1
|
Fidalgo-Pereira R, Carpio D, Torres O, Carvalho O, Silva F, Henriques B, Özcan M, Souza JCM. The influence of inorganic fillers on the light transmission through resin-matrix composites during the light-curing procedure: an integrative review. Clin Oral Investig 2022; 26:5575-5594. [PMID: 35767045 DOI: 10.1007/s00784-022-04589-5] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2022] [Accepted: 06/19/2022] [Indexed: 11/26/2022]
Abstract
PURPOSE The objective of this study was to perform an integrative review on the effect the inorganic fillers on the light transmission through the resin-matrix composites during the light-curing procedure. METHOD A bibliographic review was performed on PubMed using the following search terms: "fillers" OR "particle" AND "light curing" OR "polymerization" AND "light transmission" OR "light absorption" OR "light irradiance" OR "light attenuation" OR "light diffusion" AND "resin composite." The search involved articles published in English language in the last 10 years. RESULTS Selected studies reported a decrease in biaxial strength and hardness in traditional resin-matrix composites in function of the depth of polymerization. However, there were no significant differences in biaxial strength and hardness recorded along the polymerization depth of Bulk-Fill™ composites. Strength and hardness were enhanced by increasing the size and content of inorganic fillers although some studies revealed a progressive decrease in the degree of conversion on increasing silica particle size. The translucency of glass-ceramic spherical fillers promoted light diffusion mainly in critical situations such as in the case of deep proximal regions of resin-matrix composites. CONCLUSIONS The amount of light transmitted through the resin-matrix composites is influenced by the size, content, microstructure, and shape of the inorganic filler particles. The decrease of the degree of conversion affects negatively the physical and mechanical properties of the resin-matrix composites. CLINICAL RELEVANCE The type and content of inorganic fillers in the chemical composition of resin-matrix composites do affect their polymerization. As a consequence, the clinical performance of resin-matrix composites can be compromised leading to variable physical properties and degradation. The polymerization mode of resin-matrix composites can be improved according to the type of inorganic fillers in their chemical composition.
Collapse
Affiliation(s)
- Rita Fidalgo-Pereira
- University Institute of Health Sciences (IUCS), CESPU, 4585-116, Gandra, PRD, Portugal
| | - Daniela Carpio
- University Institute of Health Sciences (IUCS), CESPU, 4585-116, Gandra, PRD, Portugal
| | - Orlanda Torres
- University Institute of Health Sciences (IUCS), CESPU, 4585-116, Gandra, PRD, Portugal
| | - Oscar Carvalho
- Center for Microelectromechanical Systems (CMEMS-UMINHO), University of Minho, Campus Azurém, 4800-058, Guimarães, Portugal
- Associate Laboratory (LABBELS), University of Minho, 4710-057, Guimarães, Braga, Portugal
| | - Filipe Silva
- Center for Microelectromechanical Systems (CMEMS-UMINHO), University of Minho, Campus Azurém, 4800-058, Guimarães, Portugal
- Associate Laboratory (LABBELS), University of Minho, 4710-057, Guimarães, Braga, Portugal
| | - Bruno Henriques
- Center for Microelectromechanical Systems (CMEMS-UMINHO), University of Minho, Campus Azurém, 4800-058, Guimarães, Portugal
- Associate Laboratory (LABBELS), University of Minho, 4710-057, Guimarães, Braga, Portugal
- Ceramic and Composite Materials Research Group (CERMAT), Federal University of Santa Catarina (UFSC), Campus Trindade, Florianópolis, SC, 88040-900, Brazil
| | - Mutlu Özcan
- Dental Materials Unit, Center of Dental Medicine, Clinic of Reconstructive Dentistry, University of Zurich, 8032, Zurich, Switzerland
| | - Júlio C M Souza
- University Institute of Health Sciences (IUCS), CESPU, 4585-116, Gandra, PRD, Portugal.
- Center for Microelectromechanical Systems (CMEMS-UMINHO), University of Minho, Campus Azurém, 4800-058, Guimarães, Portugal.
- Associate Laboratory (LABBELS), University of Minho, 4710-057, Guimarães, Braga, Portugal.
| |
Collapse
|
2
|
Ardestani SS, Bonan RF, Mota MF, Farias RMDC, Menezes RR, Bonan PRF, Maciel PP, Ramos-Perez FMDM, Batista AUD, da Cruz Perez DE. Effect of the incorporation of silica blow spun nanofibers containing silver nanoparticles (SiO 2/Ag) on the mechanical, physicochemical, and biological properties of a low-viscosity bulk-fill composite resin. Dent Mater 2021; 37:1615-1629. [PMID: 34479726 DOI: 10.1016/j.dental.2021.08.012] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2021] [Revised: 08/14/2021] [Accepted: 08/17/2021] [Indexed: 11/16/2022]
Abstract
OBJECTIVE This work aimed at producing silica-blow-spun nanofibers containing silver nanoparticles (SiO2/Ag) and investigating the effect of their incorporation in different proportions, with or without pre-treatment with a silane coupling agent, on the mechanical, physicochemical, and biological properties of a commercial composite low-viscosity bulk-fill resin. METHODS The production of SiO2/Ag nanofibers was confirmed by transmission electron microscopy (TEM) and energy dispersive X-ray analysis (EDX). A portion of the produced nanofibers was silanized. Scanning electronic microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), contact angle measurements, and agar diffusion tests against Streptococcus mutans were used to verify the differences between silanized and non-silanized nanofibers. Different proportions (0.5 wt% and 1 wt%) of silanized (SiO2/Ag-0.5S and SiO2/Ag-1S) and non-silanized (SiO2/Ag-0.5NS and SiO2/Ag-1NS) nanofibers were incorporated into the bulk-fill composite (Opus Bulk Fill Flow, FGM). A commercial composite was used as the control. Evaluation of the color parameters (L*, a*, and b*), radiopacity, contact angle, antimicrobial activity, Vickers microhardness, surface roughness (Sa and Sq), flexural strength, and SEM of the fractured surfaces were performed. The data were analyzed using the Mann-Whitney U test (fiber morphology), Kruskal-Wallis tests, with Dunn's post hoc test (antimicrobial activity of the specimen against S. mutans), Student's t-test (disk diffusion), one-way ANOVA and Tukey (color, radiopacity, and contact angle), and two-way ANOVA and Tukey (microhardness, surface roughness, and flexural strength) tests. All statistical analyses were performed at a significance level of 1% (α = 0.01). RESULTS Porous nanometric SiO2/Ag fibers were successfully produced. The silanization process, confirmed by FTIR, increased the diameter and contact angle and reduced the growth inhibition halos of the nanofibers (p < 0.01). After the incorporation of nanofibers into the dental composite, all color parameters were altered in all the experimental groups (p < 0.01). All the groups presented adequate radiopacity values. No statistical difference was observed in the contact angles of the experimental composites (p > 0.01). The lowest microbial counts were obtained in the SiO2/Ag-0.5S group; although no significant difference was observed with the control group (p < 0.01). The SiO2/Ag-1S, SiO2/Ag-0.5S, and SiO2/Ag-0.5NS groups exhibited higher microhardness after 30 d of immersion in water (p < 0.01). The surface roughness (Sa-μm) resembled that of the control at baseline, except for the SiO2/Ag-1NS group. For the baseline evaluation of flexural strength, all the experimental groups exhibited lower values than the control, except for SiO2/Ag-0.5NS and SiO2/Ag-0.5S, but after 30 d of immersion in water, there was no difference (p < 0.01). SIGNIFICANCE The incorporation of 0.5% wt. of silanized nanofibers in the commercial composite (SiO2/Ag-0.5S) seemed to be promising, especially for its greater inhibition of S. mutans, adequate roughness, and flexural strength, in addition to high hardness, even after aging in water.
Collapse
Affiliation(s)
| | - Roberta Ferreti Bonan
- Universidade Federal de Pernambuco, School of Dentistry, Recife, Pernambuco, Brazil; Federal University of Paraiba, Department of Dentistry, João Pessoa, Paraiba, Brazil.
| | - Mariaugusta Ferreira Mota
- Federal University of Campina Grande, Department of Materials Engineering, Campina Grande, Paraiba, Brazil.
| | | | - Romualdo Rodrigues Menezes
- Federal University of Campina Grande, Department of Materials Engineering, Campina Grande, Paraiba, Brazil.
| | | | | | | | | | | |
Collapse
|
3
|
Shrinkage Stress and Temperature Variation in Resin Composites Cured via Different Photoactivation Methods: Insights for Standardisation of the Photopolymerisation. Polymers (Basel) 2021; 13:polym13132065. [PMID: 34201846 PMCID: PMC8272171 DOI: 10.3390/polym13132065] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2021] [Revised: 05/12/2021] [Accepted: 05/13/2021] [Indexed: 11/16/2022] Open
Abstract
The literature has shown that there is no consensus regarding the best resin composite photoactivation protocol. This study evaluated the efficiency of the conventional, soft-start, pulse-delay and exponential protocols for photoactivation of resin composites in reducing the shrinkage stress and temperature variation during the photopolymerisation. The photoactivation processes were performed using a photocuring unit and a smartphone app developed to control the irradiance according each photoactivation protocol. These photoactivation methods were evaluated applying photoactivation energies recommended by the resins manufactures. Three brands of resin composites were analysed: Z-250, Charisma and Ultrafill. The cure effectiveness was evaluated through depth of cure experiments. All results were statistically evaluated using one-way and multi-factor analysis of variance (ANOVA). The use of exponential and pulse-delay methods resulted in a significant reduction of the shrinkage stress for all evaluated resins; however, the pulse-delay method required too long a photoactivation time. The increases on the temperature were lower when the exponential photoactivation was applied; however, the temperature variation for all photoactivation protocols was not enough to cause damage in the restoration area. The evaluation of the depth of cure showed that all photoactivation protocols resulted in cured resins with equivalent hardness, indicating that the choice of an alternative photoactivation protocol did not harm the polymerisation. In this way, the results showed the exponential protocol as the best photoactivation technique for practical applications.
Collapse
|
4
|
Cardoso IO, Machado AC, Teixeira DNR, Basílio FC, Marletta A, Soares PV. Influence of Different Cordless Light-emitting-diode Units and Battery Levels on Chemical, Mechanical, and Physical Properties of Composite Resin. Oper Dent 2019; 45:377-386. [DOI: 10.2341/19-095-l] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/15/2019] [Indexed: 11/23/2022]
Abstract
Clinical Relevance
Irradiance may decrease as the light-emitting diode (LED) is discharged. Therefore, the LED must be charged carefully to prevent the possibility of influencing the chemical, mechanical, and physical properties of composite resin.
SUMMARY
The aim of this study was to evaluate the influence of different light-emitting diode (LED) curing units and battery levels on the chemical, mechanical, and physical properties of composite resins. The irradiance for each cycle from full to completely discharged battery level was evaluated, for five different new cordless LED units: Optilight Color (Gnatus), Bluephase (Ivoclar), Valo (Ultradent), Radii Plus (SDI), and Radii Xpert (SDI). After the irradiance evaluation, composite resin specimens were prepared and light cured, while varying the battery level for each LED unit: high level (HL, 100%), medium level (ML, 50%), and low level (LL, 10%). The degree of conversion, diametral tensile strength, sorption, and solubility were also evaluated. Data were checked for homoscedasticity and submitted to two-way and three-way analysis of variance, depending on the test performed, followed by the Tukey test with a significance level of 95%. A negative correlation was found between irradiance and cycles of light curing, which was checked by the Pearson correlation test. Valo and Radii Xpert were not influenced by the battery level in any test performed. However, different battery levels for some LED units can influence the degree of conversion, diametral tensile strength, sorption, and solubility of composite resins.
Collapse
|
5
|
Zhou X, Huang X, Li M, Peng X, Wang S, Zhou X, Cheng L. Development and status of resin composite as dental restorative materials. J Appl Polym Sci 2019. [DOI: 10.1002/app.48180] [Citation(s) in RCA: 63] [Impact Index Per Article: 12.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Affiliation(s)
- Xinxuan Zhou
- State Key Laboratory of Oral DiseasesSichuan University Chengdu 610041 Sichuan China
- National Clinical Research Center for Oral DiseasesSichuan University Chengdu 610041 Sichuan China
| | - Xiaoyu Huang
- State Key Laboratory of Oral DiseasesSichuan University Chengdu 610041 Sichuan China
- Department of Operative Dentistry and Endodontics, West China Hospital of StomatologySichuan University Chengdu 610041 Sichuan China
- National Clinical Research Center for Oral DiseasesSichuan University Chengdu 610041 Sichuan China
| | - Mingyun Li
- State Key Laboratory of Oral DiseasesSichuan University Chengdu 610041 Sichuan China
- National Clinical Research Center for Oral DiseasesSichuan University Chengdu 610041 Sichuan China
| | - Xian Peng
- State Key Laboratory of Oral DiseasesSichuan University Chengdu 610041 Sichuan China
- National Clinical Research Center for Oral DiseasesSichuan University Chengdu 610041 Sichuan China
| | - Suping Wang
- Department of Operative Dentistry and Endodontics & Stomatology CenterThe First Affiliated Hospital of Zhengzhou University Zhengzhou 540052 Henan China
| | - Xuedong Zhou
- State Key Laboratory of Oral DiseasesSichuan University Chengdu 610041 Sichuan China
- Department of Operative Dentistry and Endodontics, West China Hospital of StomatologySichuan University Chengdu 610041 Sichuan China
- National Clinical Research Center for Oral DiseasesSichuan University Chengdu 610041 Sichuan China
| | - Lei Cheng
- State Key Laboratory of Oral DiseasesSichuan University Chengdu 610041 Sichuan China
- Department of Operative Dentistry and Endodontics, West China Hospital of StomatologySichuan University Chengdu 610041 Sichuan China
- National Clinical Research Center for Oral DiseasesSichuan University Chengdu 610041 Sichuan China
| |
Collapse
|
6
|
Malarvizhi D, Karthick A, Gold Pearlin Mary NS, Venkatesh A. Shrinkage in composites: An enigma. J Int Oral Health 2019. [DOI: 10.4103/jioh.jioh_36_19] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
7
|
Effect of the Time of Salivary Contamination during Light Curing on Degree of Conversion and Microhardness of a Restorative Composite Resin. Biomimetics (Basel) 2018; 3:biomimetics3030023. [PMID: 31105245 PMCID: PMC6352669 DOI: 10.3390/biomimetics3030023] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2018] [Revised: 08/16/2018] [Accepted: 08/18/2018] [Indexed: 11/21/2022] Open
Abstract
Saliva contamination is a major clinical problem in restorative procedures. The purpose of this study was to evaluate the effect of the time of salivary contamination during light curing on the degree of conversion and the microhardness of a restorative composite resin. Eight groups of 10 samples for measuring the microhardness and eight groups of 5 samples for evaluating the degree of conversion were prepared. The samples of each group were contaminated with human saliva at a certain time. The first group (T0) was contaminated before light curing. The specimens in groups T2–T30 were contaminated at 2, 5, 10, 15, 20 and 30 s after the start of light curing, respectively. The samples of group T40 were contaminated after light curing. The degree of conversion and the microhardness of the specimens were measured by Fourier transform infrared (FTIR) spectroscopy and Vickers hardness testing techniques, respectively. The results of this study revealed that there were no significant differences between the groups in terms of the degree of conversion of the composite resin. Consistent with the findings for the degree of conversion, significant differences in the microhardness between the groups were not found. In conclusion, from a clinical point of view, the results of our study showed that the time of salivary contamination (before, during or after light curing of composite resin) has no significant effect on the polymerization (degree of conversion) and one of the important mechanical properties of dental composite resins (microhardness).
Collapse
|
8
|
Jain L, Mehta D, Meena N, Gupta R. Influence of Light Energy Density, Composite Type, Composite Thickness, and Postcuring Phase on Degree of Conversion of Bulk-fill Composites. Contemp Clin Dent 2018; 9:S147-S152. [PMID: 29962781 PMCID: PMC6006893 DOI: 10.4103/ccd.ccd_169_18] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Context: Achieving a high degree of conversion (DC) is one of the major concerns during photopolymerization of bulk-fill composites. Aims: To evaluate the effect of light energy densities (11.2 J/cm2 and 20 J/cm2) on the DC and variation of DC in the 24-h postcuring of four bulk-fill composites: SDR, Venus Bulk Fill, MI FIL, and Tetric N-Ceram Bulk Fill at simulated clinically relevant filling depths. Settings and Design: This was an in vitro comparative study. Subjects and Methods: A total of twenty samples were prepared using a teflon mold. VALO curing light was used with two light intensity modes of 1000 mW/cm2 for curing time of 20 s and 1400 mW/cm2 for curing time of 8 s. The energy density was calculated as follows: energy density (J/cm2) is the light intensity (mW/cm2) applied during a certain time (s) divided by 1000. The DC was measured at two time intervals: immediately postcure and after 24-h storage in artificial saliva using an Fourier-transform infrared spectroscopy equipped with attenuated total reflectance accessory. Statistical Analysis Used: ANOVA and Bonferroni test at P < 0.05. Results: High energy density (20 J/cm2) leads to higher DC. Thickness, type of composites, and postcuring phase strongly influence the DC. DC values of the top surface for all the bulk-fill materials investigated were found significantly greater (P < 0.005) than those of their bottom surface. Among composites, SDR showed highest DC. DC strongly increased after 24-h postcure by 32% on top surface and 76% on bottom surface. Conclusions: Energy density more than 20 J/cm2, derived by increasing curing time and low power density, helps obtain a high DC of bulk-fill composites for adequate clinical performance.
Collapse
Affiliation(s)
- Lipika Jain
- Department of Conservative Dentistry and Endodontics, Vokkaligara Sangha Dental College and Hospital, Bengaluru, Karnataka, India
| | - Deepak Mehta
- Department of Conservative Dentistry and Endodontics, Vokkaligara Sangha Dental College and Hospital, Bengaluru, Karnataka, India
| | - Naganath Meena
- Department of Conservative Dentistry and Endodontics, Vokkaligara Sangha Dental College and Hospital, Bengaluru, Karnataka, India
| | - Ravi Gupta
- Department of Conservative Dentistry and Endodontics, Faculty of Dentistry, Melaka Manipal Medical College, Manipal Academy of Higher Education, Manipal, Karnataka, India
| |
Collapse
|
9
|
Schneider AC, Mendonça MJ, Rodrigues RB, Busato PDMR, Camilotti V. Influência de três modos de fotopolimerização sobre a microdureza de três resinas compostas. POLIMEROS 2016. [DOI: 10.1590/0104-1428.1855] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Resumo A adequada fotopolimerização das resinas compostas é fundamental para obtenção de uma boa dureza capaz de resistir aos esforços mastigatórios. Assim, o objetivo deste estudo foi avaliar a influência das técnicas de fotopolimerização - Convencional (CONV), Soft-start (SS) e Pulso atrasado (PA) na microdureza Knoop de três resinas compostas. Para a confecção dos corpos-de-prova foram utilizadas as resinas compostas Filtek Z350 (3M ESPE), Empress Direct (IvoclarVivadent) e P90 (3M ESPE). Foram obtidos nove grupos experimentais em função da técnica de polimerização e resina composta. Vinte e quatro horas após a fotopolimerização foi realizado o teste de microdureza Knoop nas superfícies de base e topo de cada corpo-de-prova. Assim, os valores obtidos foram submetidos ao teste de Kruskall Wallis, seguido do teste de Dunn, p < 0,05. A eficácia da polimerização na superfície de topo das resinas compostas testadas não foi afetada pelos diferentes modos de polimerização. A resina composta Empress Direct apresentou os mais baixos valores de dureza para todos os modos de polimerização quando comparada às demais resinas compostas avaliadas.
Collapse
|
10
|
García-Contreras R, Scougall-Vilchis R, Acosta-Torres L, Arenas-Arrocena C, García-Garduño R, de la Fuente-Hernández J. Vickers microhardness comparison of 4 composite resins with different types of filler. JOURNAL OF ORAL RESEARCH 2015. [DOI: 10.17126/joralres.2015.061] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
|