1
|
Early patellofemoral cartilage and bone pathology in a rat model of noninvasive anterior cruciate ligament rupture. Connect Tissue Res 2023; 64:175-185. [PMID: 36318110 DOI: 10.1080/03008207.2022.2136571] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/31/2022] [Revised: 10/04/2022] [Accepted: 10/11/2022] [Indexed: 02/03/2023]
Abstract
OBJECTIVE Anterior cruciate ligament rupture (ACLR) is a risk factor for the development of post-traumatic osteoarthritis (PTOA). While PTOA in the tibiofemoral joint compartment is well-characterized, very little is known about pathology in the patellofemoral compartment after ACL injury. Here, we evaluated the extent to which ACLR induces early patellofemoral joint damage in a rat model. METHODS Adult female Lewis rats were randomized to noninvasive ACLR or Sham. Two weeks post-injury, contrast-enhanced micro-computed tomography (µCT) of femoral and patellar cartilage was performed using 20% v/v ioxaglate. Morphometric parameters of femoral trochlear and patellar cartilage, subchondral bone, and trabecular bone were derived from µCT. Sagittal Safranin-O/Fast-Green-stained histologic sections were graded using the OARSI score in a blinded fashion. RESULTS Cartilage and bone remodelling consistent with an early PTOA phenotype were observed in both femoral trochleas and patellae. ACLR caused osteophyte formation of the patella and pathology in the superficial zone of articular cartilage, including surface fibrillation, fissures, increased cellularity, and abnormal chondrocyte clustering. There were significant increases in thickness of patellar and trochlear cartilage. Loss of subchondral bone thickness, bone volume fraction, and tissue mineral density, as well as changes to patellar and trochlear trabecular microarchitecture, were indicative of catabolic bone remodelling. Several injury-induced changes, including increased cartilage thickness and trabecular spacing and decreased trabecular number were more severe in the patella compared to the trochlea. CONCLUSION The patellofemoral joint develops mild but evident pathology in the early period following ACL rupture, extending the utility of this model to the study of patellofemoral PTOA.
Collapse
|
2
|
Traumatic joint injury induces acute catabolic bone turnover concurrent with articular cartilage damage in a rat model of posttraumatic osteoarthritis. J Orthop Res 2021; 39:1965-1976. [PMID: 33146410 DOI: 10.1002/jor.24903] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2020] [Revised: 09/18/2020] [Accepted: 10/31/2020] [Indexed: 02/04/2023]
Abstract
Assess acute alterations in bone turnover, microstructure, and histomorphometry following noninvasive anterior cruciate ligament rupture (ACLR). Twelve female Lewis rats were randomized to receive noninvasive ACLR or Sham loading (n = 6/group). In vivo μCT was performed at 3, 7, 10, and 14 days postinjury to quantify compartment-dependent subchondral (SCB) and epiphyseal trabecular bone remodeling. Near-infrared (NIR) molecular imaging was used to measure in vivo bone anabolism (800 CW BoneTag) and catabolism (Cat K 680 FAST). Metaphyseal bone remodeling and articular cartilage morphology was quantified using ex vivo μCT and contrast-enhanced µCT, respectively. Calcein-based dynamic histomorphometry was used to quantify bone formation. OARSI scoring was used to assess joint degeneration, and osteoclast number was quantified on TRAP stained-sections. ACLR induced acute catabolic bone remodeling in subchondral, epiphyseal, and metaphyseal compartments. Thinning of medial femoral condyle (MFC) SCB was observed as early as 7 days postinjury, while lateral femoral condyles (LFCs) exhibited SCB gains. Trabecular thinning was observed in MFC epiphyseal bone, with minimal changes to LFC. NIR imaging demonstrated immediate and sustained reduction of bone anabolism (~15%-20%), and a ~32% increase in bone catabolism at 14 days, compared to contralateral limbs. These findings were corroborated by reduced bone formation rate and increased osteoclast numbers, observed histologically. ACLR-injured femora had significantly elevated OARSI score, cartilage thickness, and cartilage surface deviation. ACL rupture induces immediate and sustained reduction of bone anabolism and overactivation of bone catabolism, with mild-to-moderate articular cartilage damage at 14 days postinjury.
Collapse
|
3
|
Longitudinal characterization of intervertebral disc remodeling following acute annular injury in a rat model of degenerative disc disease. Connect Tissue Res 2020; 61:568-576. [PMID: 31232119 DOI: 10.1080/03008207.2019.1635589] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Objective: Characterize 3D remodeling of the rat intervertebral disc (IVD) following acute annular injury via in vivo micro-computed tomography (µCT), ex vivo contrast-enhanced (CE)-µCT, and histology. Design: Female Lewis rats (N = 4/group) underwent either sham surgery or anterior annular puncture to L3-L4 and L5-L6 (n = 8 IVDs/group) to induce IVD degeneration. Rats were allowed ad libidum cage activity before and after surgery and underwent in vivo µCT scanning at baseline and every 2 weeks post-op for 12 weeks to characterize longitudinal changes in IVD height. At 12 weeks, lumbar spines were dissected and underwent CE-µCT scanning to characterize endpoint glycosaminoglycan distribution and nucleus pulposus (NP) volume ratio. Spines were processed for safranin-O-stained sagittal histology, and IVD degeneration was graded via the Rutges scale. Results: Puncture IVDs exhibited loss of IVD height at all time points from 4 weeks onward compared to Sham-the most severe height loss occurred posteriorly, with significant changes also occurring in the NP and laterally. Puncture IVDs exhibited higher CE-µCT attenuation, indicative of lower glycosaminoglycan content, and reduced NP volume ratio compared to Sham. Histologically, Puncture IVDs had higher Rutges damage scores and exhibited reduced NP cellularity and hydration, disorganized annulus fibrosus (AF) lamellae with evidence of the stab tract, and indistinct AF-NP border compared to Sham. Conclusions: Characterization of the complex, 3D alterations involved in the onset and early progression of IVD degeneration can foster greater understanding of the pathoetiology of IVD degeneration and may inform future studies assessing more sensitive diagnostic techniques or novel therapies.
Collapse
|
4
|
Automated MicroCT-based bone and articular cartilage analysis using iterative shape averaging and atlas-based registration. Bone 2020; 137:115417. [PMID: 32416288 DOI: 10.1016/j.bone.2020.115417] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/08/2019] [Revised: 05/02/2020] [Accepted: 05/12/2020] [Indexed: 01/09/2023]
Abstract
Micro-computed tomography (μCT) and contrast-enhanced μCT are important tools for preclinical analysis of bone and articular cartilage (AC). Quantitative data from these modalities is highly dependent on the accuracy of tissue segmentations, which are often obtained via time-consuming manual contouring and are prone to inter- and intra-observer variability. Automated segmentation strategies could mitigate these issues, but few such approaches have been described in the context of μCT. Here, we validated a fully-automated strategy for bone and AC segmentation based on registration of an average tissue atlas. Femora from healthy and arthritic rats underwent μCT scanning, and epiphyseal trabecular bone and AC volumes were manually contoured by an expert. Average tissue atlases composed of 1, 3, 5, 10 and 20 pre-contoured training images (n = 10 atlases/group) were generated using iterative shape averaging and registered onto unknown images via affine and non-rigid registration. Atlas-based and expert-defined volumes for bone and AC were compared in terms of shape-based similarity metrics, as well as morphometric and densitometric parameters. Our results demonstrate that atlas-based registrations were capable of highly accurate and consistent segmentation. Atlases built from as few as 3 training images had no incidence of mal-registration and exhibited improved incidence of accurate registration, and higher sensitivity and specificity compared to atlases built from only one training image. Atlas-based segmentation of bone and AC from μCT images is a robust and accurate alternative to manual tissue segmentation, enabling faster, more consistent segmentation of pre-clinical datasets.
Collapse
|
5
|
Error introduced by common reorientation algorithms in the assessment of rodent trabecular morphometry using micro-computed tomography. J Orthop Res 2018; 36:2762-2770. [PMID: 29744917 DOI: 10.1002/jor.24039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/10/2017] [Accepted: 04/17/2018] [Indexed: 02/04/2023]
Abstract
Quantitative analyses of bone using micro-computed tomography (μCT) are routinely employed in preclinical research, and virtual image reorientation to a consistent reference frame is a common processing step. The purpose of this study was to quantify error introduced by common reorientation algorithms in μCT-based characterization of bone. Mouse and rat tibial metaphyses underwent μCT scanning at a range of resolutions (6-30 μm). A trabecular volume-of-interest (VOI) was manually selected. Image stacks were analyzed without rotation, following 45° In-Plane axial rotation, and following 45° Triplanar rotation. Interpolation was performed using Nearest-Neighbor, Linear, and Cubic interpolations. Densitometric (bone volume fraction, tissue mineral density, bone mineral density) and morphometric variables (trabecular thickness, trabecular spacing, trabecular number, structural model index) were computed for each combination of voxel size, rotation, and interpolation. Significant reorientation error was measured in all parameters, and was exacerbated at higher voxel sizes, with relatively low error at 6 and 12 μm (max. reorientation error in BV/TV was 2.9% at 6 μm, 7.7% at 12 μm and 36.5% at 30 μm). Considering densitometric parameters, Linear and Cubic interpolations introduced significant error while Nearest-Neighbor interpolation caused minimal error, and In-Plane rotation caused greater error than Triplanar. Morphometric error was strongly and intricately dependent on the combination of rotation and interpolation employed. Reorientation error can be eliminated by avoiding reorientation altogether or by "de-rotating" VOIs from reoriented images back to the original reference frame prior to analysis. When these are infeasible, reorientation error can be minimized through sufficiently high resolution scanning, careful selection of interpolation type, and consistent processing of all images. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:2762-2770, 2018.
Collapse
|
6
|
Nondestructive, indirect assessment of the biomechanical properties of the rat intervertebral disc using contrast-enhanced μCT. J Orthop Res 2018; 36:2030-2038. [PMID: 29314237 DOI: 10.1002/jor.23850] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/20/2017] [Accepted: 12/24/2017] [Indexed: 02/04/2023]
Abstract
Mechanical characterization of the intervertebral disc involves labor-intensive and destructive experimental methodology. Contrast-enhanced micro-computed tomography is a nondestructive imaging modality for high-resolution visualization and glycosaminoglycan quantification of cartilaginous tissues. The purpose of this study was to determine whether anionic and cationic contrast-enhanced micro-computed tomography of the intervertebral disc can be used to indirectly assess disc mechanical properties in an ex vivo model of disc degeneration. L3/L4 motion segments were dissected from female Lewis rats. To deplete glycosaminoglycan, samples were treated with 0 U/ml (Control) or 5 U/ml papain. Contrast-enhanced micro-computed tomography was performed following incubation in 40% Hexabrix (anionic) or 30 mg I/ml CA4+ (cationic) for 24 h (n = 10/contrast agent/digestion group). Motion segments underwent cyclic mechanical testing to determine compressive and tensile modulus, stiffness, and hysteresis. Glycosaminoglycan content was determined using the dimethylmethylene blue assay. Correlations between glycosaminoglycan content, contrast-enhanced micro-computed tomography attenuation, and mechanical properties were assessed via the Pearson correlation. The predictive accuracy of attenuation on compressive properties was assessed via repeated random sub-sampling cross validation. Papain digestion produced significant decreases in glycosaminoglycan content and corresponding differences in attenuation and mechanical properties. Attenuation correlated significantly to glycosaminoglycan content and to all compressive mechanical properties using both Hexabrix and CA4+ . Predictive linear regression models demonstrated a predictive accuracy of attenuation on compressive modulus and stiffness of 79.8-86.0%. Contrast-enhanced micro-computed tomography was highly predictive of compressive mechanical properties in an ex vivo simulation of disc degeneration and may represent an effective modality for indirectly assessing disc compressive properties. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:2030-2038, 2018.
Collapse
|
7
|
Quantitative evaluation of retrieved reverse total shoulder arthroplasty liner surface deviation and volumetric wear. J Orthop Res 2018; 36:2007-2014. [PMID: 29314184 DOI: 10.1002/jor.23849] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/29/2017] [Accepted: 01/02/2018] [Indexed: 02/04/2023]
Abstract
Polyethylene wear is a known complication in total joint arthroplasty, however, in vivo wear rates in reverse total shoulder arthroplasty (RTSA) remain largely unknown. This study aimed to quantify volumetric and surface deviation changes in retrieved RTSA humeral liners using a novel micro-computed tomography (μCT)-based technique. After IRB-approval, 32 humeral liners (single manufacturer and model) with term-of-service greater than 90 days were analyzed. Clinical demographics and surgical data were collected via chart review. Unworn liners were used as geometric controls. Retrieved and unworn liners underwent μCT scanning. Retrieved liner volumes were isolated, co-registered to controls of matching geometry, and surface deviations of the articulation surface and rim were computed. Differences in total volume loss (TVL), volumetric wear rate (VWR), and surface deviation were reported. Semi-quantitative grading evaluated rim damage presence and severity. Mean term-of-service for all liners was 2.07 ± 1.33 years (range: 0.30-4.73). Mean TVL and VWR were 181.3 ± 208.2 mm3 and 114.5 ± 160.3 mm3 /year, respectively. Mean articulation and rim surface deviations were 0.084 ± 0.065 and 0.177 ± 0.159 mm, respectively. Articulation surface deviation was positively correlated to term-of-service. Rim damage was present on 63% of liners and correlated significantly to rim surface deviation. This study reports in vivo wear rates of retrieved RTSA implants. Our results demonstrate volumetric and articulation surface wear in select RTSA liners that is correlated to term-of-service. Calculation of in vivo wear rates can help bridge the gap between clinical outcomes and experimental models such as wear simulations and computational models. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:2007-2014, 2018.
Collapse
|
8
|
Effect of Bisphosphonate Pretreatment on Fresh Osteochondral Allografts: Analysis of In Vitro Graft Structure and In Vivo Osseous Incorporation. Orthopedics 2018; 41:e376-e382. [PMID: 29570765 DOI: 10.3928/01477447-20180320-04] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/07/2017] [Accepted: 01/22/2018] [Indexed: 02/03/2023]
Abstract
Fresh allograft transplantation of osteochondral defects restores functional articular cartilage and subchondral bone; however, rapid loss of chondrocyte viability during storage and osteoclast-mediated bone resorption at the graft-host interface after transplantation negatively impact outcomes. The authors present a pilot study evaluating the in vitro and in vivo impact of augmenting storage media with bisphosphonates. Forty cylindrical osteochondral cores were harvested from femoral condyles of human cadaveric specimens and immersed in either standard storage media or storage media supplemented with nitrogenated or non-nitrogenated bisphosphonates. Maintenance of graft structure and chondrocyte viability were assessed at 3 time points. A miniature swine trochlear defect model was used to evaluate the influence of bisphosphonate-augmented storage media on in vivo incorporation of fresh osteochondral tissue, which was quantified via μCT and decalcified histology. In the in vitro study, Safranin-O/Fast Green staining showed that both low- and high-dose nitrogenated-treated grafts retained chondrocyte viability and cartilage matrix for up to 43 days of storage. Allografts stored in nitrogenated-augmented storage media showed both μCT and histologic evidence of enhanced in vivo bony and cartilaginous incorporation in the miniature swine trochlear defect model. Several preclinical studies have shown the potential for enhanced storage of fresh osteochondral allografts via additions of relatively common drugs and biomolecules. This study showed that supplementing standard storage media with nitrogenated bisphosphonates may improve maintenance of chondrocyte viability and graft structure during cold storage as well as enhance in vivo osseous and cartilaginous incorporation of the graft. [Orthopedics: 2018; 41(3):e376-e382.].
Collapse
|
9
|
Articular cartilage surface roughness as an imaging-based morphological indicator of osteoarthritis: A preliminary investigation of osteoarthritis initiative subjects. J Orthop Res 2017; 35:2755-2764. [PMID: 28460415 DOI: 10.1002/jor.23588] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/27/2016] [Accepted: 04/24/2017] [Indexed: 02/04/2023]
Abstract
Current imaging-based morphometric indicators of osteoarthritis (OA) using whole-compartment mean cartilage thickness (MCT) and volume changes can be insensitive to mild degenerative changes of articular cartilage (AC) due to areas of adjacent thickening and thinning. The purpose of this preliminary study was to evaluate cartilage thickness-based surface roughness as a morphometric indicator of OA. 3D magnetic resonance imaging (MRI) datasets were collected from osteoarthritis initiative (OAI) subjects with Kellgren-Lawrence (KL) OA grades of 0, 2, and 4 (n = 10/group). Femoral and tibial AC volumes were converted to two-dimensional thickness maps, and MCT, arithmetic surface roughness (Sa ), and anatomically normalized Sa (normSa ) were calculated. Thickness maps enabled visualization of degenerative changes with increasing KL grade, including adjacent thinning and thickening on the femoral condyles. No significant differences were observed in MCT between KL grades. Sa was significantly higher in KL4 compared to KL0 and KL2 in the whole femur (KL0: 0.55 ± 0.10 mm, KL2: 0.53 ± 0.09 mm, KL4: 0.79 ± 0.18 mm), medial femoral condyle (KL0: 0.42 ± 0.07 mm, KL2: 0.48 ± 0.07 mm, KL4: 0.76 ± 0.22 mm), and medial tibial plateau (KL0: 0.42 ± 0.07 mm, KL2: 0.43 ± 0.09 mm, KL4: 0.68 ± 0.27 mm). normSa was significantly higher in KL4 compared to KL0 and KL2 in the whole femur (KL0: 0.22 ± 0.02, KL2: 0.22 ± 0.02, KL4: 0.30 ± 0.03), medial condyle (KL0: 0.17 ± 0.02, KL2: 0.20 ± 0.03, KL4: 0.29 ± 0.06), whole tibia (KL0: 0.34 ± 0.04, KL2: 0.33 ± 0.05, KL4: 0.48 ± 0.11) and medial plateau (KL0: 0.23 ± 0.03, KL2: 0.24 ± 0.04, KL4: 0.40 ± 0.10), and significantly higher in KL2 compared to KL0 in the medial femoral condyle. Surface roughness metrics were sensitive to degenerative morphologic changes, and may be useful in OA characterization and early diagnosis. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2755-2764, 2017.
Collapse
|
10
|
Neer Award 2017: wear rates of 32-mm and 40-mm glenospheres in a reverse total shoulder arthroplasty wear simulation model. J Shoulder Elbow Surg 2017; 26:2029-2037. [PMID: 28893545 DOI: 10.1016/j.jse.2017.06.036] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/08/2017] [Revised: 06/14/2017] [Accepted: 06/19/2017] [Indexed: 02/01/2023]
Abstract
BACKGROUND Larger glenosphere diameters have been used recently to increase prosthesis stability and impingement-free range of motion in reverse total shoulder arthroplasty. The goal of this study was to evaluate the rate of polyethylene wear for 32-mm and 40-mm glenospheres. METHODS Glenospheres (32 mm and 40 mm, n = 6/group) and conventional polyethylene humeral liners underwent a 5-million cycle (MC) wear simulation protocol. Abduction-adduction and flexion-extension motion profiles were alternated every 250,000 cycles. At each interval, mass loss was determined and converted to volume loss and wear rate. At 0, 2.5 MC, and 5 MC, liners were imaged using micro-computed tomography to determine surface deviation. White light interferometry was performed on liners and glenospheres at 0 and 5 MC to quantify surface roughness. Wear particle morphology was characterized by environmental scanning electron microscopy. RESULTS Total volume loss was significantly higher in 40-mm liners from 1.5 MC onward (P < .05). Overall, volumetric wear rate was significantly higher in 40-mm liners compared with 32-mm glenospheres (81.7 ± 23.9 mm3/MC vs. 68.0 ± 18.9 mm3/MC; P < .001). However, micro-computed tomography surface deviation results demonstrated increased linear penetration on 32-mm glenospheres compared with 40-mm glenospheres (0.36 ± 0.03 µm vs. 0.28 ± 0.01 µm; P = .002). Surface roughness measurements showed no difference for liners; however, increased roughness was noted for 40-mm glenospheres at 5 MC compared with 32 mm (P < .05). CONCLUSION Larger glenospheres underwent significantly greater polyethylene volume loss and volumetric wear rates, whereas smaller glenospheres underwent greater polyethylene surface deviations. The enhanced stability provided by larger glenospheres must be weighed against the potential for increased polyethylene wear.
Collapse
|
11
|
Acute mobilization and migration of bone marrow-derived stem cells following anterior cruciate ligament rupture. Osteoarthritis Cartilage 2017; 25:1335-1344. [PMID: 28284998 DOI: 10.1016/j.joca.2017.03.004] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/24/2016] [Revised: 02/21/2017] [Accepted: 03/01/2017] [Indexed: 02/02/2023]
Abstract
OBJECTIVE Little is known regarding acute local and systemic processes following anterior cruciate ligament (ACL) rupture. No study has elucidated whether bone marrow-derived mesenchymal stem cells (MSCs) are mobilized into circulation and recruited to the injured joint. METHODS In Part 1, Lewis rats were randomized to noninvasive ACL rupture (Rupture) or non-injured (Control) (n = 6/group). After 72 h, whole blood MSC concentration was assessed using flow cytometry. Synovial fluid and serum were assayed for stromal cell-derived factor (SDF)-1α and cartilage degeneration biomarkers, respectively. In Part 2, 12 additional rats were randomized and intravenously-injected with fluorescently-labeled allogenic MSCs. Cell tracking was performed using longitudinal, in vivo and ex vivo near-infrared (NIR) imaging and histology. Synovium SDF-1α and interleukin (IL)-17A immunostaining was performed. Serum was assayed for SDF-1α and 29 other cytokines. RESULTS In Part 1, there was a significant increase in MSC concentration and synovial fluid SDF-1α in Rupture. No differences in cartilage biomarkers were observed. In Part 2, Rupture had significantly higher NIR signal at 24, 48, and 72 h, indicating active recruitment of MSCs to the injured joint. Ex vivo cell tracking demonstrated MSC localization in the synovium and myotendinous junction (MTJ) of the quadriceps. Injured synovia exhibited increased synovitis grade and higher degree of IL-17A and SDF-1α immunostaining. CONCLUSION ACL rupture induced peripheral blood mobilization of MSCs and migration of intravenously-injected allogenic MSCs to the injured joint, where they localized in the synovium and quadriceps MTJ.
Collapse
|
12
|
Contrast-enhanced μCT of the intervertebral disc: A comparison of anionic and cationic contrast agents for biochemical and morphological characterization. J Orthop Res 2017; 35:1067-1075. [PMID: 27415967 DOI: 10.1002/jor.23364] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/29/2016] [Accepted: 07/02/2016] [Indexed: 02/04/2023]
Abstract
The objective of this study was to quantify and compare the contrast-enhancing properties of the anionic contrast agent ioxaglate/Hexabrix, and cationic contrast agent CA4+ for biochemical and morphological characterization of the intervertebral disc (IVD) via μCT. Optimal contrast agent concentrations were determined by incubating rat lumbar IVDs in dilutions of Hexabrix-320 (20%, 30%, 40%, and 50%) and CA4+ (10, 20, 30, and 40 mg I/ml). μCT imaging was performed at 70 kVp, 114 μA, and 250 ms integration time, 12 μm voxel size. The kinetics of contrast enhancement were quantified with cumulative incubations for 0.5, 1, 2, 12, 16, 20, and 24 h using both agents. Agreement in morphological quantification was assessed via serial scans of the same IVDs. Correlation of attenuation to glycosaminoglycan (GAG) content was determined by enzymatic digestion of IVDs, subsequent μCT imaging, and GAG quantification via dimethylmethylene blue assay. Forty percent Hexabrix and 30 mg I/ml CA4+ were chosen as optimal concentrations. Hexabrix enabled greater delineation of the IVD from surrounding tissues, and CA4+ had the lowest uptake in surrounding soft tissue. Twenty-four hour incubation was sufficient for >99% equilibration of both agents. A high level of agreement was observed in the quantification of IVD volume (ICC = 0.951, r = 0.997) and height (ICC = 0.947, r = 0.991). Both agents exhibited strong linear correlations between μCT attenuation and GAG content (Hexabrix: r = -0.940; CA4+ : r = 0.887). Both agents enable biochemical and morphological quantification of the IVD via contrast-enhanced μCT and are effective tools for preclinical characterization. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1067-1075, 2017.
Collapse
|
13
|
The influence of testing angle on the biomechanical properties of the rat supraspinatus tendon. J Biomech 2016; 49:4159-4163. [DOI: 10.1016/j.jbiomech.2016.11.003] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2016] [Revised: 10/28/2016] [Accepted: 11/02/2016] [Indexed: 11/26/2022]
|
14
|
Surface roughness and thickness analysis of contrast-enhanced articular cartilage using mesh parameterization. Osteoarthritis Cartilage 2016; 24:290-8. [PMID: 26455998 DOI: 10.1016/j.joca.2015.09.006] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2015] [Revised: 09/03/2015] [Accepted: 09/11/2015] [Indexed: 02/02/2023]
Abstract
OBJECTIVE Articular cartilage (AC) morphology is an important metric for characterizing degeneration. We propose a novel morphologic analysis using mesh parameterization, enabling the use of surface roughness and thickness metrics to characterize degeneration in a rodent model of post-traumatic osteoarthritis. METHODS Six rats underwent anterior cruciate ligament transection (ACL-T) and six were controls (Control). At 4-weeks, femora and tibiae were harvested and imaged using contrast-enhanced micro-computed tomography (μCT). Cartilage surfaces were manually outlined, and 2-dimensional thickness maps were generated using mesh parameterization and analyzed by thickness and surface roughness (Sa). The parameterization technique was validated against the direct distance transform (DDT) and histologic AC thickness from sagittal Safranin-O/Fast-Green sections. Parameterization and DDT measurements were also validated using known, virtual shapes with zero, one, and two planes of curvature. RESULTS Parameterization had 0.00-6.26% error and DDT had 5.06-12.02% error in determining thicknesses of known shapes. Parameterization thickness correlated highly to DDT thickness (femur: r = 0.978, P < 0.001; tibia: r = 0.992, P < 0.001) and histologic thickness (femur: r = 0.952, P < 0.001; tibia: r = 0.959, P < 0.001). Thickness maps enabled visualization and quantification of AC degeneration. ACL-T samples displayed general thickening of cartilage, with adjacent regions of thickening and thinning on the medial femoral condyle. Compared to Control, ACL-T thickness was higher in the whole femur, whole tibia, and all compartments and sub-compartments. Sa was higher in the whole femur and medial and lateral condyle, and the whole tibia and medial and lateral plateau. The largest increases in Sa were observed on the medial femoral condyle. CONCLUSIONS Cartilage analysis using parameterization effectively characterized early degeneration in AC, including sub-compartmental thickening/thinning, and is a powerful tool for assessing degeneration in preclinical osteoarthritis.
Collapse
|
15
|
Wear rates of retentive versus nonretentive reverse total shoulder arthroplasty liners in an in vitro wear simulation. J Shoulder Elbow Surg 2015; 24:1372-9. [PMID: 25842031 DOI: 10.1016/j.jse.2015.02.016] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/07/2014] [Revised: 02/10/2015] [Accepted: 02/16/2015] [Indexed: 02/01/2023]
Abstract
BACKGROUND Although short-term outcomes of reverse total shoulder arthroplasty (rTSA) remain promising, the most commonly cited complication remains prosthetic instability. A retentive rTSA liner is commonly used to increase system constraint; however, no studies have evaluated the rate of polyethylene wear. Our hypothesis was that more constrained retentive liners would have higher wear rates than nonretentive liners. METHODS Six nonretentive and six retentive rTSA non-cross-linked polyethylene liners were subjected to 4.5 million cycles of alternating cycles of abduction-adduction and flexion-extension motion loading profiles. The rTSA liners were assessed for gravimetric wear loss, 3-dimensional volumetric loss by novel micro-computed tomography analysis, and particulate wear debris analysis. RESULTS Volumetric wear rates were significant at 7 specific time points (1.0, 2.0, 2.5, 3.25, 3.75, 4.0, and 4.5 million cycles) throughout testing between nonretentive and retentive liners; however, overall mean volumetric wear rate was not statistically significant (P = .076). Total volume loss between liner test groups was found to be significant starting after 3.5 million cycles of testing. Maximum and mean surface deviations were found to be larger for retentive liners vs. nonretentive liners by micro-computed tomography analysis across the entire articulation surface. DISCUSSION AND CONCLUSION Retentive liners undergo significantly greater volume loss and greater surface deviation compared with nonretentive liners, most notably at later time points representing extended implantation times. Additional stability afforded by retentive liners should be balanced against the potential for increased wear and potential for subsequent polyethylene wear-induced aseptic loosening.
Collapse
|
16
|
Wear rates of highly cross-linked polyethylene humeral liners subjected to alternating cycles of glenohumeral flexion and abduction. J Shoulder Elbow Surg 2015; 24:143-9. [PMID: 25037062 DOI: 10.1016/j.jse.2014.05.001] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/17/2013] [Revised: 04/30/2014] [Accepted: 05/04/2014] [Indexed: 02/01/2023]
Abstract
BACKGROUND Although short-term outcomes of reverse total shoulder arthroplasty have been promising, long-term success may be limited due to device-specific complications, including scapular notching. Scapular notching has been explained primarily as mechanical erosion; however, the generation of wear debris may lead to further biologic changes contributing to the severity of scapular notching. METHODS A 12-station hip simulator was converted to a reverse total shoulder arthroplasty wear simulator subjecting conventional and highly cross-linked ultra-high-molecular-weight polyethylene humeral liners to 5 million cycles of alternating abduction-adduction and flexion-extension loading profiles. RESULTS Highly cross-linked polyethylene liners (36.5 ± 10.0 mm(3)/million cycle) exhibited significantly lower volumetric wear rates compared with conventional polyethylene liners (83.6 ± 20.6 mm(3)/million cycle; P < .001). The flexion-extension loading profile exhibited significantly higher wear rates for conventional (P < .001) and highly cross-linked polyethylene (P < .001) compared with the abduction-adduction loading profile. Highly cross-linked wear particles had an equivalent circle diameter significantly smaller than wear particles from conventional polyethylene (P < .001). CONCLUSIONS Highly cross-linked polyethylene liners significantly reduced polyethylene wear and subsequent particle generation. More favorable wear properties with the use of highly cross-linked polyethylene may lead to increased device longevity and fewer complications but must be weighed against the effect of reduced mechanical properties.
Collapse
|
17
|
Comment on "Educating our students about pharmaceutical care for those living with cancer". AMERICAN JOURNAL OF PHARMACEUTICAL EDUCATION 2012; 76:181. [PMID: 23193345 PMCID: PMC3508495 DOI: 10.5688/ajpe769181] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
|
18
|
|
19
|
NONEMPIRICAL MOLECULAR ORBITAL THEORY FROM MOLECULAR HARTREE-FOCK THEORY. Proc Natl Acad Sci U S A 2006; 53:1089-91. [PMID: 16591272 PMCID: PMC301377 DOI: 10.1073/pnas.53.5.1089] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
|
20
|
Abstract
We measured rate constants of thermal, interfacial electron transfer through oligophenylenevinylene bridges between a gold electrode and a tethered redox species in contact with an aqueous electrolyte using the indirect laser-induced temperature jump technique. Analysis of the distance dependence indicates that, unlike other bridges studied to date, the rate constants are not limited by electronic coupling for bridges up to 28 angstroms long. The energy levels of the bridges relative to those of the redox species rule out hopping through the bridge. We conclude that, out to 28 angstroms, the transfer is limited by structural reorganization and that electron tunneling occurs in less than 20 picoseconds, suggesting that oligophenylenevinylene bridges could be useful for wiring molecular electronic elements.
Collapse
|
21
|
Electronic structure and magnetic coupling in copper oxide superconductors. PHYSICAL REVIEW. B, CONDENSED MATTER 1992; 46:11935-11951. [PMID: 10003091 DOI: 10.1103/physrevb.46.11935] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/12/2023]
|
22
|
|
23
|
A model conformational study of nucleic acid phosphate ester bonds. The torsional potential of dimethyl phosphate monoanion. J Am Chem Soc 1973; 95:256-8. [PMID: 4682894 DOI: 10.1021/ja00782a055] [Citation(s) in RCA: 94] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
|