1
|
Validation of mixed-reality surgical navigation for glenoid axis pin placement in shoulder arthroplasty using a cadaveric model. J Shoulder Elbow Surg 2024; 33:1177-1184. [PMID: 37890765 DOI: 10.1016/j.jse.2023.09.027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/16/2023] [Revised: 09/16/2023] [Accepted: 09/24/2023] [Indexed: 10/29/2023]
Abstract
BACKGROUND Mixed reality may offer an alternative for computer-assisted navigation in shoulder arthroplasty. The purpose of this study was to determine the accuracy and precision of mixed-reality guidance for the placement of the glenoid axis pin in cadaver specimens. This step is essential for accurate glenoid placement in total shoulder arthroplasty. METHODS Fourteen cadaveric shoulders underwent simulated shoulder replacement surgery by 7 experienced shoulder surgeons. The surgeons exposed the cadavers through a deltopectoral approach and then used mixed-reality surgical navigation to insert a guide pin in a preplanned position and trajectory in the glenoid. The mixed-reality system used the Microsoft Hololens 2 headset, navigation software, dedicated instruments with fiducial marker cubes, and a securing pin. Computed tomography scans obtained before and after the procedure were used to plan the surgeries and determine the difference between the planned and executed values for the entry point, version, and inclination. One specimen had to be discarded from the analysis because the guide pin was removed accidentally before obtaining the postprocedure computed tomography scan. RESULTS Regarding the navigated entry point on the glenoid, the mean difference between planned and executed values was 1.7 ± 0.8 mm; this difference was 1.2 ± 0.6 mm in the superior-inferior direction and 0.9 ± 0.8 mm in the anterior-posterior direction. The maximum deviation from the entry point for all 13 specimens analyzed was 3.1 mm. Regarding version, the mean difference between planned and executed version values was 1.6° ± 1.2°, with a maximum deviation in version for all 13 specimens of 4.1°. Regarding inclination, the mean angular difference was 1.7° ± 1.5°, with a maximum deviation in inclination of 5°. CONCLUSIONS The mixed-reality navigation system used in this study allowed surgeons to insert the glenoid guide pin on average within 2 mm from the planned entry point and within 2° of version and inclination. The navigated values did not exceed 3 mm or 5°, respectively, for any of the specimens analyzed. This approach may help surgeons more accurately place the definitive glenoid component.
Collapse
|
2
|
Three-Dimensional Measurement of Proximal Humerus Fractures Displacement: A Computerized Analysis. J Clin Med 2023; 12:4085. [PMID: 37373779 DOI: 10.3390/jcm12124085] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2023] [Revised: 06/01/2023] [Accepted: 06/14/2023] [Indexed: 06/29/2023] Open
Abstract
Neer's classification for proximal humerus fractures (PHFs) uses 10 mm and 45° thresholds to distinguish displaced fragments. While this system was originally developed referencing 2D X-rays, fracture displacements occur in three dimensions. Our work aimed to develop a standardized and reliable computerized method for measuring PHF 3D spatial displacements. CT scans of 77 PHFs were analyzed. A statistical shape model (SSM) was used to generate the pre-fracture humerus. This predicted proximal humerus was then used as a "layer" to manually reduce fragments to their native positions and quantify translation and rotation in three dimensions. 3D computerized measurements could be calculated for 96% of fractures and revealed that 47% of PHFs were displaced according to Neer's criteria. Valgus and varus head rotations in the coronal plane were present in 39% and 45% of cases; these were greater than 45° in 8% of cases and were always associated with axial and sagittal rotations. When compared to 3D measurements, 2D methods underestimated the displacement of tuberosity fragments and did not accurately assess rotational displacements. The use of 3D measurements of fracture displacement is feasible with a computerized method and may help further refine PHF analysis and surgical planning.
Collapse
|
3
|
Can surgeons optimize range of motion and reduce scapulohumeral impingements in reverse shoulder arthroplasty? A computational study. Shoulder Elbow 2022; 14:385-394. [PMID: 35846405 PMCID: PMC9284303 DOI: 10.1177/1758573221994141] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/23/2020] [Revised: 12/12/2020] [Accepted: 01/20/2021] [Indexed: 11/17/2022]
Abstract
BACKGROUND Early glenohumeral impingement leads to poor range of motion and notching in reverse shoulder arthroplasty. The aim was to find from planning software which implant configuration provides the best motions in reverse shoulder arthroplasty. PATIENTS AND METHODS Reverse shoulder arthroplasty planning (Glenosys) was made in 31 patients (12 men, 19 women, 76 ± 6 yo) and impingements were analyzed. Inlay (155°-inclined) and Onlay (145°-inclined) humeral designs were tested. Four configurations were tested for each shoulder: "INLAY": non-lateralized glenoid-inlay humerus, "BIO-INLAY": lateralized glenoid (BIO-RSA)-inlay humerus, "ONLAY": non-lateralized glenoid-onlay humerus, and "BIO-ONLAY": lateralized (BIO-RSA) glenoid-onlay humerus. RESULTS BIO-ONLAY and BIO-INLAY groups presented a significantly better result in all tested motion (p < 0.001 for all tests). BIO-ONLAY allowed a significantly better external rotation, extension and adduction than BIO-INLAY with decreased impingements with the pilar. BIO-INLAY presented a significantly better abduction. In abduction, an abutment of the greater tuberosity against the acromion was associated with a lower range of motion (p < 0.0001) and did not depend on the lateralization. CONCLUSION Glenoid lateralization delays the glenohumeral impingement in reverse shoulder arthroplasty and gives the best rotations, adduction and extension when associated with neutral inclination and humeral 145° inclination. Greater tuberosity abutment has to be avoided in abduction and the Inlay design provides the best abduction.
Collapse
|
4
|
Patient Posture Affects Simulated ROM in Reverse Total Shoulder Arthroplasty: A Modeling Study Using Preoperative Planning Software. Clin Orthop Relat Res 2022; 480:619-631. [PMID: 34669618 PMCID: PMC8846281 DOI: 10.1097/corr.0000000000002003] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/21/2021] [Accepted: 09/16/2021] [Indexed: 01/31/2023]
Abstract
BACKGROUND Component selection and placement in reverse total shoulder arthroplasty (RTSA) is still being debated. Recently, scapulothoracic orientation and posture have emerged as relevant factors when planning an RTSA. However, the degree to which those parameters may influence ROM and whether modifiable elements of implant configuration may be helpful in improving ROM among patients with different postures have not been thoroughly studied, and modeling them may be instructive. QUESTIONS/PURPOSES Using a dedicated expansion of a conventional preoperative planning software, we asked: (1) How is patient posture likely to influence simulated ROM after virtual RTSA implantation? (2) Do changes in implant configuration, such as humeral component inclination and retrotorsion, or glenoid component size and centricity improve the simulated ROM after virtual RTSA implantation in patients with different posture types? METHODS In a computer laboratory study, available whole-torso CT scans of 30 patients (20 males and 10 females with a mean age of 65 ± 17 years) were analyzed to determine the posture type (Type A, upright posture, retracted scapulae; Type B, intermediate; Type C, kyphotic posture with protracted scapulae) based on the measured scapula internal rotation as previously described. The measurement of scapular internal rotation, which defines these posture types, was found to have a high intraclass correlation coefficient (0.87) in a previous study, suggesting reliability of the employed classification. Three shoulder surgeons each independently virtually implanted a short, curved, metaphyseal impaction stem RTSA in each patient using three-dimensional (3D) preoperative surgical planning software. Modifications based on the original component positioning were automatically generated, including different humeral component retrotorsion (0°, 20°, and 40° of anatomic and scapular internal rotation) and neck-shaft angle (135°, 145°, and 155°) as well as glenoid component configuration (36-mm concentric, 36-mm eccentric, and 42-mm concentric), resulting in 3720 different RTSA configurations. For each configuration, the maximum potential ROM in different planes was determined by the software, and the effect of different posture types was analyzed by comparing subgroups. RESULTS Irrespective of the RTSA implant configuration, the posture types had a strong effect on the calculated ROM in all planes of motion, except for flexion. In particular, simulated ROM in patients with Type C compared with Type A posture demonstrated inferior adduction (median 5° [interquartile range -7° to 20°] versus 15° [IQR 7° to 22°]; p < 0.01), abduction (63° [IQR 48° to 78°] versus 72° [IQR 63° to 82°]; p < 0.01), extension (4° [IQR -8° to 12°] versus 19° [IQR 8° to 27°]; p < 0.01), and external rotation (7° [IQR -5° to 22°] versus 28° [IQR 13° to 39°]; p < 0.01). Lower retrotorsion and a higher neck-shaft angle of the humeral component as well as a small concentric glenosphere resulted in worse overall ROM in patients with Type C posture, with severe restriction of motion in adduction, extension, and external rotation to below 0°. CONCLUSION Different posture types affect the ROM after simulated RTSA implantation, regardless of implant configuration. An individualized choice of component configuration based on scapulothoracic orientation seems to attenuate the negative effects of posture Type B and C. Future studies on ROM after RTSA should consider patient posture and scapulothoracic orientation. CLINICAL RELEVANCE In patients with Type C posture, higher retrotorsion, a lower neck-shaft angle, and a larger or inferior eccentric glenosphere seem to be advantageous.
Collapse
|
5
|
Three-dimensional muscle loss assessment: a novel computed tomography-based quantitative method to evaluate rotator cuff muscle fatty infiltration. J Shoulder Elbow Surg 2022; 31:165-174. [PMID: 34478865 DOI: 10.1016/j.jse.2021.07.029] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/27/2021] [Revised: 07/15/2021] [Accepted: 07/26/2021] [Indexed: 02/01/2023]
Abstract
BACKGROUND Rotator cuff fatty infiltration (FI) is one of the most important parameters to predict the outcome of certain shoulder conditions. The primary objective of this study was to define a new computed tomography (CT)-based quantitative 3-dimensional (3D) measure of muscle loss (3DML) based on the rationale of the 2-dimensional (2D) qualitative Goutallier score. The secondary objective of this study was to compare this new measurement method to traditional 2D qualitative assessment of FI according to Goutallier et al and to a 3D quantitative measurement of fatty infiltration (3DFI). MATERIALS AND METHODS 102 CT scans from healthy shoulders (46) and shoulders with cuff tear arthropathy (21), irreparable rotator cuff tears (18), and primary osteoarthritis (17) were analyzed by 3 experienced shoulder surgeons for subjective grading of fatty infiltration according to Goutallier, and their rotator cuff muscles were manually segmented. Quantitative 3D measurements of fatty infiltration (3DFI) were completed. The volume of muscle fibers without intramuscular fat was then calculated for each rotator cuff muscle and normalized to the patient's scapular volume to account for the effect of body size (NVfibers). 3D muscle mass (3DMM) was calculated by dividing the NVfibers value of a given muscle by the mean expected volume in healthy shoulders. 3D muscle loss (3DML) was defined as 1 - (3DMM). The correlation between Goutallier grading, 3DFI, and 3DML was compared using a Spearman rank correlation. RESULTS Interobserver reliability for the traditional 2D Goutallier grading was moderate for the infraspinatus (ISP, 0.42) and fair for the supraspinatus (SSP, 0.38), subscapularis (SSC, 0.27) and teres minor (TM, 0.27). 2D Goutallier grading was found to be significantly and highly correlated with 3DFI (SSP, 0.79; ISP, 0.83; SSC, 0.69; TM, 0.45) and 3DML (SSP, 0.87; ISP, 0.85; SSC, 0.69; TM, 0.46) for all 4 rotator cuff muscles (P < .0001). This correlation was significantly higher for 3DML than for the 3DFI for SSP only (P = .01). The mean values of 3DFI and 3DML were 0.9% and 5.3% for Goutallier 0, 2.9% and 25.6% for Goutallier 1, 11.4% and 49.5% for Goutallier 2, 20.7% and 59.7% for Goutallier 3, and 29.3% and 70.2% for Goutallier 4, respectively. CONCLUSION The Goutallier score has been helping surgeons by using 2D CT scan slices. However, this grading is associated with suboptimal interobserver agreement. The new measures we propose provide a more consistent assessment that correlates well with Goutallier's principles. As 3DML measurements incorporate atrophy and fatty infiltration, they could become a very reliable index for assessing shoulder muscle function. Future algorithms capable of automatically calculating the 3DML of the cuff could help in the decision process for cuff repair and the choice of anatomic or reverse shoulder arthroplasty.
Collapse
|
6
|
Development and assessment of 3-dimensional computed tomography measures of proximal humeral bone density: a comparison to established 2-dimensional measures and intraoperative findings in patients undergoing shoulder arthroplasty. JSES Int 2021; 5:1008-1013. [PMID: 34766077 PMCID: PMC8569005 DOI: 10.1016/j.jseint.2021.07.015] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Background The purpose of this study was to develop novel three-dimensional (3D) measures of bone density from computed tomography (CT) scans and to compare them with validated two-dimensional (2D) radiographic assessments of bone density. Patient demographic data were also analyzed to see if there were any predictors of bone density (age, sex, etiology). Methods The study group consisted of 290 consecutive patients undergoing primary shoulder arthroplasty surgery (total anatomic, reverse, and hemiarthroplasty). All underwent preoperative CT imaging. Three 3D CT measurements (metaphysis cancellous, metaphysis cortical, and proximal diaphysis) were developed and automated into software. The developed 3D measurements were compared with validated 2D measures (Tingart and Gianotti Index). Patient demographic data were correlated with these measurements. The difference between the size of the final sounder and of the final stem was calculated as Delta. Results There was moderately strong correlation between Tingart and Gianotti measures (0.674, P < .001), as well as between 3D metaphysis cancellous measurements and Tingart (0.645, P < .001). Decreased bone density was highly correlated with female sex. Tingart (area under the curve [AUC]: 0.87, 95% confidence interval [CI]: 0.82-0.91) and 3D metaphysis cancellous (AUC: 0.78, 95% CI: 0.72-0.84) had the highest correlation. These were significantly more than other measures of bone density (P < .01). Decreased bone density measured with Tingart also had moderate correlation with advanced age (AUC: 0.67, 95% CI: 0.6-0.73), but less so for etiology (AUC: 0.62, 95% CI: 0.55-0.69). The 3D metaphysis cancellous measure had lower correlation with age (AUC: 0.59, 95% CI: 0.52-0.66) and etiology (AUC: 0.59, 95% CI: 0.52-0.65). The highest correlation with Delta (the difference between the final sounder and the stem size) was with the 3D metaphysis cancellous measure (AUC: 0.67, 95% CI: 0.59-0.73), followed by Tingart (AUC: 0.647, 95% CI: 0.57-0.671). A multiple regression model to predict Delta demonstrated the stronger prediction using 3D metaphysis cancellous (analysis of variance F-ratio of 42.6, P < .001) than Tingart (35.9, P < .001). Conclusion This study demonstrates that automated measures of bone density can be obtained from 3D CT scans. Of the three novel 3D measurements of bone density, the humeral metaphysis cancellous measurement was most correlated to the known 2D measures and most correlated to the intraoperative assessment of bone density (delta).
Collapse
|
7
|
Identification of threshold pathoanatomic metrics in primary glenohumeral osteoarthritis. J Shoulder Elbow Surg 2021; 30:2270-2282. [PMID: 33813011 DOI: 10.1016/j.jse.2021.03.140] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/30/2020] [Revised: 03/10/2021] [Accepted: 03/22/2021] [Indexed: 02/01/2023]
Abstract
BACKGROUND An assessment of the pathoanatomic parameters of the arthritic glenohumeral joint (GHJ) has the potential to identify discriminating metrics to differentiate glenoid types in shoulders with primary glenohumeral osteoarthritis (PGHOA). The aim was to identify the morphometric differences and threshold values between glenoid types including normal and arthritic glenoids with the various types in the Walch classification. We hypothesized that there would be clear morphometric discriminators between the various glenoid types and that specific numeric threshold values would allow identification of each glenoid type. METHODS The computed tomography scans of 707 shoulders were analyzed: 585 obtained from shoulders with PGHOA and 122 from shoulders without glenohumeral pathology. Glenoid morphology was classified according to the Walch classification. All computed tomography scans were imported in a dedicated automatic 3D-software program that referenced measurements to the scapular body plane. Glenoid and humeral modeling was performed using the best-fit sphere method, and the root-mean-square error was calculated. The direction and orientation of the glenoid and humerus described glenohumeral relationships. RESULTS Among shoulders with PGHOA, 90% of the glenoids and 85% of the humeral heads were directed posteriorly in reference to the scapular body plane. Several discriminatory pathoanatomic parameters were identified: GHJ narrowing < 3 mm was a discriminatory metric for type A glenoids. Posterior humeral subluxation > 70% discriminated type B1 from normal GHJs. The root-mean-square error was a discriminatory metric to distinguish type B2 from type A, type B3, and normal GHJs. Type B3 glenoids differed from type A2 by greater retroversion (>13°) and subluxation (>71%). The type C glenoid retroversion inferior limit was 21°, whereas normal glenoids never presented with retroversion > 16°. CONCLUSION Pathoanatomic metrics with the identified threshold values can be used to discriminate glenoid types in shoulders with PGHOA.
Collapse
|
8
|
Abstract
Aims The aim of this study was to describe a quantitative 3D CT method to measure rotator cuff muscle volume, atrophy, and balance in healthy controls and in three pathological shoulder cohorts. Methods In all, 102 CT scans were included in the analysis: 46 healthy, 21 cuff tear arthropathy (CTA), 18 irreparable rotator cuff tear (IRCT), and 17 primary osteoarthritis (OA). The four rotator cuff muscles were manually segmented and their volume, including intramuscular fat, was calculated. The normalized volume (NV) of each muscle was calculated by dividing muscle volume to the patient’s scapular bone volume. Muscle volume and percentage of muscle atrophy were compared between muscles and between cohorts. Results Rotator cuff muscle volume was significantly decreased in patients with OA, CTA, and IRCT compared to healthy patients (p < 0.0001). Atrophy was comparable for all muscles between CTA, IRCT, and OA patients, except for the supraspinatus, which was significantly more atrophied in CTA and IRCT (p = 0.002). In healthy shoulders, the anterior cuff represented 45% of the entire cuff, while the posterior cuff represented 40%. A similar partition between anterior and posterior cuff was also found in both CTA and IRCT patients. However, in OA patients, the relative volume of the anterior (42%) and posterior cuff (45%) were similar. Conclusion This study shows that rotator cuff muscle volume is significantly decreased in patients with OA, CTA, or IRCT compared to healthy patients, but that only minimal differences can be observed between the different pathological groups. This suggests that the influence of rotator cuff muscle volume and atrophy (including intramuscular fat) as an independent factor of outcome may be overestimated. Cite this article: Bone Jt Open 2021;2(7):552–561.
Collapse
|
9
|
Humeral head subluxation in Walch type B shoulders varies across imaging modalities. JSES Int 2021; 5:98-101. [PMID: 33554173 PMCID: PMC7846694 DOI: 10.1016/j.jseint.2020.08.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
Background The Walch type B pattern of glenohumeral osteoarthritis is characterized by posterior humeral head subluxation (PHHS). At present, it is unknown whether the percentage of subluxation measured on axillary radiographs is consistent with measurements on 2-dimensional (2D) axial or 3-dimensional (3D) volumetric computed tomography (CT). The purpose of this study was to evaluate PHHS across imaging modalities (radiographs, 2D CT, and 3D CT). Methods A cohort of 30 patients with Walch type B shoulders underwent radiography and standardized CT scans. The cohort comprised 10 type B1, 10 type B2, and 10 type B3 glenoids. PHHS was measured using the scapulohumeral subluxation method on axillary radiographs and 2D CT. On 3D CT, PHHS was measured volumetrically. PHHS was statistically compared between imaging modalities, with P ≤ .05 considered significant. Results The mean PHHS value for the entire group was 69% ± 24% on radiographs, 65% ± 23% with 2D CT, and 74% ± 24% with 3D volumetric CT. PHHS as measured on complete axillary radiographs was not significantly different than that measured on 2D CT (P = .941). Additionally, PHHS on 3D volumetric CT was 9.5% greater than that on 2D CT (P < .001). There were no significant differences in PHHS between the type B1, B2, and B3 groups with 2D or 3D CT measurement techniques (P > .102). Conclusion Significant differences in PHHS were found between measurement techniques (P < .035). A 9.5% difference in PHHS between 2D and 3D CT can be mostly accounted for by the linear (2D) vs. volumetric (3D) measurement techniques (a linear 80% PHHS value is mathematically equivalent to a volumetric PHHS value of 89.6%). Surgeons should be aware that subluxation values and therefore thresholds vary across different imaging modalities and measurement techniques.
Collapse
|
10
|
Three-dimensional geometry of the normal shoulder: a software analysis. J Shoulder Elbow Surg 2020; 29:e468-e477. [PMID: 32807728 DOI: 10.1016/j.jse.2020.03.042] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/02/2019] [Revised: 03/03/2020] [Accepted: 03/11/2020] [Indexed: 02/01/2023]
Abstract
BACKGROUND Three-dimensional (3D) geometry of the normal glenohumeral bone anatomy and relations is poorly documented. Our aims were (1) to determine the 3D geometry of the normal glenohumeral joint (GHJ) with reference to the scapular body plane and (2) to identify spatial correlations between the orientation and direction of the humeral head and the glenoid. METHODS Computed tomographies (CTs) of the normal, noninjured GHJ were collected from patients who had undergone CTs in the setting of (1) polytrauma, (2) traumatic head injury, (3) chronic acromioclavicular joint dislocations, and (4) unilateral trauma with a contralateral normal shoulder. We performed 3D segmentation and measurements with a fully automatic software (Glenosys; Imascap). Measurements were made in reference to the scapular body plane and its transverse axis. Geometric measurements included version, inclination, direction, orientation, best-fit sphere radius (BFSR), humeral subluxation, critical shoulder angle, reverse shoulder angle, glenoid area, and glenohumeral distance. Statistical correlations were sought between glenoid and humeral 3D measurements (Pearson correlation). RESULTS A total of 122 normal GHJs (64 men, 58 women, age: 52 ± 17 years) were studied. The glenoid BFSR was always larger than the humerus BFSR (constant factor of 1.5, standard deviation = 0.2). The mean glenoid version and inclination were -6° ± 4° and 7° ± 5°, respectively. Men and women were found to have significantly different values for inclination (6° vs. 9°, P = .02), but not for version. Humeral subluxation was 59% ± 7%, with a linear correlation with glenoid retroversion (r = -0.70, P < .001) regardless of age. There was a significant and linear correlation between glenoid and humeral orientation and direction (r = 0.72 and r = 0.70, P < .001). CONCLUSION The 3D geometry of the glenoid and humeral head present distinct limits in normal shoulders that can be set as references in daily practice: version and inclination are -6° and 7°, respectively, and humeral posterior subluxation is 59%; interindividual variations, regardless of the size, are relative to the scapular plane. There exists a strong correlation between the position of the humeral head and the glenoid orientation and direction.
Collapse
|
11
|
Glenoid subchondral bone density in osteoarthritis: A comparative study of asymmetric and symmetric erosion patterns. Orthop Traumatol Surg Res 2020; 106:1127-1134. [PMID: 32807698 DOI: 10.1016/j.otsr.2020.06.004] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/01/2019] [Revised: 05/07/2020] [Accepted: 06/02/2020] [Indexed: 02/03/2023]
Abstract
BACKGROUND Recent studies have shown variations in glenoid bone density in asymmetric wear patterns but have yet to analyze non-arthritic or concentrically worn glenoids. QUESTIONS/PURPOSES The purpose of this study is to characterize and compare subchondral glenoid bone densities in both non-arthritic and A1, A2, B1, B2 and B3 osteoarthritic glenoids, as well as to assess uniformity in symmetric and asymmetric erosion wear patterns. METHODS In all, 150 computerized tomography (CT) scans containing equal numbers of non-arthritic (N), A1, A2, B1, B2 and B3 glenoids were segmented semi-automatically. Each reconstructed glenoid was divided first into anterior and posterior quadrants, and then further subdivided into four quadrants. Volumes of interest (VOI) were defined at depths of 0-2.5mm (Zone A), 2.5-5mm (Zone B) and 5-7.5mm (Zone C). Average bone densities were measured at each VOI depth and in each quadrant. RESULTS Osteoarthritic glenoids had higher mean bone densities than N glenoids. Mean bone densities were uniform amongst all quadrants for N glenoids, but not for osteoarthritic glenoids. In A1 glenoids, the antero-superior quadrant was less dense in Zone C. A2 glenoids had increased bone density measured posteriorly in Zones B and C. In B1 and B2 glenoids, Zones B and C demonstrated increased bone densities of posterior quadrants compared to anterior quadrants. B3 glenoids presented similar results as A1 and A2 glenoids. Cystic changes were more pronounced in anterior quadrants of A2, B1, B2 and B3 glenoids. CONCLUSION This study demonstrates that osteoarthritic glenoids have greater bone density than non-arthritic glenoids, independent of depth of interest. It also confirms that N glenoids have uniform erosion wear patterns and that B1 and B2 glenoids have irregular wear patterns. It is the first study to reveal that A1, A2 and B3 glenoids, though geometrically symmetrical, have irregular bony densities similar to B2 glenoids. These findings have clinical implications for reaming the glenoid and implant fixation. LEVEL OF EVIDENCE Basic Science, Anatomy, Imaging.
Collapse
|
12
|
The reverse shoulder arthroplasty angle: a new measurement of glenoid inclination for reverse shoulder arthroplasty. J Shoulder Elbow Surg 2019; 28:1281-1290. [PMID: 30935825 DOI: 10.1016/j.jse.2018.11.074] [Citation(s) in RCA: 46] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/13/2018] [Revised: 11/26/2018] [Accepted: 11/30/2018] [Indexed: 02/01/2023]
Abstract
BACKGROUND Avoiding superior inclination of the glenoid component in reverse shoulder arthroplasty (RSA) is crucial. We hypothesized that superior inclination was underestimated in RSA. Our purpose was to describe and assess a new measurement of inclination for the inferior portion of the glenoid (where the baseplate rests). METHODS The study included 47 shoulders with rotator cuff tear arthropathy (mean age, 76 years). The reverse shoulder arthroplasty angle (RSA angle), defined as the angle between the inferior part of the glenoid fossa and the perpendicular to the floor of the supraspinatus, was compared with the global glenoid inclination (β angle or total shoulder arthroplasty [TSA] angle). Measurements were made on plain anteroposterior radiographs and reformatted 2-dimensional (2D) computed tomography (CT) scans by 3 independent observers and compared with 3-dimensional (3D) software (Glenosys) measurements. RESULTS The mean RSA angle was 25° ± 8° on plain radiographs, 20° ± 6° on reformatted 2D CT scans, and 21° ± 5° via 3D reconstruction software. The mean TSA angle was on average 10° ± 5° lower than the mean RSA angle (P < .001); this difference was observed regardless of the method of measurement (radiographs, 2D CT, or 3D CT) and type of glenoid erosion according to Favard. In Favard type E1 glenoids with central concentric erosion, the difference between the 2 angles was 12° ± 4° (P < .001). CONCLUSION The same angle cannot be used to measure glenoid inclination in anatomic and reverse prostheses. The TSA (or β) angle underestimates the superior orientation of the reverse baseplate in RSA. The RSA angle (20° ± 5°) needs to be corrected to achieve neutral inclination of the baseplate (RSA angle = 0°). Surgeons should be aware that E1 glenoids (with central erosion) are at risk for baseplate superior tilt if the RSA angle is not corrected.
Collapse
|
13
|
Abstract
BACKGROUND The Walch B3 glenoid is theorized to be a progression of the B2 biconcave pattern. The present study aimed to compare glenoid indices between B2 and B3 patterns. We hypothesized that the B3 pattern would have significantly worse retroversion, inclination and medialization. METHODS Computed tomography scans of 50 patients with B2 erosions [mean (SD) age 68 (9) years; 25 male] and 50 patients with B3 erosions [mean (SD) age 72 (8) years; 22 males] were converted into three-dimensional reconstructions. Retroversion, inclination, medialization and humeral head subluxation were compared. RESULTS The data demonstrated no statistically significant differences [mean (SD)] between groups when assessing retroversion: B2 = 21 (8)°, B3 = 24 (7)° (p = 0.602); glenoid inclination: B2 = 9 (6)°, B3 = 8 (6)° (p = 0.967); or medialization: B2 = 12 (4) mm, B3 = 14 (4) mm (p = 0.384). In the B2 group, the mean (SD) humeral head subluxation was 80% (10%) according to the scapular plane and 55% (9%) according to the glenoid plane, which was not statistically different from the B3 group with a mean (SD) humeral head subluxation of 81% (7%) according to the scapular plane (p = 0.680) and 54% (7%) according to the glenoid plane (p = 0.292). CONCLUSIONS These results demonstrated no significant differences between the B2 and B3 erosion patterns, with respect to the glenoid indicies measured. The aetiology of the B3 glenoid cannot be completely explained by progression of wear in a B2 glenoid.
Collapse
|
14
|
Glenosphere design affects range of movement and risk of friction-type scapular impingement in reverse shoulder arthroplasty. Bone Joint J 2018; 100-B:1182-1186. [DOI: 10.1302/0301-620x.100b9.bjj-2018-0264.r1] [Citation(s) in RCA: 38] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Aims Scapular notching is a frequently observed radiographic phenomenon in reverse shoulder arthroplasty (RSA), signifying impingement of components. The purposes of this study were to evaluate the effect of glenoid component size and glenosphere type on impingement-free range of movement (ROM) for extension and internal and external rotation in a virtual RSA model, and to determine the optimal configuration to reduce the incidence of friction-type scapular notching. Materials and Methods Preoperative CT scans obtained in 21 patients (three male, 18 female) with primary osteoarthritis were analyzed using modelling software. Two concurrent factors were tested for impingement-free ROM and translation of the centre of rotation: glenosphere diameter (36 mm vs 39 mm) and type (centred, 2 mm inferior eccentric offset, 10° inferior tilt). Results Glenosphere size was most predictive of increased extension and external rotation, whereas lateralization of the centre of rotation was the most predictive factor for internal rotation. A larger diameter of glenosphere combined with a 10° tilted configuration demonstrated superior values for extension and external rotation, whereas the eccentric component improved internal rotation by a mean 8.9° (standard deviation 2.7°) compared with a standard concentric glenosphere. Conclusion Glenosphere configuration can be modified to increase range of movement in RSA. Friction-type scapular notching was most effectively reduced by use of a large-diameter glenosphere with 10° inferior tilt. Cite this article: Bone Joint J 2018;100-B:1182–6.
Collapse
|
15
|
Abstract
Aims The Walch Type C dysplastic glenoid is characterized by excessive retroversion. This anatomical study describes its morphology. Patients and Methods A total of 29 shoulders with a dysplastic glenoid were analyzed. CT was used to measure retroversion, inclination, height, width, radius-of-curvature, surface area, depth, subluxation of the humeral head and the Goutallier classification of fatty infiltration. The severity of dysplasia and deficiency of the posterior rim of the glenoid were recorded. Results A type C glenoid occurred in 1.8% of shoulders referred to our tertiary centres. The mean retroversion, inclination, height, width, radius-of-curvature, surface area, and depth of the glenoid were 37°, 3°, 46 mm, 30 mm, 37°, 1284 mm3, and 16 mm, respectively. The mean posterior subluxation was 90%. The Goutallier class was < 2 in 25 shoulders (86%). Glenoid dysplasia was mild in four, moderate in 14, and severe in 11 shoulders. The typical appearance of the posterior glenoid rim had a rounded or ‘lazy J’ morphology. The glenoid neck was deficient in 18 shoulders (62%). Conclusion A dysplastic Type C glenoid characteristically has a uniconcave retroverted morphology, a deficient posteroinferior rim and scapular neck, and a reduced depth. These findings help to define the unique anatomical variations and may aid the planning of surgery and the development of components for these patients. Cite this article: Bone Joint J 2018;100-B:1074–9.
Collapse
|
16
|
Proper benefit of a three dimensional pre-operative planning software for glenoid component positioning in total shoulder arthroplasty. INTERNATIONAL ORTHOPAEDICS 2018; 42:2897-2906. [DOI: 10.1007/s00264-018-4037-1] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/03/2018] [Accepted: 06/12/2018] [Indexed: 10/28/2022]
|
17
|
Automated Three-Dimensional Measurement of Glenoid Version and Inclination in Arthritic Shoulders. J Bone Joint Surg Am 2018; 100:57-65. [PMID: 29298261 DOI: 10.2106/jbjs.16.01122] [Citation(s) in RCA: 68] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Preoperative computed tomography (CT) measurements of glenoid version and inclination are recommended for planning glenoid implantation in shoulder arthroplasty. However, current manual or semi-automated 2-dimensional (2D) and 3-dimensional (3D) methods are user-dependent and time-consuming. We assessed whether the use of a 3D automated method is accurate and reliable to measure glenoid version and inclination in osteoarthritic shoulders. METHODS CT scans of osteoarthritic shoulders of 60 patients scheduled for shoulder arthroplasty were obtained. Automated, surgeon-operated, image analysis software (Glenosys; Imascap) was developed to measure glenoid version and inclination. The anatomic scapular reference planes were defined as the mean of the peripheral points of the scapular body as well as the plane perpendicular to it, passing along the supraspinatus fossa line. Measurements were compared with those obtained using previously described manual or semi-automated methods, including the Friedman version angle on 2D CTs, Friedman method on 3D multiplanar reconstructions (corrected Friedman method), Ganapathi-Iannotti and Lewis-Armstrong methods on 3D volumetric reconstructions (for glenoid version), and Maurer method (for glenoid inclination).The mean differences (and standard deviation) and the concordance correlation coefficients (CCCs) were calculated. Two orthopaedic surgeons independently examined the images for the interobserver analysis, with one of them measuring them twice more for the intraobserver analysis; interobserver and intraobserver reliability was calculated using the intraclass correlation coefficients (ICCs). RESULTS The mean difference in the Glenosys glenoid version measurement was 2.0° ± 4.5° (CCC = 0.93) compared with the Friedman method, 2.5° ± 3.2° (CCC = 0.95) compared with the corrected Friedman method, 1.5° ± 4.5° (CCC = 0.94) compared with the Ganapathi-Iannotti method, and 1.8° ± 3.8° (CCC = 0.95) compared with the Lewis-Armstrong method. There was a mean difference of 0.2° ± 4.7° (CCC = 0.78) between the inclination measurements made with the Glenosys and Maurer methods. The difference between the overall average 2D and 3D measurements was not significant (p = 0.45). CONCLUSIONS Use of fully automated software for 3D measurement of glenoid version and inclination in arthritic shoulders is reliable and accurate, showing excellent correlation with previously described manual or semi-automated methods. CLINICAL RELEVANCE The use of automated surgeon-operated image analysis software to evaluate 3D glenoid anatomy eliminates interobserver and intraobserver discrepancies, improves the accuracy of preoperative planning for shoulder replacement, and offers a potential gain of time for the surgeon.
Collapse
|
18
|
The influence of humeral neck shaft angle and glenoid lateralization on range of motion in reverse shoulder arthroplasty. J Shoulder Elbow Surg 2017; 26:1726-1731. [PMID: 28528016 DOI: 10.1016/j.jse.2017.03.032] [Citation(s) in RCA: 99] [Impact Index Per Article: 14.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/11/2016] [Revised: 03/20/2017] [Accepted: 03/27/2017] [Indexed: 02/01/2023]
Abstract
BACKGROUND Recent developments in reverse shoulder arthroplasty (RSA) have focused on changes in several design-related parameters, including humeral component design, to allow for easier convertibility. Alterations in humeral inclination and offset on shoulder kinematics may have a relevant influence on postoperative outcome. This study used a virtual computer simulation to evaluate the influence of humeral neck shaft angle and glenoid lateralization on range of motion in onlay design RSA. METHODS Three-dimensional RSA computer templating was created from computed tomography (CT) scans in 20 patients undergoing primary total shoulder arthroplasty for concentric osteoarthritis (Walch A1). Two concurrent factors were tested for impingement-free range of motion: humeral inclination (135° vs. 145°) and glenoid lateralization (0 mm vs. 5 mm). RESULTS Decreasing the humeral neck shaft angle demonstrated a significant increase in impingement-free range of motion. Compared to the 145° configuration, extension was increased by 42.3° (-8.5° to 73.5°), adduction by 15° (10° to 23°), and external rotation with the arm at side by 15.1° (8.5° to 26.5°); however, abduction was decreased by 6.5° (-1° to 12.5°). Glenoid lateralization led to comparable results, but an additional increase in abduction of 7.6° (-1° to 16.5°) and forward flexion of 26.6° (6.5° to 62°) was observed. CONCLUSION Lower humeral neck shaft angle and glenoid lateralization are effective for improvement in range of motion after RSA. The use of the 135° model with 5 mm of glenoid lateralization provided the best results in impingement-free range of motion, except for abduction.
Collapse
|
19
|
Prediction of the pre-morbid 3D anatomy of the proximal humerus based on statistical shape modelling. Bone Joint J 2017; 99-B:927-933. [DOI: 10.1302/0301-620x.99b7.bjj-2017-0014] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/10/2017] [Accepted: 02/10/2017] [Indexed: 01/02/2023]
Abstract
Aims Restoring the pre-morbid anatomy of the proximal humerus is a goal of anatomical shoulder arthroplasty, but reliance is placed on the surgeon’s experience and on anatomical estimations. The purpose of this study was to present a novel method, ‘Statistical Shape Modelling’, which accurately predicts the pre-morbid proximal humeral anatomy and calculates the 3D geometric parameters needed to restore normal anatomy in patients with severe degenerative osteoarthritis or a fracture of the proximal humerus. Materials and Methods From a database of 57 humeral CT scans 3D humeral reconstructions were manually created. The reconstructions were used to construct a statistical shape model (SSM), which was then tested on a second set of 52 scans. For each humerus in the second set, 3D reconstructions of four diaphyseal segments of varying lengths were created. These reconstructions were chosen to mimic severe osteoarthritis, a fracture of the surgical neck of the humerus and a proximal humeral fracture with diaphyseal extension. The SSM was then applied to the diaphyseal segments to see how well it predicted proximal morphology, using the actual proximal humeral morphology for comparison. Results With the metaphysis included, mimicking osteoarthritis, the errors of prediction for retroversion, inclination, height, radius of curvature and posterior and medial offset of the head of the humerus were 2.9° (± 2.3°), 4.0° (± 3.3°), 1.0 mm (± 0.8 mm), 0.8 mm (± 0.6 mm), 0.7 mm (± 0.5 mm) and 1.0 mm (± 0.7 mm), respectively. With the metaphysis excluded, mimicking a fracture of the surgical neck, the errors of prediction for retroversion, inclination, height, radius of curvature and posterior and medial offset of the head of the humerus were 3.8° (± 2.9°), 3.9° (± 3.4°), 2.4 mm (± 1.9 mm), 1.3 mm (± 0.9 mm), 0.8 mm (± 0.5 mm) and 0.9 mm (± 0.6 mm), respectively. Conclusion This study reports a novel, computerised method that accurately predicts the pre-morbid proximal humeral anatomy even in challenging situations. This information can be used in the surgical planning and operative reconstruction of patients with severe degenerative osteoarthritis or with a fracture of the proximal humerus. Cite this article: Bone Joint J 2017;99-B:927–33.
Collapse
|
20
|
Patient-specific glenoid guides provide accuracy and reproducibility in total shoulder arthroplasty. Bone Joint J 2017; 98-B:1080-5. [PMID: 27482021 DOI: 10.1302/0301-620x.98b8.37257] [Citation(s) in RCA: 78] [Impact Index Per Article: 11.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/14/2015] [Accepted: 03/08/2016] [Indexed: 11/05/2022]
Abstract
AIMS Patient-specific glenoid guides (PSGs) claim an improvement in accuracy and reproducibility of the positioning of components in total shoulder arthroplasty (TSA). The results have not yet been confirmed in a prospective clinical trial. Our aim was to assess whether the use of PSGs in patients with osteoarthritis of the shoulder would allow accurate and reliable implantation of the glenoid component. PATIENTS AND METHODS A total of 17 patients (three men and 14 women) with a mean age of 71 years (53 to 81) awaiting TSA were enrolled in the study. Pre- and post-operative version and inclination of the glenoid were measured on CT scans, using 3D planning automatic software. During surgery, a congruent 3D-printed PSG was applied onto the glenoid surface, thus determining the entry point and orientation of the central guide wire used for reaming the glenoid and the introduction of the component. Manual segmentation was performed on post-operative CT scans to compare the planned and the actual position of the entry point (mm) and orientation of the component (°). RESULTS The mean error in the accuracy of the entry point was -0.1 mm (standard deviation (sd) 1.4) in the horizontal plane, and 0.8 mm (sd 1.3) in the vertical plane. The mean error in the orientation of the glenoid component was 3.4° (sd 5.1°) for version and 1.8° (sd 5.3°) for inclination. CONCLUSION Pre-operative planning with automatic software and the use of PSGs provides accurate and reproducible positioning and orientation of the glenoid component in anatomical TSA. Cite this article: Bone Joint J 2016;98-B:1080-5.
Collapse
|
21
|
A modification to the Walch classification of the glenoid in primary glenohumeral osteoarthritis using three-dimensional imaging. J Shoulder Elbow Surg 2016; 25:1601-6. [PMID: 27282738 DOI: 10.1016/j.jse.2016.03.010] [Citation(s) in RCA: 226] [Impact Index Per Article: 28.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/02/2015] [Revised: 02/26/2016] [Accepted: 03/13/2016] [Indexed: 02/01/2023]
Abstract
BACKGROUND Since Walch and colleagues originally classified glenoid morphology in the setting of glenohumeral osteoarthritis, several authors have reported varying levels of interobserver and intraobserver reliability. We propose several modifications to the Walch classification that we hypothesize will increase interobserver and intraobserver reliability. METHODS We propose the addition of the B3 and D glenoids and a more precise definition of the A2 glenoid. The B3 glenoid is monoconcave and worn preferentially in its posterior aspect, leading to pathologic retroversion of at least 15° or subluxation of 70%, or both. The D glenoid is defined by glenoid anteversion or anterior humeral head subluxation. The A2 glenoid has a line connecting the anterior and posterior native glenoid rims that transects the humeral head. Using 3-dimensional computed tomography glenoid reconstructions, 3 evaluators used the original Walch classification and the modified Walch classification to classify 129 nonconsecutive glenoids on 4 separate occasions. Reliabilities were assessed by calculating κ coefficients. RESULTS Interobserver reliabilities improved from an average of 0.391 (indicating fair agreement) using the original classification to an average of 0.703 (substantial agreement) using the modified classification. Intraobserver reliabilities improved from an average of 0.605 (moderate agreement) to an average of 0.882 (nearly perfect agreement). CONCLUSION When 3-dimensional glenoid reconstructions and the modified Walch classification described herein are used, improved interobserver and intraobserver reliabilities are obtained.
Collapse
|
22
|
Comparison of glenoid inclination angle using different clinical imaging modalities. J Shoulder Elbow Surg 2016; 25:180-5. [PMID: 26356363 DOI: 10.1016/j.jse.2015.07.001] [Citation(s) in RCA: 44] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/17/2014] [Revised: 06/26/2015] [Accepted: 07/08/2015] [Indexed: 02/01/2023]
Abstract
BACKGROUND The β-angle, formed by the intersection of a line on the floor of the supraspinatus fossa and glenoid fossa line, has been described as a reliable measurement tool in the clinical setting to analyze glenoid inclination on the anteroposterior (AP) view of the shoulder. The purpose of this study was to compare the accuracy of the β-angle measurement using different imaging modalities with a validated 3-dimensional (3D) software tool. MATERIALS AND METHODS The β-angle was measured on AP radiographs, unformatted 2-dimensional (2D) computed tomography (CT) scan, and reformatted 2D CT scan in the scapular plane for 51 shoulders of 49 patients undergoing primary total shoulder arthroplasty. Comparison to the glenoid inclination angle calculated by the 3D software was performed. RESULTS The β-angle measured on reformatted CT scan was found to be the most accurate measurement method, with a mean difference of 1° (standard deviation [SD], 0.5°) with respect to 3D measurement. On AP radiographs, the β-angle was not as accurate, with a mean difference of 3° (SD, 0.7°; P < .006). The β-angle on unformatted 2D CT scan was not a reliable method to measure glenoid inclination, with a mean difference of 10° (SD, 0.9°; P < .0001). CONCLUSION The β-angle measured with 2D CT scan formatted in the scapular plane was the most accurate method for measuring glenoid inclination. The β-angle on the AP radiograph is less accurate and reliable. Measurement of the β-angle on an unformatted 2D CT scan is not an acceptable method to determine glenoid inclination.
Collapse
|
23
|
Correlation between glenoid inclination and critical shoulder angle: a radiographic and computed tomography study. J Shoulder Elbow Surg 2015; 24:1948-53. [PMID: 26350880 DOI: 10.1016/j.jse.2015.07.013] [Citation(s) in RCA: 64] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/06/2015] [Revised: 07/22/2015] [Accepted: 07/23/2015] [Indexed: 02/01/2023]
Abstract
BACKGROUND Increased critical shoulder angles consist of both the acromial cover and glenoid inclination and have been found in patients with rotator cuff pathology. The purpose of this study was to determine the correlation of the critical shoulder angle and glenoid inclination and to determine the difference in glenoid inclination between patients with osteoarthritis and massive rotator cuff tears. METHODS The critical shoulder angle and glenoid inclination were measured on anteroposterior radiographs, and glenoid inclination was also measured on a validated 3-dimensional computer software program of 50 shoulders undergoing primary total shoulder arthroplasty. Twenty-five shoulders had osteoarthritis and A1 glenoids, as defined by the Walch classification, and were undergoing anatomic shoulder arthroplasty. The other 25 shoulders had massive rotator cuff tears and E0 glenoids, as defined by the Favard classification. The 2 groups were compared. RESULTS Critical shoulder angle and glenoid inclination were significantly correlated (R(2) = 0.7426, P < .001). Shoulders with massive rotator cuff tears (E0) demonstrated increased glenoid inclination measurements than shoulders with osteoarthritis (A1). As measured by the 3-dimensional software, the massive rotator cuff group had a glenoid inclination of 13.6° ± 4.3° and the osteoarthritis group had a glenoid inclination of 4.7° ± 5.6°. When measured by anteroposterior radiographs, the average glenoid inclination was 13.6° ± 4.6° in the massive rotator cuff group and was 7.6° ± 5.01° in the osteoarthritic group . CONCLUSION Glenoid inclination is linearly correlated with the critical shoulder angle and is significantly increased in patients with massive rotator cuff tears.
Collapse
|
24
|
Mesh correspondence improvement using Regional Affine Registration: Application to Statistical Shape Model of the scapula. Ing Rech Biomed 2015. [DOI: 10.1016/j.irbm.2015.06.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
25
|
Three-dimensional planning and use of patient-specific guides improve glenoid component position: an in vitro study. J Shoulder Elbow Surg 2015; 24:302-9. [PMID: 25183662 DOI: 10.1016/j.jse.2014.05.029] [Citation(s) in RCA: 138] [Impact Index Per Article: 15.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/13/2014] [Revised: 05/21/2014] [Accepted: 05/23/2014] [Indexed: 02/01/2023]
Abstract
BACKGROUND Glenoid component positioning is a key factor for success in total shoulder arthroplasty. Three-dimensional (3D) measurements of glenoid retroversion, inclination, and humeral head subluxation are helpful tools for preoperative planning. The purpose of this study was to assess the reliability and precision of a novel surgical method for placing the glenoid component with use of patient-specific templates created by preoperative surgical planning and 3D modeling. METHODS A preoperative computed tomography examination of cadaveric scapulae (N = 18) was performed. The glenoid implants were virtually placed, and patient-specific guides were created to direct the guide pin into the desired orientation and position in the glenoid. The 3D orientation and position of the guide pin were evaluated by performing a postoperative computed tomography scan for each scapula. The differences between the preoperative planning and the achieved result were analyzed. RESULTS The mean error in 3D orientation of the guide pin was 2.39°, the mean entry point position error was 1.05 mm, and the mean inclination angle error was 1.42°. The average error in the version angle was 1.64°. There were no technical difficulties or complications related to use of patient-specific guides for guide pin placement. Quantitative analysis of guide pin positioning demonstrated a good correlation between preoperative planning and the achieved position of the guide pin. CONCLUSION This study demonstrates the reliability and precision of preoperative planning software and patient-specific guides for glenoid component placement in total shoulder arthroplasty.
Collapse
|
26
|
Recognition-based segmentation and registration method for image guided shoulder surgery. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2012; 2011:6212-5. [PMID: 22255758 DOI: 10.1109/iembs.2011.6091534] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
For any image guided surgery, independently of the technique which is used (navigation, templates, robotics), it is necessary to get a 3D bone surface model from CT or MR images. Such model is used for planning, registration and visualization. We report that graphical representation of patient bony structure and the surgical tools, interconnectively with the tracking device and patient-to-image registration are crucial components in such a system. For Total Shoulder Arthroplasty (TSA), there are many challenges, The most of cases that we are working with are pathological cases such as rheumatoid arthritis, osteoarthritis disease. The CT images of these cases often show a fusion area between the glenoid cavity and the humeral head. They also show severe deformations of the humeral head surface that result in a loss of contours. This fusion area and image quality problems are also amplified by well-known CT-scan artifacts like beam-hardening or partial volume effects. The state of the art shows that several segmentation techniques, applied to CT-Scans of the shoulder, have already been disclosed. Unfortunately, their performances, when used on pathological data, are quite poor [1, 2]. The aim of this paper is to present a new image guided surgery system based on CT scan of the patient and using bony structure recognition, morphological analysis for the operated region and robust image-to-patient registration.
Collapse
|