Lee YM, Ordaz A, Durcanova B, Viner JA, Theodosopoulos PV, Aghi MK, McDermott MW. Cerebrospinal Fluid Leaks and Pseudomeningocele after Posterior Fossa Surgery: Effect of an Autospray Dural Sealant.
Cureus 2020;
12:e8379. [PMID:
32626623 PMCID:
PMC7328695 DOI:
10.7759/cureus.8379]
[Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Background
Posterior fossa craniotomies can be complicated by cerebrospinal fluid (CSF) leaks, infection, meningitis, neurologic deficits, and intracranial hypotension caused by defective closure of the dura. Secondary dural closures such as pericranial graft, muscle graft, glue, sealants, or fat graft are used. However, there have been few studies examining the use of sealants with a polyethylene glycol and polyethylenimine component.
Objective
We studied the effect of one such sealant, Adherus® (HyperBranch Medical Technology, Durham, NC, USA), as an adjunct to secondary closure methods in the reduction of the use of abdominal fat grafting and lumbar puncture/drains.
Methods
We retrospectively reviewed the surgical records of all patients undergoing posterior fossa cranial surgery during a two-year period at a tertiary university affiliated medical center.
Results
Overall, data a total of 122 patients (62 in the no Adherus and 60 in the Adherus group) were collected. There was no statistically significant difference in the 30-day incisional CSF leak rate (4.1% vs. 6.5%; p=0.183), 30-day non-incisional CSF leak rate (11.3% vs. 5.0%; p=0.205), and 30-day pseudomeningocele rate (16.1% vs. 13.3%; p=0.663) in the no Adherus and Adherus groups, respectively. However, there was a significant reduction in the use of abdominal fat grafting (0% vs. 30.7%; p<0.001) and intraoperative CSF diversion techniques (58.1% vs. 23.3%; p<0.001). Every instance of the use of Adherus saved on average, $809.36.
Conclusions
A statistically significant reduction in the use of CSF shunting procedures during posterior fossa craniotomy/craniectomy was achieved after the introduction of Adherus with no increase in CSF leak rate.
Collapse