1
|
Su S, Ye J, Ke H, Zhong H, Lyu G, Xu Z. Multimodal ultrasound imaging: a method to improve the accuracy of sentinel lymph node diagnosis in breast cancer. Front Oncol 2024; 14:1366876. [PMID: 38590661 PMCID: PMC10999636 DOI: 10.3389/fonc.2024.1366876] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2024] [Accepted: 03/08/2024] [Indexed: 04/10/2024] Open
Abstract
Aim This study assessed the utility of multimodal ultrasound in enhancing the accuracy of breast cancer sentinel lymph node (SLN) assessment and compared it with single-modality ultrasound. Methods Preoperative examinations, including two-dimensional ultrasound (2D US), intradermal contrast-enhanced ultrasound (CEUS), intravenous CEUS, shear-wave elastography (SWE), and surface localization, were conducted on 86 SLNs from breast cancer patients. The diagnostic performance of single and multimodal approaches for detecting metastatic SLNs was compared to postoperative pathological results. Results Among the 86 SLNs, 29 were pathologically diagnosed as metastatic, and 57 as non-metastatic. Single-modality ultrasounds had AUC values of 0.826 (intradermal CEUS), 0.705 (intravenous CEUS), 0.678 (2D US), and 0.677 (SWE), respectively. Intradermal CEUS significantly outperformed the other methods (p<0.05), while the remaining three methods had no statistically significant differences (p>0.05). Multimodal ultrasound, combining intradermal CEUS, intravenous CEUS, 2D US, and SWE, achieved an AUC of 0.893, with 86.21% sensitivity and 84.21% specificity. The DeLong test confirmed that multimodal ultrasound was significantly better than the four single-modal ultrasound methods (p<0.05). Decision curve analysis and clinical impact curves demonstrated the superior performance of multimodal ultrasound in identifying high-risk SLN patients. Conclusion Multimodal ultrasound improves breast cancer SLN identification and diagnostic accuracy.
Collapse
Affiliation(s)
- Shanshan Su
- Department of Ultrasound in Medicine, The Second Affiliated Hospital of Fujian Medical University, Quanzhou, China
| | - Jiayi Ye
- Department of Radiology, The Second Affiliated Hospital of Fujian Medical University, Quanzhou, China
| | - Helin Ke
- Department of Ultrasound in Medicine, The Second Affiliated Hospital of Fujian Medical University, Quanzhou, China
| | - Huohu Zhong
- Department of Ultrasound in Medicine, The Second Affiliated Hospital of Fujian Medical University, Quanzhou, China
| | - Guorong Lyu
- Department of Ultrasound in Medicine, The Second Affiliated Hospital of Fujian Medical University, Quanzhou, China
| | - Zhirong Xu
- Department of Ultrasound in Medicine, The Second Affiliated Hospital of Fujian Medical University, Quanzhou, China
| |
Collapse
|
2
|
Ramesh A, Rohan K, Nagarajan K, Abdulbasith KM, Sureshkumar S, Vijayakumar C, Balamourougan K, Srinivas BH. Evaluation of acoustic radiation force impulse imaging in differentiating benign and malignant cervical lymphadenopathy. J Med Ultrasound 2022; 30:87-93. [PMID: 35832364 PMCID: PMC9272720 DOI: 10.4103/jmu.jmu_10_21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2021] [Revised: 03/21/2021] [Accepted: 06/04/2021] [Indexed: 11/10/2022] Open
Abstract
Background: The aim of this study was to assess the diagnostic role of acoustic radiation force impulse imaging (ARFI) in differentiating benign and malignant cervical nodes. Methods: This was a diagnostic accuracy cross-sectional study. All patients who underwent ultrasound-guided fine-needle aspiration cytology (FNAC) of cervical nodes were included. Patients without FNAC/biopsy and patients in whom cervical nodes were cystic or completely necrotic were excluded. FNAC was used as reference investigation to predict the diagnostic accuracy. In all cases, FNAC was carried out after the B-mode, color Doppler and the ARFI imaging. In patients with multiple cervical lymph nodes, the most suspicious node based on grayscale findings was chosen for ARFI. ARFI included Virtual Touch imaging (VTI), area ratio (AR), and shear wave velocity (SWV) for each node, and the results were compared with FNAC/biopsy. Results: The final analysis included 166 patients. Dark VTI elastograms had sensitivity and specificity of 86.2% and 72.1%, respectively, in identifying malignant nodes. Sensitivity and specificity of AR were 71.3% and 82.3%, respectively, for a cutoff of 1.155. Median SWV of benign and malignant nodes was 1.9 [95% confidence interval (CI), 1.56–2.55] m/s and 6.7 (95% CI, 2.87–9.10) m/s, respectively. SWV >2.68 m/s helped in identifying malignant nodes with 81% specificity, 81.6% sensitivity, and 81.3% accuracy. ARFI was found to be inaccurate in tuberculous and lymphomatous nodes. Conclusion: Malignant nodes had significantly darker elastograms, higher AR and SWV compared to benign nodes, and SWV was the most accurate parameter. ARFI accurately identifies malignant nodes, hence could potentially avoid unwarranted biopsy.
Collapse
|
3
|
Tavarozzi R, Manzato E, Lombardi A. Lymph Node Ultrasound in Lymphoproliferative Disorders: Where Are We Now? J Clin Imaging Sci 2021; 11:22. [PMID: 33948338 PMCID: PMC8088481 DOI: 10.25259/jcis_31_2021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2021] [Accepted: 03/30/2021] [Indexed: 11/05/2022] Open
Abstract
Lymphoproliferative disorders are one of the most frequent hematological malignancies affecting the blood and lymphatic system. To better stratify patients, an accurate imaging evaluation is needed. Although computed tomography and positron emission tomography are considered the standard methods, these procedures have several clinical drawbacks, such as biological risk and high costs. Ultrasound (US) is a rapid and user-friendly method to evaluate lymph node (LN) and organ enlargements. US imaging provides more sensitive information about LN structure, vascularization, and metabolism and new techniques have increased its specificity, especially in malignant setting. However, validated and standardized criteria for its use are missing, with only several single-center experiences reported. Therefore, the aim of this paper is to review and briefly illustrate the status of the US knowledge and applications in lymphoproliferative workup, particularly concerning malignant LN pathology.
Collapse
Affiliation(s)
- Rita Tavarozzi
- Department of Hematology, AON SS Antonio e Biagio e Cesare Arrigo, Alessandria
| | - Enrica Manzato
- Department of Medicine, Sant'Anna School of Advanced Studies, Pisa
| | - Anna Lombardi
- Department of Emergency, A.O.R.N. Antonio Cardarelli, Naples, Italy
| |
Collapse
|
4
|
Li J, Chen M, Cao CL, Zhou LQ, Li SG, Ge ZK, Zhang WH, Xu JW, Cui XW, Dietrich CF. Diagnostic Performance of Acoustic Radiation Force Impulse Elastography for the Differentiation of Benign and Malignant Superficial Lymph Nodes: A Meta-analysis. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2020; 39:213-222. [PMID: 31343772 DOI: 10.1002/jum.15096] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/30/2019] [Revised: 06/18/2019] [Accepted: 06/24/2019] [Indexed: 06/10/2023]
Abstract
To estimate the diagnostic performance of acoustic radiation force impulse elastography in distinguishing between benign and malignant superficial lymph nodes, relevant articles published before October 31, 2018, in China and other countries were used. Conclusively, a total of 18 articles were analyzed. Sixteen studies used Virtual Touch tissue quantification (Siemens Healthineers, Erlangen, Germany), and 4 studies used Virtual Touch tissue imaging (Siemens Healthineers). After a meta-analysis, it was found that acoustic radiation force impulse elastography is an efficient method for detecting superficial lymph nodes. In addition, if the cutoff value for the shear wave velocity were less than 2.85 m/s, the summary sensitivity would increase, and the heterogeneity would be reduced.
Collapse
Affiliation(s)
- Jun Li
- Department of Medical Ultrasound, First Affiliated Hospital of Medical College, Shihezi University, Shihezi, China
| | - Ming Chen
- Department of Medical Ultrasound, First Affiliated Hospital of Medical College, Shihezi University, Shihezi, China
| | - Chun-Li Cao
- Department of Medical Ultrasound, First Affiliated Hospital of Medical College, Shihezi University, Shihezi, China
| | - Li-Qiang Zhou
- Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Shu-Gang Li
- Department of Public Health, Medical College, Shihezi University, Shihezi, China
| | - Zong-Kai Ge
- Department of Internal Medicine, Occupational Disease Prevention and Treatment Center, China Pingmei Shenma Group, Pingdingshan, China
| | - Wei-Hong Zhang
- Department of Medical Ultrasound, First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Jian-Wei Xu
- Department of Medical Ultrasound, First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Xin-Wu Cui
- Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Christoph F Dietrich
- Medical Clinic 2, Caritas-Krankenhaus Bad Mergentheim, Academic Teaching Hospital of the University of Würzburg, Bad Mergentheim, Germany
| |
Collapse
|
5
|
Predictive value of comb-push ultrasound shear elastography for the differentiation of reactive and metastatic axillary lymph nodes: A preliminary investigation. PLoS One 2020; 15:e0226994. [PMID: 31929558 PMCID: PMC6957145 DOI: 10.1371/journal.pone.0226994] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2019] [Accepted: 12/09/2019] [Indexed: 12/01/2022] Open
Abstract
Objectives To evaluate the predictive performance of comb-push ultrasound shear elastography for the differentiation of reactive and metastatic axillary lymph nodes. Methods From June 2014 through September 2018, 114 female volunteers (mean age 58.1±13.3 years; range 28–88 years) with enlarged axillary lymph nodes identified by palpation or clinical imaging were prospectively enrolled in the study. Mean, standard deviation and maximum shear wave elastography parameters from 117 lymph nodes were obtained and compared to fine needle aspiration biopsy results. Mann-Whitney U test and ROC curve analysis were performed. Results The axillary lymph nodes were classified as reactive or metastatic based on the fine needle aspiration outcomes. A statistically significant difference between reactive and metastatic axillary lymph nodes was observed based on comb-push ultrasound shear elastography (CUSE) results (p<0.0001) from mean and maximum elasticity values. Mean elasticity showed the best separation with a ROC analysis resulting in 90.5% sensitivity, 94.4% specificity, 0.97 area under the curve, 95% positive predictive value, and 89.5% negative predictive value with a 30.2-kPa threshold. Conclusions CUSE provided a quantifiable parameter that can be used for the assessment of enlarged axillary lymph nodes to differentiate between reactive and metastatic processes.
Collapse
|
6
|
Xin L, Yan Z, Zhang X, Zang Y, Ding Z, Xue H, Zhao C. Parameters for Contrast-Enhanced Ultrasound (CEUS) of Enlarged Superficial Lymph Nodes for the Evaluation of Therapeutic Response in Lymphoma: A Preliminary Study. Med Sci Monit 2017; 23:5430-5438. [PMID: 29138385 PMCID: PMC5700665 DOI: 10.12659/msm.907293] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2017] [Accepted: 10/16/2017] [Indexed: 11/16/2022] Open
Abstract
BACKGROUND The aims of this preliminary study were to evaluate contrast-enhanced ultrasound (CEUS) imaging and the therapeutic response of enlarged superficial lymph nodes in patients with lymphoma before and after chemotherapy and to determine the most useful CEUS response parameters. MATERIAL AND METHODS Forty-three patients with lymphoma, with 43 enlarged superficial lymph nodes, underwent CEUS and conventional ultrasound (US), before treatment and after the first three cycles of chemotherapy. Clinical responses included overall response (OR) and no response (NR). Imaging parameters by time-intensity curve (TIC) included basic intensity (B), wash-out slope and/or decent slope (K), wash-in slope or rise slope (C), time to peak (TTP), area under the gamma curve (Area), arrive time(ATM), peak intensity (PI), change of peak intensity (I) were compared. And receiver operating characteristic (ROC) curve analysis was operated. RESULTS Quantitative parameters of CEUS before and after the first three cycles of chemotherapy showed a significant difference in the AreaΔ, PID, and IΔ in the OR group compared with NR group (P<0.05). There was a significant difference in the Cpre, Areain, PIin, Iin, AreaΔ, PIΔ, and IΔ in the OR group compared with NR group (P<0.05). The effectiveness of the therapeutic response was predicted by the CEUS parameters of IΔ (P<0.05). And ΔArea has the highest diagnostic performance of ineffectiveness. CONCLUSIONS The findings of this study have shown that quantitative analysis by CEUS may be a useful, and objective, imaging method for the evaluation of the therapeutic response of enlarged superficial lymph nodes in lymphoma before and after chemotherapy.
Collapse
Affiliation(s)
- Lei Xin
- Department of Ultrasound, The Affiliated Hospital of Qingdao University, Qingdao, Shandong, P.R. China
| | - Zhimei Yan
- Department of Ultrasound, The Affiliated Hospital of Qingdao University, Qingdao, Shandong, P.R. China
| | - Xiaojuan Zhang
- Department of Ultrasound, The Affiliated Hospital of Qingdao University, Qingdao, Shandong, P.R. China
| | - Yichen Zang
- Department of Ultrasound, The Affiliated Hospital of Qingdao University, Qingdao, Shandong, P.R. China
| | - Zhaoyan Ding
- Department of Ultrasound, The Affiliated Hospital of Qingdao University, Qingdao, Shandong, P.R. China
| | - Hongwei Xue
- Department of Lymphoma, The Affiliated Hospital of Qingdao University, Qingdao, Shandong, P.R. China
| | - Cheng Zhao
- Department of Ultrasound, The Affiliated Hospital of Qingdao University, Qingdao, Shandong, P.R. China
| |
Collapse
|
7
|
Zhang F, Zhao X, Ji X, Han R, Li P, Du M. Diagnostic value of acoustic radiation force impulse imaging for assessing superficial lymph nodes: A diagnostic accuracy study. Medicine (Baltimore) 2017; 96:e8125. [PMID: 29068984 PMCID: PMC5671817 DOI: 10.1097/md.0000000000008125] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
The aim of this study was to assess the diagnostic value of acoustic radiation force impulse (ARFI) imaging for differentiating superficial lymph nodes.Virtual touch tissue imaging (VTI) grade and shear wave velocity (SWV) were analyzed and compared in 97 patients (65 women, 32 men; mean age, 49 y; range, 23-72 y) with 97 lymph nodes [23 chronic nonspecific reactive lymph nodes (CLNs), 38 metastatic lymph nodes (MLNs), and 36 blood and lymphatic system diseases lymph nodes (BLLNs)]. The elastography characteristics in patients with CLNs, MLNs, and BLLNs were compared using the nonparametric Kruskal-Wallis test and Mann-Whitney U test for continuous variables and categorical variables. The diagnostic performance of VTI grade and SWV were evaluated using the area under the receiver operating characteristic curve (AUC).The median of SWV of MLNs was significantly higher (2.90 m/s) than those of CLNs (2.15 m/s) and BLLNs (2.52 m/s). The VTI grade of MLNs was significantly higher than those of CLNs (P < .001) and BLLNs (P < .001). The sensitivity, specificity, accuracy, and AUC were 81.58%, 95.65%, 86.89%, and 0.904, respectively, at a cutoff level of grade IV for VTI grade in differentiating MLNs from CLNs, whereas those of SWV were 57.89%, 86.96%, 68.85%, and 0.752, respectively, at a cutoff level of 2.76 m/s.The diagnostic performance of VTI grade was significantly higher than that of SWV in differentiating MLNs from CLNs. The diagnostic performance of VTI grade and SWV were lower intermediate in differentiating MLNs from BLLNs and in differentiating BLLNs from CLNs, and there was no significant difference between VTI grade and SWV. ARFI imaging may be a feasible method for differentiating MLNs from CLNs.
Collapse
Affiliation(s)
- Fengjuan Zhang
- Department of Ultrasound, the Fourth Hospital of Hebei Medical University
| | - Xinming Zhao
- Department of Nuclear Medicine and Medical Imaging, the Fourth Hospital of Hebei Medical University, Hebei, Shijiazhuang, China
| | - Xiaohui Ji
- Department of Ultrasound, the Fourth Hospital of Hebei Medical University
| | - Ruoling Han
- Department of Ultrasound, the Fourth Hospital of Hebei Medical University
| | - Ping Li
- Department of Ultrasound, the Fourth Hospital of Hebei Medical University
| | - Min Du
- Department of Ultrasound, the Fourth Hospital of Hebei Medical University
| |
Collapse
|
8
|
Acoustic Radiation Force Impulse Imaging for the Differentiation of Benign and Malignant Lymph Nodes: A Systematic Review and Meta-Analysis. PLoS One 2016; 11:e0166716. [PMID: 27855188 PMCID: PMC5113967 DOI: 10.1371/journal.pone.0166716] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2016] [Accepted: 11/02/2016] [Indexed: 01/08/2023] Open
Abstract
Objective To evaluate the overall performance of acoustic radiation force impulse imaging (ARFI) in differentiating between benign and malignant lymph nodes (LNs) by conducting a meta-analysis. Methods PubMed, Embase, Web of Science, the Cochrane Library and the China National Knowledge Infrastructure were comprehensively searched for potential studies through August 13th, 2016. Studies that investigated the diagnostic power of ARFI for the differential diagnosis of benign and malignant LNs by using virtual touch tissue quantification (VTQ) or virtual touch tissue imaging quantification (VTIQ) were collected. The included articles were published in English or Chinese. Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) was used to evaluate the methodological quality. The pooled sensitivity, specificity, and the area under the summary receiver operating characteristic (SROC) curve (AUC) were calculated by means of a bivariate mixed-effects regression model. Meta-regression analysis was performed to identify the potential sources of between study heterogeneity. Fagan plot analysis was used to explore the clinical utilities. Publication bias was assessed using Deek’s funnel plot. Results Nine studies involving 1084 LNs from 929 patients were identified to analyze in the meta-analysis. The summary sensitivity and specificity of ARFI in detecting malignant LNs were 0.87 (95% confidence interval [CI], 0.83–0.91) and 0.88 (95% CI, 0.82–0.92), respectively. The AUC was 0.93 (95% CI, 0.90–0.95). The pooled DOR was 49.59 (95% CI, 26.11–94.15). Deek’s funnel plot revealed no significant publication bias. Conclusion ARFI is a promising tool for the differentiation of benign and malignant LNs with high sensitivity and specificity.
Collapse
|