Tidd JL, Gudapati LS, Simmons HL, Klika AK, Pasqualini I, Piuzzi NS. Do Patients With Hypoallergenic Total Knee Arthroplasty Implants for Metal Allergy Do Worse? An Analysis of Health Care Utilizations and Patient-Reported Outcome Measures.
J Arthroplasty 2024;
39:103-110. [PMID:
37454947 DOI:
10.1016/j.arth.2023.07.005]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/26/2023] [Revised: 07/02/2023] [Accepted: 07/10/2023] [Indexed: 07/18/2023] Open
Abstract
BACKGROUND
Metal allergy is a rare and controversial cause of implant failure and poor outcomes following total knee arthroplasty (TKA). Few studies have investigated clinical and patient-reported outcome measures (PROMs) in patients treated with hypoallergenic implants. This investigation aimed to compare: (1) health care utilizations (eg, hospital length of stay, 90-day readmission rate, and incidence of nonhome discharge) and (2) 1-year PROMs between patients who received hypoallergenic and standard TKA implants.
METHODS
This was a retrospective review of prospectively collected data from patients who underwent primary TKA between 2018 and 2019. Propensity score matching (3:1) was used to compare standard TKA patients with those who received hypoallergenic TKA implants, respectively. Knee injury and Osteoarthritis Outcome Score (KOOS) pain, KOOS Physical function Shortform (PS), and Veterans RAND 12-Item Health Survey Mental Component Score were collected preoperatively and at 1-year. After matching, 190 hypoallergenic and 570 standard TKAs were analyzed.
RESULTS
No differences were observed in length of stay (P = .98), 90-day readmission (P = .89), and nonhome discharge (P = .82). Additionally, there was no significant difference in change from preoperative to 1-year PROMs (KOOS pain, P = .97; KOOS PS, P = .88; Veterans RAND 12-Item Health Survey Mental Component Score, P = .28). Patient-reported satisfaction was similar at 1-year (P = .23). Patients achieved similar rates of Patient Acceptable Symptom State (PASS) and minimal clinically important difference (MCID) for KOOS pain (PASS, P = .77; MCID, P = .33) and KOOS PS (PASS, P = .44; MCID, P = .65).
CONCLUSION
Patients treated with hypoallergenic TKA implants for suspected metal allergy had similar outcomes compared to patients who had standard implants and no metal allergy.
Collapse