1
|
Çakmak G, Asadolahi NW, Schimmel M, Molinero-Mourelle P, Akay C, Donmez MB, Yilmaz B. Effect of coffee thermal cycling on the surface properties and stainability of additively manufactured denture base resins in different layer thicknesses. J Prosthodont 2023. [PMID: 37968565 DOI: 10.1111/jopr.13803] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Revised: 10/25/2023] [Accepted: 11/09/2023] [Indexed: 11/17/2023] Open
Abstract
PURPOSE To compare the effect of coffee thermal cycling on surface roughness (Ra), Vickers microhardness (MH), and stainability of denture base resins additively manufactured in different layer thicknesses with those of subtractively manufactured denture base materials. MATERIALS AND METHODS Eighty disk-shaped specimens (Ø10×2 mm) were fabricated from two subtractively (Merz M-PM [SM-M] and G-CAM [SM-G]) and three additively (NextDent 3D+ [50 µm, AM-N-50; 100 µm, AM-N-100], FREEPRINT Denture [50 µm, AM-F-50; 100 µm, AM-F-100], and Denturetec [50 µm, AM-S-50; 100 µm, AM-S-100]) manufactured denture base materials (n = 10). Ra measurements were performed before and after polishing by using a non-contact optical profilometer, while MH values and color coordinates were measured after polishing. Specimens were then subjected to 5000 cycles of coffee thermal cycling, all measurements were repeated, and color differences (ΔE00) were calculated. A linear mixed effect model was used to analyze Ra and MH data, while one-way analysis of variance was used to analyze ΔE00 data (α = 0.05). Ra values were further evaluated according to a clinically acceptable threshold of 0.2 µm, while ΔE00 values were evaluated according to perceptibility (1.72 units) and acceptability (4.08 units) thresholds. The interaction between the material type and the time interval affected both Ra and MH (p ≤ 0.001). Tested materials had their highest Ra before polishing (p ≤ 0.029). Before polishing, AM-F-100 had the highest, and SM-M and SM-G had the lowest Ra (p < 0.001). After polishing and after coffee thermal cycling, SM-G mostly had lower Ra than those of other materials (p ≤ 0.036). SM-G mostly had higher MH than that of other materials before and after coffee thermal cycling (p ≤ 0.025). Coffee thermal cycling reduced the MH of SM-M and increased that of AM-S-100 (p ≤ 0.024). AM-N-100 had higher ΔE00 than AM-F, AM-S-100, and SM-G (p ≤ 0.009), while AM-F and SM-G had lower ΔE00 than AM-S-50 and AM-N-50 (p ≤ 0.024). CONCLUSIONS Polishing reduced the surface roughness of all materials, whereas the effect of coffee thermal cycling was nonsignificant. Most of the tested materials had acceptable surface roughness after polishing and after coffee thermal cycling according to the reported threshold. Layer thickness only affected the microhardness of tested additively manufactured resins, which was material-dependent. Subtractively manufactured specimens mostly had high microhardness and that of nonreinforced subtractively manufactured resin decreased after coffee thermal cycling. When reported color thresholds are considered, all materials had acceptable color stability.
Collapse
Affiliation(s)
- Gülce Çakmak
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Nura Watson Asadolahi
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Martin Schimmel
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Pedro Molinero-Mourelle
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Canan Akay
- Department of Prosthodontics, Faculty of Dentistry, Osmangazi University, Eskisehir, Turkey
- Translational Medicine Research and Clinical Center, Osmangazi University, Eskisehir, Turkey
| | - Mustafa Borga Donmez
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Department of Prosthodontics, Faculty of Dentistry, Istinye University, İstanbul, Turkey
| | - Burak Yilmaz
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland
- Division of Restorative and Prosthetic Dentistry, The Ohio State University, Ohio, USA
| |
Collapse
|
2
|
AYAZ EAYDOĞAN, ALADAĞ SÜSTÜN. Effect of cigarette smoke and denture cleansers on the surface properties and color stability of CAD-CAM and conventional denture base resins. Dent Mater J 2023; 42:167-176. [PMID: 36476683 DOI: 10.4012/dmj.2022-117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
This study aimed to evaluate the hardness, roughness, and color stability of heat- and microwave-polymerized polymethyl methacrylate (PMMA), polyamide, and CAD-CAM PMMA resins when exposed to cigarette smoke (CS) and immersed in a denture cleanser (DC). Specimens of each resins were divided into four subgroups (n=10). The DC and CS+DC specimens were immersed in a DC; the CS and CS+DC specimens were exposed to CS; and the control (C) specimens were kept in distilled water. Hardness, roughness, and color measurements were performed. DC and CS significantly affected the roughness and color of all resins (p<0.05). However, these did not affect the hardness of the CAD-CAM PMMA resin (p>0.05). The CAD-CAM PMMA resin presented the lowest roughness, highest hardness, and lowest ΔE00 values. While the roughness of all resins exposed to CS when immersed in DC decreased, the ΔE00 values of the conventional PMMAs also decreased. Although this decreases were not significant, it may be advisable to use DC for smokers to decrease discoloration and roughness especially for conventional PMMAs resins.
Collapse
Affiliation(s)
- Elif AYDOĞAN AYAZ
- Department of Prosthodontics, Faculty of Dentistry, Karadeniz Technical University
| | - Seda ÜSTÜN ALADAĞ
- Department of Prosthodontics, Faculty of Dentistry, Bursa Uludağ University
| |
Collapse
|
3
|
Analysis of the physical, mechanical and morphological properties of polyethylene terephthalate polymer in the manufacture of dentistry prosthetic components. Polym Bull (Berl) 2022. [DOI: 10.1007/s00289-022-04621-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
4
|
Chuchulska B, Hristov I, Dochev B, Raychev R. Changes in the Surface Texture of Thermoplastic (Monomer-Free) Dental Materials Due to Some Minor Alterations in the Laboratory Protocol-Preliminary Study. MATERIALS (BASEL, SWITZERLAND) 2022; 15:6633. [PMID: 36233975 PMCID: PMC9570521 DOI: 10.3390/ma15196633] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/12/2022] [Revised: 09/16/2022] [Accepted: 09/20/2022] [Indexed: 06/16/2023]
Abstract
Contemporary thermoplastic monomer-free prosthetic materials are widely used nowadays, and there are a great variety available on the market. These materials are of interest in terms of the improvement of the quality features of the removable dentures. The aim of this study is to establish how minimal changes in the laboratory protocol of polyamide prosthetic base materials influence the surface texture. Two polyamide materials intended for the fabrication of removable dentures bases were used-Perflex Biosens (BS) and VertexTM ThermoSens (TS). A total number of 20 coin-shaped samples were prepared. They were injected under two different modes-regular, as provided by the manufacturer, and modified, proposed by the authors of this study. Scanning electronic microscopy (SEM) under four magnifications-×1000, ×3000, ×5000, and ×10,000-was conducted. With minimal alterations to the melting temperature (5 °C) and the pressure (0.5 Bar), in Biosens, no changes in terms of surface improvement were found, whereas in ThermoSens, the surface roughness of the material significantly changed in terms of roughness reduction. By modifying the technological mode during injection molding, a smoother surface was achieved in one of the studied materials.
Collapse
Affiliation(s)
- Bozhana Chuchulska
- Department of Prosthetic Dental Medicine, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria
| | - Ilian Hristov
- Department of Prosthetic Dental Medicine, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria
| | - Boyan Dochev
- Department of Mechanics, Faculty of Mechanical Engineering, Technical University of Sofia, Branch Plovdiv, 4000 Plovdiv, Bulgaria
| | - Raycho Raychev
- Department of Mechanics, Faculty of Mechanical Engineering, Technical University of Sofia, Branch Plovdiv, 4000 Plovdiv, Bulgaria
| |
Collapse
|
5
|
Çakmak G, Molinero-Mourelle P, De Paula MS, Akay C, Cuellar AR, Donmez MB, Yilmaz B. Surface Roughness and Color Stability of 3D-Printed Denture Base Materials after Simulated Brushing and Thermocycling. MATERIALS (BASEL, SWITZERLAND) 2022; 15:ma15186441. [PMID: 36143757 PMCID: PMC9503686 DOI: 10.3390/ma15186441] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Revised: 09/13/2022] [Accepted: 09/14/2022] [Indexed: 05/31/2023]
Abstract
Three-dimensional (3D) printing is increasingly used to fabricate denture base materials. However, information on the effect of simulated brushing and thermocycling on the surface roughness and color stability of 3D-printed denture base materials is lacking. The aim of this study was to evaluate the effect of brushing and thermocycling on the surface roughness and color stability of 3D-printed denture base materials and to compare with those of milled and heat-polymerized denture base resins. Disk-shaped specimens (Ø 10 mm × 2 mm) were prepared from 4 different denture base resins (NextDent Denture 3D+ (ND); Denturetec (SC); Polident d.o.o (PD); Promolux (CNV)) (n = 10). Surface roughness (Ra) values were measured before and after polishing with a profilometer. Initial color coordinates were measured by using a spectrophotometer after polishing. Specimens were then consecutively subjected to simulated brushing (10,000 cycles), thermocycling (10,000 cycles), and brushing (10,000 cycles) again. Ra and color coordinates were measured after each interval. Color differences (ΔE00) between each interval were calculated and these values were further evaluated considering previously reported perceptibility (1.72 units) and acceptability (4.08 units) thresholds. Data were analyzed with Friedman, Kruskal-Wallis, and Mann-Whitney U tests (α = 0.05). Ra (p ≥ 0.051) and ΔE00 (p ≥ 0.061) values among different time intervals within each material were similar. Within each time interval, significant differences in Ra (p ≤ 0.002) and ΔE00 values (p ≤ 0.001) were observed among materials. Polishing, brushing, and thermocycling resulted in acceptable surface roughness for all materials that were either similar to or below 0.2 µm. Color of ND printed resin was affected by brushing and thermocycling. All materials had acceptable color stability when reported thresholds are considered.
Collapse
Affiliation(s)
- Gülce Çakmak
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, 3012 Bern, Switzerland
| | - Pedro Molinero-Mourelle
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, 3012 Bern, Switzerland
| | - Marcella Silva De Paula
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, 3012 Bern, Switzerland
- Department of Prevention and Oral Rehabilitation, Universidade Federal de Goiás, Goiânia 74690-900, Goiás, Brazil
| | - Canan Akay
- Department of Prosthodontics, Faculty of Dentistry, Eskişehir Osmangazi University, Eskisehir 26040, Turkey
- Translational Medicine Research and Clinical Center, Eskişehir Osmangazi University, Eskisehir 26040, Turkey
| | | | - Mustafa Borga Donmez
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, 3012 Bern, Switzerland
- Department of Prosthodontics, Faculty of Dentistry, Istinye University, Istanbul 34010, Turkey
| | - Burak Yilmaz
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, 3012 Bern, Switzerland
- Department of Restorative, Preventive, and Pediatric Dentistry, School of Dental Medicine, University of Bern, 3012 Bern, Switzerland
- Division of Restorative and Prosthetic Dentistry, The Ohio State University, Columbus, OH 43210, USA
| |
Collapse
|
6
|
Fouda SM, Gad MM, Ellakany P, Al Ghamdi MA, Khan SQ, Akhtar S, Al Eraky DM, Al-Harbi FA. Effect of Low Nanodiamond Concentrations and Polymerization Techniques on Physical Properties and Antifungal Activities of Denture Base Resin. Polymers (Basel) 2021; 13:polym13244331. [PMID: 34960883 PMCID: PMC8708888 DOI: 10.3390/polym13244331] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2021] [Revised: 11/29/2021] [Accepted: 12/06/2021] [Indexed: 12/31/2022] Open
Abstract
Background: Denture base resin has some drawbacks. This study investigated the impact of nanodiamonds (ND) and autoclave polymerization on the surface characteristics, translucency, and Candida albicans adherence in polymethyl methacrylate (PMMA) denture base resin after thermocycling. Methods: Heat-polymerized PMMA discs (15 × 2 mm) with a total sample size n = 160 were studied. Specimens were categorized into two main groups (N = 80): conventional water-bath-polymerized PMMA (CP/PMMA) and autoclave-polymerized PMMA (AP/PMMA). Each group was subdivided according to the ND concentration into four groups (n = 20): unmodified PMMA as a control, and 0.1%, 0.25%, and 0.5% ND–PMMA. Scanning electron microscopy (SEM) was used to inspect the morphology of the ND and the ND–PMMA mixtures before heat polymerization. The specimens were exposed to thermal cycling (5000 cycles at 5 and 55 °C), then surface roughness was measured with a non-contact optical interferometric profilometer, contact angle with an automated goniometer, and translucency using a spectrophotometer. Colony-forming units (CFU) were used to determine the adherence of Candida albicans cells to the specimens. ANOVA and Tukey post hoc tests for pairwise comparison were utilized for the statistical analysis (α = 0.05). Results: Surface roughness was significantly reduced with ND addition to CP/PMMA (p ˂ 0.001), while the reduction was not statistically significant in AP/PMMA (p = 0.831). The addition of ND significantly reduced the contact angle, translucency, and Candida albicans count of CP/PMMA and AP/PMMA (p ˂ 0.001). The incorporation of ND in conjunction with autoclave polymerization of PMMA showed significant reduction in all tested properties (surface roughness, contact angle and Candida albicans adherence) except translucency (p = 0.726). Conclusions: ND addition to PMMA and autoclave polymerization improved the surface properties with respect to antifungal activities, while the translucency was adversely affected.
Collapse
Affiliation(s)
- Shaimaa M. Fouda
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia; (M.M.G.); (P.E.); (M.A.A.G.); (F.A.A.-H.)
- Correspondence:
| | - Mohammed M. Gad
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia; (M.M.G.); (P.E.); (M.A.A.G.); (F.A.A.-H.)
| | - Passent Ellakany
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia; (M.M.G.); (P.E.); (M.A.A.G.); (F.A.A.-H.)
| | - Maram A. Al Ghamdi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia; (M.M.G.); (P.E.); (M.A.A.G.); (F.A.A.-H.)
| | - Soban Q. Khan
- Department of Dental Education, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia;
| | - Sultan Akhtar
- Department of Biophysics, Institute for Research and Medical Consultations, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia;
| | - Doaa M. Al Eraky
- Department of Biomedical Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia;
| | - Fahad A. Al-Harbi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia; (M.M.G.); (P.E.); (M.A.A.G.); (F.A.A.-H.)
| |
Collapse
|
7
|
Unver S, Yildirim AZ. Evaluation of flexural properties and dynamic mechanical analysis of glass fiber-reinforced polyamide resin. Eur Oral Res 2021; 55:116-123. [PMID: 34746782 PMCID: PMC8547749 DOI: 10.26650/eor.2021872015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2020] [Revised: 01/04/2021] [Accepted: 02/09/2021] [Indexed: 11/20/2022] Open
Abstract
Purpose: The aim of this study was to evaluate flexural strength, elastic modulus and dynamic
mechanical analysis (DMA) of heat-polymerized polymethyl methacrylate resin,
polyamide resin and glass fiber-reinforced polyamide resin. Materials and methods: Three groups were determined according to denture base materials as polymethyl
methacrylate resin (H), polyamide resin (P) and glass fiber reinforced polyamide
resin (R). Sixteen specimens for each denture base material were prepared with
dimensions of 64x10x3.3 mm for three-point bending test. Two specimens for each
denture base material were prepared with dimensions of 30x10x3 mm for DMA.
Polymethyl methacrylate and polyamide specimens were prepared according to
the manufacturer’s recommendations. The silane was applied to glass fibers (4.5
mm length) 2% by weight of the polyamide resin, they were placed in polyamide
resin cartilages and injected to the mold. The thermal aging procedure was applied
to half of specimens of each material (n=8). Flexural strength and elastic modulus
of the specimens were determined by three-point bending test at a speed of 5 mm/
min. DMA was performed to 1 specimen from each group to evaluate viscoelastic
properties. Data were analyzed with one-way ANOVA, Tukey and Paired t tests. Results: A statistically significant difference was found in flexural strength and elastic
modulus values of denture base materials (p=0.00). The highest flexural strength
and elastic modulus values were observed in polymethyl methacrylate group.
There was no significant difference between polyamide and glass-fiber reinforced
polyamide groups (p=0.497). No significant difference was determined in all threedenture
base materials before and after aging procedure. Conclusion: The reinforcement with glass-fibers did not affect the flexural strength and elastic
modulus of polyamide resin.
Collapse
Affiliation(s)
- Senem Unver
- Department of Prosthodontics, Faculty of Dentistry, Gazi University, Ankara,Turkey
| | - Arzu Zeynep Yildirim
- Department of Prosthodontics, Faculty of Dentistry, Gazi University, Ankara,Turkey
| |
Collapse
|
8
|
Gad MM, Fouda SM, Abualsaud R, Alshahrani FA, Al-Thobity AM, Khan SQ, Akhtar S, Ateeq IS, Helal MA, Al-Harbi FA. Strength and Surface Properties of a 3D-Printed Denture Base Polymer. J Prosthodont 2021; 31:412-418. [PMID: 34347351 DOI: 10.1111/jopr.13413] [Citation(s) in RCA: 72] [Impact Index Per Article: 24.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/29/2021] [Indexed: 11/28/2022] Open
Abstract
PURPOSE This in vitro study evaluated the flexural strength, impact strength, hardness, and surface roughness of 3D-printed denture base resin subjected to thermal cycling treatment. MATERIALS AND METHODS According to ISO 20795-1:2013 standards, 120 acrylic resin specimens (40/flexural strength test, 40/impact strength, and 40/surface roughness and hardness test, n = 10) were fabricated and distributed into two groups: heat-polymerized; (Major.Base.20) as control and 3D-printed (NextDent) as experimental group. Half of the specimens of each group were subjected to 10,000 thermal cycles of 5 to 55°C simulating 1 year of clinical use. Flexural strength (MPa), impact strength (KJ/m2 ), hardness (VHN), and surface roughness (μm) were measured using universal testing machine, Charpy's impact tester, Vickers hardness tester, and profilometer, respectively. Data were analyzed by ANOVA and Tukey honestly significant difference (HSD) test (α = 0.05). RESULTS The values of flexural strength (MPa) were 86.63 ± 1.0 and 69.15 ± 0.88; impact strength (KJ/m2 )-6.32 ± 0.50 and 2.44 ± 0.31; hardness (VHN)-41.63 ± 2.03 and 34.62 ± 2.1; and surface roughness (μm)-0.18 ± 0.01 and 0.12 ± 0.02 for heat-polymerized and 3D-printed denture base materials, respectively. Significant differences in all tested properties were recorded between heat-polymerized and 3D-printed denture base materials (P < 0.001). Thermal cycling significantly lowered the flexural strength (63.93 ± 1.54 MPa), impact strength (2.40 ± 0.35 KJ/m2 ), and hardness (30.17 ± 1.38 VHN) of 3D-printed resin in comparison to thermal cycled heat-polymerized resin, but surface roughness showed non-significant difference (p = 0.262). CONCLUSION 3D-printed resin had inferior flexural strength, impact strength, and hardness values than heat-polymerized resin, but showed superior surface roughness. Temperature changes (thermal cycling) significantly reduced the hardness and flexural strength and increased surface roughness, but did not affect the impact strength.
Collapse
Affiliation(s)
- Mohammed M Gad
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Shaimaa M Fouda
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Reem Abualsaud
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Faris A Alshahrani
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Ahmad M Al-Thobity
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Soban Q Khan
- Department of Dental Education, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Sultan Akhtar
- Department of Biophysics, Institute for Research and Medical Consultations (IRMC), Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Ijlal Shahrukh Ateeq
- Biomedical Engineering department, College of Engineering, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Mohamed A Helal
- Department of Removable Prosthodontics, Faculty of Dentistry, Al-Azhar University, Cairo, Egypt
| | - Fahad A Al-Harbi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| |
Collapse
|
9
|
In Vitro Assessment of Artificial Aging on the Antifungal Activity of PMMA Denture Base Material Modified with ZrO 2 Nanoparticles. Int J Dent 2021; 2021:5560443. [PMID: 34093706 PMCID: PMC8137292 DOI: 10.1155/2021/5560443] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Revised: 04/26/2021] [Accepted: 04/30/2021] [Indexed: 12/21/2022] Open
Abstract
The antifungal effect of zirconium dioxide nanoparticles (ZrO2NPs) incorporated into denture base material has been inadequately investigated; additionally, to the authors' knowledge, no studies have assessed the influence of artificial aging on the antifungal activity of these particles. Methodology. Heat-polymerized acrylic resin disks were fabricated and divided into four groups (0%, 1%, 2.5%, and 5% ZrO2NPs by weight). Antifungal activity was assessed using the direct culture and disk diffusion methods. Surface roughness and contact angles were measured using a profilometer and a goniometer, respectively. The artificial aging procedure was performed by repeating all tests at 7, 14, and 30 days following 2 rounds of thermocycling. Data were analyzed using ANOVA and Tukey's post-hoc test (p < 0.05). Results. The addition of ZrO2NPs significantly decreased the adhesion of Candida albicans with and without artificial aging procedures (p < 0.001), while the disk diffusion methods did not reveal inhibition zones. ZrO2NP-modified specimens displayed significantly higher surface roughness compared to specimens in the control group (p < 0.05) and showed the same behaviors with artificial aging procedures. The contact angle was significantly decreased in all modified groups in comparison to the control group (p < 0.05). Conclusion. The addition of ZrO2NPs to polymethylmethacrylate denture base material reduced the adhesion of Candida albicans with a long-term antifungal effect. With the addition of ZrO2NPs, contact angles were decreased and surface roughness was increased; 1% was the most appropriate concentration. Clinical significance. The addition of ZrO2NPs to denture base material confers a long-term antifungal effect and could be used as a possible method for preventing and treating denture stomatitis.
Collapse
|
10
|
Influence of Different Repair Acrylic Resin and Thermocycling on the Flexural Strength of Denture Base Resin. ACTA ACUST UNITED AC 2020; 56:medicina56020050. [PMID: 31973219 PMCID: PMC7074266 DOI: 10.3390/medicina56020050] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2019] [Revised: 01/12/2020] [Accepted: 01/15/2020] [Indexed: 11/16/2022]
Abstract
Background and Objectives: Fractured acrylic denture base is a common occurrence in clinical practice. The effective denture repair procedure is cost-effective, time conserving, and results in lesser time without denture for the patient. Along with various reinforcements and surface modifications; different acrylic resins are investigated in improving the flexural strength of the fractured site. The aim of this study was to evaluate the flexural strength of a polymethyl methacrylate (PMMA) denture base repaired with heat-polymerized (HPA), auto-polymerized (APA) and light-polymerized acrylic (LPA) resins after thermocycling. Materials and Methods: Forty rectangular shaped (50 mm × 25 mm × 3 mm) PMMA specimens were fabricated. Group 1 specimens (n = 10) were kept as controls and the remaining 30 samples were sectioned at the center with a repair site dimension of 3 mm. The samples from three groups (n = 10) were repaired with HPA, APA, and LPA resins, respectively. The specimens were thermocycled for 5000 cycles and subjected to a three-point flexural test. The maximum load required to fracture the specimens was recorded, and further analyzed with ANOVA and the Games-Howell Post hoc test at the significance level p = 0.05. Results: The average maximum load and flexural strength of the control group was 173.60 N and 13.02 Mpa and corresponding values for denture repaired with HPA was 87.36 N and 6.55 Mpa. The corresponding values for APA resin and LPA resins were 62.94 N, 57.51 N, and 4.72 Mpa, 4.06 Mpa, respectively. Conclusions: The PMMA specimens repaired with HPA resins resulted in a significantly higher load to fracture compared to APA resin and LPA resin.
Collapse
|