1
|
Arian A, Abdullah AD, Taher HJ, Suhail Alareer H, Fotouhi M. Diagnostic Values of the Liver Imaging Reporting and Data System in the Detection and Characterization of Hepatocellular Carcinoma: A Systematic Review and Meta-Analysis. Cureus 2023; 15:e36082. [PMID: 37065286 PMCID: PMC10097431 DOI: 10.7759/cureus.36082] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2023] [Accepted: 03/10/2023] [Indexed: 03/14/2023] Open
Abstract
This review was undertaken to assess the diagnostic value of the Liver Imaging Reporting and Data System (LI-RADS) in patients with a high risk of hepatocellular carcinoma (HCC). Google Scholar, PubMed, Web of Science, Embase, PROQUEST, and Cochrane Library, as the international databases, were searched with appropriate keywords. Using the binomial distribution formula, the variance of all studies was calculated, and using Stata version 16 (StataCorp LLC, College Station, TX, USA), the obtained data were analyzed. Using a random-effect meta-analysis approach, we determined the pooled sensitivity and specificity. Utilizing the funnel plot and Begg's and Egger's tests, we assessed publication bias. The results exhibited pooled sensitivity and pooled specificity of 0.80% and 0.89%, respectively, with a 95% confidence interval (CI) of 0.76-0.84 and 0.87-0.92, respectively. The 2018 version of LI-RADS showed the greatest sensitivity (0.83%; 95% CI 0.79-0.87; I 2 = 80.6%; P < 0.001 for heterogeneity; T 2 = 0.001). The maximum pooled specificity was detected in LI-RADS version 2014 (American College of Radiology, Reston, VA, USA; 93.0%; 95% CI 89.0-96.0; I 2 = 81.7%; P < 0.001 for heterogeneity; T 2 = 0.001). In this review, the results of estimated sensitivity and specificity were satisfactory. Therefore, this strategy can serve as an appropriate tool for identifying HCC.
Collapse
|
2
|
Wang W, Liu JY, Yang Z, Wang YF, Shen SL, Yi FL, Huang Y, Xu EJ, Xie XY, Lu MD, Wang Z, Chen LD. Hepatocellular adenoma: comparison between real-time contrast-enhanced ultrasound and dynamic computed tomography. SPRINGERPLUS 2016; 5:951. [PMID: 27386395 PMCID: PMC4929102 DOI: 10.1186/s40064-016-2406-z] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/04/2015] [Accepted: 05/24/2016] [Indexed: 12/14/2022]
Abstract
Purpose To investigate and compare the contrast-enhanced ultrasound (CEUS) features of histologically proven HCA with those of contrast-enhanced computed tomography (CECT). Methods Eighteen patients with proven hepatic adenoma by pathology were retrospectively selected from the CEUS database. Fourteen of them had undergone liver CECT exams. The basic features on unenhanced imaging and the enhancement level and specific features on contrast-enhanced imaging were retrospectively analyzed, and the differences between CEUS and CECT were compared. Results All the HCAs showed hyper-enhancement in the arterial phase. During the portal and late phases, 12 HCAs (12/18, 66.7 %) on CEUS and 11 (11/14, 78.6 %) on CT showed washout. On CEUS, 10 (10/18, 55.5 %) showed centripetal filling in the arterial phase and persistent peripheral rim enhancement. Five of them (61.1 %, 11/18) showed delayed central washout in the portal or late phase. However, on CECT, 2 (14.3 %, 2/14) and 4 (28.6 %, 4/14) HCAs showed persistent enhancement of the peripheral rim and central non-enhancing hemorrhage areas, respectively. Conclusions Compared with dynamic CT, CEUS was superior at characterizing specific dynamic features. Considering that it is radiation-free, readily availability and easy to use, CEUS is suggested as the first line imaging tool to diagnose HCA.
Collapse
Affiliation(s)
- Wei Wang
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Jin-Ya Liu
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Zheng Yang
- Department of Pathology, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Yue-Feng Wang
- Department of Pathology, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Shun-Li Shen
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Feng-Lian Yi
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Yang Huang
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Er-Jiao Xu
- Department of Radiology, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China.,Department of Medical Ultrasonics, The Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Xiao-Yan Xie
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Ming-De Lu
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Zhu Wang
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
| | - Li-Da Chen
- Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China
| |
Collapse
|
3
|
Joshi P, George RA, Tyagi AK, Sinha A. Efficacy of contrast enhanced grey scale ultrasound in characterisation of hepatic focal lesions: A pilot study. Med J Armed Forces India 2014; 70:230-6. [PMID: 25378775 DOI: 10.1016/j.mjafi.2014.05.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2013] [Accepted: 05/25/2014] [Indexed: 11/29/2022] Open
Abstract
BACKGROUND Contrast enhanced ultrasound (CEUS) has recently gained widespread acceptance as an adjunct to conventional grey scale ultrasound. The present pilot study was undertaken to evaluate the efficacy of this technique in characterisation of hepatic focal lesions. METHODS Adult patients who had at least one focal liver lesion underwent ultrasound evaluation in regular and contrast mode before and after intravenous administration of sulphur hexafluoride. The diagnoses were confirmed by comparison with a reference standard (multidetector CT), response to treatment or pathological correlation. RESULTS The rate of correct diagnosis for unenhanced ultrasound was 54%, CEUS was 72% and multidetector CT (MDCT) was 92%. A comparison of unenhanced ultrasound versus CEUS using the McNemar test yielded a p value of 0.0704 (>0.05). However, comparison of CEUS versus MDCT using the McNemar test yielded a p value of 0.0265 (<0.05). Additionally, comparison of unenhanced ultrasound versus MDCT using the McNemar test yielded a p value of <0.0001. CONCLUSION CEUS increases diagnostic efficacy over unenhanced ultrasound but does not have any significant advantages over MDCT. Currently it may be used as a problem solving tool in atypical haemangiomas, echogenic focal liver lesions, contrast sensitivity and to avoid multiple studies utilising ionising radiation.
Collapse
Affiliation(s)
- P Joshi
- Classified Specialist (Radiodiagnosis), INHS Asvini, Colaba, Mumbai 400005, India
| | - R A George
- Senior Advisor (Radiodiagnosis), Command Hospital (Air Force), Bangalore 560007, India
| | - A K Tyagi
- Senior Advisor (Surgery and Surgical Oncology), Army Hospital (R&R), Delhi Cantt, India
| | - Anamika Sinha
- Classified Specialist (Pathology), Command Hospital (Northern Command), C/o 56 APO, India
| |
Collapse
|
4
|
Denecke T, Steffen IG, Agarwal S, Seehofer D, Kröncke T, Hänninen EL, Kramme IB, Neuhaus P, Saini S, Hamm B, Grieser C. Appearance of hepatocellular adenomas on gadoxetic acid-enhanced MRI. Eur Radiol 2012; 22:1769-75. [PMID: 22437921 DOI: 10.1007/s00330-012-2422-5] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2011] [Revised: 01/12/2012] [Accepted: 01/21/2012] [Indexed: 12/13/2022]
Abstract
OBJECTIVE The purpose of this study was to evaluate enhancement characteristics of hepatocellular adenomas (HCAs) using gadoxetic acid as a hepatocyte-specific MR contrast agent. METHODS Twenty-four patients with histopathologically proven HCAs were retrospectively identified. MRI consisted of T1- and T2-weighted (w) sequences with and without fat saturation (fs), multiphase dynamic T1-w images, and fs T1-w images during the hepatobiliary phase. Standard of reference was surgical resection (n = 19) or biopsy (n = 5). Images were analysed for morphology and contrast behaviour including signal intensity (SI) measurement on T1-w images normalised to the pre-contrast base line. RESULTS In total 34 HCAs were evaluated. All HCAs showed enhancement in the arterial phase; 38 % of HCAs showed reduced contrast enhancement ("wash-out") in the venous phase. All HCAs showed enhancement (SI increase, 56 ± 53 %; P <0.001) in the hepatobiliary phase, although liver uptake was stronger (96 ± 58 %). Thus, 31 of all HCAs (91 %) appeared hypointense to the surrounding liver in the hepatobiliary phase, while 3 out of 34 lesions were iso-/hyperintense. CONCLUSIONS Gadoxetic acid accumulates in HCAs in the hepatobiliary phase, although significantly less than in surrounding liver. Thus, HCA appears in the vast majority of cases as a hypointense lesion on hepatobiliary phase images. KEY POINTS • Magnetic resonance-specific contrast agents are now available for hepatic imaging. • Hepatocellular adenomas enhance with gadoxetic acid as in previous CT/MRI experience. • Enhancement during the hepatobiliary phase is less in HCAs than in liver. • Typical HCAs appear as hypointense lesions on T1-w hepatobiliary phase images. • True hyperintense HCA enhancement can occasionally occur during the hepatobiliary phase.
Collapse
Affiliation(s)
- Timm Denecke
- Klinik für Radiologie, Campus Virchow-Klinikum, Charité-Universitätsmedizin Berlin, Augustenburger Platz 1, 13353 Berlin, Germany
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
5
|
Anaye A, Perrenoud G, Rognin N, Arditi M, Mercier L, Frinking P, Ruffieux C, Peetrons P, Meuli R, Meuwly JY. Differentiation of focal liver lesions: usefulness of parametric imaging with contrast-enhanced US. Radiology 2011; 261:300-10. [PMID: 21746815 DOI: 10.1148/radiol.11101866] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
PURPOSE To evaluate whether parametric imaging with contrast material-enhanced ultrasonography (US) is superior to visual assessment for the differential diagnosis of focal liver lesions (FLLs). MATERIALS AND METHODS This study had institutional review board approval, and verbal patient informed consent was obtained. Between August 2005 and October 2008, 146 FLLs in 145 patients (63 women, 82 men; mean age, 62.5 years; age range, 22-89 years) were imaged with real-time low-mechanical-index contrast-enhanced US after a bolus injection of 2.4 mL of a second-generation contrast agent. Clips showing contrast agent uptake kinetics (including arterial, portal, and late phases) were recorded and subsequently analyzed off-line with dedicated image processing software. Analysis of the dynamic vascular patterns (DVPs) of lesions with respect to adjacent parenchyma allowed mapping DVP signatures on a single parametric image. Cine loops of contrast-enhanced US and results from parametric imaging of DVP were assessed separately by three independent off-site readers who classified each lesion as benign, malignant, or indeterminate. Sensitivity, specificity, accuracy, and positive and negative predictive values were calculated for both techniques. Interobserver agreement (κ statistics) was determined. RESULTS Sensitivities for visual interpretation of cine loops for the three readers were 85.0%, 77.9%, and 87.6%, which improved significantly to 96.5%, 97.3%, and 96.5% for parametric imaging, respectively (P < .05, McNemar test), while retaining high specificity (90.9% for all three readers). Accuracy scores of parametric imaging were higher than those of conventional contrast-enhanced US for all three readers (P < .001, McNemar test). Interobserver agreement increased with DVP parametric imaging compared with conventional contrast-enhanced US (change of κ from 0.54 to 0.99). CONCLUSION Parametric imaging of DVP improves diagnostic performance of contrast-enhanced US in the differentiation between malignant and benign FLLs; it also provides excellent interobserver agreement.
Collapse
Affiliation(s)
- Anass Anaye
- Department of Diagnostic and Interventional Radiology and Center for Clinical Epidemiology, Institute for Social and Preventive Medicine, University Hospital Lausanne, Switzerland.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
6
|
Biologic and clinical features of benign solid and cystic lesions of the liver. Clin Gastroenterol Hepatol 2011; 9:547-62.e1-4. [PMID: 21397723 DOI: 10.1016/j.cgh.2011.03.007] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/26/2010] [Revised: 02/24/2011] [Accepted: 03/02/2011] [Indexed: 02/07/2023]
Abstract
The widespread use of imaging analyses, either routinely or to evaluate symptomatic patients, has increased the detection of liver lesions (tumors and cysts) in otherwise healthy individuals. Although some of these incidentally discovered masses are malignant, most are benign and must be included in the differential diagnosis. The management of benign hepatic tumors ranges from conservative to aggressive, depending on the nature of the lesions. New imaging modalities, increased experience of radiologists, improved definition of radiologic characteristics, and a better understanding of the clinical features of these lesions have increased the accuracy of diagnoses and reduced the need for invasive diagnostic tests. These advances have led to constant adjustments in management approaches to benign hepatic lesions. We review the biologic and clinical features of some common hepatic lesions, to guide diagnosis and management strategies.
Collapse
|
7
|
Liu P, Wang X, Zhou S, Hua X, Liu Z, Gao Y. Effects of a novel ultrasound contrast agent with long persistence on right ventricular pressure: Comparison with SonoVue. ULTRASONICS 2011; 51:210-214. [PMID: 20825961 DOI: 10.1016/j.ultras.2010.07.008] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/31/2010] [Revised: 07/15/2010] [Accepted: 07/22/2010] [Indexed: 05/29/2023]
Abstract
This work investigated the effect of infusion of a self-made ultrasound contrast agent with long persistence (named ZHIFUXIAN) on rat right ventricular pressure and made a preliminary evaluation on the relative safety of the novel microbubbles. Normal saline, SonoVue and ZHIFUXIAN were injected through caudal vein at the total volume of 0.5ml for each injection. The right ventricular systolic pressure (RVSP) and end-diastolic pressure (RVEDP) were monitored and the changes of the pressure were compared with baseline readings. RVSP increased when saline, SonoVue or ZHIFUXIAN were injected, the greatest change being after SonoVue (about 2mmHg), but there was no statistical significance compared with baseline (P>0.05). There was no significant difference in RVSP between saline, SonoVue and ZHIFUXIAN at any time point. Also, there was no significant difference in RVEDP between groups at each time point and between different time points in each group. The results indicate that the self-made microbubbles effect on right ventricular hemodynamics is equivalent to that of normal saline at the same volume needed for effective enhanced imaging, demonstrating that it does not produce changes in right ventricular blood pressure under the study conditions. Pathological examination also showed it had no obvious influence on lung, liver and kidney.
Collapse
Affiliation(s)
- Ping Liu
- Department of Ultrasound, Xinqiao Hospital of the Third Military Medical University, Chongqing 400037, China
| | | | | | | | | | | |
Collapse
|
8
|
Abstract
OBJECTIVE Ultrasound (US) technologies are rapidly advancing, offering several refined transducer technologies as well as soft and hardware facilities. The aim of this article is to outline US developments, from B-mode technologies over Doppler advances to more sophisticated technologies, and their potential clinical impact in the field of musculoskeletal (MSK) imaging. NEW ADVANCES When using B-mode ultrasound, compound imaging and beam-steering are of help to decrease anisotropy in tendons and ligaments, that are less well depicted due to their oblique course. Doppler imaging has become sensitive in the detection of flow in small vessels, which is of particular value in rheumatologic conditions, tumour and overuse assessment. The use of US microbubble contrast agents improves detection of low-volume blood flow in smaller vessels by increasing the signal-to-noise ratio and thereby facilitating detection of angiogenetic vessels in inflammatory conditions or tumours. The use of US blood pool contrast agents enables molecular imaging in real-time, and thus the diagnostic potential of US is expanded, opening up a new field of US applications. Objective quantification of altered tissue (e.g., synovial proliferation, tumours) is still demanding and might be improved by the use of three-dimensional imaging and software tools as parametric evaluation. Real-time sonoelastography (EUS) is a new development for visualization of tissue elasticity by measurement of tissue displacement in terms of tissue stiffness changes, promising new insights into tendon disorders. Image fusion is an exciting development that enables superimposition of CT/MRI data sets on real-time US scanning. This technique might be helpful in guiding injections under real-time conditions even in regions less easily accessible by US as, for instance, the axial skeleton, and can additionally provide an interesting tool for teaching MSK imaging and ways to guide interventions. CONCLUSION In summary, exciting developments are expanding the applications of US in the MSK field, offering the advantages of real-time performance, high tissue resolution and relative speed at a reasonable cost.
Collapse
Affiliation(s)
- Andrea S Klauser
- Department of Diagnostic Radiology, Medical University Innsbruck, Austria, Anichstrasse 35, 6020, Innsbruck, Austria.
| | | |
Collapse
|
9
|
Yu M, Liu Q, Song HP, Han ZH, Su HL, He GB, Zhou XD. Clinical application of contrast-enhanced ultrasonography in diagnosis of superficial lymphadenopathy. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2010; 29:735-40. [PMID: 20427785 DOI: 10.7863/jum.2010.29.5.735] [Citation(s) in RCA: 48] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
OBJECTIVE The purpose of this study was to evaluate the value of contrast-enhanced ultrasonography (CEUS) in differential diagnosis of superficial lymphadenopathy. METHODS Ninety-four superficial enlarged lymph nodes in 94 patients were studied by conventional ultrasonography (gray scale and color Doppler) and CEUS. Contrast-enhanced sonograms were analyzed using contrast-specific quantification software. All of the results were compared with pathologic diagnoses. RESULTS Of the 94 lymph nodes examined, 44 were benign and 50 were malignant (33 metastases and 17 lymphomas). The sensitivity, specificity, and accuracy of conventional ultrasonography in differential diagnosis between benign and malignant nodes were 51%, 47%, and 55%, respectively. Contrast-enhanced ultrasonography showed intense homogeneous enhancement in 39 of 44 benign lymph nodes, inhomogeneous enhancement in 32 of 33 metastases, and intense homogeneous enhancement and absence of perfusion in 9 of 17 and 6 of 17 lymphomas, respectively. The sensitivity specificity, and accuracy of CEUS were 84%, 79%, and 80%. After time-intensity curve gamma variates were calculated, the area under the curve of the benign lymph nodes was greater than those of the metastatic lymph nodes and lymphomas (P < .01). CONCLUSIONS These results indicate that the use of CEUS and contrast-specific software has a higher degree of diagnostic accuracy than conventional ultrasonography for evaluations of superficial lymphadenopathy. The contrast enhancement patterns and time-intensity curves provide valuable diagnostic information for differential diagnosis of benign and malignant lymph nodes.
Collapse
Affiliation(s)
- Ming Yu
- Department of Ultrasound, Xijing Hospital, Fourth Military Medical University, Xi'an, China
| | | | | | | | | | | | | |
Collapse
|
10
|
|