1
|
Langaa SS, Lauridsen TG, Mose FH, Fynbo CA, Theil J, Bech JN. Estimation of renal perfusion based on measurement of rubidium-82 clearance by PET/CT scanning in healthy subjects. EJNMMI Phys 2021; 8:43. [PMID: 34057645 PMCID: PMC8167076 DOI: 10.1186/s40658-021-00389-0] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2020] [Accepted: 05/12/2021] [Indexed: 11/18/2022] Open
Abstract
Background Changes in renal blood flow (RBF) may play a pathophysiological role in hypertension and kidney disease. However, RBF determination in humans has proven difficult. We aimed to confirm the feasibility of RBF estimation based on positron emission tomography/computed tomography (PET/CT) and rubidium-82 (82Rb) using the abdominal aorta as input function in a 1-tissue compartment model. Methods Eighteen healthy subjects underwent two dynamic 82Rb PET/CT scans in two different fields of view (FOV). FOV-A included the left ventricular blood pool (LVBP), the abdominal aorta (AA) and the majority of the kidneys. FOV-B included AA and the kidneys in their entirety. In FOV-A, an input function was derived from LVBP and from AA, in FOV-B from AA. One-tissue compartmental modelling was performed using tissue time activity curves generated from volumes of interest (VOI) contouring the kidneys, where the renal clearance of 82Rb is represented by the K1 kinetic parameter. Total clearance for both kidneys was calculated by multiplying the K1 values with the volume of VOIs used for analysis. Intra-assay coefficients of variation and inter-observer variation were calculated. Results For both kidneys, K1 values derived from AA did not differ significantly from values obtained from LVBP, neither were significant differences seen between AA in FOV-A and AA in FOV-B, nor between the right and left kidneys. For both kidneys, the intra-assay coefficients of variation were low (~ 5%) for both input functions. The measured K1 of 2.80 ml/min/cm3 translates to a total clearance for both kidneys of 766 ml/min/1.73 m2. Conclusion Measurement of renal perfusion based on PET/CT and 82Rb using AA as input function in a 1-tissue compartment model is feasible in a single FOV. Based on previous studies showing 82Rb to be primarily present in plasma, the measured K1 clearance values are most likely representative of effective renal plasma flow (ERPF) rather than estimated RBF values, but as the accurate calculation of total clearance/flow is very much dependent on the analysed volume, a standardised definition for the employed renal volumes is needed to allow for proper comparison with standard ERPF and RBF reference methods. Supplementary Information The online version contains supplementary material available at 10.1186/s40658-021-00389-0.
Collapse
Affiliation(s)
- Stine Sundgaard Langaa
- Gødstrup HospitalUniversity Clinic in Nephrology and Hypertension, Department of Medical Research, Gødstrup Hospital and Aarhus University, Lægaardvej 12J, 7500, Holstebro, Denmark.
| | - Thomas Guldager Lauridsen
- Gødstrup HospitalUniversity Clinic in Nephrology and Hypertension, Department of Medical Research, Gødstrup Hospital and Aarhus University, Lægaardvej 12J, 7500, Holstebro, Denmark
| | - Frank Holden Mose
- Gødstrup HospitalUniversity Clinic in Nephrology and Hypertension, Department of Medical Research, Gødstrup Hospital and Aarhus University, Lægaardvej 12J, 7500, Holstebro, Denmark
| | | | - Jørn Theil
- Department of Nuclear Medicine, Gødstrup Hospital, Herning, Denmark.,Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Jesper Nørgaard Bech
- Gødstrup HospitalUniversity Clinic in Nephrology and Hypertension, Department of Medical Research, Gødstrup Hospital and Aarhus University, Lægaardvej 12J, 7500, Holstebro, Denmark
| |
Collapse
|
2
|
Cho SG, Lee SJ, Na MH, Choi YY, Bom HHS. Comparison of diagnostic accuracy of PET-derived myocardial blood flow parameters: A meta-analysis. J Nucl Cardiol 2020; 27:1955-1966. [PMID: 30390243 DOI: 10.1007/s12350-018-01476-z] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2018] [Accepted: 09/24/2018] [Indexed: 11/25/2022]
Abstract
BACKGROUND Although absolute quantification of myocardial blood flow (MBF) by positron emission tomography provides additive diagnostic value to visual analysis of perfusion defect, diagnostic accuracy of different MBF parameters remain unclear. METHODS Clinical studies regarding the diagnostic accuracy of hyperemic MBF (hMBF), myocardial flow reserve (MFR) and/or relative flow reserve (RFR) were searched and systematically reviewed. On a per-vessel basis, pooled measures of the parameters' diagnostic performances were analyzed, regarding significant coronary stenosis defined by fractional flow reserve or diameter stenosis. RESULTS Ten studies (2,522 arteries from 1,099 patients) were finally included. Pooled sensitivity [95% confidence interval (CI)] was 0.853 (0.821-0.881) for hMBF, 0.755 (0.713-0.794) for MFR, and 0.636 (0.539-0.726) for RFR. Pooled specificity (95% CI) was 0.844 (0.827-0.860) for hMBF, 0.804 (0.784-0.824) for MFR, and 0.897 (0.860-0.926) for RFR. Pooled area under the curve ± standard error was 0.900 ± 0.020 for hMBF, 0.830 ± 0.026 for MFR, and 0.873 ± 0.048 for RFR. CONCLUSIONS hMBF showed the best sensitivity while RFR showed the best specificity in the diagnosis of significant coronary stenosis. MFR was less sensitive than hMBF and less specific than hMBF and RFR.
Collapse
Affiliation(s)
- Sang-Geon Cho
- Department of Nuclear Medicine, Chonnam National University Hospital, 42, Jebong-ro, Dong-gu, Gwangju, 61469, Republic of Korea.
| | - Soo Jin Lee
- Department of Nuclear Medicine, Hanyang University Medical Center, 222-1, Wangsimni-ro Seongdong-gu, Seoul, 04763, Republic of Korea
| | - Myung Hwan Na
- Department of Statistics, Chonnam National University, 45, Yongbong-ro, Buk-gu, Kwangju, 61186, Republic of Korea
| | - Yun Young Choi
- Department of Nuclear Medicine, Hanyang University Medical Center, 222-1, Wangsimni-ro Seongdong-gu, Seoul, 04763, Republic of Korea.
| | - Henry Hee-Seung Bom
- Department of Nuclear Medicine, Chonnam National University Hwasun Hospital, 322, Seoyang-ro Hwasun-eup, Hwasun-gun, Jeonnam, 58128, Republic of Korea.
| |
Collapse
|
3
|
EANM procedural guidelines for PET/CT quantitative myocardial perfusion imaging. Eur J Nucl Med Mol Imaging 2020; 48:1040-1069. [PMID: 33135093 PMCID: PMC7603916 DOI: 10.1007/s00259-020-05046-9] [Citation(s) in RCA: 74] [Impact Index Per Article: 18.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2020] [Accepted: 09/17/2020] [Indexed: 12/19/2022]
Abstract
The use of cardiac PET, and in particular of quantitative myocardial perfusion PET, has been growing during the last years, because scanners are becoming widely available and because several studies have convincingly demonstrated the advantages of this imaging approach. Therefore, there is a need of determining the procedural modalities for performing high-quality studies and obtaining from this demanding technique the most in terms of both measurement reliability and clinical data. Although the field is rapidly evolving, with progresses in hardware and software, and the near perspective of new tracers, the EANM Cardiovascular Committee found it reasonable and useful to expose in an updated text the state of the art of quantitative myocardial perfusion PET, in order to establish an effective use of this modality and to help implementing it on a wider basis. Together with the many steps necessary for the correct execution of quantitative measurements, the importance of a multiparametric approach and of a comprehensive and clinically useful report have been stressed.
Collapse
|
4
|
Juttukonda MR, Donahue MJ. Neuroimaging of vascular reserve in patients with cerebrovascular diseases. Neuroimage 2019; 187:192-208. [PMID: 29031532 PMCID: PMC5897191 DOI: 10.1016/j.neuroimage.2017.10.015] [Citation(s) in RCA: 41] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2017] [Revised: 10/01/2017] [Accepted: 10/07/2017] [Indexed: 12/21/2022] Open
Abstract
Cerebrovascular reactivity, defined broadly as the ability of brain parenchyma to adjust cerebral blood flow in response to altered metabolic demand or a vasoactive stimulus, is being measured with increasing frequency and may have a use for portending new or recurrent stroke risk in patients with cerebrovascular disease. The purpose of this review is to outline (i) the physiological basis of variations in cerebrovascular reactivity, (ii) available approaches for measuring cerebrovascular reactivity in research and clinical settings, and (iii) clinically-relevant cerebrovascular reactivity findings in the context of patients with cerebrovascular disease, including atherosclerotic arterial steno-occlusion, non-atherosclerotic arterial steno-occlusion, anemia, and aging. Literature references summarizing safety considerations for these procedures and future directions for standardizing protocols and post-processing procedures across centers are presented in the specific context of major unmet needs in the setting of cerebrovascular disease.
Collapse
Affiliation(s)
- Meher R Juttukonda
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Manus J Donahue
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN, USA; Department of Neurology, Vanderbilt University Medical Center, Nashville, TN, USA; Department of Psychiatry, Vanderbilt University Medical Center, Nashville, TN, USA; Department of Physics and Astronomy, Vanderbilt University, Nashville, TN, USA.
| |
Collapse
|
5
|
Bendriem B, Reed J, McCullough K, Khan MR, Smith AM, Thomas D, Long M. The continual innovation of commercial PET/CT solutions in nuclear cardiology: Siemens Healthineers. J Nucl Cardiol 2018; 25:1400-1411. [PMID: 29637525 PMCID: PMC6133132 DOI: 10.1007/s12350-018-1262-3] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2018] [Accepted: 03/14/2018] [Indexed: 11/30/2022]
Abstract
Cardiac PET/CT is an evolving, non-invasive imaging modality that impacts patient management in many clinical scenarios. Beyond offering the capability to assess myocardial perfusion, inflammatory cardiac pathologies, and myocardial viability, cardiac PET/CT also allows for the non-invasive quantitative assessment of myocardial blood flow (MBF) and myocardial flow reserve (MFR). Recognizing the need for an enhanced comprehension of coronary physiology, Siemens Healthineers implemented a sophisticated solution for the calculation of MBF and MFR in 2009. As a result, each aspect of their innovative scanner and image-processing technology seamlessly integrates into an efficient, easy-to-use workflow for everyday clinical use that maximizes the number of patients who potentially benefit from this imaging modality.
Collapse
Affiliation(s)
| | - Jessie Reed
- Siemens Healthcare GmbH, MI, Knoxville, TN, USA
| | | | | | | | | | - Misty Long
- Siemens Healthcare GmbH, MI, Knoxville, TN, USA
| |
Collapse
|
6
|
Davidson CQ, Phenix CP, Tai TC, Khaper N, Lees SJ. Searching for novel PET radiotracers: imaging cardiac perfusion, metabolism and inflammation. AMERICAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING 2018; 8:200-227. [PMID: 30042871 PMCID: PMC6056242] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 04/03/2018] [Accepted: 05/20/2018] [Indexed: 06/08/2023]
Abstract
Advances in medical imaging technology have led to an increased demand for radiopharmaceuticals for early and accurate diagnosis of cardiac function and diseased states. Myocardial perfusion, metabolism, and hypoxia positron emission tomography (PET) imaging radiotracers for detection of cardiac disease lack specificity for targeting inflammation that can be an early indicator of cardiac disease. Inflammation can occur at all stages of cardiac disease and currently, 18F-fluorodeoxyglucose (FDG), a glucose analog, is the standard for detecting myocardial inflammation. 18F-FDG has many ideal characteristics of a radiotracer but lacks the ability to differentiate between glucose uptake in normal cardiomyocytes and inflammatory cells. Developing a PET radiotracer that differentiates not only between inflammatory cells and normal cardiomyocytes, but between types of immune cells involved in inflammation would be ideal. This article reviews current PET radiotracers used in cardiac imaging, their limitations, and potential radiotracer candidates for imaging cardiac inflammation in early stages of development of acute and chronic cardiac diseases. The select radiotracers reviewed have been tested in animals and/or show potential to be developed as a radiotracer for the detection of cardiac inflammation by targeting the enzymatic activities or subpopulations of macrophages that are recruited to an injured or infected site.
Collapse
Affiliation(s)
| | - Christopher P Phenix
- Department of Chemistry, University of SaskatchewanSaskatoon, Saskatchewan, Canada
| | - TC Tai
- Medical Sciences Division, Northern Ontario School of Medicine, Laurentian UniversitySudbury, Ontario, Canada
| | - Neelam Khaper
- Department of Biology, Lakehead UniversityThunder Bay, Ontario, Canada
- Medical Sciences Division, Northern Ontario School of Medicine, Lakehead UniversityThunder Bay, Ontario, Canada
| | - Simon J Lees
- Department of Biology, Lakehead UniversityThunder Bay, Ontario, Canada
- Medical Sciences Division, Northern Ontario School of Medicine, Lakehead UniversityThunder Bay, Ontario, Canada
| |
Collapse
|
7
|
Assessment of myocardial blood flow and coronary flow reserve with positron emission tomography in ischemic heart disease: current state and future directions. Heart Fail Rev 2018; 22:441-453. [PMID: 28593557 DOI: 10.1007/s10741-017-9625-4] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Positron emission tomography (PET) is a versatile imaging technology that allows assessment of myocardial perfusion, both at a spatially relative scale and also in absolute terms, thereby enabling noninvasive evaluation of myocardial blood flow (MBF) and coronary flow reserve (CFR). Assessment of MBF using FDA-approved PET isotopes, such as 82Rb and 13N-ammonia, has been well validated, and several software packages are currently available, thereby allowing for MBF evaluation to be incorporated into routine workflow in contemporary nuclear laboratories. Incremental diagnostic and prognostic information provided with the knowledge of MBF has the potential for widespread applications. Improving the ability to identify the true burden of obstructive epicardial coronary stenoses and allowing for noninvasive assessment of coronary micro circulatory function can be achieved with MBF assessment. On the other hand, attenuated CFR has been shown to predict adverse cardiovascular prognosis in a variety of clinical settings and patient subgroups. With expanding applications of MBF, this tool promises to provide unique insight into the integrity of the entire coronary vascular bed beyond what is currently available with relative perfusion assessment. This review intends to provide an in-depth discussion of technical and clinical aspects of MBF assessment with PET as it relates to patients with ischemic heart disease.
Collapse
|
8
|
Olivas Arroyo C. Radiopharmaceuticals in positron emission tomography: present situation and future perspectives. RADIOLOGIA 2016; 58:468-480. [PMID: 27592111 DOI: 10.1016/j.rx.2016.07.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2015] [Revised: 05/08/2016] [Accepted: 07/05/2016] [Indexed: 11/29/2022]
Abstract
Positron emission tomography (PET) is an imaging technique that has grown greatly in recent years. PET is considered a fundamental tool in oncology, and it also has indications in other fields such as neurology and cardiology. Although 18F-fluorodeoxyglucose (18F-FDG) is the radiopharmaceutical most widely used in PET, the availability of new radiotracers has been a key element in the expansion of the use of PET. These new radiopharmaceuticals have made it possible to study different biological targets that are essential for obtaining greater knowledge and better characterization of different diseases and have thus contributed to the research and development of different therapeutic agents. This article provides a description of different PET radiopharmaceutical, structured according to their areas of application. Some of these radiotracers are already commercially available, whereas others are still under research or pending approval by regulatory bodies.
Collapse
Affiliation(s)
- C Olivas Arroyo
- Unidad de Radiofarmacia, Servicio de Medicina Nuclear, Hospital Universitari i Politècnic La Fe, Valencia, España.
| |
Collapse
|
9
|
Risk Stratification with Cardiac Rubidium-82 Positron Emission Tomography. CURRENT CARDIOVASCULAR IMAGING REPORTS 2014. [DOI: 10.1007/s12410-014-9266-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
10
|
Chen J. The frontiers of nuclear cardiology research. J Biomed Res 2013; 27:437-8. [PMID: 24285941 PMCID: PMC3841468 DOI: 10.7555/jbr.27.20130150] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2013] [Accepted: 09/20/2013] [Indexed: 11/12/2022] Open
Affiliation(s)
- Ji Chen
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA 30322, USA
| |
Collapse
|