1
|
Morris L, Tierney P, Hynes N, Sultan S. An in vitro Assessment of the Haemodynamic Features Occurring Within the True and False Lumens Separated by a Dissection Flap for a Patient-Specific Type B Aortic Dissection. Front Cardiovasc Med 2022; 9:797829. [PMID: 35369331 PMCID: PMC8968342 DOI: 10.3389/fcvm.2022.797829] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2021] [Accepted: 02/15/2022] [Indexed: 11/14/2022] Open
Abstract
One of the highest mortality rates of cardiovascular diseases is aortic dissections with challenging treatment options. Currently, less study has been conducted in developing in vitro patient-specific Type B aortic dissection models, which mimic physiological flow conditions along the true and false lumens separated by a dissection flap with multiple entry and exit tears. A patient-specific Stanford Type B aortic dissection scan was replicated by an in-house manufactured automatic injection moulding system and a novel modelling technique for creating the ascending aorta, aortic arch, and descending aorta incorporating arterial branching, the true/false lumens, and dissection flap with entry and exit intimal tears. The physiological flowrates and pressure values were monitored, which identified jet stream fluid flows entering and exiting the dissection tears. Pressure in the aorta’s true lumen region was controlled at 125/85 mmHg for systolic and diastolic values. Pressure values were obtained in eight sections along the false lumen using a pressure transducer. The true lumen systolic pressure varied from 122 to 128 mmHg along the length. Flow patterns were monitored by ultrasound along 12 sections. Detailed images obtained from the ultrasound transducer probe showed varied flow patterns with one or multiple jet steam vortices along the aorta model. The dissection flap movement was assessed at four sections of the patient-specific aorta model. The displacement values of the flap varied from 0.5 to 3 mm along the model. This model provides a unique insight into aortic dissection flow patterns and pressure distributions. This dissection phantom model can be used to assess various treatment options based on the surgical, endovascular, or hybrid techniques.
Collapse
Affiliation(s)
- Liam Morris
- Galway-Mayo Institute of Technology, Galway, Ireland
- Galway Medical Technology Centre, Department of Mechanical and Industrial Engineering, Galway-Mayo Institute of Technology, Galway, Ireland
- Medical and Engineering Technology Centre, Department of Mechanical and Industrial Engineering, Galway-Mayo Institute of Technology, Galway, Ireland
- Lero – Science Foundation Ireland Research Centre for Software, Galway-Mayo Institute of Technology, Galway, Ireland
- *Correspondence: Liam Morris,
| | - Paul Tierney
- Galway Medical Technology Centre, Department of Mechanical and Industrial Engineering, Galway-Mayo Institute of Technology, Galway, Ireland
- Medical and Engineering Technology Centre, Department of Mechanical and Industrial Engineering, Galway-Mayo Institute of Technology, Galway, Ireland
| | - Niamh Hynes
- CÚRAM, National University of Ireland, Galway, Ireland
| | - Sherif Sultan
- Western Vascular Institute, Department of Vascular and Endovascular Surgery, University College Hospital Galway, Galway, Ireland
- Department of Vascular and Endovascular Surgery, Galway Clinic, Royal College of Surgeons in Ireland, Doughiska, Ireland
| |
Collapse
|
2
|
Pettersen EM, Avdal J, Fiorentini S, Salvesen Ø, Hisdal J, Torp H, Seternes A. Validation of a novel ultrasound Doppler monitoring device (earlybird) for measurements of volume flow rate in arteriovenous fistulas for hemodialysis. J Vasc Access 2021; 24:11297298211060960. [PMID: 34852698 DOI: 10.1177/11297298211060960] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
BACKGROUND Controversy exists regarding surveillance of arteriovenous fistulas for hemodialysis to increase patency. A significant reduction in volume flow rate (VFR) should lead to diagnostic evaluation and eventually intervention. Several methods are available for VFR measurements, but all of them are associated with low reproducibility. VFR trend analysis is suggested as an improved solution. It is therefore a need to find user-friendly, cost and time-effective modalities. We present a novel Doppler ultrasound device (earlybird) which could bridge this gap. It includes an easy-to-use and light-weight single element transducer. METHODS In an experimental and clinical setting, we compared earlybird to duplex ultrasound to assess VFR. In a closed circuit of blood-mimicking fluid, 36 paired calculations of calibrated, duplex ultrasound and earlybird VFR was measured. In addition, 23 paired recordings of duplex ultrasound and earlybird VFR was measured in 16 patients with underarm arteriovenous fistulas. Pearson correlation, intraclass correlation coefficient, root-mean-square and Bland-Altman plots were analyzed. RESULTS Strong correlation (r = 0.991, p < 0.001), and excellent level of agreement (ICC = 0.970 (95% CI 0.932 - 0.985), p < 0.001) between earlybird and the calibrated VFR was found in the experimental setup. This was confirmed in the clinical setting, with a strong correlation (r = 0.781, p < 0.001) and moderate to good level of agreement (ICC = 0.750 (95% CI 0.502-0.885), p < 0.001) between earlybird and duplex ultrasound VFR measured at the arteriovenous fistulas outflow veins. In the Bland-Altman plot-analysis for the experimental setup, we found smaller limits of agreement, a smaller consistent and proportional bias, as well as greater accuracy of earlybird than DUS when compared to the calibrated VFR. CONCLUSION Earlybird is a feasible tool for VFR measurements and could be a future promising device for easy assessment and surveillance of AVF for hemodialysis.
Collapse
Affiliation(s)
- Erik Mulder Pettersen
- Department of Circulation and Medical Imaging, Norwegian University of Science and Technology, Trondheim, Norway
- Department of Surgery, Sørlandet Hospital Kristiansand, Kristiansand, Norway
- Section of Vascular Surgery, Department of Surgery, Trondheim University Hospital, St. Olavs Hospital, Trondheim, Norway
| | - Jørgen Avdal
- Department of Circulation and Medical Imaging, Norwegian University of Science and Technology, Trondheim, Norway
| | - Stefano Fiorentini
- Department of Circulation and Medical Imaging, Norwegian University of Science and Technology, Trondheim, Norway
| | - Øyvind Salvesen
- Clinical Research Unit, Department of Clinical and Molecular Medicine, Norwegian University of Science and Technology, Trondheim, Norway
| | - Jonny Hisdal
- Section of Vascular Investigations, Division of Cardiovascular and Pulmonary Diseases, Department of Vascular Surgery, Oslo University Hospital, Oslo, Norway
- Institute of Clinical Medicine, Faculty of Medicine, University of Oslo, Oslo, Norway
| | - Hans Torp
- Department of Circulation and Medical Imaging, Norwegian University of Science and Technology, Trondheim, Norway
- CIMON Medical, NTNU Technology Transfer AS, Trondheim, Norway
| | - Arne Seternes
- Department of Circulation and Medical Imaging, Norwegian University of Science and Technology, Trondheim, Norway
- Section of Vascular Surgery, Department of Surgery, Trondheim University Hospital, St. Olavs Hospital, Trondheim, Norway
| |
Collapse
|
3
|
Moulakakis KG, Kakisis J, Gonidaki E, Lazaris AM, Tsangaris S, Geroulakos G, Manopoulos C. Comparison of Fluid Dynamics Variations Between Chimney and Fenestrated Endografts for Pararenal Aneurysms Repair: A Patient Specific Computational Study as Motivation for Clinical Decision-Making. Vasc Endovascular Surg 2019; 53:572-582. [PMID: 31382837 DOI: 10.1177/1538574419867531] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND-AIM Limited data exist concerning the fluid dynamic changes induced by endovascular aortic repair with fenestrated and chimney graft modalities in pararenal aneurysms. We aimed to investigate and compare the wall shear stress (WSS) and flow dynamics for the branch vessels before and after endovascular aortic repair with fenestrated and chimney techniques. METHODS Modeling was done for patient specific pararenal aortic aneurysms employing fenestrated and chimney grafts (Materialise Mimics 10.0) before and after the endovascular procedure, using computed tomography scans of patients. Surface and spatial grids were created using the ANSYS CFD meshing software 2019 R2. Assessment of blood flow, streamlines, and WSS before and after aneurysm repair was performed. RESULTS The endovascular repair with chimney grafts leaded to a 43% to 53% reduction in perfusion in renal arteries. In fenestrated reconstruction, we observed a 15% reduced perfusion in both renal arteries. In both cases, we observed a decrease in the recirculation phenomena of the aorta after endovascular repair. Concerning the grafts of the renal arteries, we observed in both the transverse and longitudinal axes low WSS regions with simultaneous recirculation of the flow 1 cm distal to the ostium sites in both aortic graft models. High WSS regions appeared in the sites of ostium. CONCLUSIONS We observed reduced renal perfusion in chimney grafts compared to fenestrated grafts, probably caused by the long and kinked characteristics of these devices.
Collapse
Affiliation(s)
- Konstantinos G Moulakakis
- 1 Department of Vascular Surgery, Medical School, National and Kapodistrian University of Athens, Attikon University Hospital, Athens, Greece
| | - John Kakisis
- 1 Department of Vascular Surgery, Medical School, National and Kapodistrian University of Athens, Attikon University Hospital, Athens, Greece
| | - Eleni Gonidaki
- 2 Biofluid Mechanics and Biomedical Engineering Laboratory, Fluids Section, School of Mechanical Engineering, National Technical University of Athens, Greece
| | - Andreas M Lazaris
- 1 Department of Vascular Surgery, Medical School, National and Kapodistrian University of Athens, Attikon University Hospital, Athens, Greece
| | - Sokrates Tsangaris
- 2 Biofluid Mechanics and Biomedical Engineering Laboratory, Fluids Section, School of Mechanical Engineering, National Technical University of Athens, Greece
| | - George Geroulakos
- 1 Department of Vascular Surgery, Medical School, National and Kapodistrian University of Athens, Attikon University Hospital, Athens, Greece
| | - Christos Manopoulos
- 2 Biofluid Mechanics and Biomedical Engineering Laboratory, Fluids Section, School of Mechanical Engineering, National Technical University of Athens, Greece
| |
Collapse
|
4
|
Abstract
Accurate estimation of ultrasound Doppler spectrogram envelope is essential for clinical pathological diagnosis of various cardiovascular diseases. However, due to intrinsic spectral broadening in the power spectrum and speckle noise existing in ultrasound images, it is difficult to obtain the accurate maximum velocity. Each of the standard existing methods has their own limitations and does not work well in complicated recordings. This paper proposes a robust automatic spectral envelope estimation method that is more accurate in phantom recordings and various in-vivo recordings than the currently used methods. Comparisons were performed on phantom recordings of the carotid artery with varying noise and additional in-vivo recordings. The accuracy of the proposed method was on average 8% greater than the existing methods. The experimental results demonstrate the wide applicability under different blood conditions and the robustness of the proposed algorithm.
Collapse
|
5
|
Linares-Palomino JP. Still lack evidence to predict maturation of autologous arteriovenous fistula for hemodialysis. Eur J Vasc Endovasc Surg 2018; 56:582. [PMID: 30139573 DOI: 10.1016/j.ejvs.2018.07.031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2018] [Accepted: 07/26/2018] [Indexed: 10/28/2022]
Affiliation(s)
- Jose P Linares-Palomino
- University Hospital Virgen de las Nieves, Vascular Surgery Unit, Academic Department of Surgery, Avda. Fuerzas Armadas n°2, 18014 Granada, Spain.
| |
Collapse
|
6
|
Jensen J, Hoyos CAV, Traberg MS, Olesen JB, Tomov BG, Moshavegh R, Holbek S, Stuart MB, Ewertsen C, Hansen KL, Thomsen C, Nielsen MB, Jensen JA. Accuracy and Precision of a Plane Wave Vector Flow Imaging Method in the Healthy Carotid Artery. ULTRASOUND IN MEDICINE & BIOLOGY 2018; 44:1727-1741. [PMID: 29735315 DOI: 10.1016/j.ultrasmedbio.2018.03.017] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/28/2017] [Revised: 03/04/2018] [Accepted: 03/19/2018] [Indexed: 06/08/2023]
Abstract
The objective of the study described here was to investigate the accuracy and precision of a plane wave 2-D vector flow imaging (VFI) method in laminar and complex blood flow conditions in the healthy carotid artery. The approach was to study (i) the accuracy for complex flow by comparing the velocity field from a computational fluid dynamics (CFD) simulation to VFI estimates obtained from the scan of an anthropomorphic flow phantom and from an in vivo scan; (ii) the accuracy for laminar unidirectional flow in vivo by comparing peak systolic velocities from VFI with magnetic resonance angiography (MRA); (iii) the precision of VFI estimation in vivo at several evaluation points in the vessels. The carotid artery at the bifurcation was scanned using both fast plane wave ultrasound and MRA in 10 healthy volunteers. The MRA geometry acquired from one of the volunteers was used to fabricate an anthropomorphic flow phantom, which was also scanned using the fast plane wave sequence. The same geometry was used in a CFD simulation to calculate the velocity field. Results indicated that similar flow patterns and vortices were estimated with CFD and VFI in the phantom for the carotid bifurcation. The root-mean-square difference between CFD and VFI was within 0.12 m/s for velocity estimates in the common carotid artery and the internal branch. The root-mean-square difference was 0.17 m/s in the external branch. For the 10 volunteers, the mean difference between VFI and MRA was -0.17 m/s for peak systolic velocities of laminar flow in vivo. The precision in vivo was calculated as the mean standard deviation (SD) of estimates aligned to the heart cycle and was highest in the center of the common carotid artery (SD = 3.6% for velocity magnitudes and 4.5° for angles) and lowest in the external branch and for vortices (SD = 10.2% for velocity magnitudes and 39° for angles). The results indicate that plane wave VFI measures flow precisely and that estimates are in good agreement with a CFD simulation and MRA.
Collapse
Affiliation(s)
- Jonas Jensen
- Center for Fast Ultrasound Imaging, Department of Electrical Engineering, Technical University of Denmark, Lyngby, Denmark.
| | | | - Marie Sand Traberg
- Center for Fast Ultrasound Imaging, Department of Electrical Engineering, Technical University of Denmark, Lyngby, Denmark
| | - Jacob Bjerring Olesen
- Center for Fast Ultrasound Imaging, Department of Electrical Engineering, Technical University of Denmark, Lyngby, Denmark
| | - Borislav Gueorguiev Tomov
- Center for Fast Ultrasound Imaging, Department of Electrical Engineering, Technical University of Denmark, Lyngby, Denmark
| | - Ramin Moshavegh
- Center for Fast Ultrasound Imaging, Department of Electrical Engineering, Technical University of Denmark, Lyngby, Denmark
| | - Simon Holbek
- Center for Fast Ultrasound Imaging, Department of Electrical Engineering, Technical University of Denmark, Lyngby, Denmark
| | - Matthias Bo Stuart
- Center for Fast Ultrasound Imaging, Department of Electrical Engineering, Technical University of Denmark, Lyngby, Denmark
| | - Caroline Ewertsen
- Department of Radiology, Copenhagen University Hospital, Copenhagen, Denmark
| | | | - Carsten Thomsen
- Department of Radiology, Copenhagen University Hospital, Copenhagen, Denmark
| | | | - Jørgen Arendt Jensen
- Center for Fast Ultrasound Imaging, Department of Electrical Engineering, Technical University of Denmark, Lyngby, Denmark
| |
Collapse
|
7
|
Marr K, Jakimovski D, Mancini M, Carl E, Zivadinov R. Jugular Venous Flow Quantification Using Doppler Sonography. ULTRASOUND IN MEDICINE & BIOLOGY 2018; 44:1762-1769. [PMID: 29784437 PMCID: PMC6026550 DOI: 10.1016/j.ultrasmedbio.2018.04.010] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/17/2018] [Revised: 03/30/2018] [Accepted: 04/15/2018] [Indexed: 06/08/2023]
Abstract
A consensus on venous flow quantification using echo spectral Doppler sonography is lacking. Doppler sonography data from 83 healthy individuals were examined using manually traced transverse cross-sectional area and diameter-derived cross-sectional area obtained in longitudinal view measurements of the internal jugular vein. Time-averaged velocity over a 4-s interval was obtained in the longitudinal plane using manual tracing of the waveform. Manual and computer-generated blood flow volume calculations were also obtained for the common carotid artery, for accuracy purposes. No differences were detected between semi-automated and manual blood flow volume calculations for the common carotid artery. The manual calculation method resulted in almost twofold larger venous internal jugular vein flow measurements compared with the semi-automated method. Doppler sonography equipment does not provide accurate automated calculation of venous size and blood flow. Until further technological development occurs, manual calculation of venous blood flow is warranted.
Collapse
Affiliation(s)
- Karen Marr
- Buffalo Neuroimaging Analysis Center, Department of Neurology, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, State University of New York, Buffalo, New York, USA
| | - Dejan Jakimovski
- Buffalo Neuroimaging Analysis Center, Department of Neurology, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, State University of New York, Buffalo, New York, USA
| | - Marcello Mancini
- Institute of Biostructure and Bioimaging, National Research Council of Italy, Rome, Italy
| | - Ellen Carl
- Buffalo Neuroimaging Analysis Center, Department of Neurology, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, State University of New York, Buffalo, New York, USA
| | - Robert Zivadinov
- Buffalo Neuroimaging Analysis Center, Department of Neurology, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, State University of New York, Buffalo, New York, USA; Center for Biomedical Imaging at Clinical Translational Science Institute, University at Buffalo, State University of New York, Buffalo, New York, USA.
| |
Collapse
|
8
|
Zhou X, Xia C, Stephen G, Khan F, Corner GA, Hoskins PR, Huang Z. Investigation of Ultrasound-Measured Flow Velocity, Flow Rate and Wall Shear Rate in Radial and Ulnar Arteries Using Simulation. ULTRASOUND IN MEDICINE & BIOLOGY 2017; 43:981-992. [PMID: 28236532 DOI: 10.1016/j.ultrasmedbio.2016.12.015] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/28/2016] [Revised: 12/02/2016] [Accepted: 12/31/2016] [Indexed: 06/06/2023]
Abstract
Parameters of blood flow measured by ultrasound in radial and ulnar arteries, such as flow velocity, flow rate and wall shear rate, are widely used in clinical practice and clinical research. Investigation of these measurements is useful for evaluating accuracy and providing knowledge of error sources. A method for simulating the spectral Doppler ultrasound measurement process was developed with computational fluid dynamics providing flow-field data. Specific scanning factors were adjusted to investigate their influence on estimation of the maximum velocity waveform, and flow rate and wall shear rate were derived using the Womersley equation. The overestimation in maximum velocity increases greatly (peak systolic from about 10% to 30%, time-averaged from about 30% to 50%) when the beam-vessel angle is changed from 30° to 70°. The Womersley equation was able to estimate flow rate in both arteries with less than 3% error, but performed better in the radial artery (2.3% overestimation) than the ulnar artery (15.4% underestimation) in estimating wall shear rate. It is concluded that measurements of flow parameters in the radial and ulnar arteries with clinical ultrasound scanners are prone to clinically significant errors.
Collapse
Affiliation(s)
- Xiaowei Zhou
- School of Science and Engineering, University of Dundee, Dundee, United Kingdom
| | - Chunming Xia
- School of Mechanical and Power Engineering, East China University of Science and Technology, Shanghai, China; NHS Tayside Medical Physics, Ninewells Hospital, Dundee, United Kingdom
| | - Gandy Stephen
- School of Mechanical and Power Engineering, East China University of Science and Technology, Shanghai, China; NHS Tayside Medical Physics, Ninewells Hospital, Dundee, United Kingdom
| | - Faisel Khan
- Cardiovascular and Diabetes Medicine, Ninewells Hospital and Medical School, University of Dundee, Dundee, United Kingdom
| | - George A Corner
- School of Science and Engineering, University of Dundee, Dundee, United Kingdom
| | - Peter R Hoskins
- Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, United Kingdom
| | - Zhihong Huang
- School of Science and Engineering, University of Dundee, Dundee, United Kingdom.
| |
Collapse
|
9
|
Ricci S, Swillens A, Ramalli A, Segers P, Tortoli P. Wall Shear Rate Measurement: Validation of a New Method Through Multiphysics Simulations. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2017; 64:66-77. [PMID: 28092504 DOI: 10.1109/tuffc.2016.2608442] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Wall shear stress is known to affect the vessel endothelial function and to be related to important pathologies like the development of atherosclerosis. It is defined as the product of the blood viscosity by the blood velocity gradient at the wall position, i.e., the wall shear rate (WSR). The WSR measurement is particularly challenging in important cardiovascular sites, like the carotid bifurcation, because of the related complex flow configurations characterized by high spatial and temporal gradients, wall movement, and clutter noise. Moreover, accuracy of any method for WSR measurement can be effectively tested only if reliable gold standard WSR values, considering all the aforementioned disturbing effects, are available. Unfortunately, these requirements are difficult to achieve in a physical phantom, so that the accuracy test of the novel WSR measurement methods was so far limited to straight pipes and/or similar idealistic configurations. In this paper, we propose a new method for WSR measurement and its validation based on a mathematical model of the carotid bifurcation, which, exploiting fluid-structure simulations, is capable of reproducing realistic flow configuration, wall movement, and clutter noise. In particular, the profile near the wall, not directly measurable because affected by clutter, is estimated through a power-law fitting and compared with the gold standard provided by the model. In this condition, the WSR measurements featured an accuracy of ±20 %. A preliminary test on a volunteer confirmed the feasibility of the WSR method for in vivo application.
Collapse
|
10
|
Van Cauwenberge J, Lovstakken L, Fadnes S, Rodriguez-Morales A, Vierendeels J, Segers P, Swillens A. Assessing the Performance of Ultrafast Vector Flow Imaging in the Neonatal Heart via Multiphysics Modeling and In Vitro Experiments. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2016; 63:1772-1785. [PMID: 27824560 DOI: 10.1109/tuffc.2016.2596804] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Ultrafast vector flow imaging would benefit newborn patients with congenital heart disorders, but still requires thorough validation before translation to clinical practice. This paper investigates 2-D speckle tracking (ST) of intraventricular blood flow in neonates when transmitting diverging waves at ultrafast frame rate. Computational and in vitro studies enabled us to quantify the performance and identify artifacts related to the flow and the imaging sequence. First, synthetic ultrasound images of a neonate's left ventricular flow pattern were obtained with the ultrasound simulator Field II by propagating point scatterers according to 3-D intraventricular flow fields obtained with computational fluid dynamics (CFD). Noncompounded diverging waves (opening angle of 60°) were transmitted at a pulse repetition frequency of 9 kHz. ST of the B-mode data provided 2-D flow estimates at 180 Hz, which were compared with the CFD flow field. We demonstrated that the diastolic inflow jet showed a strong bias in the lateral velocity estimates at the edges of the jet, as confirmed by additional in vitro tests on a jet flow phantom. Furthermore, ST performance was highly dependent on the cardiac phase with low flows (<5 cm/s), high spatial flow gradients, and out-of-plane flow as deteriorating factors. Despite the observed artifacts, a good overall performance of 2-D ST was obtained with a median magnitude underestimation and angular deviation of, respectively, 28% and 13.5° during systole and 16% and 10.5° during diastole.
Collapse
|
11
|
Kathpalia A, Karabiyik Y, Eik-Nes SH, Tegnander E, Ekroll IK, Kiss G, Torp H. Adaptive Spectral Envelope Estimation for Doppler Ultrasound. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2016; 63:1825-1838. [PMID: 27824563 DOI: 10.1109/tuffc.2016.2587381] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Estimation of accurate maximum velocities and spectral envelope in ultrasound Doppler blood flow spectrograms are both essential for clinical diagnostic purposes. However, obtaining accurate maximum velocity is not straightforward due to intrinsic spectral broadening and variance in the power spectrum estimate. The method proposed in this paper for maximum velocity point detection has been developed by modifying an existing method-signal noise slope intersection, incorporating in it steps from an altered version of another method called geometric method. Adaptive noise estimation from the spectrogram ensures that a smooth spectral envelope is obtained postdetection of these maximum velocity points. The method has been tested on simulated Doppler signal with scatterers possessing a parabolic flow velocity profile constant in time, steady and pulsatile string phantom recordings, as well as in vivo recordings from uterine, umbilical, carotid, and subclavian arteries. The results from simulation experiments indicate a bias of less than 2.5% in maximum velocities when estimated for a range of peak velocities, Doppler angles, and SNR levels. Standard deviation in the envelope is low-less than 2% in the case of experiments done by varying the peak velocity and Doppler angle for steady phantom and simulated flow, and also less than 2% in the case of experiments done by varying SNR but keeping constant flow conditions for in vivo and simulated flow. Low variability in the envelope makes the prospect of using the envelope for automated blood flow measurements possible and is illustrated for the case of pulsatility index estimation in uterine and umbilical arteries.
Collapse
|
12
|
Jensen J, Olesen JB, Stuart MB, Hansen PM, Nielsen MB, Jensen JA. Vector velocity volume flow estimation: Sources of error and corrections applied for arteriovenous fistulas. ULTRASONICS 2016; 70:136-146. [PMID: 27164045 DOI: 10.1016/j.ultras.2016.04.023] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/16/2015] [Revised: 04/13/2016] [Accepted: 04/29/2016] [Indexed: 06/05/2023]
Abstract
A method for vector velocity volume flow estimation is presented, along with an investigation of its sources of error and correction of actual volume flow measurements. Volume flow errors are quantified theoretically by numerical modeling, through flow phantom measurements, and studied in vivo. This paper investigates errors from estimating volumetric flow using a commercial ultrasound scanner and the common assumptions made in the literature. The theoretical model shows, e.g. that volume flow is underestimated by 15%, when the scan plane is off-axis with the vessel center by 28% of the vessel radius. The error sources were also studied in vivo under realistic clinical conditions, and the theoretical results were applied for correcting the volume flow errors. Twenty dialysis patients with arteriovenous fistulas were scanned to obtain vector flow maps of fistulas. When fitting an ellipsis to cross-sectional scans of the fistulas, the major axis was on average 10.2mm, which is 8.6% larger than the minor axis. The ultrasound beam was on average 1.5mm from the vessel center, corresponding to 28% of the semi-major axis in an average fistula. Estimating volume flow with an elliptical, rather than circular, vessel area and correcting the ultrasound beam for being off-axis, gave a significant (p=0.008) reduction in error from 31.2% to 24.3%. The error is relative to the Ultrasound Dilution Technique, which is considered the gold standard for volume flow estimation for dialysis patients. The study shows the importance of correcting for volume flow errors, which are often made in clinical practice.
Collapse
Affiliation(s)
- Jonas Jensen
- Center for Fast Ultrasound Imaging, Dept. of Elec. Eng., Bldg. 349, Technical University of Denmark, DK-2800 Lyngby, Denmark.
| | - Jacob Bjerring Olesen
- Center for Fast Ultrasound Imaging, Dept. of Elec. Eng., Bldg. 349, Technical University of Denmark, DK-2800 Lyngby, Denmark
| | - Matthias Bo Stuart
- Center for Fast Ultrasound Imaging, Dept. of Elec. Eng., Bldg. 349, Technical University of Denmark, DK-2800 Lyngby, Denmark
| | - Peter Møller Hansen
- Center for Fast Ultrasound Imaging, Dept. of Elec. Eng., Bldg. 349, Technical University of Denmark, DK-2800 Lyngby, Denmark; Department of Radiology, Copenhagen University Hospital, DK-2100 Copenhagen, Denmark
| | | | - Jørgen Arendt Jensen
- Center for Fast Ultrasound Imaging, Dept. of Elec. Eng., Bldg. 349, Technical University of Denmark, DK-2800 Lyngby, Denmark
| |
Collapse
|
13
|
Kenwright DA, Anderson T, Moran CM, Hoskins PR. Assessment of Spectral Doppler for an Array-Based Preclinical Ultrasound Scanner Using a Rotating Phantom. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:2232-2239. [PMID: 25957754 PMCID: PMC4510153 DOI: 10.1016/j.ultrasmedbio.2015.04.006] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/24/2015] [Revised: 03/24/2015] [Accepted: 04/06/2015] [Indexed: 06/04/2023]
Abstract
Velocity measurement errors were investigated for an array-based preclinical ultrasound scanner (Vevo 2100, FUJIFILM VisualSonics, Toronto, ON, Canada). Using a small-size rotating phantom made from a tissue-mimicking material, errors in pulse-wave Doppler maximum velocity measurements were observed. The extent of these errors was dependent on the Doppler angle, gate length, gate depth, gate horizontal placement and phantom velocity. Errors were observed to be up to 172% at high beam-target angles. It was found that small gate lengths resulted in larger velocity errors than large gate lengths, a phenomenon that has not previously been reported (e.g., for a beam-target angle of 0°, the error was 27.8% with a 0.2-mm gate length and 5.4% with a 0.98-mm gate length). The error in the velocity measurement with sample volume depth changed depending on the operating frequency of the probe. Some edge effects were observed in the horizontal placement of the sample volume, indicating a change in the array aperture size. The error in the velocity measurements increased with increased phantom velocity, from 22% at 2.4 cm/s to 30% at 26.6 cm/s. To minimise the impact of these errors, an angle-dependent correction factor was derived based on a simple ray model of geometric spectral broadening. Use of this angle-dependent correction factor reduces the maximum velocity measurement errors to <25% in all instances, significantly improving the current estimation of maximum velocity from pulse-wave Doppler ultrasound.
Collapse
Affiliation(s)
- David A Kenwright
- Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, United Kingdom.
| | - Tom Anderson
- Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, United Kingdom
| | - Carmel M Moran
- Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, United Kingdom
| | - Peter R Hoskins
- Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, United Kingdom
| |
Collapse
|
14
|
Ricci S, Matera R, Tortoli P. An improved Doppler model for obtaining accurate maximum blood velocities. ULTRASONICS 2014; 54:2006-2014. [PMID: 24934798 DOI: 10.1016/j.ultras.2014.05.012] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/05/2014] [Revised: 05/15/2014] [Accepted: 05/15/2014] [Indexed: 06/03/2023]
Abstract
Maximum blood velocity estimates are frequently required in diagnostic applications, including carotid stenosis evaluation, arteriovenous fistula inspection, and maternal-fetal examinations. However, the currently used methods for ultrasound measurements are inaccurate and often rely on applying heuristic thresholds to a Doppler power spectrum. A new method that uses a mathematical model to predict the correct threshold that should be used for maximum velocity measurements has recently been introduced. Although it is a valuable and deterministic tool, this method is limited to parabolic flows insonated by uniform pressure fields. In this work, a more generalized technique that overcomes such limitations is presented. The new approach, which uses an extended Doppler spectrum model, has been implemented in an experimental set-up based on a linear array probe that transmits defocused steered waves. The improved model has been validated by Field II simulations and phantom experiments on tubes with diameters between 2mm and 8mm. Using the spectral threshold suggested by the new model significantly higher accuracy estimates of the peak velocity can be achieved than are now clinically attained, including for narrow beams and non-parabolic velocity profiles. In particular, an accuracy of +1.2±2.5 cm/s has been obtained in phantom measurements for velocities ranging from 20 to 80 cm/s. This result represents an improvement that can significantly affect the way maximum blood velocity is investigated today.
Collapse
Affiliation(s)
- Stefano Ricci
- Information Engineering Department, University of Florence, Via S. Marta n. 3, 50139 Firenze, Italy.
| | - Riccardo Matera
- Information Engineering Department, University of Florence, Via S. Marta n. 3, 50139 Firenze, Italy
| | - Piero Tortoli
- Information Engineering Department, University of Florence, Via S. Marta n. 3, 50139 Firenze, Italy
| |
Collapse
|
15
|
Validation of Computational Fluid Dynamics-Based Analysis to Evaluate Hemodynamic Significance of access Stenosis. J Vasc Access 2014; 15:409-14. [DOI: 10.5301/jva.5000226] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/12/2014] [Indexed: 11/20/2022] Open
Abstract
Purpose Stenosis in a vascular access circuit is the predominant cause of access dysfunction. Hemodynamic significance of a stenosis identified by angiography in an access circuit is uncertain. This study utilizes computational fluid dynamics (CFD) to model flow through arteriovenous fistula to predict the functional significance of stenosis in vascular access circuits. Methods Three-dimensional models of fistulas were created with a range of clinically relevant stenoses using SolidWorks. Stenoses diameters ranged from 1.0 to 3.0 mm and lengths from 5 to 60 mm within a fistula diameter of 7 mm. CFD analyses were performed using a blood model over a range of blood pressures. Eight patient-specific stenoses were also modeled and analyzed with CFD and the resulting blood flow calculations were validated by comparison with brachial artery flow measured by duplex ultrasound. Results Predicted flow rates were derived from CFD analysis of a range of stenoses. These stenoses were modeled by CFD and correlated with the ultrasound measured flow rate through the fistula of eight patients. The calculated flow rate using CFD correlated within 20% of ultrasound measured flow for five of eight patients. The mean difference was 17.2% (ranged from 1.3% to 30.1%). Conclusions CFD analysis-generated flow rate tables provide valuable information to assess the functional significance of stenosis detected during imaging studies. The CFD study can help in determining the clinical relevance of a stenosis in access dysfunction and guide the need for intervention.
Collapse
|
16
|
Arteriovenous access for Hemodialysis: Preoperative Assessment and Planning. J Vasc Access 2014; 15 Suppl 7:S1-5. [DOI: 10.5301/jva.5000255] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/08/2014] [Indexed: 11/20/2022] Open
Abstract
Longevity in end-stage renal disease (ESRD) is dependent on adequacy of renal replacement therapy. Over 85% of the global ESRD population is hemodialysis dependent. Preoperative evaluation is the cornerstone of vascular access planning. The goal of preoperative evaluation is to design a sequence of options that can be used to provide vascular access throughout the life span of an ESRD patient. The intention should be to provide a durable vascular access in a timely fashion that needs few interventions, while refraining from jeopardizing future needs.
Collapse
|
17
|
Ricci S, Cinthio M, Ahlgren AR, Tortoli P. Accuracy and reproducibility of a novel dynamic volume flow measurement method. ULTRASOUND IN MEDICINE & BIOLOGY 2013; 39:1903-1914. [PMID: 23849385 DOI: 10.1016/j.ultrasmedbio.2013.04.017] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/12/2012] [Revised: 03/11/2013] [Accepted: 04/21/2013] [Indexed: 06/02/2023]
Abstract
In clinical practice, blood volume flow (BVF) is typically calculated assuming a perfect parabolic and axisymmetric velocity distribution. This simple approach cannot account for the complex flow configurations that are produced by vessel curvatures, pulsatility and diameter changes and, therefore, results in a poor estimation. Application of the Womersley model allows compensation for the flow distortion caused by pulsatility and, with some adjustment, the effects of slight curvatures, but several problems remain unanswered. Two- and three-dimensional approaches can acquire the actual velocity field over the whole vessel section, but are typically affected by a limited temporal resolution. The multigate technique allows acquisition of the actual velocity profile over a line intersecting the vessel lumen and, when coupled with a suitable wall-tracking method, can offer the ideal trade-off among attainable accuracy, temporal resolution and required calculation power. In this article, we describe a BVF measurement method based on the multigate spectral Doppler and a B-mode edge detector algorithm for wall-position tracking. The method has been extensively tested on the research platform ULA-OP, with more than 1700 phantom measurements at flow rates between 60 and 750 mL/min, steering angles between 10 ° and 22 ° and constant, sinusoidal or pulsed flow trends. In the averaged BVF measurement, we found an underestimation of about -5% and a coefficient of variability (CV) less than 6%. In instantaneous measurements (e.g., systolic peak) the CV was in the range 2%-8.5%. These results were confirmed by a preliminary test on the common carotid artery of 10 volunteers (CV = 2%-11%).
Collapse
Affiliation(s)
- Stefano Ricci
- Information Engineering Department, University of Florence, Florence, Italy.
| | | | | | | |
Collapse
|