1
|
Li LL, Xu RF, He N, Hu TL, Gao WN, Wang XF, Shi DY, Zhao JR, Meng Y. Research progress on measurement methods and evaluation of the hemodialysis adequacy index Kt/V. Ther Apher Dial 2025; 29:3-11. [PMID: 39387225 DOI: 10.1111/1744-9987.14217] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2024] [Revised: 09/16/2024] [Accepted: 09/27/2024] [Indexed: 10/15/2024]
Abstract
The most common form of replacement therapy for end-stage renal disease (ESRD) is hemodialysis, and the adequacy of hemodialysis is strongly associated with the quality of life and long-term survival of patients. Kt/V is currently one of the most important indicators for evaluating the adequacy of hemodialysis. There are many methods for measuring Kt/V, such as blood collection and measurement, dialysate measurement, bioresistive resistance, WinNonlin software analysis, and artificial intelligence. There are different views on the importance of Kt/V as an indicator of the adequacy of hemodialysis. This article provides a literature review of the various methods of measuring Kt/V and on different perspectives on Kt/V as an evaluation of hemodialysis adequacy.
Collapse
Affiliation(s)
- Le-le Li
- Department of Nephrology, The Affiliated Hospital of Inner Mongolia Medical University, Hohhot, Inner Mongolia, China
| | - Rui-Feng Xu
- Department of Nephrology, The Affiliated Hospital of Inner Mongolia Medical University, Hohhot, Inner Mongolia, China
| | - Ning He
- Department of Hemodialysis, The No. 2 Hospital of Hohhot, Hohhot, China
| | - Ta-la Hu
- Department of Nephrology, The Affiliated Hospital of Inner Mongolia Medical University, Hohhot, Inner Mongolia, China
| | - Wu-Niri Gao
- Department of Nephrology, The Affiliated Hospital of Inner Mongolia Medical University, Hohhot, Inner Mongolia, China
| | - Xi-Feng Wang
- Department of Nephrology, The Affiliated Hospital of Inner Mongolia Medical University, Hohhot, Inner Mongolia, China
| | - Dong-Ying Shi
- Department of Nephrology, The Affiliated Hospital of Inner Mongolia Medical University, Hohhot, Inner Mongolia, China
| | - Jian-Rong Zhao
- Department of Nephrology, The Affiliated Hospital of Inner Mongolia Medical University, Hohhot, Inner Mongolia, China
| | - Yan Meng
- Department of Nephrology, The Affiliated Hospital of Inner Mongolia Medical University, Hohhot, Inner Mongolia, China
| |
Collapse
|
2
|
Li G, Jiang L, Li J, Shen H, Jiang S, Ouyang H, Song K. Development and validation of a nomogram for predicting the 6-months survival rate of patients undergoing incident hemodialysis in China. BMC Nephrol 2022; 23:234. [PMID: 35778681 PMCID: PMC9248113 DOI: 10.1186/s12882-022-02864-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2021] [Accepted: 06/07/2022] [Indexed: 11/12/2022] Open
Abstract
Background The all-cause mortality of patients undergoing hemodialysis (HD) is higher than in the general population. The first 6 months after dialysis are important for new patients. The aim of this study was to develop and validate a nomogram for predicting the 6-month survival rate of HD patients. Methods A prediction model was constructed using a training cohort of 679 HD patients. Multivariate Cox regression analyses were performed to identify predictive factors. The identified factors were used to establish a nomogram. The performance of the nomogram was assessed using the C-index and calibration plots. The nomogram was validated by performing discrimination and calibration tests on an additional cohort of 173 HD patients. Results During a follow-up period of six months, 47 and 16 deaths occurred in the training cohort and validation cohort, respectively, representing a mortality rate of 7.3% and 9.2%, respectively. The nomogram comprised five commonly available predictors: age, temporary dialysis catheter, intradialytic hypotension, use of ACEi or ARB, and use of loop diuretics. The nomogram showed good discrimination in the training cohort [C-index 0.775(0.693–0.857)] and validation cohort [C-index 0.758(0.677–0.836)], as well as good calibration, indicating that the performance of the nomogram was good. The total score point was then divided into two risk classifications: low risk (0–90 points) and high risk (≥ 91 points). Further analysis showed that all-cause mortality was significantly different between the high-risk group and the low-risk group. Conclusions The constructed nomogram accurately predicted the 6-month survival rate of HD patients, and thus it can be used in clinical decision-making.
Collapse
Affiliation(s)
- Guode Li
- Department of Cardiology, Maoming People's Hospital, Maoming, Guangdong, China
| | - Linsen Jiang
- Department of Nephrology, The Second Affiliated Hospital of Soochow University, 1055San-Xiang Road, Suzhou, 215004, Jiangsu Province, China
| | - Jiangpeng Li
- Department of Nephrology, The Second Affiliated Hospital of Soochow University, 1055San-Xiang Road, Suzhou, 215004, Jiangsu Province, China
| | - Huaying Shen
- Department of Nephrology, The Second Affiliated Hospital of Soochow University, 1055San-Xiang Road, Suzhou, 215004, Jiangsu Province, China
| | - Shan Jiang
- Department of Nephrology, The Second Affiliated Hospital of Soochow University, 1055San-Xiang Road, Suzhou, 215004, Jiangsu Province, China.
| | - Han Ouyang
- Department of Nephrology, The Second Affiliated Hospital of Soochow University, 1055San-Xiang Road, Suzhou, 215004, Jiangsu Province, China.
| | - Kai Song
- Department of Nephrology, The Second Affiliated Hospital of Soochow University, 1055San-Xiang Road, Suzhou, 215004, Jiangsu Province, China.
| |
Collapse
|
3
|
Petitclerc T, Ridel C. Routine online assessment of dialysis dose: Ionic dialysance or UV-absorbance monitoring? Semin Dial 2021; 34:116-122. [PMID: 33529406 DOI: 10.1111/sdi.12949] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2020] [Revised: 11/01/2020] [Accepted: 12/17/2020] [Indexed: 11/29/2022]
Abstract
For three-weekly hemodialysis, a single-pool Kt/V target of at least 1.4 together with a minimal dialysis dose Kt at 45 L for men and 40 L for women per each session is currently recommended. Fully automatic online calculation of Kt and Kt/V from conductivity or UV-absorbance measurements in the dialysate is standardly implemented on some hemodialysis monitors and makes it possible to estimate the dialysis dose without the need for blood or dialysate samples. Monitoring the UV-absorbance of the spent dialysate is the most direct method for estimating Kt/V as it does not require an estimate of V. Calculation of ionic dialysance from conductivity measurements is the most direct method for estimating Kt and BSA-scaled dialysis dose. Both ionic dialysance monitoring and UV-absorbance monitoring may help detect a change in urea clearance occurring during the session, but this change must be interpreted differently depending on the monitoring being considered. An abrupt decrease in urea clearance results in a decrease in ionic dialysance but, paradoxically, a sudden increase in estimated urea clearance provided by dialysate UV-absorbance monitoring. Healthcare teams who monitor both ionic dialysance and UV-absorbance in their hemodialysis units must be clearly informed of this difficulty.
Collapse
|
4
|
Optimizing dialysis dose in the context of frailty: an exploratory study. Int Urol Nephrol 2021; 53:1025-1031. [PMID: 33515350 DOI: 10.1007/s11255-020-02757-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2020] [Accepted: 12/15/2020] [Indexed: 11/27/2022]
Abstract
INTRODUCTION Frailty is a multicausal syndrome characterized by a decrease in strength, resistance and physiological function, which makes the individual vulnerable and dependent, and increases his/her mortality. This syndrome is more prevalent among older individuals, and chronic kidney disease patients, particularly those on dialysis. Dialysis dose is currently standardized for hemodialysis (HD) patients regardless of their age and functional status. However, it has been postulated that the dialysis dose required in older patients, especially frail ones, should be lower, since it could increase their degree of frailty. Then, the purpose of this study was to evaluate if there would be a correlation between the dose of Kt/V and the degree of frailty in a population of adult patients on HD. MATERIALS AND METHODS A cross-sectional study with 82 patients on HD in Barranquilla (Colombia) and Lobos (Argentina) was conducted. Socio-demographic and laboratory data, as well as dialysis doses (Kt/V) were recorded and scales of fragility, physical activity, gait and grip strength were applied. Then these data were correlated by a Spearman's correlation and a logistic regression. RESULTS CFS, social isolation, physical activity, gait speed, and prehensile strength tests were outside the reference ranges in the studied group. No significant correlation was found between dialysis dose and all the above mentioned functional tests. However, a significant and inverse correlation between physical activity and CFS was documented (score - 1.41 (CI - 2.1 to - 0.7). CONCLUSION No significant correlation was documented between Kt/V value and different parameters of the frailty status, but this status correlated significantly and inversely with physical activity in this group. Frailty status in hemodialysis patients was significantly higher in older individuals, although young individuals were not exempt from it.
Collapse
|
5
|
Casino FG, Mancini E, Santarsia G, Mostacci SD, D'Elia F, Di Carlo M, Iannuzzella F, Rossi L, Vernaglione L, Grimaldi D, Rapanà R, Basile C. What volume to choose to assess online Kt/V? J Nephrol 2019; 33:137-146. [PMID: 31392658 DOI: 10.1007/s40620-019-00636-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2019] [Accepted: 07/31/2019] [Indexed: 11/24/2022]
Abstract
INTRODUCTION Urea distribution volume (V) can be assessed in different ways, among them the anthropometric Watson Volume (VW). However, many studies have shown that VW does not coincide with V and that the latter can be more accurately estimated with other methods. The present multicentre study was designed to answer the question: what V to choose to assess online Kt/V? MATERIALS AND METHODS Pre- and postdialysis blood urea nitrogen concentrations and the usual input data set for urea kinetic modelling were obtained for a single dialysis session in 201 Caucasian patients treated in 9 Italian dialysis units. Only dialysis machines measuring ionic dialysance (ID) were utilized. ID reflects very accurately the mean effective dialyser urea clearance (Kd). Six different V values were obtained: the first one was VW; the second one was computed from the equation established by the HEMO Study to predict the single pool-adjusted modelled V from VW (VH) (Daugirdas JT et al. KI 64: 1108, 2003); the others were estimated kinetically as: 1. V_ID, in which ID is direct input in the in the double pool variable volume (dpVV) calculation by means of the Solute-solver software; 2. V_Kd, in which the estimated Kd is direct input in the dpVV calculation by means of the Solute-solver software; 3. V_KTV, in which V is calculated by means of the second generation Daugirdas equation; 4. V_SPEEDY, in which ID is direct input in the dpVV calculation by means of the SPEEDY software able to provide results quite similar to those provided by Solute-solver. RESULTS Mean± SD of the main data are reported: measured ID was 190.6 ± 29.6 mL/min, estimated Kd was 211.6 ± 29.0 mL/min. The relationship between paired data was poor (R2 = 0.34) and their difference at the Bland-Altman plot was large (21 ± 27 mL/min). VW was 35.3 ± 6.3 L, VH 29.5 ± 5.5, V_ID 28.99 ± 7.6 L, V_SPEEDY 29.4 ± 7.6 L, V_KTV 29.7 ± 7.0 L. The mean ratio VW/V_ID was 1.22, (i.e. VW overestimated V_ID by about 22%). The mean ratio VH/V_ID was 1.02 (i.e. VH overestimated V_ID by only 2%). The relationship between paired data of V_ID and VW was poor (R2 = 0.48) and their mean difference at the Bland-Altman plot was very large (- 6.39 ± 5.59 L). The relationship between paired data of V_ID and VH was poor (R2 = 47) and their mean difference was small but with a large SD (- 0.59 ± 5.53 L). The relationship between paired data of V_ID and V_SPEEDY was excellent (R2 = 0.993) and their mean difference at the Bland-Altman plot was very small (- 0.54 ± 0.64 L). The relationship between paired data of V_ID and V_KTV was excellent (R2 = 0.985) and their mean difference at the Bland-Altman plot was small (- 0.85 ± 1.06 L). CONCLUSIONS V_ID can be considered the reference method to estimate the modelled V and then the first choice to assess Kt/V. V_SPEEDY is a valuable alternative to V_ID. V_KTV can be utilized in the daily practice, taking also into account its simple way of calculation. VW is not advisable because it leads to underestimation of Kt/V by about 20%.
Collapse
Affiliation(s)
- Francesco Gaetano Casino
- Clinical Research Branch, Division of Nephrology, Miulli General Hospital, Acquaviva delle Fonti, Italy.,Dialysis Centre SM2, Policoro, Italy
| | | | | | | | | | | | | | - Luigi Rossi
- Clinical Research Branch, Division of Nephrology, Miulli General Hospital, Acquaviva delle Fonti, Italy
| | | | | | | | - Carlo Basile
- Clinical Research Branch, Division of Nephrology, Miulli General Hospital, Acquaviva delle Fonti, Italy. .,Associazione Nefrologica Gabriella Sebastio, Via Battisti 192, 74121, Taranto, Martina Franca, Italy.
| |
Collapse
|
6
|
Cheng YL, Tang HL, Tong MKL. Clinical practice guidelines for the provision of renal service in Hong Kong: Haemodialysis. Nephrology (Carlton) 2019; 24 Suppl 1:41-59. [DOI: 10.1111/nep.13498] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Affiliation(s)
- Yuk Lun Cheng
- Department of MedicineAlice Ho Miu Ling Nethersole Hospital Hong Kong
| | - Hon Lok Tang
- Renal Unit, Department of Medicine & GeriatricsPrincess Margaret Hospital Hong Kong
| | - Matthew Kwok Lung Tong
- Renal Unit, Department of Medicine & GeriatricsPrincess Margaret Hospital Hong Kong
- Renal Dialysis Centre, Hong Kong Sanatorium & Hospital Hong Kong
| |
Collapse
|
7
|
Updating the Journal Sections for the Evolution of Research and Clinical Applications in Artificial Organs. Int J Artif Organs 2016; 39:261-4. [DOI: 10.5301/ijao.5000515] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/20/2016] [Indexed: 12/18/2022]
|
8
|
He L, Fu M, Chen X, Liu H, Chen X, Peng X, Liu F, Peng Y. Effect of dialysis dose and membrane flux on hemoglobin cycling in hemodialysis patients. Hemodial Int 2014; 19:263-9. [PMID: 25215434 DOI: 10.1111/hdi.12215] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Many studies found that hemoglobin (Hb) fluctuation was closely related to the prognosis of the maintenance hemodialysis patients. We investigated the association of factors relating dialysis dose and dialyzer membrane with Hb levels. We undertook a randomized clinical trial in 140 patients undergoing thrice-weekly dialysis and assigned patients randomly to a standard or high dose of dialysis; Hb level was measured every month for 12 months. In the standard-dose group, the mean (±SD) urea reduction ratio was 65.1% ± 7.3%, the single-pool Kt/V was 1.26 ± 0.11, and the equilibrated Kt/V was 1.05 ± 0.09; in the high-dose group, the values were 73.5% ± 8.7%, 1.68 ± 0.15, and 1.47 ± 0.11, respectively. The standard deviation (SD) and residual SD (liner regression of Hb) values of Hb were significantly higher in the standard-dose group and low-flux group. The percentage achievement of target Hb in the high-dose dialysis group and high-flux dialyzer group was significantly higher than the standard-dose group and low-flux group, respectively. Patients undergoing hemodialysis thrice weekly appear to have benefit from a higher dialysis dose than that recommended by current KDQQI (Kidney Disease Qutcome Quality Initiative) guidelines or from the use of a high-flux membrane, which is in favor of maintaining stable Hb levels.
Collapse
Affiliation(s)
- Liyu He
- Key Laboratory of Kidney Disease and Blood Purification in Hunan, Nephrology Department, 2nd Xiangya Hospital, Central South University, Changsha, Hunan, China
| | | | | | | | | | | | | | | |
Collapse
|