1
|
Hinterstein S, Ehrhardt H, Zimmer KP, Windhorst AC, Kappesser J, Hermann C, Schuler R, Waitz M. Skin Transillumination Improves Peripheral Vein Cannulation by Residents in Neonates: A Randomized Controlled Trial. Neonatology 2024:1-9. [PMID: 38754396 DOI: 10.1159/000538880] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/03/2024] [Accepted: 04/10/2024] [Indexed: 05/18/2024]
Abstract
INTRODUCTION Establishing peripheral vein access is challenging for pediatric residents and a painful procedure for neonates. We assessed the efficacy of a red light-emitting diode transilluminator during peripheral vein catheter insertion performed by pediatric residents. METHODS Patients were stratified by current weight (≤1,500 g, >1,500 g) and randomized to the transillumination or the control group. The first three attempts were performed by pediatric residents, followed by three attempts by a neonatologist. The primary outcome was success at first attempt. Secondary comparisons included time to successful insertion and overall success rates of residents and neonatologists. RESULTS A total of 559 procedures were analyzed. The success rate at resident's first attempt was 44/93 (47%) with transillumination versus 44/90 (49%) without transillumination (p = 0.88) in the strata ≤1,500 g and 103/188 (55%) with transillumination versus 64/188 (34%) without transillumination in the strata >1,500 g (p < 0.001). The overall success rate for residents was 86% in the transillumination versus 73% in the control group in the strata >1,500 g (p = 0.003) but not different in the strata ≤1,500 g (78/93 [84%] vs. 72/90 [80%], p = 0.57). There was no effect when the experience level of residents exceeded 6 months. Neonatologists' overall success rate and time to successful cannulation did not differ significantly in both weight strata. CONCLUSION Transillumination improves the first-attempt success rate of peripheral vein cannulation performed by pediatric residents in neonates >1,500 g, while no benefit was found in infants ≤1,500 g.
Collapse
Affiliation(s)
- Samantha Hinterstein
- Department of General Pediatrics and Neonatology, Center for Pediatrics and Youth Medicine, Justus-Liebig-University of Giessen, Giessen, Germany
| | - Harald Ehrhardt
- Department of General Pediatrics and Neonatology, Center for Pediatrics and Youth Medicine, Justus-Liebig-University of Giessen, Giessen, Germany
| | - Klaus-Peter Zimmer
- Department of General Pediatrics and Neonatology, Center for Pediatrics and Youth Medicine, Justus-Liebig-University of Giessen, Giessen, Germany
| | | | - Judith Kappesser
- Department of Psychology, Justus-Liebig-University of Giessen, Giessen, Germany
| | - Christiane Hermann
- Department of Psychology, Justus-Liebig-University of Giessen, Giessen, Germany
| | - Rahel Schuler
- Department of General Pediatrics and Neonatology, Center for Pediatrics and Youth Medicine, Justus-Liebig-University of Giessen, Giessen, Germany
| | - Markus Waitz
- Department of General Pediatrics and Neonatology, Center for Pediatrics and Youth Medicine, Justus-Liebig-University of Giessen, Giessen, Germany
| |
Collapse
|
2
|
Sykes S, Ulloa J, Steward D. Midline Catheter Use in the Neonatal Intensive Care Unit. Crit Care Nurs Clin North Am 2024; 36:111-118. [PMID: 38296369 DOI: 10.1016/j.cnc.2023.09.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2024]
Abstract
Neonates admitted to the neonatal intensive care unit (NICU) are a unique population who most often begin life acutely or critically ill. Venous access is required by most acutely/critically ill neonates, especially those born preterm. Access is required for implementing management strategies such as stabilization, medications, fluids, nutrition, and transfusion of blood products. However, achieving and maintaining venous access in these neonates can be difficult, especially in preterm infants due to a myriad of contributing factors. Peripheral intravenous (PIV) catheters and peripherally inserted central catheters (PICC) are 2 common vascular access approaches used in the NICU and have traditionally been the most studied in the neonatal literature. Both options offer advantages and disadvantages. An alternative to PIVs and PICCs is the midline peripheral catheter (MPC), which in the literature may also be referred to as extended dwell peripheral intravenous catheters. Depending on the intended use, the MPC offers a venous access approach between a PIV and PICC. Usage of MPCs in the NICU is slowly increasing with the limited published evidence suggesting they are viable option when considering the need for vascular access. The purpose of this article is to present the advantages and disadvantages of MPCs as an alternative approach for venous access in neonates when appropriate.
Collapse
Affiliation(s)
- Stephanie Sykes
- The Ohio State University College of Nursing, 295 West 10th Avenue, Columbus, OH 43210, USA.
| | - Jodi Ulloa
- The Ohio State University College of Nursing, 295 West 10th Avenue, Columbus, OH 43210, USA
| | - Deborah Steward
- The Ohio State University College of Nursing, 295 West 10th Avenue, Columbus, OH 43210, USA
| |
Collapse
|
3
|
Rommelfanger E, Lee E, Sauer C. Administering Intravenous Fluid in the Immediate Postpartum Period Minimizes Ultimate Formula Feeding. Breastfeed Med 2024; 19:109-113. [PMID: 38265433 DOI: 10.1089/bfm.2023.0171] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/25/2024]
Abstract
Background: Human milk is the optimal form of nutrition for infants. Interventions associated with a decreased rate of exposure to infant formula are of benefit. We hypothesized that intravenous (IV) fluids could be associated with a reduction of infant formula when infants are separated from their mother. Methods: Retrospective chart review of term infants admitted to Rady Children's Neonatal Intensive Care Units (NICUs) for possible sepsis who received antibiotic treatment but did not develop sepsis. IV fluid use and formula exposure were analyzed. Results: Six hundred twenty-eight infants met the inclusion criteria. Around 25.6% received IV fluids and 74.4% did not. IV fluid administration was associated with a significantly reduced chance of formula exposure while in the NICU (odds ratio: 0.694, 95% confidence interval: 0.484-0.993; *p = 0.046). Conclusion: This retrospective chart review found that infants transferred to the NICU and separated from their mothers due to chorioamnionitis exposure who received IV fluids were significantly less likely to receive any infant formula than infants who were not administered IV fluids.
Collapse
Affiliation(s)
- Emma Rommelfanger
- University of California San Diego School of Medicine, La Jolla, California, USA
| | - Euyhyun Lee
- Altman Clinical and Translational Research Institute, University of California School of Medicine, La Jolla, California, USA
| | - Charles Sauer
- Division of Neonatology, University of California San Diego and Rady Children's Hospital San Diego, San Diego, California, USA
| |
Collapse
|
4
|
D'Andrea V, Prontera G, Pezza L, Barone G, Vento G, Pittiruti M. Rapid Superficial Vein Assessment (RaSuVA): A pre-procedural systematic evaluation of superficial veins to optimize venous catheterization in neonates. J Vasc Access 2024; 25:303-307. [PMID: 35593484 DOI: 10.1177/11297298221098481] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
BACKGROUND Placement of peripheral intra-venous cannulas and epicutaneo-caval catheters is routinely performed in in Neonatal Intensive Care Unit (NICU), and both devices require visible superficial veins easy to cannulate. NICU patients are intrinsically characterized by poor and fragile vein asset, so that puncture and cannulation of superficial veins is often a challenge even for trained clinicians and cannulation frequently results in a stressful, painful, difficult procedure. METHODS AND RESULTS Rapid Superficial Vein Assessment is meant to offer a systematic pre-procedural evaluation of all superficial veins of the newborn, so to allow a rational choice of the best insertion site, tailored on the single patient, and optimized for the specific type of venous access device. The superficial veins are examined systematically, both with and without NIR technology, exploring seven skin areas in the following order: (1) medial malleolus, (2) lateral malleolus, (3) retro-popliteal fossa, (4) back of the hand and wrist, (5) antecubital fossa, (6) anterior scalp surface, and (7) posterior scalp surface. CONCLUSIONS The aim of the protocol is to increase the first attempt success rate and reduce the duration of the procedure, the number of attempts for single patient and possibly to limit complications, stress, and pain in neonates.
Collapse
Affiliation(s)
- Vito D'Andrea
- Department of Woman and Child Health and Public Health, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
| | - Giorgia Prontera
- Department of Woman and Child Health and Public Health, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
| | - Lucilla Pezza
- Department of Woman and Child Health and Public Health, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
| | - Giovanni Barone
- Neonatal Intensive Care Unit, Infermi Hospital, Rimini, Italy
| | - Giovanni Vento
- Department of Woman and Child Health and Public Health, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
| | - Mauro Pittiruti
- Department of Surgery, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
| |
Collapse
|
5
|
Indarwati F, Munday J, Keogh S. Peripheral intravenous catheter insertion, maintenance and outcomes in Indonesian paediatric hospital settings: A point prevalence study. J Pediatr Nurs 2023; 73:106-112. [PMID: 37659338 DOI: 10.1016/j.pedn.2023.08.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Revised: 08/09/2023] [Accepted: 08/09/2023] [Indexed: 09/04/2023]
Abstract
PURPOSE This study aimed to assess peripheral intravenous catheter use, maintenance practices, and outcomes of paediatric patients in a developing country setting. DESIGN AND METHODS A point prevalence survey using validated checklist was conducted between March and April 2022 in ten hospitals in Indonesia. A total number of 478 participants were approached during the audit. Data were obtained from site observation and medical records. RESULTS Of the 386 patients surveyed, >90% (362) had one catheter in-situ. The catheters were mostly inserted by nurses (331, 86%), primarily in the dorsum of the hand (207, 54%) with the purpose of delivering intravenous infusions and medications (367, 95%). Simple transparent dressings (176, 46%) with splint and bandage (295, 76%) were predominantly used for securement methods. Insertion sites were not visible for 182 (47%) patients, and 151 (40%) of daily care practices were poorly documented. Complications were documented in the medical record for 166 (43%) catheters. Adjusted analysis indicated that patient diagnosis, ward, catheter size, location, dressings, infusate, and flushing administration were significantly associated with complications. CONCLUSIONS Findings indicate that issues related to paediatric intravenous catheter complications in Indonesia are comparable to developed country settings. Ongoing surveillance is important to evaluate the management practices to benchmark against guidelines, optimise patient safety, and improve outcomes. PRACTICE IMPLICATIONS Results demonstrate low and middle-income countries face similar challenges with catheter insertion and care. The study indicates the importance of applying vascular access needs assessments, providing training for inserters, identifying optimum dressing methods, and optimising documentation.
Collapse
Affiliation(s)
- Ferika Indarwati
- Queensland University of Technology (QUT), School of Nursing and Centre for Healthcare Transformation, Brisbane, Queensland, Australia; School of Nursing, Faculty of Medicine and Health Sciences, Universitas Muhammadiyah Yogyakarta, Yogyakarta, Indonesia; Alliance of Vascular Access Teaching and Research Group, Griffith University, Queensland, Australia.
| | - Judy Munday
- Queensland University of Technology (QUT), School of Nursing and Centre for Healthcare Transformation, Brisbane, Queensland, Australia; Faculty of Health and Nursing Sciences, University of Agder, Grimstad, Norway.
| | - Samantha Keogh
- Queensland University of Technology (QUT), School of Nursing and Centre for Healthcare Transformation, Brisbane, Queensland, Australia; Nursing and Midwifery Research Centre, Royal Brisbane and Women's Hospital, Brisbane, Queensland, Australia; Alliance of Vascular Access Teaching and Research Group, Griffith University, Queensland, Australia.
| |
Collapse
|
6
|
van Rens MF, Hugill K, Mahmah MA, Francia AL, van Loon FH. Effect of peripheral intravenous catheter type and material on therapy failure in a neonatal population. J Vasc Access 2023; 24:1284-1292. [PMID: 35196909 DOI: 10.1177/11297298221080071] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
BACKGROUND In neonatal settings vascular access devices are essential for treatment. However, their use is not without risks. The design and materials of peripheral vascular access devices have been evaluated amongst adult populations, but contemporary studies in neonatal settings are scant. PURPOSE/OUTCOME MEASURES This research describes the prevalence of peripheral intravenous catheter failure related to three different catheter types with the intent to identify modifiable risks that might be used to evaluate device efficacy, innovate neonatal practice, and support future policy developments. METHOD AND SETTING This was a retrospective observational analysis of routinely collected anonymized intravenous therapy related data. The study was carried out at the tertiary neonatal intensive care unit (112 beds) of the Women's Wellness and Research Center of Hamad Medical Corporation, Doha, Qatar. PARTICIPANTS Neonates who were admitted to the unit requiring intravenous treatment wherefore peripheral intravenous cannulation was indicated, were included in this study. RESULTS The use of different type of catheters resulted in significantly less therapy failures as phlebitis and increased dwell time, compared with the control groups. This remains significant after adjusting for age at insertion, gestational age, birth weight, and catheter type. CONCLUSIONS The study's findings are in accord with international literature concerning adult and pediatric patients concerning the superiority of PUR over PTFE catheters with respect to the risk of phlebitis and longer dwell times. However, the risk of failure of therapy did not differ between catheters. This finding is reassuring and supports practitioner judgment when selecting peripheral catheter devices.
Collapse
Affiliation(s)
- Matheus Fpt van Rens
- Neonatal Intensive Care Unit, Women's Wellness and Research Center, Hamad Medical Corporation, Doha, Qatar
| | | | - Mohamad Adnan Mahmah
- Neonatal Intensive Care Unit, Women's Wellness and Research Center, Hamad Medical Corporation, Doha, Qatar
| | - Airene Lv Francia
- Neonatal Intensive Care Unit, Women's Wellness and Research Center, Hamad Medical Corporation, Doha, Qatar
| | - Fredericus Hj van Loon
- Department of Anesthesiology, Intensive Care and Pain Medicine, Catharina Hospital, Eindhoven, The Netherlands
- Department of Perioperative Care and Technology, Fontys University of Applied Sciences, Eindhoven, The Netherlands
| |
Collapse
|
7
|
Vadapalli S, Valvi C, Nagpal RS, Dawre RM, Kinikar AA. Improving the longevity of intravenous cannulas in sick neonates admitted to NICU in a tertiary care centre: a quality improvement project. BMJ Open Qual 2023; 12:e002372. [PMID: 37984891 PMCID: PMC10660628 DOI: 10.1136/bmjoq-2023-002372] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2023] [Accepted: 10/26/2023] [Indexed: 11/22/2023] Open
Abstract
BACKGROUND Neonatal intravenous cannulation, especially in preterms, is more challenging than in children or adults. Placement of an intravenous cannula is painful and many cannulas need frequent changing due to complications. Each attempt at cannulation creates an entry for skin flora to cause systemic bacteraemia. This study was undertaken at a level III NICU. The team attempted to prolong the existing cannula longevity to reduce the frequency of intravenous cannulation thereby reducing handling and pain. OBJECTIVES To improve the longevity of peripherally inserted intravenous cannula in sick neonates in NICU from the current 25.7 hours to 36 hours or more, over a span of 6 weeks. MATERIALS AND METHODS The quality improvement (QI) team comprised resident doctors and staff nurses. A fishbone analysis was used to identify factors that affected the longevity of intravenous cannulas. Five WHYs technique was used to identify the cause behind early cannula removal. Both techniques identified the fixation technique used at the study centre for target intervention. Plan-Do-Study-Act cycles were planned to explore different fixation techniques to improve cannula longevity. The unpaired t-test and the χ2 tests were applied to analyse statistical significance. RESULTS We achieved significant improvement in cannula longevity from 25.7 hours to 39.6 hours just by improving the fixation technique over 6 weeks with a p=0.0006. CONCLUSIONS The QI study was successful and is adopted for routine practice. Such initiatives would greatly impact babies in low-resource settings and in transit.
Collapse
Affiliation(s)
- Sailusha Vadapalli
- Peadiatrics, Byramjee Jeejeebhoy Government Medical College and Sassoon General Hospitals, Pune, Maharashtra, India
| | - Chhaya Valvi
- Pediatrics, Grant Medical College and Sir JJ Group of Hospitals, Mumbai, Maharashtra, India
| | - Rema S Nagpal
- Peadiatrics, Byramjee Jeejeebhoy Government Medical College and Sassoon General Hospitals, Pune, Maharashtra, India
| | - Rahul M Dawre
- Paediatrics, Byramjee Jeejeebhoy Government Medical College and Sassoon General Hospitals, Pune, Maharashtra, India
| | - Aarti A Kinikar
- Paediatrics, Byramjee Jeejeebhoy Government Medical College and Sassoon General Hospitals, Pune, Maharashtra, India
| |
Collapse
|
8
|
McIntyre C, August D, Cobbald L, Lack G, Takashima M, Foxcroft K, Marsh N, Smith P, New K, Koorts P, Irwin A, Ullman A. Neonatal Vascular Access Practice and Complications: An Observational Study of 1,375 Catheter Days. J Perinat Neonatal Nurs 2023; 37:332-339. [PMID: 37878518 DOI: 10.1097/jpn.0000000000000589] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Vascular access devices play vital roles within neonatal care. We aimed to identify neonatal vascular access device insertion and management practices, and describe the incidence and risk factors for complication development. This is a prospective cohort study of neonates requiring vascular access devices over 3 months in an Australian quaternary-referral neonatal intensive care unit. In addition to describing current practices, primary outcomes were device failure, complications, and skin complications. Results are reported using descriptive statistics and with risk factors calculated via Cox proportional hazards regression. A total of 104 neonates required 302 vascular access devices, over 1375 catheter days. Peripheral intravenous catheters (PIVCs) were most used (n = 186; 62%), followed by umbilical venous catheters (n = 52; 17%). Insertion attempts were often undocumented; but for those recorded, 5% of devices (n = 15) required 4 attempts or more. Device failure occurred in 28% (n = 82), at an incidence rate of 62.5 per 1000 catheter days (95% confidence interval [CI] 49.7-75.9). Failure was most frequent in PIVCs (37%; n = 68), peripheral arterial catheters (33%; n = 2), and peripherally inserted central catheters (20%; n = 6). Infiltration and extravasation were the most frequent cause of PIVC failure (12%; n = 35). A birth weight less than 1500 g was associated with a significant decrease in PIVC failure (hazard ratio 0.58; 95% CI 0.34-0.99).
Collapse
Affiliation(s)
- Colette McIntyre
- Women's and Newborns Service, Royal Brisbane and Women's Hospital, Herston, Queensland, Australia (Mss McIntyre, August, Cobbald, Lack, Foxcroft, and Smith and Mr Koorts); Alliance for Vascular Access Teaching and Research (AVATAR), Menzies Health Institute Queensland, Griffith University, Nathan, Queensland, Australia (Mss August and Takashima and Dr Ullman); School of Nursing and Midwifery, Griffith University, Nathan, Queensland, Australia (Ms August and Dr Ullman); UQ Centre for Clinical Research, Faculty of Medicine, The University of Queensland, Herston, Queensland, Australia (Ms Foxcroft); Nursing and Midwifery Centre for Research, Royal Brisbane and Women's Hospital, Herston, Queensland, Australia (Drs Marsh, New, and Ullman); School of Nursing, Midwifery and Social Work, University of Queensland, St Lucia, Queensland, Australia (Drs Marsh, New, and Ullman); Children's Health Queensland and the University of Queensland, Brisbane, Queensland, Australia (Drs Irwin and Ullman); and School of Nursing, Queensland University of Technology, Kelvin Grove, Australia (Dr Marsh)
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
9
|
Romitti MG, Perez CR, Pezzotti E, Motta M, Risso FM. Long peripheral catheters in neonates: filling the gap between short peripheral catheters and epicutaneous-caval catheters? J Vasc Access 2023; 24:920-925. [PMID: 34789024 DOI: 10.1177/11297298211057377] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
INTRODUCTION Non-critically ill neonates at times require venous access to provide peripherally compatible infusions for a limited period (more than 3 days). In such a situation, short peripheral cannulas are not appropriate as their average duration is about 2 days, while-on the other hand-epicutaneous-caval catheters may be too invasive. In these patients, insertion of long peripheral cannulas may be an effective option. METHODS In this observational retrospective study, we revised all "long" peripheral catheters (4 and 6 cm long) inserted by direct Seldinger technique in our neonatal intensive care unit when peripheral venous access was required for more than 3 days. RESULTS We inserted 52 2Fr polyurethane catheters, either 4 cm long (n = 25) or 6 cm long (n = 27) in 52 patients. Mean dwelling time was 4.17 days (range 1-12). Most devices were inserted in the cephalic vein (n = 18, 35%), and the rest in the saphenous vein (n = 11, 21%) and other superficial veins. There was no significant correlation between the duration of the device and type of infusion (p = 0.40). The main complications were infiltration (n = 16, 31%) and phlebitis (n = 8, 15%). The rate of removal due to complications was significantly higher (p < 0.01) in neonates with bodyweight <2000 g at the time of insertion. CONCLUSION In our experience, 2 Fr 4-6 cm long peripheral catheters may be a valid option for neonates requiring peripherally compatible infusions for more than 3 days. The limits of this study are the necessity of training in the technique of insertion and the small size of our sample. The longest dwell was observed in neonates weighing >2000 g at the time of LPC insertion.
Collapse
Affiliation(s)
- Maria Grazia Romitti
- Neonatal Intensive Care Unit, Children's Hospital, ASST Spedali Civili di Brescia, Brescia, Italy
| | - Carmen Rodriguez Perez
- Neonatal Intensive Care Unit, Children's Hospital, ASST Spedali Civili di Brescia, Brescia, Italy
| | - Elena Pezzotti
- Neonatal Intensive Care Unit, Children's Hospital, ASST Spedali Civili di Brescia, Brescia, Italy
| | - Mario Motta
- Neonatal Intensive Care Unit, Children's Hospital, ASST Spedali Civili di Brescia, Brescia, Italy
| | - Francesco Maria Risso
- Neonatal Intensive Care Unit, Children's Hospital, ASST Spedali Civili di Brescia, Brescia, Italy
| |
Collapse
|
10
|
Thushara NL, Singh P, Priyadarshi M, Chaurasia S, Bhat NK, Basu S. Functional Duration of Peripheral Intravenous Cannula in Neonates with or without Splint: A Randomized Controlled Trial. Indian J Pediatr 2023:10.1007/s12098-023-04756-w. [PMID: 37578610 DOI: 10.1007/s12098-023-04756-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/01/2023] [Accepted: 06/26/2023] [Indexed: 08/15/2023]
Abstract
OBJECTIVES To determine the effect of splint on the functional duration of peripheral intravenous cannula (PIVC) in neonates. METHODS The trial was prospectively registered with the Clinical Trial Registry of India (CTRI/2021/09/036337). One-hundred-fifty cannulations in 71 neonates were randomized to splint (n = 75) and no-splint (n = 75) groups, respectively. The median (interquartile range, IQR) functional duration of PIVC was calculated from the time of PIVC insertion till removal due to the development of signs of PIVC failure or treatment completion. Kaplan-Meier survival analysis was used to compute the time to complication of PIVC. Complications related to PIVC were noted and multivariate Cox-proportion hazard analysis was done to find the predictors associated with PIVC failure. RESULTS Median (IQR) functional duration of PIVC in the splint and the no-splint group was 28 (23-48) and 30 (25-48) h, respectively (p = 0.477). PIVC duration was higher in the splint group in term neonates and the no-splint group in preterm neonates; however, the differences were not statistically significant. No difference was observed in continuous vs. intermittent infusion subgroups. Time to complication development was also comparable between the groups. CONCLUSIONS Splint application did not affect functional PIVC duration and its related complications in neonates.
Collapse
Affiliation(s)
- Nadella Lakshmi Thushara
- Department of Neonatology, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, 249203, India
- Department of Pediatrics, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, India
| | - Poonam Singh
- Department of Neonatology, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, 249203, India.
| | - Mayank Priyadarshi
- Department of Neonatology, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, 249203, India
| | - Suman Chaurasia
- Department of Neonatology, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, 249203, India
| | - Nowneet Kumar Bhat
- Department of Pediatrics, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, India
| | - Sriparna Basu
- Department of Neonatology, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, 249203, India
| |
Collapse
|
11
|
Barone G, D'Andrea V, Ancora G, Cresi F, Maggio L, Capasso A, Mastroianni R, Pozzi N, Rodriguez-Perez C, Romitti MG, Tota F, Spagnuolo F, Raimondi F, Pittiruti M. The neonatal DAV-expert algorithm: a GAVeCeLT/GAVePed consensus for the choice of the most appropriate venous access in newborns. Eur J Pediatr 2023; 182:3385-3395. [PMID: 37195350 DOI: 10.1007/s00431-023-04984-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Revised: 04/11/2023] [Accepted: 04/15/2023] [Indexed: 05/18/2023]
Abstract
In most NICUs, the choice of the venous access device currently relies upon the operator's experience and preferences. However, considering the high failure rate of vascular devices in the neonatal population, such clinical choice has a critical relevance and should preferably be based on the best available evidence. Though some algorithms have been published over the last 5 years, none of them seems in line with the current scientific evidence. Thus, the GAVePed-which is the pediatric interest group of the most important Italian group on venous access, GAVeCeLT-has developed a national consensus about the choice of the venous access device in the neonatal population. After a systematic review of the available evidence, the panel of the consensus (which included Italian neonatologists specifically experts in this area) has provided structured recommendations answering four sets of questions regarding (1) umbilical venous catheters, (2) peripheral cannulas, (3) epicutaneo-cava catheters, and (4) ultrasound-guided centrally and femorally inserted central catheters. Only statements reaching a complete agreement were included in the final recommendations. All recommendations were also structured as a simple visual algorithm, so as to be easily translated into clinical practice. Conclusion: The goal of the present consensus is to offer a systematic set of recommendations on the choice of the most appropriate vascular access device in Neonatal Intensive Care Unit.
Collapse
Affiliation(s)
- Giovanni Barone
- Neonatal Intensive Care Unit, Infermi Hospital, AUSL Della Romagna, Viale Settembrini 2, Rimini, Italy.
| | - Vito D'Andrea
- Neonatal Intensive Care Unit, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
| | - Gina Ancora
- Neonatal Intensive Care Unit, Infermi Hospital, AUSL Della Romagna, Viale Settembrini 2, Rimini, Italy
| | - Francesco Cresi
- Neonatology and Neonatal Intensive Care Unit, Sant'Anna Hospital, University of Turin, Città Della Salute E Della Scienza, Turin, Italy
| | - Luca Maggio
- Neonatology and Neonatal Intensive Care Unit, AO San Camillo Forlanini, Rome, Italy
| | - Antonella Capasso
- Neonatology and Neonatal Intensive Care Unit, A.O.U. Federico 2, Naples, Italy
| | | | - Nicola Pozzi
- Neonatal Intensive Care Unit, San Pio Hospital, Benevento, Italy
| | - Carmen Rodriguez-Perez
- Neonatology and Neonatal Intensive Care Unit, ASST Spedali Civili, Ospedale Dei Bambini, Brescia, Italy
| | | | - Francesca Tota
- Neonatal Intensive Care Unit, Ospedale S. Chiara, APSS, Trento, Italy
| | - Ferdinando Spagnuolo
- Neonatal Intensive Care Unit, AOU Università Degli Studi Della Campania "Luigi Vanvitelli", Naples, Italy
| | - Francesco Raimondi
- Neonatology and Neonatal Intensive Care Unit, A.O.U. Federico 2, Naples, Italy
| | - Mauro Pittiruti
- Department of Surgery, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
| |
Collapse
|
12
|
van Rens MF, Vijlbrief D, Braun S, Hugill K, van Loon FH, van de Hoogen A. Peripheral intravenous therapy infiltration/extravasation (PIVIE) risks and the potential for earlier notification of events using a novel sensor technology in a neonatal population. J Vasc Access 2023:11297298231185536. [PMID: 37395292 DOI: 10.1177/11297298231185536] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/04/2023] Open
Abstract
BACKGROUND Intravenous (IV) therapy using short peripheral IV catheters (PIVC) is commonplace with neonatal patients. However, this therapy is associated with high complication rates including the leakage of infused fluids from the vasculature into the surrounding tissues; a condition referred to as, peripheral IV infiltration/extravasation (PIVIE). OBJECTIVE The quality improvement project aimed to identify the prevalence of known risk factors for PIVIE in the neonatal intensive care unit (NICU) and explore the feasibility of using novel optical sensor technology to aid in earlier detection of PIVIE events. METHODS The plan, do, study, act (PDSA) model of quality improvement (QI) was used to provide a systematic framework to identify PIVIE risks and evaluate the potential utility of continuous PIVC monitoring using the ivWatch model 400® system. The site was provided with eight monitoring systems and consumables. Hospital staff were supported with theoretical education and bedside training about the system operations and best use practices. RESULTS In total 113 PIVIE's (graded II-IV) were recorded from 3476 PIVCs, representing an incidence of 3.25%. Lower birth weight and gestational age were statistically significant factors for increased risk of PIVIE (p = 0.004); all other known risk factors did not reach statistical significance. Piloting the ivWatch with 21 PIVCs using high-risk vesicant solutions over a total of 523.9 h (21.83 days) detected 11 PIVIEs (graded I-II). System sensitivity reached 100%; 11 out of 11 PIVIEs were detected by the ivWatch before clinician confirmation. CONCLUSIONS Prevailing risk factors for PIVIE in the unit were comparable to those published. Continuous infusion site monitoring using the ivWatch suggests this technology offers the potential to detect PIVIE events earlier than relying on intermittent observation alone (i.e. the current standard of care). However, large-scale study with neonatal populations is required to ensure the technology is optimally configured to meet their needs.
Collapse
Affiliation(s)
| | - Daniel Vijlbrief
- Department of Neonatology, Wilhelmina Children's Hospital, UMC Utrecht, Utrecht, The Netherlands
| | - Sophie Braun
- Department of Neonatology, Wilhelmina Children's Hospital, UMC Utrecht, Utrecht, The Netherlands
| | | | - Fredericus Hj van Loon
- Department of Perioperative Care and Technology, Fontys University of Applied Sciences, Eindhoven, The Netherlands
- Department of Anesthesiology, Intensive Care and Pain Medicine, Catharina Hospital, Eindhoven, The Netherlands
| | - Agnes van de Hoogen
- Department of Neonatology, Wilhelmina Children's Hospital, UMC Utrecht, Utrecht, The Netherlands
- Clinical Health Science at Utrecht University (UU), Utrecht, The Netherlands
| |
Collapse
|
13
|
Gunasagaran J, Ong TCC, Devarajooh C, Ahmad TS. The Outcome of Moderate-to-Severe Complications Related to Peripheral Intravenous Devices at Upper Limb. J Hand Surg Asian Pac Vol 2023; 28:235-240. [PMID: 37120295 DOI: 10.1142/s2424835523500273] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/01/2023]
Abstract
Background: Intravenous access is very crucial in administration of fluids, medications and nutrition. Almost all inpatients will require it and the simplest and quickest access is peripheral with the preferred sites being either dorsum hand, radial wrist or forearm. It has its complications, of which most are avoidable. Literature has emphasised the complications and reported on preventive measures but lacks the sequelae of the complications related to peripheral intravenous devices (PIVD). We report on the sequelae of moderate-to-severe complications of these patients. Methods: Thirty-three patients had moderate-to-severe complications related to PIVD in a tertiary centre from January 2017 to December 2017. All data were obtained from electronic medical report (EMR). Results: Majority had extravasation (45.5%) and abscess (39.4%), whereas two patients had thrombophlebitis (6.1%) and three patients developed necrotising fasciitis (9.1%). All patients with abscess and necrotising fasciitis underwent surgical intervention (n = 16); four patients had multiple debridements. All infections were treated with empirical antibiotics and changed after culture results were obtained. Seven patients had sepsis/bacteraemia wherein two of them passed away. A total of 31 patients were discharged. Two patients had secondary suturing of the wound, one had split-thickness skin grafting (SSG) coverage and the others had daily dressing until the wound healed by secondary intention. Conclusions: PIVD-related complications can be debilitating and may occur despite strict preventive measures. Early clinical diagnosis and prompt treatment of these complications can decrease its morbidity. Level of Evidence: Level IV (Prognostic).
Collapse
Affiliation(s)
- Jayaletchumi Gunasagaran
- National Orthopaedic Centre of Excellence for Research and Learning (NOCERAL), Department of Orthopaedic Surgery, Faculty of Medicine, Universiti Malaya, Kuala Lumpur, Malaysia
| | | | - Cassidy Devarajooh
- Bentong District Health Office, Ministry of Health, Bentong, Pahang, Malaysia
| | - Tunku Sara Ahmad
- National Orthopaedic Centre of Excellence for Research and Learning (NOCERAL), Department of Orthopaedic Surgery, Faculty of Medicine, Universiti Malaya, Kuala Lumpur, Malaysia
| |
Collapse
|
14
|
van Rens MF, Spencer TR, Hugill K, Francia AL, van Loon FH, Bayoumi MA. Octyl-butyl-cyanoacrylate glue for securement of peripheral intravenous catheters: A retrospective, observational study in the neonatal population. J Vasc Access 2023:11297298231154629. [PMID: 36794683 DOI: 10.1177/11297298231154629] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/17/2023] Open
Abstract
BACKGROUND Evidence-based insertion and maintenance strategies for neonatal vascular access devices (VAD) exist to reduce the causes of VAD failure and complications in neonates. Peripheral intravenous catheter failure and complications including, infiltration, extravasation, phlebitis, dislodgement with/without removal, and infection are majorly influenced by catheter securement methods. METHODS A retrospective, observational study using routinely collected data on intravenous device use in a large neonatal intensive care unit in Qatar. A 6-month historical cohort was compared with a 6-month cohort after the introduction of an octyl-butyl-cyanoacrylate glue (CG). In the historical cohort, the catheter was secured using a semi-permeable transparent membrane dressing while in the CG cohort, CG was applied at the insertion site on initial insertion and after any dressing change. This was the only variable intervention between both groups. RESULTS A total of 8330 peripheral catheters were inserted. All catheters were inserted and monitored by members of the NeoVAT team. 4457 (53.5%) were secured with just a semi-permeable transparent dressing and 3873 (46.5%) secured a semi-permeable transparent dressing with the addition of CG. The odds ratio for premature failure after securement with CG was 0.59 (0.54-0.65) when compared to the catheters secured with a semi-permeable transparent dressing, which was statistically significant (p < 0.001). The correlation between the occurrence of a complication and the use of CG for device securement was significant (p < 0.001). CONCLUSIONS The risk of developing device-related phlebitis and premature device removal, increased significantly if CG was not used for adjunct catheter securement. In parallel with the currently published literature, this study's findings support the use of CG for vascular device securement. When device securement and stabilization concerns are most pertinent CG is a safe and effective adjunct to reducing therapy failures in the neonatal patient population.
Collapse
Affiliation(s)
| | | | - Kevin Hugill
- Department of Nursing and Midwifery Education, Hamad Medical Corporation, Doha, Qatar
| | - Airene Lv Francia
- Women's Wellness and Research Center, Hamad Medical Corporation, Doha, Qatar
| | - Fredericus Hj van Loon
- Anesthesiology, Intensive Care and Pain Medicine, Catharina Hospital, Eindhoven, The Netherlands.,PeriOperative Care & Technology, Fontys University of Applied Sciences, Eindhoven, The Netherlands
| | - Mohammad Aa Bayoumi
- Women's Wellness and Research Center, Hamad Medical Corporation, Doha, Qatar
| |
Collapse
|
15
|
Baye ND, Teshome AA, Ayenew AA, Amare TJ, Mulu AT, Abebe EC, Tiruneh GA, Ayele TM, Muche ZT, Teklemariam AB, Melese BD, Agidew MM, Seid MA. Incidence, time to occurrence and predictors of peripheral intravenous cannula-related complications among neonates and infants in Northwest Ethiopia: an institutional-based prospective study. BMC Nurs 2023; 22:11. [PMID: 36631864 PMCID: PMC9832806 DOI: 10.1186/s12912-022-01164-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Accepted: 12/26/2022] [Indexed: 01/13/2023] Open
Abstract
BACKGROUND Peripheral intravenous cannulas (PIVC) are venous access devices commonly used for the administration of intravenous fluids, drugs, blood products, and parenteral nutrition. Despite its frequent use, it has complications that can seriously threaten patient safety, prolong hospital stays, and increases medical care costs. PIVC complications are associated with increased morbidity and reinsertion attempts are painful and anxiety-provoking for children and their parents. Therefore, this study was aimed to assess the incidence, time to occurrence and identify predictors for PIVC complications among infants admitted to Debre Tabor Comprehensive Specialized Hospital (DTCSH), Northwest Ethiopia. METHODS AND SETTING An institutional-based prospective cohort study was conducted on 358 infants admitted to a neonatal intensive care unit and pediatric ward, DTCSH from January 1 to April 30, 2022. A systematic sampling technique was employed. RESULTS The incidence rate of PIVC complication was 11.6 per 1000 person-hours observation. PIVC complication was observed in 56.4% (202) of PIVCs, of which infiltration (42.1%) was the most common complication followed by phlebitis (29.7%). The median time to complication was 46 h. Anatomical insertion site (AHR = 2.85, 95%CI: 1.63-6.27), admission unit (AHR = 1.88, 95%CI: 1.07-4.02), sickness (AHR = 0.24, 95% CI: 1.31-4.66), medication type (AHR = 2.04, 95%CI: 1.13-3.66), blood transfusion (AHR = 0.79, 95%CI: 0.02-0.99), clinical experience (AHR = 0.52, CI:0.26-0.84), and flushing (AHR = 0.71, 95%CI: 0.34-0.98) were potential predictors of PIVC complication. CONCLUSION Knowing the predictor factors helps clinicians to provide effective care and to detect complications early.
Collapse
Affiliation(s)
- Nega Dagnew Baye
- grid.510430.3Department of Biomedical Sciences, College of Health Sciences, Debre Tabor University, Debre Tabor, Ethiopia
| | - Assefa Agegnehu Teshome
- grid.510430.3Department of Biomedical Sciences, College of Health Sciences, Debre Tabor University, Debre Tabor, Ethiopia
| | - Atalo Agimas Ayenew
- grid.510430.3Department of Biomedical Sciences, College of Health Sciences, Debre Tabor University, Debre Tabor, Ethiopia
| | - Tadeg Jemere Amare
- grid.510430.3Department of Biomedical Sciences, College of Health Sciences, Debre Tabor University, Debre Tabor, Ethiopia
| | - Anmut Tilahun Mulu
- grid.510430.3Department of Biomedical Sciences, College of Health Sciences, Debre Tabor University, Debre Tabor, Ethiopia
| | - Endeshaw Chekol Abebe
- grid.510430.3Department of Biomedical Sciences, College of Health Sciences, Debre Tabor University, Debre Tabor, Ethiopia
| | - Gebrehiwot Ayalew Tiruneh
- grid.510430.3Department of Clinical Midwifery, College of Health Sciences, Debre Tabor University, Debre Tabor, Ethiopia
| | - Teklie Mengie Ayele
- grid.510430.3Department of Pharmacy, College of Health Sciences, Debre Tabor University, Debre Tabor, Ethiopia
| | - Zelalem Tilahun Muche
- grid.510430.3Department of Biomedical Sciences, College of Health Sciences, Debre Tabor University, Debre Tabor, Ethiopia
| | - Awgichew Behaile Teklemariam
- grid.510430.3Department of Biomedical Sciences, College of Health Sciences, Debre Tabor University, Debre Tabor, Ethiopia
| | - Biruk Demissie Melese
- grid.510430.3Department of Environmental Health, College of Health Sciences, Debre Tabor University, Debre Tabor, Ethiopia
| | - Melaku Mekonnen Agidew
- grid.510430.3Department of Biomedical Sciences, College of Health Sciences, Debre Tabor University, Debre Tabor, Ethiopia
| | - Mohammed Abdu Seid
- grid.510430.3Department of Biomedical Sciences, College of Health Sciences, Debre Tabor University, Debre Tabor, Ethiopia
| |
Collapse
|
16
|
van Rens M, Hugill K, Gaffari MAK, Francia AV, Ramkumar T, Garcia KLP, van Loon FHJ. Outcomes of establishing a neonatal peripheral vascular access team. Arch Dis Child Fetal Neonatal Ed 2023; 108:88-89. [PMID: 34620683 DOI: 10.1136/archdischild-2021-322764] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 09/26/2021] [Indexed: 12/31/2022]
Affiliation(s)
- Matheus van Rens
- Neonatal Intensive Care Unit, Women's Wellness and Research Center, Hamad Medical Corporation, Doha, Qatar
| | - Kevin Hugill
- Nursing and Midwifery Education, Hamad Medical Corporation, Doha, Qatar
| | | | - Airene V Francia
- Neonatal Intensive Care Unit, Women's Wellness and Research Center, Hamad Medical Corporation, Doha, Qatar
| | - Thiruveni Ramkumar
- Neonatal Intensive Care Unit, Women's Wellness and Research Center, Hamad Medical Corporation, Doha, Qatar
| | - Krisha L P Garcia
- Neonatal Intensive Care Unit, Women's Wellness and Research Center, Hamad Medical Corporation, Doha, Qatar
| | - Fredericus H J van Loon
- Anaesthesiology and Intensive Care, Catharina Hospital, Eindhoven, North Brabant, The Netherlands
| |
Collapse
|
17
|
Tseng JH, Elaine Chen YF, Chang SP, Wang HC, Kuo YT. Factors affecting the patency and complications of peripheral intravenous catheters in newborns. Pediatr Neonatol 2022; 64:239-246. [PMID: 36396543 DOI: 10.1016/j.pedneo.2022.07.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/07/2022] [Revised: 06/19/2022] [Accepted: 07/07/2022] [Indexed: 11/07/2022] Open
Abstract
BACKGROUND Peripheral intravenous catheters (PICs) are necessary for medication, nutrient, and fluid administration in pediatric patients. However, PICs are uneasy to access and maintain in young infants. This study identified risk factors affecting the complications and patency of PICs. METHODS This retrospective cohort study included neonates and infants aged <4 months. All PICs inserted in the neonatal intensive care unit and intermediate care nursery were analyzed more than 5 months. The variables included gestational age, age and body weight at PIC insertion, insertion site, methods to maintain PIC patency (continuous intravenous drip [CIVD] versus intermittent flushing), fluid infusion rate and osmolarity, and ampicillin and cefotaxime concentrations. The effects of these variables on PIC complications and lifespan were assessed using binary logistic regression analysis and a general linear model, respectively. RESULTS In total, 315 PICs were analyzed. The mean indwelling time was 33.8 ± 21.5 h and complication rate was 82.2%. The most frequent complications were infiltration (55.9%) and leakage (22.2%). The infusion rate and method to maintain PICs significantly impacted PIC patency. A negative correlation was noted between the infusion rate and PIC patency, with the patency decreasing by 0.9 h (p = 0.047) on increasing the infusion rate by 1 mL/h. Notably, compared with intermittent flushing, CIVD using a hypertonic solution significantly decreased PIC patency by 14 h (p = 0.006). As the patients' age increased by a month, the complication risk decreased by 35% (p = 0.027). However, as the infusion rate increased by 1 mL/h, the complication risk increased by 17% (p = 0.018). CONCLUSIONS Intermittent flushing may be preferred over CIVD to preserve PIC patency. An increased infusion rate is correlated with decreased PIC patency and increased complications. For the peripheral administration of ampicillin, we recommended preparing final concentrations below 50 mg/dL to prevent PIC complications.
Collapse
Affiliation(s)
- Ju-Huei Tseng
- Department of Pharmacy, Shuang Ho Hospital, Taipei Medical University, Taipei, Taiwan; School of Pharmacy, College of Pharmacy, Taipei Medical University, Taipei, Taiwan.
| | - Ying-Fang Elaine Chen
- Department of Pediatrics, Shuang Ho Hospital, Taipei Medical University, Taipei, Taiwan.
| | - Sun-Peng Chang
- Department of Nursing, Shuang Ho Hospital, Taipei Medical University, Taipei, Taiwan.
| | - Hsiao-Chin Wang
- Department of Pediatrics, Shuang Ho Hospital, Taipei Medical University, Taipei, Taiwan.
| | - Yung-Ting Kuo
- Department of Pediatrics, Shuang Ho Hospital, Taipei Medical University, Taipei, Taiwan; Department of Pediatrics, School of Medicine, College of Medicine, Taipei Medical University, Taipei, Taiwan.
| |
Collapse
|
18
|
Dufficy M, Takashima M, Cunninghame J, Griffin BR, McBride CA, August D, Ullman AJ. Extravasation injury management for neonates and children: A systematic review and aggregated case series. J Hosp Med 2022; 17:832-842. [PMID: 36039964 PMCID: PMC9804918 DOI: 10.1002/jhm.12951] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/27/2022] [Revised: 08/07/2022] [Accepted: 08/09/2022] [Indexed: 01/09/2023]
Abstract
BACKGROUND Pediatric extravasation injuries are significant healthcare-associated injuries, with sometimes significant sequelae. Evidence-based guidance on management is necessary to prevent permanent injury. PURPOSE A systematic review of the literature, including aggregated case series, investigating extravasation injury management of hospitalized pediatric patients. DATA SOURCES PubMed, Cummulative Index to Nursing and Allied Health Literature (CINAHL), and Excerpta Medica database (EMBASE) were searched on December 13, 2021. STUDY SELECTION Primary research investigating extravasation injury management of hospitalized pediatric patients (to 18 years), published from 2010 onwards and in English, independently screened by two authors, with arbitration from a third author. DATA EXTRACTION Data regarding the study, patient (age, primary diagnosis), extravasation (site, presentation, outcome), and treatment (first aid, wound management) were extracted by two authors, with arbitration from a third author. DATA SYNTHESIS From an initial 1769 articles, 27 studies were included with extractable case data reported in 18 studies, resulting in 33 cases. No clinical trials were identified, instead, studies were primarily case studies (52%) of neonates (67%), with varied extravasation symptoms. Studies had good selection and ascertainment, but few met the causality and reporting requirements for quality assessments. Signs and symptoms varied, with scarring (45%) and necrosis (30%) commonly described. Diverse treatments were categorized into first aid, medical, surgical, and dressings. CONCLUSIONS Despite infiltration and extravasation injuries being common within pediatric healthcare, management interventions are under-researched, with low-quality studies and no consensus on treatments or outcomes.
Collapse
Affiliation(s)
- Mitchell Dufficy
- School of Nursing, Midwifery and Social WorkThe University of QueenslandBrisbaneQueenslandAustralia
- Centre for Children's Health ResearchChildren's Health Queensland Hospital and Health ServiceBrisbaneQueenslandAustralia
| | - Mari Takashima
- School of Nursing, Midwifery and Social WorkThe University of QueenslandBrisbaneQueenslandAustralia
- Centre for Children's Health ResearchChildren's Health Queensland Hospital and Health ServiceBrisbaneQueenslandAustralia
| | - Jacqueline Cunninghame
- School of Nursing, Midwifery and Social WorkThe University of QueenslandBrisbaneQueenslandAustralia
- Centre for Children's Health ResearchChildren's Health Queensland Hospital and Health ServiceBrisbaneQueenslandAustralia
| | - Bronwyn R. Griffin
- Centre for Children's Health ResearchChildren's Health Queensland Hospital and Health ServiceBrisbaneQueenslandAustralia
- School of Nursing and MidwiferyGriffith UniversityBrisbaneQueenslandAustralia
| | - Craig A. McBride
- School of Nursing, Midwifery and Social WorkThe University of QueenslandBrisbaneQueenslandAustralia
- Centre for Children's Health ResearchChildren's Health Queensland Hospital and Health ServiceBrisbaneQueenslandAustralia
| | - Deanne August
- School of Nursing, Midwifery and Social WorkThe University of QueenslandBrisbaneQueenslandAustralia
- Centre for Children's Health ResearchChildren's Health Queensland Hospital and Health ServiceBrisbaneQueenslandAustralia
- Grantley Stable Neonatal UnitRoyal Brisbane and Women's HospitalBrisbaneQueenslandAustralia
| | - Amanda J. Ullman
- School of Nursing, Midwifery and Social WorkThe University of QueenslandBrisbaneQueenslandAustralia
- Centre for Children's Health ResearchChildren's Health Queensland Hospital and Health ServiceBrisbaneQueenslandAustralia
- School of Nursing and MidwiferyGriffith UniversityBrisbaneQueenslandAustralia
| |
Collapse
|
19
|
Trinh C, Thio M, Moss S, McGennisken M, Davis PG. Repeated intravenous cannula insertion attempts in neonates. Arch Dis Child Fetal Neonatal Ed 2022; 107:568-570. [PMID: 34489351 DOI: 10.1136/archdischild-2021-322538] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 08/25/2021] [Indexed: 11/03/2022]
Affiliation(s)
- Clement Trinh
- Newborn Research, The Royal Women's Hospital, Parkville, Victoria, Australia
| | - Marta Thio
- Newborn Research, The Royal Women's Hospital, Parkville, Victoria, Australia.,The Murdoch Children's Research Institute, Parkville, Victoria, Australia.,Department of Obstetrics and Gynaecology, The University of Melbourne, Parkville, Victoria, Australia
| | - Sally Moss
- Newborn Research, The Royal Women's Hospital, Parkville, Victoria, Australia
| | | | - Peter G Davis
- Newborn Research, The Royal Women's Hospital, Parkville, Victoria, Australia.,The Murdoch Children's Research Institute, Parkville, Victoria, Australia.,Department of Obstetrics and Gynaecology, The University of Melbourne, Parkville, Victoria, Australia
| |
Collapse
|
20
|
Prado NCDC, Menezes HFD, Sousa PAF, Lopes DCL, Santos FRD, Santos RSDC, Almino RHSC, Silva RARD. Terms of specialized nursing language in the care of the newborn with central venous catheter. Rev Bras Enferm 2022; 75:e20210572. [PMID: 35920494 DOI: 10.1590/0034-7167-2021-0572] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2021] [Accepted: 03/14/2022] [Indexed: 11/22/2022] Open
Abstract
OBJECTIVE To construct and validate a specialized nursing terminology for the care of newborns with peripherally inserted central venous catheters (PICC), based on the Betty Neuman Systems Model. METHODS Methodological study, carried out in a public maternity hospital, operationalized by the steps: extraction of terms from medical records of neonates using PICC; normalization; cross-mapping with the 2019/2020 version of ICNP®; organization in the Seven Axes; and content validation with nurses using content validity index and kappa coefficient. RESULTS 1,718 terms were extracted, and 372 relevant terms were normalized, with 265 constants and 107 non-constants. A total of 335 terms were validated, 246 of which were constant and 89 were not constant, which reached an agreement index and kappa ≥ 0.80. CONCLUSION Relevant terms were identified, which aid newborns using central venous catheters; thus, a terminological subset will be contributed to information in nursing practice.
Collapse
|
21
|
Osmond E, Williams N. Fifteen-minute consultation: Decision-making pathway for neonatal vascular access. Arch Dis Child Educ Pract Ed 2022; 107:242-245. [PMID: 33990374 DOI: 10.1136/archdischild-2020-320136] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/03/2020] [Revised: 01/08/2021] [Accepted: 04/14/2021] [Indexed: 11/03/2022]
Abstract
Newborn infants admitted for neonatal intensive and high dependency care are reliant on intravenous therapy for medications, hydration and nutrition. Adopting a structured approach to gaining neonatal vascular access can improve efficiency and potentially reduce complications. In this article, we discuss an algorithm for decision-making in neonatal vascular access.
Collapse
Affiliation(s)
- Elizabeth Osmond
- Neonatal Medicine, University Hospitals Bristol and Weston NHS Foundation Trust, Bristol, UK
| | - Nicholas Williams
- Neonatal Medicine, University Hospitals Bristol and Weston NHS Foundation Trust, Bristol, UK
| |
Collapse
|
22
|
Karaoğlan N, Çatikoğlu A, Yıldırım Sarı H, Devrim İ. Nurses' knowledge and experiences of peripheral intravenous catheter insertion at a tertiary paediatric health centre. BRITISH JOURNAL OF NURSING (MARK ALLEN PUBLISHING) 2022; 31:S18-S25. [PMID: 35856579 DOI: 10.12968/bjon.2022.31.14.s18] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
AIM The aim of the study was to determine paediatric nurses' knowledge and experiences of PIVC insertion. METHOD In this cross-sectional study, nurses working in a paediatric hospital in Izmir, Türkiye, between May and September 2019 were included (225; 67.4%). A PIVC knowledge and experience form, and a sociodemographic characteristics questionnaire were used to collect data. RESULTS Nurses most often inserted the PIVC on the dorsum of the hand (83.1%). Their choice of vein was influenced by the condition of the patient's veins (91.1%), medications (72%) and the patient's activity status (70.2%). The most preferred PIVC size was 24 gauge (98.2%), and the most frequently used cannula was a short peripheral cannula (96.9%). To clean the insertion site of the cannula, 93.8% of the nurses used 70% alcohol. Distractions used while inserting the PIVC were: letting the child play with a toy (51.1%), having the child sit on the mother's lap (45.8%), letting the child watch cartoons (45.3%), and administering oral sucrose (43.6%). Of the nurses, 69.3% attached a split septum/vein valve to the PIVC insertion site, and 82.2% cleaned the split septum/vein valve with 70% alcohol and waited until it dried before administering the medication. Some 79.6% secured the cannula with a hypoallergenic nonwoven adhesive fixation tape bandage. Some 94.7% performed catheter flushing for control after inserting PIVCs, 93.8% performed catheter flushing before IV fluid treatment, 89.8% flushed the catheter before drug administration through the bolus method, 53.3% flushed the PIVC catheter with a slow technique and 42.2% flushed it with an intermittent technique. CONCLUSION The nurses generally acted in accordance with Infusion Nurses Society (2016) guidance. It would be helpful if the hospital developed algorithms that include standards to prevent and manage PIVC insertions and complications.
Collapse
Affiliation(s)
- Nalan Karaoğlan
- Registered Nurse, Division of Pediatric Infectious Disease, Dr Behcet Uz Child Disease and Pediatric Surgery Training and Research Hospital, Izmir, Türkiye
| | - Aslı Çatikoğlu
- Registered Nurse, Division of Pediatric Infectious Disease, Dr Behcet Uz Child Disease and Pediatric Surgery Training and Research Hospital, Izmir, Türkiye
| | - Hatice Yıldırım Sarı
- Professor, Nursing Department, Health Sciences Faculty, Izmir Katip Celebi University, Izmir, Türkiye
| | - İlker Devrim
- Professor, Division of Pediatric Infectious Disease, Dr Behcet Uz Child Disease and Pediatric Surgery Training and Research Hospital, Izmir, Türkiye
| |
Collapse
|
23
|
Near-infrared system's efficiency for peripheral intravenous cannulation in a level III neonatal intensive care unit: a cross-sectional study. Eur J Pediatr 2022; 181:2747-2755. [PMID: 35482093 DOI: 10.1007/s00431-022-04480-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 04/09/2022] [Accepted: 04/15/2022] [Indexed: 11/03/2022]
Abstract
Venipuncture is a painful and invasive procedure for hospitalised newborns and represents a challenge for neonatal healthcare professionals. This study evaluated the most efficient cannulation method based on the proportion of success at the first attempt, standard care or near-infrared (NIR) device use, and pain assessment. An observational study with two arms was conducted in the neonatal intensive care unit (NICU) of a tertiary-care university hospital in Italy. All newborns undergoing peripheral vein cannulation and only nurses with more than 5 years of professional experience in the NICU were eligible for the first arm. Only newborns with a body weight of >2500 g at cannulation and all nurses working in the NICU were involved in the second arm. In the first arm of the study, no statistically significant differences between the NIR and control groups were found in terms of proportion of successful at the first attempt 60.6% (confidence interval [CI] 95%: 48.8; 72.4) vs. 56.1% (CI 95%: 44.1; 68.0) and the mean premature infant pain profile score 6.3 (CI 95%: 5.4-7.1) vs. 5.8 (CI 95%: 5.0-6.6). In the second arm, only among less experienced nurses (<1 year), we observed a significant increase in the proportion of success in the NIR group compared with the control group, nearly tripling the success rate (72.7% [54.1; 91.3] vs. 23.1% [0.2; 46.0]). Conclusion: This study reported no differences between the NIR and control groups. The results also suggest that using a NIR device may be advantageous for healthcare professionals with less experience during first-time cannulation. What is Known: • Venipuncture is a painful procedure commonly used to place a peripheral venous catheter for administering nutrients or drugs. • Near-infrared light facilitates the visualisation of veins and consequently, the performance of cannulation in the paediatric population. What is New: • The near-infrared light device was not associated with fewer attempts and a lower premature infant pain profile score in placing venous access in newborns than the traditional method. • The near-infrared light device could help nurses with less professional experience place a peripheral venous catheter.
Collapse
|
24
|
Peripheral intravenous catheter insertion and use of ultrasound in patients with difficult intravenous access: Australian patient and practitioner perspectives to inform future implementation strategies. PLoS One 2022; 17:e0269788. [PMID: 35749443 PMCID: PMC9231778 DOI: 10.1371/journal.pone.0269788] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2021] [Accepted: 05/23/2022] [Indexed: 11/30/2022] Open
Abstract
Objective To understand healthcare worker and patient experience with peripheral intravenous catheter (PIVC) insertion in patients with difficult intravenous access (DIVA) including the use of ultrasound (US). Methods Descriptive study using 1-on-1 semi-structured interviews conducted between August 2020 and January 2021. Purposeful sampling was used to recruit healthcare practitioners (HCPs) and patients with DIVA who had PIVC experience. Data were analysed using inductive thematic analysis. Interview data were than mapped to the implementation theory Behaviour Change Wheel to inform implementation strategies. Results In total 78 interviews (13 patients; 65 HCPs) were completed with respondents from metropolitan (60%), regional (25%) and rural/remote (15%) settings across Australia. Thematic analysis revealed 4 major themes: i) Harmful patient experiences persist, with patient insights not leveraged to effect change; ii) ‘Escalation’ is just a word on the front lines; iii) Heightened risk of insertion failure without resources and training; and iv) Paving the way forward–‘measures need to be in place to prevent failed insertion attempts. Themes were mapped to the behaviour change wheel and implementation strategies developed, these included: staff education, e-health record for DIVA identification, DIVA standard of care and DIVA guidelines to support escalation and ultrasound use. Conclusion(s) DIVA patients continue to have poor healthcare experiences with PIVC insertion. There is poor standardisation of DIVA assessment, escalation, US use and clinician education across hospitals. Quality, safety, and education improvement opportunities exist to improve the patient with DIVA experience and prevent traumatic insertions. We identified a number of implementation strategies to support future ultrasound and DIVA pathway implementation.
Collapse
|
25
|
Gupta K, Amboiram P, Balakrishnan U, C A, Abiramalatha T, Devi U. Dextrose Gel for Neonates at Risk With Asymptomatic Hypoglycemia: A Randomized Clinical Trial. Pediatrics 2022; 149:188021. [PMID: 35582897 DOI: 10.1542/peds.2021-050733] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 03/15/2022] [Indexed: 11/24/2022] Open
Abstract
BACKGROUND AND OBJECTIVES Hypoglycemia occurs in 5% to 15% of neonates in the first few days. A significant proportion requires admission for intravenous fluids. Dextrose gel may reduce admissions and mother-infant separation. We aimed to study the utility of dextrose gel in reducing the need for intravenous fluids. METHODS This stratified randomized control trial included at-risk infants with asymptomatic hypoglycemia. Study populations were stratified into 3 categories: small for gestational age (SGA) and intrauterine growth-restriction (IUGR), infants of diabetic mothers (IDM) and large for gestational age (LGA), and late preterm (LPT) neonates. Intervention group received dextrose gel followed by breastfeeding, and the control group (CG) received only breastfeeding. RESULTS Among 629 at-risk infants, 291 (46%) developed asymptomatic hypoglycemia; 147 (50.4%) in the dextrose gel group (DGG) and 144 (49.6%) in CG. There were 97, 98, and 96 infants in SGA/IUGR, IDM/LGA, and LPT categories, respectively. Treatment failure in the DGG was 17 (11.5%) compared to 58 (40.2%) in CG, with a risk ratio of 0.28 (95% confidence interval [CI]: 0.17-0.46; P < .001). Treatment failure was significantly less in DGG in all 3 categories: SGA/IUGR, IDM/LGA, and LPT with a risk ratio of 0.29 (95% CI:0.13-0.67), 0.31 (95% CI:0.14-0.66) and 0.24 (95% CI:0.09-0.66), respectively. CONCLUSIONS Dextrose gel reduces the need for intravenous fluids in at-risk neonates with asymptomatic hypoglycemia in the first 48 hours of life.
Collapse
|
26
|
Abstract
BACKGROUND Within every neonatal clinical setting, vascular access devices are considered essential for administration of fluids, nutrition, and medications. However, use of vascular access devices is not without danger of failure. Catheter securement adhesives are being evaluated among adult populations, but to date, studies in neonatal settings are scant. PURPOSE This research describes the prevalence of peripherally inserted central catheter failure related to catheter securement before and after the introduction of tissue adhesive for catheter securement. The identified modifiable risks might be used to evaluate efficacy, to innovate neonatal practice and support future policy developments. METHOD AND SETTING This was a retrospective observational analysis of routinely collected anonymized intravenous therapy-related data. The study was carried out at the tertiary neonatal intensive care unit (112 beds) of the Women's Wellness and Research Center of Hamad Medical Corporation, Doha, Qatar. RESULTS The results showed that the use of an approved medical grade adhesive for catheter securement resulted in significantly less therapy failures, compared with the control group. This remains significant after adjusting for day of insertion, gestational age, birth weight, and catheter type. IMPLICATIONS FOR PRACTICE AND RESEARCH In parallel with currently published international literature, this study's findings support catheter securement with an octyl-based tissue adhesive in use with central venous catheters. When device stabilization is most pertinent, securement with tissue adhesive is a safe and effective method for long-term vascular access among the neonatal population.
Collapse
|
27
|
Abstract
Extremely preterm infants are particularly vulnerable to systemic infections secondary to their immature immune defenses, prolonged hospitalizations, delays in enteral feeding, early antibiotic exposure, and need for life-sustaining invasive interventions. There have been several evidence-based practices for infection prevention in this population, such as human milk feedings, utilization of "bundle checklists" and decolonization of pathogenic organisms. Other practices, such as the use of probiotics, human milk-derived fortifiers, and antifungal prophylaxis are more controversial and require further investigation regarding the risks and benefits of such interventions. This chapter examines the susceptibility of the preterm newborn infant to invasive infections and describes several strategies for infection prevention, along with the associated limitations of such practices. It also addresses the various gaps in our understanding of preventing infections in this population, and the need for additional large multi-center randomized controlled trials. Additionally, the role of the SARs-CoV-2 global pandemic and associated strategies for infection prevention in the NICU are discussed.
Collapse
|
28
|
A Quality Improvement Initiative to Provide Timely Central Vascular Access in a Neonatal Intensive Care Unit. Adv Neonatal Care 2022; 22:203-209. [PMID: 34407057 DOI: 10.1097/anc.0000000000000941] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
BACKGROUND Timely central venous access is essential in the care of critically ill neonates. Peripherally inserted central catheters (PICCs) are the preferred form of central venous access when umbilical venous catheters cannot be placed or are discontinued. However, time delays increase risk for injury from peripheral intravenous lines and may contribute to inconsistent delivery of necessary fluids and medications. PURPOSE The aim of this quality improvement project was to decrease wait times for PICC placement in the neonatal intensive care unit (NICU). METHODS A unit-based PICC team was developed consisting of NICU nurses and attending neonatologists and implemented in 2 phases. Data were collected from chart reviews before, during, and after implementation of the team. We tracked time between PICC order and placement and number of attempts. Hospital metrics on peripheral intravenous line infiltrations and central line-associated blood stream infection were also monitored. At the end of the project, we continued tracking outcomes to determine whether gains would be sustained past the project period. RESULTS Implementation of a unit-based interdisciplinary specialty team led to a 50% reduction in mean PICC wait times from 1.2 days to 0.58 days. Benefits of the initiative were sustained past the initial project period. IMPLICATIONS FOR PRACTICE The development of a dedicated, local team played a key role in improving vascular access in the NICU. IMPLICATIONS FOR RESEARCH Proximity of specialized teams provides a solution to address gaps in care in the NICU.
Collapse
|
29
|
Karaoğlan N, Sarı HY, Devrim İ. Complications of peripheral intravenous catheters and risk factors for infiltration and phlebitis in children. BRITISH JOURNAL OF NURSING (MARK ALLEN PUBLISHING) 2022; 31:S14-S23. [PMID: 35439080 DOI: 10.12968/bjon.2022.31.8.s14] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
AIM This study aimed to identify the types of complications of peripheral intravenous catheters (PIVCs) in hospitalised children and possible risk factors for the development of extravasation, infiltration and phlebitis. METHOD The study was conducted in the largest children's hospital in a region of Turkey, with a bed capacity of 354 and 1400 employees, which provides care only to paediatric patients aged from newborn to 18 years old. In this 5-month prospective study, the complications of PIVCs in hospitalised children and risk factors leading to the development of extravasation, infiltration and phlebitis were recorded. During morning and afternoon daily visits, the researcher examined catheter sites for complications and indications for removal. RESULTS The study covered 244 patients aged from 1 month to 17 years, 575 PIVCs and 1600 catheter days. The rates of infiltration and phlebitis observed in children with PIVCs were 8.7 % and 15.8% respectively. Logistic regression revealed that using 22- and 24-gauge catheters, hospitalisation in the surgery ward and continuous infusion were significant independent risk factors for the development of infiltration (P<0.001). Direct logistic regression revealed that age in months, hospitalisation in a surgery ward and placement of the catheter in the veins of the antecubital fossa were significant independent risk factors for the development of phlebitis (P<0.001). CONCLUSION Catheter size, hospitalisation in the surgery ward and continuous infusion contributed to the development of infiltration. Age, hospitalisation in the surgery ward and catheter placement in the antecubital vein contributed to the development of phlebitis.
Collapse
Affiliation(s)
- Nalan Karaoğlan
- Nurse, Division of Pediatric Infectious Disease, Dr Behcet Uz Child Disease and Pediatric Surgery Training and Research Hospital, Izmir, Turkey
| | - Hatice Yıldırım Sarı
- Professor, Nursing Department, Health Sciences Faculty, Izmir Katip Celebi University, Izmir, Turkey
| | - İlker Devrim
- Professor, Division of Pediatric Infectious Disease, Dr Behcet Uz Child Disease and Pediatric Surgery Training and Research Hospital, Izmir, Turkey
| |
Collapse
|
30
|
van Rens M, Hugill K, Francia AL, Abdelwahab AH, Garcia KL. Treatment of a neonatal peripheral intravenous infiltration/extravasation (PIVIE) injury with hyaluronidase: a case report. BRITISH JOURNAL OF NURSING (MARK ALLEN PUBLISHING) 2022; 31:S31-S36. [PMID: 35439074 DOI: 10.12968/bjon.2022.31.8.s31] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
INTRODUCTION Intravenous therapy-related injury, its prevention, and treatment are ubiquitous topics of interest among neonatal clinicians and practitioners. This is due to the economic costs, reputational censure, and patents' wellbeing concerns coupled with the possibility of potentially avoidable serious and life-long harm occurring in this vulnerable patient population. CASE DESCRIPTION A term infant receiving a hypertonic dextrose infusion for the management of hypoglycemia developed a fulminating extravasation shortly after commencement of the infusion. This complication developed without notification of infusion pump pressure changes pertaining to a change in blood vessel compliance or early warning of infiltration by the optical sensor site monitoring technology (ivWatch®) in use. The injury was extensive and treated with a hyaluronidase/saline mix subcutaneously injected into the extravasation site using established techniques. Over a period of 2 weeks, the initially deep wound healed successfully without further incident, and the infant was discharged home without evident cosmetic scarring or functional effects. CONCLUSION This article reports on a case of a term baby who postroutine insertion of a peripherally intravenous catheter showed an extreme reaction to extravasation of the administered intravenous fluids. We discuss the condition, our successful management with hyaluronidase, and the need to remain observationally vigilant of intravenous infusions despite the advances in infusion monitoring technology. HIGHLIGHTS In a neonatal population peripheral infusion therapy-related complication rates have been reported to be as high as 75% Peripheral IV infiltration and extravasation (PIVIE) is implicated in up to 65% of IV-related complications PIVIE injury has the potential to cause serious harm Prompt recognition and timely appropriate intervention can mitigate many of these risks Adhering to the 5Rs for vascular access optimizes infusion therapy and potentially reduces complications.
Collapse
Affiliation(s)
- Matheus van Rens
- Nursing and Vascular Access, Neonatal Intensive Care Unit, Women's Wellness and Research Center, Hamad Medical Corporation, Doha, Qatar
| | - Kevin Hugill
- Nursing and Midwifery Education Department, Hamad Medical Corporation, Doha, Qatar
| | - Airene Lv Francia
- Vascular Access and Neonatal Transport, Neonatal Intensive Care Unit, Women's Wellness and Research Center, Hamad Medical Corporation, Doha, Qatar
| | | | - Krisha Lp Garcia
- Neonatal Intensive Care Unit, Women's Wellness and Research Center, Hamad Medical Corporation, Doha, Qatar
| |
Collapse
|
31
|
Evaluation of the Quality and Effect of 360° Safe Indwelling Infusion of Peripheral Venous Indwelling Needle in Pediatric Clinic. JOURNAL OF HEALTHCARE ENGINEERING 2022; 2022:1499927. [PMID: 35432822 PMCID: PMC9010149 DOI: 10.1155/2022/1499927] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Accepted: 03/24/2022] [Indexed: 11/26/2022]
Abstract
To evaluate the application effect of the 360° safe indwelling infusion program of peripheral venous indwelling needle in the infusion room of pediatric outpatient clinic. A total of 1,000 children who received indwelling needle infusion were randomly divided into experimental group (n = 500; 360° safe indwelling needle) and control group (n = 500; a routine indwelling needle). The incidence of indwelling needle-related complications and adverse events in the experimental group was significantly lower than that in the control group, and the number of indwelling days, indwelling needle usage rate, and parent satisfaction were significantly higher than those in the control group. The 360° safe indwelling infusion program can significantly reduce the incidence of complications and adverse events, and improve the quality of the indwelling needle infusion. The 360° safe indwelling infusion can effectively improve the comprehensive quality and safety of nursing care in the outpatient infusion room.
Collapse
|
32
|
Knowledge and Practices for Central Line Infection Prevention Among Brazilian Nurses: A Mixed-Methods Study. Adv Neonatal Care 2022; 22:180-187. [PMID: 35703927 DOI: 10.1097/anc.0000000000000893] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND The risk of central line-associated bloodstream infections (CLABSIs) increases when preventive guidelines are not adhered to. However, studies have generally been quantitative and aimed at determining the effectiveness of CLABSI prevention bundles. Few studies have used a mixed-methods approach to investigate nursing professionals' knowledge and practices regarding CLABSI prevention. PURPOSE To determine nursing professionals' knowledge and practices regarding CLABSI prevention and identify facilitators and barriers to adherence to CLABSI prevention strategies in a Brazilian neonatal intensive care unit. METHODS A mixed-methods approach was used. Nursing professionals answered questionnaires regarding knowledge and practices surrounding CLABSI prevention. Semistructured interviews explored barriers nursing professionals face that hinder adherence to CLABSI preventive practices. FINDINGS Nursing professionals had moderate knowledge regarding CLABSI prevention practices. Daily assessment of the continued need for central venous lines (CVLs), hub disinfection before and after handling, and hand hygiene before handling CVLs were practices less adhered to. Interviews revealed barriers to adherence to preventive practices included lack of adequate equipment, resources for hand hygiene, and inadequate physical structure. Increased education and awareness of safe CVL practices and accountability of the entire healthcare team may improve adherence to CLABSI prevention practices. Results of this study reinforce the importance of considering current nursing practices when developing strategies to increase adherence to CLABSI prevention guidelines. IMPLICATIONS FOR PRACTICE Providing continuing education may increase adherence to CLABSI prevention strategies. IMPLICATIONS FOR RESEARCH Research is needed to develop strategies aimed at increasing nursing adherence to CLABSI prevention strategies.
Collapse
|
33
|
McBride CA, Rahiman S, Schlapbach LJ, Schults JA, Kleidon TM, Kennedy M, Paterson RS, Byrnes J, Ware RS, Ullman AJ. Comparing ivWatch biosensor to standard care to identify extravasation injuries in the paediatric intensive care: a protocol for a randomised controlled trial. BMJ Open 2022; 12:e047765. [PMID: 35190407 PMCID: PMC8862432 DOI: 10.1136/bmjopen-2020-047765] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
INTRODUCTION Peripheral intravenous catheters (PIVCs) frequently fail during therapy administration, resulting in infusates pooling in the surrounding tissue. These extravasation injuries can cause significant pain, tissue destruction and scarring. ivWatch is a biosensor that uses visible and near-infrared light to measure tissue changes surrounding the PIVC and alert clinicians when extravasation may occur. The effectiveness of ivWatch, in comparison to clinical observation, in decreasing injury severity is unknown. The present study aims to investigate whether using ivWatch may potentially detect injury earlier and decrease the severity of PIVC extravasation injuries. METHODS AND ANALYSIS A single centre, parallel group, open-label superiority randomised controlled trial comparing (a) standard care (clinical observation) to (b) ivWatch monitoring in addition to standard care, to decrease the severity of extravasation injuries. 200 children with PIVCs inserted in the distal half of the limb, receiving intermediate-risk to high-risk infusates for ≥24 hours, will be consecutively recruited at a paediatric intensive care unit in Queensland, Australia. The primary outcome is extravasation severity, measured by the Cincinnati Children's Extravasation Harm Scale. Secondary outcomes include severity assessed with three-dimensional camera imaging, extravasation volume, treatment sequelae, the number of PIVCs used and dwell time, quality of life and healthcare costs. The between treatment difference in extravasation severity will be compared using ordinal logistic regression, with the treatment group included as the main effect, and reported with corresponding 95% CIs. Estimates of value will be presented as net monetary benefits and cost per reduction in extravasation injury severity, both presented with corresponding 95% credible intervals. ETHICS AND DISSEMINATION This study received approval from the Children's Health Queensland Hospital and Health Service Human Research Ethics Committee (HREC) (reference number: HREC/20/QCHQ/60867) and the Griffith University HREC (reference number: 2020/310) and will be disseminated via peer-reviewed publications and conference presentations. TRIAL REGISTRATION NUMBER ACTRN12620000317998.
Collapse
Affiliation(s)
- Craig Antony McBride
- Surgical Team: Infants, Toddlers, Children (STITCh), Queensland Children's Hospital, South Brisbane, Queensland, Australia
- Alliance for Vascular Access Teaching and Research Group, Griffith University, Nathan, Queensland, Australia
- Pegg Leditschke Children's Burns Centre, Children's Health Queensland, South Brisbane, Queensland, Australia
| | - Sarfaraz Rahiman
- Paediatric Intensive Care Unit, Queensland Children's Hospital, South Brisbane, Queensland, Australia
| | - Luregn J Schlapbach
- Paediatric Intensive Care Unit, Queensland Children's Hospital, South Brisbane, Queensland, Australia
- Department of Intensive Care Medicine and Neonatology, Children's Research Center, University Children's Hospital Zürich, Zurich, Switzerland
- Child Health Research Centre, The University of Queensland, South Brisbane, Queensland, Australia
| | - Jessica A Schults
- Alliance for Vascular Access Teaching and Research Group, Griffith University, Nathan, Queensland, Australia
- Paediatric Intensive Care Unit, Queensland Children's Hospital, South Brisbane, Queensland, Australia
- School of Nursing, Midwifery and Social Work, The University of Queensland, St Lucia, Queensland, Australia
- Herston Infectious Disease Institute, Metro North Health, Herston, Queensland, Australia
| | - Tricia M Kleidon
- Surgical Team: Infants, Toddlers, Children (STITCh), Queensland Children's Hospital, South Brisbane, Queensland, Australia
- Alliance for Vascular Access Teaching and Research Group, Griffith University, Nathan, Queensland, Australia
- School of Nursing, Midwifery and Social Work, The University of Queensland, St Lucia, Queensland, Australia
| | - Melanie Kennedy
- Paediatric Intensive Care Unit, Queensland Children's Hospital, South Brisbane, Queensland, Australia
| | - Rebecca S Paterson
- School of Nursing, Midwifery and Social Work, The University of Queensland, St Lucia, Queensland, Australia
| | - Joshua Byrnes
- Alliance for Vascular Access Teaching and Research Group, Griffith University, Nathan, Queensland, Australia
- Centre for Applied Health Economics, Menzies Health Institute, Griffith University, Southport, Queensland, Australia
| | - Robert S Ware
- Alliance for Vascular Access Teaching and Research Group, Griffith University, Nathan, Queensland, Australia
- Centre for Applied Health Economics, Menzies Health Institute, Griffith University, Southport, Queensland, Australia
| | - Amanda Judith Ullman
- Alliance for Vascular Access Teaching and Research Group, Griffith University, Nathan, Queensland, Australia
- Child Health Research Centre, The University of Queensland, South Brisbane, Queensland, Australia
- School of Nursing, Midwifery and Social Work, The University of Queensland, St Lucia, Queensland, Australia
| |
Collapse
|
34
|
van Rens MFPT, Bayoumi MAA, van de Hoogen A, Francia ALV, Cabanillas IJ, van Loon FHJ, Spencer TR. The ABBA project (Assess Better Before Access): A retrospective cohort study of neonatal intravascular device outcomes. Front Pediatr 2022; 10:980725. [PMID: 36405839 PMCID: PMC9670536 DOI: 10.3389/fped.2022.980725] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Accepted: 09/30/2022] [Indexed: 11/06/2022] Open
Abstract
BACKGROUND Venous access devices (VADs) play a vital role within the neonatal intensive care unit. However, there are significant risks associated with the use of VADs, with complications such as infection, thrombosis, device occlusion, and infiltration/extravasation frequently contributing to device-related failures and increasing the risk of significant patient harm or injury. This study aimed to explore the relationships between risk factors and different venous access device complications in the neonatal setting, and then use that evidence to develop an algorithm based on observational data. METHODS This is a retrospective, single-center cohort study that was conducted in a large 112-bed neonatal intensive care unit in Qatar. We examined venous access device data from January 2016 to December 2018 for all term and preterm neonates. Descriptive statistics were used to summarize the outcomes, which included a mean and its standard deviation or median and an interquartile range for continuous variables regarding normal distribution, and absolute numbers with percentages for discrete variables. RESULTS The authors recorded a total of 23,858 VADs inserted during the study period. Of these, 21,313 (89%) were peripheral intravenous catheters, 689 (3%) were extended dwell-peripheral intravenous catheters, 1,335 (6%) were epicutaneo-caval catheters, and 521 (2%) were umbilical venous catheters. In total, 51,179 catheter days were registered, with 2.17 catheter days reported per patient. Peripheral device dwell times were significantly shorter when compared with central venous catheter devices (P < 0.001), with mean dwell times of 22 days ± 23 h and 236 days ± 183 h, respectively. After insertion, a complication occurred in 11,177 (51%) of peripheral VADs and 221 (12%) of central VADs. The type of device inserted [P < 0.001, hazard ratio (HR) = 0.52, 95% confidence interval (CI): 0.50-0.54], reason/indication for intravenous therapy (P < 0.001, HR = 0.85, 95% CI: 0.82-0.87), and the side of insertion of the device (P < 0.001, HR = 1.25, 95% CI: 1.24-1.27) had a significant relationship with outcomes. CONCLUSIONS Four subgroups of VADs were identified (peripheral intravenous catheters, extended dwell-peripheral intravenous devices, epicutaneo-caval catheters, and umbilical venous catheters) with outcome-related differences. Central venous access devices (epicutaneo-caval catheters and umbilical venous catheters) had lower complications compared with peripheral VADs. Proper venous access device selection, early insertion, and early removal approaches remain crucial to preventing venous access device complications. Peripheral intravenous devices should be used carefully and closely watched for early detection of complications.
Collapse
Affiliation(s)
- Matheus F P T van Rens
- Neonatal Intensive Care Unit, Women's Wellness and Research Center, Hamad Medical Corporation, Doha, Qatar
| | - Mohammad A A Bayoumi
- Neonatal Intensive Care Unit, Women's Wellness and Research Center, Hamad Medical Corporation, Doha, Qatar
| | - Agnes van de Hoogen
- Department of Neonatology, Wilhelmina Children's Hospital, University Medical Centre of Utrecht, Utrecht, Netherlands
| | - Airene L V Francia
- Neonatal Intensive Care Unit, Women's Wellness and Research Center, Hamad Medical Corporation, Doha, Qatar
| | - Irian J Cabanillas
- Neonatal Intensive Care Unit, Women's Wellness and Research Center, Hamad Medical Corporation, Doha, Qatar
| | - Fredericus H J van Loon
- Department of Science and Technology in Perioperative Nursing, Fontys University of Applied Sciences, Eindhoven, Netherlands
| | - Timothy R Spencer
- Nursing Department, Global Vascular Access, LLC, Scottsdale, AZ, United States
| |
Collapse
|
35
|
Dramowski A, Aucamp M, Beales E, Bekker A, Cotton MF, Fitzgerald FC, Labi AK, Russell N, Strysko J, Whitelaw A, Coffin S. Healthcare-Associated Infection Prevention Interventions for Neonates in Resource-Limited Settings. Front Pediatr 2022; 10:919403. [PMID: 35874586 PMCID: PMC9301049 DOI: 10.3389/fped.2022.919403] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/13/2022] [Accepted: 06/02/2022] [Indexed: 11/13/2022] Open
Abstract
Healthcare-associated infections (HAIs) and antimicrobial-resistant (AMR) infections are leading causes of neonatal morbidity and mortality, contributing to an extended hospital stay and increased healthcare costs. Although the burden and impact of HAI/AMR in resource-limited neonatal units are substantial, there are few HAI/AMR prevention studies in these settings. We reviewed the mechanism of action and evidence supporting HAI/AMR prevention interventions, including care bundles, for hospitalized neonates in low- and middle-income countries (LMIC).
Collapse
Affiliation(s)
- Angela Dramowski
- Department of Paediatrics and Child Health, Faculty of Medicine and Health Sciences, Stellenbosch University, Cape Town, South Africa
| | - Marina Aucamp
- Infection Prevention and Control Service, Mowbray Maternity Hospital, Cape Town, South Africa
| | - Emily Beales
- Center for Neonatal and Pediatric Infection, St George's University of London, London, United Kingdom
| | - Adrie Bekker
- Department of Paediatrics and Child Health, Faculty of Medicine and Health Sciences, Stellenbosch University, Cape Town, South Africa
| | - Mark Frederic Cotton
- Department of Paediatrics and Child Health, Faculty of Medicine and Health Sciences, Stellenbosch University, Cape Town, South Africa
| | - Felicity C Fitzgerald
- Infection, Immunity and Inflammation, UCL Great Ormond Street Institute of Child Health, University College London, London, United Kingdom
| | - Appiah-Korang Labi
- Department of Medical Microbiology, University of Ghana Medical School, Accra, Ghana
| | - Neal Russell
- Center for Neonatal and Pediatric Infection, St George's University of London, London, United Kingdom
| | - Jonathan Strysko
- Department of Paediatric and Adolescent Health, Princess Marina Hospital, Gaborone, Botswana.,Department of Global Medicine, Children's Hospital of Philadelphia, Philadelphia, PA, United States
| | - Andrew Whitelaw
- Division of Medical Microbiology, Faculty of Medicine and Health Sciences, Stellenbosch University, Stellenbosch, South Africa.,National Health Laboratory Service, Tygerberg Hospital, Cape Town, South Africa
| | - Susan Coffin
- Division of Infectious Diseases, Department of Pediatrics, Children's Hospital of Philadelphia, Philadelphia, PA, United States
| |
Collapse
|
36
|
Prado NCDC, Menezes HFD, Sousa PAF, Lopes DCL, Santos FRD, Santos RSDC, Almino RHSC, Silva RARD. Termos da linguagem especializada de enfermagem no cuidado ao recém-nascido com cateter venoso central. Rev Bras Enferm 2022. [DOI: 10.1590/0034-7167-2021-0572pt] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
RESUMO Objetivo: Construir e validar uma terminologia especializada de enfermagem para o cuidado a recém-nascidos com cateter venoso central de inserção periférica (PICC), com base no Modelo de Sistemas de Betty Neuman. Métodos: Estudo metodológico, realizado em uma maternidade pública, operacionalizado pelas etapas: extração dos termos de prontuários de neonatos em uso de PICC; normalização; mapeamento cruzado com a versão 2019/2020 da CIPE®; organização nos Sete Eixos; e validação de conteúdo com enfermeiros usando-se índice de validade de conteúdo e coeficiente kappa. Resultados: Extraíram-se 1.718 termos, sendo normalizados 372 termos pertinentes, estando 265 constantes e 107 não constantes. Foram validados 335 termos, sendo 246 constantes e 89 não constantes, os quais atingiram um índice de concordância e kappa ≥ 0,80. Conclusão: Identificaramse termos relevantes, que oportunizam a assistência aos recém-nascidos em uso de cateter venoso central; assim se contribuirá com um subconjunto terminológico para a informação na prática de enfermagem.
Collapse
|
37
|
Frunza IF, Boyar V, Fishbein J, Kurepa D. Correlation between visual inspection/physical exam and point-of-care ultrasound exam in the evaluation of neonatal peripheral intravenous catheter site. J Matern Fetal Neonatal Med 2021; 35:8552-8558. [PMID: 34632914 DOI: 10.1080/14767058.2021.1988564] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
BACKGROUND A peripheral intravenous catheter (PIVC) is used to administer IV fluids and medications. The most common PIVC complication is peripheral intravenous extravasation and infiltration (PIVE/I). Early visual inspection and physical exam (VI/PE) of the insertion site performed by a registered nurse (RN) are essential to prevent or limit tissue damage caused by displaced PIV catheters. Skin ultrasound (US) of the PIVC site provides rapid, real-time, high-resolution images of the anatomic structures at the point of care (POC). OBJECTIVES To correlate the standard practice of clinical assessment (VI/PE) with POC-US exam to determine the location and function of PIVC suspicious for malfunctioning. DESIGN/METHODS PIVC sites suspicious of malfunctioning were assessed by RN and findings were recorded in the electronic medical record. POC-US exam of the PIVC site was performed immediately after VI/PE. Sonographic exam included B-mode assessment of the PIVC site subcutaneous tissue characteristics and PIVC location as assessed by the Doppler flow tracing during RN's normal saline flush. RN's decision to continue or discontinue the PIVC was based solely on her/his VI/PE. RESULTS Forty-four infants were studied. We found sufficient disagreement between the two methodologies (p = .0074), with discordance noted in 15 (34.1%) cases. In 29 (65.9%) cases there was concordance between VI/PE and POC-US, 18 to remove and 11 not to remove PIVC (Gwet AC1 correlation coefficient = 0.34). There was no significant correlation between VI/PE finding of tissue edema, the most common initial clinical evaluation sign, and POC-US finding of tissue edema or fluid pockets (p = .67, p = .21 respectively). RN's findings during the PIVC flush with normal saline (NS) were in perfect agreement with the findings of the Doppler signal on POC-US (Gwet's AC1 = 0.82) as well as with the final US-based decision to remove PIVC (p < .0001). CONCLUSION We found only a fair correlation between RN's VI/PE of the suspicious PIVC site and the POC-US exam of the same site. However, our data suggest that in the evaluation of questionable PIVC, POC-US could be used in conjunction with VI/PE. This combination may improve the accuracy of decisions to remove or maintain PIVCs, which will result in a decreased number of PIVC placement attempts and complications.
Collapse
Affiliation(s)
- Ioan-Florinel Frunza
- Division of Neonatal-Perinatal Medicine, Cohen Children's Medical Center, New Hyde Park, NY, USA
| | - Vitaliya Boyar
- Division of Neonatal-Perinatal Medicine, Cohen Children's Medical Center, New Hyde Park, NY, USA
| | - Joanna Fishbein
- The Feinstein Institutes for Medical Research, Manhasset, NY, USA
| | - Dalibor Kurepa
- Division of Neonatal-Perinatal Medicine, Cohen Children's Medical Center, New Hyde Park, NY, USA
| |
Collapse
|
38
|
van Rens MFPT, Hugill K, Mahmah MA, Bayoumi M, Francia ALV, Garcia KLP, van Loon FHJ. Evaluation of unmodifiable and potentially modifiable factors affecting peripheral intravenous device-related complications in neonates: a retrospective observational study. BMJ Open 2021; 11:e047788. [PMID: 34497079 PMCID: PMC8438911 DOI: 10.1136/bmjopen-2020-047788] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
Abstract
OBJECTIVES Infants in neonatal units benefit from dependable peripheral intravenous access. However, peripheral intravenous access exposes infants to high rates of clinically minor and serious complications. Despite this, little is known about the interplay of risk factors. The aim of this study was to assess the incidence and evaluate the interactions of risk factors on the occurrence of peripheral intravenous complications in a neonatal population. DESIGN This was a retrospective observational study. SETTING The study was performed on the neonatal intensive care unit of the Women's Wellness and Research Center, Hamad Medical Corporation, Qatar, as a single-site study. PARTICIPANTS This study included 12 978 neonates who required intravenous therapy. OUTCOME MEASUREMENTS The main outcome was the occurrence of any peripheral intravenous cannulation failure, leading to unplanned removal of the device before completion of the intended intravenous therapy. RESULTS A mean dwell time of 36±28 hours was recorded in participants with no complications, whereas the mean dwell time was 31±23 hours in participants with an indication for premature removal of the peripheral intravenous catheter (PIVC) (p<0.001, t=11.35). Unplanned removal occurred in 59% of cases; the overall complication rate was 18 per 1000 catheter days. Unmodifiable factors affecting PIVC dwell time include lower birth (HR=0.23, 0.20 to 0.28, p<0.001) and current body weight (HR=1.06, 1.03 to 1.10, p=0.018). Cannulation site (HR=1.23, 1.16 to 1.30, p<0.001), the inserted device (HR=0.89, 0.84 to 0.94, p<0.001) and the indication for intravenous treatment (HR=0.76, 0.73 to 0.79, p<0.001) were modifiable factors. CONCLUSION Most infants experienced a vascular access-related complication. Given the high complication rate, PIVCs should be used judiciously and thought given prior to their use as to whether alternate means of intravenous access might be more appropriate.
Collapse
Affiliation(s)
- Matheus F P T van Rens
- Neonatal Intensive Care Unit, Women's Wellness and Research Center, Hamad Medical Corporation, Doha, Qatar
| | - Kevin Hugill
- Neonatal Intensive Care Unit, Women's Wellness and Research Center, Hamad Medical Corporation, Doha, Qatar
| | - Mohamad A Mahmah
- Neonatal Intensive Care Unit, Women's Wellness and Research Center, Hamad Medical Corporation, Doha, Qatar
| | - Mohammad Bayoumi
- Neonatal Intensive Care Unit, Women's Wellness and Research Center, Hamad Medical Corporation, Doha, Qatar
| | - Airene L V Francia
- Neonatal Intensive Care Unit, Women's Wellness and Research Center, Hamad Medical Corporation, Doha, Qatar
| | - Krisha L P Garcia
- Neonatal Intensive Care Unit, Women's Wellness and Research Center, Hamad Medical Corporation, Doha, Qatar
| | - F H J van Loon
- PeriOperative Care & Technology, Fontys University of Applied Sciences, Eindhoven, The Netherlands
- Anesthesiology, Intensive Care and Pain Medicine, Catharina Hospital, Eindhoven, Netherlands
| |
Collapse
|
39
|
Handayani RN, Efendi D. The impact of multiple insertions on peripheral intravenous access in low-birth-weight infants in perinatology. LA PEDIATRIA MEDICA E CHIRURGICA 2021; 43. [PMID: 37184325 DOI: 10.4081/pmc.2021.266] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2021] [Indexed: 11/23/2022] Open
Abstract
Low-Birth-Weight (LBW) infants have very small veins, and there is a risk of needing multiple insertions to establish peripheral intravenous access. This study aimed to examine the impacts of multiple insertions during peripheral intravenous access in LBW infants. This cross-sectional study involved 216 respondents. Data were analyzed with the Spearman correlation. The results showed a significant relationship (p<α) between multiple insertions to establish peripheral intravenous access to LBW infants with increased pain, heart rate, respiratory rate, duration of crying, delayed treatment, duration of insertion, and high cost of care (p<0.001; r=0.358-0.836). Meanwhile, multiple insertions might decrease oxygen saturation and body temperature (p<0.001; r=0.358). In this study, multiple insertions were correlated with several negative impacts on the physiological function and discomfort of LBW infants. The study also highlights the effect on time of treatment precision and cost effectiveness. Recommendation: It is necessary to develop preventive measures to reduce the impact of multiple insertions to establish peripheral intravenous access in LBW infants.
Collapse
|
40
|
Santos LMD, Silva CSGE, Cerqueira ÉAC, Gomes AS, Carvalho ESDS. Construction and validation of a family guidance manual on complications of intravenous therapy in children. Rev Bras Enferm 2021; 74:e20190688. [PMID: 33787774 DOI: 10.1590/0034-7167-2019-0688] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2019] [Accepted: 09/09/2020] [Indexed: 11/21/2022] Open
Abstract
OBJECTIVES to build and validate the content of an educational manual for the inclusion of family members of hospitalized children in the prevention and early identification of complications associated with IVT through the peripheral route. METHODS it was a methodological study of construction and validation of the content of an instructional material. The validation process took place using the Delphi Technique, adopting a content validation index equal to or greater than 0.80 as a desirable consensus. RESULTS the handbook was validated in the second assessment round in all categories: content, language, illustration, layout, motivation, culture, and applicability. The Global Content Validation Index was 0.98. CONCLUSIONS because of the high values obtained (> 0.8), after the second evaluation, the handbook is considered validated in terms of content, by expert judges.
Collapse
Affiliation(s)
| | | | | | - Aline Silva Gomes
- Universidade Estadual de Feira de Santana. Feira de Santana, Bahia, Brazil
| | | |
Collapse
|
41
|
Chau JPC, Lo SHS, Chan KM, Chan MY, Lee VWY, Lam SKY, Choi KC, Thompson DR. Development and evaluation of a technology-enhanced, enquiry-based learning program on managing neonatal extravasation injury: A pre-test/post-test mixed-methods study. NURSE EDUCATION TODAY 2021; 97:104672. [PMID: 33278729 DOI: 10.1016/j.nedt.2020.104672] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/15/2020] [Revised: 10/02/2020] [Accepted: 11/12/2020] [Indexed: 06/12/2023]
Abstract
BACKGROUND Extravasation injury remains a significant preventable cause of morbidity and mortality in neonates. Equipping nursing students with the requisite knowledge and skills is essential for appropriate prevention, early detection, and management of extravasation injury. OBJECTIVES To develop a technology-enhanced, enquiry-based learning program for nursing students on the prevention and management of neonatal extravasation injury and examine its impact on their knowledge, approaches to studying and experience of learning. DESIGN A pre-test/post-test study with qualitative evaluation. SETTINGS Two university pre-registration nursing programs in Hong Kong. PARTICIPANTS A total of 192 senior-year nursing students. METHODS A novel learning program was developed comprising 25 scenario-based video vignettes supplemented with critical-thinking exercises, discussion guides, interactive games, reading materials and a 3-hour in-class interactive workshop. Students received unlimited online access to the program. Data were collected at baseline and one-month post-workshop. Outcomes were students' level of knowledge of prevention and management of extravasation injuries and related care, approaches to studying, and experience of learning. Paired t-tests were performed on pre- post-test outcome data and individual semi-structured interviews were conducted at one-month post-workshop, transcribed verbatim and analyzed thematically. RESULTS There were statistically significant improvements in students' level of knowledge and use of a deep approach to learning at one month compared with baseline. Students were highly satisfied with the program, appreciating the video vignettes and interactive small group discussions with academics and clinicians. Suggestions for enhancing the program included more time for the workshop, interaction with clinicians, and details on the administration of neonatal medications and dosages. CONCLUSIONS This study showed that a novel technology-enhanced, enquiry-based learning program was effective in enhancing nursing students' knowledge of the prevention and management of neonatal extravasation injury, approaches to studying and experience of learning.
Collapse
Affiliation(s)
- Janita P C Chau
- The Nethersole School of Nursing, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong.
| | - Suzanne H S Lo
- The Nethersole School of Nursing, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong.
| | - Kam Ming Chan
- Department of Paediatrics and Adolescent Medicine, United Christian Hospital, Hospital Authority, Hong Kong.
| | - Man Yi Chan
- Department of Paediatrics and Adolescent Medicine, Princess Margaret Hospital, Hospital Authority, Hong Kong.
| | - Vivian W Y Lee
- Centre for Learning Enhancement And Research, The Chinese University of Hong Kong, Hong Kong.
| | - Simon K Y Lam
- The Nethersole School of Nursing, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong.
| | - Kai Chow Choi
- The Nethersole School of Nursing, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong.
| | - David R Thompson
- School of Nursing and Midwifery, Queen's University Belfast, Belfast, United Kingdom.
| |
Collapse
|
42
|
Fleiss N, Klein-Cloud R, Gill B, Feldstein NA, Fallon EM, Ruzal-Shapiro C, Collins A. Subdural extravasation of crystalloids and blood products through a scalp peripheral intravenous catheter into the subdural space of a neonate on veno-arterial extracorporeal membrane oxygenation. J Neonatal Perinatal Med 2021; 14:601-605. [PMID: 33523026 DOI: 10.3233/npm-200610] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
We describe a rare and devastating complication of a malpositioned scalp peripheral intravenous catheter (PIV) that resulted in subdural extravasation of infused fluids and midline shift in a critically ill neonate who required extracorporeal membrane oxygenation (ECMO). Recognition of increased intracranial pressure was hindered by the hemodynamic changes of being on ECMO and only identified by routine surveillance ultrasonography. Awareness of this complication may lead providers to seek alternate sites for vascular access in such patients, and encourage closer monitoring for this complication when an alternate site is unavailable.
Collapse
Affiliation(s)
- N Fleiss
- Department of Pediatrics, Columbia University Irving Medical Center, New York Presbyterian Hospital, New York, NY, USA
| | - R Klein-Cloud
- Department of Surgery, Columbia University Irving Medical Center, New York Presbyterian Hospital, New York, NY, USA
| | - B Gill
- Department of Neurosurgery, Columbia University Irving Medical Center, New York Presbyterian Hospital, New York, NY, USA
| | - N A Feldstein
- Department of Neurosurgery, Columbia University Irving Medical Center, New York Presbyterian Hospital, New York, NY, USA
| | - E M Fallon
- Department of Surgery, Columbia University Irving Medical Center, New York Presbyterian Hospital, New York, NY, USA
| | - C Ruzal-Shapiro
- Department of Radiology, Columbia University Irving Medical Center, New York Presbyterian Hospital, New York, NY, USA
| | - A Collins
- Department of Pediatrics, Columbia University Irving Medical Center, New York Presbyterian Hospital, New York, NY, USA
| |
Collapse
|
43
|
Balachander B, Rajesh D, Pinto BV, Stevens S, Rao Pn S. Simulation training to improve aseptic non-touch technique and success during intravenous cannulation-effect on hospital-acquired blood stream infection and knowledge retention after 6 months: The snowball effect theory. J Vasc Access 2020; 22:353-358. [PMID: 32667233 DOI: 10.1177/1129729820938202] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
BACKGROUND Intravenous cannulation is a common procedure and a valuable skill in the neonatal intensive care unit. Standardized procedure and personnel training are needed in the unit to prevent hospital-acquired blood stream infections. Hence, we evaluated the effect of training using a low-fidelity simulation on the improvement of the aseptic non-touch technique during intravenous cannulation and knowledge retention after 6 months. METHODS The study was conducted in a tertiary care neonatal unit from June 2017 to July 2018. All the staff nurses and junior resident doctors posted in the neonatal intensive care were included in the study. A protocol and checklist score sheet was developed. The score sheet consisted of 23 items with a total score of 46. Participants were expected to obtain a minimum of 80%. A pre-test was conducted initially, followed by a formal training and then a post-test. The NITA newborn venous access mannequin was used to facilitate the training. A re-training for new nurses was conducted after 6 months. Data were analyzed using paired t-test. RESULTS A total of 29 doctors and nurses were enrolled in the training. The mean pre-test score was 29.93 compared to 42.66 in the post-test scores (mean difference 12.24(95% confidence interval: 9.39-16.05), p < 0.01. The mean scores were higher when the simulation was conducted after 6 months. There was a significant decline in blood stream infection rates from 5.5 to 1.65 per 1000 patient days (p = 0.05). CONCLUSION Simulation-based training of health care personnel is a good modality to improve aseptic non-touch technique during intravenous cannulation in the neonatal intensive care unit. Simulation-based training also helps in knowledge retention and standardization of training procedures.
Collapse
Affiliation(s)
- Bharathi Balachander
- Department of Neonatology, St. John's Medical College Hospital, Bengaluru, India
| | - Deepa Rajesh
- Department of Neonatology, St. John's Medical College Hospital, Bengaluru, India
| | - Bonita Viona Pinto
- Department of Neonatology, St. John's Medical College Hospital, Bengaluru, India
| | - Sofia Stevens
- Department of Neonatology, St. John's Medical College Hospital, Bengaluru, India
| | - Suman Rao Pn
- Department of Neonatology, St. John's Medical College Hospital, Bengaluru, India
| |
Collapse
|
44
|
Bayoumi MAA, Van Rens MFP, Chandra P, Francia ALV, D'Souza S, George M, Shahbal S, Elmalik EE, Cabanillas IJE. Effect of implementing an Epicutaneo-Caval Catheter team in Neonatal Intensive Care Unit. J Vasc Access 2020; 22:243-253. [PMID: 32602399 PMCID: PMC7983328 DOI: 10.1177/1129729820928182] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
Background: Until the 1980s, central vascular access in the Neonatal Intensive Care Unit was predominantly delivered by umbilical catheters and only and if needed by surgical cutdowns or subclavian vein catheterization through blind percutaneous venipuncture. In the early 1980s, epicutaneo-caval catheters were successfully introduced. Methods: In our Neonatal Intensive Care Unit, a dedicated team to insert epicutaneo-caval catheters was formally established in January 2017, including 12 neonatologists and 1 neonatal nurse practitioner. A before- versus after-intervention study was designed to determine whether the establishment of the epicutaneo-caval catheter insertion team is associated with increased success rates and a decreased risk of catheter-related complications. Success rates and other catheter-related parameters were traced from 2016 onward. Collected data were analyzed for three consecutive years: 2016, 2017, and 2018. Results: The epicutaneo-caval catheter team inserted 1336 catheters over 3 years. Both first prick (from 57.7% to 66.9%; p = 0.023) and overall success (from 81.7% to 97.6%; p < 0.0001) rates significantly improved. In 2018, the number of tunneled or surgically inserted central venous catheters came down to zero (p < 0.0001). Overall catheter-related complications were significantly lower following the epicutaneo-caval catheter team’s establishment (p < 0.0001) while there was no significant decrease noted (p = 0.978) in central line–associated bacterial stream infection rates. Conclusion: A dedicated epicutaneo-caval catheter team is a promising intervention to increase success rates and significantly decrease catheter-related complications in Neonatal Intensive Care Unit. Standardizing epicutaneo-caval catheter placement is important; however, standardizing catheter maintenance seems essential to the improvement of central line–associated bacterial stream infection rates.
Collapse
Affiliation(s)
- Mohammad A A Bayoumi
- Neonatal Intensive Care Unit (NICU), Women's Wellness and Research Center (WWRC), Hamad Medical Corporation (HMC), Doha, Qatar
| | - Matheus F P Van Rens
- Neonatal Intensive Care Unit (NICU), Women's Wellness and Research Center (WWRC), Hamad Medical Corporation (HMC), Doha, Qatar
| | - Prem Chandra
- Medical Research Center, Hamad Medical Corporation (HMC), Doha, Qatar
| | - Airene L V Francia
- Neonatal Intensive Care Unit (NICU), Women's Wellness and Research Center (WWRC), Hamad Medical Corporation (HMC), Doha, Qatar
| | - Sunitha D'Souza
- Neonatal Intensive Care Unit (NICU), Women's Wellness and Research Center (WWRC), Hamad Medical Corporation (HMC), Doha, Qatar
| | - Majee George
- Neonatal Intensive Care Unit (NICU), Women's Wellness and Research Center (WWRC), Hamad Medical Corporation (HMC), Doha, Qatar
| | - Saad Shahbal
- Medical Research Center, Hamad Medical Corporation (HMC), Doha, Qatar
| | - Einas E Elmalik
- Neonatal Intensive Care Unit (NICU), Women's Wellness and Research Center (WWRC), Hamad Medical Corporation (HMC), Doha, Qatar
| | - Irian J E Cabanillas
- Neonatal Intensive Care Unit (NICU), Women's Wellness and Research Center (WWRC), Hamad Medical Corporation (HMC), Doha, Qatar
| |
Collapse
|
45
|
Yuningsih R, Rustina Y, Efendi D. The related factors of phlebitis among low birth weight infants in perinatology ward. Pediatr Rep 2020; 12:8691. [PMID: 32905236 PMCID: PMC7463142 DOI: 10.4081/pr.2020.8691] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/16/2020] [Indexed: 11/23/2022] Open
Abstract
Peripheral intravenous line placement might lead to some risks and complications in low birth weight (LBW) infants including phlebitis, which shows varying percentages. This study aimed to analyze the causative factors of phlebitis among LBW infants in a perinatology ward. A total of 106 LBW infants who selected using a consecutive sampling technique were analyzed with cross-sectional method. Data were collected when LBW infants started receiving infusions until the infusion was stopped under certain conditions, using the Infusion Nurses Society (INS) phlebitis scale and the Neonatal Infant Pain Scale (NIPS) as the instrument. The variables related to phlebitis under bivariate analysis included the clinical experience of intravenous insertion, infusion pumps, site of insertion, neonatal birth weight, and the administration of total parenteral nutrition. The most significant risk factor of phlebitis was the nurses' clinical experience of intravenous insertion (< 2 years). Therefore, the results of this study can be considered to improve the quality of nursing care in perinatology ward.
Collapse
Affiliation(s)
- Risna Yuningsih
- Faculty of Nusing, Universitas Indonesia.,dr. Dradjat Prawiranegara General Hospital Serang-Banten
| | | | - Defi Efendi
- Faculty of Nusing, Universitas Indonesia.,Neonatal Intensive Care Unit, Universitas Indonesia Hospital, Indonesia
| |
Collapse
|
46
|
Liew DD, Zhou L, Chin LY, Davies-Tuck M, Malhotra A. Elective replacement of peripheral intravenous cannulas in neonates. J Vasc Access 2020; 22:121-128. [PMID: 32524888 DOI: 10.1177/1129729820927235] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
BACKGROUND Newborns admitted to neonatal units often require vascular access. Peripheral intravenous cannulas allow essential medication, fluids, and/or parenteral nutrition to be delivered. Peripheral intravenous cannulas are often associated with complications, such as extravasation, infiltration, phlebitis, leakage, spontaneous dislodgement, and catheter-associated blood stream infection. METHODS A secondary analysis of a randomized controlled trial evaluating standard replacement versus elective replacement (72-96 h) of peripheral intravenous cannula was conducted in a tertiary-level neonatal unit in Melbourne, Australia. The main outcome of this analysis was to assess the risk of combined adverse events associated with elective replacement of peripheral intravenous cannula. A cost analysis of the intervention was also conducted. RESULTS Combined adverse outcomes noted per infant were 48 (87.27%) in the standard replacement group versus 44 (75.86%) in the elective replacement group (RR 0.87; 95% CI 0.71-1.04, p = 0.15). In terms of combined adverse outcome per 1000 intravenous hours, there was a significant risk ratio of 0.81 in the elective group compared with the standard group (95% CI 0.65-0.98, p = 0.04). Gestation (adjusted odds ratio (AOR) 0.58; 95% CI 0.35-0.96, p = 0.03), male gender (AOR 4.65; 95% CI 1.07-20.28, p = 0.04), elective replacement (AOR 0.12; 95% CI 0.03-0.68, p = 0.01), and the total number of re-sites (AOR 27.84; 95% CI 4.61-168.18, p < 0.001) were significant risk factors associated with adverse events. There were also significantly higher costs involved with elective replacement. CONCLUSION Elective replacement of peripheral intravenous cannulas was not shown to reduce the risk of combined adverse events. Elective peripheral intravenous cannula replacement also incurred a higher cost.
Collapse
Affiliation(s)
| | - Lindsay Zhou
- Monash Newborn, Monash Children's Hospital, Melbourne, VIC, Australia
| | - Li Yen Chin
- Monash Newborn, Monash Children's Hospital, Melbourne, VIC, Australia
| | - Miranda Davies-Tuck
- The Ritchie Centre, Hudson Institute of Medical Research, Melbourne, VIC, Australia
| | - Atul Malhotra
- Department of Paediatrics, Monash University, Melbourne, VIC, Australia.,Monash Newborn, Monash Children's Hospital, Melbourne, VIC, Australia.,The Ritchie Centre, Hudson Institute of Medical Research, Melbourne, VIC, Australia
| |
Collapse
|
47
|
Hede SV, DeVore G, Satou G, Sklansky M. Neonatal management of prenatally suspected coarctation of the aorta. Prenat Diagn 2020; 40:942-948. [PMID: 32277716 DOI: 10.1002/pd.5696] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2019] [Revised: 03/24/2020] [Accepted: 03/28/2020] [Indexed: 11/09/2022]
Abstract
OBJECTIVES (a) To determine the false-positive rate among newborns with prenatally suspected coarctation of the aorta (CoA) within the UCLA Health system, (b) to compare patient and maternal interventions and outcomes between false-positive cases and normal controls, and (c) to determine the timing of clinical presentation of CoA. METHODS We performed a single-center, retrospective case control study of all fetuses with suspected isolated CoA who underwent both fetal echocardiographic evaluation and subsequent delivery at UCLA between January 1, 2011, and December 31, 2018. Maternal and neonatal medical records were reviewed for demographic and clinical data, for cases of suspected CoA and for controls. A separate review of our institution's surgical database was performed to identify characteristics of all patients (neonatal and pediatric) with isolated CoA who underwent surgical repair during the same time period. RESULTS Among the 50 fetal cases of isolated suspected CoA who delivered at our institution, 47 patients (94%) were found to be normal (false positives). Compared with normal controls, patients with suspected CoA were more likely to have delayed maternal bonding, delayed feeding, admission to the intensive care unit, performance of neonatal echocardiograms, initiation of intravenous fluids and initiation of prostaglandin E1, and a longer length of hospital stay. Among the 38 patients undergoing CoA repair at our institution during the study period, four patients were prenatally diagnosed and no patient presented clinically with symptoms before 48 hours after delivery. CONCLUSION Compared with normal controls, patients with prenatally suspected coarctation are more likely to have delayed maternal bonding, delayed feeding, more frequent neonatal echocardiograms, and longer length of hospital stay. Further refinement of neonatal management may improve postnatal care.
Collapse
Affiliation(s)
- Sannya V Hede
- Division of Pediatric Cardiology, UCLA Mattel Children's Hospital, David Geffen School of Medicine at UCLA, Los Angeles, California, USA
| | - Greggory DeVore
- Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, David Geffen School of Medicine at UCLA, Los Angeles, California, USA
| | - Gary Satou
- Division of Pediatric Cardiology, UCLA Mattel Children's Hospital, David Geffen School of Medicine at UCLA, Los Angeles, California, USA
| | - Mark Sklansky
- Division of Pediatric Cardiology, UCLA Mattel Children's Hospital, David Geffen School of Medicine at UCLA, Los Angeles, California, USA
| |
Collapse
|
48
|
Xiao AQ, Sun J, Zhu LH, Liao ZY, Shen P, Zhao LL, Latour JM. Effectiveness of intracavitary electrocardiogram-guided peripherally inserted central catheter tip placement in premature infants: a multicentre pre-post intervention study. Eur J Pediatr 2020; 179:439-446. [PMID: 31788740 DOI: 10.1007/s00431-019-03524-3] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/05/2019] [Revised: 10/28/2019] [Accepted: 11/03/2019] [Indexed: 12/19/2022]
Abstract
This pre-post intervention study was conducted in Neonatal Intensive Care Units in two Chinese hospitals. The objective was to evaluate the effectiveness and safety of intracavitary electrocardiogram (IC-ECG)-guided peripherally inserted central catheter (PICC) placement and tip positioning in premature infants. A total of 161 premature infants who required a PICC were enrolled and divided into two groups: pre-intervention group (n = 83) from October 2017 to July 2018 and post-intervention IC-ECG group (n = 78) from August 2018 to March 2019. Nurses were trained from May 2018 to July 2018. The reposition rate in the IC-ECG group and pre-interventions group was 3.85% and 19.28%, respectively (OR 5.970; 95% CI 1.666-21.395; p = 0.002). More infants achieved optimal tip position at the first attempt in the IC-ECG group than the pre-intervention group (93.59% vs 73.49%; OR 0.190; 95%CI 0.068-0.531; p = 0.001). The overall catheter-related complications in the pre-intervention group were 14.46% compared to 3.84% in the IC-ECG group (OR 2.962; 95%CI 1.013-8.661; p = 0.040). However, no significant differences were observed between the individual complication leakage, phlebitis and catheter-related blood stream infection.Conclusions: IC-ECG-guided peripherally inserted central catheter placement and tip positioning technology might decrease reposition rates, achieve more accurate tip positioning at the first attempt and might reduce catheter-related complications in premature infants. Further robust RCTs are needed to confirm the effectiveness of IC-ECG-guided PICC placement and tip positioning in neonates.What is Known:• Chest radiography is the gold standard for tip position confirmation of peripherally inserted central catheter placement.• Studies in adult patients have shown that electrocardiogram guidance in the placement of central venous catheters can be beneficial, while evidence in neonates is limited.What is New:• Intracavitary electrocardiogram-guided peripherally inserted central catheter placement might be superior to chest radiography in preterm infants.• Decreasing the repositioning rates and correct tip position of peripherally inserted central catheters might reduce catheter-related complications.
Collapse
Affiliation(s)
- Ai-Qing Xiao
- Division of Neonatal Medicine, Hunan Children's Hospital, Changsha, Hunan Province, China
| | - Jing Sun
- Nursing school, Hunan University of Chinese Medicine, Changsha, Hunan Province, China.,Nursing Department, Hunan Children's Hospital, Changsha, Hunan Province, China
| | - Li-Hui Zhu
- Nursing Department, Hunan Children's Hospital, Changsha, Hunan Province, China.
| | - Zhen-Yu Liao
- Division of Neonatal Medicine, Hunan Children's Hospital, Changsha, Hunan Province, China
| | - Ping Shen
- Division of Neonatal Medicine, Hunan Children's Hospital, Changsha, Hunan Province, China
| | - Lin-Lin Zhao
- Division of Neonatal Medicine, Xiangtan Central Hospital, Xiangtan, Hunan Province, China
| | - Jos M Latour
- Nursing Department, Hunan Children's Hospital, Changsha, Hunan Province, China.,School of Nursing and Midwifery, Faculty of Health and Human Sciences, University of Plymouth, Plymouth, UK
| |
Collapse
|
49
|
Incidence of peripheral intravenous catheter failure and complications in paediatric patients: Systematic review and meta analysis. Int J Nurs Stud 2020; 102:103488. [DOI: 10.1016/j.ijnurstu.2019.103488] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2019] [Revised: 10/28/2019] [Accepted: 11/18/2019] [Indexed: 11/22/2022]
|
50
|
Carr PJ, Rippey JCR, Cooke ML, Trevenen ML, Higgins NS, Foale AS, Rickard CM. Factors associated with peripheral intravenous cannulation first-time insertion success in the emergency department. A multicentre prospective cohort analysis of patient, clinician and product characteristics. BMJ Open 2019; 9:e022278. [PMID: 30944127 PMCID: PMC6500093 DOI: 10.1136/bmjopen-2018-022278] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
OBJECTIVES This study aimed to identify the incidence of and factors associated with peripheral intravenous catheter/cannula (PIVC) first time insertion success (FTIS) in the emergency department (ED). DESIGN Prospective cohort study. SETTING Two tertiary EDs in Western Australia. PARTICIPANTS 879 ED patients. PRIMARY OUTCOME To identify factors affecting FTIS using univariate and multivariate logistic regression modelling. We created four models: patient factors only; clinician factors only; products and technology factors only and all factors model. We assessed each model's performance using area under the receiver operating characteristic curve. RESULTS A total of 1201 PIVCs were inserted in 879 patients. The mean age was 60.3 (SD 22) years with slightly more females (52%). The FTIS rate was 73%, with 128 (15%) requiring a second attempt and 83 (9%) requiring three or more attempts. A small percentage (3%) had no recorded number of subsequent attempts. FTIS was related to the following patient factors: age (for a 1-year increase in age: OR 0.99, 95% CI 0.983 to 0.998; p=0.0097); and target vein palpability: (always palpable vs never palpable: OR 3.53 95% CI 1.64 to 7.60; only palpable with tourniquet vs never palpable: OR 2.20, 95% CI 1.06 to 4.57; p=0.0014). Clinician factors related to FTIS include: clinicians with greater confidence (p<0.0001) and insertion experience (301-1000 vs <301: OR 1.54, 95% CI 1.02 to 2.34; >1000 vs <301: OR 2.07, 95% CI 1.41 to 3.04; p=0.0011). The final all factors model combining patient factors; clinician factors and product and technology factors has greater discriminative ability than specific factors models. It has a sensitivity of 74.26%, specificity of 57.69%, positive predictive value of 82.87% and negative predictive value of 44.85%. CONCLUSION A clinical decision, matching patients who have no palpable veins and are older, with clinicians with greater confidence and experience, will likely improve FTIS. TRIALREGISTRATION NUMBER ANZCTRN12615000588594; Results.
Collapse
Affiliation(s)
- Peter J Carr
- Health Research Board, Clinical Research Facility, National University of Ireland, Galway, University Hospital Galway, Ireland, Galway, Ireland
- Emergency Medicine, School of Medicine, Faculty of Health and Medical Sciences, The University of Western Australia, Perth, Western Australia, Australia
- Alliance for Vascular Access Teaching and Research (AVATAR) Group, Menzies Health Institute Queensland, School of Nursing and Midwifery, Griffith University, Brisbane, Queensland, Australia
| | - James C R Rippey
- Emergency Medicine, School of Medicine, Faculty of Health and Medical Sciences, The University of Western Australia, Perth, Western Australia, Australia
- Alliance for Vascular Access Teaching and Research (AVATAR) Group, Menzies Health Institute Queensland, School of Nursing and Midwifery, Griffith University, Brisbane, Queensland, Australia
- Sir Charles Gairdner Hospital, QEII Medical Centre, Perth, Western Australia, Australia
| | - Marie L Cooke
- Alliance for Vascular Access Teaching and Research (AVATAR) Group, Menzies Health Institute Queensland, School of Nursing and Midwifery, Griffith University, Brisbane, Queensland, Australia
| | - Michelle L Trevenen
- Centre for Applied Statistics, University of Western Australia, Perth, Western Australia, Australia
| | - Niall S Higgins
- Alliance for Vascular Access Teaching and Research (AVATAR) Group, Menzies Health Institute Queensland, School of Nursing and Midwifery, Griffith University, Brisbane, Queensland, Australia
- The Royal Brisbane and Women's Hospital, Brisbane, Queensland, Australia
| | - Aileen S Foale
- Fiona Stanley Hospital, Murdoch, Western Australia, Australia
| | - Claire M Rickard
- Alliance for Vascular Access Teaching and Research (AVATAR) Group, Menzies Health Institute Queensland, School of Nursing and Midwifery, Griffith University, Brisbane, Queensland, Australia
- The Royal Brisbane and Women's Hospital, Brisbane, Queensland, Australia
| |
Collapse
|