Seeman T, Staněk K, Slížek J, Filipovský J, Feber J. Unattended automated office blood pressure measurement in children.
Blood Press 2021;
30:359-366. [PMID:
34565278 DOI:
10.1080/08037051.2021.1963666]
[Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/09/2023]
Abstract
PURPOSE
We studied the performance of unattended automated office blood pressure (uAOBP) measurement in children, in relation to oscillometric office BP (OBP) and ambulatory blood pressure monitoring (ABPM).
MATERIALS AND METHODS
One hundred and eleven stable treated and untreated outpatients investigated for hypertension underwent uAOBP measurements (seated unattended in a quiet room separate from the renal clinic room, six times after a 5 min rest with the BpTRU device), and immediately before using the oscillometric device. Ambulatory 24 h blood pressure monitoring (ABPM) was performed on the same day in a subgroup of 42 children.
RESULTS
UAOBP measurements were successful in 106 children (95%), 5 pre-school children did not tolerate to be alone in the room. The mean ± SD systolic/diastolic uAOBP, OBP and daytime ABP were 109.1 ± 14.0/70.8 ± 10.7 mmHg, 121.6 ± 16.5/77.6 ± 10.5 mmHg and 123.5 ± 11.3/73.7 ± 6.8 mmHg, respectively. Systolic/diastolic uAOBP was significantly lower than OBP by 13.6/7.6 mmHg (p < 0.0001) and lower than daytime ABP by 14.4 ± 0.5/2.9 ± 0.3 mmHg (p < 0.0001). The heart rate was not significantly different during uAOBP than during OBP measurements. On Bland Altman analysis the uAOBP underestimated OBP by a mean of 15.6 mmHg for systolic BP and by 8.6 mmHg for diastolic BP. In all 9 children with white-coat systolic hypertension uAOBP was within the normal range (<95th pc for OBP), in six of nine children with white-coat diastolic hypertension uAOBP was within the normal range however, in three of them it was elevated despite normal ABP.
CONCLUSION
uAOBP measurement is feasible in school-aged children, its values are considerably lower than OBP as well as daytime ABP and it could help with detection of white-coat systolic hypertension. The clinical applicability of uAOBP in children should be confirmed in further studies.