1
|
Yu Z, Sun X, Bai X, Ding W, Wang W, Xu L, Qin W, Wen L, Jin Y. Perioperative and Postoperative Complications of Supraclavicular, Ultrasound-Guided, Totally Implantable Venous Access Port via the Brachiocephalic Vein in Adult Patients: A Retrospective Multicentre Study. Ther Clin Risk Manag 2021; 17:137-144. [PMID: 33568912 PMCID: PMC7869700 DOI: 10.2147/tcrm.s292230] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2020] [Accepted: 01/20/2021] [Indexed: 12/25/2022] Open
Abstract
PURPOSE The totally implantable venous access port (TIVAP) provides patients with safe, effective and long-term convenient venous access for the administration of medications such as chemotherapy drugs. The implantation and long-term use of TIVAP are related to thrombosis, infection and other complications. In this study, the medical records of multicentre patients were collected, and the perioperative and postoperative complications were retrospectively analysed to objectively evaluate the safety of the implantation of supraclavicular, ultrasound-guided TIVAP via the brachiocephalic vein (BCV). PATIENTS AND METHODS We retrospectively analysed the clinical data of 433 adult patients who had undergone ultrasound-guided TIVAP implantation via the BCV at four hospitals in China from March 2018 to May 2019. The success rates of the first puncture, operation time, and perioperative and postoperative complications were analysed. RESULTS All the TIVAPs were implanted successfully (100%). The average TIVAP carrying time was 318.15 ±44.22 days (range: 38-502 days) for a total of 197,694 catheter days. The success rate of the first puncture was 94.92% (411/433), and the average operation time was 29.66 ±7.45 min (range: 18-60 min). The perioperative complications included arterial puncture in 4 patients and pneumothorax in 1 patient. The incidence of postoperative complications was 5.08% (22/433), including poor incision healing (n = 2), catheter-related infection (n = 3), port infection (n = 6), thrombosis (n = 2) and fibrin sheath formation (n = 8). Another patient had infusion disturbance 2 days after the operation, and chest X-ray showed bending at the connection between the catheter and port. No other serious complications occurred, such as catheter rupture and drug leakage. The total incidence of complications was 6.24% (27/433). CONCLUSION This study showed excellent tolerance of supraclavicular, ultrasound-guided BCV puncture to implant TIVAP and a low incidence of complications. As a safe and effective method of TIVAP implantation, it can provide a new choice for clinicians.
Collapse
Affiliation(s)
- Zepeng Yu
- Department of Intervention, The Second Affiliated Hospital of Soochow University, Suzhou, 215004, Jiangsu, People’s Republic of China
| | - Xingwei Sun
- Department of Intervention, The Second Affiliated Hospital of Soochow University, Suzhou, 215004, Jiangsu, People’s Republic of China
| | - Xuming Bai
- Department of Intervention, The Second Affiliated Hospital of Soochow University, Suzhou, 215004, Jiangsu, People’s Republic of China
| | - Wei Ding
- Department of Intervention, Wuxi People’s Hospital Affiliated to Nanjing Medical University, Wuxi, 214023, Jiangsu Province, People’s Republic of China
| | - WeiDong Wang
- Department of Intervention, Wuxi People’s Hospital Affiliated to Nanjing Medical University, Wuxi, 214023, Jiangsu Province, People’s Republic of China
| | - Liang Xu
- Department of General Surgery, Changshu Hospital Affiliated to Nanjing University of Chinese Medicine, Changshu, 215500, Jiangsu, People’s Republic of China
| | - Wenming Qin
- Department of Anesthesiology, Bazhong Central Hospital, Bazhong, Sichuan, 636000, People’s Republic of China
| | - Ling Wen
- Department of Radiology, The First Affiliated Hospital of Soochow University, Suzhou, 215004, Jiangsu, People’s Republic of China
| | - Yong Jin
- Department of Intervention, The Second Affiliated Hospital of Soochow University, Suzhou, 215004, Jiangsu, People’s Republic of China
| |
Collapse
|
2
|
Sun X, Bai X, Shen J, Yu Z, Zhuang Z, Jin Y. Comparison between ultrasound-guided TIVAD via the right innominate vein and the right internal jugular vein approach. BMC Surg 2019; 19:189. [PMID: 31829196 PMCID: PMC6907195 DOI: 10.1186/s12893-019-0651-0] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2019] [Accepted: 11/21/2019] [Indexed: 12/11/2022] Open
Abstract
BACKGROUND To compare the efficacy and safety of right internal jugular vein (IJV) approach and right innominate vein (INV) approach for US-guided totally implantable venous access devices (TIVADs), and to explore the advantages and disadvantages of the two approaches. METHODS Six hundred and nineteen adult patients had long-term infusion and chemotherapy needs and inconvenience of peripheral venous infusion. Right INV approach was used to implant 339 cases of TIVADs, and right IJV approach was used to implant 280 cases of TIVADs. The success rate of one-time catheterization and the incidence of complications in the two groups were retrospectively analyzed. RESULTS All patients were successfully implanted in TIVAD. The success rates of one-time puncture in INV group and IJV approach group were 98.53% (334/339) and 95.36% (267/280), respectively. There was significant difference between the two groups (P = 0.020). The incidence of perioperative complications and long-term complications in the right INV group were 1.18% (4/339) and 3.54% (12/339), respectively, while those in the right IJV group were 1.43% (4280) and 3.93% (11280). There was no significant difference in the incidence of perioperative or long-term complications between the two groups (P = 0.785, P = 0.799, respectively). CONCLUSIONS US-guided TIVADs via the right INV approach and the right IJV approach are both safe and reliable. The right INV approach improves the one-time puncture success rate, as long as the technique is properly operated, serious complications rarely occur.
Collapse
Affiliation(s)
- Xingwei Sun
- Department of Intervention, The Second Affiliated Hospital of Soochow University, Suzhou, 215004 Jiangsu China
| | - Xuming Bai
- Department of Intervention, The Second Affiliated Hospital of Soochow University, Suzhou, 215004 Jiangsu China
| | - Jiaofeng Shen
- Department of Oncology, The Second Affiliated Hospital of Soochow University, Suzhou, 215004 Jiangsu China
| | - Ziyang Yu
- Department of Ultrasound, The Second Affiliated Hospital of Soochow University, Suzhou, 215004 Jiangsu China
| | - Zhixiang Zhuang
- Department of Oncology, The Second Affiliated Hospital of Soochow University, Suzhou, 215004 Jiangsu China
| | - Yong Jin
- Department of Intervention, The Second Affiliated Hospital of Soochow University, Suzhou, 215004 Jiangsu China
| |
Collapse
|