1
|
刘 捷, 闫 炼, 秦 明, 张 海, 陈 明. [Magnetic induced phase shift detection system based on a novel sensor for cerebral hemorrhage]. SHENG WU YI XUE GONG CHENG XUE ZA ZHI = JOURNAL OF BIOMEDICAL ENGINEERING = SHENGWU YIXUE GONGCHENGXUE ZAZHI 2024; 41:455-460. [PMID: 38932530 PMCID: PMC11208648 DOI: 10.7507/1001-5515.202305048] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 05/25/2023] [Revised: 05/13/2024] [Indexed: 06/28/2024]
Abstract
The main magnetic field, generated by the excitation coil of the magnetic induction phase shift technology detection system, is mostly dispersed field with small field strength, and the offset effect needs to be further improved, which makes the detection signal weak and the detection system difficult to achieve quantitative detection, thus the technology is rarely used in vivo experiments and clinical trials. In order to improve problems mentioned above, a new Helmholtz birdcage sensor was designed. Stimulation experiment was carried out to analyze the main magnetic field in aspects of intensity and magnetic distribution, then different bleeding volume and bleeding rates experiments were conducted to compared with traditional sensors. The results showed that magnetic field intensity in detection region was 2.5 times than that of traditional sensors, cancellation effect of the main magnetic field was achieved, the mean value of phase difference of 10 mL rabbit blood was (-3.34 ± 0.21)°, and exponential fitting adjusted R 2 between phase difference and bleeding volumes and bleeding rates were both 0.99. The proposed Helmholtz birdcage sensor has a uniform magnetic field with a higher field strength, enable more accurate quantification of hemorrhage and monitored change of bleeding rates, providing significance in magnetic induced technology research for cerebral hemorrhage detection.
Collapse
Affiliation(s)
- 捷 刘
- 陆军军医大学 生物医学工程与影像医学系(重庆 400038)Department of Biomedical Engineering and Imaging Medicine, Army Medical University, Chongqing 400038, P. R. China
| | - 炼 闫
- 陆军军医大学 生物医学工程与影像医学系(重庆 400038)Department of Biomedical Engineering and Imaging Medicine, Army Medical University, Chongqing 400038, P. R. China
| | - 明新 秦
- 陆军军医大学 生物医学工程与影像医学系(重庆 400038)Department of Biomedical Engineering and Imaging Medicine, Army Medical University, Chongqing 400038, P. R. China
| | - 海生 张
- 陆军军医大学 生物医学工程与影像医学系(重庆 400038)Department of Biomedical Engineering and Imaging Medicine, Army Medical University, Chongqing 400038, P. R. China
| | - 明生 陈
- 陆军军医大学 生物医学工程与影像医学系(重庆 400038)Department of Biomedical Engineering and Imaging Medicine, Army Medical University, Chongqing 400038, P. R. China
| |
Collapse
|
2
|
Lin R, Lei M, Ding S, Cheng Q, Ma Z, Wang L, Tang Z, Zhou B, Zhou Y. Applications of flexible electronics related to cardiocerebral vascular system. Mater Today Bio 2023; 23:100787. [PMID: 37766895 PMCID: PMC10519834 DOI: 10.1016/j.mtbio.2023.100787] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2023] [Revised: 08/14/2023] [Accepted: 08/28/2023] [Indexed: 09/29/2023] Open
Abstract
Ensuring accessible and high-quality healthcare worldwide requires field-deployable and affordable clinical diagnostic tools with high performance. In recent years, flexible electronics with wearable and implantable capabilities have garnered significant attention from researchers, which functioned as vital clinical diagnostic-assisted tools by real-time signal transmission from interested targets in vivo. As the most crucial and complex system of human body, cardiocerebral vascular system together with heart-brain network attracts researchers inputting profuse and indefatigable efforts on proper flexible electronics design and materials selection, trying to overcome the impassable gulf between vivid organisms and rigid inorganic units. This article reviews recent breakthroughs in flexible electronics specifically applied to cardiocerebral vascular system and heart-brain network. Relevant sensor types and working principles, electronics materials selection and treatment methods are expounded. Applications of flexible electronics related to these interested organs and systems are specially highlighted. Through precedent great working studies, we conclude their merits and point out some limitations in this emerging field, thus will help to pave the way for revolutionary flexible electronics and diagnosis assisted tools development.
Collapse
Affiliation(s)
- Runxing Lin
- Joint Key Laboratory of the Ministry of Education, Institute of Applied Physics and Materials Engineering, University of Macau, Avenida da Universidade, Taipa, Macau, 999078, China
- Brain Cognition and Brain Disease Institute, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, China
| | - Ming Lei
- Joint Key Laboratory of the Ministry of Education, Institute of Applied Physics and Materials Engineering, University of Macau, Avenida da Universidade, Taipa, Macau, 999078, China
| | - Sen Ding
- Joint Key Laboratory of the Ministry of Education, Institute of Applied Physics and Materials Engineering, University of Macau, Avenida da Universidade, Taipa, Macau, 999078, China
| | - Quansheng Cheng
- Joint Key Laboratory of the Ministry of Education, Institute of Applied Physics and Materials Engineering, University of Macau, Avenida da Universidade, Taipa, Macau, 999078, China
| | - Zhichao Ma
- Institute of Medical Robotics, School of Biomedical Engineering, Shanghai Jiao Tong University, No.800 Dongchuan Road, Shanghai, 200240, China
| | - Liping Wang
- Brain Cognition and Brain Disease Institute, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, China
| | - Zikang Tang
- Joint Key Laboratory of the Ministry of Education, Institute of Applied Physics and Materials Engineering, University of Macau, Avenida da Universidade, Taipa, Macau, 999078, China
| | - Bingpu Zhou
- Joint Key Laboratory of the Ministry of Education, Institute of Applied Physics and Materials Engineering, University of Macau, Avenida da Universidade, Taipa, Macau, 999078, China
| | - Yinning Zhou
- Joint Key Laboratory of the Ministry of Education, Institute of Applied Physics and Materials Engineering, University of Macau, Avenida da Universidade, Taipa, Macau, 999078, China
- Department of Physics and Chemistry, Faculty of Science and Technology, University of Macau, Avenida da Universidade, Taipa, Macau, 999078, China
| |
Collapse
|
3
|
Li M, Zhu R, Li G, Yin S, Zeng L, Bai Z, Chen J, Jiang B, Li L, Wu Y. Point-of-care testing for cerebral edema types based on symmetric cancellation near-field coupling phase shift and support vector machine. Biomed Eng Online 2023; 22:80. [PMID: 37582824 PMCID: PMC10428563 DOI: 10.1186/s12938-023-01145-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2022] [Accepted: 08/07/2023] [Indexed: 08/17/2023] Open
Abstract
BACKGROUND Cerebral edema is an extremely common secondary disease in post-stroke. Point-of-care testing for cerebral edema types has important clinical significance for the precise management to prevent poor prognosis. Nevertheless, there has not been a fully accepted bedside testing method for that. METHODS A symmetric cancellation near-field coupling phase shift (NFCPS) monitoring system is established based on the symmetry of the left and right hemispheres and the fact that unilateral lesions do not affect healthy hemispheres. For exploring the feasibility of this system to reflect the occurrence and development of cerebral edema, 13 rabbits divided into experimental group (n = 8) and control group (n = 5) were performed 24-h NFCPS continuous monitoring experiments. After time difference offset and feature band averaging processing, the changing trend of NFCPS at the stages dominated by cytotoxic edema (CE) and vasogenic edema (VE), respectively, was analyzed. Furthermore, the features under the different time windows were extracted. Then, a discriminative model of cerebral edema types based on support vector machines (SVM) was established and performance of multiple feature combinations was compared. RESULTS The NFCPS monitoring outcomes of experimental group endured focal ischemia modeling by thrombin injection show a trend of first decreasing and then increasing, reaching the lowest value of - 35.05° at the 6th hour. Those of control group do not display obvious upward or downward trend and only fluctuate around the initial value with an average change of - 0.12°. Furthermore, four features under the 1-h and 2-h time windows were extracted. Based on the discriminative model of cerebral edema types, the classification accuracy of 1-h window is higher than 90% and the specificity is close to 1, which is almost the same as the performance of the 2-h window. CONCLUSION This study proves the feasibility of NFCPS technology combined with SVM to distinguish cerebral edema types in a short time, which is promised to become a new solution for immediate and precise management of dehydration therapy after ischemic stroke.
Collapse
Affiliation(s)
- Mingyan Li
- School of Pharmacy and Bioengineering, Chongqing University of Technology, Chongqing, 400054 China
- College of Artificial Intelligence, Chongqing University of Technology, Chongqing, 401135 China
| | - Rui Zhu
- School of Pharmacy and Bioengineering, Chongqing University of Technology, Chongqing, 400054 China
| | - Gen Li
- School of Pharmacy and Bioengineering, Chongqing University of Technology, Chongqing, 400054 China
- Department of Neurosurgery, Southwest Hospital, Army Medical University, Chongqing, 400038 China
| | - Shengtong Yin
- School of Pharmacy and Bioengineering, Chongqing University of Technology, Chongqing, 400054 China
| | - Lingxi Zeng
- School of Pharmacy and Bioengineering, Chongqing University of Technology, Chongqing, 400054 China
| | - Zelin Bai
- College of Biomedical Engineering, Army Medical University, Chongqing, 400038 China
| | - Jingbo Chen
- College of Biomedical Engineering, Army Medical University, Chongqing, 400038 China
| | - Bin Jiang
- College of Artificial Intelligence, Chongqing University of Technology, Chongqing, 401135 China
| | - Lihong Li
- College of Artificial Intelligence, Chongqing University of Technology, Chongqing, 401135 China
| | - Yu Wu
- School of Pharmacy and Bioengineering, Chongqing University of Technology, Chongqing, 400054 China
| |
Collapse
|
4
|
Li G, Yin S, Jian M, Chen J, Zeng L, Bai Z, Zhuang W, Xu B, He S, Sun J, Chen Y. Early assessment of acute ischemic stroke in rabbits based on multi-parameter near-field coupling sensing. Biomed Eng Online 2022; 21:20. [PMID: 35346206 PMCID: PMC8962490 DOI: 10.1186/s12938-022-00991-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2021] [Accepted: 03/17/2022] [Indexed: 11/25/2022] Open
Abstract
Background Early diagnosis and continuous monitoring are the key to emergency treatment and intensive care of patients with acute ischemic stroke (AIS). Nevertheless, there has not been a fully accepted method targeting continuous assessment of AIS in clinical. Methods Near-field coupling (NFC) sensing can obtain the conductivity related to the volume of intracranial components with advantages of non-invasiveness, strong penetrability and real-time monitoring. In this work, we built a multi-parameter monitoring system that is able to measure changes of phase and amplitude in the process of electromagnetic wave (EW) reflection and transmission. For investigating its feasibility in AIS detection, 16 rabbits were chosen to establish AIS models by bilateral common carotid artery ligation and then were enrolled for monitoring experiments. Results During the 6 h after AIS, the reflection amplitude (RA) shows a decline trend with a range of 0.69 dB and reflection phase (RP) has an increased variation of 6.48° . Meanwhile, transmission amplitude (TA) and transmission phase (TP) decrease 2.14 dB and 24.29° , respectively. The statistical analysis illustrates that before ligation, 3 h after ligation and 6 h after ligation can be effectively distinguished by the four parameters individually. When all those parameters are regarded as recognition features in back propagation (BP) network, the classification accuracy of the three different periods reaches almost 100%. Conclusion These results prove the feasibility of multi-parameter NFC sensing to assess AIS, which is promised to become an outstanding point-of-care testing method in the future.
Collapse
|
5
|
Chen J, Li G, Liang H, Zhao S, Sun J, Qin M. An amplitude-based characteristic parameter extraction algorithm for cerebral edema detection based on electromagnetic induction. Biomed Eng Online 2021; 20:74. [PMID: 34344370 PMCID: PMC8335876 DOI: 10.1186/s12938-021-00913-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2021] [Accepted: 07/26/2021] [Indexed: 11/10/2022] Open
Abstract
Background Cerebral edema is a common condition secondary to any type of neurological injury. The early diagnosis and monitoring of cerebral edema is of great importance to improve the prognosis. In this article, a flexible conformal electromagnetic two-coil sensor was employed as the electromagnetic induction sensor, associated with a vector network analyzer (VNA) for signal generation and receiving. Measurement of amplitude data over the frequency range of 1–100 MHz is conducted to evaluate the changes in cerebral edema. We proposed an Amplitude-based Characteristic Parameter Extraction (Ab-CPE) algorithm for multi-frequency characteristic analysis over the frequency range of 1–100 MHz and investigated its performance in electromagnetic induction-based cerebral edema detection and distinction of its acute/chronic phase. Fourteen rabbits were enrolled to establish cerebral edema model and the 24 h real-time monitoring experiments were carried out for algorithm verification. Results The proposed Ab-CPE algorithm was able to detect cerebral edema with a sensitivity of 94.1% and specificity of 95.4%. Also, in the early stage, it can detect cerebral edema with a sensitivity of 85.0% and specificity of 87.5%. Moreover, the Ab-CPE algorithm was able to distinguish between acute and chronic phase of cerebral edema with a sensitivity of 85.0% and specificity of 91.0%. Conclusion The proposed Ab-CPE algorithm is suitable for multi-frequency characteristic analysis. Combined with this algorithm, the electromagnetic induction method has an excellent performance on the detection and monitoring of cerebral edema.
Collapse
Affiliation(s)
- Jingbo Chen
- College of Biomedical Engineering, Third Military Medical University (Army Medical University), Chongqing, China
| | - Gen Li
- School of Pharmacy and Bioengineering, Chongqing University of Technology, Chongqing, China.
| | - Huayou Liang
- China Aerodynamics Research and Development Center Low Speed Aerodynamic Institute, Mianyang, Sichuan, China
| | - Shuanglin Zhao
- College of Biomedical Engineering, Third Military Medical University (Army Medical University), Chongqing, China
| | - Jian Sun
- College of Biomedical Engineering, Third Military Medical University (Army Medical University), Chongqing, China
| | - Mingxin Qin
- College of Biomedical Engineering, Third Military Medical University (Army Medical University), Chongqing, China.
| |
Collapse
|