1
|
Bepu DAN, Scatolin RS, Franco NSJ, Sanchez LP, Souza-Gabriel AE, Corona SAM. Alkasite restorative material for endodontically treated teeth: a randomized controlled pilot study. Restor Dent Endod 2024; 49:e24. [PMID: 39247650 PMCID: PMC11377874 DOI: 10.5395/rde.2024.49.e24] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2024] [Revised: 04/13/2024] [Accepted: 05/26/2024] [Indexed: 09/10/2024] Open
Abstract
Objectives This study aimed to evaluate the clinical performance of an alkasite restorative material in molars that had undergone root canal treatment. Materials and Methods The research was registered in Brazilian Registry of Clinical Trials. The randomized clinical trial involved 33 patients, each with at least 1 mandibular molar requiring restoration after receiving endodontic treatment. Patients were randomly assigned to receive either bulk-fill resin composite (Tetric N Ceram Bulk Fill, Ivoclar Vivadent) or the alkasite restorative material (Cention N, Ivoclar Vivadent). Upon completion of the restorations, 3 calibrated professionals utilized the United States Public Health Service criteria to assess various factors, including retention, secondary caries, marginal adaptation, restoration color, marginal pigmentation, and anatomical form. Evaluations were conducted at intervals of 7 days, 6 months, and 17 months. Additionally, the assessment encompassed the presence of radiolucent lines adjacent to the restoration, material deficiencies or excess, contact points, and caries recurrence. The data underwent analysis using the Friedman and Mann-Whitney tests (α = 0.05). Results After 17 months, the results revealed that the alkasite restorative material exhibited greater wear of anatomical shape compared to the bulk-fill resin composite (p = 0.0189). Furthermore, the alkasite restorative material significantly differed from the natural tooth color in most cases (p = 0.0000). However, no other criteria displayed significant differences between the materials or over time (p > 0.05). Conclusions The alkasite restorative material (Cention N) emerges as a viable option for restoring endodontically treated teeth, displaying clinically acceptable alterations after a 17-month evaluation period. Trial Registration Brazilian Registry of Clinical Trials (ReBEC) Identifier: RBR-97kx5jv.
Collapse
Affiliation(s)
- Davi Ariel Nobuo Bepu
- Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirão Preto, SP, Brazil
| | - Renata Siqueira Scatolin
- Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirão Preto, SP, Brazil
| | - Natalia Saud Junqueira Franco
- Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirão Preto, SP, Brazil
| | - Luiza Pejon Sanchez
- Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirão Preto, SP, Brazil
| | - Aline Evangelista Souza-Gabriel
- Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirão Preto, SP, Brazil
| | - Silmara Aparecida Milori Corona
- Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirão Preto, SP, Brazil
| |
Collapse
|
2
|
Barakat RM, Almohareb RA, Alsayyar A, Almalki F, Alharbi H. Evaluation of Dentinal Microcracks following Diode Laser- and Ultrasonic-Activated Removal of Bioceramic Material during Root Canal Retreatment. SCANNING 2022; 2022:6319743. [PMID: 36570434 PMCID: PMC9705085 DOI: 10.1155/2022/6319743] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/01/2022] [Revised: 10/20/2022] [Accepted: 11/15/2022] [Indexed: 06/17/2023]
Abstract
This study is aimed at evaluating the use of microcomputed tomography (micro-CT) analysis and the dentinal microcrack formation following retreatment of bioceramic sealer employing adjunct laser-activated irrigation and ultrasonic-activated irrigation. Thirty sound human single-canal teeth (n = 30) obturated using the single-cone technique with bioceramic sealer were retreated using nickel-titanium (NiTi) rotary files. The sample was randomly divided into three equal groups: group 1, the control group, was not subjected to further treatment; group 2 underwent ultrasonic activation of irrigants; group 3 underwent active irrigation with a diode laser (980 nm wavelength). Using micro-CT, the teeth were scanned before and after retreatment protocols. Two calibrated experienced observers viewed the cross-sectional images and calculated the number of dentinal defects. The presence of any crack or craze line on the external root surface or internal canal wall was counted. Data were analyzed using Friedman's two-way analysis of variance and Fisher's exact test. Statistical significance was set at p < 0.05. A significant increase occurred in the number of cracks post retreatment protocols, specifically in the coronal and middle canal thirds, compared to pre- and postinstrumentation (p = 0.0001). However, ultrasonic- or laser-activated irrigation did not result in a significant increase in the number of cracks (p = 0.345). NiTi rotary root canal retreatment was associated with a significant increase in dentinal microcracks. However, employing ultrasonic- or laser-activated irrigation as adjunct retreatment techniques did not reveal a significant increase in dentinal microcracks within the roots.
Collapse
Affiliation(s)
- Reem M. Barakat
- Department of Clinical Dental Sciences, College of Dentistry, Princess Nourah Bint Abdulrahman University, P.O. Box 84428, Riyadh 11671, Saudi Arabia
| | - Rahaf A. Almohareb
- Department of Clinical Dental Sciences, College of Dentistry, Princess Nourah Bint Abdulrahman University, P.O. Box 84428, Riyadh 11671, Saudi Arabia
| | - Aljuharh Alsayyar
- Dental Intern, College of Dentistry, Princess Nourah Bint Abdulrahman University, P.O. Box 84428, Riyadh 11671, Saudi Arabia
| | - Fayruz Almalki
- Dental Intern, College of Dentistry, Princess Nourah Bint Abdulrahman University, P.O. Box 84428, Riyadh 11671, Saudi Arabia
| | - Hissah Alharbi
- Dental Intern, College of Dentistry, Princess Nourah Bint Abdulrahman University, P.O. Box 84428, Riyadh 11671, Saudi Arabia
| |
Collapse
|
3
|
Tonelli SQ, de Toubes KS, Brabo Pereira AM, de Oliveira Miranda AC, Fernandes LL, Nunes E, Silveira FF. Dentinal microcracks induced by endodontic procedures: A scientometric and bibliometric analysis. J Conserv Dent 2022; 25:78-87. [PMID: 35722065 PMCID: PMC9200181 DOI: 10.4103/jcd.jcd_469_21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2021] [Revised: 12/18/2021] [Accepted: 12/25/2021] [Indexed: 11/29/2022] Open
Abstract
Background Due to the large number of publications relating the occurrence of dental microcracks to endodontic procedures, this bibliometric study evaluated the scientific pattern and trends in literature and provided an overview of scientific production in this context. Aim To analyze, quantify, and characterize the scientific production and trends of published articles evaluating dentinal microcracks formation after endodontic treatment procedures between 2010 and 2020 using bibliometric indicators. Materials and Methods Published articles were found by the search in the Medline (PubMed) and Scopus database using the combination of the following keywords: Dentinal crack OR Dentinal Microcrack OR Crack formation OR Dentin Defect AND Endodontic treatment OR Root canal preparation OR Canal Preparation OR Root canal treatment OR endodontic procedures. The search was also conducted in the Journal of Endodontics and International Endodontic Journal. After inclusion and exclusion criteria application, data from all studies included were collected. Results Among the 556 results after the search, 45 studies were included and analyzed in this bibliometry. No trend was observed in terms of the increasing number of articles over time. Most of them used an in vitro design, compared the effect of different endodontic techniques/systems for root canal instrumentation on dentinal microcracks formation, and were conducted in Turkey, Brazil, and India. Journal of Endodontics and International Endodontic Journal were the main journals with a higher number of articles published. Interestingly, studies conducted with some funding did not lead to higher citation numbers. Moreover, a relevant proportion of studies did not consider the inclusion of control groups, baseline evaluation, or statistical analysis. Micro-CT was the main technique used to evaluate microcrack presence. Conclusion Microcrack formation after the use of different endodontic techniques/systems has been constantly evaluated in the literature. There is a pattern of methodologies used, which may explain the concentration of these studies in specific journals and countries.
Collapse
Affiliation(s)
- Stéphanie Quadros Tonelli
- Department of Dentistry, Pontifical Catholic University of Minas Gerais, Avenida Dom José Gaspar, 500, Belo Horizonte, MG 30535-901, Brazil
| | - Kênia Soares de Toubes
- Department of Dentistry, Pontifical Catholic University of Minas Gerais, Avenida Dom José Gaspar, 500, Belo Horizonte, MG 30535-901, Brazil
| | - André Maués Brabo Pereira
- Department of Civil and Environmental Engineering, University of Brasília, SG-12 Building, Darcy Ribeiro Campus, DF 70910-900, Brazil
| | - Antônio Carlos de Oliveira Miranda
- Department of Computer Science, Institute of Computing, Fluminense Federal University, Rua Passo da Patria, 156, Niterói, RJ 24220-900, Brazil
| | - Letícia Ladeia Fernandes
- Department of Dentistry, Pontifical Catholic University of Minas Gerais, Avenida Dom José Gaspar, 500, Belo Horizonte, MG 30535-901, Brazil
| | - Eduardo Nunes
- Department of Dentistry, Pontifical Catholic University of Minas Gerais, Avenida Dom José Gaspar, 500, Belo Horizonte, MG 30535-901, Brazil
| | - Frank Ferreira Silveira
- Department of Dentistry, Pontifical Catholic University of Minas Gerais, Avenida Dom José Gaspar, 500, Belo Horizonte, MG 30535-901, Brazil
| |
Collapse
|
4
|
Dentinal Microcracks Induced by Endodontic Procedures: Suggested Design for Experimental Studies Using Micro-Computed Tomography and Strain Gauges. J Endod 2021; 47:1157-1165. [PMID: 33901544 DOI: 10.1016/j.joen.2021.04.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2021] [Revised: 03/17/2021] [Accepted: 04/14/2021] [Indexed: 10/21/2022]
Abstract
INTRODUCTION The present study aimed to describe an in vitro study model to investigate root surface strain (RSS) and its correlation with the initiation/propagation of microcracks during different endodontic procedures. METHODS Four lower human incisors extracted microcrack free were selected by micro-computed tomographic imaging. Two strain gauges were bonded to the root surface of each incisor. Then, the teeth were prepared to reproduce the periodontal ligament artificially. The gauges were attached to a data acquisition system. The RSS was recorded during the entire endodontic procedure, which consisted of accessing the endodontic cavity, cleaning, shaping preparation with an Mtwo rotary system (VDW, Munich, Germany), and filling with a standardized technique. Each incisor was submitted to a different retreatment protocol and supplementary cleaning method as follows: (1) Reciproc (RC, VDW) + Flatsonic (FS; Helse, Santa Rosa de Viterbo, Brazil), (2) RC + XP-endo Finisher (XPF; FKG Dentaire, La Chaux-de-Fonds, Switzerland), (3) Mtwo retreatment (MR) + FS, and (4) MR + XPF. Finally, the teeth were rescanned to establish the postoperative microcrack formation by 2 well-trained and blinded examiners. RESULTS The maximum and minimum RSS values were -120 and 510 microstrains, respectively, for all of the files. RC showed the highest RSS values during endodontic retreatment compared with MR. FS demonstrated a higher variation between the minimum and maximum RSS than XPF. No microcracks were observed in the specimens. CONCLUSIONS This preliminary study proposed an experimental model that would combine 2 methods to evaluate the effects of endodontic systems on dentin. Although strain gauges would provide data on the stresses created, the pre- and postoperative evaluation of micro-computed tomographic images would enable microcrack formation to be determined.
Collapse
|
5
|
Almeida A, Romeiro K, Cassimiro M, Gominho L, Dantas E, Silva S, Albuquerque D. Micro-CT analysis of dentinal microcracks on root canals filled with a bioceramic sealer and retreated with reciprocating instruments. Sci Rep 2020; 10:15264. [PMID: 32943675 PMCID: PMC7498450 DOI: 10.1038/s41598-020-71989-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2020] [Accepted: 07/28/2020] [Indexed: 12/18/2022] Open
Abstract
This study aimed to analyze the potential occurrence of dentinal defects after the removal of a root canal filling with two different sealers using Reciproc (RC) or Reciproc Blue (RB). The mesial roots of 60 mandibular molars with a Vertucci type IV configuration were selected. The samples were initially instrumented with Reciproc (R25) and then divided into the following four experimental groups according to the endodontic sealer and retreatment instrument (n = 15): BC Sealer/Reciproc (BCRC); BC Sealer/Reciproc Blue (BCRB); AH Plus/Reciproc (AHRC); and AH Plus/Reciproc Blue (AHRB). Then, the samples were scanned under micro-CT after obturation and removal of the filling material. Two analyses were conducted. First, an evaluation was performed on all the axial images, and another analysis evaluated each millimeter of the 10 mm from the apex. Dentinal defects were observed in all the samples. All of the identified defects in the images after filling material removal were present in the corresponding images after obturation. The use of AH Plus and EndoSequence BC Sealer, and filling material removal using RC and RB instruments did not induce dentinal defects.
Collapse
Affiliation(s)
- Andressa Almeida
- Department of Operative Dentistry and Endodontics, Dental College of Pernambuco, University of Pernambuco (UPE), Avenida General Newton Cavalcanti, 1650, Camaragibe, PE, 54753-020, Brazil.
| | - Kaline Romeiro
- Department of Operative Dentistry and Endodontics, Dental College of Pernambuco, University of Pernambuco (UPE), Avenida General Newton Cavalcanti, 1650, Camaragibe, PE, 54753-020, Brazil
| | - Marcely Cassimiro
- Department of Operative Dentistry and Endodontics, Dental College of Pernambuco, University of Pernambuco (UPE), Avenida General Newton Cavalcanti, 1650, Camaragibe, PE, 54753-020, Brazil
| | - Luciana Gominho
- Department of Clinic and Social Dentistry, Federal University of Paraiba (UFPB), João Pessoa, PB, Brazil
| | - Eugênia Dantas
- Department of Clinic and Social Dentistry, Federal University of Paraiba (UFPB), João Pessoa, PB, Brazil
| | - Silmara Silva
- Department of Operative Dentistry and Endodontics, Dental College of Pernambuco, University of Pernambuco (UPE), Avenida General Newton Cavalcanti, 1650, Camaragibe, PE, 54753-020, Brazil
| | - Diana Albuquerque
- Department of Operative Dentistry and Endodontics, Dental College of Pernambuco, University of Pernambuco (UPE), Avenida General Newton Cavalcanti, 1650, Camaragibe, PE, 54753-020, Brazil
| |
Collapse
|