1
|
Lu X, Ren Y, Wan H, Xu Q, Duan S. Case report: Extravascular catheter migration in a child: A rare complication of the totally implantable venous access device. Medicine (Baltimore) 2023; 102:e32710. [PMID: 36827053 PMCID: PMC11309660 DOI: 10.1097/md.0000000000032710] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/20/2022] [Accepted: 01/02/2023] [Indexed: 02/25/2023] Open
Abstract
BACKGROUND Totally implantable venous access devices (TIVADs) are widely used to gain intermittent central venous access, such as in patients who need long-term chemotherapy, total parenteral nutrition, and long-term antibiotic treatment. At present, there are many complications associated with the use of these devices. Complete extravascular migration of TIVADs via the internal jugular vein is a very rare and potentially serious condition, especially in children. CASE PRESENTATION A 1-year-old girl needed palliative chemotherapy because of hepatoblastoma complicated by inferior vena cava thrombosis. A TIVAD was implanted through the right internal jugular vein with a routine heparin flushing tube. On the second day after the operation, a pale bloody liquid was drawn out from the device and the chest X-ray was checked to confirm that the position of the catheter was normal. On the third day after the operation, however, the patient's right respiratory sound was weakened on physical examination and auscultation. Fluoroscopy showed that the tip of the catheter was located in the right thoracic cavity, and there was a large amount of effusion in the right thoracic cavity. The pleural effusion was removed, the TIVAD was replaced again, and the child was discharged 2 days later. CONCLUSIONS Following TIVAD implantation, if abnormalities are found, in addition to chest X-ray, saline flush and echocardiography should be performed to determine the position of the catheter and rule out extravascular migration of the catheter to avoid irreparable consequences.
Collapse
Affiliation(s)
- Xuning Lu
- Heart Center, Dalian Municipal Women and Children’s Medical Center (Group), Liaoning, China
| | - Yueyi Ren
- Heart Center, Qingdao Women and Children’s Hospital, Qingdao University, Qingdao, Shandong, China
| | - Hao Wan
- Heart Center, Qingdao Women and Children’s Hospital, Qingdao University, Qingdao, Shandong, China
| | - Qiteng Xu
- Heart Center, Qingdao Women and Children’s Hospital, Qingdao University, Qingdao, Shandong, China
| | - Shuhua Duan
- Heart Center, Qingdao Women and Children’s Hospital, Qingdao University, Qingdao, Shandong, China
| |
Collapse
|
2
|
Liu Y, Du DM. Double pigtail catheter reduction for seriously displaced intravenous infusion port catheter: A case report. World J Clin Cases 2023; 11:883-887. [PMID: 36818611 PMCID: PMC9928690 DOI: 10.12998/wjcc.v11.i4.883] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/13/2022] [Revised: 12/29/2022] [Accepted: 01/10/2023] [Indexed: 02/03/2023] Open
Abstract
BACKGROUND Implanted intravenous infusion port (TIAP) is mainly used for patients who need central venous infusion and poor peripheral vascular conditions. With the advantages of easy to carry, long maintenance cycle, few complications and excellent quality of life, it has been widely used in the fields of malignant tumor chemotherapy, parenteral nutrition support and repeated blood collection. Implanted intravenous infusion port (IVAP) dislocation can have significant complications if not recognised and reinstated immediately.
CASE SUMMARY A 24-year-old man was treated with adjuvant chemotherapy for osteosarcoma. Severe displacement of IVAP catheter was found by chest X-ray examination. The IVAP cannot be used normally. Therefore, we conducted an emergency procedure to reset the catheter through double pigtail catheters, the operation was successful and the infusion port was restored.
CONCLUSION When IVAP catheter displacement cannot be reset by conventional techniques, two pigtail catheters can be successfully used instead.
Collapse
Affiliation(s)
- Yu Liu
- Department of Interventional Therapy, Shenzhen Second People’s Hospital, The First Affiliated Hospital of Shenzhen University, Shenzhen 518035, Guangdong Province, China
| | - Duan-Ming Du
- Department of Interventional Therapy, Shenzhen Second People’s Hospital, The First Affiliated Hospital of Shenzhen University, Shenzhen 518035, Guangdong Province, China
| |
Collapse
|
3
|
Saunier J, Khzam A, Yagoubi N. Impact of mechanical stress on flexible tubing used for biomedical applications: Characterization of the damages and impact on the patient's health. J Mech Behav Biomed Mater 2022; 136:105477. [PMID: 36219992 DOI: 10.1016/j.jmbbm.2022.105477] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Revised: 09/16/2022] [Accepted: 09/18/2022] [Indexed: 11/06/2022]
Abstract
Flexible tubing is a key part of a lot of medical devices used in hospital, but may be subjected to a lot of various mechanical stresses that can led to the failure or to complications for the patients. The nature and causes of these mechanical stresses were listed for peristaltic pump tubing, infusion set tubing and catheters. Their consequences in term of tubing damages and particular contamination were reported. The impact of the chemical nature of the tubing, of its size and also the impact of various parameters of the clinical acts were reviewed. Last the consequences for the patient's health were discussed.
Collapse
Affiliation(s)
- J Saunier
- Matériaux et Santé, Faculté de pharmacie, Université Paris Saclay, France.
| | - A Khzam
- Matériaux et Santé, Faculté de pharmacie, Université Paris Saclay, France
| | - N Yagoubi
- Matériaux et Santé, Faculté de pharmacie, Université Paris Saclay, France
| |
Collapse
|
4
|
Chen YB, Bao HS, Hu TT, He Z, Wen B, Liu FT, Su FX, Deng HR, Wu JN. Comparison of comfort and complications of Implantable Venous Access Port (IVAP) with ultrasound guided Internal Jugular Vein (IJV) and Axillary Vein/Subclavian Vein (AxV/SCV) puncture in breast cancer patients: a randomized controlled study. BMC Cancer 2022; 22:248. [PMID: 35248019 PMCID: PMC8898472 DOI: 10.1186/s12885-022-09228-6] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2021] [Accepted: 01/24/2022] [Indexed: 01/18/2023] Open
Abstract
Abstract
Background
Axillary vein/subclavian vein (AxV/SCV) and Internal jugular vein (IJV) are commonly used for implantable venous access port (IVAP) implantation in breast cancer patients for chemotherapy. Previous research focused on comparison of complications while patient comfort was ignored. This study aims to compare patient comfort, surgery duration and complications of IVAP implantation between IJV and AxV/SCV approaches.
Methods
Two hundred forty-eight breast cancer patients were enrolled in this randomized controlled study from August 2020 to June 2021. Patients scheduled to undergo IVAP implantation were randomly and equally assigned to receive central venous catheters with either AxV /SCV or IJV approaches. All patients received comfort assessment using a comfort scale table at day 1, day 2 and day 7 after implantation. Patient comfort, procedure time of operation as well as early complications were compared.
Results
Patient comfort was significantly better in the AxV/SCV group than that of IJV group in day 1 (P < 0.001), day 2 (P < 0.001) and day 7(P = 0.023). Procedure duration in AxV/SCV group was slightly but significantly shorter than IJV group (27.14 ± 3.29 mins vs 28.92 ± 2.54 mins, P < 0.001). More early complications occurred in AxV/SCV group than IJV group (11/124 vs 2/124, P = 0.019). No difference of complications of artery puncture, pneumothorax or subcutaneous hematoma between these two groups but significantly more catheter misplacement in AxV/SCV group than IJV group (6/124 vs 0/124, P = 0.029). Absolutely total risk of complications was rather low in both groups (8.87% in AxV/SCV group and 1.61% in IJV group).
Conclusions
Our study indicates that patients with AxV/SCV puncture have higher comfort levels than IJV puncture. AxV/SCV puncture has shorter procedure duration but higher risk of early complications, especially catheter misplacement. Both these two approaches have rather low risk of complications. Consequently, our study provides an alternative choice for breast cancer patients to reach better comfort.
Collapse
|
5
|
Lv DN, Xu HZ, Zheng LL, Chen LL, Ling Y, Ye AQ. Extravasation of chemotherapeutic drug from an implantable intravenous infusion port in a child: A case report. World J Clin Cases 2021; 9:7840-7844. [PMID: 34621835 PMCID: PMC8462233 DOI: 10.12998/wjcc.v9.i26.7840] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/18/2021] [Revised: 07/09/2021] [Accepted: 07/23/2021] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND Drug extravasation is a complication of totally implantable access port (TIAP) use and could cause tissue injury and sustained organ dysfunction. Therefore, the clinical management of children with TIAP is challenging.
CASE SUMMARY This was a case of extravasation of a chemotherapeutic drug (paclitaxel) from an implantable infusion port in a 23-mo old child. After fully evaluating the skin at the site of extravasation, the nurse continued to use the infusion port to complete the follow-up chemotherapeutic course. The skin around the infusion port was red, and showed no ulceration, swelling, or induration at discharge.
CONCLUSION Since children are more active and often noncompliant, it is necessary to appropriately train pediatric nurses caring for individuals with TIAPs, and any abnormal situation should be timely addressed.
Collapse
Affiliation(s)
- Dan-Ni Lv
- Department of Surgical Oncology, The Children’s Hospital, Zhejiang University School of Medicine, National Clinical Research Center for Child Health, Hangzhou 310052, Zhejiang Province, China
| | - Hong-Zhen Xu
- Department of Nursing, The Children’s Hospital, Zhejiang University School of Medicine, National Clinical Research Center for Child Health, Hangzhou 310052, Zhejiang Province, China
| | - Li-Li Zheng
- Department of Surgical Oncology, The Children’s Hospital, Zhejiang University School of Medicine, National Clinical Research Center for Child Health, Hangzhou 310052, Zhejiang Province, China
| | - Li-Li Chen
- Department of Surgical Oncology, The Children’s Hospital, Zhejiang University School of Medicine, National Clinical Research Center for Child Health, Hangzhou 310052, Zhejiang Province, China
| | - Yun Ling
- Department of Nursing, The Children’s Hospital, Zhejiang University School of Medicine, National Clinical Research Center for Child Health, Hangzhou 310052, Zhejiang Province, China
| | - A-Qin Ye
- Department of Surgical Oncology, The Children’s Hospital, Zhejiang University School of Medicine, National Clinical Research Center for Child Health, Hangzhou 310052, Zhejiang Province, China
| |
Collapse
|
6
|
Iguchi T, Hiraki T, Matsui Y, Tomita K, Uka M, Umakoshi N, Kajita S, Komaki T, Gobara H, Kanazawa S. Contrast examination of central venous access port implanted through internal jugular vein for evaluation of suspected complications. Jpn J Radiol 2021; 39:1103-1110. [PMID: 34021855 DOI: 10.1007/s11604-021-01142-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2021] [Accepted: 05/17/2021] [Indexed: 12/14/2022]
Abstract
PURPOSE We summarized the findings, diagnosis, and outcomes of cases for which contrast examination of central venous access ports (CV-ports) were attempted to detect complications. MATERIALS AND METHODS Fifty-seven contrast examinations were attempted for 45 patients with 46 CV-ports (median, 162 days after implantation). Contrast examination was performed due to three suspicion catheter fractures or 54 CV-port dysfunctions (combinations of an absence of blood reflux on aspiration and 9 sufficient, 21 insufficient, or 24 impossible drip infusions). RESULTS Contrast examination was successfully performed in 52 cases and revealed 45 normal findings, 5 pericatheter fibrin sheath formations, and 2 partial catheter fractures. In 23 of 45 cases with normal findings, the resistance to injection was initially mild or moderate but resolved after the CV-port was flushed slowly with heparinized saline solution. Subsequent contrast examination demonstrated normal findings. All fibrin sheath formations disappeared after thrombolytic therapy. Five cases could not undergo contrast examination due to high resistance. After contrast examination, nine of 46 CV-ports were removed or exchanged, while the use of the remaining 37 continued. CONCLUSION Contrast examination of CV-port allowed the assessment of suspected complications and early treatment.
Collapse
Affiliation(s)
- Toshihiro Iguchi
- Department of Radiology, Okayama University Medical School, 2-5-1 Shikata-cho kita-ku, Okayama, 700-8558, Japan.
| | - Takao Hiraki
- Department of Radiology, Okayama University Medical School, 2-5-1 Shikata-cho kita-ku, Okayama, 700-8558, Japan
| | - Yusuke Matsui
- Department of Radiology, Okayama University Medical School, 2-5-1 Shikata-cho kita-ku, Okayama, 700-8558, Japan
| | - Koji Tomita
- Department of Radiology, Okayama University Medical School, 2-5-1 Shikata-cho kita-ku, Okayama, 700-8558, Japan
| | - Mayu Uka
- Department of Radiology, Okayama University Medical School, 2-5-1 Shikata-cho kita-ku, Okayama, 700-8558, Japan
| | - Noriyuki Umakoshi
- Department of Radiology, Okayama University Medical School, 2-5-1 Shikata-cho kita-ku, Okayama, 700-8558, Japan
| | - Soichiro Kajita
- Department of Radiology, Okayama University Medical School, 2-5-1 Shikata-cho kita-ku, Okayama, 700-8558, Japan
| | - Toshiyuki Komaki
- Department of Radiology, Okayama University Medical School, 2-5-1 Shikata-cho kita-ku, Okayama, 700-8558, Japan
| | - Hideo Gobara
- Department of Radiology, Okayama University Medical School, 2-5-1 Shikata-cho kita-ku, Okayama, 700-8558, Japan
| | - Susumu Kanazawa
- Department of Radiology, Okayama University Medical School, 2-5-1 Shikata-cho kita-ku, Okayama, 700-8558, Japan
| |
Collapse
|
7
|
Becker F, Wurche LA, Darscht M, Pascher A, Struecker B. Totally implantable venous access port insertion via open Seldinger approach of the internal jugular vein-a retrospective risk stratification of 500 consecutive patients. Langenbecks Arch Surg 2021; 406:903-910. [PMID: 33550438 PMCID: PMC8106594 DOI: 10.1007/s00423-021-02097-w] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2020] [Accepted: 01/20/2021] [Indexed: 12/24/2022]
Abstract
PURPOSE Modern oncological treatment algorithms require a central venous device in form of a totally implantable venous access port (TIVAP). While most commonly used techniques are surgical cutdown of the cephalic vein or percutaneous puncture of the subclavian vein, there are a relevant number of patients in which an additional strategy is needed. The aim of the current study is to present a surgical technique for TIVAP implantation via an open Seldinger approach of the internal jugular vein and to characterize risk factors, associated with primary failure as well as short- (< 30 days) and long-term (> 30 days) complications. METHODS A total of 500 patients were included and followed up for 12 months. Demographic and intraoperative data and short- as well as long-term complications were extracted. Primary endpoint was TIVAP removal due to complication. Logistic regression analysis was used to analyze associated risk factors. RESULTS Surgery was primarily successful in all cases, while success was defined as functional (positive aspiration and infusion test) TIVAP which was implanted via open Seldinger approach of the jugular vein at the intended site. TIVAP removal due to complications during the 1st year occurred in 28 cases (5.6%) while a total of 4 (0.8%) intraoperative complications were noted. Rates for short- and long-term complications were 0.8% and 6.6%, respectively. CONCLUSION While the presented technique requires relatively long procedure times, it is a safe and reliable method for TIVAP implantation. Our results might help to further introduce the presented technique as a secondary approach in modern TIVAP surgery.
Collapse
Affiliation(s)
- Felix Becker
- Department of General, Visceral and Transplant Surgery, University Hospital Münster, Waldeyerstrasse 1, 48149, Münster, Germany.
| | - Lennart A Wurche
- Department of General, Visceral and Transplant Surgery, University Hospital Münster, Waldeyerstrasse 1, 48149, Münster, Germany
| | - Martina Darscht
- Department of General, Visceral and Transplant Surgery, University Hospital Münster, Waldeyerstrasse 1, 48149, Münster, Germany
| | - Andreas Pascher
- Department of General, Visceral and Transplant Surgery, University Hospital Münster, Waldeyerstrasse 1, 48149, Münster, Germany
| | - Benjamin Struecker
- Department of General, Visceral and Transplant Surgery, University Hospital Münster, Waldeyerstrasse 1, 48149, Münster, Germany
| |
Collapse
|
8
|
Klaiber U, Probst P, Hackbusch M, Jensen K, Dörr-Harim C, Hüttner FJ, Hackert T, Diener MK, Büchler MW, Knebel P. Meta-analysis of primary open versus closed cannulation strategy for totally implantable venous access port implantation. Langenbecks Arch Surg 2021; 406:587-596. [PMID: 33420832 PMCID: PMC8106576 DOI: 10.1007/s00423-020-02057-w] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2020] [Accepted: 12/09/2020] [Indexed: 12/15/2022]
Abstract
BACKGROUND There is still no reference standard for the implantation of totally implantable venous access ports (TIVAPs). A recently published multicentre randomised controlled trial (RCT) revealed a significantly greater risk of pneumothorax after closed cannulation than after an open strategy. The aim of this meta-analysis was to provide an update of the available evidence for the safety and effectiveness of primary open versus closed cannulation strategy. METHODS RCTs comparing outcomes of open cut-down of the cephalic vein and closed cannulation of the subclavian vein were sought systematically in MEDLINE, Web of Science and CENTRAL. The primary outcome was the occurrence of pneumothorax. A beta-binominal model was applied to combine the respective outcomes, and results are presented as odds ratios (OR) with 95% confidence interval (CI). RESULTS Six RCTs with a total of 1831 patients were included in final analysis. Meta-analysis showed statistically significant superiority of the open cut-down technique regarding pneumothorax (OR 0.308, 95% CI 0.122 to 0.776), but a statistically significant higher failure of the primary technique for the open cut-down technique than for closed cannulation (OR 2.364, 95% CI 1.051 to 5.315). There were no significant differences between the two procedures regarding other morbidity endpoints. CONCLUSION This meta-analysis shows a general superiority of open cut-down of the cephalic vein over closed cannulation of the subclavian vein regarding the occurrence of pneumothorax. Open cut-down should be the first-line approach for TIVAP implantation. Closed cannulation should be performed with ultrasound as second-line procedure if the open technique fails. SYSTEMATIC REVIEW REGISTRATION PROSPERO CRD42013005180.
Collapse
Affiliation(s)
- Ulla Klaiber
- Department of General, Visceral and Transplantation Surgery, University of Heidelberg, Im Neuenheimer Feld 420, 69120, Heidelberg, Germany
| | - Pascal Probst
- Department of General, Visceral and Transplantation Surgery, University of Heidelberg, Im Neuenheimer Feld 420, 69120, Heidelberg, Germany.,Study Centre of the German Surgical Society, University of Heidelberg, Heidelberg, Germany
| | - Matthes Hackbusch
- Institute of Medical Biometry and Informatics, University of Heidelberg, Heidelberg, Germany
| | - Katrin Jensen
- Institute of Medical Biometry and Informatics, University of Heidelberg, Heidelberg, Germany
| | - Colette Dörr-Harim
- Department of General, Visceral and Transplantation Surgery, University of Heidelberg, Im Neuenheimer Feld 420, 69120, Heidelberg, Germany.,Study Centre of the German Surgical Society, University of Heidelberg, Heidelberg, Germany
| | - Felix J Hüttner
- Department of General, Visceral and Transplantation Surgery, University of Heidelberg, Im Neuenheimer Feld 420, 69120, Heidelberg, Germany.,Study Centre of the German Surgical Society, University of Heidelberg, Heidelberg, Germany
| | - Thilo Hackert
- Department of General, Visceral and Transplantation Surgery, University of Heidelberg, Im Neuenheimer Feld 420, 69120, Heidelberg, Germany
| | - Markus K Diener
- Department of General, Visceral and Transplantation Surgery, University of Heidelberg, Im Neuenheimer Feld 420, 69120, Heidelberg, Germany.,Study Centre of the German Surgical Society, University of Heidelberg, Heidelberg, Germany
| | - Markus W Büchler
- Department of General, Visceral and Transplantation Surgery, University of Heidelberg, Im Neuenheimer Feld 420, 69120, Heidelberg, Germany.,Study Centre of the German Surgical Society, University of Heidelberg, Heidelberg, Germany
| | - Phillip Knebel
- Department of General, Visceral and Transplantation Surgery, University of Heidelberg, Im Neuenheimer Feld 420, 69120, Heidelberg, Germany. .,Study Centre of the German Surgical Society, University of Heidelberg, Heidelberg, Germany.
| |
Collapse
|
9
|
Arm mobilization provokes deformity of long-term indwelling ports implanted via the jugular vein. J Vasc Surg Venous Lymphat Disord 2020; 9:998-1006. [PMID: 33130283 DOI: 10.1016/j.jvsv.2020.10.010] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2020] [Accepted: 10/16/2020] [Indexed: 11/21/2022]
Abstract
BACKGROUND The incidence of totally implantable catheter fracture ranges from 0.48% to 5.00%, and these fractures represent a potentially fatal complication. The fracture mechanism of catheters implanted via the jugular vein is unclear, and whether extreme arm movements represent an additional risk factor for repetitive stress of the material remains unknown. The aim of this study was to demonstrate and classify catheter deformations caused by extreme arm mobilization and associations with changes in catheter function and displacement. METHODS We analyzed the fluoroscopy images of 60 consecutive patients undergoing long-term indwelling port implantation via the jugular vein. Three images were taken: arm in maximal abduction, maximal frontal elevation, and maximal adduction. The images were compared with an image of the remainder of the arm. We analyzed three catheter regions to classify the deformity: A, connection between catheter and reservoir; B, the catheter's subcutaneous tunnel; and C, the catheter's entrance in the jugular vein. The deformations were classified in comparative manner as follows: 0 (no changes), 1 (minor changes, new slightly curvatures with an angle of >90°), and 2 (major changes, new severe curvatures with angles of ≤90°). In each position, catheter function (injection and aspiration) and displacement of the reservoir and tip were analyzed. RESULTS Only 15% of patients did not show a deformity; 33.3% had a deformity in only one position, 47.7% in two positions, and 10% in three positions. Minor deformities were observed in 70% of patients and major deformities in 40%. Moreover, 25% of patients presented both major and minor deformities. Major deformities were observed in 25.0% of patients on maximal frontal elevation, in 23.3% on maximal adduction and in none on maximal abduction. Region B was the most affected, with 57.8% of all minor deformities and 78.1% of all major deformities. No change in function was noted in 91.7% of the catheters. Maximal arm adduction resulted in greater vertical and horizontal displacement of the catheter tip and horizontal displacement of the reservoir. Higher body mass index values were associated with major deformities. CONCLUSIONS Maximal frontal elevation and maximal adduction were associated with major catheter deformities, and the subcutaneous tunnel region was the most deformed catheter region. An association between major catheter deformity and high body mass index was noted; in contrast, no association between the severity of catheter deformity, tip or reservoir displacement, or worsened functioning was observed.
Collapse
|
10
|
Jiang M, Li CL, Pan CQ, Cui XW, Dietrich CF. Risk of venous thromboembolism associated with totally implantable venous access ports in cancer patients: A systematic review and meta-analysis. J Thromb Haemost 2020; 18:2253-2273. [PMID: 32479699 DOI: 10.1111/jth.14930] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2020] [Revised: 05/07/2020] [Accepted: 05/19/2020] [Indexed: 12/12/2022]
Abstract
BACKGROUND Totally implantable venous access ports (TIVAPs) for chemotherapy are associated with venous thromboembolism (VTE). We aimed to quantify the incidence of TIVAP-associated VTE and compare it with external central venous catheters (CVCs) in cancer patients through a meta-analysis. METHODS Studies reporting on VTE risk associated with TIVAP were retrieved from medical literature databases. In publications without a comparison group, the pooled incidence of TIVAP-related VTE was calculated. For studies comparing TIVAPs with external CVCs, odds ratios (ORs) were calculated to assess the risk of VTE. RESULTS In total, 80 studies (11 with a comparison group and 69 without) including 39 148 patients were retrieved. In the noncomparison studies, the overall symptomatic VTE incidence was 2.76% (95% confidence interval [CI]: 2.24-3.28), and 0.08 (95 CI: 0.06-0.10) per 1000 catheter-days. This risk was highest when TIVAPs were inserted via the upper-extremity vein (3.54%, 95% CI: 2.94-4.76). Our meta-analysis of the case-control studies showed that TIVAPs were associated with a decreased risk of VTE compared with peripherally inserted central catheters (OR = 0.20, 95% CI: 0.09-0.43), and a trend for lower VTE risk compared with Hickman catheters (OR = 0.75, 95% CI: 0.37-1.50). Meta-regression models suggested that regional difference may significantly impact on the incidence of VTE associated with TIVAPs. CONCLUSIONS Current evidence suggests that the cancer patients with TIVAP are less likely to develop VTE compared with external CVCs. This should be considered when choosing the indwelling intravenous device for chemotherapy. However, more attention should be paid when choosing upper-extremity veins as the insertion site.
Collapse
Affiliation(s)
- Meng Jiang
- Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Chang-Li Li
- Department of Geratology, Hubei Provincial Hospital of Integrated Chinese and Western medicine, Wuhan, Hubei Province, China
| | - Chun-Qiu Pan
- Department of Emergency Medicine, Nanfang Hospital, Southern Medical University, Guangzhou, China
| | - Xin-Wu Cui
- Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | | |
Collapse
|
11
|
Lenz H, Myre K, Draegni T, Dorph E. A Five-Year Data Report of Long-Term Central Venous Catheters Focusing on Early Complications. Anesthesiol Res Pract 2019; 2019:6769506. [PMID: 31885552 PMCID: PMC6925808 DOI: 10.1155/2019/6769506] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2019] [Revised: 11/08/2019] [Accepted: 11/20/2019] [Indexed: 11/29/2022] Open
Abstract
BACKGROUND Long-term venous access has become the standard practice for the administration of chemotherapy, fluid therapy, antibiotics, and parenteral nutrition. The most commonly used methods are percutaneous puncture of the subclavian and internal jugular veins using the Seldinger technique or surgical cutdown of the cephalic vein. METHODS This study is based on a quality registry including all long-term central venous catheter insertion procedures performed in patients >18 years at our department during a five-year period. The following data were registered: demographic data, main diagnosis and indications for the procedure, preoperative blood samples, type of catheter, the venous access used, and the procedure time. In addition, procedural and early postoperative complications were registered: unsuccessful procedures, malpositioned catheters, pneumothorax, hematoma complications, infections, nerve injuries, and wound ruptures. The Seldinger technique using anatomical landmarks at the left subclavian vein was the preferred access. Fluoroscopy was not used. RESULTS One thousand one hundred and one procedures were performed. In eight (0.7%) cases, the insertion of a catheter was not possible, 23 (2.1%) catheters were incorrectly positioned, twelve (1.1%) patients developed pneumothorax, nine (0.8%) developed hematoma, and three (0.27%) developed infection postoperatively. One (0.1%) patient suffered nerve injury, which totally recovered. No wound ruptures were observed. CONCLUSIONS We have a high success rate of first-attempt insertions compared with other published data, as well as an acceptable and low rate of pneumothorax, hematoma, and infections. However, the number of malpositioned catheters was relatively high. This could probably have been avoided with routine use of fluoroscopy during the procedure.
Collapse
Affiliation(s)
- Harald Lenz
- Oslo University Hospital, Division of Emergencies and Critical Care, Department of Anaesthesiology, Postbox 4950 Nydalen, 0424 Oslo, Norway
| | - Kirsti Myre
- Oslo University Hospital, Division of Emergencies and Critical Care, Department of Anaesthesiology, Postbox 4950 Nydalen, 0424 Oslo, Norway
| | - Tomas Draegni
- Oslo University Hospital, Division of Emergencies and Critical Care, Department of Research and Development, Postbox 4950 Nydalen, 0424 Oslo, Norway
| | - Elizabeth Dorph
- Oslo University Hospital, Division of Emergencies and Critical Care, Department of Anaesthesiology, Postbox 4950 Nydalen, 0424 Oslo, Norway
| |
Collapse
|
12
|
Tsuruta S, Goto Y, Miyake H, Nagai H, Yoshioka Y, Yuasa N, Takamizawa J. Late complications associated with totally implantable venous access port implantation via the internal jugular vein. Support Care Cancer 2019; 28:2761-2768. [PMID: 31724073 DOI: 10.1007/s00520-019-05122-3] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2019] [Accepted: 10/06/2019] [Indexed: 01/17/2023]
Abstract
PURPOSE Several studies have analyzed late complications associated with totally implantable venous access ports (TIVAP) implantation via the internal jugular vein (IJV); however, the reported results are inconclusive. The aim of the study is to elucidate the characteristics and risk factors of late complications associated with TIVAP implantation via the IJV. METHODS The study included 482 patients who underwent TIVAP implantation for long-term chemotherapy and/or nutritional support between April 2012 and December 2017. Most patients (95.2%) had malignant diseases. Events requiring TIVAP removal were defined as TIVAP-related complications. RESULTS The median TIVAP and global follow-ups were 319 days (IQR 152-661) and 218,971 catheter days, respectively. The 3-year cumulative TIVAP availability rate was 70%. There were 44 complications (incidence of 9.1%; 0.201 complications/1000 catheter days). Infectious, catheter-related, and port-related complications occurred in 21, 14, and 9 patients, respectively with infectious complications occurring earlier and more frequently than catheter- and port-related complications. Multivariate analysis revealed that age < 65 years and presence of non-gastrointestinal diseases were significant unfavorable factors for TIVAP-related complications. Patients with 1 and 2 of these factors had an elevated risk (2.2 and 5.4 times, respectively) compared with those without. CONCLUSIONS Among the late complications associated with TIVAP implantation via the IJV, infectious complications occur earlier and more frequently than catheter- and port-related complications. Patients with an age < 65 years and having non-gastrointestinal diseases have a significantly high risk of TIVAP-related complications.
Collapse
Affiliation(s)
- Shigeaki Tsuruta
- Department of Surgery, Japanese Red cross Nagoya First Hospital, 3-35 Michishita-cho, Nakamura-ku, Nagoya, 453-8511, Japan
| | - Yasutomo Goto
- Department of Surgery, Japanese Red cross Nagoya First Hospital, 3-35 Michishita-cho, Nakamura-ku, Nagoya, 453-8511, Japan
| | - Hideo Miyake
- Department of Surgery, Japanese Red cross Nagoya First Hospital, 3-35 Michishita-cho, Nakamura-ku, Nagoya, 453-8511, Japan
| | - Hidemasa Nagai
- Department of Surgery, Japanese Red cross Nagoya First Hospital, 3-35 Michishita-cho, Nakamura-ku, Nagoya, 453-8511, Japan
| | - Yuichiro Yoshioka
- Department of Surgery, Japanese Red cross Nagoya First Hospital, 3-35 Michishita-cho, Nakamura-ku, Nagoya, 453-8511, Japan
| | - Norihiro Yuasa
- Department of Surgery, Japanese Red cross Nagoya First Hospital, 3-35 Michishita-cho, Nakamura-ku, Nagoya, 453-8511, Japan.
| | - Junichi Takamizawa
- Department of Laboratory Medicine, Japanese Red Cross Nagoya First Hospital, 3-35 Michishita-cho, Nakamura-ku, Nagoya, 453-8511, Japan
| |
Collapse
|
13
|
Rhu J, Jun KW, Song BJ, Sung K, Cho J. Cephalic vein approach for the implantable central venous access: A retrospective review of the single institution's experiences; Cohort Study. Medicine (Baltimore) 2019; 98:e18007. [PMID: 31725671 PMCID: PMC6867776 DOI: 10.1097/md.0000000000018007] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
Long-term venous access is usually required in patients receiving chemotherapy. We hypothesized that, out of the various central line approach techniques, the cephalic vein cut-down technique can be a safe and simple alternative in terms of surgical safety, feasibility, cost-effectiveness, and functional outcomes.We retrospectively reviewed the medical records of 569 patients who underwent implantable central venous access between January 2012 and December 2014 at our hospital.We classified our cohort according to access routes, as follows: 230 patients underwent subclavian vein access, 134 patients underwent internal jugular vein access, 25 patients underwent external jugular vein access, and 119 patients underwent cephalic vein access. The cephalic vein group had a significantly longer operation time than the subclavian group (P < .01); however, there was no difference in operation time between the internal jugular vein and cephalic vein groups (P = .59). The procedure-related complications and functional outcomes of the implanted venous port during chemotherapy were comparable between the cephalic group and other groups. Additionally, body mass index, operation time, and age did not correlate with catheter dysfunction in the multivariate logistic regression analysis (P = .53; P = .66; P = .19, respectively).We suggest that a cut-down central venous catheter insertion through the cephalic vein can be performed easily and safely with no differences in surgical and clinical outcomes compared to those of conventional percutaneous approaches. Moreover, the cephalic vein approach requires no specialized equipment, including percutaneous vascular kits, tunneling instruments, and intraoperative ultrasonography. Therefore, this technique might incur less medical expenses than conventional approaches and would be helpful for both patients and surgeons.
Collapse
|
14
|
Velioğlu Y, Yüksel A, Sınmaz E. Complications and management strategies of totally implantable venous access port insertion through percutaneous subclavian vein. TURK GOGUS KALP DAMAR CERRAHISI DERGISI 2019; 27:499-507. [PMID: 32082916 PMCID: PMC7018162 DOI: 10.5606/tgkdc.dergisi.2019.17972] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/25/2019] [Accepted: 07/31/2019] [Indexed: 12/26/2022]
Abstract
BACKGROUND The aim of this study was to present clinical characteristics, peri-procedural outcomes, early and late complications, and management strategies in patients undergoing totally implantable venous access port insertion through percutaneous subclavian vein. METHODS A total of 2,084 port devices were inserted to 2,000 cancer patients (1,066 males, 934 females; mean age 58.4±12.7 years; range, 18 to 88 years) through subclavian vein using percutaneous landmark method between March 2012 and June 2018. Medical data including demographic features, primary diagnosis, technical success, procedural time, duration of device use, reasons for the device removal, and early and late complications were retrospectively analyzed. RESULTS The most common type of cancer was colon cancer in males and breast cancer in females. Technical success rate of the procedure was 98.5%. Right subclavian vein was accessed in the majority of patients (92.4%). Early complications including inadvertent arterial puncture, catheter malposition, superficial hematoma, and pneumothorax occurred in 143 patients (6.9%), while late complications including infection, catheter occlusion, venous thrombosis, wound problems, catheter migration and embolization and pinch-off syndrome was developed in 118 patients (5.7%). Inadvertent arterial puncture in 63 patients (3%) was the most common early complication, while infection in 44 patients (2.1%) was the most common late complication. A total of 192 devices were removed due to the completion of chemotherapy or development of complications. CONCLUSION Our study confirmed the safety and tolerability of totally implantable venous access port insertion through percutaneous subclavian vein with high technical success and low complication rates.
Collapse
Affiliation(s)
- Yusuf Velioğlu
- Department of Cardiovascular Surgery, Abant İzzet Baysal University Faculty of Medicine, Bolu, Turkey
| | - Ahmet Yüksel
- Department of Cardiovascular Surgery, Abant İzzet Baysal University Faculty of Medicine, Bolu, Turkey
| | - Emrah Sınmaz
- Department of Thoracic Surgery, Bursa Ali Osman Sönmez Oncology Hospital
| |
Collapse
|
15
|
Matsunari K, Watanabe K, Hishizume N, Fujisawa H. Influence of venipuncture point and port chamber site on the risk of catheter fracture in right internal jugular port placements. J Vasc Access 2019; 20:666-671. [PMID: 30973300 DOI: 10.1177/1129729819839614] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
BACKGROUND For subcutaneously implanted central venous ports, some complications due to prolonged placement have been reported. We investigated the appropriate puncture points and port placement sites to prevent catheter fracture in right internal jugular port placement. METHODS This retrospective study included 709 patients who underwent right internal jugular vein puncture and port implantation in the right precordium between 1 May 2012 and 31 March 2018. The cases were divided into undamaged catheter group and damaged catheter group comprising normal and fracture cases, respectively. The catheter angle, distance from the clavicle, tip position, and curvature radius were measured from fluoroscopic images obtained at the time of implantation. The t-test was used in statistical analysis. RESULTS Median angles were 91.6° in the undamaged catheter group and 58.0° in the damaged catheter group. Median distances were 26.0 mm in the undamaged catheter group and 36.6 mm in the damaged catheter group. Median tip positions were 51.6 mm in the undamaged catheter group and 37.5 mm in the damaged catheter group. Median curvature radii were 9.2 R in the undamaged catheter group and 7.1 R in the damaged catheter group. Significant differences were found in the angle, height, and curvature radius between the two groups. CONCLUSION Our results indicate that a venipuncture as close to the clavicle as possible (less than 3 cm) and a gentle catheter curve (close to 90° angle) are associated with a lower risk of catheter fracture.
Collapse
Affiliation(s)
- Kazuya Matsunari
- Department of Radiology, Showa University Northern Yokohama Hospital, Yokohama, Japan
| | - Kota Watanabe
- Department of Radiology, Showa University Northern Yokohama Hospital, Yokohama, Japan
| | - Norihiro Hishizume
- Department of Radiology, Showa University Northern Yokohama Hospital, Yokohama, Japan
| | - Hidefumi Fujisawa
- Department of Radiology, Showa University Northern Yokohama Hospital, Yokohama, Japan
| |
Collapse
|
16
|
Bademler S, Üçüncü M, Yıldırım İ, Karanlık H. Risk factors for complications in cancer patients with totally implantable access ports: A retrospective study and review of the literature. J Int Med Res 2018; 47:702-709. [PMID: 30442047 PMCID: PMC6381497 DOI: 10.1177/0300060518808167] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023] Open
Abstract
OBJECTIVES To analyze the risk factors for complications associated with the use of totally implantable access ports (TIAPs) in cancer patients. METHODS Data for 2,713 cancer patients who received a TIAP between January 2010 and September 2016 at a single center were analyzed retrospectively. RESULTS The average age of the patients was 54.2 ± 9.92 years, and 1,247 (47.5%) were women. The right subclavian vein was the preferred insertion site. Seventy-seven patients developed early complications and 50 developed late complications. The incidence of complications increased as the number of punctures increased. Percutaneous intervention increased the risk of complications during port insertion, but age, sex, body mass index, and the use of physiological saline solution instead of heparin for washing after port insertion did not increase the risk. The use of ultrasonography during insertion reduced the risk of complications. CONCLUSIONS Various factors may affect the function of TIAPs in cancer patients both during insertion and follow-up. Age, sex, body mass index, and the use of physiological saline solution for washing did not affect the incidence of complications, but the use of ultrasonography during insertion did affect the complication rate.
Collapse
Affiliation(s)
- Süleyman Bademler
- 1 Department of General Surgery, Faculty of Medicine, Istanbul University, Istanbul, Turkey
| | - Muhammed Üçüncü
- 2 Institute of Health Science, Istanbul Gelisim University, Istanbul, Turkey
| | - İlknur Yıldırım
- 3 Department of Anesthesiology, Institute of Oncology, Istanbul University, Istanbul, Turkey
| | - Hasan Karanlık
- 4 Department of General Surgery, Institute of Oncology, Istanbul University, Istanbul, Turkey
| |
Collapse
|
17
|
Venkatesan VK, McHenry ZD, Ertel AE, Ahmad SA, Sussman JJ, Hanseman D, Shah SA, Abbott DE. Programmatic change leads to enhanced resource utilization and efficiency in port placement. J Surg Res 2018; 229:294-301. [PMID: 29937005 DOI: 10.1016/j.jss.2018.04.030] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2017] [Revised: 04/02/2018] [Accepted: 04/13/2018] [Indexed: 12/17/2022]
Abstract
BACKGROUND Central venous port (CVP) placement is performed by a variety of surgeons in different subspecialties, and our previous work suggests that individual surgeons-regardless of training-are the strongest predictor of outcomes. We sought to prospectively evaluate a programmatic shift toward a resource-conscious, patient-focused algorithm for this common and simple surgical procedure. MATERIALS AND METHODS After implementation of a systems-level program for efficient CVP placement, 78 CVPs were placed by a single surgeon. Primary outcomes were procedure time, total operating room (OR) time, total facility time, and procedure-related complications. These prospective data were compared with retrospective cohorts of surgically placed and interventional radiology-placed CVP. Demographic data were analyzed by chi-square analysis, whereas time data were analyzed by the Wilcoxon rank-sum test. RESULTS The programmatic delivery (prospective) set showed significantly shorter procedural (median 16 min versus 26-40, P <0.05), OR times (median 36 min versus 46-70, P <0.05), and facility times (median 235 min versus 299-319, P <0.05) except for the interventional radiology facility time (median 187 versus 235, P <0.05). The range of OR time savings with the prospective versus comparison groups was 10-34 min, representing 22%-49% reductions in OR time (P <0.05). Complication rates were not significantly different (P = 0.13). CONCLUSIONS Through a programmatic change emphasizing efficiency and patient-centered outcomes, procedural/OR/facility time can be reduced greatly without changing complication rates. These data provide compelling evidence that common and ostensibly simple operative procedures can be substantially improved upon with thoughtful, data-driven systems-level enhancements.
Collapse
Affiliation(s)
- Vijay K Venkatesan
- Cincinnati Research on Outcomes and Safety in Surgery (CROSS), Department of Surgery, University of Cincinnati School of Medicine, Cincinnati, Ohio; Medical College of Georgia, Augusta University, Augusta, Georgia
| | - Zachary D McHenry
- Cincinnati Research on Outcomes and Safety in Surgery (CROSS), Department of Surgery, University of Cincinnati School of Medicine, Cincinnati, Ohio
| | - Audrey E Ertel
- Cincinnati Research on Outcomes and Safety in Surgery (CROSS), Department of Surgery, University of Cincinnati School of Medicine, Cincinnati, Ohio
| | - Syed A Ahmad
- Cincinnati Research on Outcomes and Safety in Surgery (CROSS), Department of Surgery, University of Cincinnati School of Medicine, Cincinnati, Ohio
| | - Jeffrey J Sussman
- Cincinnati Research on Outcomes and Safety in Surgery (CROSS), Department of Surgery, University of Cincinnati School of Medicine, Cincinnati, Ohio
| | - Dennis Hanseman
- Cincinnati Research on Outcomes and Safety in Surgery (CROSS), Department of Surgery, University of Cincinnati School of Medicine, Cincinnati, Ohio
| | - Shimul A Shah
- Cincinnati Research on Outcomes and Safety in Surgery (CROSS), Department of Surgery, University of Cincinnati School of Medicine, Cincinnati, Ohio
| | - Daniel E Abbott
- Department of Surgery, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin.
| |
Collapse
|
18
|
Fujimoto K, Kasai H, Sugiura T, Tatsumi K. Four-dimensional CT-guided transcatheter removal of a fractured migrated catheter of a totally implantable venous access port. BMJ Case Rep 2017; 2017:bcr-2017-221445. [PMID: 28765192 DOI: 10.1136/bcr-2017-221445] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
Patients undergoing chemotherapy usually undergo placement of a totally implantable venous access port (TIVAP), but TIVAP catheter fracture is rare. We encountered a case where flushing the TIVAP catheter became impossible because of resistance. A 61-year-old-woman underwent TIVAP placement. Although a chest X-ray revealed the fractured catheter had migrated into the right hilar area, the timing of the fracture was unclear. Four-dimensional computed tomography (4D-CT) showed that the tip of the fractured catheter was located at the anterior segmental artery of the right upper lobe and was immobile, with the remaining portion flapping with the blood flow. Transcatheter removal of the migrated catheter was judged to be possible and was performed successfully. 4D-CT may be useful as an appropriate approach in transcatheter removal of a migrated fractured catheter.
Collapse
Affiliation(s)
- Kazushi Fujimoto
- Department of Medicine, School of Medicine, Chiba University, Chiba, Chiba, Japan
| | - Hajime Kasai
- Department of Respirology, Graduate School of Medicine, Chiba University, Chiba, Chiba, Japan
| | - Toshihiko Sugiura
- Department of Respirology, Graduate School of Medicine, Chiba University, Chiba, Chiba, Japan
| | - Koichiro Tatsumi
- Department of Respirology, Graduate School of Medicine, Chiba University, Chiba, Chiba, Japan
| |
Collapse
|
19
|
Matsushima H, Adachi T, Iwata T, Hamada T, Moriuchi H, Yamashita M, Kitajima T, Okubo H, Eguchi S. Analysis of the Outcomes in Central Venous Access Port Implantation Performed by Residents via the Internal Jugular Vein and Subclavian Vein. JOURNAL OF SURGICAL EDUCATION 2017; 74:443-449. [PMID: 27932306 DOI: 10.1016/j.jsurg.2016.11.005] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/08/2016] [Revised: 11/08/2016] [Accepted: 11/15/2016] [Indexed: 06/06/2023]
Abstract
OBJECTIVE The central venous access port (CVAP) has played an important role in the safe administration of chemotherapy and parenteral nutrition. The aim of the present study was to clarify the optimal access vein for CVAP implantation when performed by residents rather than attending surgeons. METHODS A consecutive cases of CVAP implantation via the subclavian vein (SV) using a landmark-guided technique or via the internal jugular vein (JV) using an ultrasound-guided technique were divided into 2 groups according to whether the intervention was performed by a resident or an attending surgeon. Early and late complications were compared retrospectively between the 2 groups, and the outcomes of the CVAPs were compared between those implanted via the SV and those implanted via the JV in resident group. RESULTS A total of 207 cases of CVAP implantation were performed. Overall, 114 implantations were performed by residents, and another 93 implantations were performed by attending surgeons. Early complications were seen more frequently in the resident group (6.1%) than in the attending-surgeon group (1.1%), but the difference was not significant. No differences in operating time or late complications were observed between the 2 groups. In the resident group, CVAP implantations via the JV using the ultrasound-guided technique were associated with a shorter operating time compared with the SV approach. CONCLUSIONS Residents can perform CVAP implantations safely using both the SV and JV approaches. However, the JV approach using an ultrasound-guided technique can be performed in less time than the SV approach.
Collapse
Affiliation(s)
| | - Tomohiko Adachi
- Department of Surgery, Nagasaki Rosai Hospital, Sasebo, Japan
| | - Toru Iwata
- Department of Surgery, Nagasaki Rosai Hospital, Sasebo, Japan
| | - Takashi Hamada
- Department of Surgery, Nagasaki Rosai Hospital, Sasebo, Japan
| | - Hiroki Moriuchi
- Department of Surgery, Nagasaki Rosai Hospital, Sasebo, Japan
| | | | - Tomoo Kitajima
- Department of Surgery, Nagasaki Rosai Hospital, Sasebo, Japan
| | - Hitoshi Okubo
- Department of Surgery, Nagasaki Rosai Hospital, Sasebo, Japan
| | - Susumu Eguchi
- Department of Surgery, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan
| |
Collapse
|
20
|
|
21
|
Wu S, Huang J, Jiang Z, Huang Z, Ouyang H, Deng L, Lin W, Guo J, Zeng W. Internal jugular vein versus subclavian vein as the percutaneous insertion site for totally implantable venous access devices: a meta-analysis of comparative studies. BMC Cancer 2016; 16:747. [PMID: 27658952 PMCID: PMC5034477 DOI: 10.1186/s12885-016-2791-2] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2016] [Accepted: 09/16/2016] [Indexed: 02/06/2023] Open
Abstract
Background A totally implantable venous access device (TIVAD) provides reliable, long-term vascular access and improves patients’ quality of life. The wide use of TIVADs is associated with important complications. A meta-analysis was undertaken to compare the internal jugular vein (IJV) with the subclavian vein (SCV) as the percutaneous access site for TIVAD to determine whether IJV has any advantages. Methods All randomized controlled trials (RCTs) and cohort studies assessing the two access sites, IJV and SCV, were retrieved from PubMed, Web of Science, Embase, and OVID EMB Reviews from their inception to December 2015. Random-effects models were used in all analyses. The endpoints evaluated included TIVAD-related infections, catheter-related thrombotic complications, and major mechanical complications. Results Twelve studies including 3905 patients published between 2008 and 2015, were included. Our meta-analysis showed that incidences of TIVAD-related infections (odds ratio [OR] 0.71, 95 % confidence interval [CI] 0.48–1.04, P = 0.081) and catheter-related thrombotic complications (OR 0.76, 95 % CI 0.38–1.51, P = 0.433) were not significantly different between the two groups. However, compared with SCV, IJV was associated with reduced risks of total major mechanical complications (OR 0.38, 95 % CI 0.24–0.61, P < 0.001). More specifically, catheter dislocation (OR 0.43, 95 % CI 0.22–0.84, P = 0.013) and malfunction (OR 0.42, 95 % CI 0.28–0.62, P < 0.001) were more prevalent in the SCV than in the IJV group; however, the risk of catheter fracture (OR 0.47, 95 % CI 0.21–1.05, P = 0.065) were not significantly different between the two groups. Sensitivity analyses using fixed-effects models showed a decreased risk of catheter fracture in the IJV group. Conclusion The IJV seems to be a safer alternative to the SCV with lower risks of total major mechanical complications, catheter dislocation, and malfunction. However, a large-scale and well-designed RCT comparing the complications of each access site is warranted before the IJV site can be unequivocally recommended as a first choice for percutaneous implantation of a TIVAD.
Collapse
Affiliation(s)
- Shaoyong Wu
- Department of Anesthesiology, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, 651 Dongfeng East Road, Guangzhou, Guangdong, 510060, People's Republic of China
| | - Jingxiu Huang
- Department of Anesthesiology, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, 651 Dongfeng East Road, Guangzhou, Guangdong, 510060, People's Republic of China
| | - Zongming Jiang
- Department of Anesthesiology, Shaoxing People's Hospital (Shaoxing Hospital of Zhejiang University), Shaoxing, Zhejiang, China
| | - Zhimei Huang
- Department of Minimal Invasive Intervention, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Guangzhou, China
| | - Handong Ouyang
- Department of Anesthesiology, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, 651 Dongfeng East Road, Guangzhou, Guangdong, 510060, People's Republic of China
| | - Li Deng
- Department of Anesthesiology, The First Affiliated Hospital of Soochow University, Suzhou, Jiangsu, China
| | - Wenqian Lin
- Department of Anesthesiology, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, 651 Dongfeng East Road, Guangzhou, Guangdong, 510060, People's Republic of China
| | - Jin Guo
- Department of Anesthesiology, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, 651 Dongfeng East Road, Guangzhou, Guangdong, 510060, People's Republic of China
| | - Weian Zeng
- Department of Anesthesiology, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, 651 Dongfeng East Road, Guangzhou, Guangdong, 510060, People's Republic of China.
| |
Collapse
|
22
|
Tagliari AP, Staub FL, Guimarães JR, Migliavacca A, Mossmann DDF. Evaluation of three different techniques for insertion of totally implantable venous access device: A randomized clinical trial. J Surg Oncol 2015; 112:56-9. [DOI: 10.1002/jso.23962] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2015] [Revised: 06/09/2015] [Accepted: 06/10/2015] [Indexed: 12/21/2022]
Affiliation(s)
- Ana Paula Tagliari
- Department of General Surgery of Hospital de Cl; í; nicas de Porto Alegre; Porto Alegre, Rio Grande do Sul; Brazil
| | - Fernanda Luiza Staub
- Federal University of Rio Grande do Sul; Porto Alegre, Rio Grande do Sul; Brazil
| | - José Ricardo Guimarães
- Department of General Surgery of Hospital de Cl; í; nicas de Porto Alegre; Porto Alegre, Rio Grande do Sul; Brazil
| | - Alceu Migliavacca
- Department of General Surgery of Hospital de Cl; í; nicas de Porto Alegre; Porto Alegre, Rio Grande do Sul; Brazil
| | - Diego da Fonseca Mossmann
- Department of General Surgery of Hospital de Cl; í; nicas de Porto Alegre; Porto Alegre, Rio Grande do Sul; Brazil
| |
Collapse
|