1
|
Urhuț MC, Săndulescu LD, Streba CT, Mămuleanu M, Ciocâlteu A, Cazacu SM, Dănoiu S. Diagnostic Performance of an Artificial Intelligence Model Based on Contrast-Enhanced Ultrasound in Patients with Liver Lesions: A Comparative Study with Clinicians. Diagnostics (Basel) 2023; 13:3387. [PMID: 37958282 PMCID: PMC10650544 DOI: 10.3390/diagnostics13213387] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2023] [Revised: 10/29/2023] [Accepted: 11/02/2023] [Indexed: 11/15/2023] Open
Abstract
Contrast-enhanced ultrasound (CEUS) is widely used in the characterization of liver tumors; however, the evaluation of perfusion patterns using CEUS has a subjective character. This study aims to evaluate the accuracy of an automated method based on CEUS for classifying liver lesions and to compare its performance with that of two experienced clinicians. The system used for automatic classification is based on artificial intelligence (AI) algorithms. For an interpretation close to the clinical setting, both clinicians knew which patients were at high risk for hepatocellular carcinoma (HCC), but only one was aware of all the clinical data. In total, 49 patients with 59 liver tumors were included. For the benign and malignant classification, the AI model outperformed both clinicians in terms of specificity (100% vs. 93.33%); still, the sensitivity was lower (74% vs. 93.18% vs. 90.91%). In the second stage of multiclass diagnosis, the automatic model achieved a diagnostic accuracy of 69.93% for HCC and 89.15% for liver metastases. Readers demonstrated greater diagnostic accuracy for HCC (83.05% and 79.66%) and liver metastases (94.92% and 96.61%) compared to the AI system; however, both were experienced sonographers. The AI model could potentially assist and guide less-experienced clinicians to discriminate malignant from benign liver tumors with high accuracy and specificity.
Collapse
Affiliation(s)
- Marinela-Cristiana Urhuț
- Department of Gastroenterology, Emergency County Hospital of Craiova, Doctoral School, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania;
| | - Larisa Daniela Săndulescu
- Department of Gastroenterology, Research Center of Gastroenterology and Hepatology, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania; (C.T.S.); (A.C.); (S.M.C.)
| | - Costin Teodor Streba
- Department of Gastroenterology, Research Center of Gastroenterology and Hepatology, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania; (C.T.S.); (A.C.); (S.M.C.)
- Department of Pulmonology, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania
- Oncometrics S.R.L., 200677 Craiova, Romania;
| | - Mădălin Mămuleanu
- Oncometrics S.R.L., 200677 Craiova, Romania;
- Department of Automatic Control and Electronics, University of Craiova, 200585 Craiova, Romania
| | - Adriana Ciocâlteu
- Department of Gastroenterology, Research Center of Gastroenterology and Hepatology, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania; (C.T.S.); (A.C.); (S.M.C.)
| | - Sergiu Marian Cazacu
- Department of Gastroenterology, Research Center of Gastroenterology and Hepatology, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania; (C.T.S.); (A.C.); (S.M.C.)
| | - Suzana Dănoiu
- Department of Pathophysiology, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania;
| |
Collapse
|
2
|
Davis L, Back SJ. Microbubbles in the belly: optimizing the protocol for contrast-enhanced ultrasound of the pediatric abdomen. Pediatr Radiol 2022:10.1007/s00247-022-05464-x. [PMID: 36006474 DOI: 10.1007/s00247-022-05464-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/08/2022] [Revised: 06/20/2022] [Accepted: 07/19/2022] [Indexed: 11/30/2022]
Abstract
Intravenous contrast-enhanced ultrasound (CEUS) can serve as a diagnostic or problem-solving tool in pediatric imaging. CEUS of abdominal solid organs has been reported for a number of indications. The approach to the examination broadly falls into two categories: evaluation of a focal lesion or surveillance of an organ or organs for lesions or perfusion abnormalities. A consistent, technical imaging protocol for both of these clinical scenarios facilitates integration of routine use of CEUS in an imaging department. Here we review the CEUS imaging protocols for abdominal organs in children, including technical and solid-organ-specific considerations.
Collapse
Affiliation(s)
- Lauramay Davis
- Institute of Nuclear Medicine, University College Hospital, London, UK
| | - Susan J Back
- Department of Radiology, Children's Hospital of Philadelphia, 3401 Civic Center Blvd., Philadelphia, PA, 19104, USA. .,Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA.
| |
Collapse
|
3
|
Hwang M, Back SJ, Didier RA, Lorenz N, Morgan TA, Poznick L, Steffgen L, Sridharan A. Pediatric contrast-enhanced ultrasound: optimization of techniques and dosing. Pediatr Radiol 2021; 51:2147-2160. [PMID: 32955599 DOI: 10.1007/s00247-020-04812-z] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/24/2020] [Revised: 07/08/2020] [Accepted: 08/10/2020] [Indexed: 12/11/2022]
Abstract
When performing contrast-enhanced ultrasound (CEUS), ultrasound (US) scanner settings, examination technique, and contrast agent dose and administration must be optimized to ensure that high-quality, diagnostic and reproducible images are acquired for qualitative and quantitative interpretations. When carrying out CEUS in children, examination settings should be tailored to their body size and specific indications, similar to B-mode US. This review article details the basic background knowledge that is needed to perform CEUS optimally in children, including considerations related to US scanner settings and US contrast agent dose selection and administration techniques.
Collapse
Affiliation(s)
- Misun Hwang
- Department of Radiology, Children's Hospital of Philadelphia, 3401 Civic Center Blvd., Philadelphia, PA, 19104, USA. .,Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA.
| | - Susan J Back
- Department of Radiology, Children's Hospital of Philadelphia, 3401 Civic Center Blvd., Philadelphia, PA, 19104, USA.,Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - Ryne A Didier
- Department of Radiology, Children's Hospital of Philadelphia, 3401 Civic Center Blvd., Philadelphia, PA, 19104, USA.,Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - Norbert Lorenz
- Children's Hospital, Dresden Municipal Hospital, Teaching-Hospital of Technical University, Dresden, Germany
| | - Trudy A Morgan
- Department of Radiology, Children's Hospital of Philadelphia, 3401 Civic Center Blvd., Philadelphia, PA, 19104, USA
| | - Laura Poznick
- Department of Radiology, Children's Hospital of Philadelphia, 3401 Civic Center Blvd., Philadelphia, PA, 19104, USA
| | - Ludwig Steffgen
- Trainings-Zentrum Ultraschall-Diagnostik LS GmbH, Mainleus, Germany
| | - Anush Sridharan
- Department of Radiology, Children's Hospital of Philadelphia, 3401 Civic Center Blvd., Philadelphia, PA, 19104, USA
| |
Collapse
|
4
|
Paltiel HJ, Barth RA, Bruno C, Chen AE, Deganello A, Harkanyi Z, Henry MK, Ključevšek D, Back SJ. Contrast-enhanced ultrasound of blunt abdominal trauma in children. Pediatr Radiol 2021; 51:2253-2269. [PMID: 33978795 DOI: 10.1007/s00247-020-04869-w] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/26/2020] [Revised: 08/26/2020] [Accepted: 09/30/2020] [Indexed: 12/13/2022]
Abstract
Trauma is the leading cause of morbidity and mortality in children, and rapid identification of organ injury is essential for successful treatment. Contrast-enhanced ultrasound (CEUS) is an appealing alternative to contrast-enhanced CT in the evaluation of children with blunt abdominal trauma, mainly with respect to the potential reduction of population-level exposure to ionizing radiation. This is particularly important in children, who are more vulnerable to the hazards of ionizing radiation than adults. CEUS is useful in hemodynamically stable children with isolated blunt low- to moderate-energy abdominal trauma to rule out solid organ injuries. It can also be used to further evaluate uncertain contrast-enhanced CT findings, as well as in the follow-up of conservatively managed traumatic injuries. CEUS can be used to detect abnormalities that are not apparent by conventional US, including infarcts, pseudoaneurysms and active bleeding. In this article we present the current experience from the use of CEUS for the evaluation of pediatric blunt abdominal trauma, emphasizing the examination technique and interpretation of major abnormalities associated with injuries in the liver, spleen, kidneys, adrenal glands, pancreas and testes. We also discuss the limitations of the technique and offer a review of the major literature on this topic in children, including an extrapolation of experience from adults.
Collapse
Affiliation(s)
- Harriet J Paltiel
- Department of Radiology, Boston Children's Hospital, Harvard Medical School, 300 Longwood Ave., Boston, MA, 02115, USA.
| | - Richard A Barth
- Department of Radiology, Lucile Packard Children's Hospital at Stanford, Stanford University School of Medicine, Stanford, CA, USA
| | - Costanza Bruno
- Department of Radiology, Azienda Ospedaliera Universitaria Integrata, University of Verona, Verona, Italy
| | - Aaron E Chen
- Department of Pediatrics, Division of Emergency Medicine, Children's Hospital of Philadelphia, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | | | - Zoltan Harkanyi
- Department of Radiology, Heim Pal National Pediatric Institute, Budapest, Hungary
| | - M Katherine Henry
- Safe Place: The Center for Child Protection and Health, Division of General Pediatrics, Children's Hospital of Philadelphia, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
- Department of Radiology, Children's Hospital of Philadelphia, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - Damjana Ključevšek
- Department of Radiology, University Children's Hospital Ljubljana, Ljubljana, Slovenia
| | - Susan J Back
- Department of Radiology, Children's Hospital of Philadelphia, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| |
Collapse
|
5
|
Patil PG, Reddy P, Rawat S, Ananthasivan R, Sinha R. Multimodality Approach in Detection and Characterization of Hepatic Metastases. JOURNAL OF GASTROINTESTINAL AND ABDOMINAL RADIOLOGY 2020. [DOI: 10.1055/s-0039-3402100] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
AbstractEarly detection of liver metastases is important in patients with known primary malignancies. This plays an important role in treatment planning and impacts on further management of certain primary malignancies.Magnetic resonance imaging (MRI), computed tomography (CT), and positron emission tomography-computed tomography scans are reported to have high accuracy in the diagnosis of intrahepatic lesions. MRI in particular has the advantages of its high tissue sensitivity and its multiparametric approach.Hepatic metastatic lesions have considerable overlap in their radiological appearance, and in this article the imaging appearance of various hepatic metastasis and approach is described.
Collapse
Affiliation(s)
- Pooja G. Patil
- Department of Radiology, Manipal Hospital, Bangalore, Karnataka, India
| | - Pramesh Reddy
- Department of Radiology, Manipal Hospital, Bangalore, Karnataka, India
| | - Sudarshan Rawat
- Department of Radiology, Manipal Hospital, Bangalore, Karnataka, India
| | - Rupa Ananthasivan
- Department of Radiology, Manipal Hospital, Bangalore, Karnataka, India
| | - Rakesh Sinha
- Department of Radiology, South Warwickshire NHS Foundation Trust, Warwick, United Kingdom
| |
Collapse
|
6
|
Liu X, Jang HJ, Khalili K, Kim TK, Atri M. Successful Integration of Contrast-enhanced US into Routine Abdominal Imaging. Radiographics 2018; 38:1454-1477. [DOI: 10.1148/rg.2018170152] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Affiliation(s)
- Xiaoyang Liu
- From the Department of Medical Imaging, University of Toronto, University Health Network, Toronto General Hospital, 585 University Ave, Toronto, ON, Canada M5G 2N2
| | - Hyun-Jung Jang
- From the Department of Medical Imaging, University of Toronto, University Health Network, Toronto General Hospital, 585 University Ave, Toronto, ON, Canada M5G 2N2
| | - Korosh Khalili
- From the Department of Medical Imaging, University of Toronto, University Health Network, Toronto General Hospital, 585 University Ave, Toronto, ON, Canada M5G 2N2
| | - Tae Kyoung Kim
- From the Department of Medical Imaging, University of Toronto, University Health Network, Toronto General Hospital, 585 University Ave, Toronto, ON, Canada M5G 2N2
| | - Mostafa Atri
- From the Department of Medical Imaging, University of Toronto, University Health Network, Toronto General Hospital, 585 University Ave, Toronto, ON, Canada M5G 2N2
| |
Collapse
|
7
|
Kaur H, Hindman NM, Al-Refaie WB, Arif-Tiwari H, Cash BD, Chernyak V, Farrell J, Grajo JR, Horowitz JM, McNamara MM, Noto RB, Qayyum A, Lalani T, Kamel IR. ACR Appropriateness Criteria ® Suspected Liver Metastases. J Am Coll Radiol 2018; 14:S314-S325. [PMID: 28473088 DOI: 10.1016/j.jacr.2017.01.037] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2017] [Revised: 01/19/2017] [Accepted: 01/23/2017] [Indexed: 12/20/2022]
Abstract
Liver metastases are the most common malignant liver tumors. The accurate and early detection and characterization of liver lesions is the key to successful treatment strategies. Increasingly, surgical resection in combination with chemotherapy is effective in significantly improving survival if all metastases are successfully resected. MRI and multiphase CT are the primary imaging modalities in the assessment of liver metastasis, with the relative preference toward multiphase CT or MRI depending upon the clinical setting (ie, surveillance or presurgical planning). The optimization of imaging parameters is a vital factor in the success of either modality. PET/CT, intraoperative ultrasound are used to supplement CT and MRI. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer-reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment.
Collapse
Affiliation(s)
| | - Harmeet Kaur
- Principal Author, University of Texas, MD Anderson Cancer Center, Houston, Texas.
| | - Nicole M Hindman
- Co-author, New York University Medical Center, New York, New York
| | - Waddah B Al-Refaie
- Georgetown University Hospital, Washington, District of Columbia; American College of Surgeons
| | - Hina Arif-Tiwari
- University of Arizona, Banner University Medical Center, Tucson, Arizona
| | - Brooks D Cash
- University of South Alabama, Mobile, Alabama; American Gastroenterological Association
| | | | - James Farrell
- Interventional Endoscopy and Pancreatic Diseases, New Haven, Connecticut; American Gastroenterological Association
| | - Joseph R Grajo
- University of Florida College of Medicine, Gainesville, Florida
| | | | | | - Richard B Noto
- Brown University Rhode Island Hospital, Providence, Rhode Island
| | - Aliya Qayyum
- University of Texas, MD Anderson Cancer Center, Houston, Texas
| | - Tasneem Lalani
- Specialty Chair, Inland Imaging Associates and University of Washington, Seattle, Washington
| | - Ihab R Kamel
- Panel Chair, Johns Hopkins University School of Medicine, Baltimore, Maryland
| |
Collapse
|
8
|
Anupindi SA, Biko DM, Ntoulia A, Poznick L, Morgan TA, Darge K, Back SJ. Contrast-enhanced US Assessment of Focal Liver Lesions in Children. Radiographics 2017; 37:1632-1647. [DOI: 10.1148/rg.2017170073] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Affiliation(s)
- Sudha A. Anupindi
- From the Department of Radiology, The Children’s Hospital of Philadelphia, University of Pennsylvania, Perelman School of Medicine, 3401 Civic Center Blvd, Philadelphia, PA 19104
| | - David M. Biko
- From the Department of Radiology, The Children’s Hospital of Philadelphia, University of Pennsylvania, Perelman School of Medicine, 3401 Civic Center Blvd, Philadelphia, PA 19104
| | - Aikaterini Ntoulia
- From the Department of Radiology, The Children’s Hospital of Philadelphia, University of Pennsylvania, Perelman School of Medicine, 3401 Civic Center Blvd, Philadelphia, PA 19104
| | - Laura Poznick
- From the Department of Radiology, The Children’s Hospital of Philadelphia, University of Pennsylvania, Perelman School of Medicine, 3401 Civic Center Blvd, Philadelphia, PA 19104
| | - Trudy A. Morgan
- From the Department of Radiology, The Children’s Hospital of Philadelphia, University of Pennsylvania, Perelman School of Medicine, 3401 Civic Center Blvd, Philadelphia, PA 19104
| | - Kassa Darge
- From the Department of Radiology, The Children’s Hospital of Philadelphia, University of Pennsylvania, Perelman School of Medicine, 3401 Civic Center Blvd, Philadelphia, PA 19104
| | - Susan J. Back
- From the Department of Radiology, The Children’s Hospital of Philadelphia, University of Pennsylvania, Perelman School of Medicine, 3401 Civic Center Blvd, Philadelphia, PA 19104
| |
Collapse
|
9
|
Bakas S, Makris D, Hunter GJA, Fang C, Sidhu PS, Chatzimichail K. Automatic Identification of the Optimal Reference Frame for Segmentation and Quantification of Focal Liver Lesions in Contrast-Enhanced Ultrasound. ULTRASOUND IN MEDICINE & BIOLOGY 2017; 43:2438-2451. [PMID: 28705557 DOI: 10.1016/j.ultrasmedbio.2017.06.005] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/28/2017] [Revised: 05/17/2017] [Accepted: 06/02/2017] [Indexed: 06/07/2023]
Abstract
Post-examination interpretation of contrast-enhanced ultrasound (CEUS) cineloops of focal liver lesions (FLLs) requires offline manual assessment by experienced radiologists, which is time-consuming and generates subjective results. Such assessment usually starts by manually identifying a reference frame, where FLL and healthy parenchyma are well-distinguished. This study proposes an automatic computational method to objectively identify the optimal reference frame for distinguishing and hence delineating an FLL, by statistically analyzing the temporal intensity variation across the spatially discretized ultrasonographic image. Level of confidence and clinical value of the proposed method were quantitatively evaluated on retrospective multi-institutional data (n = 64) and compared with expert interpretations. Results support the proposed method for facilitating easier, quicker and reproducible assessment of FLLs, further increasing the radiologists' confidence in diagnostic decisions. Finally, our method yields a useful training tool for radiologists, widening CEUS use in non-specialist centers, potentially leading to reduced turnaround times and lower patient anxiety and healthcare costs.
Collapse
Affiliation(s)
- Spyridon Bakas
- Digital Information Research Centre (DIRC), School of Computer Science & Mathematics, Faculty of Science, Engineering and Computing (SEC), Kingston University, Penrhyn Road, Kingston-Upon-Thames, London, United Kingdom; Center for Biomedical Image Computing and Analytics (CBICA), Perelman School of Medicine, University of Pennsylvania, Richards Medical Research Laboratories, Philadelphia, PA, USA.
| | - Dimitrios Makris
- Digital Information Research Centre (DIRC), School of Computer Science & Mathematics, Faculty of Science, Engineering and Computing (SEC), Kingston University, Penrhyn Road, Kingston-Upon-Thames, London, United Kingdom
| | - Gordon J A Hunter
- Digital Information Research Centre (DIRC), School of Computer Science & Mathematics, Faculty of Science, Engineering and Computing (SEC), Kingston University, Penrhyn Road, Kingston-Upon-Thames, London, United Kingdom
| | - Cheng Fang
- Department of Radiology, King's College Hospital, London, United Kingdom
| | - Paul S Sidhu
- Department of Radiology, King's College Hospital, London, United Kingdom
| | - Katerina Chatzimichail
- Radiology & Imaging Research Centre, Evgenidion Hospital, National and Kapodistrian University, Athens, Greece
| |
Collapse
|
10
|
Barr RG. How to Develop a Contrast-Enhanced Ultrasound Program. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2017; 36:1225-1240. [PMID: 28151552 DOI: 10.7863/ultra.16.09045] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/22/2016] [Accepted: 11/08/2016] [Indexed: 06/06/2023]
Abstract
With the recent Food and Drug Administration approval of Lumason (sulfur hexafluoride lipid-type A microsphere, Bracco Diagnostics Inc, Monroe Township, NJ) for contrast-enhanced ultrasound (CEUS) to characterize focal liver lesions in both adult and pediatric patients, widespread use of CEUS is expected in the United States. This paper provides guidance in setting up a CEUS program, and reviews the practical details that will need to be instituted in a standard ultrasound department to provide both safe and efficient use of CEUS. A review of the indications, contraindications, adverse events, instructions for performing the exam, and image interpretation are discussed.
Collapse
Affiliation(s)
- Richard G Barr
- Northeast Ohio Medical University, Rootstown, Ohio USA
- Radiology Consultants, Youngstown, Ohio, USA
| |
Collapse
|
11
|
Jo PC, Jang HJ, Burns PN, Burak KW, Kim TK, Wilson SR. Integration of Contrast-enhanced US into a Multimodality Approach to Imaging of Nodules in a Cirrhotic Liver: How I Do It. Radiology 2017; 282:317-331. [PMID: 28099108 DOI: 10.1148/radiol.2016151732] [Citation(s) in RCA: 63] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Accurate characterization of cirrhotic nodules and early diagnosis of hepatocellular carcinoma (HCC) are of vital importance. Currently, computed tomography (CT) and magnetic resonance (MR) imaging are standard modalities for the investigation of new nodules found at surveillance ultrasonography (US). This article describes the successful integration of contrast material-enhanced US into a multimodality approach for diagnosis of HCC and its benefits in this population. The application of contrast-enhanced US immediately following surveillance US allows for prompt dynamic contrast-enhanced evaluation, removing the need for further imaging of benign lesions. Contrast-enhanced US also provides dynamic real-time assessment of tumor vascularity so that contrast enhancement can be identified regardless of its timing or duration, allowing for detection of arterial hypervascularity and portal venous washout. The purely intravascular nature of US contrast agents is valuable as the rapid washout of nonhepatocyte malignancies is highly contributory to their differentiation from HCC. The authors believe contrast-enhanced US provides complementary information to CT and MR imaging in the characterization of nodules in high-risk patients. © RSNA, 2017 Online supplemental material is available for this article.
Collapse
Affiliation(s)
- Patricia C Jo
- From the Department of Radiology (P.C.J., S.R.W.) and Department of Medicine, Division of Gastroenterology (K.W.B., S.R.W.), Foothills Medical Centre, University of Calgary, 1403 29 St NW, Calgary, AB, Canada T2N 2T9; Department of Medical Imaging, Toronto General Hospital, University of Toronto, Toronto, Ont, Canada (H.J.J., T.K.K.); and Department of Imaging Research, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ont, Canada (P.N.B.)
| | - Hyun-Jung Jang
- From the Department of Radiology (P.C.J., S.R.W.) and Department of Medicine, Division of Gastroenterology (K.W.B., S.R.W.), Foothills Medical Centre, University of Calgary, 1403 29 St NW, Calgary, AB, Canada T2N 2T9; Department of Medical Imaging, Toronto General Hospital, University of Toronto, Toronto, Ont, Canada (H.J.J., T.K.K.); and Department of Imaging Research, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ont, Canada (P.N.B.)
| | - Peter N Burns
- From the Department of Radiology (P.C.J., S.R.W.) and Department of Medicine, Division of Gastroenterology (K.W.B., S.R.W.), Foothills Medical Centre, University of Calgary, 1403 29 St NW, Calgary, AB, Canada T2N 2T9; Department of Medical Imaging, Toronto General Hospital, University of Toronto, Toronto, Ont, Canada (H.J.J., T.K.K.); and Department of Imaging Research, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ont, Canada (P.N.B.)
| | - Kelly W Burak
- From the Department of Radiology (P.C.J., S.R.W.) and Department of Medicine, Division of Gastroenterology (K.W.B., S.R.W.), Foothills Medical Centre, University of Calgary, 1403 29 St NW, Calgary, AB, Canada T2N 2T9; Department of Medical Imaging, Toronto General Hospital, University of Toronto, Toronto, Ont, Canada (H.J.J., T.K.K.); and Department of Imaging Research, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ont, Canada (P.N.B.)
| | - Tae Kyoung Kim
- From the Department of Radiology (P.C.J., S.R.W.) and Department of Medicine, Division of Gastroenterology (K.W.B., S.R.W.), Foothills Medical Centre, University of Calgary, 1403 29 St NW, Calgary, AB, Canada T2N 2T9; Department of Medical Imaging, Toronto General Hospital, University of Toronto, Toronto, Ont, Canada (H.J.J., T.K.K.); and Department of Imaging Research, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ont, Canada (P.N.B.)
| | - Stephanie R Wilson
- From the Department of Radiology (P.C.J., S.R.W.) and Department of Medicine, Division of Gastroenterology (K.W.B., S.R.W.), Foothills Medical Centre, University of Calgary, 1403 29 St NW, Calgary, AB, Canada T2N 2T9; Department of Medical Imaging, Toronto General Hospital, University of Toronto, Toronto, Ont, Canada (H.J.J., T.K.K.); and Department of Imaging Research, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ont, Canada (P.N.B.)
| |
Collapse
|
12
|
Catalano O, Sandomenico F, Vallone P, Setola SV, Granata V, Fusco R, Lastoria S, Mansi L, Petrillo A. Contrast-Enhanced Ultrasound in the Assessment of Patients with Indeterminate Abdominal Findings at Positron Emission Tomography Imaging. ULTRASOUND IN MEDICINE & BIOLOGY 2016; 42:2717-2723. [PMID: 27495384 DOI: 10.1016/j.ultrasmedbio.2016.06.023] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/04/2016] [Revised: 06/01/2016] [Accepted: 06/08/2016] [Indexed: 06/06/2023]
Abstract
Widespread use of fluorodeoxyglucose-positron emission tomography (PET) in cancer imaging may result in a number of indeterminate and false-positive findings. We investigated the role of contrast-enhanced ultrasound (CEUS) as a second-level option after inconclusive PET. We reviewed CEUS images acquired over 4 y, selecting the examinations performed specifically to better assess an unclear PET image. Final diagnosis was confirmed by biopsy, surgery, further imaging or follow-up. Seventy CEUS examinations were performed after a PET scan (44 PET examinations, 19 PET-computer tomography [CT] examinations and 7 PET-CECT examinations). The target organ was the liver in 54 cases, spleen in 12, gallbladder in 2 and pancreas and kidney in one each. In 6 of 70 cases, CEUS was performed because of a negative PET (no uptake) despite an abnormal finding on the CT images of the PET-CT study; CEUS allowed a correct diagnosis in all of these. In 20 of 70 cases, the PET findings were categorized as indeterminate and non-specific (non-specific fluorodeoxyglucose uptake in PET report with no standardized uptake value given); CEUS reached a correct diagnosis in 19 of the 20 cases with one false negative. In 34 of 70 cases, PET was indeterminate, but specific (fluorodeoxyglucose uptake with a standardized uptake value provided); CEUS reached a correct diagnosis in 30 of these 34 cases. In 10 of 70 cases, PET was categorized as determinate but to be investigated because of discrepancy with clinical or imaging findings; CEUS a definitive diagnosis in 9 of 10 cases. CEUS proved to be effective option in the assessment of cancer patients with indeterminate PET findings.
Collapse
Affiliation(s)
- Orlando Catalano
- Department of Radiology, National Cancer Institute, Fondazione Pascale, Naples, Italy.
| | - Fabio Sandomenico
- Department of Radiology, National Cancer Institute, Fondazione Pascale, Naples, Italy
| | - Paolo Vallone
- Department of Radiology, National Cancer Institute, Fondazione Pascale, Naples, Italy
| | | | - Vincenza Granata
- Department of Radiology, National Cancer Institute, Fondazione Pascale, Naples, Italy
| | - Roberta Fusco
- Department of Radiology, National Cancer Institute, Fondazione Pascale, Naples, Italy
| | - Secondo Lastoria
- Department of Nuclear Medicine, National Cancer Institute, Fondazione Pascale, Naples, Italy
| | - Luigi Mansi
- Department of Nuclear Medicine, Second University of Naples, Naples, Italy
| | - Antonella Petrillo
- Department of Radiology, National Cancer Institute, Fondazione Pascale, Naples, Italy
| |
Collapse
|
13
|
Rosado E, Riccabona M. Off-Label Use of Ultrasound Contrast Agents for Intravenous Applications in Children: Analysis of the Existing Literature. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2016; 35:487-496. [PMID: 26839372 DOI: 10.7863/ultra.15.02030] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/19/2015] [Accepted: 06/20/2015] [Indexed: 06/05/2023]
Abstract
OBJECTIVES The purpose of this study was to collect and analyze the published data related to intravenous (IV) use of ultrasound (US) contrast agents in children. METHODS We searched the literature to collect all of the published studies reporting the IV administration of a second-generation US contrast agent in children. RESULTS We analyzed 9 case series and 5 case reports, as well as 5 individual cases, of pediatric contrast-enhanced US use reported in a study group that also included adults. We found that 502 children underwent contrast-enhanced US examinations (mean age, 9.7 years; range, 1 day-18 years). Most patients (89%) were injected with the sulfur hexafluoride contrast agent SonoVue (Bracco SpA, Milan, Italy). The mean dose used was 1.5 mL (range, 0.1-9.6 mL). Only 10 patients (2%) had adverse reactions related to the contrast agent administration: 1 life-threatening anaphylactic shock and 9 mild transitory adverse effects. We additionally found 38 papers in which the study groups included at least 1 child; thus, we obtained a total of 540 reported cases of off-label use of IV US contrast agents in children. The most frequent target organ was the liver, and most indications were related to space-occupying lesion characterization and abdominal evaluations after blunt trauma. Some studies also evaluated the diagnostic performance of contrast-enhanced US in different clinical scenarios and found very good accuracy. Concordance between contrast-enhanced US imaging and the respective reference-standard imaging methods ranged between 83% and 100% in different studies. CONCLUSIONS Our results support the idea that the IV use of US contrast agents in children is safe, feasible, diagnostically robust, and effective.
Collapse
Affiliation(s)
- Elsa Rosado
- Department of Radiology, Hospital Prof Doutor Fernando Fonseca, Amadora, Portugal (E.R.); Department of Radiology, Division of Pediatric Radiology, Universitätsklinikum LKH, Graz, Austria (M.R.).
| | - Michael Riccabona
- Department of Radiology, Hospital Prof Doutor Fernando Fonseca, Amadora, Portugal (E.R.); Department of Radiology, Division of Pediatric Radiology, Universitätsklinikum LKH, Graz, Austria (M.R.)
| |
Collapse
|
14
|
D'Onofrio M, Romanini L, Serra C, Magnolfi F, Bertolotto M, Quaia E, Puntel G, Colleoni A, Fiorini E, Cenci C, Santi E, Ciaravino V, Laffranchi F, Catalano O, Cantisani V, Calliada F, Derchi L. Contrast enhancement ultrasound application in focal liver lesions characterization: a retrospective study about guidelines application (SOCEUS-CEUS survey). J Ultrasound 2015; 19:99-106. [PMID: 27298641 DOI: 10.1007/s40477-015-0185-y] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2015] [Accepted: 09/02/2015] [Indexed: 02/07/2023] Open
Abstract
INTRODUCTION The SOCEUS survey aims to evaluate how contrast-enhanced ultrasound (CEUS) is effectively used in the focal liver lesions characterization. MATERIALS AND METHODS In the survey were involved Verona, Brescia and Trieste Radiological Centers and Arezzo and Bologna Non-radiological Centers. Inclusion criteria were liver focal lesion detection at conventional ultrasound and studied by means of CEUS, with or without CT or MRI examinations, done previous or subsequent to CEUS. RESULTS 1069 forms were collected. Patients with benign lesions, who did not undergo any other studies, were 255/561 (45.5 %). Among patients with diagnosis of hemangioma at CEUS, those who had no other investigations were 129/267 (48.3 %). Patients with malignant lesions who had studies pre-CEUS (CT and/or MRI) were 328/508 (65 %), whereas those who had examinations post-CEUS (CT and/or MRI) were 218/508 (42.9 %). Concordance rate between CEUS and CT investigations pre- and post-CEUS was, respectively, 66 and 89 %. Concordance rate between CEUS and MRI studies pre- and post-CEUS was, respectively, 87.5 and 81.5 %. CONCLUSION This study proves contrast-enhanced ultrasound correct application in the involved centers.
Collapse
Affiliation(s)
- Mirko D'Onofrio
- Department of Radiology, University Hospital G.B. Rossi, University of Verona Piazzale L. A. Scuro 10, 37134 Verona, Italy
| | - Laura Romanini
- Department of Radiology, University of Brescia, Spedali Civili, Brescia, Italy
| | - Carla Serra
- Department of organ failure and transplantation, University Hospital S. Orsola, Bologna, Italy
| | | | - Michele Bertolotto
- Department of Radiology, University of Trieste, Cattinara Hospital, Trieste, Italy
| | - Emilio Quaia
- Department of Radiology, University of Trieste, Cattinara Hospital, Trieste, Italy
| | - Gino Puntel
- Department of Radiology, University Hospital G.B. Rossi, University of Verona Piazzale L. A. Scuro 10, 37134 Verona, Italy
| | - Alessandro Colleoni
- Department of Radiology, University of Brescia, Spedali Civili, Brescia, Italy
| | - Erica Fiorini
- Department of organ failure and transplantation, University Hospital S. Orsola, Bologna, Italy
| | - Cristina Cenci
- Department of Gastroenterology, S. Donato Hospital, Arezzo, Italy
| | - Elena Santi
- Department of Radiology, University Hospital G.B. Rossi, University of Verona Piazzale L. A. Scuro 10, 37134 Verona, Italy
| | - Valentina Ciaravino
- Department of Radiology, University Hospital G.B. Rossi, University of Verona Piazzale L. A. Scuro 10, 37134 Verona, Italy
| | | | - Orlando Catalano
- Department of Radiology, Istituto Nazionale Tumori Fondazione Pascale, Naples, Italy
| | - Vito Cantisani
- Department of Radiology, Policlinico Umberto I, University La Sapienza, Rome, Italy
| | - Fabrizio Calliada
- Department of Radiology, University Hospital S. Matteo, Pavia, Italy
| | - Lorenzo Derchi
- Department of Health Sciences (DISSAL, University of Genoa), IRCCS AOU San Martino IST, Genoa, Italy
| |
Collapse
|
15
|
Jang HJ, Kim TK, Burns PN, Wilson SR. CEUS: An essential component in a multimodality approach to small nodules in patients at high-risk for hepatocellular carcinoma. Eur J Radiol 2015; 84:1623-35. [DOI: 10.1016/j.ejrad.2015.05.020] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2015] [Accepted: 05/11/2015] [Indexed: 02/07/2023]
|
16
|
Joshi P, George RA, Tyagi AK, Sinha A. Efficacy of contrast enhanced grey scale ultrasound in characterisation of hepatic focal lesions: A pilot study. Med J Armed Forces India 2014; 70:230-6. [PMID: 25378775 DOI: 10.1016/j.mjafi.2014.05.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2013] [Accepted: 05/25/2014] [Indexed: 11/29/2022] Open
Abstract
BACKGROUND Contrast enhanced ultrasound (CEUS) has recently gained widespread acceptance as an adjunct to conventional grey scale ultrasound. The present pilot study was undertaken to evaluate the efficacy of this technique in characterisation of hepatic focal lesions. METHODS Adult patients who had at least one focal liver lesion underwent ultrasound evaluation in regular and contrast mode before and after intravenous administration of sulphur hexafluoride. The diagnoses were confirmed by comparison with a reference standard (multidetector CT), response to treatment or pathological correlation. RESULTS The rate of correct diagnosis for unenhanced ultrasound was 54%, CEUS was 72% and multidetector CT (MDCT) was 92%. A comparison of unenhanced ultrasound versus CEUS using the McNemar test yielded a p value of 0.0704 (>0.05). However, comparison of CEUS versus MDCT using the McNemar test yielded a p value of 0.0265 (<0.05). Additionally, comparison of unenhanced ultrasound versus MDCT using the McNemar test yielded a p value of <0.0001. CONCLUSION CEUS increases diagnostic efficacy over unenhanced ultrasound but does not have any significant advantages over MDCT. Currently it may be used as a problem solving tool in atypical haemangiomas, echogenic focal liver lesions, contrast sensitivity and to avoid multiple studies utilising ionising radiation.
Collapse
Affiliation(s)
- P Joshi
- Classified Specialist (Radiodiagnosis), INHS Asvini, Colaba, Mumbai 400005, India
| | - R A George
- Senior Advisor (Radiodiagnosis), Command Hospital (Air Force), Bangalore 560007, India
| | - A K Tyagi
- Senior Advisor (Surgery and Surgical Oncology), Army Hospital (R&R), Delhi Cantt, India
| | - Anamika Sinha
- Classified Specialist (Pathology), Command Hospital (Northern Command), C/o 56 APO, India
| |
Collapse
|
17
|
Abstract
Hepatocellular carcinoma (HCC) is the most common primary hepatic malignancy, and usually develops in the setting of liver cirrhosis. The early diagnosis of HCC is essential as curative treatment (including surgical resection and liver transplantation) improves survival. While screening and surveillance are traditionally performed with ultrasound, reported accuracies of ultrasound vary greatly, and poor sensitivity for small nodules is a uniformly recognized concern. Advances in computed tomography (CT) and magnetic resonance imaging (MRI), including multidetector technology and fast breath hold sequences now allow dynamic multiphasic enhanced imaging of the liver with excellent spatial and temporal resolution, holding much promise for improved HCC detection.
Collapse
|
18
|
Lee J, Karshafian R, Papanicolau N, Giles A, Kolios MC, Czarnota GJ. Quantitative ultrasound for the monitoring of novel microbubble and ultrasound radiosensitization. ULTRASOUND IN MEDICINE & BIOLOGY 2012; 38:1212-1221. [PMID: 22579547 DOI: 10.1016/j.ultrasmedbio.2012.01.028] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/08/2011] [Revised: 01/23/2012] [Accepted: 01/27/2012] [Indexed: 05/31/2023]
Abstract
There is a need for cancer imaging to provide "real-time" information about the metabolic and cellular responses of tumours. Quantitative ultrasound techniques have recently been demonstrated to be a potential method of assessing tumour response at the cellular level. Anti-cancer treatments administered to xenograft-bearing mice consisted of radiotherapy and a novel antivascular therapy utilizing encapsulated microbubble agents in the presence of ultrasound. Radiation dose and microbubble concentrations were varied and the treatment modalities were given in combination to assess the possible enhancement of tumour cell death. Quantitative methods were used to non-invasively assess responses. Results demonstrated statistically significant changes in backscatter parameters (midband fit, spectral intercept) in tumours treated with high doses of radiotherapy or a high concentration of microbubbles. Combined treatments demonstrated further increases in ultrasound parameters. Histopathologic assessment was used and tumour cell death was found to correlate with increases in ultrasound parameters.
Collapse
Affiliation(s)
- Justin Lee
- Department of Radiation Oncology, Odette Cancer Centre, Sunnybrook Health Sciences Centre, and University of Toronto, Toronto, Ontario, Canada
| | | | | | | | | | | |
Collapse
|
19
|
Abstract
In patients with known malignant disease, 51% of liver lesions less than 1.5 cm turn out to be benign. Whether the probability of malignancy is high or low, further investigations are often necessary to definitely exclude malignancy. Contrast-enhanced ultrasonography has a prominent role in lesion characterization with a diagnostic accuracy comparable with computed tomography and magnetic resonance imaging. Anti-angiogenic treatment is common in most oncological institutions and the response evaluation is a new challenge with a research focus on the change in tumour vasculature and perfusion. In planning biopsies, CEUS can identify necrotic and viable areas of tumours and improve the diagnostic accuracy.
Collapse
Affiliation(s)
- H H T Madsen
- Department of Radiology, Aarhus University Hospital, Aarhus, Denmark.
| | | |
Collapse
|
20
|
Low G, Winters SD, Owen RJT. Surveillance of a coiled renal artery aneurysm by contrast-enhanced ultrasound with Definity. J Vasc Surg 2011; 54:1801-4. [PMID: 21890309 DOI: 10.1016/j.jvs.2011.06.077] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2011] [Revised: 06/20/2011] [Accepted: 06/20/2011] [Indexed: 10/17/2022]
Abstract
Imaging surveillance is necessary to assess for long-term procedural outcomes after endovascular treatment. This is generally performed by computed tomography (CT) or magnetic resonance imaging (MRI). Contrast-enhanced ultrasound (CEUS) has recognized utility for cardiovascular and abdominal applications and is an alternative option in patients with renal impairment or CT/MR contrast-related reactions. We believe that we present the first reported case of CEUS in the surveillance of a treated renal artery aneurysm. The 57-year-old patient had a severe CT contrast allergy. CEUS performed with Definity microbubble ultrasound contrast (Lantheus Medical Imaging, Billerica, Mass) was well tolerated and showed no residual filling of the aneurysm.
Collapse
Affiliation(s)
- Gavin Low
- Department of Radiology and Diagnostic Imaging, University of Alberta Hospital, Edmonton, Alberta, Canada.
| | | | | |
Collapse
|
21
|
Schmillevitch J, Szutan LA, Ferreira FG, Santos MDF, Mincis R, Gorski A. Prospective study of ultrasound with perflutrene contrast compared to magnetic resonance imaging in the diagnosis of hepatic hemangiomas. ARQUIVOS DE GASTROENTEROLOGIA 2011; 48:119-23. [PMID: 21709953 DOI: 10.1590/s0004-28032011000200007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/22/2010] [Accepted: 11/19/2010] [Indexed: 11/22/2022]
Abstract
CONTEXT The incidence of hepatic hemangiomas ranges from 0.4% to 20% in the general population. Conventional ultrasound is usually the first diagnostic method to identify these hemangiomas, typically as an incidental finding. Ultrasonography with second generation contrast materials is being used in various areas of hepatology, yielding similar results to those obtained with computerized tomography and magnetic resonance imaging in the diagnosis of hepatic hemangiomas. OBJECTIVE To evaluate the agreement between ultrasound with perflutrene contrast and magnetic resonance imaging in the diagnosis of hepatic hemangiomas. METHODS A total of 37 patients were prospectively examined between January 2006 and August 2008. A total of 57 hepatic nodules were documented in this group as incidental findings on routine ultrasound exams. The 37 patients were administered perflutrene contrast without adverse reactions, and were all submitted to magnetic resonance exams. RESULTS Conventional ultrasound identified 15 patients with nodules typical of hemangiomas and 22 patients with other nodules. In 35 patients, the contrast characteristics were consistent with hepatic hemangiomas. CONCLUSION Agreement between the data obtained from ultrasound with contrast and magnetic resonance was 94.5%. In discordant cases, the magnetic resonance diagnosis prevailed. In the case which presented indeterminate findings on contrast ultrasonography, magnetic resonance was repeated after 3 months, confirming the diagnosis of a hepatic hemangioma. A biopsy was performed on the suspected malignant nodule which also confirmed the presence of a hepatic hemangioma. Ultrasonography with contrast has the advantages of being more accessible to the public at large and lower cost than magnetic resonance. The results of our study highlight the need for a new protocol in hepatic nodules incidentally identified on conventional ultrasonography. In the case of typical hemangiomas, conventional ultrasound is sufficient for diagnosis. However, for poorly defined nodules, ultrasonography with contrast is indicated. After confirming the presence of a hepatic hemangioma on contrast ultrasonography, no further exams are needed to finalize the diagnosis.
Collapse
Affiliation(s)
- Joel Schmillevitch
- Department of Surgery, Faculty of Medical Sciences, Santa Casa of São Paulo, São Paulo, SP, Brasil.
| | | | | | | | | | | |
Collapse
|
22
|
Indeterminate focal liver lesions incidentally discovered at gray-scale US: role of contrast-enhanced sonography. Invest Radiol 2011; 46:106-15. [PMID: 20938345 DOI: 10.1097/rli.0b013e3181f44184] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
OBJECTIVES to assess the role of contrast-enhanced ultrasound (CEUS) in the characterization of focal liver lesions (FLLs) incidentally discovered but indeterminate at gray-scale ultrasound (US). MATERIALS AND METHODS one hundred forty-two consecutive patients with 174 FLLs (169 benign and 5 malignant) incidentally discovered but indeterminate at gray-scale US, underwent CEUS after the administration of SonoVue. Two readers independently reviewed CEUS scans and: (1) classified each lesion as malignant or benign on a 5-point scale of confidence by means of definite diagnostic criteria; (2) provided if possible a specific diagnosis; (3) were requested if further imaging was needed for lesion characterization. Sensitivity, specificity, and areas under the receiver-operating characteristic curve (Az) as well as interobserver agreement were calculated. RESULTS at CEUS, both readers correctly differentiated benign from malignant lesions in 168 of 174 (96.5%) cases (P < 0.0001). A specific correct diagnosis was provided in 123 of 174 (70.7%) and 127 of 174 (72.9%) cases for reader 1 and 2, respectively (P < 0.0001). A further imaging study to characterize the lesion after CEUS was requested in 67 cases (38.5%) for reader 1 (P < 0.001) and 46 cases (26.4%) for reader 2 (P < 0.001). Receiver-operating characteristic analysis after CEUS revealed Az value of 1 for both readers and sensitivity and specificity values of 100% and 97.04% for reader 1 and 100% and 96.45 for reader 2 respectively (P < 0.0001). Inter-reader agreement at CEUS was good (weighted k = 0.779). CONCLUSION CEUS improves the diagnostic performance of radiologists in the characterization of indeterminate FLLs incidentally discovered at US and reduces the need for further radiologic work-up.
Collapse
|
23
|
Catalano O, Sandomenico F, Nunziata A, Vallone P, Raso MM, Setola SV, D'Errico AG. Source and clinical motivation of orders for contrast-enhanced sonography (CEUS) of the liver: A prospective single-center survey. J Ultrasound 2011; 14:66-74. [PMID: 23396265 DOI: 10.1016/j.jus.2011.04.005] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] Open
Abstract
Contrast-enhanced sonography (CEUS) has become a routine part of diagnostic imaging of the liver. Its possibilities, limitations, and indications have been defined in adequately large clinical series and in guidelines and recommendations. We prospectively evaluated physicians' orders for hepatic CEUS received in the radiology department of a large oncology center in Naples, Italy from May 2009 to April 2010. Radiologists performing the CEUS examinations filled out a form that included patient demography, source and type of patient referral, and clinical indications for the examination. During the study period, 564 patients aged 17-86 years (mean, 58 years) were referred to our department for CEUS liver studies (total: 644; 491 outpatient studies, 153 inpatient studies). This included 4 examinations that were ordered by the patient's physician but not performed by our staff. The majority of the CEUS examinations (n = 583; 90.5%) were regularly scheduled procedures ordered by clinical specialists from our center (77.3%) or other centers (11.8%); by general practitioners (on their own initiative) (0.8%); or by other figures (0.6%). The remaining 61 examinations (9.5%) were unscheduled procedures done on the initiative of a radiologist following conventional sonography (US). Fewer than half (47.8%) of the examinations were requested as first-line assessments. The others were ordered to clarify inconclusive findings generated by conventional US (30%) or by a more sophisticated imaging study (CT, MRI, PET) (16.1%) or to resolve discrepancies between CT, MRI, and/or PET findings (6%). CEUS is a relatively noninvasive, low-cost imaging study that is simple to perform and requires no particular patient preparation. This may explain its increasing use to clarify doubts raised by conventional US and other more sophisticated imaging studies.
Collapse
Affiliation(s)
- O Catalano
- Radiodiagnostic Operative Unit, The G. Pascal Foundation National Tumor Institute, Naples, Italy
| | | | | | | | | | | | | |
Collapse
|
24
|
Kim KA, Kim MJ, Choi JY, Chung YE. Development of hepatocellular carcinomas in patients with absence of tumors on a prior ultrasound examination. Eur J Radiol 2011; 81:1450-4. [PMID: 21514759 DOI: 10.1016/j.ejrad.2011.03.053] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2010] [Accepted: 03/15/2011] [Indexed: 01/04/2023]
Abstract
BACKGROUND To evaluate hepatocellular carcinoma (HCC) that developed in patients with no evidence of a tumor during a prior ultrasound (US) performed within 1 year of the diagnosis. METHODS We retrospectively analyzed data for 100 consecutive patients with liver cirrhosis who had undergone US within 1 year prior to HCC diagnosis and who showed no liver lesions on the previous US. Size and T stage of HCC were assessed as well as whether patients met surgical criteria for liver transplantation as HCC treatment [Milan or University of California at San Francisco (UCSF) criteria]. RESULTS The mean interval between the negative and diagnostic scans was 5 months, 13 days. HCC presented as a single nodule in 69 patients (size, 0.8-8.0 cm), as two or more nodules in 18 patients, and as the diffuse form of HCC in 13 patients. HCC presented as a small tumor (<3 cm) in 48 patients. T stages were: T1 in 26 patients, T2 in 45, T3 in 18, and T4 in 11. The Milan criteria were met in 79 patients. Eighty-five patients fulfilled the UCSF. CONCLUSION Patients may present with advanced HCC, even if sonographic findings were negative within 1 year prior to diagnosis.
Collapse
Affiliation(s)
- Kyung Ah Kim
- Department of Radiology, Yonsei University College of Medicine, Seodaemun-ku, Shinchon-dong 134, Seoul 120-752, Republic of Korea
| | | | | | | |
Collapse
|
25
|
Abstract
Contrast agents for ultrasonography (US) comprise microscopic bubbles of gas in an encapsulating shell. They are unique in that they interact with the imaging process, oscillating in response to a low-intensity ultrasound field and disrupting in response to a high-intensity field. New contrast-specific imaging modes allow US to show exquisite vascularity and tissue perfusion in real time and with excellent spatial resolution. In Europe, Asia, and Canada, to name only the most obvious, characterization of focal liver masses is the first and best established use of contrast-enhanced (CE) US, allowing for the noninvasive diagnosis of commonly encountered liver masses with comparable accuracy to that of computed tomography and magnetic resonance studies. CE US is a preferred modality for the difficult task of diagnosis of liver nodules detected on surveillance scans in those at risk for hepatocellular carcinoma. Newer body applications include the guidance of ablative intervention, monitoring activity of bowel inflammation in Crohn disease, characterization of kidney masses, especially cystic renal cell carcinoma, diagnosis of prostate cancer, and monitoring the response of tumors to antivascular drug therapies. Microbubble contrast agents are easy to use and robust; their use poses no risk of nephrotoxicity and requires no ionizing radiation. CE US plays a vital and expanding role that improves management and patient care.
Collapse
Affiliation(s)
- Stephanie R Wilson
- Department of Diagnostic Imaging, Foothills Medical Centre, University of Calgary, Calgary, AB, Canada.
| | | |
Collapse
|
26
|
Zhao L, Zhan Y, Rutkowski JL, Feuerstein GZ, Wang X. Correlation between 2- and 3-dimensional assessment of tumor volume and vascular density by ultrasonography in a transgenic mouse model of mammary carcinoma. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2010; 29:587-595. [PMID: 20375377 DOI: 10.7863/jum.2010.29.4.587] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
OBJECTIVE Visualization and quantification of angiogenesis are instrumental in development of antiangiogenic therapy. Although both 2-dimensional (2D) and 3-dimensional (3D) ultrasonography have been used to monitor tumor growth and vasculature development, the correlation between them has not been sufficiently investigated. We hereby investigated the 2D and 3D sonographic correlation for tumor volume and vascular density confirmed by histologic assessment in the polyoma virus middle T antigen (PyMT) mouse model of mammary carcinoma. METHODS Female PyMT mouse tumors were evaluated by ultrasonography in the 2D region of interest (ROI), 3D tumor volume, and 2D and 3D microvascular density after a bolus infusion of a nontargeted contrast-enhanced microbubble agent. Texas Red-dextran was used for quantitative histologic assessment of the tumor microvascular density. RESULTS The individual 2D tumor ROI area correlated with the 3D tumor volume throughout the 2-week period. However, the extent of the increase in the 3D volume (380%; P < .01; n = 10) was higher than that of the 2D ROI area (72%; P < .01; n = 8-11). A significant and comparable increase in vascular density accessed by both 2D (87%; P < .05; n = 8) and 3D (64%; P < .05; n = 8) imaging was documented. Vascular density obtained through 3D imaging correlated significantly with 2D measurement. These data were confirmed by Texas Red-dextran quantification of vascular density. Conclusions. This study showed a valid application of sonographically based imaging technology in tumor volume and vascular density assessment as well as their 2D and 3D correlation, of which tumor vascular density measured by 2D ultrasonography appeared to be better correlated with the 3D data. Our data indicate that ultrasonography can be applied for real-time, accurate, noninvasive imaging of the tumor volume and vascular density in preclinical models.
Collapse
Affiliation(s)
- Lei Zhao
- Discovery Translational Medicine, Wyeth Research, 500 Arcola Rd, Collegeville, PA 19426, USA.
| | | | | | | | | |
Collapse
|
27
|
Contrast-enhanced ultrasound: what is the evidence and what are the obstacles? AJR Am J Roentgenol 2009; 193:55-60. [PMID: 19542395 DOI: 10.2214/ajr.09.2553] [Citation(s) in RCA: 137] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
OBJECTIVE Although ultrasound contrast agents (UCAs) are popular and widely used in Europe and Asia, the U.S. Food and Drug Administration (FDA) has not approved a microbubble agent for radiology imaging in the United States. Herein, we discuss the evidence for and the obstacles to using UCAs for contrast-enhanced ultrasound (CEUS). CONCLUSION Despite the obstacles to the use of UCAs for CEUS including regulatory and practice patterns, the evidence indicates that radiologists and patients will be missing an effectual imaging option if we do not encourage the use of CEUS and strongly support the approval of UCAs by the FDA. The evidence outweighs the obstacles: CEUS is cost-effective; can be performed at the bedside; uses no ionizing radiation; has no nephrotoxicity; and, most importantly, can provide accurate diagnostic information comparable to CT and MRI.
Collapse
|
28
|
Ladam-Marcus V, Mac G, Job L, Piot-Veron S, Marcus C, Hoeffel C. [Contrast-enhanced ultrasound and liver imaging: review of the literature]. ACTA ACUST UNITED AC 2009; 90:93-106; quiz 107-8. [PMID: 19212278 DOI: 10.1016/s0221-0363(09)70087-3] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
The advent of second-generation microbubble ultrasound contrast agents and the development of contrast specific ultrasound techniques improved the ability of contrast enhanced ultrasound (CEUS) in detecting and characterizing focal liver lesions, opening new prospects in liver imaging. A Medline search in June 2008 identified 72 published studies that used CEUS in focal liver lesion detection, characterization, and follow-up to monitor tumor ablation procedures and antiangiogenic treatment. The purpose of this paper, based on literature review, is to describe the technical recommendations when using CEUS for liver imaging and to define the different vascular patterns of the most relevant benign and malignant lesions. Diagnostic performance of CEUS and the important clinical indications are also presented and discussed. CEUS is increasingly accepted in clinical use for diagnostic imaging and post-interventional workup liver imaging. It may replace many computed tomography and magnetic resonance imaging examinations in the near future, according to the European Federation of Societies for Ultrasound in Medicine and Biology guidelines.
Collapse
Affiliation(s)
- V Ladam-Marcus
- CHU de Reims, Hôpital Robert Debré, Pôle d'Imagerie, Service de Radiologie, 51092 Reims Cedex, France.
| | | | | | | | | | | |
Collapse
|
29
|
Tombesi P, Catellani M, Abbasciano V, Sartori S, Tassinari D. Impact of contrast-enhanced ultrasonography in a tertiary clinical practice. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2008; 27:991-992. [PMID: 18499863 DOI: 10.7863/jum.2008.27.6.991] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
|
30
|
|