1
|
Yadav S, Vinothkumar KR. Factors affecting macromolecule orientations in thin films formed in cryo-EM. Acta Crystallogr D Struct Biol 2024; 80:535-550. [PMID: 38935342 PMCID: PMC11220838 DOI: 10.1107/s2059798324005229] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Accepted: 06/01/2024] [Indexed: 06/28/2024] Open
Abstract
The formation of a vitrified thin film embedded with randomly oriented macromolecules is an essential prerequisite for cryogenic sample electron microscopy. Most commonly, this is achieved using the plunge-freeze method first described nearly 40 years ago. Although this is a robust method, the behaviour of different macromolecules shows great variation upon freezing and often needs to be optimized to obtain an isotropic, high-resolution reconstruction. For a macromolecule in such a film, the probability of encountering the air-water interface in the time between blotting and freezing and adopting preferred orientations is very high. 3D reconstruction using preferentially oriented particles often leads to anisotropic and uninterpretable maps. Currently, there are no general solutions to this prevalent issue, but several approaches largely focusing on sample preparation with the use of additives and novel grid modifications have been attempted. In this study, the effect of physical and chemical factors on the orientations of macromolecules was investigated through an analysis of selected well studied macromolecules, and important parameters that determine the behaviour of proteins on cryo-EM grids were revealed. These insights highlight the nature of the interactions that cause preferred orientations and can be utilized to systematically address orientation bias for any given macromolecule and to provide a framework to design small-molecule additives to enhance sample stability and behaviour.
Collapse
Affiliation(s)
- Swati Yadav
- National Centre for Biological SciencesTata Institute of Fundamental ResearchGKVK Post, Bellary RoadBengaluru560 065India
| | - Kutti R. Vinothkumar
- National Centre for Biological SciencesTata Institute of Fundamental ResearchGKVK Post, Bellary RoadBengaluru560 065India
| |
Collapse
|
2
|
Hirst IJ, Thomas WJ, Davies RA, Muench SP. CryoEM grid preparation: a closer look at advancements and impact of preparation mode and new approaches. Biochem Soc Trans 2024; 52:1529-1537. [PMID: 38864435 PMCID: PMC11346429 DOI: 10.1042/bst20231553] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2024] [Revised: 05/30/2024] [Accepted: 06/03/2024] [Indexed: 06/13/2024]
Abstract
Sample preparation can present a significant hurdle within single particle cryo-electron microscopy (cryoEM), resulting in issues with reproducibility, data quality or an inability to visualise the sample. There are several factors which can influence this, including sample or buffer composition, grid type, route of sample preparation and interactions with the air-water interface (AWI). Here, we review some of the current routes for sample preparation and the associated challenges. We discuss a range of approaches for overcoming these challenges, such as minimising the grid preparation time, surfactants, grid type and biochemical approaches such as nanomagnetic beads. Finally, we discuss how a set of commercially available protein samples may serve as a benchmark suite for future technologies. This provides a route to compare techniques' abilities not just to generate high-resolution structures but also to overcome the challenges traditionally associated with cryoEM. As the field continues to produce new approaches to sample preparation and we start to better understand the underlying principles behind the behaviour of proteins within a thin film and in response to different environments, especially grid composition, it is hoped that more universal solutions can be provided that make the intractable systems tractable, improve resolution and, importantly, speed up data collection and reduce the currently required dataset sizes.
Collapse
Affiliation(s)
- Isobel J. Hirst
- School of Biomedical Sciences, Faculty of Biological Sciences, University of Leeds, Leeds LS2 9JT, U.K
- Astbury Centre for Structural Molecular Biology, University of Leeds, Leeds LS2 9JT, U.K
| | - William J.R. Thomas
- School of Biomedical Sciences, Faculty of Biological Sciences, University of Leeds, Leeds LS2 9JT, U.K
- Astbury Centre for Structural Molecular Biology, University of Leeds, Leeds LS2 9JT, U.K
| | - Rhiannon A. Davies
- School of Biomedical Sciences, Faculty of Biological Sciences, University of Leeds, Leeds LS2 9JT, U.K
- Astbury Centre for Structural Molecular Biology, University of Leeds, Leeds LS2 9JT, U.K
| | - Stephen P. Muench
- School of Biomedical Sciences, Faculty of Biological Sciences, University of Leeds, Leeds LS2 9JT, U.K
- Astbury Centre for Structural Molecular Biology, University of Leeds, Leeds LS2 9JT, U.K
| |
Collapse
|
3
|
Xu J, Gao X, Zheng L, Jia X, Xu K, Ma Y, Wei X, Liu N, Peng H, Wang HW. Graphene sandwich-based biological specimen preparation for cryo-EM analysis. Proc Natl Acad Sci U S A 2024; 121:e2309384121. [PMID: 38252835 PMCID: PMC10835136 DOI: 10.1073/pnas.2309384121] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2023] [Accepted: 12/20/2023] [Indexed: 01/24/2024] Open
Abstract
High-quality specimen preparation plays a crucial role in cryo-electron microscopy (cryo-EM) structural analysis. In this study, we have developed a reliable and convenient technique called the graphene sandwich method for preparing cryo-EM specimens. This method involves using two layers of graphene films that enclose macromolecules on both sides, allowing for an appropriate ice thickness for cryo-EM analysis. The graphene sandwich helps to mitigate beam-induced charging effect and reduce particle motion compared to specimens prepared using the traditional method with graphene support on only one side, therefore improving the cryo-EM data quality. These advancements may open new opportunities to expand the use of graphene in the field of biological electron microscopy.
Collapse
Affiliation(s)
- Jie Xu
- Ministry of Education Key Laboratory of Protein Sciences, Beijing Frontier Research Center for Biological Structure, Beijing Advanced Innovation Center for Structural Biology, School of Life Sciences, Tsinghua University, Beijing100084, China
- Tsinghua-Peking Center for Life Sciences, School of Life Sciences, Tsinghua University, Beijing100084, China
| | - Xiaoyin Gao
- Beijing National Laboratory for Molecular Sciences, College of Chemistry and Molecular Engineering, Peking University, Beijing100871, China
| | - Liming Zheng
- Beijing National Laboratory for Molecular Sciences, College of Chemistry and Molecular Engineering, Peking University, Beijing100871, China
| | - Xia Jia
- Ministry of Education Key Laboratory of Protein Sciences, Beijing Frontier Research Center for Biological Structure, Beijing Advanced Innovation Center for Structural Biology, School of Life Sciences, Tsinghua University, Beijing100084, China
- Tsinghua-Peking Center for Life Sciences, School of Life Sciences, Tsinghua University, Beijing100084, China
| | - Kui Xu
- Ministry of Education Key Laboratory of Protein Sciences, Beijing Frontier Research Center for Biological Structure, Beijing Advanced Innovation Center for Structural Biology, School of Life Sciences, Tsinghua University, Beijing100084, China
- Tsinghua-Peking Center for Life Sciences, School of Life Sciences, Tsinghua University, Beijing100084, China
| | - Yuwei Ma
- State Key Laboratory for Turbulence and Complex System, Department of Mechanics and Engineering Science, College of Engineering, Peking University, Beijing100871, China
| | - Xiaoding Wei
- State Key Laboratory for Turbulence and Complex System, Department of Mechanics and Engineering Science, College of Engineering, Peking University, Beijing100871, China
| | - Nan Liu
- Ministry of Education Key Laboratory of Protein Sciences, Beijing Frontier Research Center for Biological Structure, Beijing Advanced Innovation Center for Structural Biology, School of Life Sciences, Tsinghua University, Beijing100084, China
| | - Hailin Peng
- Beijing National Laboratory for Molecular Sciences, College of Chemistry and Molecular Engineering, Peking University, Beijing100871, China
- Beijing Graphene Institute, Beijing100095, China
- Academy for Advanced Interdisciplinary Studies, Peking University, Beijing100871, China
| | - Hong-Wei Wang
- Ministry of Education Key Laboratory of Protein Sciences, Beijing Frontier Research Center for Biological Structure, Beijing Advanced Innovation Center for Structural Biology, School of Life Sciences, Tsinghua University, Beijing100084, China
- Tsinghua-Peking Center for Life Sciences, School of Life Sciences, Tsinghua University, Beijing100084, China
| |
Collapse
|
4
|
Xu Y, Qin Y, Wang L, Zhang Y, Wang Y, Dang S. Metallo-supramolecular branched polymer protects particles from air-water interface in single-particle cryo-electron microscopy. Commun Biol 2024; 7:65. [PMID: 38195919 PMCID: PMC10776832 DOI: 10.1038/s42003-023-05752-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2023] [Accepted: 12/28/2023] [Indexed: 01/11/2024] Open
Abstract
Recent technological breakthroughs in single-particle cryo-electron microscopy (cryo-EM) enable rapid atomic structure determination of biological macromolecules. A major bottleneck in the current single particle cryo-EM pipeline is the preparation of good quality frozen cryo-EM grids, which is mostly a trial-and-error process. Among many issues, preferred particle orientation and sample damage by air-water interface (AWI) are common practical problems. Here we report a method of applying metallo-supramolecular branched polymer (MSBP) in the cryo-sample preparation for high-resolution single-particle cryo-EM. Our data shows that MSBP keeps a majority of particles away from air-water interface and mitigates preferred orientation as verified by the analyses of apoferritin, hemagglutinin) trimer and various sample proteins. The use of MSBP is a simple method to improve particle distribution for high-resolution structure determination in single-particle cryo-EM.
Collapse
Affiliation(s)
- Yixin Xu
- Division of Life Science, The Hong Kong University of Science and Technology, Clear Water Bay, Hong Kong, China
- Department of Biology, Institute of Molecular Biology and Biophysics, ETH Zurich, Zurich, Switzerland
| | - Yuqi Qin
- Division of Life Science, The Hong Kong University of Science and Technology, Clear Water Bay, Hong Kong, China
| | - Lang Wang
- Department of Chemistry, The University of Hong Kong, Hong Kong, China
| | - Yingyi Zhang
- Biological Cryo-EM Center, The Hong Kong University of Science and Technology, Clear Water Bay, Hong Kong, China
| | - Yufeng Wang
- Department of Chemistry, The University of Hong Kong, Hong Kong, China.
| | - Shangyu Dang
- Division of Life Science, The Hong Kong University of Science and Technology, Clear Water Bay, Hong Kong, China.
- Southern Marine Science and Engineering Guangdong Laboratory (Guangzhou), Guangzhou, China.
- HKUST-Shenzhen Research Institute, Nanshan, Shenzhen, China.
| |
Collapse
|
5
|
Klebl DP, Aspinall L, Muench SP. Time resolved applications for Cryo-EM; approaches, challenges and future directions. Curr Opin Struct Biol 2023; 83:102696. [PMID: 37716094 DOI: 10.1016/j.sbi.2023.102696] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Revised: 06/14/2023] [Accepted: 08/14/2023] [Indexed: 09/18/2023]
Abstract
Developments within the cryo-EM field have allowed us to generate higher-resolution "static" structures and pull out different conformational states which exist at equilibrium within the sample. Moreover, to trap non-equilibrium states and determine conformations that are present after a defined period of time (typically in the ms time frame) new approaches have been developed for the application of time-resolved cryo-EM. Here we give an overview of these different approaches and the limitations and strengths of each whilst identifying some of the current challenges to achieve higher resolutions and trap states within faster time frames. Time-resolved applications may play an important role in the ever-expanding toolkit of cryo-EM and open up new possibilities in both single particle and tomographic studies.
Collapse
Affiliation(s)
- David P Klebl
- School of Biomedical Sciences, Astbury Centre for Structural Molecular Biology, University of Leeds, UK
| | - Louie Aspinall
- School of Molecular and Cellular Biology, University of Leeds, UK
| | - Stephen P Muench
- School of Biomedical Sciences, Astbury Centre for Structural Molecular Biology, University of Leeds, UK.
| |
Collapse
|
6
|
Lee D, Lee H, Lee J, Roh SH, Ha NC. Copper Oxide Spike Grids for Enhanced Solution Transfer in Cryogenic Electron Microscopy. Mol Cells 2023; 46:538-544. [PMID: 37528647 PMCID: PMC10495688 DOI: 10.14348/molcells.2023.0058] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2023] [Revised: 06/27/2023] [Accepted: 06/27/2023] [Indexed: 08/03/2023] Open
Abstract
The formation of uniform vitreous ice is a crucial step in the preparation of samples for cryogenic electron microscopy (cryo-EM). Despite the rapid technological progress in EM, controlling the thickness of vitreous ice on sample grids with reproducibility remains a major obstacle to obtaining high-quality data in cryo-EM imaging. The commonly employed classical blotting process faces the problem of excess water that cannot be absorbed by the filter paper, resulting in the formation of thick and heterogeneous ice. In this study, we propose a novel approach that combines the recently developed nanowire self-wicking technique with the classical blotting method to effectively control the thickness and homogeneity of vitrified ice. With simple procedures, we generated a copper oxide spike (COS) grid by inducing COSs on commercially available copper grids, which can effectively remove excess water during the blotting procedure without damaging the holey carbon membrane. The ice thickness could be controlled with good reproducibility compared to non-oxidized grids. Incorporated into other EM techniques, our new modification method is an effective option for obtaining high-quality data during cryo-EM imaging.
Collapse
Affiliation(s)
- Dukwon Lee
- Research Institute of Agriculture and Life Sciences, Center for Food and Bioconvergence, Department of Agricultural Biotechnology, Interdisciplinary Programs in Agricultural Genomics, College of Agriculture and Life Sciences (CALS), Seoul National University, Seoul 08826, Korea
| | - Hansol Lee
- School of Biological Sciences, Seoul National University, Seoul 08826, Korea
- Institute of Molecular Biology and Genetics, Seoul National University, Seoul 08826, Korea
| | - Jinwook Lee
- Research Institute of Agriculture and Life Sciences, Center for Food and Bioconvergence, Department of Agricultural Biotechnology, Interdisciplinary Programs in Agricultural Genomics, College of Agriculture and Life Sciences (CALS), Seoul National University, Seoul 08826, Korea
| | - Soung-Hun Roh
- School of Biological Sciences, Seoul National University, Seoul 08826, Korea
- Institute of Molecular Biology and Genetics, Seoul National University, Seoul 08826, Korea
| | - Nam-Chul Ha
- Research Institute of Agriculture and Life Sciences, Center for Food and Bioconvergence, Department of Agricultural Biotechnology, Interdisciplinary Programs in Agricultural Genomics, College of Agriculture and Life Sciences (CALS), Seoul National University, Seoul 08826, Korea
| |
Collapse
|
7
|
Han BG, Avila-Sakar A, Remis J, Glaeser RM. Challenges in making ideal cryo-EM samples. Curr Opin Struct Biol 2023; 81:102646. [PMID: 37392555 DOI: 10.1016/j.sbi.2023.102646] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2022] [Revised: 06/02/2023] [Accepted: 06/02/2023] [Indexed: 07/03/2023]
Abstract
Recognizing that interaction with the air-water interface (AWI) is a major challenge for cryo-EM, we first review current approaches designed to avoid it. Of these, immobilizing particles on affinity grids is arguably the most promising. In addition, we review efforts to gain more reliable control of the sample thicknesses, not the least important reason being to prevent immobilized particles from coming in contact with the AWI of the remaining buffer. It is emphasized that avoiding such a contact is as important for cryo-ET as for single-particle cryo-EM. Finally, looking to the future, it is proposed that immobilized samples might be used to perform time-resolved biochemical experiments directly on EM grids rather than just in test tubes or cuvettes.
Collapse
Affiliation(s)
- Bong-Gyoon Han
- Lawrence Berkeley National Laboratory, University of California, Berkeley, CA 94720, USA
| | - Agustin Avila-Sakar
- Lawrence Berkeley National Laboratory, University of California, Berkeley, CA 94720, USA
| | - Jonathan Remis
- Department of Physics, University of California, Berkeley, CA 94720, USA
| | - Robert M Glaeser
- Lawrence Berkeley National Laboratory, University of California, Berkeley, CA 94720, USA.
| |
Collapse
|
8
|
Vasina M, Kovar D, Damborsky J, Ding Y, Yang T, deMello A, Mazurenko S, Stavrakis S, Prokop Z. In-depth analysis of biocatalysts by microfluidics: An emerging source of data for machine learning. Biotechnol Adv 2023; 66:108171. [PMID: 37150331 DOI: 10.1016/j.biotechadv.2023.108171] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2023] [Revised: 05/04/2023] [Accepted: 05/04/2023] [Indexed: 05/09/2023]
Abstract
Nowadays, the vastly increasing demand for novel biotechnological products is supported by the continuous development of biocatalytic applications which provide sustainable green alternatives to chemical processes. The success of a biocatalytic application is critically dependent on how quickly we can identify and characterize enzyme variants fitting the conditions of industrial processes. While miniaturization and parallelization have dramatically increased the throughput of next-generation sequencing systems, the subsequent characterization of the obtained candidates is still a limiting process in identifying the desired biocatalysts. Only a few commercial microfluidic systems for enzyme analysis are currently available, and the transformation of numerous published prototypes into commercial platforms is still to be streamlined. This review presents the state-of-the-art, recent trends, and perspectives in applying microfluidic tools in the functional and structural analysis of biocatalysts. We discuss the advantages and disadvantages of available technologies, their reproducibility and robustness, and readiness for routine laboratory use. We also highlight the unexplored potential of microfluidics to leverage the power of machine learning for biocatalyst development.
Collapse
Affiliation(s)
- Michal Vasina
- Loschmidt Laboratories, Department of Experimental Biology and RECETOX, Faculty of Science, Masaryk University, 602 00 Brno, Czech Republic; International Clinical Research Centre, St. Anne's University Hospital, 656 91 Brno, Czech Republic
| | - David Kovar
- Loschmidt Laboratories, Department of Experimental Biology and RECETOX, Faculty of Science, Masaryk University, 602 00 Brno, Czech Republic; International Clinical Research Centre, St. Anne's University Hospital, 656 91 Brno, Czech Republic
| | - Jiri Damborsky
- Loschmidt Laboratories, Department of Experimental Biology and RECETOX, Faculty of Science, Masaryk University, 602 00 Brno, Czech Republic; International Clinical Research Centre, St. Anne's University Hospital, 656 91 Brno, Czech Republic
| | - Yun Ding
- Institute for Chemical and Bioengineering, ETH Zürich, 8093 Zürich, Switzerland
| | - Tianjin Yang
- Institute for Chemical and Bioengineering, ETH Zürich, 8093 Zürich, Switzerland; Department of Biochemistry, University of Zurich, 8057 Zurich, Switzerland
| | - Andrew deMello
- Institute for Chemical and Bioengineering, ETH Zürich, 8093 Zürich, Switzerland
| | - Stanislav Mazurenko
- Loschmidt Laboratories, Department of Experimental Biology and RECETOX, Faculty of Science, Masaryk University, 602 00 Brno, Czech Republic; International Clinical Research Centre, St. Anne's University Hospital, 656 91 Brno, Czech Republic.
| | - Stavros Stavrakis
- Institute for Chemical and Bioengineering, ETH Zürich, 8093 Zürich, Switzerland.
| | - Zbynek Prokop
- Loschmidt Laboratories, Department of Experimental Biology and RECETOX, Faculty of Science, Masaryk University, 602 00 Brno, Czech Republic; International Clinical Research Centre, St. Anne's University Hospital, 656 91 Brno, Czech Republic.
| |
Collapse
|
9
|
Hall M, Schexnaydre E, Holmlund C, Carroni M. Protein Structural Analysis by Cryogenic Electron Microscopy. Methods Mol Biol 2023; 2652:439-463. [PMID: 37093490 DOI: 10.1007/978-1-0716-3147-8_24] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/25/2023]
Abstract
Cryogenic electron microscopy (cryo-EM) is constantly developing and growing as a major technique for structure determination of protein complexes. Here, we detail the first steps of any cryo-EM project: specimen preparation and data collection. Step by step, a list of material needed is provided and the sequence of actions to carry out is given. We hope that these protocols will be useful to all people getting started with cryo-EM.
Collapse
Affiliation(s)
- Michael Hall
- SciLifeLab Cryo-EM Facility, Department of Chemistry, Umeå University, Umeå, Sweden.
| | - Erin Schexnaydre
- SciLifeLab Cryo-EM Facility, Department of Chemistry, Umeå University, Umeå, Sweden
| | - Camilla Holmlund
- SciLifeLab Cryo-EM Facility, Department of Chemistry, Umeå University, Umeå, Sweden
| | - Marta Carroni
- SciLifeLab Cryo-EM Facility, Department of Biochemistry and Biophysics, Stockholm University, Solna, Sweden.
| |
Collapse
|
10
|
Liu N, Wang HW. Better Cryo-EM Specimen Preparation: How to Deal with the Air-Water Interface? J Mol Biol 2022; 435:167926. [PMID: 36563741 DOI: 10.1016/j.jmb.2022.167926] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2022] [Revised: 12/08/2022] [Accepted: 12/14/2022] [Indexed: 12/24/2022]
Abstract
Cryogenic electron microscopy (cryo-EM) is now one of the most powerful and widely used methods to determine high-resolution structures of macromolecules. A major bottleneck of cryo-EM is to prepare high-quality vitrified specimen, which still faces many practical challenges. During the conventional vitrification process, macromolecules tend to adsorb at the air-water interface (AWI), which is known unfriendly to biological samples. In this review, we outline the nature of AWI and the problems caused by it, such as unpredictable or uneven particle distribution, protein denaturation, dissociation of complex and preferential orientation. We review and discuss the approaches and underlying mechanisms to deal with AWI: 1) Additives, exemplified by detergents, forming a protective layer at AWI and thus preserving the native folds of target macromolecules. 2) Fast vitrification devices based on the idea to freeze in-solution macromolecules before their touching of AWI. 3) Thin layer of continuous supporting films to adsorb macromolecules, and when functionalized with affinity ligands, to specifically anchor the target particles away from the AWI. Among these supporting films, graphene, together with its derivatives, with negligible background noise and mechanical robustness, has emerged as a new generation of support. These strategies have been proven successful in various cases and enable us a better handling of the problems caused by the AWI in cryo-EM specimen preparation.
Collapse
Affiliation(s)
- Nan Liu
- Ministry of Education Key Laboratory of Protein Sciences, Beijing Advanced Innovation Center for Structural Biology, Beijing Frontier Research Center for Biological Structures, School of Life Sciences, Tsinghua University, Beijing 100084, China
| | - Hong-Wei Wang
- Ministry of Education Key Laboratory of Protein Sciences, Beijing Advanced Innovation Center for Structural Biology, Beijing Frontier Research Center for Biological Structures, School of Life Sciences, Tsinghua University, Beijing 100084, China; Tsinghua-Peking Joint Center for Life Sciences, Tsinghua University, Beijing 100084, China.
| |
Collapse
|
11
|
Esser TK, Böhning J, Fremdling P, Bharat T, Gault J, Rauschenbach S. Cryo-EM samples of gas-phase purified protein assemblies using native electrospray ion-beam deposition. Faraday Discuss 2022; 240:67-80. [PMID: 36065984 PMCID: PMC9641999 DOI: 10.1039/d2fd00065b] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
An increasing number of studies on biomolecular function indirectly combine mass spectrometry (MS) with imaging techniques such as cryo electron microscopy (cryo-EM). This approach allows information on the homogeneity, stoichiometry, shape, and interactions of native protein complexes to be obtained, complementary to high-resolution protein structures. We have recently demonstrated TEM sample preparation via native electrospray ion-beam deposition (ES-IBD) as a direct link between native MS and cryo-EM. This workflow forms a potential new route to the reliable preparation of homogeneous cryo-EM samples and a better understanding of the relation between native solution-phase and native-like gas-phase structures. However, many aspects of the workflow need to be understood and optimized to obtain performance comparable to that of state-of-the-art cryo-EM. Here, we expand on the previous discussion of key factors by probing the effects of substrate type and deposition energy. We present and discuss micrographs from native ES-IBD samples with amorphous carbon, graphene, and graphene oxide, as well as landing energies in the range between 2 and 150 eV per charge.
Collapse
Affiliation(s)
- Tim K. Esser
- Department of Chemistry, University of OxfordOxfordOX1 3TFUK
| | - Jan Böhning
- Sir William Dunn School of Pathology, University of OxfordSouth Parks RoadOxfordOX1 3REUK
| | - Paul Fremdling
- Department of Chemistry, University of OxfordOxfordOX1 3TFUK
| | - Tanmay Bharat
- Sir William Dunn School of Pathology, University of OxfordSouth Parks RoadOxfordOX1 3REUK,Structural Studies Division, MRC Laboratory of Molecular BiologyFrancis Crick AvenueCambridgeCB2 0QHUK
| | - Joseph Gault
- Department of Chemistry, University of OxfordOxfordOX1 3TFUK
| | - Stephan Rauschenbach
- Department of Chemistry, University of OxfordOxfordOX1 3TFUK,Max Planck Institute for Solid State ResearchHeisenbergstrasse 1StuttgartDE-70569Germany
| |
Collapse
|
12
|
Xu Y, Dang S. Recent Technical Advances in Sample Preparation for Single-Particle Cryo-EM. Front Mol Biosci 2022; 9:892459. [PMID: 35813814 PMCID: PMC9263182 DOI: 10.3389/fmolb.2022.892459] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2022] [Accepted: 05/12/2022] [Indexed: 11/25/2022] Open
Abstract
Cryo-sample preparation is a vital step in the process of obtaining high-resolution structures of macromolecules by using the single-particle cryo–electron microscopy (cryo-EM) method; however, cryo-sample preparation is commonly hampered by high uncertainty and low reproducibility. Specifically, the existence of air-water interfaces during the sample vitrification process could cause protein denaturation and aggregation, complex disassembly, adoption of preferred orientations, and other serious problems affecting the protein particles, thereby making it challenging to pursue high-resolution 3D reconstruction. Therefore, sample preparation has emerged as a critical research topic, and several new methods for application at various preparation stages have been proposed to overcome the aforementioned hurdles. Here, we summarize the methods developed for enhancing the quality of cryo-samples at distinct stages of sample preparation, and we offer insights for developing future strategies based on diverse viewpoints. We anticipate that cryo-sample preparation will no longer be a limiting step in the single-particle cryo-EM field as increasing numbers of methods are developed in the near future, which will ultimately benefit the entire research community.
Collapse
Affiliation(s)
- Yixin Xu
- Division of Life Science, The Hong Kong University of Science and Technology, Kowloon, Hong Kong SAR, China
| | - Shangyu Dang
- Division of Life Science, The Hong Kong University of Science and Technology, Kowloon, Hong Kong SAR, China
- Southern Marine Science and Engineering Guangdong Laboratory (Guangzhou), Guangzhou, China
- Center of Systems Biology and Human Health, The Hong Kong University of Science and Technology, Kowloon, Hong Kong SAR, China
- *Correspondence: Shangyu Dang,
| |
Collapse
|
13
|
Han BG, Armstrong M, Fletcher DA, Glaeser RM. Perspective: Biochemical and Physical Constraints Associated With Preparing Thin Specimens for Single-Particle Cryo-EM. Front Mol Biosci 2022; 9:864829. [PMID: 35573724 PMCID: PMC9100935 DOI: 10.3389/fmolb.2022.864829] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2022] [Accepted: 03/25/2022] [Indexed: 11/13/2022] Open
Abstract
While many aspects of single-particle electron cryo-microscopy (cryo-EM) of biological macromolecules have reached a sophisticated level of development, this is not yet the case when it comes to preparing thin samples on specimen grids. As a result, there currently is considerable interest in achieving better control of both the sample thickness and the amount of area that is useful, but this is only one aspect in which improvement is needed. This Perspective addresses the further need to prevent the macromolecular particles from making contact with the air-water interface, something that can result in preferential orientation and even structural disruption of macromolecular particles. This unwanted contact can occur either as the result of free diffusion of particles during the interval between application, thinning and vitrification of the remaining buffer, or-when particles have been immobilized-by the film of buffer becoming too thin prior to vitrification. An opportunity now exists to apply theoretical and practical insights from the fields of thin-film physical chemistry and interfacial science, in an effort to bring cryo-EM sample preparation to a level of sophistication that is comparable to that of current data collection and analysis.
Collapse
Affiliation(s)
- Bong-Gyoon Han
- Lawrence Berkeley National Laboratory, University of California, Berkeley, Berkeley, CA, United States
| | - Max Armstrong
- Lawrence Berkeley National Laboratory, University of California, Berkeley, Berkeley, CA, United States,Department of Bioengineering, University of California, Berkeley, Berkeley, CA, United States
| | - Daniel A. Fletcher
- Department of Bioengineering, University of California, Berkeley, Berkeley, CA, United States,Biological Systems and Engineering Division, Lawrence Berkeley National Laboratory, University of California, Berkeley, Berkeley, CA, United States,Chan Zuckerberg Biohub, San Francisco, CA, United States
| | - Robert M. Glaeser
- Lawrence Berkeley National Laboratory, University of California, Berkeley, Berkeley, CA, United States,*Correspondence: Robert M. Glaeser,
| |
Collapse
|