1
|
Application of Color Doppler with 3- and 4-Dimensional Ultrasonography in the Prenatal Evaluation of Fetal Extracardiac and Placental Abnormalities. Healthcare (Basel) 2023; 11:healthcare11040488. [PMID: 36833022 PMCID: PMC9956359 DOI: 10.3390/healthcare11040488] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2022] [Revised: 02/05/2023] [Accepted: 02/07/2023] [Indexed: 02/11/2023] Open
Abstract
Using color Doppler flow imaging or high-definition flow imaging with three-dimensional volume or spatio-temporal image correlation (STIC) in the glass-body mode allows displaying both gray-scale and color information of the heart cycle-related flow events and vessel spatial relationship. Conventionally, STIC in the glass-body mode has been used to examine the fetal heart and assess heart defects. Recently, a novel application of STIC in the visualization of abdominal precordial veins and intraplacental vascularization in singleton pregnancies has been reported. The aim of this present review is to discuss the use of color Doppler with three- and four-dimensional ultrasonography in the evaluation of extracardiac, placental, umbilical cord and twin abnormalities with examples. The glass-body mode is complementary to conventional 2D ultrasonography. Further studies are required to investigate use of the glass-body mode in the assessment of intraplacental vascularization in singleton and twin pregnancies.
Collapse
|
2
|
A 10-Year Retrospective Review of Prenatal Applications, Current Challenges and Future Prospects of Three-Dimensional Sonoangiography. Diagnostics (Basel) 2021; 11:diagnostics11081511. [PMID: 34441444 PMCID: PMC8394388 DOI: 10.3390/diagnostics11081511] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2021] [Revised: 08/14/2021] [Accepted: 08/18/2021] [Indexed: 12/12/2022] Open
Abstract
Realistic reconstruction of angioarchitecture within the morphological landmark with three-dimensional sonoangiography (three-dimensional power Doppler; 3D PD) may augment standard prenatal ultrasound and Doppler assessments. This study aimed to (a) present a technical overview, (b) determine additional advantages, (c) identify current challenges, and (d) predict trajectories of 3D PD for prenatal assessments. PubMed and Scopus databases for the last decade were searched. Although 307 publications addressed our objectives, their heterogeneity was too broad for statistical analyses. Important findings are therefore presented in descriptive format and supplemented with the authors’ 3D PD images. Acquisition, analysis, and display techniques need to be personalized to improve the quality of flow-volume data. While 3D PD indices of the first-trimester placenta may improve the prediction of preeclampsia, research is needed to standardize the measurement protocol. In highly experienced hands, the unique 3D PD findings improve the diagnostic accuracy of placenta accreta spectrum. A lack of quality assurance is the central challenge to incorporating 3D PD in prenatal care. Machine learning may broaden clinical translations of prenatal 3D PD. Due to its operator dependency, 3D PD has low reproducibility. Until standardization and quality assurance protocols are established, its use as a stand-alone clinical or research tool cannot be recommended.
Collapse
|
3
|
Marinelli JVC, Filho AGDA, de Barros MF, Rodrigues AS, Francisco RPV, Carvalho MHBD. Women's Obstetric History and Midtrimester Cervical Length Measurements by 2D/3D and Doppler Ultrasound. REVISTA BRASILEIRA DE GINECOLOGIA E OBSTETRÍCIA 2020; 42:540-546. [PMID: 32575132 PMCID: PMC10309237 DOI: 10.1055/s-0040-1713010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022] Open
Abstract
OBJECTIVE The aim of the present study was to compare the obstetric history and both two- and tri-dimensional ultrasound parameters according to different cervical lengths. METHODS The present cross-sectional study analyzed 248 midtrimester pregnant women according to cervical length and compared the data with the obstetric history and 2D/3D ultrasound parameters. Patients were divided into 3 groups according to cervical length: The Short Cervix group for cervical lengths ≥ 15 mm and < 25 mm (n = 68), the Very Short Cervix group for cervical lengths < 15 mm (n = 18) and the Control group, composed of 162 pregnant women with uterine cervical lengths ≥ 25 mm. RESULTS When analyzing the obstetric history of only non-nulliparous patients, a significant association between the presence of a short cervix in the current pregnancy and at least one previous preterm birth was reported (p = 0.021). Cervical length and volume were positively correlated (Pearson coefficient = 0.587, p < 0.0001). The flow index (FI) parameter of cervical vascularization was significantly different between the Control and Very Short Cervix groups. However, after linear regression, in the presence of volume information, we found no association between the groups and FI. Uterine artery Doppler was also not related to cervical shortening. CONCLUSION The present study showed a significant association between the presence of a short cervix in the current pregnancy and at least one previous preterm birth. None of the vascularization indexes correlate with cervical length as an independent parameter. Uterine artery Doppler findings do not correlate with cervical length.
Collapse
Affiliation(s)
| | - Antonio Gomes de Amorim Filho
- Obstetric Clinic Division, Hospital das Clinicas (HCFMUSP), Faculdade de Medicina, Universidade de São Paulo, São Paulo, Brazil
| | - Monica Fairbanks de Barros
- Obstetric Clinic Division, Hospital das Clinicas (HCFMUSP), Faculdade de Medicina, Universidade de São Paulo, São Paulo, Brazil
| | - Agatha Sacramento Rodrigues
- Obstetrics Discipline, Department of Obstetrics and Gynecology, Faculdade de Medicina, Universidade de São Paulo, São Paulo, Brazil
| | | | | |
Collapse
|
4
|
Wataganara T, Yapan P, Moungmaithong S, Sompagdee N, Phithakwatchara N, Limsiri P, Nawapun K, Rekhawasin T, Talungchit P. Additional benefits of three-dimensional ultrasound for prenatal assessment of twins. J Perinat Med 2020; 48:102-114. [PMID: 31961794 DOI: 10.1515/jpm-2019-0409] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/05/2019] [Accepted: 12/05/2019] [Indexed: 12/18/2022]
Abstract
Three-dimensional ultrasound (3DUS) may provide additional information for prenatal assessment of twins. It may improve the diagnostic confidence of dating, nuchal translucency (NT) and chorionicity assignment in twin pregnancies. The "virtual 3DUS placentoscopy" can guide selective fetoscopic laser photocoagulation (SFLP) to treat twin-twin transfusion syndrome (TTTS). Volumetric assessment of the dysmorphic acardiac twin with the Virtual Organ Computer-aided Analysis (VOCAL) software is more accurate than the conventional ultrasound measurement. Twin anemia polycythemia (TAP) sequence and selective intrauterine growth restriction (sIUGR) may be clinically monitored with 3DUS placental volume (PV) and power Doppler vascular indices. Congenital anomalies are more common in twins. Evaluation of fetal anomalies with 3DUS could assist perinatal management. The 3DUS power Doppler can provide a better understanding of true and false umbilical cord knots, which are commonly found in monoamniotic (MA) twins. Single demise in monochorionic (MC) twin pregnancies can cause severe neurologic morbidity in the surviving co-twin. Prenatal prediction of brain injury in the surviving co-twin with unremarkable neurosonographic examination is difficult. The 3DUS power Doppler may aid in prenatal detection of subtle abnormal cerebral perfusion. Prenatal assessment of conjoined twins with 3DUS is important if emergency postnatal surgical separation is anticipated. There is no significant additional advantage in using real-time 3DUS to guide prenatal interventions. Assessment of the cervix and pelvic floor during twin pregnancies is enhanced with 3DUS. Due to lack of high-quality studies, routine prenatal 3DUS in twin pregnancies needs to be balanced with risks of excessive ultrasound exposure.
Collapse
Affiliation(s)
- Tuangsit Wataganara
- Department of Obstetrics and Gynecology, Division of Maternal-Fetal Medicine, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok 10700, Thailand
| | - Piengbulan Yapan
- Department of Obstetrics and Gynecology, Division of Maternal-Fetal Medicine, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok 10700, Thailand
| | - Sakita Moungmaithong
- Department of Obstetrics and Gynecology, Division of Maternal-Fetal Medicine, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok 10700, Thailand
| | - Nalat Sompagdee
- Department of Obstetrics and Gynecology, Division of Maternal-Fetal Medicine, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok 10700, Thailand
| | - Nisarat Phithakwatchara
- Department of Obstetrics and Gynecology, Division of Maternal-Fetal Medicine, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok 10700, Thailand
| | - Pattarawan Limsiri
- Department of Obstetrics and Gynecology, Division of Maternal-Fetal Medicine, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok 10700, Thailand
| | - Katika Nawapun
- Department of Obstetrics and Gynecology, Division of Maternal-Fetal Medicine, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok 10700, Thailand
| | - Thanapa Rekhawasin
- Department of Obstetrics and Gynecology, Division of Maternal-Fetal Medicine, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok 10700, Thailand
| | - Pattarawalai Talungchit
- Department of Obstetrics and Gynecology, Division of Maternal-Fetal Medicine, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok 10700, Thailand
| |
Collapse
|
5
|
Mendoza Cobaleda M, Ribera I, Maiz N, Goya M, Carreras E. Cervical modifications after pessary placement in singleton pregnancies with maternal short cervical length: 2D and 3D ultrasound evaluation. Acta Obstet Gynecol Scand 2019; 98:1442-1449. [PMID: 31102541 DOI: 10.1111/aogs.13647] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2019] [Revised: 02/19/2019] [Accepted: 05/10/2019] [Indexed: 11/29/2022]
Abstract
INTRODUCTION The use of a pessary proved to prevent preterm birth in asymptomatic women with mid-trimester short cervical length (CL); however, the precise mechanisms by which the pessary confers its benefit remain unclear. The aim of this study was to evaluate multiple cervical characteristics assessed by 2-dimensional and 3-dimensional ultrasound before and after placement of a cervical pessary to ascertain its mechanism of action. MATERIAL AND METHODS In this prospective cohort study, we assessed the cervical characteristics in singleton pregnancies with maternal short CL and compared them with matched reference women with normal CL. The variables evaluated were: CL, uterocervical angles, cervical consistency indices (cervical consistency index and CL consistency index), cervical volume and vascular indices. All variables were re-assessed immediately after pessary placement and 4-6 weeks later in all participants. Mann-Whitney U test was used to assess differences between groups and paired samples t test for comparisons in two different examinations in the same women. The aim of this study was to evaluate multiple cervical ultrasound variables before and after the placement of a cervical pessary and compare the evolution of these variables with a reference group with normal CL to better understand the device's mechanism of action. RESULTS Thirty-three women with short CL and 24 reference women with normal CL were enrolled. At the time of enrollment, gestational age and maternal baseline characteristics did not differ between groups. Immediately after pessary placement, CL increased, uterocervical angles were narrower and cervical consistency increased significantly. When the magnitude of change in cervical variables was compared over time between the reference group and the study group, median CL had increased in the study group (1.47 mm) but it had shortened in the reference group (-2.56 mm). These inverse trends were statistically significant (P = 0.006). CONCLUSIONS Cervical pessary reduces both uterocervical angles and corrects cervical angulation by pushing the cervix up toward the uterus. Maintaining the cervix aligned to the uterine axis leads to reduced cervical tissue stretch, so avoiding further cervical shortening. All these changes were present after pessary placement; however, the clinical implications of these findings remain unknown.
Collapse
Affiliation(s)
- Manel Mendoza Cobaleda
- Department of Obstetrics, Maternal Fetal Medicine Unit, Hospital Universitari Vall d'Hebron, Universitat Autònoma de Barcelona, Barcelona, Spain
| | - Irene Ribera
- Department of Obstetrics, Maternal Fetal Medicine Unit, Hospital Universitari Vall d'Hebron, Universitat Autònoma de Barcelona, Barcelona, Spain
| | - Nerea Maiz
- Department of Obstetrics, Maternal Fetal Medicine Unit, Hospital Universitari Vall d'Hebron, Universitat Autònoma de Barcelona, Barcelona, Spain
| | - Maria Goya
- Department of Obstetrics, Maternal Fetal Medicine Unit, Hospital Universitari Vall d'Hebron, Universitat Autònoma de Barcelona, Barcelona, Spain
| | - Elena Carreras
- Department of Obstetrics, Maternal Fetal Medicine Unit, Hospital Universitari Vall d'Hebron, Universitat Autònoma de Barcelona, Barcelona, Spain
| |
Collapse
|
6
|
Borghi TDF, Carvalho MHBD, Amorim Filho AGD, Martinelli S, Zugaib M, Francisco RPV. The role of three-dimensional ultrasound in pregnancies submitted to cerclage. Rev Assoc Med Bras (1992) 2018; 64:620-626. [PMID: 30365664 DOI: 10.1590/1806-9282.64.07.620] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2017] [Accepted: 12/18/2017] [Indexed: 11/21/2022] Open
Abstract
OBJECTIVE Cervical cerclage is the standard treatment for cervical incompetence (CI); however, there is still a high risk of preterm birth for women who undergo this treatment. The aim of this study was to longitudinally evaluate findings on two-dimensional transvaginal ultrasonography (2DTVUS) and three-dimensional transvaginal ultrasonography (3DTVUS) that could be related to gestational age at birth. METHODS A total of 68 pregnant women who were treated with cerclage were evaluated by 2DTVUS and 3DTVUS in the second and third trimesters of pregnancy. Log-rank tests and Cox regression analyses were used to identify significant findings related to gestational age at delivery. RESULTS A cervical length lower than 281 mm (p= 0.0083), a proximal cervical length lower than 10 mm (p= 0.0151), a cervical volume lower than 18.17 cm3 (p= 0.0152), a vascularization index (VI) under 2.153 (p= 0.0044), and a vascularization-flow index (VFI) under 0.961 (p= 0.0059) in the second trimester were all related to earlier delivery. In the third trimester, a cervical length lower than 20.4 mm (p= 0.0009), a VI over 0.54 (p= 0.0327) and a VFI over 2.275 (p= 0.0479) were all related to earlier delivery. Cervical funnelling in the second and third trimesters and proximal cervical length in the third trimester were not related to gestational age at birth. The COX regression analyses showed that cervical volume in the second trimester; FI and VFI in the third trimester were significantly associated with gestational age at birth. CONCLUSION In women treated with history-indicated cerclage or ultrasound-indicated cerclage, 2nd trimester cervical volume and 3rd trimester FI and VFI are independent significant sonographic findings associated with time to delivery.
Collapse
Affiliation(s)
- Thais da Fonseca Borghi
- Department of Obstetrics and Gynaecology, São Paulo University School of Medicine, São Paulo - SP, Brasil
| | | | | | - Silvio Martinelli
- Department of Obstetrics and Gynaecology, São Paulo University School of Medicine, São Paulo - SP, Brasil
| | - Marcelo Zugaib
- Department of Obstetrics and Gynaecology, São Paulo University School of Medicine, São Paulo - SP, Brasil
| | | |
Collapse
|
7
|
Kindinger LM, MacIntyre DA, Lee YS, Marchesi JR, Smith A, McDonald JAK, Terzidou V, Cook JR, Lees C, Israfil-Bayli F, Faiza Y, Toozs-Hobson P, Slack M, Cacciatore S, Holmes E, Nicholson JK, Teoh TG, Bennett PR. Relationship between vaginal microbial dysbiosis, inflammation, and pregnancy outcomes in cervical cerclage. Sci Transl Med 2016; 8:350ra102. [DOI: 10.1126/scitranslmed.aag1026] [Citation(s) in RCA: 107] [Impact Index Per Article: 13.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2016] [Accepted: 06/23/2016] [Indexed: 12/20/2022]
|