1
|
Improved Outcomes for Infants and Young Children Undergoing Lung Transplantation at Three Years of Age and Younger. Ann Am Thorac Soc 2023; 20:254-261. [PMID: 36260085 DOI: 10.1513/annalsats.202202-093oc] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023] Open
Abstract
Rationale: Since its inception, older children and adolescents have predominated in pediatric lung transplantation. Most pediatric lung transplant programs around the world have transplanted few infants and young children. Early mortality after lung transplantation and inadequate donor organs have been perceived as limitations for success in lung transplantation at this age. Objectives: Our aim was to describe our experience in a large pediatric lung transplant program with respect to lung transplantation in infants and young children, focusing on diagnosis, waitlist, and mortality. Methods: We performed a retrospective review of infants and young children under 3 years of age at the time of transplant in our program from 2002 through 2020. Results: The patient cohort represented a severely morbid recipient group, with the majority hospitalized in the intensive care unit on mechanical ventilation just before transplantation. There was a marked heterogeneity of diagnoses distinct from diagnoses in an older cohort. Waitlist time was shorter than in older age cohorts. There was a decrease in early mortality, lower incidence of allograft rejection, and satisfactory long-term survival in this age group compared with the older cohort and published experience. Severe viral infection was an important cause of early mortality after transplant. Nonetheless, survival is comparable to older patients, with better enduring survival in those who survive the early transplant period in more recent years. Conclusions: Carefully selected infants and young children with end-stage lung and pulmonary vascular disease are appropriate candidates for lung transplantation and are likely underserved by current clinical practice.
Collapse
|
2
|
Chiel LE, Winthrop ZA, Fynn-Thompson F, Midyat L. Extracorporeal membrane oxygenation and paracorporeal lung assist devices as a bridge to pediatric lung transplantation. Pediatr Transplant 2022; 26:e14289. [PMID: 35416395 DOI: 10.1111/petr.14289] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/04/2022] [Revised: 03/31/2022] [Accepted: 04/03/2022] [Indexed: 01/16/2023]
Abstract
BACKGROUND "Bridging" is a term used to describe the implementation of various treatment modalities to improve waitlist survival while a patient awaits lung transplantation. ECMO and PLAD are technologies used to bridge patients to lung transplantation. ECMO and PLAD are cardiopulmonary support systems that help move blood forward while using an artificial membrane to remove CO2 from and add O2 to the blood. Recent studies showed that these technologies are increasingly effective in bridging patients to lung transplantation, especially with optimizing patient selection, implementing physical rehabilitation and ambulation goals, standardization of management decisions, and increasing staff experience, among other considerations. We review these technologies, their roles as bridges to pediatric lung transplantation, as well as indications, contraindications, complications, and mortality rates. CONCLUSION Finally, we discuss the existing knowledge gaps and areas for future research to improve patient outcomes and understanding of lung assist devices.
Collapse
Affiliation(s)
- Laura E Chiel
- Division of Pulmonary Medicine, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Zachary A Winthrop
- Department of Pediatrics, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Francis Fynn-Thompson
- Department of Cardiac Surgery, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Levent Midyat
- Division of Pulmonary Medicine, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| |
Collapse
|
3
|
Steuer NB, Hugenroth K, Beck T, Spillner J, Kopp R, Reinartz S, Schmitz-Rode T, Steinseifer U, Wagner G, Arens J. Long-Term Venovenous Connection for Extracorporeal Carbon Dioxide Removal (ECCO 2R)-Numerical Investigation of the Connection to the Common Iliac Veins. Cardiovasc Eng Technol 2020; 11:362-380. [PMID: 32405926 PMCID: PMC7385029 DOI: 10.1007/s13239-020-00466-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/18/2019] [Accepted: 05/02/2020] [Indexed: 02/06/2023]
Abstract
Purpose Currently used cannulae for extracorporeal carbon dioxide removal (ECCO2R) are associated with complications such as thrombosis and distal limb ischemia, especially for long-term use. We hypothesize that the risk of these complications is reducible by attaching hemodynamically optimized grafts to the patient’s vessels. In this study, as a first step towards a long-term stable ECCO2R connection, we investigated the feasibility of a venovenous connection to the common iliac veins. To ensure its applicability, the drainage of reinfused blood (recirculation) and high wall shear stress (WSS) must be avoided. Methods A reference model was selected for computational fluid dynamics, on the basis of the analysis of imaging data. Initially, a sensitivity analysis regarding recirculation was conducted using as variables: blood flow, the distance of drainage and return to the iliocaval junction, as well as the diameter and position of the grafts. Subsequently, the connection was optimized regarding recirculation and the WSS was evaluated. We validated the simulations in a silicone model traversed by dyed fluid. Results The simulations were in good agreement with the validation measurements (mean deviation 1.64%). The recirculation ranged from 32.1 to 0%. The maximum WSS did not exceed 5.57 Pa. The position and diameter of the return graft show the highest influence on recirculation. A correlation was ascertained between recirculation and WSS. Overall, an inflow jet directed at a vessel wall entails not only high WSS, but also a flow separation and thereby an increased recirculation. Therefore, return grafts aligned to the vena cava are crucial. Conclusion In conclusion, a connection without recirculation could be feasible and therefore provides a promising option for a long-term ECCO2R connection.
Collapse
Affiliation(s)
- N B Steuer
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany.
| | - K Hugenroth
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - T Beck
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - J Spillner
- Clinic for Cardiothoracic Surgery, University Hospital RWTH Aachen, Aachen, Germany
| | - R Kopp
- Department of Anesthesiology, University Hospital RWTH Aachen, Aachen, Germany
| | - S Reinartz
- Department of Radiology, University Hospital RWTH Aachen, Aachen, Germany
| | - T Schmitz-Rode
- Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - U Steinseifer
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - G Wagner
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - J Arens
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany.,Chair in Engineering Organ Support Technologies, Department of Biomechanical Engineering, Faculty of Engineering Technologies, University of Twente, Enschede, The Netherlands
| |
Collapse
|
4
|
Sniderman J, Monagle P, Annich GM, MacLaren G. Hematologic concerns in extracorporeal membrane oxygenation. Res Pract Thromb Haemost 2020; 4:455-468. [PMID: 32548547 PMCID: PMC7292669 DOI: 10.1002/rth2.12346] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2020] [Revised: 03/27/2020] [Accepted: 03/31/2020] [Indexed: 12/16/2022] Open
Abstract
This ISTH "State of the Art" review aims to critically evaluate the hematologic considerations and complications in extracorporeal membrane oxygenation (ECMO). ECMO is experiencing a rapid increase in clinical use, but many questions remain unanswered. The existing literature does not address or explicitly state many pertinent details that may influence hematologic complications and, ultimately, patient outcomes. This review aims to broadly introduce modern ECMO practices, circuit designs, circuit materials, hematologic complications, transfusion-related considerations, age- and size-related differences, and considerations for choosing outcome measures. Relevant studies from the 2019 ISTH Congress in Melbourne, which further advanced our understanding of these processes, will also be highlighted.
Collapse
Affiliation(s)
| | - Paul Monagle
- Department of PaediatricsDepartment of HaematologyUniversity of MelbourneThe Royal Children's HospitalHaematology Research Murdoch Children’s Research InstituteMelbourneVic.Australia
| | - Gail M. Annich
- Department of Critical Care MedicineThe Hospital for Sick ChildrenUniversity of TorontoTorontoOntarioCanada
| | - Graeme MacLaren
- Paediatric ICURoyal Children’s HospitalMelbourneVic.Australia
- Department of PaediatricsUniversity of MelbourneParkvilleVic.Australia
- Cardiothoracic ICUNational University Health SystemSingapore CitySingapore
| |
Collapse
|
5
|
Sharma NS, Hartwig MG, Hayes D. Extracorporeal membrane oxygenation in the pre and post lung transplant period. ANNALS OF TRANSLATIONAL MEDICINE 2017; 5:74. [PMID: 28275619 DOI: 10.21037/atm.2017.02.09] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Abstract
Evolution in technology has resulted in rapid increase in utilization of extracorporeal membrane oxygenation (ECMO) as a bridge to recovery and/or transplantation. Although there is limited evidence for the use of ECMO, recent improvements in ECMO technology, personnel training, ambulatory practices on ECMO and lung protective strategies have resulted in improved outcomes in patients bridged to lung transplantation. This review provides an insight into the current outcomes and best practices for utilization of ECMO in the pre- and post-lung transplantation period.
Collapse
Affiliation(s)
- Nirmal S Sharma
- Division of Pulmonary, Allergy & Critical Care Medicine, University of Alabama at Birmingham, Birmingham AL, USA
| | - Mathew G Hartwig
- Division of Cardiovascular and Thoracic Surgery, Duke University, Durham, NC, USA
| | - Don Hayes
- Departments of Pediatrics, Internal Medicine, and Surgery, The Ohio State University, OH, USA
| |
Collapse
|