1
|
Xiao Y, Chen W, Long X, Li M, Zhang L, Liu C, Deng Y, Li C, He B, Chen J, Wang J. 3D MR elastography-based stiffness as a marker for predicting tumor grade and subtype in cervical cancer. Magn Reson Imaging 2024; 109:173-179. [PMID: 38484948 DOI: 10.1016/j.mri.2024.03.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2023] [Revised: 03/05/2024] [Accepted: 03/05/2024] [Indexed: 03/25/2024]
Abstract
BACKGROUND Increasing evidence has indicated that high tissue stiffness (TS) may be a potential biomarker for evaluation of tumor aggressiveness. PURPOSE To investigate the value of magnetic resonance elastography (MRE)-based quantitative parameters preoperatively predicting the tumor grade and subtype of cervical cancer (CC). STUDY TYPE Retrospective. POPULATION Twenty-five histopathology-proven CC patients and 7 healthy participants. FIELD STRENGTH/SEQUENCE 3.0T, magnetic resonance imaging (MRI) (LAVA-flex) and MRE with a three-dimensional spin-echo echo-planar imaging. ASSESSMENT The regions of interest (ROIs) were manually drawn by two observers in tumors to measure mean TS, storage modulus (G'), loss modulus (G″) and damping ratio (DR) values. Surgical specimens were evaluated for tumor grades and subtypes. STATISTICAL TESTS Intraclass correlation coefficient (ICC) was expressed in terms of inter-observer agreements. t-test or Mann-Whitney nonparametric test was used to compare the complex modulus and apparent diffusion coefficient (ADC) values between different tumor groups. Area under the receiver operating characteristic curve (AUC) analysis was used to evaluate the diagnostic performance. RESULTS The TS of endocervical adenocarcinoma (ECA) group was significantly higher than that in squamous cell carcinoma (SCC) group (5.27 kPa vs. 3.44 kPa, P = 0.042). The TS also showed significant difference between poorly and well/moderately differentiated CC (5.21 kPa vs. 3.47 kPa, P = 0.038), CC patients and healthy participants (4.18 kPa vs. 1.99 kPa, P < 0.001). The cutoff value of TS to discriminate ECA from SCC was 4.10 kPa (AUC: 0.80), while it was 4.42 kPa to discriminate poorly from well/moderately differentiated CC (AUC: 0.83), and 2.25 kPa to distinguish normal cervix from CC (AUC: 0.88), respectively. There were no significant difference in G″, DR and ADC values between any subgroups except for comparison of healthy participants and CC patients (P = 0.001, P = 0.004, P < 0.001, respectively). DATA CONCLUSION 3D MRE-assessed TS shows promise as a potential biomarker to preoperatively assess tumor grade and subtype of CC.
Collapse
Affiliation(s)
- Yuanqiang Xiao
- Department of Radiology, Third Affiliated Hospital of Sun Yat-sen University (SYSU), Guangzhou, Guangdong 510630, China.
| | - Wenying Chen
- Department of Radiology, Third Affiliated Hospital of Sun Yat-sen University (SYSU), Guangzhou, Guangdong 510630, China.
| | - Xi Long
- Department of Radiology, Meizhou People's Hospital (Huangtang Hospital), Meizhou 51403, China.
| | - Mengsi Li
- Department of Radiology, Third Affiliated Hospital of Sun Yat-sen University (SYSU), Guangzhou, Guangdong 510630, China.
| | - Lina Zhang
- Department of Radiology, Third Affiliated Hospital of Sun Yat-sen University (SYSU), Guangzhou, Guangdong 510630, China.
| | - Chang Liu
- Department of Radiology, Third Affiliated Hospital of Sun Yat-sen University (SYSU), Guangzhou, Guangdong 510630, China.
| | - Ying Deng
- Department of Radiology, Third Affiliated Hospital of Sun Yat-sen University (SYSU), Guangzhou, Guangdong 510630, China.
| | - Chao Li
- Department of Radiology, Third Affiliated Hospital of Sun Yat-sen University (SYSU), Guangzhou, Guangdong 510630, China.
| | - Bingjun He
- Department of Radiology, Third Affiliated Hospital of Sun Yat-sen University (SYSU), Guangzhou, Guangdong 510630, China.
| | - Jun Chen
- Department of Radiology, Mayo Clinic College of Medicine, Mayo Clinic, 200 First Street SW, Rochester, MN 55905, USA.
| | - Jin Wang
- Department of Radiology, Third Affiliated Hospital of Sun Yat-sen University (SYSU), Guangzhou, Guangdong 510630, China.
| |
Collapse
|
2
|
Ma Y, Zhao X, Chen X. Contrast-enhanced ultrasound combined with elastic imaging for predicting the efficacy of concurrent chemoradiotherapy in cervical cancer: a feasibility study. Front Oncol 2024; 14:1301900. [PMID: 38634056 PMCID: PMC11021703 DOI: 10.3389/fonc.2024.1301900] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Accepted: 03/18/2024] [Indexed: 04/19/2024] Open
Abstract
Objective Contrast-enhanced ultrasound (CEUS) and elastography are of great value in the diagnosis of cervical cancer (CC). However, there is limited research on the role of contrast-enhanced ultrasound combined with elastography in predicting concurrent chemoradiotherapy and disease progression for cervical cancer. The purpose of this study was to evaluate the feasibility of contrast-enhanced ultrasound combined with elastography and tumor prognosis. Methods MRI was performed on 98 patients with cervical cancer before and after treatment. Before, during, and 1 week after the treatment, contrast-enhanced ultrasound and elastography were conducted, and the alterations of ultrasound-related parameters at each time point of the treatment were compared. The correlation between contrast-enhanced ultrasound combined with elastic imaging and oncological outcome was assessed. Results There was no notable difference in overall clinical data between the complete remission (CR) group and the partial remission (PR) group (P>0.05). Before treatment, there were no statistically significant differences in elasticity score, time to peak (TTP), and peak intensity (PI) between the CR group and the PR group. However, there were no statistical differences in elastic strain ratio (SR) and area under the curve (AUC) before and after treatment between the CR group and the PR group, and there were also no statistical differences in the elastic strain ratio (SR) and area under the curve (AUC) of contrast-enhanced ultrasound parameters between the CR group and the PR group before and during treatment. There was a statistically significant difference after treatment (P<0.05).At present, the follow-up of patients is about 1 year, 7 patients were excluded due to loss to follow-up, and 91 patients were included in the follow-up study. Through the review of the cases and combined with MRI (version RECIST1.1) and serology and other related examinations, if the patient has a new lesion or the lesion is larger than before, the tumor marker Squamous cell carcinoma antigen (SCC-Ag) is significantly increased twice in a row, and the patient is divided into progressive disease (PD). Those who did not see significant changes were divided into stable disease (SD) group. The relationship between clinical characteristics, ultrasound parameters and disease progression in 91 patients was compared. There was no significant difference in age and clinical stage between the two groups (P>0.05), but there was a significant difference in the elevation of tumor marker squamous cell carcinoma antigen (SCC-Ag) between the two groups (P<0.05).With the growth of tumors, TTP decreased, elasticity score and PI increased, and the difference was statistically significant (P<0.05). The AUC of SCC-Ag was 0.655, the sensitivity was 85.3%, and the specificity was 45.6%.The AUC, sensitivity and specificity of ultrasound parameters combined with SCC-Ag predicted disease progression was 0.959, 91.2% and 94.8%. Conclusions Using contrast-enhanced ultrasound and elastography to predict the efficacy and disease progression of concurrent chemoradiotherapy is feasible. In addition, the combination of SCC-Ag with contrast-enhanced ultrasound and elastography can further enhance the efficiency of predicting disease progression.
Collapse
Affiliation(s)
- Yujuan Ma
- Tianshui Maternity and Child Healthcare Hospital, Tianshui, China
| | - Xuebo Zhao
- Graduate School of Qinghai University, Xining, China
- Department of Ultrasound Medicine, Qinghai Provincial People’s Hospital, Xining, China
| | - Xianxia Chen
- Department of Ultrasound Medicine, Qinghai Provincial People’s Hospital, Xining, China
| |
Collapse
|
3
|
Yücel E, Koca Yıldırım HE, Şahin Duran F, Çakır C, Korkmaz V. The role of cervical elastography in the differential diagnosis of preinvasive and invasive lesions of the cervix. Arch Gynecol Obstet 2024; 309:1585-1595. [PMID: 38282023 DOI: 10.1007/s00404-023-07345-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2023] [Accepted: 12/05/2023] [Indexed: 01/30/2024]
Abstract
STUDY OBJECTIVE This study aims to evaluate the role of cervical elastography in the differential diagnosis of preinvasive and invasive lesions of the cervix. MATERIALS AND METHODS A total of 95 women participated in this prospective study and were divided into the following groups: 19 healthy subjects (group 1) with normal cervicovaginal smear (CVS) and negative human papillomavirus test (HPV DNA), 19 women with normal cervical biopsy and normal final pathological result of cervical biopsy (group 2), 19 women with low-grade squamous intraepithelial lesion (LSIL) (group 3), 19 women with high-grade squamous intraepithelial lesion (HSIL) (group 4), and 19 women with cervical cancer (group 5). Clinical, demographic, histopathological, and elastographic results were compared between these groups. RESULTS Comparing groups, age (40.42 ± 8.31 vs. 39.53 ± 8.96 vs. 38.79 ± 9.53 vs. 40.74 ± 7.42 vs. 54.63 ± 12.93, p < 0.001 respectively), gravida (1.74 ± 1.33 vs. 2.16 ± 1.68 vs. 2.21 ± 1.96 vs. 2.53 ± 1.93 vs. 4.63 ± 2.17 p < 0.001 respectively), parity (1.37 ± 0.68 vs. 1.68 ± 1.20 vs. 1.58 ± 1.30 vs. 2.00 ± 1.67 vs. 3.37 ± 1.61, p < 0.001 respectively), and the proportion of patients at menopause (10.5% vs., 15.8% vs. 10.5% vs. 5.3% vs. 57.9%, p < 0.01 respectively), a statistically significant difference was found (Table 1). However, no statistically significant difference was found in the number of abortions, BMI, mode of delivery, smoking, additional disease status, history of surgery, and family history (p > 0.05) (Table 2. As a result of the applied roc analysis, mean cervical elastographic stiffness degree (ESD) was found to be an influential factor in predicting cervical cancer (p < 0.05). The mean cut-off value was 44.65%, with a sensitivity of 94.7% and a specificity of 96.1% (Table 7). CONCLUSION Measurement of ESD by elastography is a low-cost, easily applicable, and non-invasive indicator that can distinguish cervical cancer from normal cervical and preinvasive lesions. However, it is unsuitable for determining preinvasive cervical lesions from normal cervix.
Collapse
Affiliation(s)
- Ecem Yücel
- Niğde Ömer Halis Demir Training and Research Hospital, Niğde, Turkey
| | - Hande Esra Koca Yıldırım
- Department of Gynecologic Oncology, Faculty of Medicine, Ankara Etlik City Hospital, University of Health Sciences, Ankara, Turkey.
| | - Firdevs Şahin Duran
- Department of Pathology, Faculty of Medicine, Ankara Etlik City Hospital, University of Health Sciences, Ankara, Turkey
| | - Caner Çakır
- Department of Gynecologic Oncology, Faculty of Medicine, Ankara Etlik City Hospital, University of Health Sciences, Ankara, Turkey
| | - Vakkas Korkmaz
- Department of Gynecologic Oncology, Faculty of Medicine, Ankara Etlik City Hospital, University of Health Sciences, Ankara, Turkey
| |
Collapse
|
4
|
Sun H, Lv Q, Liu T, Zhang N, Shi F. Diagnostic accuracy of cervical elastography for predicting preterm delivery: Systematic review and meta-analysis. Scott Med J 2023; 68:110-120. [PMID: 37259580 DOI: 10.1177/00369330231178910] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
OBJECTIVE Cervical elastography has been used in pregnant women to diagnose preterm births. However, there is a variability in the measured elasticity parameters and imaging mode used. We evaluated the precision of cervical elastography in identifying preterm births. METHODS Extensive and methodical searches were made in the databases such as Scopus, Embase, Cochrane Library, PubMed Central, Medline, ScienceDirect, and Google Scholar from the inception until November 2022, for studies that report diagnostic accuracy of cervical elastography for preterm deliveries in antenatal women. RESULTS The pooled sensitivity and specificity value of cervical elastography for preterm deliveries were 82% (95%CI: 73%-89%) and 77% (95%CI: 64%-86%), respectively with area under curve (AUC) of 0.87 (95%CI: 0.72-0.95). The diagnostic odds ratio (DOR) was 15 (95%CI: 8-28), positive likelihood ratio (LRP) was 3.5 (95%CI: 2.3-5.5) and negative likelihood ratio LRN was 0.23 (0.16-0.34). Pooled sensitivity and specificity of shear wave elastography was 88% and 71%, respectively. Pooled sensitivity and specificity of strain elastography was 80% and 79%, respectively. Heterogeneity was significant, as indicated by chi-square test and an I2 statistic of over 75. CONCLUSIONS Cervical elastography can be used for predicting preterm deliveries with moderate to high level of accuracy.
Collapse
Affiliation(s)
- Hui Sun
- Department of Special Inspection, Qingdao Women and Children's Hospital, Qingdao City, Shandong Province, China
| | - Qifeng Lv
- Department of Cardiac Ultrasound, Affiliated Hospital of Qingdao University, Qingdao City, Shandong Province, China
| | - Tingting Liu
- Department of Ultrasound, Weifang People's Hospital, Weifang City, Shandong Province, China
| | - Nan Zhang
- Department of Ultrasound, Affiliated Hospital of Qingdao University, Qingdao City, Shandong Province, China
| | - Fengfeng Shi
- Department of Abdominal Ultrasound, Affiliated Hospital of Qingdao University, Qingdao City, Shandong Province, China
| |
Collapse
|
5
|
Ong C, Chew L, Han NL, Ooi C, Yeo Y, Chew S, Wong W, Tang P, Teo S. The characteristics of real-time transvaginal sono-elastography in endometrial cancer. J Med Ultrasound 2022; 30:101-108. [PMID: 35832355 PMCID: PMC9272722 DOI: 10.4103/jmu.jmu_74_21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2021] [Revised: 06/15/2021] [Accepted: 07/20/2021] [Indexed: 11/28/2022] Open
Abstract
Background: Endometrial cancer is the most common gynecological cancer among women in developed countries. Sono-elastography is an extended ultrasonographic technique that has been shown to be useful in a wide range of conditions ranging from breast, prostate, and thyroid nodules to chronic liver disease and musculoskeletal conditions. The aim of this study is to compare the sonoelastographic features of endometrial malignancy and normal endometrium. Methods: This case–control observational study was conducted at a single institution. Participants with histologically proven endometrial cancer according to the results from microcurettage or hysteroscopic biopsy and scheduled for total hysterectomy were included as cases, while asymptomatic women scheduled for routine screening ultrasound examination were recruited as controls. Both cases and controls underwent conventional B-mode transvaginal ultrasonography and strain elastography. Demographic, ultrasonographic, and histopathologic findings were analyzed. Results: A total of 29 endometrial cancer patients (cases) and 28 normal females (controls) were included in the analysis. There was no significant difference in the mean age between the two groups, but the mean body weight was significantly higher in the case group (P < 0.001). The strain ratio and elastographic thickness ratio of the endometrium were statistically significantly different between the case and the control group (P ≤ 0.05) due to increased endometrial stiffness in cancer patients as compared to the normal group. Conclusion: Our results suggest that endometrial cancer can result in increased stiffness that is detectable by transvaginal sonoelastography. Sonoelastography may serve as an adjunct to conventional ultrasound in evaluating the endometrium of women with abnormal uterine bleeding.
Collapse
|
6
|
Sainz JA, Castro L, Romo JM, Holgado A, Fernández-Palacín A, García-Mejido JA. Evaluation of Pre-malignant Lesions of the Uterine Cervix by Shear Wave Elastography: A New Diagnostic Tool. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:3275-3282. [PMID: 34376298 DOI: 10.1016/j.ultrasmedbio.2021.06.021] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/01/2021] [Revised: 06/26/2021] [Accepted: 06/30/2021] [Indexed: 06/13/2023]
Abstract
The objective of the study was to evaluate the difference in the stiffness between a healthy cervix (no pre-invasive lesions [NPILs]) and a cervix with a pre-invasive lesion (PIL). In the PIL group, we determined whether there was a difference in stiffness between the cervix with persistent low-grade lesions (>2 y, LSIL-persistent) and that with high-grade lesions (HSILs). Evaluation was performed using 2-D shear-wave elastography (SWE) in the midsagittal-plane of the uterine cervix (UC) at 0.5 cm (cervical canal, anterior and posterior cervical lips). In this prospective observational study (consecutive series), we evaluated 96 non-pregnant women: a group with PIL (LSIL-persistent, 22 cases; HSIL, 26 cases) with indications for cervical conization (48 cases) and a group without UC pathology (NPIL, 48 cases). Although we did not observe statistically significant differences (SSDs) in epidemiological characteristics, we did find an SSD in the speed and stiffness between the PIL versus NPIL groups at all evaluated depths (speed: 4.1 m/s vs 3.0 m/s, stiffness: 58.6 and 34.5kPa in the PIL and NPIL groups, respectively, p < 0.001). An SSD in speed and stiffness (speed: 4.9 m/s vs. 3.2 m/s, and stiffness: 76.1 and 38.0 kPa) between the HSIL (26 cases) and LSIL-persistent (22 cases) groups, respectively, was also detected (p < 0.001). The area under the curve of speed differentiation between a cervix with HSILs and without lesions was 73.4% (95% confidence interval [CI]: 63.1-83.7), and the best cutoff of speed was 3.25 m/s (sensitivity = 62.5%, 95% CI: 47.3-76.0), with a specificity of 75.5% (95% CI: 60.4-87.1).
Collapse
Affiliation(s)
- José Antonio Sainz
- Department of Obstetrics and Gynecology, Valme University Hospital, Seville, Spain; Department of Obstetrics and Gynecology, University of Seville, Seville, Spain.
| | - Laura Castro
- Department of Obstetrics and Gynecology, Valme University Hospital, Seville, Spain
| | - José María Romo
- Department of Obstetrics and Gynecology, Valme University Hospital, Seville, Spain
| | - Ainhoa Holgado
- Department of Obstetrics and Gynecology, Valme University Hospital, Seville, Spain
| | - Ana Fernández-Palacín
- Biostatistics Unit, Department of Preventive Medicine and Public Health, University of Seville, Seville, Spain
| | - José Antonio García-Mejido
- Department of Obstetrics and Gynecology, Valme University Hospital, Seville, Spain; Department of Obstetrics and Gynecology, University of Seville, Seville, Spain
| |
Collapse
|
7
|
Shao J, Shi G, Qi Z, Zheng J, Chen S. Advancements in the Application of Ultrasound Elastography in the Cervix. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:2048-2063. [PMID: 34049726 DOI: 10.1016/j.ultrasmedbio.2021.04.009] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Revised: 04/01/2021] [Accepted: 04/10/2021] [Indexed: 06/12/2023]
Abstract
Ultrasound elastography is a modern imaging technique that has developed rapidly in recent years. It enables objective measurement of tissue stiffness, a physical property intuitive to the human sense of touch. This novel technology has become a hotspot and plays a major role in scientific research and academic practice. Presently, ultrasound elastography has been used in the identification of benign and malignant tumors in superficial organs, such as breast and thyroid, providing clinically accurate diagnosis and treatment. The method has also been widely used for the liver, kidney, prostate, lymph nodes, blood vessels, skin and muscle system. In the application of cervical lesions, ultrasound elastography can distinguish normal cervix from abnormal cervix and differentiate benign from malignant lesions. It can significantly improve the diagnostic specificity for cervical cancer and is also useful for assessing infiltration depth and stage of cervical cancer, as well as predicting chemoradiotherapy treatment response. For cervical evaluation during pregnancy, ultrasound elastography is useful for assessing cervical softening and predicting premature delivery and outcome of induced labor. This article reviews the principles of ultrasound elastography as well as the current status and limitations in its application for cervical lesions and the cervix during pregnancy.
Collapse
Affiliation(s)
- Juntao Shao
- Department of Ultrasound, The First Hospital of Qinhuangdao, Qinhuangdao, Hebei Province, China.
| | - Guilian Shi
- School of Biomedical Engineering, Hubei University of Science and Technology, Xianning, Hubei Province, China
| | - Zhengqin Qi
- Department of Ultrasound, The First Hospital of Qinhuangdao, Qinhuangdao, Hebei Province, China
| | - Jingjing Zheng
- Department of Ultrasound, The First Hospital of Qinhuangdao, Qinhuangdao, Hebei Province, China
| | - Shigao Chen
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA
| |
Collapse
|
8
|
Oh H, Park SB, Park HJ, Lee ES, Hur J, Choi W, Choi BI. Ultrasonographic features of uterine cervical lesions. Br J Radiol 2021; 94:20201242. [PMID: 33560888 DOI: 10.1259/bjr.20201242] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
Currently, ultrasound (US) is a valuable imaging tool for the initial assessment and evaluation of the female genital organs, uterus, and adnexa. However, it is easy to overlook the uterine cervix while conducting a pelvic US. Uterine cervical lesions may range from benign to malignant in nature. Therefore, meticulous examination with US may play a key role in assessing uterine cervical lesions. Although there is substantial overlap in the US findings across various uterine cervical lesions, some US features, in tandem with clinical characteristics, may suggest a specific diagnosis. Familiarity with the clinical settings and US characteristics of different uterine cervical lesions can support prompt and accurate diagnosis of suspicious lesions. This review article aims to describe the features of US and possible values for distinction of these lesions in the uterine cervix.
Collapse
Affiliation(s)
- Hyunji Oh
- Department of Radiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul, South Korea
| | - Sung Bin Park
- Department of Radiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul, South Korea
| | - Hyun Jeong Park
- Department of Radiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul, South Korea
| | - Eun Sun Lee
- Department of Radiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul, South Korea
| | - Joonho Hur
- Department of Radiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul, South Korea
| | - Woosun Choi
- Department of Radiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul, South Korea
| | - Byung Ihn Choi
- Department of Radiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul, South Korea
| |
Collapse
|
9
|
Elastography of Endometrium in Women Taking Tamoxifen: A New Approach to an Old Diagnostic Problem. J Clin Med 2020; 9:jcm9123870. [PMID: 33260709 PMCID: PMC7760647 DOI: 10.3390/jcm9123870] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2020] [Revised: 11/14/2020] [Accepted: 11/25/2020] [Indexed: 11/17/2022] Open
Abstract
Tamoxifen is a commonly used selective estrogen receptor modulator applied in the treatment for breast cancer. However, in the endometrium, Tamoxifen stimulates tissue growth, cellular transformation, the migration of the cells, and metastatic potential in endometrial cancer. Considering that uterine cancer is the most common neoplasm of the reproductive tract and the third most common neoplastic disease in women, the aim of this study was to investigate if applying elastography in examining the endometrium was beneficial for uterine cancer screening protocols in women on selective estrogen receptor modulator therapy. This study was based on the execution of a classic assessment of the endometrium that included the evaluation of the following: echogenicity, central endometrial stripe, presence of fluid in the uterine lumen, myometrium–endometrium interface, intensity of vascularization and vascular pattern. An ultrasound presentation was then processed and analyzed with elastography. The values of the elastography parameters demonstrated good consistency for the measurement of the softest endometrial layer thickness in elastography. A strong positive correlation (R = 0.56) was demonstrated between the endometrial thickness, as determined by ultrasound examination, and the softest endometrial layer in elastography (p < 0.001). The research showed that the elastography measurements of the width of the softest endometrium layer, based on a population of women taking Tamoxifen, appeared to be a promising option for endometrial cancer screening.
Collapse
|
10
|
Zhu Y, Leng XF, Zhang GN, Huang ZY, Qiu L, Huang W. Accuracy of transvaginal sonoelastography for differential diagnosis between malignant and benign cervical lesions: A systematic review and meta-analysis. Cancer Med 2020; 9:7943-7953. [PMID: 32869506 PMCID: PMC7643678 DOI: 10.1002/cam4.3424] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2020] [Revised: 07/13/2020] [Accepted: 08/15/2020] [Indexed: 02/05/2023] Open
Abstract
BACKGROUND To evaluate the performance of transvaginal sonoelastography (TVSE) for differential diagnosis between malignant and benign cervical lesions using a meta-analysis. METHODS An independent literature search was conducted on the English medical database, including PubMed, Embase and Medline, Cochrane Library, Web of Science, and OVID. The diagnostic accuracy of TVSE was compared with that of histopathology, which is the gold reference standard for diagnosis. The accuracy of TVSE was assessed by calculating the pooled sensitivity, specificity, diagnostic odds ratio, and area under the curve (AUC). The imaging mechanisms, assessment methods, and QUADAS scores were assessed with a meta-regression analysis. A Deeks funnel plot was performed for evaluating publication bias. RESULTS Six eligible studies reported a total sample of 615 cervical lesions (415 cancers, 200 benign lesions). TVSE showed a pooled diagnostic odds ratio of 21.42 (95% CI 13.65-33.61), sensitivity of 0.87 (95% CI 0.84-0.90), specificity of 0.79 (95% CI 0.72-0.84), and an AUC of 0.892 (Q* = 0.822). The results of the meta-regression analysis showed that the imaging mechanism (P = .253), the assessment method (P = .279), or QUADAS score (P = .205) did not affect the study heterogeneity. CONCLUSION TVSE has a relatively high and satisfactory value for differential diagnosis between malignant and benign cervical lesions. The diagnostic performance of strain elastography and shear wave elastography were similar and good. However, to accommodate heterogeneity and publication bias, high-quality studies are required to further comparative effectiveness analyses to verify the efficacy of ultrasound detection.
Collapse
Affiliation(s)
- Yi Zhu
- Department of Ultrasound, the Affiliated Cancer Hospital, School of Medicine, University of Electronic Science and Technology of China, Sichuan Cancer Hospital and Institute, Chengdu, China.,Department of Ultrasound, West China Hospital, Sichuan University, Chengdu, China
| | - Xue-Feng Leng
- Department of Thoracic Surgery, the Affiliated Cancer Hospital, School of Medicine, University of Electronic Science and Technology of China, Sichuan Cancer Hospital and Institute, Chengdu, China
| | - Guo-Nan Zhang
- Department of Gynecological Oncology, the Affiliated Cancer Hospital, School of Medicine, University of Electronic Science and Technology of China, Sichuan Cancer Hospital and Institute, Chengdu, China
| | - Zi-Yi Huang
- Department of Bioinformatics, Basic Medical College of Chongqing Medical University, Chongqing, China
| | - Li Qiu
- Department of Ultrasound, West China Hospital, Sichuan University, Chengdu, China
| | - Wei Huang
- Department of Obstetrics and Gynecology, West China Second University Hospital, Sichuan University, Chengdu, China
| |
Collapse
|
11
|
Zhou B, Shao J, Kisby CK, Zhang X. Ultrasound vibro-elastography for assessing mechanical properties of porcine reproductive tissues in an ex vivo model. Clin Biomech (Bristol, Avon) 2020; 78:105093. [PMID: 32619871 DOI: 10.1016/j.clinbiomech.2020.105093] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/23/2019] [Revised: 06/09/2020] [Accepted: 06/12/2020] [Indexed: 02/07/2023]
Abstract
BACKGROUND The aim of this study was to use ultrasound vibro-elastography (UVE) for measuring surface wave speed and assessing mechanical properties of ex vivo porcine reproductive tissues, including the uterus, bladder, cornua and cervix. METHODS In UVE, a 0.1-s harmonic vibration at low frequency was generated on the tissue surface with a handheld shaker. A linear-array ultrasound probe was used to measure the resulting surface wave propagation. Surface wave speeds of tissues were measured in the frequency range of 100-300 Hz. Mechanical properties of the tissue were calculated based on wave speed dispersion with frequency. FINDINGS The obtained results showed that the surface wave speeds of porcine bladder, cervix, cornua and uterus increased with frequency. There were no statistically significant differences in the wave speeds or mechanical properties among the porcine bladder, cervix, cornua and uterus. INTERPRETATION Experimental data obtained in this study may be used as a reference to study in vivo surface wave speed or mechanical properties for porcine or human reproductive tissues.
Collapse
Affiliation(s)
- Boran Zhou
- Department of Radiology, Mayo Clinic, USA
| | - Juntao Shao
- Department of Radiology, Mayo Clinic, USA; Department of Ultrasound, The First Hospital of Qinhuangdao, Qinhuangdao, Hebei Province, China
| | - Cassandra K Kisby
- Division of Urogynecology, Department of Obstetrics & Gynecology, Mayo Clinic, USA
| | | |
Collapse
|
12
|
Castro L, García-Mejido JA, Arroyo E, Carrera J, Fernández-Palacín A, Sainz JA. Influence of epidemiological characteristics (age, parity and other factors) in the assessment of healthy uterine cervical stiffness evaluated through shear wave elastography as a prior step to its use in uterine cervical pathology. Arch Gynecol Obstet 2020; 302:753-762. [PMID: 32712928 DOI: 10.1007/s00404-020-05671-7] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2020] [Accepted: 06/25/2020] [Indexed: 12/17/2022]
Abstract
PURPOSE The purpose of this study was to evaluate stiffness changes occurring in the healthy uterine cervix according to age, parity, phase of the menstrual cycle and other factors by shear wave elastography (SWE). METHODS Evaluations of cervical speed and stiffness measurements were performed in 50 non-pregnant patients without gynaecological pathology using SWE transvaginal ultrasound. We performed the evaluation in the midsagittal plane of the uterine cervix with measurements at 0.5, 1 and 1.5 cm from external cervical os, at both anterior and posterior cervical lips. RESULTS We evaluated 44 patients by SWE and obtained a total average velocity of 3.48 ± 1.08 m/s and stiffness of 42.39 ± 25.33 kPa. We found differences in speed and stiffness according to the cervical lip and depth evaluated; thus, we observed a velocity of 2.70 m/s at 0.5 cm of depth in the anterior lip and 3.53 m/s at 1.5 cm of depth in the posterior lip (p < 0.05). We observed differences according to parity, obtaining a wave transmission speed of 2.67 m/s and 4.41 m/s at the cervical canal of nulliparous and multiparous patients, respectively (p < 0 0.002). We observed differences according to patient age (from a speed of 2.75 m/s at the cervical canal in the age group of 20-35 years to 5.05 m/s in the age group > 50 years) (p < 0.008). We did not observe differences in speed or stiffness according to the phase of the menstrual cycle, BMI, smoking status or the presence or absence of non-HPV infections. CONCLUSIONS The wave transmission speed and stiffness of the uterine cervix evaluated by SWE varies according to the cervical lip and depth of the evaluation as well as according to the parity and age of the patient.
Collapse
Affiliation(s)
- Laura Castro
- Department of Obstetrics and Gynecology, Valme University Hospital, Seville, Spain
| | - José Antonio García-Mejido
- Department of Obstetrics and Gynecology, Valme University Hospital, Seville, Spain.
- Biostatistics Unit, Department of Preventive Medicine and Public Health, University of Seville, Seville, Spain.
| | - Eva Arroyo
- Department of Obstetrics and Gynecology, Valme University Hospital, Seville, Spain
| | - Jara Carrera
- Department of Obstetrics and Gynecology, Valme University Hospital, Seville, Spain
| | - Ana Fernández-Palacín
- Biostatistics Unit, Department of Preventive Medicine and Public Health, University of Seville, Seville, Spain
| | - José Antonio Sainz
- Department of Obstetrics and Gynecology, Valme University Hospital, Seville, Spain
- Department of Obstetrics and Gynecology, University of Seville, Seville, Spain
| |
Collapse
|
13
|
Gargus ES, Jakubowski KL, Arenas GA, Miller SJ, Lee SSM, Woodruff TK. Ultrasound Shear Wave Velocity Varies Across Anatomical Region in Ex Vivo Bovine Ovaries. Tissue Eng Part A 2020; 26:720-732. [PMID: 32609070 DOI: 10.1089/ten.tea.2020.0037] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
The physical properties of the ovarian extracellular matrix (ECM) regulate the function of ovarian cells, specifically the ability of the ovary to maintain a quiescent primordial follicle pool while allowing a subset of follicles to grow and mature in the estrous cycle. Design of a long-term, cycling artificial ovary has been hindered by the limited information regarding the mechanical properties of the ovary. In particular, differences in the mechanical properties of the two ovarian compartments, the cortex and medulla, have never been quantified. Shear wave (SW) ultrasound elastography is an imaging modality that enables assessment of material properties, such as the mechanical properties, based on the velocity of SWs, and visualization of internal anatomy, when coupled with B-mode ultrasound. We used SW ultrasound elastography to assess whole, ex vivo bovine ovaries. We demonstrated, for the first time, a difference in mechanical properties, as inferred from SW velocity, between the cortex and medulla, as measured along the length (cortex: 2.57 ± 0.53 m/s, medulla: 2.87 ± 0.77 m/s, p < 0.0001) and width (cortex: 2.99 ± 0.81 m/s, medulla: 3.24 ± 0.97 m/s, p < 0.05) and that the spatial distribution and magnitude of SW velocity vary between these two anatomical planes. This work contributes to a larger body of literature assessing the mechanical properties of the ovary and related cells and specialized ECMs and will enable the rational design of biomimetic tissue engineered models and durable bioprostheses. Impact Statement Shear wave (SW) ultrasound elastography can be used to simultaneously assess the material properties and tissue structures when accompanied with B-mode ultrasound. We report a quantitative difference in mechanical properties, as inferred from SW velocity, between the cortex and medulla, with SW velocity being 11.4% and 8.4% higher in the medulla than the cortex when measured along the length and width, respectively. This investigation into the spatial and temporal variation in SW velocity in bovine ovaries will encourage and improve design of more biomimetic scaffolds for ovarian tissue engineering.
Collapse
Affiliation(s)
- Emma S Gargus
- Department of Obstetrics and Gynecology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA.,Simpson Querrey Institute for BioNanotechnology, Northwestern University, Chicago, Illinois, USA
| | - Kristen L Jakubowski
- Department of Physical Therapy and Movement Sciences, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA.,Department of Biomedical Engineering, Northwestern University, Evanston, Illinois, USA.,Shirley Ryan AbilityLab, Chicago, Illinois, USA
| | - Gabriel A Arenas
- Department of Obstetrics and Gynecology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
| | - Scott J Miller
- Department of Obstetrics and Gynecology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
| | - Sabrina S M Lee
- Department of Physical Therapy and Movement Sciences, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
| | - Teresa K Woodruff
- Department of Obstetrics and Gynecology, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
| |
Collapse
|
14
|
Fu B, Zhang H, Song ZW, Lu JX, Wu SH, Li J. Value of shear wave elastography in the diagnosis and evaluation of cervical cancer. Oncol Lett 2020; 20:2232-2238. [PMID: 32782540 PMCID: PMC7400132 DOI: 10.3892/ol.2020.11759] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2019] [Accepted: 02/28/2020] [Indexed: 12/26/2022] Open
Abstract
The aim of the present study was to explore the value of shear wave elastography (SWE) in the differential diagnosis of cervical disease and to evaluate the infiltration of cervical cancer. A total of 40 inpatients with cervical cancer, 40 inpatients with cervical benign lesion and 40 healthy volunteers encountered between October 2014 and January 2017 were enrolled. All patients and volunteers underwent conventional ultrasound (US) and SWE examinations. The malignancy and the size (including long, tranverse and anteroposterior diameter) of the lesion were assessed on US. The elastic score, strain ratio, shear wave speed (SWS) and the size of lesions were determined on SWE. Infiltration of the uterus and vaginal vault were also evaluated on US and SWE. The SWS values of cervical cancers, cervical benign lesions and normal cervixes groups were compared. The results suggested that the optimal cut-off elasticity score for predicting cervical cancers was 3 points. The strain ratio between the cervical cancers and the cervical benign lesions exhibited a significant difference (P<0.01). The mean value of SWS for cervical cancers was significantly higher than that of cervical benign lesions and normal cervix (P<0.05). Regarding the lesion size and volume, SWE and pathological measurements were larger than those determined by US (P<0.05 for each). The lesion volume on SWE and pathological measurements exhibited no significant difference (P>0.05). Compared to the pathological diagnosis of focal infiltration of uterus and vaginal vault, the diagnostic accuracy of SWE was higher than that of US. In conclusion, SWE may be used to differentiate between cervical benign lesions and cervical cancers. The elastic score, strain ratio and SWS of cervical cancers were higher than those of cervical benign lesions. Furthermore, SWE is able to evaluate the infiltration of cervical cancer.
Collapse
Affiliation(s)
- Bing Fu
- Department of Ultrasound, Qilu Hospital of Shandong University, Jinan, Shandong 250012, P.R. China.,Department of Ultrasound, Linyi People's Hospital, Linyi, Shandong 276003, P.R. China
| | - Hong Zhang
- Department of Archives, Linyi People's Hospital, Linyi, Shandong 276003, P.R. China
| | - Zhen-Wei Song
- Department of Medical Imaging, Linyi People's Hospital, Linyi, Shandong 276003, P.R. China
| | - Ji-Xiang Lu
- Department of Medical Imaging, Linyi People's Hospital, Linyi, Shandong 276003, P.R. China
| | - Shi-Hui Wu
- Department of Ultrasound, Linyi People's Hospital, Linyi, Shandong 276003, P.R. China
| | - Jie Li
- Department of Ultrasound, Qilu Hospital of Shandong University, Jinan, Shandong 250012, P.R. China
| |
Collapse
|
15
|
Gao L, Lin Y, Jiang Y, Li H, Gao Q, Xi X, Wang Y, Yang X, Lai X, Zhu S, Zhang X, Zhao R, Zhang B. Ultrasound characteristics of cervical lesions in patients with radioiodine refractory differentiated thyroid cancer: A strobe-compliant article. Medicine (Baltimore) 2019; 98:e17876. [PMID: 31702656 PMCID: PMC6855643 DOI: 10.1097/md.0000000000017876] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/29/2022] Open
Abstract
Radioiodine refractory (RAIR) is the major cause of thyroid cancer-related death. In order to avoid needless Radioiodine (RAI) therapy, recognizing the RAIR cases in time is important for the patients to obtain more time for the effective therapy.Evaluate the ultrasound features of cervical metastatic lymph node in patients with RAIR differentiated thyroid cancer (DTC).Seventeen adult patients with histologically confirmed locally advanced or metastatic RAIR-DTC were prospectively enrolled. The ultrasound (US) characteristics of cervical lesions in patients with the RAIR-DTC were compared with cervical lymph node metastasis from 59 non RAIR-DTC cases.Among the 17 patients, cervical lymph node metastasis was found in 15 patients (88.3%). The cervical lesions of RAIR-DTC (mean size, 2.0 cm) were larger than that in non RAIR-DTC group (mean size, 1.30 cm). More multiple lesions and more lesions with visible flow were found in the RAIR Group, while fewer hyperechogenic punctuations were found in RAIR group (P < .05). The distant metastasis rates showed that RAIR-DTC led to a poorer prognosis than those of patients in the non RAIR Group (P < .01).Ultrasound can help distinguish metastasized cervical lymph nodes of RAIR-DTC patients from non RAIR-DTC patients. For RAIR-DTC patients, a long-term US evaluation should be performed.
Collapse
Affiliation(s)
| | - Yansong Lin
- Department of Nuclear Medicine, Chinese Academy of Medical Sciences & Peking Union Medical College Hospital
| | | | - Hui Li
- Department of Nuclear Medicine, Chinese Academy of Medical Sciences & Peking Union Medical College Hospital
| | | | | | | | | | | | | | | | | | - Bo Zhang
- Department of Ultrasound
- Department of Ultrasound, China-Japan Friendship Hospital, Beijing, China
| |
Collapse
|
16
|
Strain elastography as an early predictor of long-term prognosis in patients with locally advanced cervical cancers treated with concurrent chemoradiotherapy. Eur Radiol 2019; 30:471-481. [PMID: 31359126 DOI: 10.1007/s00330-019-06345-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2019] [Revised: 06/06/2019] [Accepted: 06/27/2019] [Indexed: 01/02/2023]
Abstract
OBJECTIVE To explore the value of strain elastography as an early predictor of long-term prognosis in patients with locally advanced cervical cancers treated with concurrent chemoradiotherapy (CCRT). METHODS Strain elastography examinations were performed on 45 patients with locally advanced cervical cancers at 3 time points: prior to CCRT, and at 1 and 2 weeks after the start of CCRT. The maximum tumor diameter (Dmax), strain ratio (SR), and their percentage changes (ΔDmax and ΔSR) were calculated to predict long-term prognosis. Based on the results of physical examinations, Papanicolaou test, and pelvic magnetic resonance imaging, we classified patients into two groups: responders (complete remission) and non-responders (sustained disease, recurrence, or death). RESULTS After a median follow-up of 30 months (range, 12-36 months), 36 of 45 (80%) patients were disease free. The Dmax as well as ΔDmax at 2 weeks during CCRT was able to predict the responder outcomes, with an area-under-the-curve (AUC) of 0.733 and 0.731, respectively. Furthermore, significant differences in SR and ΔSR at 1 and 2 weeks during therapy were shown between the responder and non-responder groups (all p < 0.05), and ΔSR at 2 weeks during CCRT presented with the highest AUC (0.91), yielding 88.9% sensitivity and 88.9% specificity with a selected cutoff value. CONCLUSIONS Strain elastography may be useful as an early predictor of long-term outcomes after CCRT for patients with cervical cancer. KEY POINTS • The D maxas well as ΔD maxat 2 weeks during CCRT can predict the responder outcomes. • The elastography parameters (SR and ΔSR) exhibited predictive values of favorable response after therapy initiation. • ΔSR at 2 weeks during CCRT held the best predictive value for the responder outcomes.
Collapse
|
17
|
Horvath L, Kraft M. Evaluation of ultrasound and fine-needle aspiration in the assessment of head and neck lesions. Eur Arch Otorhinolaryngol 2019; 276:2903-2911. [DOI: 10.1007/s00405-019-05552-z] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2019] [Accepted: 07/06/2019] [Indexed: 12/17/2022]
|
18
|
Wang B, Zhang Y, Chen S, Xiang X, Wen J, Yi M, He B, Hu B. Diagnostic accuracy of cervical elastography in predicting preterm delivery: A systematic review and meta-analysis. Medicine (Baltimore) 2019; 98:e16449. [PMID: 31335700 PMCID: PMC6708731 DOI: 10.1097/md.0000000000016449] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
BACKGROUND The aim of the study was to evaluate the diagnostic accuracy of cervical elastography in predicting preterm delivery (PTD). METHODS We searched the PubMed, EMBASE, and Cochrane databases to identify relevant studies that applied ultrasound (US) elastography to assess cervical stiffness and predict PTD. All the studies were published before December 11, 2018, and only studies published in English were collected. The cervical length (CL) was considered a comparator, and the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool was applied to assess the quality of the included studies. Summary receiver operating characteristic (SROC) modeling was performed to evaluate the diagnostic performance of cervical elastography in predicting PTD. Subgroup analyses were also performed. RESULTS Seven studies, including 1488 pregnant women, were included in this meta-analysis. Cervical elastography showed a summary sensitivity of 0.84 [95% confidence interval (CI): 0.68, 0.93], a specificity of 0.82 (95% CI: 0.63, 0.93), a diagnostic odds ratio of 25 (95% CI: 7, 93), and an area under the curve (AUC) of SROC of 0.90 (95% CI: 0.87-0.93). CL measurement showed that the AUC of SROC was 0.60 (95% CI: 0.56-0.64). The results of subgroup analysis showed that the summary sensitivity and specificity were different in the QUADAS-2 score subgroups. CONCLUSION Cervical elastography is a promising and reliable method to predict PTD. Cervical elastography showed better diagnostic performance to predict PTD than CL measurement.
Collapse
Affiliation(s)
- Bo Wang
- Department of Ultrasonic Imaging, Affiliated Renhe Hospital of China Three Gorges University, Yichang
| | - Yong Zhang
- Department of Nephrology, The First Affiliated Hospital of Yangtze University, Jingzhou
| | - Shuangshuang Chen
- Department of Ultrasonic Imaging, Affiliated Renhe Hospital of China Three Gorges University, Yichang
| | - Xiaowei Xiang
- Department of Ultrasonic Imaging, Affiliated Renhe Hospital of China Three Gorges University, Yichang
| | - Juan Wen
- Department of Ultrasonic Imaging, Affiliated Renhe Hospital of China Three Gorges University, Yichang
| | - Mei Yi
- Department of Ultrasonic Imaging, Affiliated Renhe Hospital of China Three Gorges University, Yichang
| | - Baiyun He
- Department of Gynecology and Obstetrics, Affiliated Renhe Hospital of China Three Gorges University, Yichang, Hubei, PR China
| | - Bing Hu
- Department of Ultrasonic Imaging, Affiliated Renhe Hospital of China Three Gorges University, Yichang
| |
Collapse
|
19
|
Marcomini KD, Fleury EFC, Oliveira VM, Carneiro AAO, Schiabel H, Nishikawa RM. Evaluation of a Computer-Aided Diagnosis System in the Classification of Lesions in Breast Strain Elastography Imaging. Bioengineering (Basel) 2018; 5:bioengineering5030062. [PMID: 30096868 PMCID: PMC6165254 DOI: 10.3390/bioengineering5030062] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2018] [Revised: 07/27/2018] [Accepted: 08/06/2018] [Indexed: 11/16/2022] Open
Abstract
Purpose: Evaluation of the performance of a computer-aided diagnosis (CAD) system based on the quantified color distribution in strain elastography imaging to evaluate the malignancy of breast tumors. Methods: The database consisted of 31 malignant and 52 benign lesions. A radiologist who was blinded to the diagnosis performed the visual analysis of the lesions. After six months with no eye contact on the breast images, the same radiologist and other two radiologists manually drew the contour of the lesions in B-mode ultrasound, which was masked in the elastography image. In order to measure the amount of hard tissue in a lesion, we developed a CAD system able to identify the amount of hard tissue, represented by red color, and quantify its predominance in a lesion, allowing classification as soft, intermediate, or hard. The data obtained with the CAD system were compared with the visual analysis. We calculated the sensitivity, specificity, and area under the curve (AUC) for the classification using the CAD system from the manual delineation of the contour by each radiologist. Results: The performance of the CAD system for the most experienced radiologist achieved sensitivity of 70.97%, specificity of 88.46%, and AUC of 0.853. The system presented better performance compared with his visual diagnosis, whose sensitivity, specificity, and AUC were 61.29%, 88.46%, and 0.829, respectively. The system obtained sensitivity, specificity, and AUC of 67.70%, 84.60%, and 0.783, respectively, for images segmented by Radiologist 2, and 51.60%, 92.30%, and 0.771, respectively, for those segmented by the Resident. The intra-class correlation coefficient was 0.748. The inter-observer agreement of the CAD system with the different contours was good in all comparisons. Conclusions: The proposed CAD system can improve the radiologist performance for classifying breast masses, with excellent inter-observer agreement. It could be a promising tool for clinical use.
Collapse
Affiliation(s)
- Karem D Marcomini
- Department of Electrical and Computer Engineering, University of São Paulo, 400 Trabalhador São-carlense Av., São Carlos 13566-590, Brazil.
| | - Eduardo F C Fleury
- Brazilian Institute for Cancer Control, 2576 Alcântara Machado Av., São Paulo 03101-005, Brazil.
| | - Vilmar M Oliveira
- Faculty of Medical Sciences of Santa Casa de São Paulo, 61 Doutor Cesário Motta Júnior St., São Paulo 01221-020, Brazil.
| | - Antonio A O Carneiro
- Department of Physics, University of São Paulo, 3900 Bandeirantes Av., Ribeirão Preto 14040-901, Brazil.
| | - Homero Schiabel
- Department of Electrical and Computer Engineering, University of São Paulo, 400 Trabalhador São-carlense Av., São Carlos 13566-590, Brazil.
| | - Robert M Nishikawa
- Department of Radiology, University of Pittsburgh, 3362 Fifth Av., Pittsburgh, PA 15123, USA.
| |
Collapse
|
20
|
Stoelinga B, Hehenkamp WJK, Nieuwenhuis LL, Conijn MMA, van Waesberghe JHTM, Brölmann HAM, Huirne JAF. Accuracy and Reproducibility of Sonoelastography for the Assessment of Fibroids and Adenomyosis, with Magnetic Resonance Imaging as Reference Standard. ULTRASOUND IN MEDICINE & BIOLOGY 2018; 44:1654-1663. [PMID: 29784438 DOI: 10.1016/j.ultrasmedbio.2018.03.027] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/18/2017] [Revised: 02/02/2018] [Accepted: 03/29/2018] [Indexed: 06/08/2023]
Abstract
The aims of this prospective diagnostic evaluation study were (i) to estimate the inter-observer agreement and reproducibility of real-time sonoelastography and real-time gray-scale ultrasound in the measurement of uterine and fibroid volumes; (ii) to evaluate the agreement between real-time gray-scale ultrasound, sonoelastography and magnetic resonance imaging with respect to these outcomes; and (iii) to evaluate the diagnostic accuracy of sonoelastography in the diagnosis of uterine pathology on stored sonoelastography and gray-scale cine loops. Women without a history of uterine pathology and with the diagnosis intrauterine fibroids or adenomyosis were included. All participants underwent gray-scale ultrasound, sonoelastography and magnetic resonance imaging. Compression sonoelastography was found to have high inter-observer and inter-method agreement for the measurement of uterine and fibroid volumes. The addition of sonoelastography to gray-scale ultrasound seems to be useful in the differentiation between fibroids, adenomyosis and normal uteri as reflected by an increase in accuracy and diagnostic agreement.
Collapse
Affiliation(s)
- Barbara Stoelinga
- Department of Obstetrics and Gynecology, Vrije Universiteit Medical Center, Amsterdam, The Netherlands.
| | - Wouter J K Hehenkamp
- Department of Obstetrics and Gynecology, Vrije Universiteit Medical Center, Amsterdam, The Netherlands
| | - Lotte L Nieuwenhuis
- Department of Obstetrics and Gynecology, Vrije Universiteit Medical Center, Amsterdam, The Netherlands
| | - Mandy M A Conijn
- Department of Radiology, Vrije Universiteit Medical Center, Amsterdam, The Netherlands
| | | | - Hans A M Brölmann
- Department of Obstetrics and Gynecology, Vrije Universiteit Medical Center, Amsterdam, The Netherlands
| | - Judith A F Huirne
- Department of Obstetrics and Gynecology, Vrije Universiteit Medical Center, Amsterdam, The Netherlands
| |
Collapse
|
21
|
Abstract
Pelvic ultrasound examination is the primary imaging modality for evaluating a wide range of female pelvic symptomatology, and is often the first imaging test to detect a gynecologic malignancy. Ultrasound imaging is particularly useful for evaluating the thickness and appearance of the endometrium in patients with abnormal bleeding, and in detecting and characterizing ovarian lesions. This article reviews the ultrasound appearance of gynecologic neoplasms grouped by anatomic site of origin, the ultrasound appearance of select benign pelvic pathology not to be misinterpreted as malignancy, as well as available ultrasound imaging-based guidelines for managing potential gynecologic neoplasms.
Collapse
|
22
|
Xu Y, Zhu L, Liu B, Ru T, Wang H, He J, Liu S, Yang X, Zhou Z, Liu T. Strain elastography imaging for early detection and prediction of tumor response to concurrent chemo-radiotherapy in locally advanced cervical cancer: feasibility study. BMC Cancer 2017. [PMID: 28629386 PMCID: PMC5477276 DOI: 10.1186/s12885-017-3411-5] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023] Open
Abstract
Background To investigate the feasibility of strain elastography imaging in early detecting and predicting treatment response in patients receiving concurrent chemo-radiotherapy (CCRT) for locally advanced cervical cancer. Methods Between January 2015 and June 2016, 47 patients with locally advanced cervical cancer were enrolled in a feasibility study approved by the institutional review board. All patients underwent CCRT and received strain elastography examinations at 4 time points: pre-therapy (baseline), 1 week and 2 weeks during, as well as immediately post CCRT. Treatment response was evaluated by MRI at the time of diagnosis and immediately after CCRT. Based on the MRI findings, the treatment outcome was characterized as complete response (CR), partial response (PR), stable disease (SD) and progressive disease (PD). Strain ratio of the normal parametrial tissue vs. cervical tumor was calculated and compared with the clinical outcome. Results Out of the 47 patients, 36 patients who completed all 4 examinations were included in the analyses: 25 were classified as CR, 11 as PR, and 0 in the SD/PD groups. Strain ratios were significantly different among the time points in both the CR group (F = 87.004, p < 0.001) and PR group (F = 38.317, p < 0.001). Strain ratios were significantly difference between the CR and PR groups (F = 7.203 p = 0.011). Strain ratios between the CR group and PR group were significantly different at 1 week after treatment initiation (p < 0.05). Compared to the baseline, a significant decrease in the CR group was observed at week 1, week 2 and post treatment (all p < 0.001), while a significant decrease in the PR group was shown in week 2 and post treatment (both p < 0.05), but not at week 1 during CCRT (p = 0.084). Conclusions We have conducted a prospective longitudinal study to evaluate tumor response in women receiving CCRT for cervical cancers. This study has demonstrated the potential of strain elastography imaging in monitoring and early predicting tumor response induced by CCRT. Electronic supplementary material The online version of this article (doi:10.1186/s12885-017-3411-5) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Yan Xu
- Department of Radiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, 210008, China.,Department of Obstetrics and Gynecology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, 210008, China
| | - Lijing Zhu
- The Comprehensive Cancer Centre of Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, 210008, China
| | - Baorui Liu
- The Comprehensive Cancer Centre of Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, 210008, China
| | - Tong Ru
- Department of Obstetrics and Gynecology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, 210008, China
| | - Huanhuan Wang
- Department of Radiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, 210008, China
| | - Jian He
- Department of Radiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, 210008, China
| | - Song Liu
- Department of Radiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, 210008, China
| | - Xiaofeng Yang
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA, 30322, USA
| | - Zhengyang Zhou
- Department of Radiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, 210008, China.
| | - Tian Liu
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA, 30322, USA.
| |
Collapse
|
23
|
Ma X, Li Q, Wang JL, Shao J, Zhu YC, Ding W, Zhang HS, Wang HY, Shen JK. Comparison of elastography based on transvaginal ultrasound and MRI in assessing parametrial invasion of cervical cancer. Clin Hemorheol Microcirc 2017; 66:27-35. [PMID: 28211804 DOI: 10.3233/ch-16235] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Affiliation(s)
- Xi Ma
- Department of Ultrasound Diagnosis, Kunshan Hospital Affiliated to Jiangsu University, Kunshan, Jiangsu, China
| | - Qi Li
- Department of Ultrasound Diagnosis, Kunshan Hospital Affiliated to Jiangsu University, Kunshan, Jiangsu, China
| | - Jian-liang Wang
- Department of Radiology Diagnosis, Kunshan Hospital Affiliated to Jiangsu University, Kunshan, Jiangsu, China
| | - Jun Shao
- Department of Ultrasound Diagnosis, Kunshan Hospital Affiliated to Jiangsu University, Kunshan, Jiangsu, China
| | - Yu-chun Zhu
- Department of Radiology Diagnosis, Kunshan Hospital Affiliated to Jiangsu University, Kunshan, Jiangsu, China
| | - Wei Ding
- Department of Ultrasound Diagnosis, Kunshan Hospital Affiliated to Jiangsu University, Kunshan, Jiangsu, China
| | - Hou-sheng Zhang
- Department of Ultrasound Diagnosis, Kunshan Hospital Affiliated to Jiangsu University, Kunshan, Jiangsu, China
| | - Hong-yan Wang
- Department of Radiology Diagnosis, Kunshan Hospital Affiliated to Jiangsu University, Kunshan, Jiangsu, China
| | - Jun-kang Shen
- Department of Radiology, The Second Affiliated Hospital of Soochow University, Institute of Radiotherapy & Oncology, Soochow University, Suzhou, China
| |
Collapse
|
24
|
Czuczwar P, Wozniak S, Szkodziak P, Kudla MJ, Pyra K, Paszkowski T. Elastography Improves the Diagnostic Accuracy of Sonography in Differentiating Endometrial Polyps and Submucosal Fibroids. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2016; 35:2389-2395. [PMID: 27629761 DOI: 10.7863/ultra.15.12017] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/08/2015] [Accepted: 02/18/2016] [Indexed: 06/06/2023]
Abstract
OBJECTIVES To assess whether strain elastography may be used to visualize the different stiffness of endometrial polyps and submucosal fibroids. METHODS We conducted a prospective monocentric single-operator study on diagnostic accuracy. Patients who qualified for hysteroscopy because of suspected endometrial polyps and submucosal fibroids were included. Before the procedure, all patients underwent routine sonographic and power Doppler examinations. Additionally, the stiffness of intrauterine lesions was assessed by strain elastography. The enhancement was adjusted to visualize hard myometrium and soft endometrium around the intrauterine lesion. Due to their histologic structure, we assumed that on strain elastography, endometrial polyps should appear as soft lesions, whereas submucosal fibroids should appear as hard lesions. Sonographic, power Doppler, and elastographic findings were verified by pathologic examinations after hysteroscopies. The diagnostic accuracy of sonography, power Doppler imaging, and strain elastography was compared by the McNemar test. RESULTS Forty-seven patients were included and underwent hysteroscopy. In 29 cases, endometrial polyps were found, and in 18, submucosal fibroids were found. The diagnostic accuracy rates for B-mode sonography, power Doppler imaging, and strain elastography in distinguishing endometrial polyps and submucosal fibroids were 70.2%, 65.9%, and 89.4%, respectively. The proportion of correct findings was significantly higher for strain elastography than for B-mode sonography (P = .0265) and power Doppler imaging (P = .0153). CONCLUSIONS Strain elastography complements sonography in differentiating intrauterine lesions. Strain elastography may be used to visualize the different stiffness of endometrial polyps and submucosal fibroids.
Collapse
Affiliation(s)
- Piotr Czuczwar
- Third Department of Gynecology, Medical University of Lublin, Lublin, Poland
| | - Slawomir Wozniak
- Third Department of Gynecology, Medical University of Lublin, Lublin, Poland
| | - Piotr Szkodziak
- Third Department of Gynecology, Medical University of Lublin, Lublin, Poland
| | - Marek J Kudla
- Department of Obstetrics and Gynecology, Medical University of Silesia, Katowice, Poland
| | - Krzysztof Pyra
- Department of Interventional Radiology and Neuroradiology, Medical University of Lublin, Lublin, Poland
| | - Tomasz Paszkowski
- Third Department of Gynecology, Medical University of Lublin, Lublin, Poland
| |
Collapse
|
25
|
Horrow MM. Invited Commentary on “US of the Nongravid Cervix with Multimodality Imaging Correlation”. Radiographics 2016; 36:617-9. [DOI: 10.1148/rg.2016160001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
26
|
Mu WJ, Zhong WJ, Yao JY, Li LJ, Peng YL, Wang Y, Liu LS, Xiao Y, Liu SJ, Wu CJ, Jiang YX, Parajuly SS, Xu P, Hao Y, Li J, Luo BM, Zhi H. Ultrasonic Elastography Research Based on a Multicenter Study: Adding Strain Ratio after 5-Point Scoring Evaluation or Not. PLoS One 2016; 11:e0148330. [PMID: 26863208 PMCID: PMC4749284 DOI: 10.1371/journal.pone.0148330] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2015] [Accepted: 01/15/2016] [Indexed: 02/05/2023] Open
Abstract
Background This study aimed to confirm whether strain ratio should be added after evaluation of lesions with 5-point elasticity scoring for differentiating benign and malignant breast lesions on ultrasonographic elastography(UE). Materials and Methods From June 2010 to March 2012, 1080 consecutive female patients with breast lesions were recruited into a multicenter retrospective study, which involved 8 centers across China. Each institutional ethic review board approved the study, and all the patients gave written informed consent. All the patients underwent the UE procedure and the strain ratios were calculated and the final diagnosis was made by histological findings. The sensitivity, specificity, accuracy, PPV and NPV were calculated for each of the two evaluation systems and the areas under the ROC curve were compared. Results The strain ratios of benign lesions (mean, 2.6±2.0) and malignant lesions (mean,7.9±5.8) were significantly different (p <0.01). When the cutoff point was 3.01, strain ratio method had 79.8% sensitivity, 82.8% specificity, and 81.3% accuracy, while the 5-point scoring method had 93.1% sensitivity, 73.0% specificity, and 76.8% accuracy. The areas under the ROC curve with the strain ratio method and 5-point scoring method were 0.863 and 0.865, respectively(p>0.05). The strain ratio method shows better a diagnosis performance of the lesions with elasticity score 3 and 4. Conclusions Although the two UE methods have similar diagnostic performance, separate calculation of the strain ratios seems compulsory, especially for the large solid breast lesions and the lesions with elasticity score 3 and 4.
Collapse
Affiliation(s)
- Wen-Jie Mu
- Department of Ultrasound, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, Guangdong Province, China
| | - Wen-Jing Zhong
- Department of Ultrasound, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, Guangdong Province, China
| | - Ji-Yi Yao
- Department of Ultrasound, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, Guangdong Province, China
| | - Lu-Jing Li
- Department of Ultrasound, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, Guangdong Province, China
| | - Yu-lan Peng
- Department of Diagnostic Ultrasound and The National Key Discipline of Medical Imaging and Nuclear Medicine, West China Hospital of Sichuan University, Chengdu, Sichuan Province, China
| | - Yi Wang
- Department of Ultrasound, Huashan Hospital, Fudan University, Shanghai, Zhejiang Province, China
| | - Li-sha Liu
- Department of Ultrasound, Tumor Hospital Affiliated to Xinjiang Medical University, Urumqi, Xinjiang Province, China
| | - Ying Xiao
- Department of Ultrasound, Xiangya Hospital, Central-South University, Changsha, Hunan Province, China
| | - Shou-jun Liu
- Department of Ultrasound, ShengJing hospital of China Medical University, Shenyang, Liaoning Province, China
| | - Chang-jun Wu
- Department of Ultrasound, The First Affiliated Hospital of Harbin Medical University, Harbin, Heilongjiang Province, China
| | - Yu-xin Jiang
- Department of Ultrasound, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, Hebei Province, China
| | - Shyam Sundar Parajuly
- Department of Diagnostic Ultrasound and The National Key Discipline of Medical Imaging and Nuclear Medicine, West China Hospital of Sichuan University, Chengdu, Sichuan Province, China
| | - Ping Xu
- Department of Ultrasound, Huashan Hospital, Fudan University, Shanghai, Zhejiang Province, China
| | - Yi Hao
- Department of Ultrasound, Tumor Hospital Affiliated to Xinjiang Medical University, Urumqi, Xinjiang Province, China
| | - Jing Li
- Department of Ultrasound, ShengJing hospital of China Medical University, Shenyang, Liaoning Province, China
| | - Bao-Ming Luo
- Department of Ultrasound, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, Guangdong Province, China
- * E-mail: (BML); (HZ)
| | - Hui Zhi
- Department of Ultrasound, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, Guangdong Province, China
- * E-mail: (BML); (HZ)
| |
Collapse
|