1
|
2D-shear wave elastography in the evaluation of suspicious superficial inguinal lymph nodes: Reproducibility and region of interest selection. PLoS One 2022; 17:e0265802. [PMID: 35344561 PMCID: PMC8959156 DOI: 10.1371/journal.pone.0265802] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2020] [Accepted: 03/08/2022] [Indexed: 12/12/2022] Open
Abstract
Purpose
To assess the ability of 2D-Shear wave elastography (2D-SWE) to evaluate its reproducibility, to define the optimal orientation and size of the region of interest (ROI), and to differentiate benign from malignant inguinal lymph nodes (LNs).
Method
Thirty-two suspicious inguinal LNs from 21 patients were evaluated with 2D-SWE. SWE measurements were obtained in two orthogonal planes. To investigate reproducibility, sensitivity and specificity, circular ROIs with a diameter of 1 mm, 2 mm, 3 mm and 5 mm were placed on the cortex of the LNs. Additionally, one freehand ROI was drawn covering majority of the LN. Two observers performed five sets of SWE measurements for each ROI size. All LNs underwent core needle biopsy or were surgically removed.
Results
The 3 mm ROI for Mean-E in axial plane showed high interrater agreement [intraclass correlation coefficient (ICC) 0.899] with the cut-off value of 7.31 kPa resulting in 88.9% sensitivity and 60.9% specificity for differentiating malignant from benign LNs. In benign LNs, mean elasticity of the ROI was lower (7.68 ± 3.82 kPa; range, 3.41–15.40 kPa) compared to the malignant LNs (15.81 ± 10.61 kPa; range, 3.86–36.45 kPa).
Conclusions
The most reproducible way to measure stiffness in inguinal LNs is a 3 mm circular ROI centered on the cortex of the LN in axial plane. Elasticity values were higher in the malignant LNs reflecting the stiffer nature of the metastatic LNs. 2D-SWE offers a noninvasive ultrasonographic tool to assess superficial inguinal lymph nodes with high reproducibility.
Collapse
|
2
|
Li J, Chen M, Cao CL, Zhou LQ, Li SG, Ge ZK, Zhang WH, Xu JW, Cui XW, Dietrich CF. Diagnostic Performance of Acoustic Radiation Force Impulse Elastography for the Differentiation of Benign and Malignant Superficial Lymph Nodes: A Meta-analysis. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2020; 39:213-222. [PMID: 31343772 DOI: 10.1002/jum.15096] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/30/2019] [Revised: 06/18/2019] [Accepted: 06/24/2019] [Indexed: 06/10/2023]
Abstract
To estimate the diagnostic performance of acoustic radiation force impulse elastography in distinguishing between benign and malignant superficial lymph nodes, relevant articles published before October 31, 2018, in China and other countries were used. Conclusively, a total of 18 articles were analyzed. Sixteen studies used Virtual Touch tissue quantification (Siemens Healthineers, Erlangen, Germany), and 4 studies used Virtual Touch tissue imaging (Siemens Healthineers). After a meta-analysis, it was found that acoustic radiation force impulse elastography is an efficient method for detecting superficial lymph nodes. In addition, if the cutoff value for the shear wave velocity were less than 2.85 m/s, the summary sensitivity would increase, and the heterogeneity would be reduced.
Collapse
Affiliation(s)
- Jun Li
- Department of Medical Ultrasound, First Affiliated Hospital of Medical College, Shihezi University, Shihezi, China
| | - Ming Chen
- Department of Medical Ultrasound, First Affiliated Hospital of Medical College, Shihezi University, Shihezi, China
| | - Chun-Li Cao
- Department of Medical Ultrasound, First Affiliated Hospital of Medical College, Shihezi University, Shihezi, China
| | - Li-Qiang Zhou
- Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Shu-Gang Li
- Department of Public Health, Medical College, Shihezi University, Shihezi, China
| | - Zong-Kai Ge
- Department of Internal Medicine, Occupational Disease Prevention and Treatment Center, China Pingmei Shenma Group, Pingdingshan, China
| | - Wei-Hong Zhang
- Department of Medical Ultrasound, First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Jian-Wei Xu
- Department of Medical Ultrasound, First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Xin-Wu Cui
- Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Christoph F Dietrich
- Medical Clinic 2, Caritas-Krankenhaus Bad Mergentheim, Academic Teaching Hospital of the University of Würzburg, Bad Mergentheim, Germany
| |
Collapse
|
3
|
Comparison of Diagnostic Performance of B-Mode Ultrasonography and Shear Wave Elastography in Cervical Lymph Nodes. Ultrasound Q 2019; 35:290-296. [PMID: 31283566 DOI: 10.1097/ruq.0000000000000464] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
The purpose of this study was to compare the diagnostic performance of B-mode ultrasonography (US) and shear wave elastography (SWE) for differentiating benign from malignant cervical lymph nodes (LNs). This study evaluated 130 cervical LNs in 127 patients. On conventional B-mode US, short-axis and long-axis diameters, long-to-short-axis ratio, cortical morphology, border, and presence of necrosis or calcification were evaluated. Maximum elasticity value (Emax) was collected for SWE. The area under the receiver operator characteristic curve (AUC), sensitivity, and specificity of B-mode US features and SWE were compared. Final histopathologic results showed 89 benign and 41 metastatic LNs. Among the B-mode US features, cortical morphology had the highest AUC (0.884). When 54 kPa of Emax was applied as a cutoff value, the SWE showed significantly lower AUC than cortical morphology (0.734, P = 0.02). Both sensitivity and specificity for cortical morphology on B-mode US were higher than for Emax (80.5% vs 65.9%, P = 0.212 and 89.9% vs 76.4%, P = 0.026, respectively). Conventional B-mode US resulted in higher diagnostic yield than SWE in evaluating cervical LNs in our study. However, further studies on potential factors that may affect the SWE velocity are needed to validate the diagnostic value of SWE.
Collapse
|
4
|
Ben Z, Gao S, Wu W, Chen S, Fu S, Zhang J, Chen Y. Clinical value of the VTIQ technology in the differential diagnosis of superficially enlarged lymph nodes. Acta Radiol 2018; 59:836-844. [PMID: 28927297 DOI: 10.1177/0284185117732601] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
Background Lymph node enlargement is a common clinical finding in clinical practice with different treatment strategies. Purpose To investigate the application of Virtual Touch Image Quantification (VTIQ) to diagnose benign and malignant superficial enlarged lymph nodes. Material and Methods Between December 2015 and August 2016, 116 superficial enlarged lymph nodes were examined by VTIQ. Maximum (Vmax), minimum (Vmin), and average (Vmean) shear wave velocities (SWV) were obtained from the lymph nodes and from normal muscular tissues (Vn) located at the same level and within 5 mm from the target lymph node. The pathological results were used as the gold standard to evaluate VTIQ. Results All 116 patients underwent fine-needle aspiration biopsy for pathological examination. Forty patients had malignant lymph nodes and 76 patients had benign lymph nodes. Lymph node characteristics on B-mode ultrasound showed no differences between malignant and benign lymph nodes, but there were differences in VTIQ parameters (all P < 0.001). Compared with pathological diagnosis as the gold standard, the area under the ROC curves of Vmax, Vmin, and Vmean were 0.815, 0.746, and 0.795. The Vmax cutoff value to diagnose benign from malignant lymph nodes was 3.045 m/s. The sensitivity, specificity, and positive and negative predictive values were 70%, 78.9%, 63.6%, and 83.3%. Conclusion VTIQ has a clinical application in the differential diagnosis of superficial enlarged lymph nodes.
Collapse
Affiliation(s)
- Zhifei Ben
- Department of Ultrasound, Ningbo No. 2 Hospital, Ningbo, Zhejiang, PR China
| | - Shanshan Gao
- Department of Ultrasound, Ningbo No. 2 Hospital, Ningbo, Zhejiang, PR China
| | - Wenjing Wu
- Department of Ultrasound, Ningbo No. 2 Hospital, Ningbo, Zhejiang, PR China
| | - Saijun Chen
- Department of Ultrasound, Ningbo No. 2 Hospital, Ningbo, Zhejiang, PR China
| | - Shuping Fu
- Department of Ultrasound, Ningbo No. 2 Hospital, Ningbo, Zhejiang, PR China
| | - Jianli Zhang
- Department of Ultrasound, Ningbo No. 2 Hospital, Ningbo, Zhejiang, PR China
| | - Yunwen Chen
- Department of Ultrasound, Ningbo No. 2 Hospital, Ningbo, Zhejiang, PR China
| |
Collapse
|
5
|
Ultrasound elastography in pathological enlarged cervical lymph nodes compared to histopathology. THE EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE 2016. [DOI: 10.1016/j.ejrnm.2016.07.008] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
|