospital, Nanjing Medical University, Suzhou, Jiangsu, China
| |
Collapse
|
24
|
Mavčič B, Dolinar D, Pompe B, Antolič V. Patient-dependent risk factors for self-perceived leg length discrepancy after total hip arthroplasty. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2019; 29:793-799. [PMID: 30680543 DOI: 10.1007/s00590-019-02389-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/02/2018] [Accepted: 01/21/2019] [Indexed: 12/01/2022]
Abstract
PURPOSE Patients with equal objective leg length discrepancy (LLD) may have different subjective perceptions of this condition. Our aim was to analyze the effects of gender, age, operated side, surgical approach, body height, body mass index (BMI) and LLD measurements on self-perceived LLD after total hip arthroplasty (THA). MATERIALS AND METHODS Observational cohort study with minimum 5-year follow-up included 159 patients with unilateral primary THA at a single institution, who reported subjective feeling of equal or unequal leg lengths after THA. Gender, age, body height, BMI, surgical approach, preoperative and postoperative absolute/relative/pelvic radiographic LLD measurements were included in direct comparison between groups and multivariate analyses with self-perceived LLD as the outcome variable. RESULTS Out of 159 participants, 39% subjectively perceived postoperative LLD, while others reported equal leg lengths. The two groups postoperatively differed in the median relative LLD (10 mm vs. 5 mm; p = 0.01) and WOMAC (230 mm vs. 110 mm; p < 0.01), but not in the pelvic radiographic LLD. After adjustment for gender, age, operated side and surgical approach, postoperative relative LLD (odds ratio 1.38 for each 5 mm increment; 95% CI 1.01-1.74) and combination of BMI < 26 kg/m2 and body height < 1.75 m (odds ratio 2.49; 95% CI 1.14-5.41) were independent risk factors for self-perceived LLD. CONCLUSIONS Clinical relative LLD measurements are better predictors of self-perceived postoperative LLD than pelvic radiographic measurements. Patients with smaller body dimensions will more likely report subjective leg length inequality at a given objective LLD, regardless of gender or age.
Collapse
Affiliation(s)
- Blaž Mavčič
- University Medical Centre Ljubljana and Faculty of Medicine, Zaloška 9, 1000, Ljubljana, Slovenia.
| | - Drago Dolinar
- University Medical Centre Ljubljana and Faculty of Medicine, Zaloška 9, 1000, Ljubljana, Slovenia
| | - Borut Pompe
- University Medical Centre Ljubljana and Faculty of Medicine, Zaloška 9, 1000, Ljubljana, Slovenia
| | - Vane Antolič
- University Medical Centre Ljubljana and Faculty of Medicine, Zaloška 9, 1000, Ljubljana, Slovenia
| |
Collapse
|
25
|
Chen CL, Han PF, Zhang ZL, Sun XJ, Lv Z. Clinical efficacy of OrthoPilot navigation system versus conventional manual total hip arthroplasty: A systematic review and meta-analysis. J Int Med Res 2019; 47:505-514. [PMID: 30616454 PMCID: PMC6381494 DOI: 10.1177/0300060518819378] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
Objective This study was performed to compare the clinical efficacy between the OrthoPilot navigation system and conventional manual surgery in patients undergoing total hip arthroplasty. Methods The Embase, PubMed, CINAHL, and Cochrane databases were searched for clinical trials. The outcome measurements were the anteversion angle, inclination angle, and complications. Review Manager 5.3 statistical software was used for the data analysis. Results Significant differences were found in the femoral offset and overall complication rate between the conventional and navigation groups. Additionally, the conventional group had significantly less anteversion than the navigation group. However, the navigation group had significantly better inclination. The operation time was significantly shorter in the conventional than navigation group. Conclusion Both the OrthoPilot navigation system and conventional total hip arthroplasty result in significant improvements in patient function with similar overall complication rates and have their own advantages in achieving good cup position. The conventional procedure has a shorter operation time than does use of a navigation system.
Collapse
Affiliation(s)
- Cheng-Long Chen
- 1 Department of Orthopaedic Surgery, the Second Clinical Medical College of Shanxi Medical University, TaiYuan, China.,These authors contributed equally to this work
| | - Peng-Fei Han
- 1 Department of Orthopaedic Surgery, the Second Clinical Medical College of Shanxi Medical University, TaiYuan, China.,These authors contributed equally to this work
| | - Zhi-Liang Zhang
- 1 Department of Orthopaedic Surgery, the Second Clinical Medical College of Shanxi Medical University, TaiYuan, China
| | - Xiao-Juan Sun
- 2 Department of Orthopaedics, The Alpert Medical School of Brown University, Providence, RI, USA.,3 Department of Orthopaedics, the Second Hospital of Shanxi Medical University, Shanxi Key Laboratory of Bone and Soft Tissue Injury Repair, TaiYuan, China
| | - Zhi Lv
- 4 Department of Orthopaedics, the Second Hospital of Shanxi Medical University, TaiYuan, China
| |
Collapse
|
26
|
Hambright D, Hellman M, Barrack R. Intra-operative digital imaging: assuring the alignment of components when undertaking total hip arthroplasty. Bone Joint J 2018; 100-B:36-43. [PMID: 29292338 PMCID: PMC6424435 DOI: 10.1302/0301-620x.100b1.bjj-2017-0596.r1] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/11/2017] [Accepted: 06/09/2017] [Indexed: 02/07/2023]
Abstract
Aims The aims of this study were to examine the rate at which the
positioning of the acetabular component, leg length discrepancy
and femoral offset are outside an acceptable range in total hip
arthroplasties (THAs) which either do or do not involve the use
of intra-operative digital imaging. Patients and Methods A retrospective case-control study was undertaken with 50 patients
before and 50 patients after the integration of an intra-operative
digital imaging system in THA. The demographics of the two groups
were comparable for body mass index, age, laterality and the indication
for surgery. The digital imaging group had more men than the group
without. Surgical data and radiographic parameters, including the
inclination and anteversion of the acetabular component, leg length
discrepancy, and the difference in femoral offset compared with
the contralateral hip were collected and compared, as well as the
incidence of altering the position of a component based on the intra-operative
image. Results Digital imaging took a mean of five minutes (2.3 to 14.6) to
perform. Intra-operative changes with the use of digital imaging
were made for 43 patients (86%), most commonly to adjust leg length
and femoral offset. There was a decrease in the incidence of outliers
when using intra-operative imaging compared with not using it in
regard to leg length discrepancy (20% versus 52%,
p = 0.001) and femoral offset inequality (18% versus 44%,
p = 0.004). There was also a difference in the incidence of outliers
in acetabular inclination (0% versus 7%, p = 0.023)
and version (0% versus 4%, p = 0.114) compared
with historical results of a high-volume surgeon at the same centre. Conclusion The use of intra-operative digital imaging in THA improves the
accuracy of the positioning of the components at THA without adding
a substantial amount of time to the operation. Cite this article: Bone Joint J 2018;100B(1
Supple A):36–43.
Collapse
Affiliation(s)
- D Hambright
- Barnes-Jewish Hospital , 660 South Euclid, Campus Box 8233, St. Louis, MO 63110, USA
| | - M Hellman
- Barnes-Jewish Hospital, 660 South Euclid, Campus Box 8233, St. Louis, MO 63110, USA
| | - R Barrack
- Barnes-Jewish Hospital, 660 South Euclid, Campus Box 8233, St. Louis, MO 63110, USA
| |
Collapse
|
27
|
Shah SM, Deep K, Siramanakul C, Mahajan V, Picard F, Allen DJ. Computer Navigation Helps Reduce the Incidence of Noise After Ceramic-on-Ceramic Total Hip Arthroplasty. J Arthroplasty 2017; 32:2783-2787. [PMID: 28511948 DOI: 10.1016/j.arth.2017.04.019] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/30/2016] [Revised: 03/31/2017] [Accepted: 04/10/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Noise after ceramic-on-ceramic (CoC) total hip arthroplasty (THA) is a well-recognized problem. Computer navigation has been shown to achieve desired implant orientation. Our aim was (1) to compare the incidence of noise between navigated and conventional CoC THAs and (2) to determine the factors associated with noise. METHODS All patients undergoing CoC THA between March 2009 and August 2012 were considered for this study. Information regarding hip noise was obtained via telephone or postal interview. A comparable cohort of patients in navigated and conventional groups was used to evaluate the incidence of noise. RESULTS A total of 375 CoC THAs using the same implant (202 navigated and 173 conventional) were evaluated. Patients <65 years of age had significantly greater incidence of noise (22.4% vs 6.1%; P < .001). To ensure similarity, a subgroup of cohort <65 years and a 32-mm head size was used to compare the incidence of noise between the navigated (68 THAs) and conventional (118 THAs) groups. Overall incidence of noise was significantly greater in the conventional group (28%) as compared with the navigated group (10%; P = .005). The relative risk of noise for the conventional vs the navigated group was 2.7 (P = .01), and for squeaking was 1.9 (P = .2). Squeaking THAs had significantly lower cup anteversion (13.4° ± 5.2°) as compared with the silent THAs (17.6° ± 6.9°; P = .01). CONCLUSION Navigated CoC THAs were 2.7× less likely to have noise as compared with the conventional ones. Squeaking THAs had significantly lower cup anteversion as compared with the silent ones. Patients of age <65 years had significantly greater incidence of noise after CoC THA.
Collapse
Affiliation(s)
- Siddharth M Shah
- Department of Orthopaedics, Golden Jubilee National Hospital, Clydebank, UK
| | - Kamal Deep
- Department of Orthopaedics, Golden Jubilee National Hospital, Clydebank, UK
| | | | - Vivek Mahajan
- Department of Orthopaedics, Golden Jubilee National Hospital, Clydebank, UK
| | - Frederic Picard
- Department of Orthopaedics, Golden Jubilee National Hospital, Clydebank, UK
| | - David J Allen
- Department of Orthopaedics, Golden Jubilee National Hospital, Clydebank, UK
| |
Collapse
|