Silva EJNL, Peña-Bengoa F, Ajuz NC, Vieira VTL, Martins JNR, Marques D, Pinto R, Rito Pereira M, Braz-Fernandes FM, Versiani MA. Multimethod analysis of large- and low-tapered single file reciprocating instruments: Design, metallurgy, mechanical performance, and irrigation flow. Int Endod J 2024; 57:601-616. [PMID: 38376108 DOI: 10.1111/iej.14047] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2023] [Revised: 02/03/2024] [Accepted: 02/05/2024] [Indexed: 02/21/2024]
Abstract
AIM To compare eight large- and low-tapered heat-treated reciprocating instruments regarding their design, metallurgy, mechanical properties, and irrigation flow through an in silico model. METHODOLOGY A total of 472 new 25-mm E-Flex Rex (25/.04 and 25/.06), Excalibur (25/.05), Procodile (25/.06), Reciproc Blue R25 (25/.08v), WaveOne Gold Primary (25/.07v), and Univy Sense (25/.04 and 25/.06) instruments were evaluated regarding their design (stereomicroscopy, scanning electron microscopy, and 3D surface scanning), metallurgy (energy-dispersive X-ray spectroscopy and differential scanning calorimetry), and mechanical performance (cyclic fatigue, torsional resistance, cutting ability, bending and buckling resistance). Computational fluid dynamics assessment was also conducted to determine the irrigation flow pattern, apical pressure, and wall shear stress in simulated canal preparations. Kruskal-Wallis and one-way anova post hoc Tukey tests were used for statistical comparisons (α = 5%). RESULTS Instruments presented variations in blade numbers, helical angles, and tip designs, with all featuring non-active tips, symmetrical blades, and equiatomic nickel-titanium ratios. Cross-sectional designs exhibited an S-shaped geometry, except for WaveOne Gold. Univy 25/.04 and Reciproc Blue displayed the smallest and largest core diameters at D3. Univy 25/.04 and E-Flex Rec 25/.04 demonstrated the longest time to fracture (p < .05). Reciproc Blue and Univy 25/.04 exhibited the highest and lowest torque to fracture, respectively (p < .05). Univy 25/.04 and Reciproc Blue had the highest rotation angles, whilst E-Flex Rec 25/.06 showed the lowest angle (p < .05). The better cutting ability was observed with E-Flex Rec 25/.06, Procodile, Excalibur, and Reciproc Blue (p > .05). Reciproc R25 and E-Flex Rec showed the highest buckling resistance values (p < .05), with WaveOne Gold being the least flexible instrument. The impact of instruments' size and taper on wall shear stress and apical pressure did not follow a distinct pattern, although Univy 25/.04 and E-Flex Rec 25/.06 yielded the highest and lowest values for both parameters, respectively. CONCLUSIONS Low-tapered reciprocating instruments exhibit increased flexibility, higher time to fracture, and greater angles of rotation, coupled with reduced maximum bending loads and buckling strength compared to large-tapered instruments. Nevertheless, low-tapered systems also exhibit lower maximum torque to fracture and inferior cutting ability, contributing to a narrower apical canal enlargement that may compromise the penetration of irrigants in that region.
Collapse
Affiliation(s)
- Emmanuel João Nogueira Leal Silva
- Department of Endodontics, School of Dentistry, State University of Rio de Janeiro (UERJ), Rio de Janeiro, RJ, Brazil
- Department of Endodontics, School of Dentistry, Grande Rio University (UNIGRANRIO), Rio de Janeiro, RJ, Brazil
| | - Fernando Peña-Bengoa
- Department of Endodontics, School of Dentistry, Universidad Andres Bello, Viña del Mar, Chile
| | - Natasha C Ajuz
- Department of Endodontics, School of Dentistry, Grande Rio University (UNIGRANRIO), Rio de Janeiro, RJ, Brazil
| | - Victor T L Vieira
- Department of Endodontics, School of Dentistry, Grande Rio University (UNIGRANRIO), Rio de Janeiro, RJ, Brazil
| | - Jorge N R Martins
- Faculdade de Medicina Dentária, Universidade de Lisboa, Lisboa, Portugal
- Grupo de Investigação em Bioquimica e Biologia Oral, Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), Faculdade de Medicina Dentária, Universidade de Lisboa, Lisboa, Portugal
- Centro de Estudo de Medicina Dentária Baseada na Evidência (CEMDBE) - Cochrane Portugal, Faculdade de Medicina Dentária, Universidade de Lisboa, Lisboa, Portugal
| | - Duarte Marques
- Faculdade de Medicina Dentária, Universidade de Lisboa, Lisboa, Portugal
- Grupo de Investigação em Bioquimica e Biologia Oral, Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), Faculdade de Medicina Dentária, Universidade de Lisboa, Lisboa, Portugal
- Centro de Estudo de Medicina Dentária Baseada na Evidência (CEMDBE) - Cochrane Portugal, Faculdade de Medicina Dentária, Universidade de Lisboa, Lisboa, Portugal
| | - Ricardo Pinto
- Faculdade de Medicina Dentária, Universidade de Lisboa, Lisboa, Portugal
- Grupo de Investigação em Bioquimica e Biologia Oral, Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), Faculdade de Medicina Dentária, Universidade de Lisboa, Lisboa, Portugal
| | - Mario Rito Pereira
- Faculdade de Medicina Dentária, Universidade de Lisboa, Lisboa, Portugal
| | - Francisco Manuel Braz-Fernandes
- CENIMAT/I3N, Department of Materials Science, NOVA School of Science and Technology, Universidade NOVA de Lisboa, Caparica, Portugal
| | - Marco A Versiani
- Oral Health Center, Brazilian Military Police, Minas Gerais, Brazil
| |
Collapse
|
2
|
Bürklein S, Maßmann P, Schäfer E, Donnermeyer D. Cyclic Fatigue of Different Reciprocating Endodontic Instruments Using Matching Artificial Root Canals at Body Temperature In Vitro. MATERIALS (BASEL, SWITZERLAND) 2024; 17:827. [PMID: 38399077 PMCID: PMC10890344 DOI: 10.3390/ma17040827] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/12/2024] [Revised: 02/05/2024] [Accepted: 02/07/2024] [Indexed: 02/25/2024]
Abstract
Reciprocating motion expands the lifetime of endodontic instruments during the preparation of severely curved root canals. This study aimed to investigate the time to fracture (TTF) and number of cycles to failure (NCF) of different reciprocating instruments (n = 20 in each group) at body temperature using a dynamic testing model (amplitude = 3 mm). Reciproc Blue (RPB), size 25/.08, WaveOne Gold (WOG) 25/.07, Procodile (Proc) 25/.06, R-Motion (RM_06) 25/.06 and R-Motion (RM_04) 30/.04 instruments were tested in their specific reciprocating motion in artificial matching root canals (size of the instrument ± 0.02 mm; angle of curvature 60°, radius 5.0 mm, and centre of curvature 5.0 mm from apical endpoint). The number of fractured instruments, TTF, NCF, the and lengths of the fractured instruments were recorded and statistically analysed using the Chi-Square or Kruskal-Wallis test. Both TTF (median 720, 643, 562, 406, 254 s) and the NCF (3600, 3215, 2810, 2032, 1482 cycles) decreased in the following order RM_06 > RPB > RM_04 > Proc > WOG with partially significant differences. During testing, only six RM_06 instruments fractured, whereas 16/20 (RPB), 18/20 (Proc), and 20/20 (RM_04, WOG) fractures were recorded (p < 0.05). Within the limitations of the present study, blue-coloured RPB and RM instruments exhibited a significantly superior cyclic fatigue resistance compared to SE-NiTi and Gold-wire instruments. Heat treatment, cross-sectional design and core mass significantly influenced the longevity of reciprocating instruments in cyclic dynamic testing.
Collapse
Affiliation(s)
- Sebastian Bürklein
- Central Interdisciplinary Ambulance in the School of Dentistry, University of Münster, 48149 Münster, Germany; (S.B.); (P.M.); (E.S.)
| | - Paul Maßmann
- Central Interdisciplinary Ambulance in the School of Dentistry, University of Münster, 48149 Münster, Germany; (S.B.); (P.M.); (E.S.)
| | - Edgar Schäfer
- Central Interdisciplinary Ambulance in the School of Dentistry, University of Münster, 48149 Münster, Germany; (S.B.); (P.M.); (E.S.)
| | - David Donnermeyer
- Department of Periodontology and Operative Dentistry, University of Münster, 48149 Münster, Germany
| |
Collapse
|
3
|
Zanza A, Reda R, Testarelli L. Endodontic Orthograde Retreatments: Challenges and Solutions. Clin Cosmet Investig Dent 2023; 15:245-265. [PMID: 37899987 PMCID: PMC10612510 DOI: 10.2147/ccide.s397835] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2023] [Accepted: 10/05/2023] [Indexed: 10/31/2023] Open
Abstract
Endodontic orthograde retreatments are considered one of the possible treatment options in case of post-treatment diseases considering the promising results present in the literature. Despite this, a plethora of articles have been published on this topic, and drawing conclusions could be challenging. For this reason, this review aims to summarize the crucial points on each aspect of non-surgical endodontic retreatments, discussing and comparing the current protocols, techniques, materials, and indications. Taking into consideration data from the literature, in terms of diagnosis, CBCT should be considered the first choice, since it can thoroughly affect the diagnosis and treatment plan. Regarding the procedural phases, some conclusions can be drawn: when present, coronal restoration materials such as crowns, partial prostheses, post, and core should be removed; the use of magnification devices, ultrasonic instruments, and an in-depth interpretation of radiographic images with both 2D and 3D images are strongly recommended during the orifice location; additional protocols such as irrigants activation, ultrasonic cleaning, and rotary or reciprocating instrumentation of treated canals are strongly recommended for filling materials removal and to achieve a high-quality chemo-mechanical disinfection; perforations should be treated as soon as possible, and the material of choice to treat them is the MTA or other calcium-silicate-based repair materials; the presence of ledges does not intrinsically reduce the success rate of RCRts if properly managed; in case of instrument fragments, their removal should be considered as the first treatment option, however many variables should be considered to select the proper technique or consider the option of bypassing.
Collapse
Affiliation(s)
- Alessio Zanza
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, Rome, Italy
| | - Rodolfo Reda
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, Rome, Italy
| | - Luca Testarelli
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, Rome, Italy
| |
Collapse
|
4
|
Silva EJNL, Martins JNR, Ajuz NC, Dos Santos Antunes H, Vieira VTL, Braz-Fernandes FM, Belladonna FG, Versiani MA. Design, metallurgy, mechanical properties, and shaping ability of 3 heat-treated reciprocating systems: a multimethod investigation. Clin Oral Investig 2023; 27:2427-2436. [PMID: 36749411 DOI: 10.1007/s00784-023-04899-2] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2022] [Accepted: 02/01/2023] [Indexed: 02/08/2023]
Abstract
OBJECTIVE This study aimed to compare 3 reciprocating systems regarding design, metallurgy, mechanical properties, and shaping ability. MATERIALS AND METHODS New Reciproc Blue R25, WaveOne Gold Primary, and REX 25 instruments (n=41 per group) were analyzed regarding design, metallurgy, and mechanical performance, while shaping ability (untouched canal walls, volume of removed dentin, and hard tissue debris) was tested in 36 anatomically matched root canals of mandibular molars. Results were compared using one-way ANOVA post hoc Tukey and Kruskal-Wallis tests with a significant level set at 5%. RESULTS All instruments showed symmetrical cross sections with asymmetrical blades, no radial lands, no major defects, and an almost equiatomic nickel and titanium ratio. The highest R-phase start temperatures were observed with WaveOne Gold (46.1°C) and REX (44.8°C), while Reciproc Blue had the lowest R-phase start (34.5°C) and finish (20°C) temperatures. WaveOne Gold had the lowest time to fracture (169 s) and the highest maximum load (301.6 gf) (P <0.05). The maximum torque of Reciproc Blue (2.2 N.cm) and WaveOne Gold (2.1 N.cm) were similar (P >0.05), but lower than REX (2.6 N.cm) (P <0.05). No statistical differences were observed among instruments in the angle of rotation (P >0.05) and in the shaping ability in both mesial and distal canals (P >0.05). CONCLUSION Although the overall design, temperature transition phases and mechanical behavior parameters were different among tested instruments, they were similar in terms of shaping ability. CLINICAL RELEVANCE All tested heat-treated NiTi reciprocating systems showed similar shaping ability, without clinically significant errors.
Collapse
Affiliation(s)
- Emmanuel J N L Silva
- Department of Endodontics, Grande Rio University (UNIGRANRIO), Rio de Janeiro, RJ, Brazil. .,Departament of Endodontics, Fluminense Federal University (UFF), Niterói, RJ, Brazil. .,Department of Endodontics, Rio de Janeiro State University (UERJ), Rio de Janeiro, RJ, Brazil.
| | - Jorge N R Martins
- Department of Endodontics, Faculdade de Medicina Dentária, Universidade de Lisboa, Lisbon, Portugal.,Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), Faculdade de Medicina Dentária, Universidade de Lisboa, Lisbon, Portugal.,Centro de Estudo de Medicina Dentária Baseada na Evidência (CEMDBE), Faculdade de Medicina Dentária, Universidade de Lisboa, Lisbon, Portugal
| | - Natasha C Ajuz
- Department of Endodontics, Grande Rio University (UNIGRANRIO), Rio de Janeiro, RJ, Brazil
| | | | | | - Francisco Manuel Braz-Fernandes
- CENIMAT/I3N, Department of Materials Science, NOVA School of Science and Technology, Universidade NOVA de Lisboa, Caparica, Portugal
| | | | | |
Collapse
|
5
|
Zaccaro-Scelza MF, Martinez RLCH, Tavares SO, Gonçalves FP, Montagnana M, Silva EJNLD, Scelza P. Noncontact 3D evaluation of surface topography of reciprocating instruments after retreatment procedures. Braz Dent J 2022; 33:38-46. [PMID: 35766715 PMCID: PMC9645204 DOI: 10.1590/0103-6440202204876] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2022] [Accepted: 03/08/2022] [Indexed: 12/03/2022] Open
Abstract
This study evaluated the Reciproc R25 and Pro-R 25 instruments in unused
condition, after one and a second use in endodontic retreatment employing a
noncontact 3D light interferometer profiler, scanning electron microscopy (SEM)
and cyclic fatigue tests. Twenty single-root teeth were instrumented with
Reciproc R25 and filled with gutta-percha and sealer. A 3D profiler with a 20x
objective using the Mx™ software was used to evaluate the cutting blade surfaces
of Reciproc R25 and Pro-R 25 (n=5 per group) in unused condition, after the
first and second uses in retreatment procedures. After retreatment, SEM was used
to evaluate the topographic features of the used instruments. Cyclic fatigue
tests were performed to compare new to used instruments. One-way ANOVA followed
by Tukey test was used to compare the tested instruments before and after the
first and second uses. Student t-test was used to compare the different
instruments and for cyclic fatigue evaluation. No significant differences were
observed in the cutting blade surfaces of Reciproc and Pro-R before and after
one and two uses (p>0.05). Reciproc without use showed higher Sa and Sq when
compared to Pro-R without use (p<0.05). No differences were observed between
Reciproc and Pro-R after one and two uses (p>0.05). New and unused Reciproc
showed longer time to fracture than Pro-R instruments (p<0.05), and only
Pro-R showed differences between new and used instruments (p<0.05).
Retreatment procedures with Reciproc and Pro-R did not change the surface
topography of instruments. Reciproc had greater resistance to cyclic fatigue
compared with Pro-R.