1
|
Sirignano M, Nyland J, Krupp R. Subacromial balloon spacer massive rotator cuff tear treatment systematic review and meta-analysis: Patient selection and physical therapy may be keys to outcome success. Knee Surg Sports Traumatol Arthrosc 2024; 32:2346-2357. [PMID: 38922784 DOI: 10.1002/ksa.12331] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/27/2024] [Revised: 06/10/2024] [Accepted: 06/11/2024] [Indexed: 06/28/2024]
Abstract
PURPOSE Subacromial balloon spacer implantation (SBSI) efficacy for massive rotator cuff tear treatment was evaluated based on perceived shoulder function, active shoulder mobility, pain, complications and research study methodological quality. The purpose was to better discern the efficacy of this device from both surgical and rehabilitative perspectives to improve patient outcomes. METHODS PubMed, EMBASE and Cochrane Library databases were searched (1 January 2010 to 1 June 2024) using 'balloon spacer', 'subacromial spacer', 'subacromial balloon spacer', 'shoulder spacer' and 'inspace' terms. Pre-surgery (baseline), 12-month (12-m) and 24-month (24-m) post-SBSI mean changes were compared using one-way ANOVA and Scheffe post hoc tests, and comparative study effect sizes were calculated (p ≤ 0.05). RESULTS This review consists of 27 studies with 894 patients (67.8 ± 5 years of age) and 29.4 ± 17-month follow-up. Modified Coleman Methodology Scores (MCMS) revealed fair overall quality (mean = 61.4 ± 11). Constant-Murley scores improved from 34.8 ± 6 (baseline), to 64.2 ± 9 (12-m) and 67.9 ± 8 (24-m) (12-m, 24-m > baseline, p < 0.001). ASES scores improved from 35.1 ± 14 (baseline), to 83.3 ± 7 (12-m) and 81.8 ± 5 (24-m)(12-m, 24-m > baseline, p < 0.001). VAS pain scores improved from 6.6 ± 1 (baseline), to 2.6 ± 1 (12-m) and 2.0 ± 1 (24-m) (12-m, 24-m < baseline, p < 0.001). Flexion increased from 108.5 ± 25° (baseline), to 128.5 ± 30° (12-m) and 151.2 ± 14° (24-m) (24-m > 12-m, baseline, p = 0.01). Abduction increased from 97.7 ± 24° (baseline) to 116.3 ± 23° (12-m) and 142.3 ± 15° (24-m) (24-m > 12-m, baseline, p = 0.02). External rotation (ER) in adduction changed from 33.1 ± 7° (baseline) to 32.5 ± 4° (12-m) and 53.9 ± 9° (24-m)(24-m > 12-m, baseline, p = 0.01). ER at 90° abduction increased from 56.3 ± 3° (baseline) to 83.5 ± 5° (12-m) and 77.1 ± 4° (24-m) (24-m, 12-m > baseline, p = 0.01). Comparison studies, however, displayed insignificant results with small effect sizes. CONCLUSION Despite overall fair MCMS scores, at 24-m post-SBSI, shoulder function improved and pain decreased. More rigorous comparative studies, however, revealed insignificant findings. Patients with the potential to re-establish the essential glenohumeral joint force couple that depresses the humeral head on the glenoid fossa and who comply with physical therapy may be more likely to achieve success following SBSI. LEVEL OF EVIDENCE Level IV.
Collapse
Affiliation(s)
- Michael Sirignano
- Department of Orthopaedic Surgery, University of Louisville, Louisville, Kentucky, USA
| | - John Nyland
- Department of Orthopaedic Surgery, University of Louisville, Louisville, Kentucky, USA
- Norton Orthopaedic Institute, Louisville, Kentucky, USA
| | - Ryan Krupp
- Department of Orthopaedic Surgery, University of Louisville, Louisville, Kentucky, USA
- Norton Orthopaedic Institute, Louisville, Kentucky, USA
| |
Collapse
|
2
|
Levy KH, White CA, Pujari A, Patel AV, Kator JL, Parsons BO, Galatz LM, Cagle PJ. Subacromial Balloon Spacer Implantation Is a Promising Alternative for Patients With Massive Irreparable Rotator Cuff Tears: A Systematic Review. Arthroscopy 2024; 40:162-173.e2. [PMID: 37355186 DOI: 10.1016/j.arthro.2023.05.028] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/06/2023] [Revised: 05/20/2023] [Accepted: 05/29/2023] [Indexed: 06/26/2023]
Abstract
PURPOSE To provide an overview of the existing literature on subacromial balloon spacers for the treatment of massive irreparable rotator cuff tears, in an effort to inform surgeons of the procedure's clinical effectiveness. METHODS The PubMed, Scopus, and Ovid EMBASE databases were queried to identify studies evaluating the clinical, radiographic, and patient-reported outcomes of patients indicated for subacromial balloon spacer implantation. The following datapoints were extracted: study demographics, patient baseline characteristics, and postoperative outcomes of interest. Outcomes were evaluated at baseline and at the longest available follow-up period. RESULTS A total 766 patients were included among 22 included studies, with an average follow-up of 27.54 months. Improvements were seen for all clinical and patient-reported outcomes: forward elevation (ranging from 9.20 to 90.00° improvement), external rotation (ranging from 2.00 to 22.00°), abduction (ranging from 14.00 to 95.00°), Total Constant Score (ranging from 7.70 to 50.00), American Shoulder and Elbow Surgeons score (ranging from 24.60 to 59.84), Oxford Shoulder Score (ranging from 7.20 to 22.20), and pain score (ranging from 3.57 to 6.50). Minimal differences were seen in acromiohumeral interval (ranging from -2.00 to 1.27). Reoperation and complication rates ranged from 0% to 33% and 0% to 19.64%, respectively. CONCLUSIONS The short-term results of subacromial balloon spacers for management of massive rotator cuff tears demonstrate clinically relevant improvements in shoulder range of motion and substantial improvements in patient-reported outcome measures. Of note, minimal change in acromiohumeral interval was seen on postoperative radiography, and wide variations in complication and reoperation rates were reported across studies. LEVEL OF EVIDENCE Level IV, systematic review of Level I-IV studies.
Collapse
Affiliation(s)
- Kenneth H Levy
- Department of Orthopedic Surgery, Icahn School of Medicine at Mount Sinai, New York City, New York, U.S.A
| | - Christopher A White
- Department of Orthopedic Surgery, Icahn School of Medicine at Mount Sinai, New York City, New York, U.S.A
| | - Amit Pujari
- Department of Orthopedic Surgery, Icahn School of Medicine at Mount Sinai, New York City, New York, U.S.A
| | - Akshar V Patel
- Department of Orthopedic Surgery, Icahn School of Medicine at Mount Sinai, New York City, New York, U.S.A
| | - Jamie L Kator
- Department of Orthopedic Surgery, Icahn School of Medicine at Mount Sinai, New York City, New York, U.S.A
| | - Bradford O Parsons
- Department of Orthopedic Surgery, Icahn School of Medicine at Mount Sinai, New York City, New York, U.S.A
| | - Leesa M Galatz
- Department of Orthopedic Surgery, Icahn School of Medicine at Mount Sinai, New York City, New York, U.S.A
| | - Paul J Cagle
- Department of Orthopedic Surgery, Icahn School of Medicine at Mount Sinai, New York City, New York, U.S.A..
| |
Collapse
|
3
|
Berk AN, Cregar WM, Gachigi KK, Trofa DP, Schiffern SC, Hamid N, Rao AJ, Saltzman BM. Outcomes of subacromial balloon spacer implantation for irreparable rotator cuff tears: a systematic review and meta-analysis. J Shoulder Elbow Surg 2023; 32:2180-2191. [PMID: 37247776 DOI: 10.1016/j.jse.2023.04.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Revised: 04/02/2023] [Accepted: 04/12/2023] [Indexed: 05/31/2023]
Abstract
BACKGROUND The management of irreparable rotator cuff tears remains a topic of considerable debate among orthopedic surgeons. Currently, there is little consensus regarding the gold-standard treatment; however, an emerging option involves the use of a biodegradable subacromial spacer. The purpose of this study, therefore, was to systematically review and synthesize the current literature reporting on the clinical outcomes following implantation of a subacromial balloon spacer (SABS) for the treatment of patients with irreparable rotator cuff tears. METHODS A systematic review of the PubMed Central, MEDLINE, Embase, Scopus, and Cochrane Library databases from inception through December 2022 was performed. Clinical outcome studies reporting on functional and clinical outcomes, as well as postoperative complications, were included. RESULTS A total of 127 studies were initially identified, of which 28 were deemed eligible for inclusion in our review. Of these studies, 17 reported adequate preoperative and postoperative data (mean and a measure of variance) and thus were included in the meta-analysis. Among the included studies, a total of 894 shoulders (886 patients) were included; the mean age was 67.4 years (range, 61.7-76.2 years). The average follow-up period was 30.4 months (range, 12-56 months). All postoperative patient-reported outcomes improved significantly from baseline, including the Constant score (mean difference, 33.53; P < .001), American Shoulder and Elbow Surgeons score (mean difference, 40.38; P < .001), Oxford Shoulder Score (mean difference, 12.05; P = .004), and visual analog scale pain score or Numeric Pain Rating Scale score (mean difference, -3.79; P < .001). Forward elevation (mean difference, 24°; P < .001), abduction (mean difference, 52°; P = .02), and external rotation (mean difference, 15°; P < .001) improved. Device-related complications occurred at a rate of 3.6%, the most common of which were balloon migration (1.0%) and synovitis (0.6%). Ultimately, 5% of patients required salvage reverse shoulder arthroplasty. CONCLUSION Short-term outcomes suggest that SABS implantation can be a safe and effective treatment and appears to be associated with early improvements in postoperative pain and function. Clinical heterogeneity, use of concomitant procedures, and variations in patient selection limit our ability to conclusively interpret the available evidence. We do not yet know the potential therapeutic value of SABS implantation relative to other currently accepted treatment strategies, the length of symptomatic improvement that can be expected, or the long-term implications of SABS use on the outcomes of further salvage procedures.
Collapse
Affiliation(s)
- Alexander N Berk
- OrthoCarolina Sports Medicine Center, Charlotte, NC, USA; OrthoCarolina Research Institute, Charlotte, NC, USA; Atrium Health Musculoskeletal Institute, Charlotte, NC, USA
| | - William M Cregar
- OrthoCarolina Sports Medicine Center, Charlotte, NC, USA; OrthoCarolina Research Institute, Charlotte, NC, USA; Atrium Health Musculoskeletal Institute, Charlotte, NC, USA
| | | | - David P Trofa
- Department of Orthopaedics, NewYork-Presbyterian/Columbia University Irving Medical Center, New York, NY, USA
| | - Shadley C Schiffern
- OrthoCarolina Sports Medicine Center, Charlotte, NC, USA; OrthoCarolina Research Institute, Charlotte, NC, USA; Atrium Health Musculoskeletal Institute, Charlotte, NC, USA
| | - Nady Hamid
- OrthoCarolina Sports Medicine Center, Charlotte, NC, USA; OrthoCarolina Research Institute, Charlotte, NC, USA; Atrium Health Musculoskeletal Institute, Charlotte, NC, USA
| | - Allison J Rao
- Department of Orthopedic Surgery, University of Minnesota Physicians, University of Minnesota, Minneapolis, MN, USA
| | - Bryan M Saltzman
- OrthoCarolina Sports Medicine Center, Charlotte, NC, USA; OrthoCarolina Research Institute, Charlotte, NC, USA; Atrium Health Musculoskeletal Institute, Charlotte, NC, USA.
| |
Collapse
|
4
|
Bents EJ, Bents RT. Ultrasound-Guided Deflation and Arthroscopic Removal of a Migrated Subacromial Balloon Spacer. Arthrosc Tech 2023; 12:e1601-e1606. [PMID: 37780658 PMCID: PMC10533858 DOI: 10.1016/j.eats.2023.05.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/08/2023] [Accepted: 05/08/2023] [Indexed: 10/03/2023] Open
Abstract
Full-thickness massive irreparable rotator cuff tears present a demanding challenge for the surgeon. The subacromial balloon spacer is a novel biodegradable implant used to treat massive, irreparable rotator cuff tears. There have, however, been several isolated reports of balloon migration. This Technical Note describes ultrasound-assisted balloon deflation followed by arthroscopic removal of a symptomatic dislodged balloon.
Collapse
|
5
|
McNamara JK, Sudah SY, Manzi JE, Constantinescu DS, Nicholson AD, Menendez ME. Subacromial balloon spacers for the treatment of irreparable rotator cuff tears: a review. JSES REVIEWS, REPORTS, AND TECHNIQUES 2023; 3:331-335. [PMID: 37588486 PMCID: PMC10426637 DOI: 10.1016/j.xrrt.2023.01.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/06/2023]
Abstract
Massive irreparable rotator cuff tears (RCTs) are a commonly encountered orthopedic condition that can be difficult to treat. Several techniques have been described to manage these tears, with the implantable subacromial balloon spacer being one of the most recent. The device, which has only been approved for clinical use in the United States since 2021, functions by resisting the superior humeral head migration seen in the setting of massive RCTs and restoring normal shoulder biomechanics, as corroborated by cadaveric studies. However, results regarding clinical outcomes have been mixed to date, and further high-quality studies are needed to define the optimal use of the subacromial balloon spacer in the treatment of massive irreparable RCTs.
Collapse
Affiliation(s)
- John K. McNamara
- Department of Orthopaedic Surgery, Rutgers Robert Wood Johnson Medical School New Brunswick, NJ, USA
| | - Suleiman Y. Sudah
- Department of Orthopedic Surgery, Monmouth Medical Center Long Branch, NJ, USA
| | - Joseph E. Manzi
- Department of Orthopedic Surgery, Lenox Hill Hospital, Northwell Health, New York, NY, USA
| | - David S. Constantinescu
- Department of Orthopedic Surgery, University of Miami Miller School of Medicine, Miami, FL, USA
| | | | | |
Collapse
|
6
|
Fury MS, Cirino CM, White AE, Bauer TW, Taylor SA. Rice-Body Synovitis, Foreign Body Reaction, and Rotator Cuff Failure After Subacromial Balloon Spacer Augmentation of a Rotator Cuff Repair: A Case Report. JBJS Case Connect 2023; 13:01709767-202306000-00040. [PMID: 37235697 DOI: 10.2106/jbjs.cc.23.00009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
CASE A 66-year-old woman presented with shoulder pain and weakness 4 months after augmentation of a rotator cuff repair with a Stryker InSpace subacromial balloon spacer. A magnetic resonance imaging (MRI) demonstrated a failed rotator cuff repair, large effusion with rice bodies, synovitis, axillary lymphadenopathy, loose anchors, and erosive changes to the greater tuberosity. Arthroscopy revealed balloon fragmentation surrounded by diffusely hyperemic synovium without repairable cuff tissue. Final cultures proved negative for infection. Histologic evaluation revealed ulcerated synovium with diffuse chronic and focal acute inflammation. CONCLUSION Despite promising early results, augmentation of a rotator cuff repair with a subacromial balloon spacer introduces a risk of inflammatory reaction that may mimic a deep infection and compromise rotator cuff healing.
Collapse
Affiliation(s)
- Matthew S Fury
- Department of Sports Medicine and Shoulder Surgery, Hospital for Special Surgery, New York, New York
| | - Carl M Cirino
- Department of Sports Medicine and Shoulder Surgery, Hospital for Special Surgery, New York, New York
| | - Alex E White
- Department of Sports Medicine and Shoulder Surgery, Hospital for Special Surgery, New York, New York
| | - Thomas W Bauer
- Department of Pathology and Laboratory Medicine, Hospital for Special Surgery, New York, New York
| | - Samuel A Taylor
- Department of Sports Medicine and Shoulder Surgery, Hospital for Special Surgery, New York, New York
| |
Collapse
|
7
|
Interpositional Balloon: A New Frontier. OPER TECHN SPORT MED 2023. [DOI: 10.1016/j.otsm.2023.150983] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
|
8
|
Lubowitz JH, Brand JC, Rossi MJ. Early Treatment of Shoulder Pathology Is Necessary but Not Enough Is Being Performed. Arthroscopy 2022; 38:2943-2953. [PMID: 36344053 DOI: 10.1016/j.arthro.2022.08.031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/29/2022] [Accepted: 08/29/2022] [Indexed: 11/06/2022]
Abstract
Delayed treatment of shoulder instability results in bone loss requiring more-complicated surgery, in turn resulting in less-optimal outcomes. Similarly, delayed treatment of repairable rotator cuff tears results in irreparable tears requiring more-complicated surgery and resulting in less-optimal outcomes. Delayed treatment of shoulder pathology is a problem. Solutions include education and research investigation.
Collapse
|