Miyasaka Y, Ishizawa T, Nawa Y, Souda H, Kawashiro S, Chai H, Ishizawa M, Sato H, Iwai T. Evaluation of the effect of metal stents on dose perturbation in the carbon beam irradiation field. J Appl Clin Med Phys 2025:e70042. [PMID: 39969236 DOI: 10.1002/acm2.70042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2024] [Revised: 12/24/2024] [Accepted: 01/30/2025] [Indexed: 02/20/2025] Open
Abstract
PROPOSE Carbon ion therapy is indicated for cases in which stents have been inserted, such as bile ducts, but the effect of metal stents on carbon ion therapy is unclear. In this study, the dose perturbation of carbon ion therapy caused by metallic bile duct stents was evaluated by dosimetry. MATERIALS AND METHODS Five different types of metal stents (EGIS Double Bear Biliary Stent, EGIS Single Bear Covered Biliary Stent, BileRush Selective, Niti-S Less Shortening D-type Stent, and ZEO Stent V) were placed between solid phantoms and Gafchromic film were placed around the stents and at each depth. The phantom was irradiated with a Carbon ion Beam to form a 5 cm × 5 cm × 5 cm spread-out Brag peak. The dose change due to the stent was evaluated by comparing the film values of similar irradiations without the stent in place. RESULT The results showed that the dose perturbation with and without the stent was <10%. A dose reduction area along the shape of the stent appeared at the end of the irradiation field. CONCLUSION The effect of metal stents on the carbon dose distribution was assumed to be comparable to that of x-rays and protons.
Collapse
Affiliation(s)
- Yuya Miyasaka
- Department of Heavy Particle Medical Science, Yamagata University Graduate School of Medical Science, Yamagata, Japan
| | - Tetsuya Ishizawa
- Department of Gastroenterology, Yamagata University Faculty of Medicine, Yamagata, Japan
| | - Yoshihito Nawa
- Department of Gastroenterology, Yamagata University Faculty of Medicine, Yamagata, Japan
| | - Hikaru Souda
- Department of Heavy Particle Medical Science, Yamagata University Graduate School of Medical Science, Yamagata, Japan
| | - Shohei Kawashiro
- Department of Radiation Oncology, Kanagawa Cancer Center, Yokohama, Japan
| | - Hongbo Chai
- Department of Heavy Particle Medical Science, Yamagata University Graduate School of Medical Science, Yamagata, Japan
| | - Miyu Ishizawa
- Department of Heavy Particle Medical Science, Yamagata University Graduate School of Medical Science, Yamagata, Japan
| | - Hiraku Sato
- Department of Radiology, Yamagata University Faculty of Medicine, Yamagata, Japan
| | - Takeo Iwai
- Department of Heavy Particle Medical Science, Yamagata University Graduate School of Medical Science, Yamagata, Japan
| |
Collapse
|
2
|
Ban T, Kubota Y, Takahama T, Sasoh S, Tanida S, Nakamura M, Ando T, Joh T. Late-onset Rupture of the Intrahepatic Pseudoaneurysm Developed by Endoscopic Ultrasonography-guided Hepaticogastrostomy: A Case Report and Literature Review. Intern Med 2025; 64:217-223. [PMID: 38811220 PMCID: PMC11802225 DOI: 10.2169/internalmedicine.3717-24] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/23/2024] [Accepted: 04/10/2024] [Indexed: 05/31/2024] Open
Abstract
Endoscopic ultrasonography-guided hepaticogastrostomy (EUS-HGS) has emerged as an alternative drainage technique for patients with malignant biliary obstruction. However, few reports have discussed the occurrence of late-onset rupture of hepatic artery pseudoaneurysms following EUS-HGS. A recently available drill dilator equipped with a long screw segment was used in the dilation step of EUS-HGS. We highlight the potential concern that this long screw segment may increase the risk of damage to the hepatic artery, leading to late-onset life-threatening rupture of a pseudoaneurysm.
Collapse
Affiliation(s)
- Tesshin Ban
- Department of Gastroenterology and Hepatology, Gamagori City Hospital, Japan
| | - Yoshimasa Kubota
- Department of Gastroenterology and Hepatology, Gamagori City Hospital, Japan
| | - Takuya Takahama
- Department of Gastroenterology and Hepatology, Gamagori City Hospital, Japan
| | - Shun Sasoh
- Department of Gastroenterology and Hepatology, Gamagori City Hospital, Japan
| | - Satoshi Tanida
- Department of Gastroenterology and Hepatology, Gamagori City Hospital, Japan
| | - Makoto Nakamura
- Department of Gastroenterology and Hepatology, Gamagori City Hospital, Japan
| | - Tomoaki Ando
- Department of Gastroenterology and Hepatology, Gamagori City Hospital, Japan
| | - Takashi Joh
- Department of Gastroenterology and Hepatology, Gamagori City Hospital, Japan
| |
Collapse
|
3
|
Itonaga M, Kitano M. Endoscopic biliary drainage for distal bile duct obstruction due to pancreatic cancer. Clin Endosc 2025; 58:40-52. [PMID: 39322288 PMCID: PMC11837563 DOI: 10.5946/ce.2023.294] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/28/2023] [Revised: 02/15/2024] [Accepted: 03/05/2024] [Indexed: 09/27/2024] Open
Abstract
Approximately 60% of pancreatic cancers occur in the pancreatic head and may present as obstructive jaundice due to bile duct invasion. Obstructive jaundice often leads to poor general conditions and acute cholangitis, interfering with surgery and chemotherapy and requiring biliary drainage. The first choice of treatment for biliary drainage is the endoscopic transpapillary approach. In unresectable tumors, self-expandable metal stents (SEMSs) are most commonly used and are classified into uncovered and covered SEMSs. Recently, antireflux metal stents and large- or small-diameter SEMSs have become commercially available, and their usefulness has been reported. Plastic stents are infrequently used in patients with resectable biliary obstruction; however, owing to the recent trend in preoperative chemotherapy, SEMSs are frequently used because of the long time to recurrent biliary obstruction. Endoscopic ultrasound-guided biliary drainage (EUS-BD) is often performed in patients who are not eligible for the transpapillary approach, and favorable outcomes have been reported. Different EUS-BD techniques and specialized stents have been developed and can be safely used in high-volume centers. The indications for EUS-BD are expected to further expand in the future.
Collapse
Affiliation(s)
- Masahiro Itonaga
- Second Department of Internal Medicine, Wakayama Medical University, Wakayama City, Japan
| | - Masayuki Kitano
- Second Department of Internal Medicine, Wakayama Medical University, Wakayama City, Japan
| |
Collapse
|
4
|
Ueda Y, Ikezawa K, Sagawa T, Isono M, Ohira S, Miyazaki M, Takada R, Yamai T, Ohkawa K, Teshima T, Konishi K. Dosimetric characteristics of self-expandable metallic and plastic stents for transpapillary biliary decompression in external beam radiotherapy. Phys Eng Sci Med 2024; 47:1323-1335. [PMID: 38976186 DOI: 10.1007/s13246-024-01447-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2022] [Accepted: 05/21/2024] [Indexed: 07/09/2024]
Abstract
There is little evidence regarding radiation dose perturbation caused by the self-expandable metallic stents (SEMSs) used for transpapillary biliary decompression. We aimed to compare SEMSs with plastic stents (PSs) and clarify their dosimetric characteristics. Fifteen SEMSs (10 braided and 5 lasercut type) and six PSs (diameter: 2.3-3.3 mm) were inserted into a water-equivalent solid phantom. In total, 13 SEMSs had radiopaque markers, whereas the other two did not. Using radiochromic films, the dose difference adjacent to the stents at locations proximal, distal, and arc delivery to the radiation source was evaluated based on comparison to measurement of the dose delivery in phantom without any stent in place. The median values of the dose difference for each stent were used to compare the SEMS and PS groups.Results: The dose difference (median (minimum/maximum)) was as follows: proximal, SEMSs + 2.1% (1.8 / 4.7) / PSs + 5.4% (4.1 / 6.3) (p < 0.001); distal, SEMSs -1.0% (-1.6 /-0.4) / PSs -8.9% (-11.7 / -7.4) (p < 0.001); arc delivery, SEMSs 1.2% (0.9 / 2.3) / PSs 2.2% (1.6 / 3.6) (p = 0.005). These results demonstrated that the dose differences of SEMSs were significantly smaller than those of PSs. On the other hand, the dose difference was large at surface of the radiopaque markers for SEMSs: proximal, 10.3% (7.2 / 20.9); distal, -8.4% (-16.3 / -4.2); arc delivery, 5.5% (4.2 / 9.2). SEMSs for biliary decompression can be safely used in patients undergoing radiotherapy, by focusing on the dose distribution around the stents and by paying attention to local changes in the dose distribution of radiopaque markers.
Collapse
Affiliation(s)
- Yoshihiro Ueda
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, 3-1-69, Otemae, Chuo-ku, Osaka, 537-8567, Japan.
| | - Kenji Ikezawa
- Department of Hepatobiliary and Pancreatic Oncology, Osaka International Cancer Institute, 3-1-69, Otemae, Chuo-ku, Osaka, 537-8567, Japan
| | - Tomohiro Sagawa
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, 3-1-69, Otemae, Chuo-ku, Osaka, 537-8567, Japan
| | - Masaru Isono
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, 3-1-69, Otemae, Chuo-ku, Osaka, 537-8567, Japan
| | - Shingo Ohira
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, 3-1-69, Otemae, Chuo-ku, Osaka, 537-8567, Japan
| | - Masayoshi Miyazaki
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, 3-1-69, Otemae, Chuo-ku, Osaka, 537-8567, Japan
| | - Ryoji Takada
- Department of Hepatobiliary and Pancreatic Oncology, Osaka International Cancer Institute, 3-1-69, Otemae, Chuo-ku, Osaka, 537-8567, Japan
| | - Takuo Yamai
- Department of Hepatobiliary and Pancreatic Oncology, Osaka International Cancer Institute, 3-1-69, Otemae, Chuo-ku, Osaka, 537-8567, Japan
| | - Kazuyoshi Ohkawa
- Department of Hepatobiliary and Pancreatic Oncology, Osaka International Cancer Institute, 3-1-69, Otemae, Chuo-ku, Osaka, 537-8567, Japan
| | - Teruki Teshima
- Department of Radiation Oncology, Osaka Heavy Ion Therapy Center, 3-1-10, Otemae, Chuo-ku, Osaka, 540-0008, Japan
| | - Koji Konishi
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, 3-1-69, Otemae, Chuo-ku, Osaka, 537-8567, Japan
| |
Collapse
|
5
|
Li Y, Yuan K, Deng C, Tang H, Wang J, Dai X, Zhang B, Sun Z, Ren G, Zhang H, Wang G. Biliary stents for active materials and surface modification: Recent advances and future perspectives. Bioact Mater 2024; 42:587-612. [PMID: 39314863 PMCID: PMC11417150 DOI: 10.1016/j.bioactmat.2024.08.031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2024] [Revised: 08/27/2024] [Accepted: 08/27/2024] [Indexed: 09/25/2024] Open
Abstract
Demand for biliary stents has expanded with the increasing incidence of biliary disease. The implantation of plastic or self-expandable metal stents can be an effective treatment for biliary strictures. However, these stents are nondegradable and prone to restenosis. Surgical removal or replacement of the nondegradable stents is necessary in cases of disease resolution or restenosis. To overcome these shortcomings, improvements were made to the materials and surfaces used for the stents. First, this paper reviews the advantages and limitations of nondegradable stents. Second, emphasis is placed on biodegradable polymer and biodegradable metal stents, along with functional coatings. This also encompasses tissue engineering & 3D-printed stents were highlighted. Finally, the future perspectives of biliary stents, including pro-epithelialization coatings, multifunctional coated stents, biodegradable shape memory stents, and 4D bioprinting, were discussed.
Collapse
Affiliation(s)
- Yuechuan Li
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, National Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing, 400044, China
- National United Engineering Laboratory for Biomedical Material Modification, Dezhou, 251100, China
| | - Kunshan Yuan
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, National Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing, 400044, China
- National United Engineering Laboratory for Biomedical Material Modification, Dezhou, 251100, China
| | - Chengchen Deng
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, National Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing, 400044, China
- National United Engineering Laboratory for Biomedical Material Modification, Dezhou, 251100, China
| | - Hui Tang
- Shanghai Tenth People's Hospital, School of Medicine, Tongji University, Shanghai, 200092, China
- National United Engineering Laboratory for Biomedical Material Modification, Dezhou, 251100, China
| | - Jinxuan Wang
- School of Biosciences and Technology, Chengdu Medical College, Chengdu, 610500, China
| | - Xiaozhen Dai
- School of Biosciences and Technology, Chengdu Medical College, Chengdu, 610500, China
| | - Bing Zhang
- Nanjing Key Laboratory for Cardiovascular Information and Health Engineering Medicine (CVIHEM), Drum Tower Hospital, Nanjing University, Nanjing, China
| | - Ziru Sun
- National United Engineering Laboratory for Biomedical Material Modification, Dezhou, 251100, China
- College of materials science and engineering, Shandong University of Technology, Zibo, 25500, Shandong, China
| | - Guiying Ren
- National United Engineering Laboratory for Biomedical Material Modification, Dezhou, 251100, China
- College of materials science and engineering, Shandong University of Technology, Zibo, 25500, Shandong, China
| | - Haijun Zhang
- Shanghai Tenth People's Hospital, School of Medicine, Tongji University, Shanghai, 200092, China
- National United Engineering Laboratory for Biomedical Material Modification, Dezhou, 251100, China
| | - Guixue Wang
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, National Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing, 400044, China
- School of Biosciences and Technology, Chengdu Medical College, Chengdu, 610500, China
- Nanjing Key Laboratory for Cardiovascular Information and Health Engineering Medicine (CVIHEM), Drum Tower Hospital, Nanjing University, Nanjing, China
| |
Collapse
|
6
|
Koga T, Yamada H, Ishida Y, Tsuchiya N, Kitaguchi T, Matsumoto K, Fukuyama M, Kojima N, Hirai F. Radial force and wire structure determine the onset of covered self-expandable metal stent migration in endoscopic ultrasound-guided hepaticogastrostomy: Measurement of sliding-resistance force using a porcine model. JOURNAL OF HEPATO-BILIARY-PANCREATIC SCIENCES 2024; 31:840-849. [PMID: 39075945 DOI: 10.1002/jhbp.12050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/31/2024]
Abstract
BACKGROUND Self-expandable metal stent (SEMS) migration after endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) is a severe complication. The migration risk could be related to the surface friction of SEMS, assumed to be affected by the wire structure and mechanical properties, including radial force (RF); however, their relevance remains unclear. This experimental study aimed to assess the mechanical properties of SEMS involved in the onset of stent migration by measuring the sliding-resistance force (SF) as the SEMS moves through the stomach wall. METHODS The SF of seven types of 8-mm diameter SEMS (four braided and three laser-cut types) and porcine stomach wall was measured with a universal testing machine. The SF of each SEMS was measured three times, and the average maximum SF (SFmax) was used for analysis. The correlation between SFmax and RF of each SEMS was evaluated. RESULTS SFmax and RF showed a very strong positive correlation (r = 0.92). Compared to the regression line predictions in the scatter plots of SFmax and RF, the SFmax of laser-cut and braided type SEMSs had positive and negative residuals, respectively. CONCLUSIONS Selecting a laser-cut type SEMS with a higher RF may more effectively prevent the onset of stent migration against the stomach wall in EUS-HGS.
Collapse
Affiliation(s)
- Takehiko Koga
- Department of Gastroenterology and Medicine, Fukuoka University Faculty of Medicine, Fukuoka, Japan
| | - Hiroshi Yamada
- Department of Biological Functions Engineering, Graduate School of Life Science and Systems Engineering, Kyushu Institute of Technology, Kitakyushu, Japan
| | - Yusuke Ishida
- Department of Gastroenterology and Medicine, Fukuoka University Faculty of Medicine, Fukuoka, Japan
| | - Naoaki Tsuchiya
- Department of Gastroenterology and Medicine, Fukuoka University Faculty of Medicine, Fukuoka, Japan
| | - Takanori Kitaguchi
- Department of Gastroenterology and Medicine, Fukuoka University Faculty of Medicine, Fukuoka, Japan
| | - Keisuke Matsumoto
- Department of Gastroenterology and Medicine, Fukuoka University Faculty of Medicine, Fukuoka, Japan
| | - Makoto Fukuyama
- Department of Gastroenterology and Medicine, Fukuoka University Faculty of Medicine, Fukuoka, Japan
| | - Norihiro Kojima
- Department of Gastroenterology, Taragi Municipal Hospital, Kumamoto, Japan
| | - Fumihito Hirai
- Department of Gastroenterology and Medicine, Fukuoka University Faculty of Medicine, Fukuoka, Japan
| |
Collapse
|
7
|
Vanaei S, Hashemi M, Solouk A, Asghari Ilani M, Amili O, Hefzy MS, Tang Y, Elahinia M. Manufacturing, Processing, and Characterization of Self-Expanding Metallic Stents: A Comprehensive Review. Bioengineering (Basel) 2024; 11:983. [PMID: 39451359 PMCID: PMC11505524 DOI: 10.3390/bioengineering11100983] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2024] [Revised: 08/31/2024] [Accepted: 09/03/2024] [Indexed: 10/26/2024] Open
Abstract
This paper aims to review the State of the Art in metal self-expanding stents made from nitinol (NiTi), showing shape memory and superelastic behaviors, to identify the challenges and the opportunities for improving patient outcomes. A significant contribution of this paper is its extensive coverage of multidisciplinary aspects, including design, simulation, materials development, manufacturing, bio/hemocompatibility, biomechanics, biomimicry, patency, and testing methodologies. Additionally, the paper offers in-depth insights into the latest practices and emerging trends, with a special emphasis on the transformative potential of additive manufacturing techniques in the development of metal stents. By consolidating existing knowledge and highlighting areas for future innovation, this review provides a valuable roadmap for advancing nitinol stents.
Collapse
Affiliation(s)
- Saeedeh Vanaei
- Mechanical Industrial and Manufacturing Engineering Department, University of Toledo, Toledo, OH 43606, USA; (O.A.); (M.S.H.); (M.E.)
| | - Mahdi Hashemi
- Department of Materials and Metallurgical Engineering, Amirkabir University of Technology, Tehran 1591634311, Iran;
| | - Atefeh Solouk
- Biomedical Engineering Department, Amirkabir University of Technology (Tehran Polytechnic), Tehran 1591634311, Iran;
| | - Mohsen Asghari Ilani
- School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran 1439957131, Iran;
| | - Omid Amili
- Mechanical Industrial and Manufacturing Engineering Department, University of Toledo, Toledo, OH 43606, USA; (O.A.); (M.S.H.); (M.E.)
| | - Mohamed Samir Hefzy
- Mechanical Industrial and Manufacturing Engineering Department, University of Toledo, Toledo, OH 43606, USA; (O.A.); (M.S.H.); (M.E.)
| | - Yuan Tang
- Department of Bioengineering, University of Toledo, Toledo, OH 43606, USA;
| | - Mohammad Elahinia
- Mechanical Industrial and Manufacturing Engineering Department, University of Toledo, Toledo, OH 43606, USA; (O.A.); (M.S.H.); (M.E.)
| |
Collapse
|
8
|
Nakagawa H, Takeda T, Okamoto T, Mie T, Kasuga A, Sasaki T, Ozaka M, Matsuda T, Igarashi Y, Sasahira N. Outcomes of 6-mm diameter fully covered self-expandable metal stents for preoperative biliary drainage in pancreatic cancer. DEN OPEN 2024; 4:e360. [PMID: 38601271 PMCID: PMC11004548 DOI: 10.1002/deo2.360] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/18/2024] [Revised: 03/15/2024] [Accepted: 03/24/2024] [Indexed: 04/12/2024]
Abstract
Background 10-mm self-expandable metal stents (SEMSs) are commonly used for preoperative biliary drainage in pancreatic cancer. However, smaller diameter SEMSs have attracted attention with the attempt to reduce stent-related adverse events (AEs). Methods We retrospectively analyzed consecutive borderline resectable pancreatic cancer patients who underwent neoadjuvant therapy and fully covered SEMS (FCSEMS) placement from April 2015 to May 2023. The primary outcome was stent-related non-event rate (NER), which was defined as the rate of completion of surgery without developing any preoperative events (recurrent biliary obstruction [RBO] or stent-related AEs). Secondary outcomes included stent-related AEs, causes of RBO, and cumulative incidence of RBO. Risk factors for pancreatitis, RBO, and stent migration were also examined. Results A total of 76 patients were included (6-mm group: 23; 10-mm group: 53). Stent-related NER (57% vs. 64%, p = 0.610), stent-related AEs (4% vs. 15%, p = 0.263), overall RBO rates (39% vs. 23%, p = 0.168), cumulative incidence of RBO (hazard ratio, 2.24; 95% confidence interval, 0.95-5.25; p = 0.065) were not significantly different between the two groups. Tumor involvement of the pancreatic duct was identified as a risk-reducing factor for pancreatitis, while an FCSEMS diameter of 6 mm was not identified as a risk factor for RBO and stent migration. Conclusions Stent-related NER was not significantly affected by FCSEMS diameter. Further studies are needed to confirm the usefulness of 6-mm diameter FCSEMS for preoperative biliary drainage in patients with borderline resectable pancreatic cancer.
Collapse
Affiliation(s)
- Hiroki Nakagawa
- Department of Hepato‐Biliary‐Pancreatic MedicineCancer Institute Hospital of Japanese Foundation for Cancer ResearchTokyoJapan
- Department of Internal MedicineDivision of Gastroenterology and Hepatology, Omori Medical CenterToho UniversityTokyoJapan
| | - Tsuyoshi Takeda
- Department of Hepato‐Biliary‐Pancreatic MedicineCancer Institute Hospital of Japanese Foundation for Cancer ResearchTokyoJapan
| | - Takeshi Okamoto
- Department of Hepato‐Biliary‐Pancreatic MedicineCancer Institute Hospital of Japanese Foundation for Cancer ResearchTokyoJapan
| | - Takafumi Mie
- Department of Hepato‐Biliary‐Pancreatic MedicineCancer Institute Hospital of Japanese Foundation for Cancer ResearchTokyoJapan
| | - Akiyoshi Kasuga
- Department of Hepato‐Biliary‐Pancreatic MedicineCancer Institute Hospital of Japanese Foundation for Cancer ResearchTokyoJapan
| | - Takashi Sasaki
- Department of Hepato‐Biliary‐Pancreatic MedicineCancer Institute Hospital of Japanese Foundation for Cancer ResearchTokyoJapan
| | - Masato Ozaka
- Department of Hepato‐Biliary‐Pancreatic MedicineCancer Institute Hospital of Japanese Foundation for Cancer ResearchTokyoJapan
| | - Takahisa Matsuda
- Department of Internal MedicineDivision of Gastroenterology and Hepatology, Omori Medical CenterToho UniversityTokyoJapan
| | - Yoshinori Igarashi
- Department of Internal MedicineDivision of Gastroenterology and Hepatology, Omori Medical CenterToho UniversityTokyoJapan
| | - Naoki Sasahira
- Department of Hepato‐Biliary‐Pancreatic MedicineCancer Institute Hospital of Japanese Foundation for Cancer ResearchTokyoJapan
| |
Collapse
|
9
|
Tsauo J, Fu Y, Liu Y, Zhang X, Zhao H, Li X. Characteristics of four commonly used self-expanding biliary stents: an in vitro study. Eur Radiol Exp 2024; 8:24. [PMID: 38369648 PMCID: PMC10874915 DOI: 10.1186/s41747-024-00425-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2023] [Accepted: 12/19/2023] [Indexed: 02/20/2024] Open
Abstract
BACKGROUND Knowledge of the characteristics of self-expanding metal stents (SEMSs) is essential during selection process to ensure the best therapeutic outcomes for patients with malignant biliary obstruction. The aim of this study was to evaluate the characteristics of four commonly used SEMSs. METHODS This in vitro study analyzed the radial force (RF), crush resistance (CR), axial force (AF), conformability, surface quality, foreshortening, and radiopacity of the following SEMSs: uncovered Wallflex™, EGIS single bare, Zilver 635®, and E-Luminexx™. Two samples of each SEMS type were included in this study, all having identical specifications with a diameter of 10 mm and a length of 6 cm. One sample from each type was analyzed for surface quality, followed by CR, conformability, and foreshortening. The other sample was analyzed for radiopacity, followed by RF and AF. RESULTS The uncovered Wallflex™ exhibited low RF, high CR, high AF, good conformability, poor surface quality, high foreshortening, and good radiopacity. The EGIS single bare demonstrated high RF, high CR, low AF, moderate conformability, good surface quality, high foreshortening, and poor radiopacity. The Zilver 635® displayed moderate RF, low CR, low AF, moderate conformability, moderate surface quality, no foreshortening, and good radiopacity. The E-Luminexx™ showed high RF, moderate CR, high AF, poor conformability, poor surface quality, no foreshortening, and good radiopacity. CONCLUSIONS There was considerable variation in the characteristics among the four evaluated SEMSs. These characteristics should be carefully considered during selection to ensure optimal therapeutic outcomes for patients. RELEVANCE STATEMENT The selection of self-expanding metal stents for treating malignant biliary obstruction requires careful consideration of various characteristics, including their radial force, crush resistance, axial force, conformability, surface quality, foreshortening, and radiopacity. KEY POINTS • The characteristics of self-expanding metal stents (SEMSs) can vary considerably. • Specific situations may warrant the use of SEMSs with particular characteristics over others. • Characteristics of SEMSs must be considered during selection for optimal outcomes.
Collapse
Affiliation(s)
- Jiaywei Tsauo
- Department of Interventional Therapy, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, China
- Department of Interventional Radiology, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, Guangdong, 510080, China
| | - Yan Fu
- Department of Interventional Therapy, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, China
| | - Yue Liu
- Department of Etiology and Carcinogenesis and State Key Laboratory of Molecular Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, China
| | - Xiaowu Zhang
- Department of Interventional Therapy, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, China.
| | - He Zhao
- Department of Interventional Therapy, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, China
| | - Xiao Li
- Department of Interventional Therapy, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, China.
| |
Collapse
|
10
|
Cho KB. How to reduce fistula formation after self-expandable metallic stent insertion for treating malignant esophageal stricture? Clin Endosc 2023; 56:735-737. [PMID: 37981742 PMCID: PMC10665625 DOI: 10.5946/ce.2023.257] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/10/2023] [Revised: 10/28/2023] [Accepted: 10/29/2023] [Indexed: 11/21/2023] Open
Affiliation(s)
- Kwang Bum Cho
- Department of Internal Medicine, Keimyung University School of Medicine, Daegu, Korea
| |
Collapse
|
11
|
Jeong S. Understanding mechanical properties of biliary metal stents for wise stent selection. Clin Endosc 2023; 56:592-593. [PMID: 37743066 PMCID: PMC10565435 DOI: 10.5946/ce.2023.206] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/25/2023] [Revised: 09/04/2023] [Accepted: 09/05/2023] [Indexed: 09/26/2023] Open
Affiliation(s)
- Seok Jeong
- Department of Internal Medicine, Inha University College of Medicine, Incheon, Korea
| |
Collapse
|