Guo F, Zhou W, Luo Z. Numerical simulation of neural excitation during brain tumor ablation by microsecond pulses. Bioelectrochemistry 2024; 160:108752. [PMID: 38852384 DOI: 10.1016/j.bioelechem.2024.108752] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2024] [Revised: 05/09/2024] [Accepted: 05/29/2024] [Indexed: 06/11/2024]
Abstract
Replacing monopolar pulse with bipolar pulses of the same energized time can minimize unnecessary neurological side effects during irreversible electroporation (IRE). An improved neural excitation model that considers dynamic conductivity and thermal effects during brain tumor IRE ablation was proposed for the first time in this study. Nerve fiber excitation during IRE ablation by applying a monopolar pulse (100 μs) and a burst of bipolar pulses (energized time of 100 μs with both the sub-pulse length and interphase delay of 1 μs) was investigated. Our results suggest that both thermal effects and dynamic conductivity change the onset time of action potential (AP), and dynamic conductivity also changes the hyperpolarization amplitude. Considering both thermal effects and dynamic conductivity, the hyperpolarization amplitude in nerve fibers located 2 cm from the tumor center was reduced by approximately 23.8 mV and the onset time of AP was delayed by approximately 17.5 μs when a 500 V monopolar pulse was applied. Moreover, bipolar pulses decreased the excitable volume of brain tissue by approximately 68.8 % compared to monopolar pulse. Finally, bipolar pulses cause local excitation with lesser damage to surrounding healthy tissue in complete tumor ablation, demonstrating the potential benefits of bipolar pulses in brain tissue ablation.
Collapse
Affiliation(s)
- Fei Guo
- Institute of Ecological Safety, Chongqing University of Posts and Telecommunications, Chongqing 400065, China.
| | - Weina Zhou
- Institute of Ecological Safety, Chongqing University of Posts and Telecommunications, Chongqing 400065, China
| | - Zhijun Luo
- Institute of Ecological Safety, Chongqing University of Posts and Telecommunications, Chongqing 400065, China
| |
Collapse
|
2
|
Radzevičiūtė-Valčiukė E, Gečaitė J, Balevičiūtė A, Szewczyk A, Želvys A, Lekešytė B, Malyško-Ptašinskė V, Mickevičiūtė E, Malakauskaitė P, Kulbacka J, Novickij V. Effects of buffer composition and plasmid toxicity on electroporation-based non-viral gene delivery in mammalian cells using bursts of nanosecond and microsecond pulses. Front Bioeng Biotechnol 2024; 12:1430637. [PMID: 39050682 PMCID: PMC11266100 DOI: 10.3389/fbioe.2024.1430637] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2024] [Accepted: 06/17/2024] [Indexed: 07/27/2024] Open
Abstract
Gene electrotransfer (GET) is non-viral gene delivery technique, also known as electroporation-mediated gene delivery or electrotransfection. GET is a method used to introduce foreign genetic material (such as DNA or RNA) into cells by applying external pulsed electric fields (PEFs) to create temporary pores in the cell membrane. This study was undertaken to examine the impact of buffer composition on the efficiency of GET in mammalian cells Also, we specifically compared the effectiveness of high-frequency nanosecond (ns) pulses with standard microsecond (µs) pulses. For the assessment of cell transfection efficiency and viability, flow cytometric analysis, luminescent assays, and measurements of metabolic activity were conducted. The efficiency of electrotransfection was evaluated using two different proteins encoding plasmids (pEGFP-N1 and Luciferase-pcDNA3). The investigation revealed that the composition of the electroporation buffer significantly influences the efficacy of GET in CHO-K1 cell line. The different susceptibility of cell lines to the electric field and the plasmid cytotoxicity were reported. It was also shown that electroporation with nanosecond duration PEF protocols ensured equivalent or even better transfection efficiency than standard µsPEF. Additionally, we successfully performed long-term transfection of the murine 4T1 cell line using high-frequency nanosecond PEFs and confirmed its' applicability in an in vivo model. The findings from the study can be applied to optimize electrotransfection conditions.
Collapse
Affiliation(s)
- Eivina Radzevičiūtė-Valčiukė
- State Research Institute Centre for Innovative Medicine, Department of Immunology and Bioelectrochemistry, Vilnius, Lithuania
- Faculty of Electronics, Vilnius Gediminas Technical University, Vilnius, Lithuania
| | - Jovita Gečaitė
- State Research Institute Centre for Innovative Medicine, Department of Immunology and Bioelectrochemistry, Vilnius, Lithuania
| | - Austėja Balevičiūtė
- State Research Institute Centre for Innovative Medicine, Department of Immunology and Bioelectrochemistry, Vilnius, Lithuania
| | - Anna Szewczyk
- State Research Institute Centre for Innovative Medicine, Department of Immunology and Bioelectrochemistry, Vilnius, Lithuania
- Faculty of Pharmacy, Department of Molecular and Cellular Biology, Wroclaw Medical University, Wroclaw, Poland
| | - Augustinas Želvys
- State Research Institute Centre for Innovative Medicine, Department of Immunology and Bioelectrochemistry, Vilnius, Lithuania
- Faculty of Electronics, Vilnius Gediminas Technical University, Vilnius, Lithuania
| | - Barbora Lekešytė
- State Research Institute Centre for Innovative Medicine, Department of Immunology and Bioelectrochemistry, Vilnius, Lithuania
- Faculty of Electronics, Vilnius Gediminas Technical University, Vilnius, Lithuania
| | | | - Eglė Mickevičiūtė
- State Research Institute Centre for Innovative Medicine, Department of Immunology and Bioelectrochemistry, Vilnius, Lithuania
- Faculty of Electronics, Vilnius Gediminas Technical University, Vilnius, Lithuania
| | - Paulina Malakauskaitė
- State Research Institute Centre for Innovative Medicine, Department of Immunology and Bioelectrochemistry, Vilnius, Lithuania
- Faculty of Electronics, Vilnius Gediminas Technical University, Vilnius, Lithuania
| | - Julita Kulbacka
- State Research Institute Centre for Innovative Medicine, Department of Immunology and Bioelectrochemistry, Vilnius, Lithuania
- Faculty of Pharmacy, Department of Molecular and Cellular Biology, Wroclaw Medical University, Wroclaw, Poland
| | - Vitalij Novickij
- State Research Institute Centre for Innovative Medicine, Department of Immunology and Bioelectrochemistry, Vilnius, Lithuania
- Faculty of Electronics, Vilnius Gediminas Technical University, Vilnius, Lithuania
| |
Collapse
|
3
|
Li M, Liu L, Li X, Li J, Zhao C, Zhao Y, Zhang X, He P, Wu X, Jiang S, Wang X, Zhang X, Wei L. Lipid Nanoparticles Outperform Electroporation in Delivering Therapeutic HPV DNA Vaccines. Vaccines (Basel) 2024; 12:666. [PMID: 38932395 PMCID: PMC11209142 DOI: 10.3390/vaccines12060666] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2024] [Revised: 06/05/2024] [Accepted: 06/12/2024] [Indexed: 06/28/2024] Open
Abstract
Therapeutic HPV vaccines that induce potent HPV-specific cellular immunity and eliminate pre-existing infections remain elusive. Among various candidates under development, those based on DNA constructs are considered promising because of their safety profile, stability, and efficacy. However, the use of electroporation (EP) as a main delivery method for such vaccines is notorious for adverse effects like pain and potentially irreversible muscle damage. Moreover, the requirement for specialized equipment adds to the complexity and cost of clinical applications. As an alternative to EP, lipid nanoparticles (LNPs) that are already commercially available for delivering mRNA and siRNA vaccines are likely to be feasible. Here, we have compared three intramuscular delivery systems in a preclinical setting. In terms of HPV-specific cellular immune responses, mice receiving therapeutic HPV DNA vaccines encapsulated with LNP demonstrated superior outcomes when compared to EP administration, while the naked plasmid vaccine showed negligible responses, as expected. In addition, SM-102 LNP M exhibited the most promising results in delivering candidate DNA vaccines. Thus, LNP proves to be a feasible delivery method in vivo, offering improved immunogenicity over traditional approaches.
Collapse
Affiliation(s)
- Mingzhu Li
- Department of Obstetrics and Gynecology, Peking University People’s Hospital, No. 11 Xizhimen South Street, Beijing 100044, China; (M.L.); (J.L.); (C.Z.); (Y.Z.)
| | - Lei Liu
- Aeonvital Institute of Clinical and Translational Immunology (AICTI), Beijing 102600, China; (L.L.); (X.L.); (X.Z.); (P.H.); (X.W.); (S.J.); (X.W.)
| | - Xiaoli Li
- Aeonvital Institute of Clinical and Translational Immunology (AICTI), Beijing 102600, China; (L.L.); (X.L.); (X.Z.); (P.H.); (X.W.); (S.J.); (X.W.)
| | - Jingran Li
- Department of Obstetrics and Gynecology, Peking University People’s Hospital, No. 11 Xizhimen South Street, Beijing 100044, China; (M.L.); (J.L.); (C.Z.); (Y.Z.)
| | - Chao Zhao
- Department of Obstetrics and Gynecology, Peking University People’s Hospital, No. 11 Xizhimen South Street, Beijing 100044, China; (M.L.); (J.L.); (C.Z.); (Y.Z.)
| | - Yun Zhao
- Department of Obstetrics and Gynecology, Peking University People’s Hospital, No. 11 Xizhimen South Street, Beijing 100044, China; (M.L.); (J.L.); (C.Z.); (Y.Z.)
| | - Xiaopeng Zhang
- Aeonvital Institute of Clinical and Translational Immunology (AICTI), Beijing 102600, China; (L.L.); (X.L.); (X.Z.); (P.H.); (X.W.); (S.J.); (X.W.)
| | - Panpan He
- Aeonvital Institute of Clinical and Translational Immunology (AICTI), Beijing 102600, China; (L.L.); (X.L.); (X.Z.); (P.H.); (X.W.); (S.J.); (X.W.)
| | - Xiaoyu Wu
- Aeonvital Institute of Clinical and Translational Immunology (AICTI), Beijing 102600, China; (L.L.); (X.L.); (X.Z.); (P.H.); (X.W.); (S.J.); (X.W.)
| | - Siwen Jiang
- Aeonvital Institute of Clinical and Translational Immunology (AICTI), Beijing 102600, China; (L.L.); (X.L.); (X.Z.); (P.H.); (X.W.); (S.J.); (X.W.)
| | - Xingxing Wang
- Aeonvital Institute of Clinical and Translational Immunology (AICTI), Beijing 102600, China; (L.L.); (X.L.); (X.Z.); (P.H.); (X.W.); (S.J.); (X.W.)
| | - Xiujun Zhang
- Aeonvital Institute of Clinical and Translational Immunology (AICTI), Beijing 102600, China; (L.L.); (X.L.); (X.Z.); (P.H.); (X.W.); (S.J.); (X.W.)
| | - Lihui Wei
- Department of Obstetrics and Gynecology, Peking University People’s Hospital, No. 11 Xizhimen South Street, Beijing 100044, China; (M.L.); (J.L.); (C.Z.); (Y.Z.)
| |
Collapse
|
4
|
Gabay B, Levkov K, Berl A, Wise J, Shir-Az O, Vitkin E, Saulis G, Shalom A, Golberg A. Electroporation-Based Biopsy Treatment Planning with Numerical Models and Tissue Phantoms. Ann Biomed Eng 2024; 52:71-88. [PMID: 37154990 DOI: 10.1007/s10439-023-03208-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2023] [Accepted: 04/10/2023] [Indexed: 05/10/2023]
Abstract
Molecular sampling with vacuum-assisted tissue electroporation is a novel, minimally invasive method for molecular profiling of solid lesions. In this paper, we report on the design of the battery-powered pulsed electric field generator and electrode configuration for an electroporation-based molecular sampling device for skin cancer diagnostics. Using numerical models of skin electroporation corroborated by the potato tissue phantom model, we show that the electroporated tissue volume, which is the maximum volume for biomarker sampling, strongly depends on the electrode's geometry, needle electrode skin penetration depths, and the applied pulsed electric field protocol. In addition, using excised human basal cell carcinoma (BCC) tissues, we show that diffusion of proteins out of human BCC tissues into water strongly depends on the strength of the applied electric field and on the time after the field application. The developed numerical simulations, confirmed by experiments in potato tissue phantoms and excised human cancer lesions, provide essential tools for the development of electroporation-based molecular markers sampling devices for personalized skin cancer diagnostics.
Collapse
Affiliation(s)
- Batel Gabay
- Porter School of Environment and Earth Sciences, Tel Aviv University, Tel Aviv, Israel
| | - Klimentiy Levkov
- Porter School of Environment and Earth Sciences, Tel Aviv University, Tel Aviv, Israel
| | - Ariel Berl
- Department of Plastic Surgery, Meir Medical Center, Kfar Sava, Israel
| | - Julia Wise
- Porter School of Environment and Earth Sciences, Tel Aviv University, Tel Aviv, Israel
| | - Ofir Shir-Az
- Department of Plastic Surgery, Meir Medical Center, Kfar Sava, Israel
| | - Edward Vitkin
- Porter School of Environment and Earth Sciences, Tel Aviv University, Tel Aviv, Israel
| | - Gintautas Saulis
- Faculty of Natural Sciences, Vytautas Magnus University, Kaunas, Lithuania
| | - Avshalom Shalom
- Department of Plastic Surgery, Meir Medical Center, Kfar Sava, Israel
| | - Alexander Golberg
- Porter School of Environment and Earth Sciences, Tel Aviv University, Tel Aviv, Israel.
| |
Collapse
|
5
|
Vitkin E, Singh A, Wise J, Ben-Elazar S, Yakhini Z, Golberg A. Nondestructive protein sampling with electroporation facilitates profiling of spatial differential protein expression in breast tumors in vivo. Sci Rep 2022; 12:15835. [PMID: 36151122 PMCID: PMC9508265 DOI: 10.1038/s41598-022-19984-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2022] [Accepted: 09/07/2022] [Indexed: 11/26/2022] Open
Abstract
Excision tissue biopsy, while central to cancer treatment and precision medicine, presents risks to the patient and does not provide a sufficiently broad and faithful representation of the heterogeneity of solid tumors. Here we introduce e-biopsy—a novel concept for molecular profiling of solid tumors using molecular sampling with electroporation. As e-biopsy provides access to the molecular composition of a solid tumor by permeabilization of the cell membrane, it facilitates tumor diagnostics without tissue resection. Furthermore, thanks to its non tissue destructive characteristics, e-biopsy enables probing the solid tumor multiple times in several distinct locations in the same procedure, thereby enabling the spatial profiling of tumor molecular heterogeneity.We demonstrate e-biopsy in vivo, using the 4T1 breast cancer model in mice to assess its performance, as well as the inferred spatial differential protein expression. In particular, we show that proteomic profiles obtained via e-biopsy in vivo distinguish the tumors from healthy breast tissue and reflect spatial tumor differential protein expression. E-biopsy provides a completely new molecular sampling modality for solid tumors molecular cartography, providing information that potentially enables more rapid and sensitive detection at lesser risk, as well as more precise personalized medicine.
Collapse
Affiliation(s)
- Edward Vitkin
- School of Computer Science, Reichman University (IDC Herzliya), Herzliya, Israel
| | - Amrita Singh
- Porter School of Environment and Earth Sciences, Tel Aviv University, Tel Aviv, Israel
| | - Julia Wise
- Porter School of Environment and Earth Sciences, Tel Aviv University, Tel Aviv, Israel
| | - Shay Ben-Elazar
- School of Computer Science, Reichman University (IDC Herzliya), Herzliya, Israel
| | - Zohar Yakhini
- School of Computer Science, Reichman University (IDC Herzliya), Herzliya, Israel. .,Computer Science Faculty, Technion, Haifa, Israel.
| | - Alexander Golberg
- Porter School of Environment and Earth Sciences, Tel Aviv University, Tel Aviv, Israel.
| |
Collapse
|
6
|
Genish I, Gabay B, Ruban A, Goldshmit Y, Singh A, Wise J, Levkov K, Shalom A, Vitkin E, Yakhini Z, Golberg A. Electroporation-based proteome sampling ex vivo enables the detection of brain melanoma protein signatures in a location proximate to visible tumor margins. PLoS One 2022; 17:e0265866. [PMID: 35588133 PMCID: PMC9119512 DOI: 10.1371/journal.pone.0265866] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2022] [Accepted: 05/03/2022] [Indexed: 01/09/2023] Open
Abstract
A major concern in tissue biopsies with a needle is missing the most lethal clone of a tumor, leading to a false negative result. This concern is well justified, since needle-based biopsies gather tissue information limited to needle size. In this work, we show that molecular harvesting with electroporation, e-biopsy, could increase the sampled tissue volume in comparison to tissue sampling by a needle alone. Suggested by numerical models of electric fields distribution, the increased sampled volume is achieved by electroporation-driven permeabilization of cellular membranes in the tissue around the sampling needle. We show that proteomic profiles, sampled by e-biopsy from the brain tissue, ex vivo, at 0.5mm distance outside the visible margins of mice brain melanoma metastasis, have protein patterns similar to melanoma tumor center and different from the healthy brain tissue. In addition, we show that e-biopsy probed proteome signature differentiates between melanoma tumor center and healthy brain in mice. This study suggests that e-biopsy could provide a novel tool for a minimally invasive sampling of molecules in tissue in larger volumes than achieved with traditional needle biopsies.
Collapse
Affiliation(s)
- Ilai Genish
- School of Computer Science, Reichman University, Herzliya, Israel
| | - Batel Gabay
- Porter School of Environment and Earth Sciences, Faculty of Exact Sciences, Tel Aviv University, Tel Aviv, Israel
| | - Angela Ruban
- Steyer School of Health Professions, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Yona Goldshmit
- Steyer School of Health Professions, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Amrita Singh
- Porter School of Environment and Earth Sciences, Faculty of Exact Sciences, Tel Aviv University, Tel Aviv, Israel
| | - Julia Wise
- Porter School of Environment and Earth Sciences, Faculty of Exact Sciences, Tel Aviv University, Tel Aviv, Israel
| | - Klimentiy Levkov
- Porter School of Environment and Earth Sciences, Faculty of Exact Sciences, Tel Aviv University, Tel Aviv, Israel
| | - Avshalom Shalom
- Plastic Surgery Department, Meir Medical Center, Kefar Sava, Israel
| | - Edward Vitkin
- School of Computer Science, Reichman University, Herzliya, Israel
| | - Zohar Yakhini
- School of Computer Science, Reichman University, Herzliya, Israel
| | - Alexander Golberg
- Porter School of Environment and Earth Sciences, Faculty of Exact Sciences, Tel Aviv University, Tel Aviv, Israel
| |
Collapse
|
7
|
Muscle contractions and pain sensation accompanying high-frequency electroporation pulses. Sci Rep 2022; 12:8019. [PMID: 35577873 PMCID: PMC9110404 DOI: 10.1038/s41598-022-12112-9] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2021] [Accepted: 05/05/2022] [Indexed: 12/21/2022] Open
Abstract
To minimize neuromuscular electrical stimulation during electroporation-based treatments, the replacement of long monophasic pulses with bursts of biphasic high-frequency pulses in the range of microseconds was suggested in order to reduce muscle contraction and pain sensation due to pulse application. This treatment modality appeared under the term high-frequency electroporation (HF-EP), which can be potentially used for some clinical applications of electroporation such as electrochemotherapy, gene electrotransfer, and tissue ablation. In cardiac tissue ablation, which utilizes irreversible electroporation, the treatment is being established as Pulsed Field Ablation. While the reduction of muscle contractions was confirmed in multiple in vivo studies, the reduction of pain sensation in humans was not confirmed yet, nor was the relationship between muscle contraction and pain sensation investigated. This is the first study in humans examining pain sensation using biphasic high-frequency electroporation pulses. Twenty-five healthy individuals were subjected to electrical stimulation of the tibialis anterior muscle with biphasic high-frequency pulses in the range of few microseconds and both, symmetric and asymmetric interphase and interpulse delays. Our results confirm that biphasic high-frequency pulses with a pulse width of 1 or 2 µs reduce muscle contraction and pain sensation as opposed to currently used longer monophasic pulses. In addition, interphase and interpulse delays play a significant role in reducing the muscle contraction and/or pain sensation. The study shows that the range of the optimal pulse parameters may be increased depending on the prerequisites of the therapy. However, further evaluation of the biphasic pulse protocols presented herein is necessary to confirm the efficiency of the newly proposed HF-EP.
Collapse
|
8
|
Electroporation and Electrochemotherapy in Gynecological and Breast Cancer Treatment. Molecules 2022; 27:molecules27082476. [PMID: 35458673 PMCID: PMC9026735 DOI: 10.3390/molecules27082476] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2022] [Revised: 03/14/2022] [Accepted: 04/10/2022] [Indexed: 12/24/2022] Open
Abstract
Gynecological carcinomas affect an increasing number of women and are associated with poor prognosis. The gold standard treatment plan is mainly based on surgical resection and subsequent chemotherapy with cisplatin, 5-fluorouracil, anthracyclines, or taxanes. Unfortunately, this treatment is becoming less effective and is associated with many side effects that negatively affect patients’ physical and mental well-being. Electroporation based on tumor exposure to electric pulses enables reduction in cytotoxic drugs dose while increasing their effectiveness. EP-based treatment methods have received more and more interest in recent years and are the subject of a large number of scientific studies. Some of them show promising therapeutic potential without using any cytotoxic drugs or molecules already present in the human body (e.g., calcium electroporation). This literature review aims to present the fundamental mechanisms responsible for the course of EP-based therapies and the current state of knowledge in the field of their application in the treatment of gynecological neoplasms.
Collapse
|
9
|
Wu M, Rubin AE, Dai T, Schloss R, Usta OB, Golberg A, Yarmush M. High-Voltage, Pulsed Electric Fields Eliminate Pseudomonas aeruginosa Stable Infection in a Mouse Burn Model. Adv Wound Care (New Rochelle) 2021; 10:477-489. [PMID: 33066719 PMCID: PMC8260897 DOI: 10.1089/wound.2019.1147] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2019] [Accepted: 10/12/2020] [Indexed: 12/19/2022] Open
Abstract
Objective: The incidence of severe infectious complications after burn injury increases mortality by 40%. However, traditional approaches for managing burn infections are not always effective. High-voltage, pulsed electric field (PEF) treatment shortly after a burn injury has demonstrated an antimicrobial effect in vivo; however, the working parameters and long-term effects of PEF treatment have not yet been investigated. Approach: Nine sets of PEF parameters were investigated to optimize the applied voltage, pulse duration, and frequency or pulse repetition for disinfection of Pseudomonas aeruginosa infection in a stable mouse burn wound model. The bacterial load after PEF administration was monitored for 3 days through bioluminescence imaging. Histological assessments and inflammation response analyses were performed at 1 and 24 h after the therapy. Results: Among all tested PEF parameters, the best disinfection efficacy of P. aeruginosa infection was achieved with a combination of 500 V, 100 μs, and 200 pulses delivered at 3 Hz through two plate electrodes positioned 1 mm apart for up to 3 days after the injury. Histological examinations revealed fewer inflammatory signs in PEF-treated wounds compared with untreated infected burns. Moreover, the expression levels of multiple inflammatory-related cytokines (interleukin [IL]-1α/β, IL-6, IL-10, leukemia inhibitory factor [LIF], and tumor necrosis factor-alpha [TNF-α]), chemokines (macrophage inflammatory protein [MIP]-1α/β and monocyte chemoattractant protein-1 [MCP-1]), and inflammation-related factors (vascular endothelial growth factor [VEGF], macrophage colony-stimulating factor [M-CSF], and granulocyte-macrophage colony-stimulating factor [G-CSF]) were significantly decreased in the infected burn wound after PEF treatment. Innovation: We showed that PEF treatment on infected wounds reduces the P. aeruginosa load and modulates inflammatory responses. Conclusion: The data presented in this study suggest that PEF treatment is a potent candidate for antimicrobial therapy for P. aeruginosa burn infections.
Collapse
Affiliation(s)
- Mengjie Wu
- Department of Orthodontics, The Affiliated Stomatology Hospital, Zhejiang University School of Medicine, Hangzhou, China
- Center of Engineering in Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Andrey Ethan Rubin
- Porter School of Environment and Earth Sciences, Tel Aviv University, Tel Aviv, Israel
| | - Tianhong Dai
- Wellman Center for Photomedicine, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA
- Vaccine and Immunotherapy Center, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Rene Schloss
- Department of Biomedical Engineering, Rutgers University, Piscataway, New Jersey, USA
| | - Osman Berk Usta
- Center of Engineering in Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Alexander Golberg
- Porter School of Environment and Earth Sciences, Tel Aviv University, Tel Aviv, Israel
| | - Martin Yarmush
- Center of Engineering in Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA
- Department of Biomedical Engineering, Rutgers University, Piscataway, New Jersey, USA
- Shriners Burn Hospital for Children, Boston, Massachusetts, USA
| |
Collapse
|
10
|
Aycock KN, Zhao Y, Lorenzo MF, Davalos RV. A Theoretical Argument for Extended Interpulse Delays in Therapeutic High-Frequency Irreversible Electroporation Treatments. IEEE Trans Biomed Eng 2021; 68:1999-2010. [PMID: 33400646 PMCID: PMC8291206 DOI: 10.1109/tbme.2021.3049221] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
High-frequency irreversible electroporation (H-FIRE) is a tissue ablation modality employing bursts of electrical pulses in a positive phase-interphase delay (d1)-negative phase-interpulse delay (d2) pattern. Despite accumulating evidence suggesting the significance of these delays, their effects on therapeutic outcomes from clinically-relevant H-FIRE waveforms have not been studied extensively. OBJECTIVE We sought to determine whether modifications to the delays within H-FIRE bursts could yield a more desirable clinical outcome in terms of ablation volume versus extent of tissue excitation. METHODS We used a modified spatially extended nonlinear node (SENN) nerve fiber model to evaluate excitation thresholds for H-FIRE bursts with varying delays. We then calculated non-thermal tissue ablation, thermal damage, and excitation in a clinically relevant numerical model. RESULTS Excitation thresholds were maximized by shortening d1, and extension of d2 up to 1,000 μs increased excitation thresholds by at least 60% versus symmetric bursts. In the ablation model, long interpulse delays lowered the effective frequency of burst waveforms, modulating field redistribution and reducing heat production. Finally, we demonstrate mathematically that variable delays allow for increased voltages and larger ablations with similar extents of excitation as symmetric waveforms. CONCLUSION Interphase and interpulse delays play a significant role in outcomes resulting from H-FIRE treatment. SIGNIFICANCE Waveforms with short interphase delays (d1) and extended interpulse delays (d2) may improve therapeutic efficacy of H-FIRE as it emerges as a clinical tissue ablation modality.
Collapse
Affiliation(s)
- Kenneth N. Aycock
- Department of Biomedical Engineering and Mechanics, Bioelectromechanical Systems Laboratory at Virginia Tech, Blacksburg, VA 24061 USA
| | - Yajun Zhao
- Department of Biomedical Engineering and Mechanics, Bioelectromechanical Systems Laboratory at Virginia Tech, Blacksburg, VA 24061 USA
| | - Melvin F. Lorenzo
- Department of Biomedical Engineering and Mechanics, Bioelectromechanical Systems Laboratory at Virginia Tech, Blacksburg, VA 24061 USA
| | - Rafael V. Davalos
- Department of Biomedical Engineering and Mechanics, Bioelectromechanical Systems Laboratory at Virginia Tech, Blacksburg, VA 24061 USA
| |
Collapse
|
11
|
Fusco R, Di Bernardo E, D'Alessio V, Salati S, Cadossi M. Reduction of muscle contraction and pain in electroporation-based treatments: An overview. World J Clin Oncol 2021; 12:367-381. [PMID: 34131568 PMCID: PMC8173331 DOI: 10.5306/wjco.v12.i5.367] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/23/2020] [Revised: 03/17/2021] [Accepted: 04/22/2021] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND In the first studies of electrochemotherapy (ECT), small cutaneous metastases were treated and only mild or moderate pain was observed; therefore, pain was not considered a significant issue. As the procedure began to be applied to larger cutaneous metastases, pain was reported more frequently. For that reason, reduction of both muscle contractions and pain have been investigated over the years.
AIM To present an overview of different protocols described in literature that aim to reduce muscle contractions and pain caused by the electroporation (EP) effect in both ECT and irreversible EP treatments.
METHODS Thirty-three studies published between January 1999 and November 2020 were included. Different protocol designs and electrode geometries that reduce patient pain and the number of muscle contractions and their intensity were analysed.
RESULTS The analysis showed that both high frequency and bipolar/biphasic pulses can be used to reduce pain and muscle contractions in patients who undergo EP treatments. Moreover, adequate electrode design can decrease EP-related morbidity. Particularly, needle length, diameter and configuration of the distance between the needles can be optimised so that the muscle volume crossed by the current is reduced as much as possible. Bipolar/biphasic pulses with an inadequate pulse length seem to have a less evident effect on the membrane permeability compared with the standard pulse protocol. For that reason, the number of pulses and the voltage amplitude, as well as the pulse duration and frequency, must be chosen so that the dose of delivered energy guarantees EP efficacy.
CONCLUSION Pain reduction in EP-based treatments can be achieved by appropriately defining the protocol parameters and electrode design. Most results can be achieved with high frequency and/or bipolar/biphasic pulses. However, the efficacy of these alternative protocols remains a crucial point to be assessed further.
Collapse
Affiliation(s)
- Roberta Fusco
- Department of Medical Oncology, IGEA SpA, Carpi 41012, Modena, Italy
| | - Elio Di Bernardo
- Department of Medical Oncology, IGEA SpA, Carpi 41012, Modena, Italy
| | - Valeria D'Alessio
- Department of Medical Oncology, IGEA SpA, Carpi 41012, Modena, Italy
| | - Simona Salati
- Department of Medical Oncology, IGEA SpA, Carpi 41012, Modena, Italy
| | - Matteo Cadossi
- Department of Medical Oncology, IGEA SpA, Carpi 41012, Modena, Italy
| |
Collapse
|
12
|
High-Frequency and High-Voltage Asymmetric Bipolar Pulse Generator for Electroporation Based Technologies and Therapies. ELECTRONICS 2021. [DOI: 10.3390/electronics10101203] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Currently, in high-frequency electroporation, much progress has been made but limited to research groups with custom-made laboratory prototype electroporators. According to the review of electroporators and economic evaluations, there is still an area of pulse parameters that needs to be investigated. The development of an asymmetric bipolar pulse generator with a maximum voltage of 4 kV and minimum duration time of a few hundred nanoseconds, would enable in vivo evaluation of biological effects of high-frequency electroporation pulses. Herein, from a series of most commonly used drivers and optical isolations in high-voltage pulse generators the one with optimal characteristics was used. In addition, the circuit topology of the developed device is described in detail. The developed device is able to generate 4 kV pulses, with theoretical 131 A maximal current and 200 ns minimal pulse duration, the maximal pulse repetition rate is 2 MHz and the burst maximal repetition rate is 1 MHz. The device was tested in vivo. The effectiveness of electrochemotherapy of high-frequency electroporation pulses is compared to “classical” electrochemotherapy pulses. In vivo electrochemotherapy with high-frequency electroporation pulses was at least as effective as with “classical” well-established electric pulses, resulting in 86% and 50% complete responses, respectively. In contrast to previous reports, however, muscle contractions were comparable between the two protocols.
Collapse
|
13
|
Novickij V, Malyško V, Želvys A, Balevičiūtė A, Zinkevičienė A, Novickij J, Girkontaitė I. Electrochemotherapy Using Doxorubicin and Nanosecond Electric Field Pulses: A Pilot in Vivo Study. Molecules 2020; 25:E4601. [PMID: 33050300 PMCID: PMC7587179 DOI: 10.3390/molecules25204601] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2020] [Revised: 10/06/2020] [Accepted: 10/09/2020] [Indexed: 12/23/2022] Open
Abstract
Pulsed electric field (PEF) is frequently used for intertumoral drug delivery resulting in a well-known anticancer treatment-electrochemotherapy. However, electrochemotherapy is associated with microsecond range of electrical pulses, while nanosecond range electrochemotherapy is almost non-existent. In this work, we analyzed the feasibility of nanosecond range pulse bursts for successful doxorubicin-based electrochemotherapy in vivo. The conventional microsecond (1.4 kV/cm × 100 µs × 8) procedure was compared to the nanosecond (3.5 kV/cm × 800 ns × 250) non-thermal PEF-based treatment. As a model, Sp2/0 tumors were developed. Additionally, basic current and voltage measurements were performed to detect the characteristic conductivity-dependent patterns and to serve as an indicator of successful tumor permeabilization both in the nano and microsecond pulse range. It was shown that nano-electrochemotherapy can be the logical evolution of the currently established European Standard Operating Procedures for Electrochemotherapy (ESOPE) protocols, offering better energy control and equivalent treatment efficacy.
Collapse
Affiliation(s)
- Vitalij Novickij
- Faculty of Electronics, Vilnius Gediminas Technical University, 03227 Vilnius, Lithuania; (V.M.); (J.N.)
| | - Veronika Malyško
- Faculty of Electronics, Vilnius Gediminas Technical University, 03227 Vilnius, Lithuania; (V.M.); (J.N.)
| | - Augustinas Želvys
- Department of Immunology, State Research Institute Centre for Innovative Medicine, 08406 Vilnius, Lithuania; (A.Ž.); (A.B.); (A.Z.); (I.G.)
| | - Austėja Balevičiūtė
- Department of Immunology, State Research Institute Centre for Innovative Medicine, 08406 Vilnius, Lithuania; (A.Ž.); (A.B.); (A.Z.); (I.G.)
| | - Auksė Zinkevičienė
- Department of Immunology, State Research Institute Centre for Innovative Medicine, 08406 Vilnius, Lithuania; (A.Ž.); (A.B.); (A.Z.); (I.G.)
| | - Jurij Novickij
- Faculty of Electronics, Vilnius Gediminas Technical University, 03227 Vilnius, Lithuania; (V.M.); (J.N.)
| | - Irutė Girkontaitė
- Department of Immunology, State Research Institute Centre for Innovative Medicine, 08406 Vilnius, Lithuania; (A.Ž.); (A.B.); (A.Z.); (I.G.)
| |
Collapse
|
14
|
Novickij V, Balevičiūtė A, Ruzgys P, Šatkauskas S, Novickij J, Zinkevičienė A, Girkontaitė I. Sub-microsecond electrotransfection using new modality of high frequency electroporation. Bioelectrochemistry 2020; 136:107594. [PMID: 32679337 DOI: 10.1016/j.bioelechem.2020.107594] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2020] [Revised: 06/28/2020] [Accepted: 06/28/2020] [Indexed: 12/21/2022]
Abstract
Micro-millisecond range electric field pulses have been used for decades to facilitate DNA transfer into cells and tissues, while the growing number of clinical trials underline the strong potential of DNA electroporation. In this work, we present new sub-microsecond range protocols and methodology enabling successful electrotransfection in the sub-microsecond range. To facilitate DNA transfer, a 3 kV/60 A and high frequency (1 MHz) sub-microsecond range square wave generator was applied in the study. As a model, Chinese hamster ovary (CHO-K1) cells were used. Sub-microsecond range (300-700 ns) high frequency pulsed electric fields of 2-15 kV/cm were applied. The efficiency of electrotransfection was evaluated using two green fluorescent protein encoding plasmids of different size (3.5 kbp and 4.7 kbp). It was shown that transfection efficiency cannot be effectively improved with increase of the number of pulses after a certain threshold, however, independently on the plasmid size, the proposed sub-microsecond range pulsing methodology (2-5 kV/cm; n = 250) efficiency-wise was equivalent to 1.5 kV/cm × 100 μs × 4 electroporation procedure. The results of the study are useful for further development of in vitro and in vivo methods for effective electrotransfer of DNA using shorter pulses.
Collapse
Affiliation(s)
- Vitalij Novickij
- Faculty of Electronics, Vilnius Gediminas Technical University, Vilnius, Lithuania.
| | - Austėja Balevičiūtė
- State Research Institute Centre for Innovative Medicine, Department of Immunology, Vilnius, Lithuania
| | - Paulius Ruzgys
- Biophysical Research Group, Vytautas Magnus University, Kaunas, Lithuania
| | - Saulius Šatkauskas
- Biophysical Research Group, Vytautas Magnus University, Kaunas, Lithuania
| | - Jurij Novickij
- Faculty of Electronics, Vilnius Gediminas Technical University, Vilnius, Lithuania
| | - Auksė Zinkevičienė
- State Research Institute Centre for Innovative Medicine, Department of Immunology, Vilnius, Lithuania
| | - Irutė Girkontaitė
- State Research Institute Centre for Innovative Medicine, Department of Immunology, Vilnius, Lithuania
| |
Collapse
|
15
|
Pirc E, Reberšek M, Miklavčič D. Functional Requirements and Quality Assurance Necessary for Successful Incorporation of Electroporation-Based Therapies Into Clinical Practice. J Med Device 2020. [DOI: 10.1115/1.4045837] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
Abstract
Electroporation-based therapies have a huge potential for implementation into clinical practice in socioeconomically disadvantaged populations. Currently, the price of electroporators and electrodes is relatively high, but custom low budget devices can be developed. In the paper, we describe three most established applications in medicine, with the focus on the basic mechanisms, which should be taken into account during the development process of a clinical electroporator. Also, typical pulse parameters used in each of the described applications are defined. In the second part of the paper, we describe technical functional requirements for a clinical electroporator and safety guidelines, with the focus on medical device standard. At the end of the paper, the focus moves to a more general problematic, such as quality assurance and the importance of measurement during the pulse delivery, which we firmly believe is necessary for successful electroporation.
Collapse
Affiliation(s)
- Eva Pirc
- Laboratory of Biocybernetics, Faculty of Electrical Engineering, University of Ljubljana, Tržaška cesta 25, Ljubljana 1000, Slovenia
| | - Matej Reberšek
- Laboratory of Biocybernetics, Faculty of Electrical Engineering, University of Ljubljana, Tržaška cesta 25, Ljubljana 1000, Slovenia
| | - Damijan Miklavčič
- Laboratory of Biocybernetics, Faculty of Electrical Engineering, University of Ljubljana, Tržaška cesta 25, Ljubljana 1000, Slovenia
| |
Collapse
|
16
|
Lorenzo MF, Thomas SC, Kani Y, Hinckley J, Lee M, Adler J, Verbridge SS, Hsu FC, Robertson JL, Davalos RV, Rossmeisl JH. Temporal Characterization of Blood-Brain Barrier Disruption with High-Frequency Electroporation. Cancers (Basel) 2019; 11:cancers11121850. [PMID: 31771214 PMCID: PMC6966593 DOI: 10.3390/cancers11121850] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2019] [Revised: 11/21/2019] [Accepted: 11/22/2019] [Indexed: 12/18/2022] Open
Abstract
Treatment of intracranial disorders suffers from the inability to accumulate therapeutic drug concentrations due to protection from the blood–brain barrier (BBB). Electroporation-based therapies have demonstrated the capability of permeating the BBB, but knowledge of the longevity of BBB disruption (BBBD) is limited. In this study, we quantify the temporal, high-frequency electroporation (HFE)-mediated BBBD in an in vivo healthy rat brain model. 40 male Fisher rats underwent HFE treatment; two blunt tipped monopolar electrodes were advanced into the brain and 200 bursts of HFE were delivered at a voltage-to-distance ratio of 600 V/cm. BBBD was verified with contrast enhanced T1W MRI (gadopentetate dimeglumine) and pathologically (Evans blue dye) at time points of 1, 24, 48, 72, and 96 h after HFE. Contrast enhanced T1W scans demonstrated BBBD for 1 to 72 h after HFE but intact BBB at 96 h. Histologically, tissue damage was restricted to electrode insertion tracks. BBBD was induced with minimal muscle contractions and minimal cell death attributed to HFE. Numerical modeling indicated that brief BBBD was induced with low magnitude electric fields, and BBBD duration increased with field strength. These data suggest the spatiotemporal characteristics of HFE-mediated BBBD may be modulated with the locally applied electric field.
Collapse
Affiliation(s)
- Melvin F. Lorenzo
- Bioelectromechanical Systems Laboratory, School of Biomedical Engineering and Sciences, Virginia Tech-Wake Forest University, Blacksburg, VA 24061, USA; (M.F.L.); (M.L.); (R.V.D.)
- Department of Biomedical Engineering and Mechanics, Virginia Tech, Blacksburg, VA 24061, USA; (S.C.T.); (S.S.V.); (J.L.R.)
| | - Sean C. Thomas
- Department of Biomedical Engineering and Mechanics, Virginia Tech, Blacksburg, VA 24061, USA; (S.C.T.); (S.S.V.); (J.L.R.)
| | - Yukitaka Kani
- Department of Small Animal Clinical Sciences, Virginia Tech, Blacksburg, VA 24061, USA; (Y.K.); (J.H.); (J.A.)
| | - Jonathan Hinckley
- Department of Small Animal Clinical Sciences, Virginia Tech, Blacksburg, VA 24061, USA; (Y.K.); (J.H.); (J.A.)
| | - Matthew Lee
- Bioelectromechanical Systems Laboratory, School of Biomedical Engineering and Sciences, Virginia Tech-Wake Forest University, Blacksburg, VA 24061, USA; (M.F.L.); (M.L.); (R.V.D.)
| | - Joy Adler
- Department of Small Animal Clinical Sciences, Virginia Tech, Blacksburg, VA 24061, USA; (Y.K.); (J.H.); (J.A.)
| | - Scott S. Verbridge
- Department of Biomedical Engineering and Mechanics, Virginia Tech, Blacksburg, VA 24061, USA; (S.C.T.); (S.S.V.); (J.L.R.)
| | - Fang-Chi Hsu
- Department of Biostatistics and Data Science, Division of Public Health Sciences, Wake Forest School of Medicine, Winston-Salem, NC 27157, USA;
| | - John L. Robertson
- Department of Biomedical Engineering and Mechanics, Virginia Tech, Blacksburg, VA 24061, USA; (S.C.T.); (S.S.V.); (J.L.R.)
- Department of Small Animal Clinical Sciences, Virginia Tech, Blacksburg, VA 24061, USA; (Y.K.); (J.H.); (J.A.)
| | - Rafael V. Davalos
- Bioelectromechanical Systems Laboratory, School of Biomedical Engineering and Sciences, Virginia Tech-Wake Forest University, Blacksburg, VA 24061, USA; (M.F.L.); (M.L.); (R.V.D.)
- Department of Biomedical Engineering and Mechanics, Virginia Tech, Blacksburg, VA 24061, USA; (S.C.T.); (S.S.V.); (J.L.R.)
| | - John H. Rossmeisl
- Department of Small Animal Clinical Sciences, Virginia Tech, Blacksburg, VA 24061, USA; (Y.K.); (J.H.); (J.A.)
- Correspondence: ; Tel.: +1-540-231-7288
| |
Collapse
|
17
|
Golberg A, Sheviryov J, Solomon O, Anavy L, Yakhini Z. Molecular harvesting with electroporation for tissue profiling. Sci Rep 2019; 9:15750. [PMID: 31673038 PMCID: PMC6823461 DOI: 10.1038/s41598-019-51634-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2019] [Accepted: 10/03/2019] [Indexed: 01/01/2023] Open
Abstract
Recent developments in personalized medicine are based on molecular measurement steps that guide personally adjusted medical decisions. A central approach to molecular profiling consists of measuring DNA, RNA, and/or proteins in tissue samples, most notably in and around tumors. This measurement yields molecular biomarkers that are potentially predictive of response and of tumor type. Current methods in cancer therapy mostly use tissue biopsy as the starting point of molecular profiling. Tissue biopsies involve a physical resection of a small tissue sample, leading to localized tissue injury, bleeding, inflammation and stress, as well as to an increased risk of metastasis. Here we developed a technology for harvesting biomolecules from tissues using electroporation. We show that tissue electroporation, achieved using a combination of high-voltage short pulses, 50 pulses 500 V cm-1, 30 µs, 1 Hz, with low-voltage long pulses 50 pulses 50 V cm-1, 10 ms, delivered at 1 Hz, allows for tissue-specific extraction of RNA and proteins. We specifically tested RNA and protein extraction from excised kidney and liver samples and from excised HepG2 tumors in mice. Further in vivo development of extraction methods based on electroporation can drive novel approaches to the molecular profiling of tumors and of tumor environment and to related diagnosis practices.
Collapse
Affiliation(s)
- Alexander Golberg
- Porter School of Environment and Earth Sciences, Tel Aviv University, Tel Aviv, Israel.
| | - Julia Sheviryov
- Porter School of Environment and Earth Sciences, Tel Aviv University, Tel Aviv, Israel
| | - Oz Solomon
- School of Computer Science, Herzliya Interdisciplinary Center, Herzliya, Israel
| | - Leon Anavy
- Computer Science Department, Technion, Haifa, Israel
| | - Zohar Yakhini
- School of Computer Science, Herzliya Interdisciplinary Center, Herzliya, Israel.
- Computer Science Department, Technion, Haifa, Israel.
| |
Collapse
|
18
|
Byron CR, DeWitt MR, Latouche EL, Davalos RV, Robertson JL. Treatment of Infiltrative Superficial Tumors in Awake Standing Horses Using Novel High-Frequency Pulsed Electrical Fields. Front Vet Sci 2019; 6:265. [PMID: 31475163 PMCID: PMC6705183 DOI: 10.3389/fvets.2019.00265] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2018] [Accepted: 07/30/2019] [Indexed: 12/18/2022] Open
Abstract
Irreversible electroporation is a proven ablation modality for local ablation of soft tissue tumors in animals and humans. However, the strong muscle contractions associated with the electrical impulses (duration, 50–100 μs) requires the use of general anesthesia and, in most situations, application of neuromuscular blockade. As such, this technology is not used in an outpatient setting for ablating common cutaneous tumors (e.g., squamous cell carcinoma or melanoma) in humans or animals. Recently, high-frequency irreversible electroporation (H-FIRE) technology has been developed to enable electroporation of tumors without stimulation of nearby skeletal muscle. H-FIRE administers bursts of electrical pulses (duration, 0.5–2 μs) through bipolar electrodes placed in tumor parenchyma. We hypothesized that H-FIRE could be used to safely ablate superficial tumors in standing, awake horses without the need for general anesthesia. Here, we describe the treatment of superficial tumors in five horses using this novel ablation therapy without the need for general anesthesia. In each case, H-FIRE therapy predictably ablated tumor volume. All patients tolerated the procedure, no complications developed, and veterinary personnel safety was maintained. The H-FIRE treatment may be useful for treatment in veterinary and human patients in an outpatient setting without the need for hospitalization, general anesthesia, and advanced monitoring techniques.
Collapse
Affiliation(s)
- Christopher R Byron
- Department of Large Animal Clinical Sciences, Virginia-Maryland Regional College of Veterinary Medicine, Virginia Tech, Blacksburg, VA, United States
| | - Matthew R DeWitt
- Virginia Tech-Wake Forest School of Biomedical Engineering and Science, College of Engineering, Virginia Tech, Blacksburg, VA, United States
| | - Eduardo L Latouche
- Virginia Tech-Wake Forest School of Biomedical Engineering and Science, College of Engineering, Virginia Tech, Blacksburg, VA, United States
| | - Rafael V Davalos
- Virginia Tech-Wake Forest School of Biomedical Engineering and Science, College of Engineering, Virginia Tech, Blacksburg, VA, United States
| | - John L Robertson
- Virginia Tech-Wake Forest School of Biomedical Engineering and Science, College of Engineering, Virginia Tech, Blacksburg, VA, United States
| |
Collapse
|
19
|
Pulsed electric field inactivation of microorganisms: from fundamental biophysics to synergistic treatments. Appl Microbiol Biotechnol 2019; 103:7917-7929. [DOI: 10.1007/s00253-019-10067-y] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2019] [Revised: 07/25/2019] [Accepted: 07/26/2019] [Indexed: 12/15/2022]
|
20
|
Garcia-Sanchez T, Mercadal B, Polrot M, Muscat A, Sarnago H, Lucia O, Mir LM. Successful Tumor Electrochemotherapy Using Sine Waves. IEEE Trans Biomed Eng 2019; 67:1040-1049. [PMID: 31329545 DOI: 10.1109/tbme.2019.2928645] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
OBJECTIVE The purpose of this work is to assess the ability of sine waves to perform electrochemotherapy (ECT) and to study the dependence of the frequency of the applied sine wave on the treatment efficacy. METHODS A subcutaneous tumor model in mice was used, and the electric field was delivered in combination with bleomycin. Sinusoidal electric fields of different frequencies, amplitudes, and durations were compared to square waves. Computer simulations were additionally performed. RESULTS The results confirmed the ability of a sinusoidal electric field to obtain successful ECT responses. A strong dependence on frequency was obtained. The efficacy of the treatment decreased when the frequency of the sine waves was increased. At low sinusoidal frequency, the efficacy of the treatment is very similar to that obtained with a square wave. The collateral effects such as skin burns and muscle contractions decreased for the highest frequency assayed. CONCLUSION The use of sine wave burst represents a feasible option for the treatment of cancer by ECT. SIGNIFICANCE These results could have important implications for the treatment of cancer in the clinical world where ECT is performed with dc square pulses.
Collapse
|
21
|
The use of high-frequency short bipolar pulses in cisplatin electrochemotherapy in vitro. Radiol Oncol 2019; 53:194-205. [PMID: 31194692 PMCID: PMC6572501 DOI: 10.2478/raon-2019-0025] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2019] [Accepted: 04/23/2019] [Indexed: 12/28/2022] Open
Abstract
Background In electrochemotherapy (ECT), chemotherapeutics are first administered, followed by short 100 μs monopolar pulses. However, these pulses cause pain and muscle contractions. It is thus necessary to administer muscle relaxants, general anesthesia and synchronize pulses with the heart rhythm of the patient, which makes the treatment more complex. It was suggested in ablation with irreversible electroporation, that bursts of short high-frequency bipolar pulses could alleviate these problems. Therefore, we designed our study to verify if it is possible to use high-frequency bipolar pulses (HF-EP pulses) in electrochemotherapy. Materials and methods We performed in vitro experiments on mouse skin melanoma (B16-F1) cells by adding 1–330 μM cisplatin and delivering either (a) eight 100 μs long monopolar pulses, 0.4–1.2 kV/cm, 1 Hz (ECT pulses) or (b) eight bursts at 1 Hz, consisting of 50 bipolar pulses. One bipolar pulse consisted of a series of 1 μs long positive and 1 μs long negative pulse (0.5–5 kV/cm) with a 1 μs delay in-between. Results With both types of pulses, the combination of electric pulses and cisplatin was more efficient in killing cells than cisplatin or electric pulses only. However, we needed to apply a higher electric field in HF-EP (3 kV/cm) than in ECT (1.2 kV/cm) to obtain comparable cytotoxicity. Conclusions It is possible to use HF-EP in electrochemotherapy; however, at the expense of applying higher electric fields than in classical ECT. The results obtained, nevertheless, offer an evidence that HF-EP could be used in electrochemotherapy with potentially alleviated muscle contractions and pain.
Collapse
|
22
|
Low concentrations of acetic and formic acids enhance the inactivation of Staphylococcus aureus and Pseudomonas aeruginosa with pulsed electric fields. BMC Microbiol 2019; 19:73. [PMID: 30943901 PMCID: PMC6448289 DOI: 10.1186/s12866-019-1447-1] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2018] [Accepted: 03/28/2019] [Indexed: 02/07/2023] Open
Abstract
Background Skin infections, particularly caused by drug-resistant pathogens, represent a clinical challenge due to being a frequent cause of morbidity and mortality. The objectives of this study were to examine if low concentrations of acetic and formic acids can increase sensitivity of Staphylococcus aureus and Pseudomonas aeruginosa to pulsed electric field (PEF) and thus, promote a fast and efficient treatment methodology for wound treatment. Results We have shown that the combination of PEF (10–30 kV/cm) with organic acids (0.1% formic and acetic acids) increased the bactericidal properties of treatment. The effect was apparent for both acids. The proposed methodology allowed to reduce the energy of electrical pulses and the inhibitory concentrations of acids, while still maintain high efficiency of bacteria eradication. Conclusions Application of weak organic acids as bactericidal agents has many advantages over antibiotics because they do not trigger development of drug-resistance in bacteria. The combination with PEF can make the treatment effective even against biofilms. The results of this study are particularly useful for the development of new methodologies for the treatment of extreme cases of wound infections when the chemical treatment is no longer effective or hinders wound healing.
Collapse
|
23
|
Rubin AE, Usta OB, Schloss R, Yarmush M, Golberg A. Selective Inactivation of Pseudomonas aeruginosa and Staphylococcus epidermidis with Pulsed Electric Fields and Antibiotics. Adv Wound Care (New Rochelle) 2019; 8:136-148. [PMID: 31737412 DOI: 10.1089/wound.2018.0819] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2018] [Accepted: 10/15/2018] [Indexed: 01/17/2023] Open
Abstract
Objective: Increasing numbers of multidrug-resistant bacteria make many antibiotics ineffective; therefore, new approaches to combat microbial infections are needed. In addition, antibiotics are not selective-they kill pathogenic organisms as well as organisms that could positively contribute to wound healing (bio flora). Approach: Here we report on selective inactivation of Pseudomonas aeruginosa and Staphylococcus epidermidis, potential pathogens involved in wound infections with pulsed electric fields (PEFs) and antibiotics (mix of penicillin, streptomycin, and nystatin). Results: Using a Taguchi experimental design in vitro, we found that, under similar electric field strengths, the pulse duration is the most important parameter for P. aeruginosa inactivation, followed by the number of pulses and pulse frequency. P. aeruginosa, a potential severe pathogen, is more sensitive than the less pathogenic S. epidermidis to PEF (alone or in combination with antibiotics). Applying 200 pulses with a duration of 60 μs at 2.8 Hz, the minimum electric fields of 308.8 ± 28.3 and 378.4 ± 12.9 V/mm were required to inactive P. aeruginosa and S. epidermidis, respectively. Addition of antibiotics reduced the threshold for minimum electric fields required to inactivate the bacteria. Innovation: This study provides essential information, such as critical electric field parameters for bacteria inactivation, required for developing in vivo treatment and clinical protocols for using PEF for wound healing. Conclusion: A combination of PEFs with antibiotics reduces the electric field threshold required for bacteria disinfection. Such an approach simplifies devices required to disinfect large areas of infected wounds.
Collapse
Affiliation(s)
- Andrey Ethan Rubin
- Porter School of Environment and Earth Sciences, Tel Aviv University Ramat Aviv, Tel Aviv, Israel
| | - Osman Berk Usta
- Center for Engineering in Medicine, Massachusetts General Hospital Shriners Burn Hospital for Children and Harvard Medical School, Boston, Massachusetts
| | - Rene Schloss
- Department of Biomedical Engineering, Rutgers University, Piscataway, New Jersey
| | - Martin Yarmush
- Center for Engineering in Medicine, Massachusetts General Hospital Shriners Burn Hospital for Children and Harvard Medical School, Boston, Massachusetts
- Department of Biomedical Engineering, Rutgers University, Piscataway, New Jersey
| | - Alexander Golberg
- Porter School of Environment and Earth Sciences, Tel Aviv University Ramat Aviv, Tel Aviv, Israel
| |
Collapse
|
24
|
Novickij V, Švedienė J, Paškevičius A, Markovskaja S, Lastauskienė E, Zinkevičienė A, Girkontaitė I, Novickij J. Induction of Different Sensitization Patterns of MRSA to Antibiotics Using Electroporation. Molecules 2018; 23:molecules23071799. [PMID: 30037022 PMCID: PMC6100619 DOI: 10.3390/molecules23071799] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2018] [Revised: 07/18/2018] [Accepted: 07/20/2018] [Indexed: 01/04/2023] Open
Abstract
Treatment of bacteria-associated infections is complicated and antibiotic treatment alone is often inadequate to overcome biofilm infections. Physical methods allow overcoming this problem and propose solutions that are non-dependent on drug resistance. In this work, we investigated the feasibility of pulsed electric fields for sensitization of MRSA to common antibiotics. We analyzed the efficacy of inactivation of methicillin-resistant Staphylococcus aureus in 5–20 kV/cm electric field separately and in combination with gentamicin, doxycycline, ciprofloxacin, sulfamethoxazole, and vancomycin. Combined treatment allowed using up to 1000-fold smaller concentrations of antibiotics to induce the same inactivation of S. aureus.
Collapse
Affiliation(s)
- Vitalij Novickij
- Institute of High Magnetic Fields, Vilnius Gediminas Technical University, Naugarduko st. 41, 03227 Vilnius, Lithuania.
| | - Jurgita Švedienė
- Laboratory of Biodeterioration Research, Nature Research Centre, Akademijos st. 2, 08412 Vilnius, Lithuania.
| | - Algimantas Paškevičius
- Laboratory of Biodeterioration Research, Nature Research Centre, Akademijos st. 2, 08412 Vilnius, Lithuania.
- Laboratory of Microbiology of the Centre of Laboratory Medicine, Vilnius University Hospital Santariškių Clinics, Santariskiu g. 2, 08406 Vilnius, Lithuania.
| | - Svetlana Markovskaja
- Laboratory of Mycology, Nature Research Centre, Žaliųjų ežerų st. 49, 08406 Vilnius, Lithuania.
| | - Eglė Lastauskienė
- Department of Microbiology and Biotechnology, Vilnius University, Sauletekio al. 7, 10257 Vilnius, Lithuania.
| | - Auksė Zinkevičienė
- State Research Institute Centre for Innovative Medicine, Department of Immunology, Santariškių st. 5, 08406 Vilnius, Lithuania.
| | - Irutė Girkontaitė
- State Research Institute Centre for Innovative Medicine, Department of Immunology, Santariškių st. 5, 08406 Vilnius, Lithuania.
| | - Jurij Novickij
- Institute of High Magnetic Fields, Vilnius Gediminas Technical University, Naugarduko st. 41, 03227 Vilnius, Lithuania.
| |
Collapse
|
25
|
Dermol-Černe J, Miklavčič D, Reberšek M, Mekuč P, Bardet SM, Burke R, Arnaud-Cormos D, Leveque P, O'Connor R. Plasma membrane depolarization and permeabilization due to electric pulses in cell lines of different excitability. Bioelectrochemistry 2018; 122:103-114. [PMID: 29621662 DOI: 10.1016/j.bioelechem.2018.03.011] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2017] [Revised: 02/13/2018] [Accepted: 03/19/2018] [Indexed: 12/18/2022]
Abstract
In electroporation-based medical treatments, excitable tissues are treated, either intentionally (irreversible electroporation of brain cancer, gene electrotransfer or ablation of the heart muscle, gene electrotransfer of skeletal muscles), or unintentionally (excitable tissues near the target area). We investigated how excitable and non-excitable cells respond to electric pulses, and if electroporation could be an effective treatment of the tumours of the central nervous system. For three non-excitable and one excitable cell line, we determined a strength-duration curve for a single pulse of 10ns-10ms. The threshold for depolarization decreased with longer pulses and was higher for excitable cells. We modelled the response with the Lapicque curve and the Hodgkin-Huxley model. At 1μs a plateau of excitability was reached which could explain why high-frequency irreversible electroporation (H-FIRE) electroporates but does not excite cells. We exposed cells to standard electrochemotherapy parameters (8×100μs pulses, 1Hz, different voltages). Cells behaved similarly which indicates that electroporation most probably occurs at the level of lipid bilayer, independently of the voltage-gated channels. These results could be used for optimization of electric pulses to achieve maximal permeabilization and minimal excitation/pain sensation. In the future, it should be established whether the in vitro depolarization correlates to nerve/muscle stimulation and pain sensation in vivo.
Collapse
Affiliation(s)
- Janja Dermol-Černe
- University of Ljubljana, Faculty of Electrical Engineering, Tržaška cesta 25, SI-1000 Ljubljana, Slovenia.
| | - Damijan Miklavčič
- University of Ljubljana, Faculty of Electrical Engineering, Tržaška cesta 25, SI-1000 Ljubljana, Slovenia.
| | - Matej Reberšek
- University of Ljubljana, Faculty of Electrical Engineering, Tržaška cesta 25, SI-1000 Ljubljana, Slovenia.
| | - Primož Mekuč
- University of Ljubljana, Faculty of Electrical Engineering, Tržaška cesta 25, SI-1000 Ljubljana, Slovenia
| | - Sylvia M Bardet
- University of Limoges, CNRS, XLIM, UMR 7252, F-87000 Limoges, France.
| | - Ryan Burke
- University of Limoges, CNRS, XLIM, UMR 7252, F-87000 Limoges, France
| | | | - Philippe Leveque
- University of Limoges, CNRS, XLIM, UMR 7252, F-87000 Limoges, France.
| | - Rodney O'Connor
- École des Mines de Saint-Étienne, Department of Bioelectronics, Georges Charpak Campus, Centre Microélectronique de Provence, 880 Route de Mimet, 13120 Gardanne, France.
| |
Collapse
|
26
|
High frequency electroporation efficiency is under control of membrane capacitive charging and voltage potential relaxation. Bioelectrochemistry 2018; 119:92-97. [DOI: 10.1016/j.bioelechem.2017.09.006] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2017] [Revised: 09/13/2017] [Accepted: 09/13/2017] [Indexed: 01/13/2023]
|
27
|
Mercadal B, Arena CB, Davalos RV, Ivorra A. Avoiding nerve stimulation in irreversible electroporation: a numerical modeling study. Phys Med Biol 2017; 62:8060-8079. [PMID: 28901954 DOI: 10.1088/1361-6560/aa8c53] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Electroporation based treatments consist in applying one or multiple high voltage pulses to the tissues to be treated. As an undesired side effect, these pulses cause electrical stimulation of excitable tissues such as nerves and muscles. This increases the complexity of the treatments and may pose a risk to the patient. To minimize electrical stimulation during electroporation based treatments, it has been proposed to replace the commonly used monopolar pulses by bursts of short bipolar pulses. In the present study, we have numerically analyzed the rationale for such approach. We have compared different pulsing protocols in terms of their electroporation efficacy and their capability of triggering action potentials in nerves. For that, we have developed a modeling framework that combines numerical models of nerve fibers and experimental data on irreversible electroporation. Our results indicate that, by replacing the conventional relatively long monopolar pulses by bursts of short bipolar pulses, it is possible to ablate a large tissue region without triggering action potentials in a nearby nerve. Our models indicate that this is possible because, as the pulse length of these bipolar pulses is reduced, the stimulation thresholds raise faster than the irreversible electroporation thresholds. We propose that this different dependence on the pulse length is due to the fact that transmembrane charging for nerve fibers is much slower than that of cells treated by electroporation because of their geometrical differences.
Collapse
Affiliation(s)
- Borja Mercadal
- Department of Information and Communication Technologies, Universitat Pompeu Fabra, Roc Boronat, 138, 08018 Barcelona, Spain
| | | | | | | |
Collapse
|
28
|
Yao C, Dong S, Zhao Y, Lv Y, Liu H, Gong L, Ma J, Wang H, Sun Y. Bipolar Microsecond Pulses and Insulated Needle Electrodes for Reducing Muscle Contractions During Irreversible Electroporation. IEEE Trans Biomed Eng 2017; 64:2924-2937. [PMID: 28391185 DOI: 10.1109/tbme.2017.2690624] [Citation(s) in RCA: 46] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
OBJECTIVE To minimize the effect of muscle contractions during irreversible electroporation (IRE), this paper attempts to research the ablation effect and muscle contractions by applying high-frequency IRE (H-FIRE) ablation to liver tissue in vivo. METHODS An insulated needle electrode was produced by painting an insulating coating on the outer surface of the needle electrode tip. A series of experiments were conducted using insulated needle electrodes and traditional needle electrodes to apply H-FIRE pulses and traditional monopolar IRE pulses to rabbit liver tissues. The finite element model of the rabbit liver tissue was established to determine the lethal thresholds of H-FIRE in liver tissues. Muscle contractions were measured by an accelerometer. RESULTS With increased constitutive pulse width and pulse voltage, the ablation area and muscle contraction strength are also increased, which can be used to optimize the ablation parameters of H-FIRE. Under the same pulse parameters, the ablation areas are similar for the two types of electrodes, and the ablation region has a clear boundary. H-FIRE and insulated needle electrodes can mitigate the extent of muscle contractions. The lethal thresholds of H-FIRE in rabbit liver tissues were determined. CONCLUSION This paper describes the relationships between the ablation area, muscle contractions, and pulse parameters; the designed insulated needle electrodes can be used in IRE for reducing muscle contraction. SIGNIFICANCE The study provides guidance for treatment planning and reducing muscle contractions in the clinical application of H-FIRE.
Collapse
|
29
|
Golberg A, Villiger M, Khan S, Quinn KP, Lo WCY, Bouma BE, Mihm MC, Austen WG, Yarmush ML. Preventing Scars after Injury with Partial Irreversible Electroporation. J Invest Dermatol 2016; 136:2297-2304. [PMID: 27393126 DOI: 10.1016/j.jid.2016.06.620] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2016] [Revised: 06/02/2016] [Accepted: 06/11/2016] [Indexed: 12/16/2022]
Abstract
Preventing the formation of hypertrophic scars, especially those that are a result of major trauma or burns, would have enormous impact in the fields of regenerative and trauma medicine. In this report, we introduce a noninvasive method to prevent scarring based on nonthermal partial irreversible electroporation. Contact burn injuries in rats were treated with varying treatment parameters to optimize the treatment protocol. Scar surface area and structural properties of the scar were assessed with histology and non-invasive, longitudinal imaging with polarization-sensitive optical coherence tomography. We found that partial irreversible electroporation using 200 pulses of 250 V and 70 μs duration, delivered at 3 Hz every 20 days during a total of five therapy sessions after the initial burn injury, resulted in a 57.9% reduction of the scar area compared with untreated scars and structural features approaching those of normal skin. Unlike humans, rats do not develop hypertrophic scars. Therefore, the use of a rat animal model is the limiting factor of this work.
Collapse
Affiliation(s)
- Alexander Golberg
- Center for Engineering in Medicine, Department of Surgery, Massachusetts General Hospital, Harvard Medical School, and the Shriners Burns Hospital, Boston, Massachusetts, USA; Porter School of Environmental Studies, Tel Aviv University, Tel Aviv, Israel.
| | - Martin Villiger
- Wellman Center for Photomedicine, Massachusetts General Hospital and Harvard Medical School, 50 Blossom Street, Boston, Massachusetts, USA
| | - Saiqa Khan
- Department of Surgery, Division of Plastic and Reconstructive Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Kyle P Quinn
- Department of Biomedical Engineering, University of Arkansas, Fayetteville, Arkansas, USA
| | - William C Y Lo
- Wellman Center for Photomedicine, Massachusetts General Hospital and Harvard Medical School, 50 Blossom Street, Boston, Massachusetts, USA; Harvard-Massachusetts Institute of Technology Division of Health Sciences and Technology, Cambridge, Massachusetts, USA
| | - Brett E Bouma
- Wellman Center for Photomedicine, Massachusetts General Hospital and Harvard Medical School, 50 Blossom Street, Boston, Massachusetts, USA; Harvard-Massachusetts Institute of Technology Division of Health Sciences and Technology, Cambridge, Massachusetts, USA
| | - Martin C Mihm
- Department of Dermatology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA
| | - William G Austen
- Department of Surgery, Division of Plastic and Reconstructive Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Martin L Yarmush
- Center for Engineering in Medicine, Department of Surgery, Massachusetts General Hospital, Harvard Medical School, and the Shriners Burns Hospital, Boston, Massachusetts, USA; Department of Biomedical Engineering, Rutgers University, Piscataway, NJ
| |
Collapse
|
30
|
Gibot L, Rols MP. Gene transfer by pulsed electric field is highly promising in cutaneous wound healing. Expert Opin Biol Ther 2015; 16:67-77. [DOI: 10.1517/14712598.2016.1098615] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
|
31
|
Sano MB, Arena CB, Bittleman KR, DeWitt MR, Cho HJ, Szot CS, Saur D, Cissell JM, Robertson J, Lee YW, Davalos RV. Bursts of Bipolar Microsecond Pulses Inhibit Tumor Growth. Sci Rep 2015; 5:14999. [PMID: 26459930 PMCID: PMC4602310 DOI: 10.1038/srep14999] [Citation(s) in RCA: 75] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2015] [Accepted: 09/02/2015] [Indexed: 02/06/2023] Open
Abstract
Irreversible electroporation (IRE) is an emerging focal therapy which is demonstrating utility in the treatment of unresectable tumors where thermal ablation techniques are contraindicated. IRE uses ultra-short duration, high-intensity monopolar pulsed electric fields to permanently disrupt cell membranes within a well-defined volume. Though preliminary clinical results for IRE are promising, implementing IRE can be challenging due to the heterogeneous nature of tumor tissue and the unintended induction of muscle contractions. High-frequency IRE (H-FIRE), a new treatment modality which replaces the monopolar IRE pulses with a burst of bipolar pulses, has the potential to resolve these clinical challenges. We explored the pulse-duration space between 250 ns and 100 μs and determined the lethal electric field intensity for specific H-FIRE protocols using a 3D tumor mimic. Murine tumors were exposed to 120 bursts, each energized for 100 μs, containing individual pulses 1, 2, or 5 μs in duration. Tumor growth was significantly inhibited and all protocols were able to achieve complete regressions. The H-FIRE protocol substantially reduces muscle contractions and the therapy can be delivered without the need for a neuromuscular blockade. This work shows the potential for H-FIRE to be used as a focal therapy and merits its investigation in larger pre-clinical models.
Collapse
Affiliation(s)
- Michael B. Sano
- School of Biomedical Engineering and Sciences, Virginia Tech, USA
- Department of Radiation Oncology, Division of Radiation Physics, Stanford University, USA
| | | | | | | | - Hyung J. Cho
- School of Biomedical Engineering and Sciences, Virginia Tech, USA
| | | | | | | | - John Robertson
- School of Biomedical Engineering and Sciences, Virginia Tech, USA
| | - Yong W. Lee
- School of Biomedical Engineering and Sciences, Virginia Tech, USA
| | | |
Collapse
|
32
|
Abstract
Emerging bacterial resistance renders many antibiotics ineffective, making alternative strategies of wound disinfection important. Here the authors report on a new, physical burn wound disinfection method: pulsed electric fields (PEFs). High voltage, short PEFs create nonthermal, permanent damage to cell membranes, possibly by irreversible electroporation. In medicine, PEF technology has recently been used for nonthermal ablation of solid tumors. The authors have expanded the spectrum of PEF applications in medicine to burn wound disinfection. A third-degree burn was induced on the dorsal skin of C57BL/6 mice. Immediately after the injury, the burn wound was infected with Acinetobacter baumannii expressing the luxCDABE operon. Thirty minutes after infection, the infected areas were treated with 80 pulses delivered at 500 V/mm, 70 μs, 1 Hz. The authors used bioluminescence to quantify bacteria on skin. Three animals were used for each experimental condition. PEFs were effective in the disinfection of infected burned murine skin. The bacterial load reduction correlated with the number of delivered pulses. Forty pulses of 500 V/mm led to a 2.04 ± 0.29 Log10 reduction in bacterial load; 80 pulses led to the immediate 5.53 ± 0.30 Log10 reduction. Three hours after PEF, the bacterial reduction of the skin treated with 500 V/mm, 80 pulses was 4.91 ± 0.71 Log10. The authors introduce a new method of wound disinfection using high voltage, short PEFs. They believe that PEF technology may represent an important alternative to antibiotics in addressing bacterial contamination of wounds, particularly those contaminated with multidrug-resistant bacteria.
Collapse
|
33
|
Khan SI, Blumrosen G, Vecchio D, Golberg A, McCormack MC, Yarmush ML, Hamblin MR, Austen WG. Eradication of multidrug-resistant pseudomonas biofilm with pulsed electric fields. Biotechnol Bioeng 2015; 113:643-650. [PMID: 26332437 DOI: 10.1002/bit.25818] [Citation(s) in RCA: 46] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2015] [Revised: 08/10/2015] [Accepted: 08/23/2015] [Indexed: 01/09/2023]
Abstract
Biofilm formation is a significant problem, accounting for over eighty percent of microbial infections in the body. Biofilm eradication is problematic due to increased resistance to antibiotics and antimicrobials as compared to planktonic cells. The purpose of this study was to investigate the effect of Pulsed Electric Fields (PEF) on biofilm-infected mesh. Prolene mesh was infected with bioluminescent Pseudomonas aeruginosa and treated with PEF using a concentric electrode system to derive, in a single experiment, the critical electric field strength needed to kill bacteria. The effect of the electric field strength and the number of pulses (with a fixed pulse length duration and frequency) on bacterial eradication was investigated. For all experiments, biofilm formation and disruption were confirmed with bioluminescent imaging and Scanning Electron Microscopy (SEM). Computation and statistical methods were used to analyze treatment efficiency and to compare it to existing theoretical models. In all experiments 1500 V are applied through a central electrode, with pulse duration of 50 μs, and pulse delivery frequency of 2 Hz. We found that the critical electric field strength (Ecr) needed to eradicate 100-80% of bacteria in the treated area was 121 ± 14 V/mm when 300 pulses were applied, and 235 ± 6.1 V/mm when 150 pulses were applied. The area at which 100-80% of bacteria were eradicated was 50.5 ± 9.9 mm(2) for 300 pulses, and 13.4 ± 0.65 mm(2) for 150 pulses. 80% threshold eradication was not achieved with 100 pulses. The results indicate that increased efficacy of treatment is due to increased number of pulses delivered. In addition, we that showed the bacterial death rate as a function of the electrical field follows the statistical Weibull model for 150 and 300 pulses. We hypothesize that in the clinical setting, combining systemic antibacterial therapy with PEF will yield a synergistic effect leading to improved eradication of mesh infections.
Collapse
Affiliation(s)
- Saiqa I Khan
- Division of Plastic and Reconstructive Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts 02114
| | - Gaddi Blumrosen
- Department of Computer Science, Tel Aviv University, Tel Aviv, Israel
| | - Daniela Vecchio
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts 02114.,Department of Dermatology, Harvard Medical School, Boston, Massachusetts 02115
| | - Alexander Golberg
- Center for Engineering in Medicine, Department of Surgery, Massachusetts General Hospital, Harvard Medical School, and the Shriners Burns Hospital, Boston, Massachusetts 02114.,Porter School of Environmental Studies, Tel Aviv University, Tel Aviv, Israel
| | - Michael C McCormack
- Division of Plastic and Reconstructive Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts 02114
| | - Martin L Yarmush
- Center for Engineering in Medicine, Department of Surgery, Massachusetts General Hospital, Harvard Medical School, and the Shriners Burns Hospital, Boston, Massachusetts 02114.,Department of Biomedical Engineering, Rutgers University, Piscataway, New Jersey 08854
| | - Michael R Hamblin
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts 02114.,Department of Dermatology, Harvard Medical School, Boston, Massachusetts 02115.,Harvard-MIT Division of Health Sciences and Technology, Cambridge, Massachusetts 02139
| | - William G Austen
- Division of Plastic and Reconstructive Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts 02114
| |
Collapse
|
34
|
Skin rejuvenation with non-invasive pulsed electric fields. Sci Rep 2015; 5:10187. [PMID: 25965851 PMCID: PMC4428072 DOI: 10.1038/srep10187] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2014] [Accepted: 03/19/2015] [Indexed: 01/09/2023] Open
Abstract
Degenerative skin diseases affect one third of individuals over the age of sixty. Current therapies use various physical and chemical methods to rejuvenate skin; but since the therapies affect many tissue components including cells and extracellular matrix, they may also induce significant side effects, such as scarring. Here we report on a new, non-invasive, non-thermal technique to rejuvenate skin with pulsed electric fields. The fields destroy cells while simultaneously completely preserving the extracellular matrix architecture and releasing multiple growth factors locally that induce new cells and tissue growth. We have identified the specific pulsed electric field parameters in rats that lead to prominent proliferation of the epidermis, formation of microvasculature, and secretion of new collagen at treated areas without scarring. Our results suggest that pulsed electric fields can improve skin function and thus can potentially serve as a novel non-invasive skin therapy for multiple degenerative skin diseases.
Collapse
|
35
|
Yarmush ML, Golberg A, Serša G, Kotnik T, Miklavčič D. Electroporation-Based Technologies for Medicine: Principles, Applications, and Challenges. Annu Rev Biomed Eng 2014; 16:295-320. [DOI: 10.1146/annurev-bioeng-071813-104622] [Citation(s) in RCA: 519] [Impact Index Per Article: 47.2] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Affiliation(s)
- Martin L. Yarmush
- Center for Engineering in Medicine, Department of Surgery, Massachusetts General Hospital, Harvard Medical School and Shriners Burn Hospital for Children, Boston, Massachusetts 02114; email (M.L.Y.):
- Department of Biomedical Engineering, Rutgers University, Piscataway, New Jersey 08854;
| | - Alexander Golberg
- Center for Engineering in Medicine, Department of Surgery, Massachusetts General Hospital, Harvard Medical School and Shriners Burn Hospital for Children, Boston, Massachusetts 02114; email (M.L.Y.):
| | - Gregor Serša
- Department of Experimental Oncology, Institute of Oncology Ljubljana, SI-1000 Ljubljana, Slovenia
| | - Tadej Kotnik
- Department of Biomedical Engineering, Faculty of Electrical Engineering, University of Ljubljana, SI-1000 Ljubljana, Slovenia;
| | - Damijan Miklavčič
- Department of Biomedical Engineering, Faculty of Electrical Engineering, University of Ljubljana, SI-1000 Ljubljana, Slovenia;
| |
Collapse
|
36
|
Jourabchi N, Beroukhim K, Tafti BA, Kee ST, Lee EW. Irreversible electroporation (NanoKnife) in cancer treatment. GASTROINTESTINAL INTERVENTION 2014. [DOI: 10.1016/j.gii.2014.02.002] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
37
|
Pavliha D, Kos B, Marčan M, Zupanič A, Serša G, Miklavčič D. Planning of electroporation-based treatments using Web-based treatment-planning software. J Membr Biol 2013; 246:833-42. [PMID: 23780414 DOI: 10.1007/s00232-013-9567-2] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2013] [Accepted: 05/31/2013] [Indexed: 12/12/2022]
Abstract
Electroporation-based treatment combining high-voltage electric pulses and poorly permanent cytotoxic drugs, i.e., electrochemotherapy (ECT), is currently used for treating superficial tumor nodules by following standard operating procedures. Besides ECT, another electroporation-based treatment, nonthermal irreversible electroporation (N-TIRE), is also efficient at ablating deep-seated tumors. To perform ECT or N-TIRE of deep-seated tumors, following standard operating procedures is not sufficient and patient-specific treatment planning is required for successful treatment. Treatment planning is required because of the use of individual long-needle electrodes and the diverse shape, size and location of deep-seated tumors. Many institutions that already perform ECT of superficial metastases could benefit from treatment-planning software that would enable the preparation of patient-specific treatment plans. To this end, we have developed a Web-based treatment-planning software for planning electroporation-based treatments that does not require prior engineering knowledge from the user (e.g., the clinician). The software includes algorithms for automatic tissue segmentation and, after segmentation, generation of a 3D model of the tissue. The procedure allows the user to define how the electrodes will be inserted. Finally, electric field distribution is computed, the position of electrodes and the voltage to be applied are optimized using the 3D model and a downloadable treatment plan is made available to the user.
Collapse
Affiliation(s)
- Denis Pavliha
- Faculty of Electrical Engineering, University of Ljubljana, Tržaška c. 25, SI-1000, Ljubljana, Slovenia,
| | | | | | | | | | | |
Collapse
|
38
|
Golberg A, Bei M, Sheridan RL, Yarmush ML. Regeneration and control of human fibroblast cell density by intermittently delivered pulsed electric fields. Biotechnol Bioeng 2013; 110:1759-68. [DOI: 10.1002/bit.24831] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2012] [Revised: 12/20/2012] [Accepted: 12/21/2012] [Indexed: 12/20/2022]
|
39
|
Golberg A, Yarmush ML. Nonthermal irreversible electroporation: fundamentals, applications, and challenges. IEEE Trans Biomed Eng 2013; 60:707-14. [PMID: 23314769 DOI: 10.1109/tbme.2013.2238672] [Citation(s) in RCA: 117] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Tissue ablation is an essential procedure for the treatment of many diseases. In the last decade, a nonthermal tissue ablation using intensive pulsed electric fields, called nonthermal irreversible electroporation (NTIRE), has rapidly emerged. The exact mechanisms responsible for cell death by NTIRE, however, are currently unknown. Nevertheless, the technique's remarkable ability to ablate tissue in the proximity of larger blood vessels, to preserve tissue architecture, short procedure duration, and shortened postoperative recovery period rapidly moved NTIRE from bench to bed side. This work provides an overview on the development of NTIRE, its current state-of-the-art, challenges, and future needs.
Collapse
Affiliation(s)
- Alexander Golberg
- Center for Engineering in Medicine, Department of Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA.
| | | |
Collapse
|
40
|
Golberg A, Bei M, Sheridan RL, Yarmush ML. Regeneration and control of human fibroblast cell density by intermittently delivered pulsed electric fields. Biotechnol Bioeng 2013. [DOI: 10.1002/bit.24832] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|