1
|
Rocchitta G, Spanu A, Babudieri S, Latte G, Madeddu G, Galleri G, Nuvoli S, Bagella P, Demartis MI, Fiore V, Manetti R, Serra PA. Enzyme Biosensors for Biomedical Applications: Strategies for Safeguarding Analytical Performances in Biological Fluids. SENSORS 2016; 16:s16060780. [PMID: 27249001 PMCID: PMC4934206 DOI: 10.3390/s16060780] [Citation(s) in RCA: 225] [Impact Index Per Article: 28.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/13/2016] [Revised: 05/06/2016] [Accepted: 05/24/2016] [Indexed: 12/22/2022]
Abstract
Enzyme-based chemical biosensors are based on biological recognition. In order to operate, the enzymes must be available to catalyze a specific biochemical reaction and be stable under the normal operating conditions of the biosensor. Design of biosensors is based on knowledge about the target analyte, as well as the complexity of the matrix in which the analyte has to be quantified. This article reviews the problems resulting from the interaction of enzyme-based amperometric biosensors with complex biological matrices containing the target analyte(s). One of the most challenging disadvantages of amperometric enzyme-based biosensor detection is signal reduction from fouling agents and interference from chemicals present in the sample matrix. This article, therefore, investigates the principles of functioning of enzymatic biosensors, their analytical performance over time and the strategies used to optimize their performance. Moreover, the composition of biological fluids as a function of their interaction with biosensing will be presented.
Collapse
Affiliation(s)
- Gaia Rocchitta
- Department of Clinical and Experimental Medicine, Medical School, University of Sassari, Viale S. Pietro 43/b, Sassari 07100, Italy.
| | - Angela Spanu
- Department of Clinical and Experimental Medicine, Medical School, University of Sassari, Viale S. Pietro 43/b, Sassari 07100, Italy.
| | - Sergio Babudieri
- Department of Clinical and Experimental Medicine, Medical School, University of Sassari, Viale S. Pietro 43/b, Sassari 07100, Italy.
| | - Gavinella Latte
- Department of Clinical and Experimental Medicine, Medical School, University of Sassari, Viale S. Pietro 43/b, Sassari 07100, Italy.
| | - Giordano Madeddu
- Department of Clinical and Experimental Medicine, Medical School, University of Sassari, Viale S. Pietro 43/b, Sassari 07100, Italy.
| | - Grazia Galleri
- Department of Clinical and Experimental Medicine, Medical School, University of Sassari, Viale S. Pietro 43/b, Sassari 07100, Italy.
| | - Susanna Nuvoli
- Department of Clinical and Experimental Medicine, Medical School, University of Sassari, Viale S. Pietro 43/b, Sassari 07100, Italy.
| | - Paola Bagella
- Department of Clinical and Experimental Medicine, Medical School, University of Sassari, Viale S. Pietro 43/b, Sassari 07100, Italy.
| | - Maria Ilaria Demartis
- Department of Clinical and Experimental Medicine, Medical School, University of Sassari, Viale S. Pietro 43/b, Sassari 07100, Italy.
| | - Vito Fiore
- Department of Clinical and Experimental Medicine, Medical School, University of Sassari, Viale S. Pietro 43/b, Sassari 07100, Italy.
| | - Roberto Manetti
- Department of Clinical and Experimental Medicine, Medical School, University of Sassari, Viale S. Pietro 43/b, Sassari 07100, Italy.
| | - Pier Andrea Serra
- Department of Clinical and Experimental Medicine, Medical School, University of Sassari, Viale S. Pietro 43/b, Sassari 07100, Italy.
| |
Collapse
|
2
|
Dzyadevych S, Arkhypova V, Soldatkin A, El'skaya A, Martelet C, Jaffrezic-Renault N. Amperometric enzyme biosensors: Past, present and future. Ing Rech Biomed 2008. [DOI: 10.1016/j.rbmret.2007.11.007] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
3
|
Dzyadevych SV. Conductometric enzyme biosensors: theory, technology, application. ACTA ACUST UNITED AC 2005. [DOI: 10.7124/bc.0006e1] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Affiliation(s)
- S. V. Dzyadevych
- Institute of Molecular Biology and Genetics, National Academy of Sciences of Ukraine
| |
Collapse
|
4
|
Danyleyko LV, Schuvailo ON, Arkhypova VM, Soldatkin AP, Dzyadevych SV. Development of amperometric enzyme biosensor based on carbon fibre electrode and immobilized glucose oxidase. ACTA ACUST UNITED AC 2003. [DOI: 10.7124/bc.00063e] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Affiliation(s)
- L. V. Danyleyko
- Institute of Molecular Biology and Genetics, National Academy of Sciences of Ukraine
| | - O. N. Schuvailo
- Institute of Molecular Biology and Genetics, National Academy of Sciences of Ukraine
| | - V. M. Arkhypova
- Institute of Molecular Biology and Genetics, National Academy of Sciences of Ukraine
| | - A. P. Soldatkin
- Institute of Molecular Biology and Genetics, National Academy of Sciences of Ukraine
| | - S. V. Dzyadevych
- Institute of Molecular Biology and Genetics, National Academy of Sciences of Ukraine
| |
Collapse
|
5
|
Dzyadevych SV. Amperometric biosensors. Modern technologies and commercial variants. ACTA ACUST UNITED AC 2002. [DOI: 10.7124/bc.00061a] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Affiliation(s)
- S. V. Dzyadevych
- Institute of Molecular Biology and Genetics, National Academy of Sciences of Ukraine
| |
Collapse
|