1
|
Tamburro R, Bianchi A, Paolini A, Bongiovanni L, Della Salda L, Collivignarelli F, Niebauer GW, Ceballos JL, Teofani M, Bussadori R. Histomorphological evaluation of thermal injury following palatoplasty performed with CO 2 laser or LigaSure device in dogs with brachycephalic obstructive airway syndrome. Vet J 2024; 307:106195. [PMID: 39002814 DOI: 10.1016/j.tvjl.2024.106195] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2024] [Revised: 07/03/2024] [Accepted: 07/04/2024] [Indexed: 07/15/2024]
Abstract
The elongated soft palate is an abnormality that characterizes most brachycephalic dogs and contributes to the brachycephalic obstructive airway syndrome (BOAS). Palatoplasty is routinely performed in brachycephalic dogs; several surgical techniques exist. The use of surgical instruments such as monopolar electrocoagulation, CO2 or diode laser, bipolar vessel sealing device and harmonic shears has become routine to reduce the operating time, the intraoperative risk of bleeding and the postoperative oedema. This prospective study aimed to compare the histomorphological effect of a CO2 laser and LigaSure device in palates of dogs undergoing palatoplasty. Twenty owned brachycephalic dogs were included, 10 palatoplasties were performed using CO2 laser and 10 using LigaSure™ device. The dogs were positioned in sternal recumbency. A transoral approach was performed: the elongated soft palate was grasped with Allis forceps and brought rostrally, the palatoplasty was performed using the tonsillar crypts as anatomical landmarks. Surgical specimens were routinely fixed in 10 % formalin. Two sections perpendicular to the surgical margins were trimmed from each sample, paraffin-embedded and stained with hematoxylin and eosin (H&E). Tissue damage induced by the two types of surgical devices was graded (1-4, from minimal to severe) and the depth of thermal injury measured in μm on captured images (using an image analysis program - ImageJ). Mean values and standard deviations (SD) were calculated based on six measurements for each sample. The tissue damage was graded 3.7±0.48 in group LigaSure™ and 2.8±1 in group Laser. The mean depth of thermal injury was 874.94±184.92 μm in the LigaSure™ group and 451,76±137,86 μm in the Laser group. The comparison between the two groups showed significant lower grade and extension of thermal injury in the palate samples obtained with CO2 laser (p<0.05). Additionally, there is a lack of literature that correlates the histological changes with the clinical outcomes of the different palatoplasty methods in brachycephalic dogs. By comparing histological changes and clinical outcomes, we aim to provide valuable insights for optimizing the surgical approach for palatoplasty in brachycephalic dogs, ultimately improving postoperative outcomes for these patients.
Collapse
Affiliation(s)
- Roberto Tamburro
- Department of Veterinary Medicine, University of Teramo, SP18 Piano D'accio, Teramo 64100, Italy
| | - Amanda Bianchi
- Department of Veterinary Medicine, University of Teramo, SP18 Piano D'accio, Teramo 64100, Italy.
| | - Andrea Paolini
- Department of Veterinary Medicine, University of Teramo, SP18 Piano D'accio, Teramo 64100, Italy
| | - Laura Bongiovanni
- Department of Veterinary Medicine, University of Teramo, SP18 Piano D'accio, Teramo 64100, Italy; Department of Biomolecular Sciences, Faculty of Veterinary Medicine, Utrecht University, Utrecht, the Netherlands
| | - Leonardo Della Salda
- Department of Veterinary Medicine, University of Teramo, SP18 Piano D'accio, Teramo 64100, Italy
| | | | - Gert W Niebauer
- Department of Veterinary Medicine, University of Teramo, SP18 Piano D'accio, Teramo 64100, Italy; Department of Veterinary Medicine, University of Naples, via Federcio Delpino 1, Naples 80137, Italy
| | - Jorge Llinas Ceballos
- AniCura Valencia Sur Veterinary Hospital, Av. De Picassent 28, Silla, Valencia 46460, Spain
| | - Melissa Teofani
- Department of Veterinary Medicine, University of Teramo, SP18 Piano D'accio, Teramo 64100, Italy
| | | |
Collapse
|
2
|
Parlar Oz O, Karagozoglu İ, Kocer I, Demırkol N, Zer Y. The effect of laser therapy for the treatment of dentin hypersensitivity on surface roughness and bacterial adhesion. Lasers Med Sci 2024; 39:212. [PMID: 39120679 PMCID: PMC11315743 DOI: 10.1007/s10103-024-04166-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Accepted: 07/31/2024] [Indexed: 08/10/2024]
Abstract
The aim of the study was to measure the degree of dentine surface roughness caused by five distinct lasers used to treat dentine hypersensitivity, as well as to evaluate the subsequent bacterial colonization on these irradiated surfaces. Sixty human maxillary premolar teeth without caries or restoration which were extracted for periodontal reasons were used in this study. Five different types of lasers were applied to the root dentin surface. Tested samples were divided into six groups of 10 samples each; control, diode (810 nm), diode (980 nm), Nd: YAG, Er: YAG, and Er, Cr: YSGG laser groups. The arithmetic mean of the surface roughness values (Ra) and the average roughness over a measurement area (Sa) were measured pre- and post-application using any of the laser types. Swab samples were then collected from the dentin surface. Following a 24-hour incubation period at 37 °C, the colony forming units were counted using a stereoscope. The results demonstrated a statistically significant difference in the surface roughness values pre- and post-application (Ra and Sa, respectively) in the Er, Cr: YSGG laser group (p = 0.037,p = 0.007). No significant difference was observed in the other groups (p > 0.05). There was no statistically significant difference in the number of bacterial colonies observed between the test and control groups. Diode and Nd: YAG lasers showed either a decrease or no change in surface roughness; however, the hard tissue lasers (Er: YAG, Er, Cr: YSGG) showed an increase. The Er: YAG and Nd: YAG laser groups exhibited decreased bacterial adhesion compared to the other groups.
Collapse
Affiliation(s)
- Ozge Parlar Oz
- Faculty of Dentistry, Department of Prosthodontics, Gaziantep University, Gaziantep, Turkey
| | - İrem Karagozoglu
- Faculty of Dentistry, Department of Prosthodontics, Gaziantep University, Gaziantep, Turkey.
| | - Ipek Kocer
- Faculty of medicine, Department of medical microbiology, Sanko University, Gaziantep, Turkey
| | - Nermin Demırkol
- Faculty of Dentistry, Department of Prosthodontics, Gaziantep University, Gaziantep, Turkey
| | - Yasemin Zer
- Faculty of Medicine, Department of medical microbiology, Gaziantep University, Gaziantep, Turkey
| |
Collapse
|
3
|
Hosseini Mehvar B, Azizi A, Lavaf S, Etemadi A, Hassani A. Temperature Rise and Pain Following the Use of 810 and 980 nm Diode Lasers for Second-Stage Dental Implant Surgery: A Clinical Trial. J Lasers Med Sci 2024; 15:e29. [PMID: 39188932 PMCID: PMC11345799 DOI: 10.34172/jlms.2024.29] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2023] [Accepted: 05/14/2024] [Indexed: 08/28/2024]
Abstract
Introduction: Many surgical procedures in a soft tissue are performed using diodes lasers. This study aimed to assess the temperature rise and pain following the use of 810 and 980 nm diode lasers for second-stage dental implant surgery. Methods: This clinical trial was conducted on 24 osseointegrated dental implants that were randomly divided into two groups of 810 nm and 980 nm diode lasers. The temperature rise in each group was measured right after uncovering by the laser and 15 minutes later by a thermocouple, compared with the baseline temperature of gingival tissue. The level of pain was also measured at 24 hours postoperatively by using a visual analog scale. Data were analyzed by ANOVA, Tukey's test, and t test (alpha=0.05). Results: Within-group comparisons by ANOVA showed a significant difference in tissue temperature between the three time points in both groups (P<0.0001). Pairwise comparisons by Tukey's test showed that the temperature at baseline (P<0.0001) and 15 seconds after uncovering was significantly lower than that immediately after uncovering in both groups (P<0.0001). The mean tissue temperature and the mean pain score in the 980 nm laser group were significantly higher than the corresponding values in the 810 nm laser group (P<0.05). Conclusion: According to the results, temperature rise in the use of the 980 nm laser was higher than the 810 nm laser. The use of 810 nm diode laser was associated with lower temperature rise and significantly lower pain score after 24 hours.
Collapse
Affiliation(s)
- Bahareh Hosseini Mehvar
- Department of Oral Medicine, Faculty of Dentistry, Tehran Medical Sciences, Islamic Azad University, Tehran, Iran
| | - Arash Azizi
- Department of Oral Medicine, Faculty of Dentistry, Tehran Medical Sciences, Islamic Azad University, Tehran, Iran
| | - Shirin Lavaf
- Department of Prosthodontics, Faculty of Dentistry, Tehran Medical Sciences, Islamic Azad University, Tehran, Iran
| | - Ardavan Etemadi
- Department of Periodontics, Faculty of Dentistry, Tehran Medical Sciences, Islamic Azad University, Tehran, Iran
| | - Ali Hassani
- Department of Oral and Maxillofacial Surgery, Tehran Medical Sciences, Islamic Azad University, Tehran, Iran
| |
Collapse
|
4
|
Al-Ani AJ, Al-Alawi AS, Taher HJ. Analysis of the Temperature Elevation of the Dual-Wavelength Diode Laser and the Er, Cr: YSGG Laser in Oral Soft Tissue Incisions. J Lasers Med Sci 2023; 14:e37. [PMID: 38028884 PMCID: PMC10658115 DOI: 10.34172/jlms.2023.37] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2023] [Accepted: 07/26/2023] [Indexed: 12/01/2023]
Abstract
Introduction: Lasers are one of the most advantageous tools that have been used in a variety of medical fields. Soft tissue management is an important part of oral and maxillofacial surgery. There are different surgical procedures for management; one of them is laser surgery. The purpose of this study was to compare the dual-wavelength diode laser and the Er, Cr: YSGG laser to choose the most effective laser for a soft tissue incision in oral and maxillofacial surgery regarding temperature elevation. Methods: A dual-wavelength diode laser (810 and 980 nm) with 1.5 W and 2.5 W power outputs and an Er, Cr: YSGG (2780 nm) with 2.5 W and 3.5 W power outputs were used to make 50 incisions in six freshly dissected sheep tongues. The temperature means were measured at initial, maximum temperatures, as well as the temperature rise (difference between initial and maximum), and all were compared between the groups of soft tissue. Results: The lowest mean temperature rise was observed with a 2.5 W Er, Cr: YSGG laser, and the highest mean temperature rise was observed with a 2.5 W diode laser, and all samples from the two lasers showed a statistically significant difference (P<0.05) in the temperature rise except the 1.5 W diode, which is higher but not statistically significantly different from the 3.5 W Er, Cr: YSGG laser (P=0.100). Conclusion: The power output of 2.5 W of an Er, Cr: YSGG laser produced low levels of temperature rise compared to a diode laser and produced surgical incisions with a lower probability of heat damage to surrounding tissues.
Collapse
Affiliation(s)
- Alaa Jamal Al-Ani
- Medical and Biological applications Branch, Institute of Laser for Postgraduate Studies, University of Baghdad, Baghdad, Iraq
| | - Ammar Saleh Al-Alawi
- Laser/Dentistry (Oral Surgery), Al-Emamein Al-Kadhemein Medical City, Baghdad, Iraq
| | - Hanan Jafer Taher
- Photonics Units, Institute of Laser for Postgraduate Studies, University of Baghdad, Baghdad, Iraq
| |
Collapse
|
5
|
Diab HM, El-Malt MA, Mourad YO. Evaluation of the effectiveness of photobiomodulation therapy as an alternative method to local anesthesia injection in pediatric dentistry. J Indian Soc Pedod Prev Dent 2023; 41:222-227. [PMID: 37861636 DOI: 10.4103/jisppd.jisppd_305_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/21/2023] Open
Abstract
Background The idea of receiving local anesthesia (LA) via an injection is a major source of dental fear and anxiety. In children, dental anxiety is considered the main reason for avoiding dental treatments. Moreover, there are potential complications during/after LA administration. Thus, it is necessary to search for painless, low-risk, and nonpharmacological anesthetic approaches. Aim This study was performed to evaluate the effectiveness of photobiomodulation (PBM) therapy as an alternative method to LA injection for conventional restorative treatments in pediatric patients. Settings and Design This was a split-mouth randomized clinical study. Materials and Methods The study included 15 children between 6 and 12 years old. Each child had 2 similar contralateral caries lesions in the first permanent molars in the same jaw, total (30) teeth. For each child, one tooth was treated under conventional LA injection and the other was treated under PBM-based anesthesia. The Wong-Baker's Faces Pain Scale was used for reporting the pain and discomfort levels at the end of the treatments. Statistical Analysis Data statistical analysis was performed using the Statistical Package for the Social Sciences (SPSS) version 20. Mann-Whitney U-test was used to compare between the groups. Results The PBM-based anesthesia group recorded a mean pain score of 2.27 ± 1.28. The conventional LA group recorded a mean pain score of 1.73 ± 0.7. The difference between the groups was not statistically significant (P = 0.168). Conclusions PBM-based anesthesia may be an optional alternative to LA injection for conventional restorative treatments in children with dental anxiety, needle phobia, or special needs, and it deserves further studies and improvement.
Collapse
Affiliation(s)
- Hajar Mahmoud Diab
- Department of Pedodontics and Oral Health, Faculty of Dental Medicine for Girls, Al-Azhar University, Cairo, Egypt
| | - Magda A El-Malt
- Department of Pedodontics and Oral Health, Faculty of Dental Medicine for Girls, Al-Azhar University, Cairo, Egypt
| | - Yomna Osama Mourad
- Department of Pedodontics and Oral Health, Faculty of Dental Medicine for Girls, Al-Azhar University, Cairo, Egypt
| |
Collapse
|
6
|
Prado MCO, Nwizu NN, Patel SA, Streckfus CF, Zezell DM, Barros J. Thermal damage and excision time of micro and super pulsed diode lasers: A comparative ex vivo analysis. Clin Exp Dent Res 2022; 8:1655-1663. [PMID: 36218194 PMCID: PMC9760131 DOI: 10.1002/cre2.670] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2022] [Revised: 06/21/2022] [Accepted: 06/24/2022] [Indexed: 11/07/2022] Open
Abstract
OBJECTIVES The primary aim of this ex vivo study was to evaluate thermal damage and cutting efficiency of micro and super pulsed diode lasers. The secondary aim was to suggest a guideline to perform simple surgical excisions adequate for histopathological evaluation. MATERIAL AND METHODS Ten groups of 10 specimens of pig tongues were excised using a blade (G1), a micro pulsed (G2-G9), and a super pulsed diode (G10) lasers. Different output power, pulse duration, pulse interval, and duty cycle were tested. Quantitative measures of thermal damage and excision times were recorded. Statistical analysis was performed at a significance level of 5%. RESULTS The control group (G1) presented no thermal damage. Within the laser groups (G2-G10), no statistically significant differences in depth of thermal damage (µm) were noted. G3 showed significantly less area of thermal damage (mm2 ) when compared with G7 and G9 (p < .05). The median excision time of the control group and super pulsed diode laser group were significantly lower (p < .001) than the micro pulsed diode laser groups. CONCLUSIONS The cutting efficiency of the super pulsed diode laser is comparable to traditional blade, and with appropriate parameters, these lasers can produce predictable surgical outcomes with less collateral damage.
Collapse
Affiliation(s)
- Mariliza C. O. Prado
- Laboratory of Biophotonics, Center for Lasers and ApplicationsIPEN‐CNEN/SPSão PauloSão PauloBrazil
| | - Ngozi N. Nwizu
- Department of Diagnostic and Biomedical Sciences, University of Texas Health Science Center at HoustonSchool of DentistryHoustonTexasUSA
| | - Shalizeh A. Patel
- Department of Restorative Dentistry & Prosthodontics, University of Texas Health Science Center at HoustonSchool of DentistryHoustonTexasUSA
| | - Charles F. Streckfus
- Department of Diagnostic and Biomedical Sciences, University of Texas Health Science Center at HoustonSchool of DentistryHoustonTexasUSA
| | - Denise Maria Zezell
- Laboratory of Biophotonics, Center for Lasers and ApplicationsIPEN‐CNEN/SPSão PauloSão PauloBrazil
| | - Juliana Barros
- Department of Restorative Dentistry & Prosthodontics, University of Texas Health Science Center at HoustonSchool of DentistryHoustonTexasUSA
| |
Collapse
|
7
|
Lesniewski A, Estrin N, Romanos GE. Comparing the Use of Diode Lasers to Light-Emitting Diode Phototherapy in Oral Soft and Hard Tissue Procedures: A Literature Review. Photobiomodul Photomed Laser Surg 2022; 40:522-531. [DOI: 10.1089/photob.2021.0171] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Affiliation(s)
- Agata Lesniewski
- Laboratory of Periodontal-, Implant-, Phototherapy (LA-PIP), Department of Periodontology, School of Dental Medicine, Stony Brook University, Stony Brook, New York, USA
| | - Nathan Estrin
- Laboratory of Periodontal-, Implant-, Phototherapy (LA-PIP), Department of Periodontology, School of Dental Medicine, Stony Brook University, Stony Brook, New York, USA
| | - Georgios E. Romanos
- Laboratory of Periodontal-, Implant-, Phototherapy (LA-PIP), Department of Periodontology, School of Dental Medicine, Stony Brook University, Stony Brook, New York, USA
| |
Collapse
|
8
|
Eid FY, El-Kenany WA, Mowafy MI, El-Kalza AR. The influence of two photobiomodulation protocols on orthodontically induced inflammatory root resorption (a randomized controlled clinical trial). BMC Oral Health 2022; 22:221. [PMID: 35659655 PMCID: PMC9167544 DOI: 10.1186/s12903-022-02251-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2022] [Accepted: 05/27/2022] [Indexed: 11/15/2022] Open
Abstract
Background Controversial results have been reported regarding the impact of photobiomodulation (PBM) on orthodontically induced inflammatory root resorption (OIIRR). The aim of this study was to evaluate the influence of two PBM protocols, one of them requiring a high application frequency (on days 0, 3, 7, 14, then every 2 weeks), while the second requires less frequent applications (every 3 weeks), on OIIRR accompanying orthodontic treatment. Methods Twenty female patients were recruited for this randomized controlled trial, requiring the therapeutic extraction of maxillary first premolars, and they were randomly divided into 2 equal groups. In Group A, one side of the maxillary arch randomly received PBM on days 0, 3, 7, 14, and every 2 weeks thereafter, while in Group B, one side was randomly chosen to receive PBM every 3 weeks. The laser applied was a Diode laser with a wavelength of 980 nm, in a continuous mode. Canine retraction in both groups was carried out using closed-coil springs, delivering 150 g of force, and the force level was checked every 3 weeks, over a 12-week study period. Pre-retraction and post-retraction cone-beam computed tomography (CBCT) was done for the evaluation of OIIRR. Results No significant differences in the amount of OIIRR have been reported between the laser and control sides in both groups A and B. Also, no significant differences have been reported between the laser sides in both groups. Conclusions Photobiomodulation does not affect OIIRR, whether by increasing or decreasing its occurrence, with both laser application protocols. Therefore, it can be stated that PBM does not result in root resorption less than the commonly observed range elicited with conventional orthodontic treatment, and that it has no effect on OIIRR. Trial registration Two Low-level Laser Irradiation Protocols on the Rate of Canine Retraction (NCT04926389), 15/06/2021—retrospectively registered. https://clinicaltrials.gov/ct2/show/NCT04926389.
Collapse
|
9
|
A Novel Concept of Combined High-Level-Laser Treatment and Transcutaneous Photobiomodulation Therapy Utilisation in Orthodontic Periodontal Interface Management. SENSORS 2022; 22:s22062263. [PMID: 35336433 PMCID: PMC8951072 DOI: 10.3390/s22062263] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/16/2022] [Revised: 02/23/2022] [Accepted: 03/14/2022] [Indexed: 02/04/2023]
Abstract
This case report is aimed to demonstrate the synergetic effects of λ940 nm laser photobiomodulation (PBM) therapy in augmenting the advantages of high-level-laser treatment (HLLT)-mediated reaction orthodontic periodontal interface management. Materials and Methods: A 32-year-old female who presented with a persistent gummy smile of upper incisors and low upper midline frenum attachment post-orthodontic treatment, was seeking a better smile appearance. She had a history of delayed wound healing without underlying medical conditions; otherwise, she was fit and healthy. She underwent laser ablation of the upper midline frenum and gingivoplasty of the upper incisors region with λ940 nm and λ2780, respectively, as well as transcutaneous PBM therapy (λ940 nm) to accelerate wound healing. The laser protocols were as follows: λ2780 nm: power output—2 W, pulse width—60 μs, free running pulse (FRP), spot area—0.0016 cm2, pulse repetition rate—25 pulses per second (s), 80 mJ/pulse, 90 s, λ940 nm: 1.2 W, continuous wave (CW) emission mode, 300 μm, 60 s; whereas the adjunctive λ940 nm induced-PBM parameters were as follows: power output—1.4 W, CW—120 s, single application, spot area—2.8 cm2. An acceleration of the wound healing was observed on the 4th day of treatment with no immediate or post-operative complications. The results showed no functional or aesthetic relapses at a long-term follow-up of 6 months. The authors concluded that λ940 nm laser-PBM can provide a synergetic effect to HLLT in accelerating wound healing and offering a precision smile with minimal to none post-operative complications. It is safe and justifiable to utilise dual therapy over the conventional methods, which serves our patients’ needs in our daily practice and in various clinical indications. The concept and laser protocols of this clinical case report can pave the roadmap for future extensive studies.
Collapse
|
10
|
Xu X, Jiang D, Liu G, Mu L, Zeng J, Yang L, He D. In vitro evaluation of the safety and efficacy of a high-power 450-nm semiconductor blue laser in the treatment of benign prostate hyperplasia. Lasers Med Sci 2021; 37:555-561. [PMID: 33770281 DOI: 10.1007/s10103-021-03297-y] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2020] [Accepted: 03/22/2021] [Indexed: 01/17/2023]
Abstract
A 450-nm blue laser may be suitable to treat benign prostate hyperplasia (BPH) due to its haemoglobin absorption characteristic. The present study compared a novel high-power 450-nm semiconductor blue laser with other lasers marketed for in vitro soft tissue ablation, to evaluate the safety and efficacy of the 450-nm laser in BPH surgery. With the in vitro tissues on an experimental platform in water, the vaporization efficiency and coagulation layer thickness of the novel 450-nm laser and commercially available 532-nm, 980-nm, and 1470-nm lasers were measured at the same power (120 W). The damage to the adjacent tissue and the working noise were also measured. The vaporization efficiency was proved to be 450-nm laser > 532-nm laser > 1470-nm laser > 980-nm laser. Comparison of coagulation layer thickness was as follow: 980-nm laser > 1470-nm laser > 532-nm laser > 450-nm laser. The degree of tissue damage caused by the 450-nm and 532-nm lasers increased with the decrease in distance and increase in time (these are safe when a sufficient distance and short irradiation time are maintained). The heating ability of 980-nm and 1470-nm lasers was much greater than that of 450-nm and 532-nm lasers. The working noise was lower in 450-nm and 1470-nm lasers. The novel 450-nm laser has the advantages of highly efficient tissue vaporization, creating a thin coagulation layer, and low working noise. These characteristics suggest that the novel 450-nm laser may be a promising choice for the surgical treatment of BPH.
Collapse
Affiliation(s)
- Xiaofeng Xu
- Department of Urology, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710061, Shaanxi, China
- Department of Urology, Xianyang Central Hospital, Xianyang, 710061, Shaanxi, China
| | - Dali Jiang
- Department of Urology, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710061, Shaanxi, China
| | - Guoxiong Liu
- Department of Urology, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710061, Shaanxi, China
- Department of Urology, Xianyang Central Hospital, Xianyang, 710061, Shaanxi, China
| | - Liyue Mu
- Xi'an Lanji Medical Electronic Technology Co., Ltd., Xi'an, 710003, Shaanxi, China
| | - Jin Zeng
- Department of Urology, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710061, Shaanxi, China
| | - Lin Yang
- Department of Urology, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710061, Shaanxi, China.
| | - Dalin He
- Department of Urology, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710061, Shaanxi, China.
| |
Collapse
|
11
|
Hanke A, Fimmers R, Frentzen M, Meister J. Quantitative determination of cut efficiency during soft tissue surgery using diode lasers in the wavelength range between 400 and 1500 nm. Lasers Med Sci 2021; 36:1633-1647. [PMID: 33496905 PMCID: PMC8433103 DOI: 10.1007/s10103-020-03243-4] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2020] [Accepted: 12/29/2020] [Indexed: 01/19/2023]
Abstract
Within the scope of this ex vivo study, the cut efficiency was investigated with eight diode laser wavelengths in the range from 400 to 1500 nm. Incisions on porcine gingiva samples were generated in CW-mode at a power range of 0.5–4 W using a bare fiber (∅ = 320 μm) in contact and non-contact mode at a cut speed of 2 mm/s. Cut depths, cut widths, and thermal damages were recorded based on histological sections and were evaluated via measurement masks. Moreover, with respect to the controllability of a therapeutic measure, an efficiency factor was defined. At powers above 2 W, for 445 nm, the maximum cut depth was 820 μm and 344 μm for 810 nm, respectively. At all wavelength and power ranges, the cut width averaged 125 μm. At minimum output power (0.5 W), the spatial expansion of the thermal damage in the tissue surface layer corresponds in the blue/green wavelength range from the very beginning of the laser impact to the fiber core diameter. It could be shown that increases in the diode laser power output do not correlate to the same extent with the incision depth nor with thermal damage to tissue.
Collapse
Affiliation(s)
- Amelie Hanke
- Department of Operative and Preventive Dentistry, Bonn University, Welschnonnenstrasse 17, 53111, Bonn, Germany
| | - Rolf Fimmers
- Institute for Medical Biometry, Informatics and Epidemiology (IMBIE), Bonn University, Sigmund-Freud-Strasse 25, 53105, Bonn, Germany
| | - Matthias Frentzen
- Department of Operative and Preventive Dentistry, Bonn University, Welschnonnenstrasse 17, 53111, Bonn, Germany
- Center of Dento-Maxillo-Facial Medicine, Bonn University, Welschnonnenstrasse 17, 53111, Bonn, Germany
| | - Jörg Meister
- Center of Dento-Maxillo-Facial Medicine, Bonn University, Welschnonnenstrasse 17, 53111, Bonn, Germany.
- Center of Applied Medical Laser Research and Biomedical Optics (AMLaReBO), Bonn University, Welschnonnenstrasse 17, 53111, Bonn, Germany.
- Laser Application in Medical Sciences Research Center, Shahid Beheshti University of Medical Sciences, Velenjak Street, 19857-17443, Tehran, Iran.
| |
Collapse
|
12
|
Jurczyszyn K, Trzeciakowski W, Woźniak Z, Ziółkowski P, Trafalski M. Assessment of Effects of Laser Light Combining Three Wavelengths (450, 520 and 640 nm) on Temperature Increase and Depth of Tissue Lesions in an Ex Vivo Study. MATERIALS 2020; 13:ma13235340. [PMID: 33255836 PMCID: PMC7728334 DOI: 10.3390/ma13235340] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/25/2020] [Revised: 11/20/2020] [Accepted: 11/23/2020] [Indexed: 12/30/2022]
Abstract
Background: Lasers are widely used in medicine in soft and hard tissue surgeries and biostimulation. Studies found in literature typically compare the effects of single-wavelength lasers on tissues or cell cultures. In our study, we used a diode laser capable of emitting three components of visible light (640 nm, red; 520 nm, green; 450 nm, blue) and combining them in a single beam. The aim of the study was to assess the effects of laser radiation in the visible spectrum on tissue in vitro, depending on the wavelength and pulse width. Methods: All irradiations were performed using the same output power (1.5 W). We used various duty cycles: 10, 50, 80 and 100% with 100 Hz frequency. Maximum superficial temperature, rate of temperature increase and lesion depth were investigated. Results: Maximum superficial temperature was observed for 450 + 520 nm irradiation (100% duty cycle). The highest rate of increase of temperature was noted for 450 + 520 nm (100% duty cycle). Maximum lesion depth was observed in case of three-wavelength irradiation (450 + 520 + 640 nm) for 100, 80 and 50% duty cycles. Conclusions: The synergistic effect of two-wavelength (450 + 520 nm) irradiation was observed in case of maximum temperature measurement. The deepest depth of lesion was noted after three-wavelength irradiation (450 + 520 + 640 nm).
Collapse
Affiliation(s)
- Kamil Jurczyszyn
- Department of Dental Surgery, Wroclaw Medical University, 50-425 Wroclaw, Poland;
- Correspondence:
| | - Witold Trzeciakowski
- Institute of High Pressure Physics, Polish Academy of Sciences, 01-142 Warsaw, Poland;
| | - Zdzisław Woźniak
- Department of Pathology, Wroclaw Medical University, 50-368 Wroclaw, Poland; (Z.W.); (P.Z.)
| | - Piotr Ziółkowski
- Department of Pathology, Wroclaw Medical University, 50-368 Wroclaw, Poland; (Z.W.); (P.Z.)
| | - Mateusz Trafalski
- Department of Dental Surgery, Wroclaw Medical University, 50-425 Wroclaw, Poland;
| |
Collapse
|
13
|
Fuenmayor P, Quiñonez H, Salas R, Pujadas Z. Experience Treating Earlobe Keloids with Laser Diode 980nm Excision Followed by Triamcinolone Infiltration. Lasers Surg Med 2020; 53:468-475. [PMID: 32827340 DOI: 10.1002/lsm.23310] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2020] [Revised: 07/08/2020] [Accepted: 07/30/2020] [Indexed: 11/10/2022]
Abstract
BACKGROUND AND OBJECTIVE Lasers have a favorable synergistic effect when combined with other modalities of treatment against keloids. Different types of lasers have been used with triamcinolone infiltration, resulting in promising success rates. The purpose of this study is to describe our first experience treating earlobe keloids with 980 nm laser diode excision followed by triamcinolone infiltration and present our outcomes after 24 months of follow-up. STUDY DESIGN/MATERIALS AND METHODS A retrospective chart review of 11 patients with 14 earlobe keloids treated with excision using a 980 nm laser diode followed by triamcinolone acetonide infiltration, between January 2015 and May 2016. Database included demographics, Fitzpatrick skin type, laterality, lesion size, and postoperative visits information. Outcomes were assessed in terms of keloid recurrence rates, complications, and patient subjective aesthetical result satisfaction after 24 months of follow-up. RESULTS All procedures were technically completed, and follow-up accomplished without attrition. One (7.14%) patient experienced keloid recurrence after the third month. Four (28.57%) patients experienced early wound dehiscence, successfully treated with debridement and re-suture. Self-assessment of aesthetical result was considered "very good" in 64.28% of patients. CONCLUSION Surgical excision with 980 nm laser diode followed by triamcinolone infiltration is well-tolerated and shows favorable results treating earlobe keloids, and can be considered a first-line treatment. Comparison between different types of lasers and control groups in large clinical trials is warranted in order to obtain strong clinical evidence for clear indications and recommendations. Lasers Surg. Med. © 2020 Wiley Periodicals LLC.
Collapse
Affiliation(s)
- Pedro Fuenmayor
- Plastic and Reconstructive Surgery Department, Hospital Universitario de Caracas, Universidad Central de Venezuela, Los Chaguaramos, Distrito Capital, Venezuela
| | - Hector Quiñonez
- Plastic and Reconstructive Surgery Department, Hospital Universitario de Caracas, Universidad Central de Venezuela, Los Chaguaramos, Distrito Capital, Venezuela
| | - Reinaldo Salas
- Plastic and Reconstructive Surgery Department, Hospital Universitario de Caracas, Universidad Central de Venezuela, Los Chaguaramos, Distrito Capital, Venezuela
| | - Zoe Pujadas
- Plastic and Reconstructive Surgery Department, Hospital Universitario de Caracas, Universidad Central de Venezuela, Los Chaguaramos, Distrito Capital, Venezuela
| |
Collapse
|
14
|
Varma SR, AlShayeb M, Narayanan J, Abuhijleh E, Hadi A, Jaber M, Abu Fanas S. Applications of Lasers in Refractory Periodontitis: A Narrative Review. J Int Soc Prev Community Dent 2020; 10:384-393. [PMID: 33042878 PMCID: PMC7523935 DOI: 10.4103/jispcd.jispcd_241_20] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2020] [Revised: 05/15/2020] [Accepted: 05/22/2020] [Indexed: 01/17/2023] Open
Abstract
OBJECTIVE The purpose of the study is to evaluate the various lasers in dentistry and to investigate if it can be used for treatment of refractory periodontitis. METHODS The study followed partially the PRISMA guidelines as it is a narrative review. A number of articles were selected from a period of 1980 to 2020 from databases, PubMed, PubMed central, Cochrane and Scopus. Articles related to the effects of lasers on periodontitis both refractory and aggressive were investigated. RESULTS After reviewing the literature, 70 articles were found, related to application of lasers in periodontal diseases. Out of the 70, 11 articles pertained to the effect of laser for the treatment of Refractory and inflammatory periodontitis. 5 articles related to experimental animal models, one pertaining to in-vitro and six studies related to in-vivo in human cohorts. DISCUSSION It was found that lasers if used in controlled parameters by incorporating laser assisted treatment such as Photodynamic therapy and low level laser therapy can be of use as an adjunct therapy for treatment of refractory periodontitis. The use of different wavelengths in the initial and maintenance phase of periodontal disease plays a positive role. The presence of in-vitro and animal model studies is one of the limitation to this study. The available studies have shown marked reduction in inflammation and better clinical and microbiological parameters. The drawback of this study is the limited literature involving laser management for refractory periodontitis in human cohorts. CONCLUSION Different wavelengths of laser and choice of laser assisted periodontal treatment plays an important role in the overall progress and prognosis of periodontal disease activity.
Collapse
Affiliation(s)
- Sudhir Rama Varma
- Department of Periodontics, College of Dentistry, Ajman University, Ajman, UAE
| | - Maher AlShayeb
- Department of Oral Surgery, College of Dentistry, Ajman University, Ajman, UAE
| | - Jayaraj Narayanan
- Department of Basic Sciences, University of Science and Technology of Fujairah, Fujairah, UAE
| | - Eyas Abuhijleh
- Department of Orthodontics, University of Science and Technology, Fujairah, UAE
| | - Abdul Hadi
- Department of Restorative Dentistry, University of Science and Technology, Fujairah, UAE
| | - Mohammad Jaber
- Department of Oral Surgery, College of Dentistry, Ajman University, Ajman, UAE
| | - Salim Abu Fanas
- Department of Periodontics, College of Dentistry, Ajman University, Ajman, UAE
| |
Collapse
|
15
|
Comparison of A 1940 nm Thulium-Doped Fiber Laser and A 1470 nm Diode Laser for Cutting Efficacy and Hemostasis in A Pig Model of Spleen Surgery. MATERIALS 2020; 13:ma13051167. [PMID: 32151086 PMCID: PMC7085013 DOI: 10.3390/ma13051167] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/01/2020] [Revised: 02/28/2020] [Accepted: 03/02/2020] [Indexed: 01/19/2023]
Abstract
Partial and total splenectomies are associated with a high risk of substantial blood loss. Lasers operating at wavelengths strongly absorbed by water have the potential to improve hemostasis and cut while providing a narrow zone of thermal damage. The aim of this study is to compare a thulium-doped fiber laser (TDFL) emitting a wavelength of 1940 nm and a diode laser (DL) operating at 1470 nm for spleen surgery in a pig model. A partial splenectomy and spleen incisions were made in 12 animals using the two laser devices. The hemostasis was evaluated visually during surgeries. Post-mortem and histopathological evaluations were done on days 0, 7, and 14 following surgery. Neither TDFL nor DL caused bleeding on day 0 or delayed bleeding. On day 14, pale streaks at the site of incision were slightly wider after cutting with DL than with TDFL. Histological analysis revealed a carbonized zone with exudation and a deeper zone of thermal tissue damage on day 0. The width of the thermal changes was 655.26 ± 107.70 μm for TDFL and 1413.37 ± 111.85 μm for DL. On day 7, a proliferation of fibroblasts and splenocytes was visible, as well as a formation of multinucleated giant cells adjacent to the residues of carbonization. The zone of thermal damage was broader for DL (1157.5 ± 262.77 μm) than for TDFL (682.22 ± 116.58 μm). On day 14, cutting sites were filled with connective and granulation tissues with the residues of carbonization. The zone of thermal damage was narrower for TDFL (761.65 ± 34.3 μm) than for DL (1609.82 ± 202.22 μm). Thus, both lasers are efficient in spleen surgery, providing good hemostasis. However, TDFL produces a narrower zone of thermal damage, which suggests its better efficiency for spleen surgery, especially when performing more precise procedures.
Collapse
|
16
|
Gutiérrez-Corrales A, Rizcala-Orlando Y, Montero-Miralles P, Volland G, Gutiérrez-Pérez JL, Torres-Lagares D, Serrera-Figallo MA. Comparison of diode laser - Oral tissue interaction to different wavelengths. In vitro study of porcine periodontal pockets and oral mucosa. Med Oral Patol Oral Cir Bucal 2020; 25:e224-e232. [PMID: 31967980 PMCID: PMC7103451 DOI: 10.4317/medoral.23317] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2019] [Accepted: 07/11/2019] [Indexed: 12/20/2022] Open
Abstract
Background The aim of this in vitro study was to evaluate the effect of diode lasers at different wavelengths and power settings in handmade incisions in periodontal pockets and in oral mucosa of porcine tissue considering thermal damage, necrosis and the affected area of the soft tissue.
Material and Methods Combining the following laser wavelengths, 445nm, 532nm (KTP), 810nm, 980nm, 1064nm and 1470nm, and a power range from 0.5W to 2.0W in a continuous wave mode (CW), we made handmade incisions in porcine periodontal pockets and oral mucosa. After histological processing, we measured the area of lost tissue, the area of thermal damage and the area of necrosis. Then, we performed ANOVA to evaluate the difference between groups and two-way ANOVA to identify the influence of the laser-type variables and the power on the results.
Results We applied an ANOVA test to evaluate the results, where statistical analysis showed clear differences between the 1470nm and 810nm laser groups that refer to thermal damage and necrosis in the periodontal pocket surface. Regarding the oral mucosa surface, the 1064nm laser showed differences in the analysis of lost tissue. According to the applied power, all the variables we studied (lost tissue area, area of thermal damage and necrosis) showed higher values when using a power of 2.0W instead of 0.5W.
Conclusions According to our results, the 810nm diode laser for oral soft-tissue biopsy using power ranges between 0.5W and 2W would be the best choice to avoid thermal damage in peri-incisional margins. Key words:Laser surgery, soft tissue, diode laser, KTP laser, thermal damage, necrosis.
Collapse
|
17
|
Tamburro R, Brunetti B, Muscatello LV, Mantovani C, De Lorenzi D. Short-term surgical outcomes and histomorphological evaluation of thermal injury following palatoplasty performed with diode laser or air plasma device in dogs with brachycephalic airway obstructive syndrome. Vet J 2019; 253:105391. [PMID: 31685136 DOI: 10.1016/j.tvjl.2019.105391] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2018] [Revised: 09/21/2019] [Accepted: 09/21/2019] [Indexed: 10/26/2022]
Abstract
Brachycephalic obstructive airway syndrome (BOAS) is a common disorder presenting enlarged soft palate, stenotic nares and abnormal turbinate growth. Surgical correction of BOAS abnormalities with caudal palatoplasty is an elective therapy. This prospective study aimed to compare the effect of an air plasma device and diode laser in dogs undergoing palatoplasty. Outcome measures were as follows: (1) intra-operative and immediate post-operative complications; (2) evaluation of thermal injury in histological tissue sections of the excised soft palate. Twenty dogs with enlarged soft palates underwent palatoplasty, using an air plasma device (n=10) and diode laser (n=10). Soft palate specimens underwent masked histopathological analysis to assess post-operative thermal injury. In this pilot study, no differences were observed in surgical times; all dogs were discharged 24h after surgery and had stable respiration. In the air plasma group, post-operative bleeding occurred in two cases and revision surgery was performed. No difference in thermal injury was observed using the two devices (P>0.05). The air-plasma device was a viable surgical option for palatoplasty in dogs with BOAS.
Collapse
Affiliation(s)
- R Tamburro
- University of Teramo, School of Veterinary Medicine, Località Piano d'Accio, 64100 Teramo, Italy.
| | - B Brunetti
- University of Bologna, Department of Veterinary Medical Sciences, via Tolara di Sopra 50, Ozzano Emilia, 40064 Bologna, Italy
| | - L V Muscatello
- University of Bologna, Department of Veterinary Medical Sciences, via Tolara di Sopra 50, Ozzano Emilia, 40064 Bologna, Italy
| | - C Mantovani
- Veterinary Hospital "I Portoni Rossi", via Roma 57, Zola Predosa, 40069 Bologna, Italy
| | - D De Lorenzi
- Veterinary Hospital "I Portoni Rossi", via Roma 57, Zola Predosa, 40069 Bologna, Italy
| |
Collapse
|
18
|
Fornaini C, Merigo E, Poli F, Cavatorta C, Rocca JP, Selleri S, Cucinotta A. Use of 1070 nm fiber lasers in oral surgery: preliminary ex vivo study with FBG temperature monitoring. Laser Ther 2017; 26:311-318. [PMID: 29434432 PMCID: PMC5801457 DOI: 10.5978/islsm.17-or-21] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2017] [Accepted: 09/12/2017] [Indexed: 12/12/2022]
Abstract
BACKGROUND AND AIMS The aim of this ex vivo study was to demonstrate the performances of 1070 nm fiber lasers for the ablation of oral tissues through the evaluation of the histological modifications made by a blind pathologist and the measurement of the thermal elevation during laser irradiation by a sensor based on a fiber Bragg grating. MATERIALS AND METHODS The source used was a pulsed fiber laser emitting at 1070 nm, with 20 W maximum average output power and 100 ns fixed pulse duration. Different tests were performed by changing the laser parameters, particularly the peak power of the pulses and the repetition rate. RESULTS The tissue of the measurements demonstrated that the best properties in term of cutting capability and, at the same time, the lower thermal damages to the tissues can be obtained with a peak power of 3 kW, a repetition rate of 50 kHz and a speed of 5 mm/s. CONCLUSIONS This ex vivo study showed that 1070 nm fiber lasers can be very useful in oral surgery, since they provide a reduced thermal elevation in the irradiated tissues, thus consequently respecting their biological structures. Moreover, this work demonstrates that FBG sensors, based on the optical fiber technology as the laser source considered for the tests, may be good instruments to record thermal elevation when applied to the ex vivo studies on animal models.
Collapse
Affiliation(s)
- Carlo Fornaini
- Department of Engineering and Architecture, University of Parma, Parco Area delle Scienze 181/A, 43124 Parma, Italy
- Micoralis Laboratory, Faculty of Dentistry, University of Cote d'Azur, 24 Avenue des Diables Bleus, 06357 Nice, France
| | - Elisabetta Merigo
- Micoralis Laboratory, Faculty of Dentistry, University of Cote d'Azur, 24 Avenue des Diables Bleus, 06357 Nice, France
| | - Federica Poli
- Department of Engineering and Architecture, University of Parma, Parco Area delle Scienze 181/A, 43124 Parma, Italy
| | - Chiara Cavatorta
- Section of Pathologic Anatomy, University Clinic Policlinico of Modena, Via del Pozzo 71 - 41124 Modena, Italy
| | - Jean-Paul Rocca
- Section of Pathologic Anatomy, University Clinic Policlinico of Modena, Via del Pozzo 71 - 41124 Modena, Italy
| | - Stefano Selleri
- Department of Engineering and Architecture, University of Parma, Parco Area delle Scienze 181/A, 43124 Parma, Italy
| | - Annamaria Cucinotta
- Department of Engineering and Architecture, University of Parma, Parco Area delle Scienze 181/A, 43124 Parma, Italy
| |
Collapse
|