1
|
Elbow joint loads during simulated activities of daily living: implications for formulating recommendations after total elbow arthroplasty. J Shoulder Elbow Surg 2024; 33:145-155. [PMID: 37689102 DOI: 10.1016/j.jse.2023.07.042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/22/2023] [Revised: 07/21/2023] [Accepted: 07/31/2023] [Indexed: 09/11/2023]
Abstract
BACKGROUND Overloading of the elbow joint prosthesis following total elbow arthroplasty can lead to implant failure. Joint moments during daily activities are not well contextualized for a prosthesis's failure limits, and the effect of the current postoperative instruction on elbow joint loading is unclear. This study investigates the difference in elbow joint moments between simulated daily tasks and between flexion-extension, pronation-supination, and varus-valgus movement directions. Additionally, the effect of the current postoperative instruction on elbow joint load is examined. METHODS Nine healthy participants (age 45.8 ± 17 years, 3 males) performed 8 tasks; driving a car, opening a door, rising from a chair, lifting, sliding, combing hair, drinking, emptying cup, without and with the instruction "not lifting more than 1 kg." Upper limb kinematics and hand contact forces were measured. Elbow joint angles and net moments were analyzed using inverse dynamic analysis, where the net moments are estimated from movement data and external forces. RESULTS Peak elbow joint moments differed significantly between tasks (P < .01) and movement directions (P < .01). The most and least demanding tasks were, rising from a chair (13.4 Nm extension, 5.0 Nm supination, and 15.2 Nm valgus) and sliding (4.3 Nm flexion, 1.7 Nm supination, and 2.6 Nm varus). Net moments were significantly reduced after instruction only in the chair task (P < .01). CONCLUSION This study analyzed elbow joint moments in different directions during daily tasks. The outcomes question whether postoperative instruction can lead to decreasing elbow loads. Future research might focus on reducing elbow loads in the flexion-extension and varus-valgus directions.
Collapse
|
2
|
[Complaints after total joint arthroplasty: caused by infection or metal hypersensitivity?]. NEDERLANDS TIJDSCHRIFT VOOR GENEESKUNDE 2023; 166. [PMID: 36928687] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 03/18/2023]
Abstract
Besides periprosthetic joint infection, metal hypersensitivity should be considered when complaints persist after total joint arthroplasty. To date, there is no consensus on the diagnosis, and believers and non-believers of metal hypersensitivity exist. The pathogenesis of metal hypersensitivity is complex and involves a type-4 delayed hypersensitivity reaction with both a cutaneous and systemic response. It is unclear if complaints after total joint arthroplasty (after eliminating other causes) are caused by metal hypersensitivity. Furthermore, it is not known whether sensitization is a cause or a consequence of complaints after total joint arthroplasty. Currently, the patch test is the best screening test to diagnose metal hypersensitivity, but the accuracy has not been defined. We present a female patient with a painful left elbow three years after total elbow replacement. Because of the increasing volume of total joint prostheses, we aim to create awareness for metal hypersensitivity and the according diagnostic dilemmas.
Collapse
|
3
|
[Complaints after total joint arthroplasty: caused by infection or metal hypersensitivity?]. NEDERLANDS TIJDSCHRIFT VOOR GENEESKUNDE 2023; 167. [PMID: 36943166] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Subscribe] [Scholar Register] [Indexed: 03/23/2023]
Abstract
Besides periprosthetic joint infection, metal hypersensitivity should be considered when complaints persist after total joint arthroplasty. To date, there is no consensus on the diagnosis, and believers and non-believers of metal hypersensitivity exist. The pathogenesis of metal hypersensitivity is complex and involves a type-4 delayed hypersensitivity reaction with both a cutaneous and systemic response. It is unclear if complaints after total joint arthroplasty (after eliminating other causes) are caused by metal hypersensitivity. Furthermore, it is not known whether sensitization is a cause or a consequence of complaints after total joint arthroplasty. Currently, the patch test is the best screening test to diagnose metal hypersensitivity, but the accuracy has not been defined. We present a female patient with a painful left elbow three years after total elbow replacement. Because of the increasing volume of total joint prostheses, we aim to create awareness for metal hypersensitivity and the according diagnostic dilemmas.
Collapse
|
4
|
LOFIT (Lifestyle front Office For Integrating lifestyle medicine in the Treatment of patients): a novel care model towards community-based options for lifestyle change-study protocol. Trials 2023; 24:114. [PMID: 36803271 PMCID: PMC9936650 DOI: 10.1186/s13063-022-06960-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2022] [Accepted: 11/25/2022] [Indexed: 02/19/2023] Open
Abstract
BACKGROUND A healthy lifestyle is indispensable for the prevention of noncommunicable diseases. However, lifestyle medicine is hampered by time constraints and competing priorities of treating physicians. A dedicated lifestyle front office (LFO) in secondary/tertiary care may provide an important contribution to optimize patient-centred lifestyle care and connect to lifestyle initiatives from the community. The LOFIT study aims to gain insight into the (cost-)effectiveness of the LFO. METHODS Two parallel pragmatic randomized controlled trials will be conducted for (cardio)vascular disorders (i.e. (at risk of) (cardio)vascular disease, diabetes) and musculoskeletal disorders (i.e. osteoarthritis, hip or knee prosthesis). Patients from three outpatient clinics in the Netherlands will be invited to participate in the study. Inclusion criteria are body mass index (BMI) ≥25 (kg/m2) and/or smoking. Participants will be randomly allocated to either the intervention group or a usual care control group. In total, we aim to include 552 patients, 276 in each trial divided over both treatment arms. Patients allocated to the intervention group will participate in a face-to-face motivational interviewing (MI) coaching session with a so-called lifestyle broker. The patient will be supported and guided towards suitable community-based lifestyle initiatives. A network communication platform will be used to communicate between the lifestyle broker, patient, referred community-based lifestyle initiative and/or other relevant stakeholders (e.g. general practitioner). The primary outcome measure is the adapted Fuster-BEWAT, a composite health risk and lifestyle score consisting of resting systolic and diastolic blood pressure, objectively measured physical activity and sitting time, BMI, fruit and vegetable consumption and smoking behaviour. Secondary outcomes include cardiometabolic markers, anthropometrics, health behaviours, psychological factors, patient-reported outcome measures (PROMs), cost-effectiveness measures and a mixed-method process evaluation. Data collection will be conducted at baseline, 3, 6, 9 and 12 months follow-up. DISCUSSION This study will gain insight into the (cost-)effectiveness of a novel care model in which patients under treatment in secondary or tertiary care are referred to community-based lifestyle initiatives to change their lifestyle. TRIAL REGISTRATION ISRCTN ISRCTN13046877 . Registered 21 April 2022.
Collapse
|
5
|
Elbow joint biomechanics during ADL focusing on total elbow arthroplasty - a scoping review. BMC Musculoskelet Disord 2023; 24:42. [PMID: 36653765 PMCID: PMC9847152 DOI: 10.1186/s12891-023-06149-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/07/2022] [Accepted: 01/09/2023] [Indexed: 01/19/2023] Open
Abstract
BACKGROUND Overloading is hypothesized to be one of the failure mechanisms following total elbow arthroplasty (TEA). It is unclear whether the current post-operative loading instruction is compliant with reported failure mechanisms. Aim is therefore to evaluate the elbow joint load during activities of daily living (ADL) and compare these loads with reported failure limits from retrieval and finite element studies. METHODS A scoping review of studies until 23 November 2021 investigating elbow joint load during ADL were identified by searching PubMed/Medline and Web of Science. Studies were eligible when: (1) reporting on the elbow joint load in native elbows or elbows with an elbow arthroplasty in adults; (2) full-text article was available. RESULTS Twenty-eight studies with a total of 256 participants were included. Methodological quality was low in 3, moderate in 22 and high in 3 studies. Studies were categorized as 1) close to the body and 2) further away from the body. Tasks were then subdivided into: 1) cyclic flexion/extension, 2) push-up, 3) reaching, 4) self-care, 5) work. Mean flexion-extension joint load was 17 Nm, mean varus-valgus joint load 9 Nm, mean pronation-supination joint load 8 Nm and mean bone-on-bone contact force 337 N. CONCLUSION The results of our scoping review give a first overview of the current knowledge on elbow joint loads during ADL. Surprisingly, the current literature is not sufficient to formulate a postoperative instruction for elbow joint loading, which is compliant with failure limits of the prosthesis. In addition, our current instruction does not appear to be evidence-based. Our recommendations offer a starting point to assist clinicians in providing informed decisions about post-operative instructions for their patients.
Collapse
|
6
|
Postoperative management of total elbow arthroplasty: Results of a European survey among orthopedic surgeons. PLoS One 2022; 17:e0277662. [PMID: 36374842 PMCID: PMC9662720 DOI: 10.1371/journal.pone.0277662] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2022] [Accepted: 11/01/2022] [Indexed: 11/16/2022] Open
Abstract
Background The number of complications after total elbow arthroplasty (TEA) is high and survival rates are low compared to hip and knee arthroplasties. The most common reason for revision is aseptic loosening, which might be caused by overloading of the elbow. In an attempt to lower failure rates, current clinical practice is to restrict activities for patients with a TEA. However, postoperative management of TEA is a poorly investigated topic, as no evidence-based clinical guidelines exist and the aftercare is often surgeon-based. In this study we evaluated the current postoperative management of TEA among orthopedic surgeons. Methods An online survey of 30 questions was sent to 635 members of the European Society for Surgery of the Shoulder and the Elbow (SECEC/ESSSE), about 10% (n = ± 64) of whom are considered dedicated elbow specialists. The questions were on characteristics of the surgeon and on the surgeon’s preferred postoperative management, including items to be assessed on length of immobilization, amount of weight bearing and axial loading, instructions on lifelong activities, physiotherapy, and postoperative evaluation of the elbow. Results The survey was completed by 54 dedicated elbow specialists from 17 different countries. Postoperative immobilization of the elbow was advised by half of respondents when using the triceps-sparing approach (52%), and even more with the triceps-detaching approach (65%). Postoperative passive movement of the elbow was allowed in the triceps-sparing approach (91%) and in the triceps-detaching approach (87%). Most respondents gave recommendations on weight bearing (91%) or axial loading (76%) by the affected elbow, but the specification shows significant variation. Conclusion The results from this survey demonstrate a wide variation in postoperative care of TEA. The lack of consensus in combination with low survival rates stresses the need for clinical guidelines. Further research should focus on creating these guidelines to improve follow-up care for TEA.
Collapse
|
7
|
Mid-term results of the Latitude primary total elbow arthroplasty. J Shoulder Elbow Surg 2022; 31:382-390. [PMID: 34619349 DOI: 10.1016/j.jse.2021.08.028] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/06/2021] [Revised: 08/25/2021] [Accepted: 08/29/2021] [Indexed: 02/01/2023]
Abstract
BACKGROUND The Latitude total elbow prosthesis is a third-generation implant, developed to restore the natural anatomy of the elbow. Literature on this prosthesis is scarce. The aim of this study was to analyze the mid-term results of the Latitude total elbow prosthesis. METHODS We retrospectively evaluated 62 patients (21 men and 41 women). The mean age at the time of surgery was 65 years (range, 28-87 years). The main indication for surgery was inflammatory arthritis. The outcome measures were complications, reoperations, self-reported physical functioning, pain, satisfaction, objectively measured physical functioning, and radiologic signs of loosening. Kaplan-Meier survival analysis was used to determine survival with revision as the endpoint. RESULTS Sixty-nine primary Latitude prostheses were placed in 62 patients between 2008 and 2019. Six patients (7 prostheses) died, 3 elbows underwent revision, and 9 patients were lost to follow-up. A total of 44 patients (50 prostheses) were available for follow-up. The mean length of follow-up was 51 months (range, 10-144 months). Kaplan-Meier survival analysis showed a survival rate of 82% at 10 years after surgery. The main reason for revision was aseptic loosening. Radial head dissociation was seen in 8 patients (24%), but none had complaints. Self-reported and objectively measured physical functioning yielded good results, although 23 patients (46%) did show radiolucent lines on radiographs. CONCLUSION Latitude total elbow arthroplasty is considered a successful procedure with low pain scores, high patient satisfaction, and good physical functioning. Survival rates nonetheless remain low and complication rates remain high yet are comparable to those of other elbow arthroplasties. We recommend biomechanical studies to concentrate on specific postoperative loading instructions to minimize wear and consequent loosening.
Collapse
|
8
|
Triceps Insufficiency After Total Elbow Arthroplasty: A Systematic Review. JBJS Rev 2021; 9:01874474-202107000-00008. [PMID: 34270508 DOI: 10.2106/jbjs.rvw.20.00281] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
BACKGROUND The incidence of triceps insufficiency after total elbow arthroplasty (TEA) varies in the literature, and a consensus on treatment strategy is lacking. We review the incidence, the risk factors, the clinical presentation, and the diagnosis and treatment of triceps insufficiency after TEA. Based on this information, we have formulated recommendations for clinical practice. METHODS We performed a systematic review of the literature from January 2003 to April 2020 to identify studies that investigated triceps function following TEA by searching the PubMed, Cochrane, and Embase databases. Eligible studies (1) reported on triceps function following primary or revision TEA for every indication, regardless of technique (e.g., bone grafts), (2) included ≥6 adult patients, (3) had the full-text article available, and (4) had a minimum follow-up of 1 year. RESULTS Eighty studies with a total of 4,825 TEAs were included. The quality was low in 15 studies, moderate in 64 studies, and high in 1 study. The mean incidence of triceps insufficiency was 4.5%. The rates were highest in patients after revision TEA (22%), in those with posttraumatic arthritis as an indication for surgery (10.2%), and after a triceps-reflecting approach (4.9%). Most studies used the Medical Research Council scale to score triceps function, although cutoff points and the definition of triceps insufficiency differed among studies. Surgical treatment showed favorable results with anconeus tendon transfer and Achilles allograft repair when compared with direct repair. CONCLUSIONS The incidence of triceps insufficiency varies greatly, probably due to a lack of consensus on the definition of the term. Therefore, we recommend the guidelines for clinical practice that are presented in this article. These guidelines assist clinicians in providing the best possible treatment strategy for their patients and help researchers optimize their future study designs in order to compare outcomes. LEVEL OF EVIDENCE Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Collapse
|
9
|
Prospective cohort study comparing a triceps-sparing and triceps-detaching approach in total elbow arthroplasty: a protocol. BMJ Open 2021; 11:e046098. [PMID: 33952551 PMCID: PMC8103376 DOI: 10.1136/bmjopen-2020-046098] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND New surgical approaches have been developed to optimise elbow function after total elbow arthroplasty (TEA). Currently, there is no consensus on the best surgical approach. This study aims to investigate the functional outcomes, prosthetic component position and complication rates after a triceps-sparing and a triceps-detaching approach in TEA. METHODS AND ANALYSIS A multicentre prospective comparative cohort study will be conducted. All patients with an indication for primary TEA will enrol in either the triceps-sparing or the triceps-detaching cohort. Primary outcome measure is elbow function, specified as fixed flexion deformity. Secondary outcome parameters are self-reported and objectively measured physical functioning, including triceps force, prosthetic component position in standard radiographs and complications. DISCUSSION The successful completion of this study will clarify which surgical approach yields better functional outcomes, better prosthetic component position and lower complication rates in patients with a TEA. ETHICS AND DISSEMINATION The Medical Ethics Review Board of University Medical Center Groningen reviewed the study and concluded that it is not clinical research with human subjects as meant in the Medical Research Involving Human Subjects Act (WMO), therefore WMO approval is not needed (METc2019/544). TRIAL REGISTRATION NUMBER NTR NL8488.
Collapse
|
10
|
Should all hip and knee prosthetic joints be aspirated prior to revision surgery? Arch Orthop Trauma Surg 2021; 141:461-468. [PMID: 33559723 PMCID: PMC7900020 DOI: 10.1007/s00402-021-03791-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/18/2020] [Accepted: 01/11/2021] [Indexed: 10/27/2022]
Abstract
AIMS It is essential to exclude a periprosthetic joint infection (PJI) prior to revision surgery. It is recommended to routinely aspirate the joint before surgery. However, this may not be necessary in a subgroup of patients. The aim of our study was to investigate if specific clinical and implant characteristics could be identified to rule out a PJI prior to revision surgery. METHODS We retrospectively evaluated clinical and implant characteristics of patients who underwent a hip or knee revision surgery between October 2015 and October 2018. Patients were diagnosed with a PJI according to the MSIS diagnostic criteria. RESULTS A total of 156 patients were analyzed, including 107 implants that were revised because of prosthetic loosening and 49 because of mechanical failure (i.e. instability, malalignment or malpositioning). No PJI was diagnosed in the group with mechanical failure. In the prosthetic loosening group, 20 of 107 were diagnosed with a PJI (19%). Although there was a significantly lower chance of having a PJI with an implant age of > 5 years combined with a CRP < 5 mg/L, an infection was still present in 3 out of 39 cases (8%). CONCLUSION Implants with solely mechanical failure without signs of loosening and low inflammatory parameters probably do not require a synovial fluid aspiration. These results need to be confirmed in a larger cohort of patients. In case of prosthetic loosening, all joints need to be aspirated before surgery as no specific characteristic could be identified to rule out an infection.
Collapse
|
11
|
Long-term results of the iBP elbow prosthesis: beware of destructive metallosis! BMC Musculoskelet Disord 2019; 20:415. [PMID: 31488129 PMCID: PMC6729027 DOI: 10.1186/s12891-019-2781-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/14/2019] [Accepted: 08/26/2019] [Indexed: 11/23/2022] Open
Abstract
Background The aim of this study was to review the long-term results of the instrumented Bone Preserving (iBP) elbow prosthesis. Methods Thirty-one patients (10 M, 21F, 28-77 year) were retrospectively evaluated using the Oxford Elbow Score (OES), Disabilities of Arm, Shoulder and Hand Outcome Measure (DASH), Mayo Elbow Performance (MEPS), physical examination and standard radiographs. Kaplan-Meier survival analysis was used. Results Thirty-seven primary iBPs have been placed in 31 patients between 2000 and 2007. Six patients (8 prostheses) had died, 10 elbows had been revised and three patients (4 prostheses) were lost to follow-up. Fourteen patients (15 prostheses) were available for follow-up. The main indication for surgery was rheumatoid arthritis. Mean follow-up was 11 years (8–15). Kaplan-Meier survival analysis showed a survival of 81% at 10 years after surgery. Main reason for revision was particle disease and loosening due to instability and malalignment. Eleven of 14 patients were satisfied, although radiographs showed radiolucencies in 11 patients. Conclusion The iBP elbow prosthesis gives a survival rate of 81% 10 years after surgery with a progressive decline beyond 10 years. However, many patients have radiolucencies. Discrepancy between clinical signs and radiological results warrants structural follow-up, to assure quality of bone stock in case revision surgery is indicated. The study was reviewed and approved by the Medical Ethical Committee of University Medical Center Groningen (METc2016/038). Level of evidence Level IV, Case series.
Collapse
|
12
|
Tibial component with and without stem extension in a trabecular metal cone construct. Knee Surg Sports Traumatol Arthrosc 2017; 25:3644-3652. [PMID: 27592329 PMCID: PMC5644686 DOI: 10.1007/s00167-016-4271-2] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/21/2016] [Accepted: 08/05/2016] [Indexed: 11/25/2022]
Abstract
PURPOSE The purpose of this study was to investigate stability and strain distribution of a tibial plateau reconstruction with a trabecular metal cone while the tibial component is implanted with and without a stem, and whether prosthetic stability was influenced by bone mineral density. Trabecular metal cones are designed to fill up major bone defects in total knee arthroplasty. Tibial components can be implanted in combination with a stem, but it is unclear whether this is necessary after reconstruction with a trabecular metal cone. Implanting a stem can give extra stability, but may have negative side effects. METHODS Tibial revision arthroplasties with trabecular metal cones were performed after reconstruction of a 2B bone defect according to the Anderson Orthopedic Research Institute classification. Components were implanted in seven pairs of cadaveric tibiae; one tibia of each pair was implanted with stem and the other without. All specimens were loaded to one bodyweight alternating between the medial and lateral tibial component. Implant-bone micro-motions, bone strains, bone mineral density and correlations were measured and/or calculated. RESULTS Tibial components without a stem showed only more varus tilt [difference in median 0.14° (P < 0.05)], but this was not considered clinically relevant. Strain distribution did not differ. Bone mineral density only had an effect on the anterior/posterior tilt [ρ: -0.72 (P < 0.01)]. CONCLUSION Tibial components, with or without a stem, which are implanted after reconstruction of major bone defects using trabecular metal cones produce very similar biomechanical conditions in terms of stability and strain distribution. If in vivo studies confirm that a stem extension is not mandatory, orthopaedic surgeons can decide not to implant a stem. LEVEL OF EVIDENCE II.
Collapse
|
13
|
Do CAS measurements correlate with EOS 3D alignment measurements in primary TKA? Knee Surg Sports Traumatol Arthrosc 2017; 25:2894-2903. [PMID: 26913857 PMCID: PMC5570772 DOI: 10.1007/s00167-016-4031-3] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/26/2015] [Accepted: 01/26/2016] [Indexed: 11/28/2022]
Abstract
PURPOSE Objective of this study was to compare intraoperative computer-assisted surgery (CAS) alignment measurements during total knee arthroplasty (TKA) with pre- and postoperative coronal alignment measurements using EOS 3D reconstructions. METHODS In a prospective study, 56 TKAs using imageless CAS were performed and coronal alignment measurements were recorded twice: before bone cuts were made and after implantation of the prosthesis. Pre- and postoperative coronal alignment measurements were performed using EOS 3D reconstructions. Thanks to the EOS radiostereography system, measurement errors due to malpositioning and deformity during acquisition are eliminated. CAS measurements were compared with EOS 3D reconstructions. Varus/valgus angle (VV), mechanical lateral distal femoral angle (mLDFA) and mechanical medial proximal tibial angle (mMPTA) were measured. RESULTS Significantly different VV angles were measured pre- and postoperatively with CAS compared to EOS. For preoperative measurements, mLDFA did not differ significantly, but a significantly larger mMPTA in valgus was measured with CAS. CONCLUSION Results of this study indicate that differences in alignment measurements between CAS measurements and pre- and postoperative EOS 3D are due mainly to the difference between weight-bearing and non-weight-bearing position and potential errors in validity and reliability of the CAS system. EOS 3D measurements overestimate VV angle in lower limbs with substantial mechanical axis deviation. For lower limbs with minor mechanical axis deviation as well as for mMPTA measurements, CAS measures more valgus than EOS. Eventually the results of this study are of clinical relevance, since it raises concerns regarding the validity and reliability of CAS systems in TKA. LEVEL OF EVIDENCE IIb.
Collapse
|
14
|
The Validity of a New Low-Dose Stereoradiography System to Perform 2D and 3D Knee Prosthetic Alignment Measurements. PLoS One 2016; 11:e0146187. [PMID: 26771177 PMCID: PMC4714906 DOI: 10.1371/journal.pone.0146187] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2015] [Accepted: 12/14/2015] [Indexed: 11/20/2022] Open
Abstract
Introduction The EOS stereoradiography system has shown to provide reliable varus/valgus (VV) measurements of the lower limb in 2D (VV2D) and 3D (VV3D) after total knee arthroplasty (TKA). Validity of these measurements has not been investigated yet, therefore the purpose of this study was to determine validity of EOS VV2D and VV3D. Methods EOS images were made of a lower limb phantom containing a knee prosthesis, while varying VV angle from 15° varus to 15° valgus and flexion angle from 0° to 20°, and changing rotation from 20° internal to 20° external rotation. Differences between the actual VV position of the lower limb phantom and its position as measured on EOS 2D and 3D images were investigated. Results Rotation, flexion or VV angle alone had no major impact on VV2D or VV3D. Combination of VV angle and rotation with full extension did not show major differences in VV2D measurements either. Combination of flexion and rotation with a neutral VV angle showed variation of up to 7.4° for VV2D; maximum variation for VV3D was only 1.5°. A combination of the three variables showed an even greater distortion of VV2D, while VV3D stayed relatively constant. Maximum measurement difference between preset VV angle and VV2D was 9.8°, while the difference with VV3D was only 1.9°. The largest differences between the preset VV angle and VV2D were found when installing the leg in extreme angles, for example 15° valgus, 20° flexion and 20° internal rotation. Conclusions After TKA, EOS VV3D were more valid than VV2D, indicating that 3D measurements compensate for malpositioning during acquisition. Caution is warranted when measuring VV angle on a conventional radiograph of a knee with a flexion contracture, varus or valgus angle and/or rotation of the knee joint during acquisition.
Collapse
|
15
|
Does imageless computer-assisted TKA lead to improved rotational alignment or fewer outliers? A systematic review. Clin Orthop Relat Res 2014; 472:3124-33. [PMID: 24867451 PMCID: PMC4160487 DOI: 10.1007/s11999-014-3688-5] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/17/2013] [Accepted: 05/08/2014] [Indexed: 01/31/2023]
Abstract
BACKGROUND Computer-assisted surgery (CAS) has been developed to enhance prosthetic alignment during primary TKAs. Imageless CAS improves coronal and sagittal alignment compared with conventional TKA. However, the effect of imageless CAS on rotational alignment remains unclear. QUESTIONS/PURPOSES We conducted a systematic and qualitative review of the current literature regarding the effectiveness of imageless CAS during TKA on (1) rotational alignment of the femoral and tibial components and tibiofemoral mismatch in terms of deviation from neutral rotation, and (2) the number of femoral and tibial rotational outliers. METHODS Data sources included PubMed, MEDLINE, and EMBASE. Study selection, data extraction, and methodologic quality assessment were conducted independently by two reviewers. Standardized mean difference with 95% CI was calculated for continuous variables (rotational alignment of the femoral or tibial component and tibiofemoral mismatch). To compare the number of outliers for femoral and tibial component rotation, the odds ratio and 95% CI were calculated. The literature search produced 657 potentially relevant studies, 17 of which met the inclusion criteria. One study was considered as having high methodologic quality, 15 studies had medium, and one study had low quality. RESULTS Conflicting evidence was found for all outcome measures except for tibiofemoral mismatch. Moderate evidence was found that imageless CAS had no influence on postoperative tibiofemoral mismatch. The measurement protocol for measuring tibial rotation varied among the studies and in only one of the studies was the sample size calculation based on one of the outcome measures used in our systematic review. CONCLUSIONS More studies of high methodologic quality and with a sample size calculation based on the outcome measures will be helpful to assess whether an imageless CAS TKA improves femoral and tibial rotational alignment and tibiofemoral mismatch or decreases the number of femoral and tibial rotational outliers. To statistically analyze the results of different studies, the same measurement protocol should be used among the studies.
Collapse
|
16
|
Assessment of prosthesis alignment after revision total knee arthroplasty using EOS 2D and 3D imaging: a reliability study. PLoS One 2014; 9:e104613. [PMID: 25247714 PMCID: PMC4172435 DOI: 10.1371/journal.pone.0104613] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2014] [Accepted: 07/15/2014] [Indexed: 11/18/2022] Open
Abstract
Introduction A new low-dose X-ray device, called EOS, has been introduced for determining lower-limb alignment in 2D and 3D. Reliability has not yet been assessed when using EOS on lower limbs containing a knee prosthesis. Therefore purpose of this study was to determine intraobserver and interobserver reliability of EOS 2D and 3D knee prosthesis alignment measurements after revision total knee arthroplasty (rTKA). Methods Forty anteroposterior and lateral images of 37 rTKA patients were included. Two observers independently performed measurements on these images twice. Varus/valgus angles were measured in 2D (VV2D) and 3D (VV3D). Intraclass correlation coefficients and the Bland and Altman method were used to determine reliability. T-tests were used to test potential differences. Results Intraobserver and interobserver reliability were excellent for VV2D and VV3D. No significant difference or bias between the first and second measurements or the two observers was found. A significant mean and absolute difference of respectively 1.00° and 1.61° existed between 2D and 3D measurements. Conclusions EOS provides reliable varus/valgus measurements in 2D and 3D for the alignment of the knee joint with a knee prosthesis. However, significant differences exist between varus/valgus measurements in 2D and 3D.
Collapse
|
17
|
The influence of computer-assisted surgery on rotational, coronal and sagittal alignment in revision total knee arthroplasty. BMC Musculoskelet Disord 2014; 15:94. [PMID: 24646028 PMCID: PMC3995112 DOI: 10.1186/1471-2474-15-94] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/19/2013] [Accepted: 03/10/2014] [Indexed: 11/15/2022] Open
Abstract
Background Despite good results of primary total knee arthroplasty (TKA), the number of revision total knee arthroplasties (rTKAs) is rising. Proper implant position is essential, since malposition leads to worse clinical outcome. In rTKA most anatomical landmarks have disappeared because of extensive bone loss, making it more difficult to adequately implant the knee prosthesis. In primary TKA, computer-assisted surgery (CAS) leads to better prosthetic alignment than mechanical navigation guides. Literature about the use of CAS in rTKA is scarce though, and the effect on rotational prosthetic alignment has not been investigated yet. Hence the primary objective of this study is to compare rotational prosthetic alignment when using CAS in rTKA compared to a mechanical navigation guide. Secondary objectives are to compare prosthetic alignment in the coronal and sagittal planes. It is hypothesized that CAS leads to better rotational, coronal and sagittal prosthetic alignment when used during rTKA. Methods/Design A prospective clinical intervention study with use of a historical control group will be conducted. Forty-four patients with a minimum age of 18 to be admitted for CAS-rTKA between September 2012 and September 2015 will be included in the intervention group. Forty-four patients with a minimum age of 18 who underwent rTKA with the use of a mechanical navigation guide between January 2002 and April 2012 will form the historical control group. Both groups will be matched according to gender and type of revision prosthesis. Rotational prosthesis alignment will be evaluated using a CT-scan of the knee joint. Discussion Proper implant position is essential, since malposition leads to worse clinical outcome. Several studies show a significantly positive influence of CAS on prosthetic alignment in primary TKA, but literature about the use of CAS in rTKA is limited. The purpose of this study is thus to investigate the influence of CAS during rTKA on postoperative prosthetic alignment, compared to mechanical navigation guides. Trial registration Netherlands National Trial Register NTR3512
Collapse
|
18
|
|
19
|
Comparison of gait in patients following a computer-navigated minimally invasive anterior approach and a conventional posterolateral approach for total hip arthroplasty: a randomized controlled trial. J Orthop Res 2013; 31:288-94. [PMID: 22886805 DOI: 10.1002/jor.22210] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/20/2011] [Accepted: 07/19/2012] [Indexed: 02/04/2023]
Abstract
Minimally invasive total hip arthroplasty (MIS THA) aims at minimizing damage to muscles and tendons to accelerate postoperative recovery. Computer navigation allows a precise prosthesis alignment without complete visualization of the bony landmarks during MIS THA. A randomized controlled trial (RCT) was conducted to determine the effectiveness of a computer-navigated MIS anterior approach for THA compared to a conventional posterolateral THA technique on the restoration of physical functioning during recovery following surgery. Thirty-five patients underwent computer-navigated MIS THA via the anterior approach, and 40 patients underwent conventional THA using the conventional posterolateral approach. Gait analysis was performed preoperatively, 6 weeks, and 3 and 6 months postoperatively using a body-fixed-sensor based gait analysis system. Walking speed, step length, cadence, and frontal plane angular movements of the pelvis and thorax were assessed. The same data were obtained from 30 healthy subjects. No differences were found in the recovery of spatiotemporal parameters or in angular movements of the pelvis and thorax following the computer-navigated MIS anterior approach or the conventional posterolateral approach. Although gait improved after surgery, small differences in several spatiotemporal parameters and angular movements of the trunk remained at 6 months postoperatively between both patient groups and healthy subjects.
Collapse
|
20
|
|
21
|
Minimally invasive and computer-navigated total hip arthroplasty: a qualitative and systematic review of the literature. BMC Musculoskelet Disord 2010; 11:92. [PMID: 20470443 PMCID: PMC2879237 DOI: 10.1186/1471-2474-11-92] [Citation(s) in RCA: 59] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/18/2009] [Accepted: 05/17/2010] [Indexed: 11/29/2022] Open
Abstract
Background Both minimally invasive surgery (MIS) and computer-assisted surgery (CAS) for total hip arthroplasty (THA) have gained popularity in recent years. We conducted a qualitative and systematic review to assess the effectiveness of MIS, CAS and computer-assisted MIS for THA. Methods An extensive computerised literature search of PubMed, Medline, Embase and OVIDSP was conducted. Both randomised clinical trials and controlled clinical trials on the effectiveness of MIS, CAS and computer-assisted MIS for THA were included. Methodological quality was independently assessed by two reviewers. Effect estimates were calculated and a best-evidence synthesis was performed. Results Four high-quality and 14 medium-quality studies with MIS THA as study contrast, and three high-quality and four medium-quality studies with CAS THA as study contrast were included. No studies with computer-assisted MIS for THA as study contrast were identified. Strong evidence was found for a decrease in operative time and intraoperative blood loss for MIS THA, with no difference in complication rates and risk for acetabular outliers. Strong evidence exists that there is no difference in physical functioning, measured either by questionnaires or by gait analysis. Moderate evidence was found for a shorter length of hospital stay after MIS THA. Conflicting evidence was found for a positive effect of MIS THA on pain in the early postoperative period, but that effect diminished after three months postoperatively. Strong evidence was found for an increase in operative time for CAS THA, and limited evidence was found for a decrease in intraoperative blood loss. Furthermore, strong evidence was found for no difference in complication rates, as well as for a significantly lower risk for acetabular outliers. Conclusions The results indicate that MIS THA is a safe surgical procedure, without increases in operative time, blood loss, operative complication rates and component malposition rates. However, the beneficial effect of MIS THA on functional recovery has to be proven. The results also indicate that CAS THA, though resulting in an increase in operative time, may have a positive effect on operative blood loss and operative complication rates. More importantly, the use of CAS results in better positioning of acetabular component of the prosthesis.
Collapse
|
22
|
Hypoxia inducible factor-1-alpha (HIF-1alpha) is related to both angiogenesis and inflammation in rheumatoid arthritis. Clin Exp Rheumatol 2009; 27:945-951. [PMID: 20149310] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
OBJECTIVES Despite the important role of the transcription factor HIF-1alpha in angiogenesis and inflammation, only a few studies on HIF-1alpha expression have been performed in RA patients. The aim of the present study was to identify the layer in synovial tissue of RA patients where HIF1a is expressed and to find out whether HIF-1alpha expression is related to both angiogenesis and inflammation in synovium from RA patients. METHODS A reproducible staining method for HIF-1alpha was developed. HIF-1alpha -positive cells were quantified in synovial tissue from patients with RA. As control we used synovial tissue from patients with osteoarthritis (OA). The number of HIF-1alpha-positive cells was compared with the number of blood vessels present and was correlated with the amount of inflammation. The amount of inflammation was determined by counting inflammatory cells, by estimating the proliferation marker Ki67 in inflamed tissue, and by using a recently published synovitis score which gives an accurate estimate of the amount of inflammation present. RESULTS HIF-1alpha was expressed weakly in the lining layer and strongly in the sublining layer in RA synovial tissue. In contrast, HIF-1alpha was only weakly expressed in OA synovial tissue. The number of HIF-1alpha -positive cells correlated strongly with the number of blood vessels in RA synovial tissue and with inflammatory endothelial cell infiltration (blood vessels), cell proliferation (Ki67) and the synovitis score. CONCLUSIONS HIF-1alpha expression is strongest in the sub-lining layer of RA synovium and is related to both angiogenesis and inflammation in synovium from RA patients. These results thus suggest that HIF-1alpha could serve as an important new therapeutic target in RA, targeting both angiogenesis and inflammation.
Collapse
|
23
|
Abstract
Bilateral coracoclavicular joints were found in a 44-year-old male patient following a fall. He had an Indonesian mother and a Dutch father. Prior to the injury he was asymptomatic and had full range of movement in both shoulders but the trauma resulted in pain and limitation of movement in the left shoulder which required resection of the anomalous joint, after which full pain-free movement was restored.
Collapse
|
24
|
Atypical hamstrings electromyographic activity as a compensatory mechanism in anterior cruciate ligament deficiency. Knee Surg Sports Traumatol Arthrosc 2001; 9:211-6. [PMID: 11522076 DOI: 10.1007/s001670100196] [Citation(s) in RCA: 70] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Anterior cruciate ligament (ACL) deficiency may cause functional instability of the knee (noncopers), while other patients compensate and perform at the same level as before injury (copers). This pilot study investigated whether there is a compensatory electromyographic (EMG) activity of the hamstrings in copers, noncopers and control patients. Ten patients with an ACL deficiency were equally divided into two groups of copers and noncopers. All patients underwent gait analysis with EMG of six muscles around the knee. Ten healthy young men formed the control group. In contrast to noncopers, copers showed an atypical semitendinosus activity during stance phase; the corresponding trend was found in biceps femoris activity. There was no difference between copers and controls in knee extension during stance phase. The noncopers had less knee extension. Atypical hamstring muscle activity may thus be a compensatory mechanism by which copers enable themselves to perform on a normal level.
Collapse
|
25
|
Abstract
Twelve of 14 patients who underwent arthrolysis of the elbow for post-traumatic stiffness were re-examined after a mean of 62 months. Pain and subjective stiffness were improved. The mean function of the elbow improved from 73 degrees to 112 degrees. Those operated on within a year of their injury improved twice as much as those who had been operated on after a longer period. Arthrolysis may be very rewarding when conservative treatment fails, especially when it is carried out within a year of the injury.
Collapse
|