Monteiro C, Ferrari ADL, Caramori PRA, Carvalho LAF, Siqueira DADA, Thiago LEKS, Perin M, Lima VCD, Guérios E, Brito Junior FSD. Permanent Pacing After Transcatheter Aortic Valve Implantation: Incidence, Predictors and Evolution of Left Ventricular Function.
Arq Bras Cardiol 2017;
109:550-559. [PMID:
29185614 PMCID:
PMC5783436 DOI:
10.5935/abc.20170170]
[Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2017] [Accepted: 07/12/2017] [Indexed: 12/21/2022] Open
Abstract
Background
Transcatheter aortic valve implantation (TAVI) is a well-established
procedure; however, atrioventricular block requiring permanent pacemaker
implantation (PPI) is a common complication.
Objectives
To determine the incidence, predictors and clinical outcomes of PPI after
TAVI, focusing on how PPI affects left ventricular ejection fraction (LVEF)
after TAVI.
Methods
The Brazilian Multicenter TAVI Registry included 819 patients submitted to
TAVI due to severe aortic stenosis from 22 centers from January/2008 to
January/2015. After exclusions, the predictors of PPI were assessed in 670
patients by use of multivariate regression. Analysis of the ROC curve was
used to measure the ability of the predictors; p < 0.05 was the
significance level adopted.
Results
Within 30 days from TAVI, 135 patients (20.1%) required PPI. Those patients
were older (82.5 vs. 81.1 years; p = 0.047) and mainly of the male sex
(59.3% vs 45%; p = 0.003). Hospital length of stay was longer in patients
submitted to PPI (mean = 15.7 ± 25.7 vs. 11.8 ± 22.9 days; p
< 0.001), but PPI affected neither all-cause death (26.7% vs. 25.6%; p =
0.80) nor cardiovascular death (14.1% vs. 14.8%; p = 0.84). By use of
multivariate analysis, the previous presence of right bundle-branch block
(RBBB) (OR, 6.19; 3.56-10.75; p ≤ 0.001), the use of
CoreValve® prosthesis (OR, 3.16; 1.74-5.72; p ≤
0.001) and baseline transaortic gradient > 50 mm Hg (OR, 1.86; 1.08-3.2;
p = 0.025) were predictors of PPI. The estimated risk of PPI ranged from 4%,
when none of those predictors was present, to 63%, in the presence of all of
them. The model showed good ability to predict the need for PPI: 0.69
(95%CI: 0.64 - 0.74) in the ROC curve. The substudy of 287 echocardiograms
during the 1-year follow-up showed worse LVEF course in patients submitted
to PPI (p = 0.01).
Conclusion
BRD prévio, gradiente aórtico médio > 50 mmHg e
CoreValve® são preditores independentes de implante de MPD
pós-TAVI. Ocorreu implante de MPD em aproximadamente 20% dos casos de
TAVI, o que prolongou a internação hospitalar, mas não
afetou a mortalidade. O implante de MPD afetou negativamente a FEVE
pós-TAVI.
Collapse