1
|
Patel K, Asrani SK, Fiel MI, Levine D, Leung DH, Duarte-Rojo A, Dranoff JA, Nayfeh T, Hasan B, Taddei TH, Alsawaf Y, Saadi S, Majzoub AM, Manolopoulos A, Alzuabi M, Ding J, Sofiyeva N, Murad MH, Alsawas M, Rockey DC, Sterling RK. Accuracy of blood-based biomarkers for staging liver fibrosis in chronic liver disease: A systematic review supporting the AASLD Practice Guideline. Hepatology 2024:01515467-990000000-00805. [PMID: 38489517 DOI: 10.1097/hep.0000000000000842] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/08/2023] [Accepted: 02/19/2024] [Indexed: 03/17/2024]
Abstract
BACKGROUND AND AIMS Blood-based biomarkers have been proposed as an alternative to liver biopsy for noninvasive liver disease assessment in chronic liver disease. Our aims for this systematic review were to evaluate the diagnostic utility of selected blood-based tests either alone, or in combination, for identifying significant fibrosis (F2-4), advanced fibrosis (F3-4), and cirrhosis (F4), as compared to biopsy in chronic liver disease. APPROACH AND RESULTS We included a comprehensive search of databases including Ovid MEDLINE(R), EMBASE, Cochrane Database, and Scopus through to April 2022. Two independent reviewers selected 286 studies with 103,162 patients. The most frequently identified studies included the simple aspartate aminotransferase-to-platelet ratio index and fibrosis (FIB)-4 markers (with low-to-moderate risk of bias) in HBV and HCV, HIV-HCV/HBV coinfection, and NAFLD. Positive (LR+) and negative (LR-) likelihood ratios across direct and indirect biomarker tests for HCV and HBV for F2-4, F3-4, or F4 were 1.66-6.25 and 0.23-0.80, 1.89-5.24 and 0.12-0.64, and 1.32-7.15 and 0.15-0.86, respectively; LR+ and LR- for NAFLD F2-4, F3-4, and F4 were 2.65-3.37 and 0.37-0.39, 2.25-6.76 and 0.07-0.87, and 3.90 and 0.15, respectively. Overall, the proportional odds ratio indicated FIB-4 <1.45 was better than aspartate aminotransferase-to-platelet ratio index <0.5 for F2-4. FIB-4 >3.25 was also better than aspartate aminotransferase-to-platelet ratio index >1.5 for F3-4 and F4. There was limited data for combined tests. CONCLUSIONS Blood-based biomarkers are associated with small-to-moderate change in pretest probability for diagnosing F2-4, F3-4, and F4 in viral hepatitis, HIV-HCV coinfection, and NAFLD, with limited comparative or combination studies for other chronic liver diseases.
Collapse
Affiliation(s)
- Keyur Patel
- Department of Medcine, Division of Gastroenterology and Hepatology, University Health Network, University of Toronto, Toronto, Ontario, Canada
| | - Sumeet K Asrani
- Department of Medicine, Division of Hepatology, Baylor University Medical Center, Dallas, Texas, USA
| | - Maria Isabel Fiel
- Department of Pathology, Molecular and Cell-Based Medicine, Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | - Deborah Levine
- Department of Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
| | - Daniel H Leung
- Department of Pediatrics, Baylor College of Medicine and Division of Gastroenterology, Hepatology and Nutrition, Texas Children's Hospital, Houston, Texas, USA
| | - Andres Duarte-Rojo
- Division of Gastroenterology and Hepatology, Northwestern Medicine and Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - Jonathan A Dranoff
- Yale School of Medicine, Department of Internal Medicine, Section of Digestive Diseases, New Haven, Connecticut, USA
- Mayo Clinic Evidence-based Practice Center, Mayo Clinic, Rochester, Minnesota, USA
| | - Tarek Nayfeh
- Mayo Clinic Evidence-based Practice Center, Mayo Clinic, Rochester, Minnesota, USA
| | - Bashar Hasan
- Mayo Clinic Evidence-based Practice Center, Mayo Clinic, Rochester, Minnesota, USA
| | - Tamar H Taddei
- Yale School of Medicine, Department of Internal Medicine, Section of Digestive Diseases, New Haven, Connecticut, USA
- Mayo Clinic Evidence-based Practice Center, Mayo Clinic, Rochester, Minnesota, USA
| | - Yahya Alsawaf
- Mayo Clinic Evidence-based Practice Center, Mayo Clinic, Rochester, Minnesota, USA
| | - Samer Saadi
- Mayo Clinic Evidence-based Practice Center, Mayo Clinic, Rochester, Minnesota, USA
| | | | | | - Muayad Alzuabi
- Mayo Clinic Evidence-based Practice Center, Mayo Clinic, Rochester, Minnesota, USA
| | - Jingyi Ding
- Mayo Clinic Evidence-based Practice Center, Mayo Clinic, Rochester, Minnesota, USA
| | - Nigar Sofiyeva
- Mayo Clinic Evidence-based Practice Center, Mayo Clinic, Rochester, Minnesota, USA
| | - Mohammad H Murad
- Mayo Clinic Evidence-based Practice Center, Mayo Clinic, Rochester, Minnesota, USA
| | - Mouaz Alsawas
- Mayo Clinic Evidence-based Practice Center, Mayo Clinic, Rochester, Minnesota, USA
- Department of Medicine, Section of Hepatology, Virginia Commonwealth University, Richmond, Virginia, USA
| | - Don C Rockey
- Department of Medicine, Digestive Disease Research Center, Medical University of South Carolina, Charleston, South Carolina, USA
| | - Richard K Sterling
- Department of Medicine, Section of Hepatology, Virginia Commonwealth University, Richmond, Virginia, USA
| |
Collapse
|
2
|
Duarte-Rojo A, Taouli B, Leung DH, Levine D, Nayfeh T, Hasan B, Alsawaf Y, Saadi S, Majzoub AM, Manolopoulos A, Haffar S, Dundar A, Murad MH, Rockey DC, Alsawas M, Sterling RK. Imaging-based noninvasive liver disease assessment for staging liver fibrosis in chronic liver disease: A systematic review supporting the AASLD Practice Guideline. Hepatology 2024:01515467-990000000-00808. [PMID: 38489521 DOI: 10.1097/hep.0000000000000852] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Accepted: 01/19/2024] [Indexed: 03/17/2024]
Abstract
BACKGROUND AND AIMS Transient elastography (TE), shear wave elastography, and/or magnetic resonance elastography (MRE), each providing liver stiffness measurement (LSM), are the most studied imaging-based noninvasive liver disease assessment (NILDA) techniques. To support the American Association for the Study of Liver Diseases guidelines on NILDA, we summarized the evidence on the accuracy of these LSM methods to stage liver fibrosis (F). APPROACH AND RESULTS A comprehensive search for studies assessing LSM by TE, shear wave elastography, or MRE for the identification of significant fibrosis (F2-4), advanced fibrosis (F3-4), or cirrhosis (F4), using histopathology as the standard of reference by liver disease etiology in adults or children from inception to April 2022 was performed. We excluded studies with <50 patients with a single disease entity and mixed liver disease etiologies (with the exception of HCV/HIV coinfection). Out of 9447 studies, 240 with 61,193 patients were included in this systematic review. In adults, sensitivities for the identification of F2-4 ranged from 51% to 95%, for F3-4 from 70% to 100%, and for F4 from 60% to 100% across all techniques/diseases, whereas specificities ranged from 36% to 100%, 74% to 100%, and 67% to 99%, respectively. The largest body of evidence available was for TE; MRE appeared to be the most accurate method. Imaging-based NILDA outperformed blood-based NILDA in most comparisons, particularly for the identification of F3-4/F4. In the pediatric population, imaging-based NILDA is likely as accurate as in adults. CONCLUSIONS LSM from TE, shear wave elastography, and MRE shows acceptable to outstanding accuracy for the detection of liver fibrosis across various liver disease etiologies. Accuracy increased from F2-4 to F3-4 and was the highest for F4. Further research is needed to better standardize the use of imaging-based NILDA, particularly in pediatric liver diseases.
Collapse
Affiliation(s)
- Andres Duarte-Rojo
- Division of Gastroenterology and Hepatology, Northwestern Medicine and Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - Bachir Taouli
- Department of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | - Daniel H Leung
- Department of Pediatrics, Baylor College of Medicine and Division of Gastroenterology, Hepatology and Nutrition, Texas Children's Hospital, Houston, Texas, USA
| | - Deborah Levine
- Department of Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
| | - Tarek Nayfeh
- Mayo Clinic Evidence-based Practice Center, Mayo Clinic, Rochester, Minnesota, USA
| | - Bashar Hasan
- Mayo Clinic Evidence-based Practice Center, Mayo Clinic, Rochester, Minnesota, USA
| | - Yahya Alsawaf
- Mayo Clinic Evidence-based Practice Center, Mayo Clinic, Rochester, Minnesota, USA
| | - Samer Saadi
- Mayo Clinic Evidence-based Practice Center, Mayo Clinic, Rochester, Minnesota, USA
| | | | | | - Samir Haffar
- Mayo Clinic Evidence-based Practice Center, Mayo Clinic, Rochester, Minnesota, USA
| | - Ayca Dundar
- Mayo Clinic Evidence-based Practice Center, Mayo Clinic, Rochester, Minnesota, USA
| | - M Hassan Murad
- Mayo Clinic Evidence-based Practice Center, Mayo Clinic, Rochester, Minnesota, USA
| | - Don C Rockey
- Digestive Disease Research Center, Medical University of South Carolina, Charleston, South Carolina, USA
| | - Mouaz Alsawas
- Mayo Clinic Evidence-based Practice Center, Mayo Clinic, Rochester, Minnesota, USA
| | - Richard K Sterling
- Section of Hepatology, Department of Medicine, Virginia Commonwealth University, Richmond, Virginia, USA
| |
Collapse
|
3
|
Schambeck JPL, Forte GC, Gonçalves LM, Stuker G, Kotlinski JBF, Tramontin G, Altmayer S, Watte G, Hochhegger B. Diagnostic accuracy of magnetic resonance elastography and point-shear wave elastography for significant hepatic fibrosis screening: Systematic review and meta-analysis. PLoS One 2023; 18:e0271572. [PMID: 36730265 PMCID: PMC9894488 DOI: 10.1371/journal.pone.0271572] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2021] [Accepted: 07/03/2022] [Indexed: 02/03/2023] Open
Abstract
The hepatic diseases are extremely common in clinical practice. The correct classification of liver fibrosis is extremely important, as it influences therapy and predicts disease outcomes. The purpose of this study is to compare the diagnostic performance of point-shear wave elastography (pSWE) and magnetic resonance elastography (MRE) in the hepatic fibrosis diagnostic. A meta-analysis was carried out based on articles published until October 2020. The articles are available at following databases: MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials, Scientific Electronic Library Online, LILACS, Scopus, and CINAHL. Diagnostic performances were analyzed per METAVIR F2, using 3.5kPa as target fibrosis. Assessment of the methodological quality of the incorporated papers by the QUADAS-2 tool for pSWE and MRE. A total 2,153 studies articles were evaluated and 44 studies, comprising 6,081 patients with individual data, were included in the meta-analysis: 28 studies for pSWE and 16 studies for MRE. The pooled sensitivity and specificity were 0.86 (95%CI 0.80-0.90) and 0.88 (95%CI 0.85-0.91), respectively, for pSWE, compared with 0.94 (95%CI 0.89-0.97) and 0.95 (95%CI 0.89-0.98) respectively, for MRE. The pooled SROC curve for pSWE shows in the area under the curve (AUC) of 0.93 (95%CI 0.90-0.95), whereas the AUC for MRE was 0.98 (95%CI 0.96-0.99). The diagnostic odds ratio for pSWE and MRE were 41 (95%CI 24-72) and 293 (95%CI 86-1000), respectively. There was statistically significant heterogeneity for pSWE sensitivity (I² = 85.26, P<0.001) and specificity (I² = 89.46, P<0.001). The heterogeneity for MRE also was significant for sensitivity (I² = 73.28, P<0.001) and specificity (I² = 87.24, P<0.001). Therefore, both pSWE and MRE are suitable modalities for assessing liver fibrosis. In addition, MRE is a more accurate imaging technique than pSWE and can be used as alternative to invasive biopsy.
Collapse
Affiliation(s)
- João Paulo L. Schambeck
- Post-Graduate Program in Medicine and Health Science, Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil
- Departament of Radiology, Hospital São Lucas/Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil
| | - Gabriele C. Forte
- Departament of Radiology, Hospital São Lucas/Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil
- Faculty of Medicine, Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil
- * E-mail:
| | - Luana M. Gonçalves
- Post-Graduate Program in Medicine and Health Science, Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil
- Departament of Radiology, Hospital São Lucas/Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil
| | - Guilherme Stuker
- Departament of Radiology, Hospital São Lucas/Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil
| | - João Bruno F. Kotlinski
- Faculty of Medicine, Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil
| | - Giacomo Tramontin
- Departament of Radiology, Hospital São Lucas/Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil
| | - Stephan Altmayer
- Post-Graduate Program in Medicine and Health Science, Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil
| | - Guilherme Watte
- Department of Radiology, Medical Imaging Research Lab, LABIMED, Porto Alegre, Rio Grande do Sul, Brazil
| | - Bruno Hochhegger
- Post-Graduate Program in Medicine and Health Science, Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil
- Departament of Radiology, Hospital São Lucas/Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil
- Department of Radiology, Medical Imaging Research Lab, LABIMED, Porto Alegre, Rio Grande do Sul, Brazil
- Department of Diagnostic Methods, Federal University of Health Sciences of Porto Alegre, Porto Alegre, Rio Grande do Sul, Brazil
| |
Collapse
|
4
|
Dong B, Lyu G, Chen Y, Lin G, Wang H, Qin R, Gu J. Comparison of two-dimensional shear wave elastography, magnetic resonance elastography, and three serum markers for diagnosing fibrosis in patients with chronic hepatitis B: a meta-analysis. Expert Rev Gastroenterol Hepatol 2021; 15:1077-1089. [PMID: 33487039 DOI: 10.1080/17474124.2021.1880894] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
BACKGROUND Two-dimensional shear wave elastography (2D-SWE), magnetic resonance elastography (MRE), aspartate transaminase-to-platelet ratio index (APRI), fibrosis index based on 4 factors (FIB-4), and King's score have been proposed for diagnosing fibrosis. METHODS Literature databases were searched until October 1st, 2020. The summary area under the receiver operating characteristic curve (AUROC), the summary diagnostic odds ratios, and the summary sensitivities and specificities were used to assess the performance of these noninvasive methods for staging fibrosis. RESULTS Our final data contained 72 studies. The prevalence of significant fibrosis, advanced fibrosis, and cirrhosis was 58.3%, 36.2%, and 20.5%, respectively, in chronic hepatitis B (CHB). For 2D-SWE and MRE, the summary AUROCs were 0.89 and 0.97, 0.95 and 0.97, and 0.94 and 0.97 for significant fibrosis, advanced fibrosis, and cirrhosis, respectively. The summary AUROCs using APRI and FIB-4 for detecting significant fibrosis, advanced fibrosis, and cirrhosis were 0.76 and 0.75, 0.74 and 0.77, and 0.77 and 0.82, respectively. The summary AUROCs of King's score for detecting significant fibrosis and cirrhosis were 0.77 and 0.83, respectively. CONCLUSION MRE and 2D-SWE may show the best diagnostic accuracy for predicting fibrosis in CHB. Among the three serum markers, King's score may be more useful for diagnosing fibrosis.
Collapse
Affiliation(s)
- Bingtian Dong
- Department of Ultrasound, The Second Affiliated Hospital of Fujian Medical University, Quanzhou, Fujian Province, China
| | - Guorong Lyu
- Department of Ultrasound, The Second Affiliated Hospital of Fujian Medical University, Quanzhou, Fujian Province, China.,Department of Clinical Medicine, Quanzhou Medical College, Quanzhou, Fujian Province, China
| | - Yuping Chen
- Department of Endocrinology, The Second Affiliated Hospital of Fujian Medical University, Quanzhou, Fujian Province, China
| | - Guofu Lin
- Department of Pulmonary and Critical Care Medicine, The Second Affiliated Hospital of Fujian Medical University, Respirology Medicine Centre of Fujian Province, Quanzhou, Fujian Province, China
| | - Huaming Wang
- Department of Ultrasound, The Second Affiliated Hospital of Fujian Medical University, Quanzhou, Fujian Province, China
| | - Ran Qin
- Department of Ultrasound, The Chenggong Hospital, Xiamen University, Xiamen, Fujian Province, China
| | - Jionghui Gu
- Department of Ultrasound, the First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, Zhejiang Province, China
| |
Collapse
|
5
|
Mercedes R, Brown J, Minard C, Tsai CM, Devaraj S, Munden M, Leung D. A Liver Biopsy Validation Pilot Study of Shear Wave Elastography, APRI, FIB-4, and Novel Serum Biomarkers for Liver Fibrosis Staging in Children With Chronic Viral Hepatitis. Glob Pediatr Health 2020; 7:2333794X20938931. [PMID: 32821773 PMCID: PMC7412911 DOI: 10.1177/2333794x20938931] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2020] [Revised: 03/12/2020] [Accepted: 05/26/2020] [Indexed: 01/04/2023] Open
Abstract
As liver biopsy in children poses inherent risks, noninvasive measures of liver fibrosis are needed. This was a cross-sectional, liver biopsy validation pilot study of 16 participants evaluating the ability of shear wave elastography, aspartate transaminase to platelet ratio index (APRI), fibrosis index based on the 4 factors, and novel serum biomarkers to stage liver fibrosis in children with chronic hepatitis B or C. There was very high intrasegmental shear wave speed variation in our participants and little correlation with fibrosis. APRI and monocyte chemoattractant protein (MCP-1) were higher in fibrosis stage F2-3 versus F0-1 (P = .02, P = .06, respectively). Soluble Fas (sFas) was lower in F2-3 versus F0-1 (P = .046). A logistic regression analysis calculated by (APRI × MCP-1)/sFas demonstrated an area under the receiver operating characteristic curve of 0.92 (P < .001), suggesting that this combination can differentiate fibrosis stage F0-1 from F2-3 in children with chronic viral hepatitis.
Collapse
Affiliation(s)
| | | | | | - Cynthia M Tsai
- Baylor College of Medicine, Houston, TX, USA.,Texas Children's Hospital, Houston, TX, USA
| | | | - Marthe Munden
- Wake Forest Baptist Medical Center, Winston-Salem, NC, USA
| | - Daniel Leung
- Baylor College of Medicine, Houston, TX, USA.,Texas Children's Hospital, Houston, TX, USA
| |
Collapse
|
6
|
Xu XY, Wang WS, Zhang QM, Li JL, Sun JB, Qin TT, Liu HB. Performance of common imaging techniques vs serum biomarkers in assessing fibrosis in patients with chronic hepatitis B: A systematic review and meta-analysis. World J Clin Cases 2019; 7:2022-2037. [PMID: 31423434 PMCID: PMC6695542 DOI: 10.12998/wjcc.v7.i15.2022] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/02/2019] [Revised: 06/25/2019] [Accepted: 07/03/2019] [Indexed: 02/05/2023] Open
Abstract
BACKGROUND Noninvasive biomarkers have been developed to predict hepatitis B virus (HBV) related fibrosis owing to the significant limitations of liver biopsy. Both serum biomarkers and imaging techniques have shown promising results and may improve the evaluation of liver fibrosis. However, most of the previous studies focused on the diagnostic effects of various imaging techniques on fibrosis in all chronic liver diseases.
AIM To compare the performance of common imaging methods and serum biomarkers for prediction of significant fibrosis caused only by HBV infection.
METHODS A systematic review was conducted on the records available in PubMed, EMBASE, and the Cochrane Library electronic databases until December 2018. We systematically assessed the effectiveness of two serum biomarkers and three imagine techniques in predicting significant fibrosis solely caused by HBV infection. The serum biomarkers included aspartate aminotransferase-to-platelet ratio index (APRI) and fibrosis index based on the 4 factors (FIB-4). The three imaging techniques included acoustic radiation force impulse (ARFI), FibroScan, and magnetic resonance elastography (MRE). Three parameters, the area under the summary receiver operating characteristic curve (AUSROC), the summary diagnostic odds ratio, and the summary sensitivity and specificity, were used to examine the accuracy of all tests for liver fibrosis.
RESULTS Out of 2831 articles evaluated for eligibility, 204 satisfied the predetermined inclusion criteria for this current meta-analysis. Eventually, our final data contained 81 studies. The AUSROCs of serum biomarkers of APRI and FIB-4 were both 0.75. For imaging techniques (ARFI, FibroScan, and MRE), the areas were 0.89, 0.83, and 0.97, respectively. The heterogeneities of ARFI and FibroScan were statistically significant (I2 > 50%). The publication bias was not observed in any of the serum biomarkers or imaging methods.
CONCLUSION These five methods have attained an acceptable level of diagnostic accuracy. Imaging techniques, MRE in particular, demonstrate significant advantages in accurately predicting HBV-related significant fibrosis, while serum biomarkers are admissible methods.
Collapse
Affiliation(s)
- Xue-Ying Xu
- Department of Epidemiology and Health Statistics, School of Public Health, China Medical University, Shenyang 110122, Liaoning Province, China
| | - Wu-Sheng Wang
- Department of Epidemiology and Health Statistics, School of Public Health, China Medical University, Shenyang 110122, Liaoning Province, China
| | - Qi-Meng Zhang
- Department of Epidemiology and Health Statistics, School of Public Health, China Medical University, Shenyang 110122, Liaoning Province, China
| | - Jun-Ling Li
- Department of Epidemiology and Health Statistics, School of Public Health, China Medical University, Shenyang 110122, Liaoning Province, China
| | - Jin-Bin Sun
- Department of Epidemiology and Health Statistics, School of Public Health, China Medical University, Shenyang 110122, Liaoning Province, China
| | - Tian-Tian Qin
- Department of Epidemiology and Health Statistics, School of Public Health, China Medical University, Shenyang 110122, Liaoning Province, China
| | - Hong-Bo Liu
- Department of Epidemiology and Health Statistics, School of Public Health, China Medical University, Shenyang 110122, Liaoning Province, China
| |
Collapse
|
7
|
Park HS, Choe WH, Han HS, Yu MH, Kim YJ, Jung SI, Kim JH, Kwon SY. Assessing significant fibrosis using imaging-based elastography in chronic hepatitis B patients: Pilot study. World J Gastroenterol 2019; 25:3256-3267. [PMID: 31333316 PMCID: PMC6626721 DOI: 10.3748/wjg.v25.i25.3256] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/19/2019] [Revised: 05/20/2019] [Accepted: 06/08/2019] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND Accurate detection of significant fibrosis (fibrosis stage 2 or higher on the METAVIR scale) is important especially for chronic hepatitis B (CHB) patients with high viral loads but with normal or mildly elevated alanine aminotransferase (ALT) levels because the presence of significant fibrosis is accepted as the indication for antiviral treatment. Liver biopsy is the reference standard for diagnosing significant fibrosis, but it is an invasive procedure. Consequently, noninvasive imaging-based measurements, such as magnetic resonance elastography (MRE) or two-dimensional shear-wave elastography (2D-SWE), have been proposed for the quantitative assessment of liver fibrosis.
AIM To explore MRE and 2D-SWE to identify fibrosis stage, and to compare their performance with that of serum-based indices.
METHODS The study enrolled 63 treatment-naïve CHB patients with high viral loads but with normal or mildly elevated ALT levels who underwent liver biopsy before a decision was made to initiate antiviral therapy. MRE and 2D-SWE were performed, and serum-based indices, such as FIB-4 and aspartate transaminase to platelet ratio index (APRI), were calculated. The diagnostic performances of MRE, 2D-SWE, FIB-4, and APRI for assessing significant fibrosis (≥ F2) and cirrhosis (F4) were evaluated with liver histology as the reference standard, using receiver operating characteristic analyses.
RESULTS The liver fibrosis stage was F0/F1 in 19, F2 in 14, F3 in 14, and F4 in 16 patients, respectively. MRE significantly discriminated F2 from F0/1 (P = 0.022), whereas 2D-SWE showed a broad overlap in distinguishing those stages. MRE showed a higher correlation coefficient value with fibrosis stage than 2D-SWE with fibrosis stage (0.869 vs 0.649, Spearman test; P < 0.001). Multivariate linear regression analyses showed that fibrosis stage was the only factor affecting the values of MRE (P < 0.001), whereas body mass index (P = 0.042) and fibrosis stage (P < 0.001) were independent factors affecting 2D-SWE values. MRE performance for diagnosing significant fibrosis was better [area under the curve (AUC) = 0.906, positive predictive value (PPV) 97.3%, negative predictive value (NPV) 69.2%] than that of FIB-4 (AUC = 0.697, P = 0.002) and APRI (AUC = 0.717, P = 0.010), whereas the performance of 2D-SWE (AUC = 0.843, PPV 86%, NPV 65%) was not significantly different from that of FIB-4 or APRI.
CONCLUSION Compared to SWE, MRE might be more precise non-invasive assessment for depicting significant fibrosis and for making-decision to initiate antiviral-therapy in treatment-naïve CHB patients with normal or mildly-elevated ALT levels.
Collapse
Affiliation(s)
- Hee Sun Park
- Department of Radiology, Konkuk University School of Medicine, Seoul 05030, South Korea
| | - Won Hyeok Choe
- Department of Internal Medicine, Konkuk University School of Medicine, Seoul 05030, South Korea
| | - Hye Seung Han
- Department of Pathology, Konkuk University School of Medicine, Seoul 05030, South Korea
| | - Mi Hye Yu
- Department of Radiology, Konkuk University School of Medicine, Seoul 05030, South Korea
| | - Young Jun Kim
- Department of Radiology, Konkuk University School of Medicine, Seoul 05030, South Korea
| | - Sung Il Jung
- Department of Radiology, Konkuk University School of Medicine, Seoul 05030, South Korea
| | - Jeong Han Kim
- Department of Internal Medicine, Konkuk University School of Medicine, Seoul 05030, South Korea
| | - So Young Kwon
- Department of Internal Medicine, Konkuk University School of Medicine, Seoul 05030, South Korea
| |
Collapse
|