Cho HM, Park KM, Jung TG, Park JY, Lee Y. Conventional versus helical blade screw insertion following the removal of the femoral head screw: a biomechanical evaluation using trochanteric gamma 3 locking nail versus PFN antirotation.
BMC Musculoskelet Disord 2021;
22:767. [PMID:
34496801 PMCID:
PMC8428115 DOI:
10.1186/s12891-021-04658-y]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/21/2020] [Accepted: 08/27/2021] [Indexed: 11/10/2022] Open
Abstract
OBJECTIVE
When a hip screw needs to be changed, choosing between the conventional (C-type) and helical blade (H-type) types is difficult. In this biomechanical study, we compared these two screw types relative to the type of the initial screw used.
METHODS
C- or H-type screws were inserted (leading screw) in three types of polyurethane bone models (Sawbone, Pacific Research Laboratories, Inc., Washington, USA: 130 × 180 × 40 mm) of different bone mineral densities (pounds per cubic feet [PCF] 5, 80 kg/m3; PCF 10, 160 kg/m3; and PCF 15, 240 kg/m3), and then successively or alternately inserted (following screw) after the leading screw removal. An original model (original C and H) of a leading screw without removal was created as a control. The strengths of resistance to pullout (PO) and rotational stress were measured. For each experimental condition, there were 30 experimental models.
RESULTS
The original C screw was superior in PO strength, and the original H-type screw was superior in rotational strength. When the C- or H-type screw was the leading screw, using the C-type screw again as the following screw (C1-C2, H1-C2) showed the greatest resistance to PO, and using the H-type screw as the following screw (C1-H2, H1-H2) showed superior resistance to rotational strength. However, the rotational strength of the C2 screw decreased by more than 50% compared with that of the original C screw. Moreover, the PO and rotational strengths of the H2 screw decreased to less than 30% overall compared with those of the original H screw.
CONCLUSION
The H-type screw should be used for second-time screw insertion procedures in cases where it is difficult to choose between PO and rotational strengths.
Collapse